FAMECO GENRAL CONTRACTING LLC

PROJECT: B3P RUWAIS Monthly Blasting & Painting Inspection

Subject Project Contract no

Monthly blasting/painting blasting/pain ting inspection report B3P-Ruwais

Mechanic:

Report no

pp-12-7-7777

Date Inspected by

4  August, 2012 M.TAYYAB (HSEO)

Unit no:

satisfactory

1 2

  r   o    t   a   r    i   p   s   e    R

3 4 5 6 7 8 9 10 1

  s   e    i   r   o   s   s   e   c   c   a    &   r   e   p   o   o    H    /   r   o   s   s   e   r   p   m   o    C

2 3

4 5

6 7 8 9

1

   l   a   r   e   n   e    G

2 3 4

th

Air filter for compressed air under maintenance schedule (replacement for every 3 months)? Regulator, air pressure gauge & pressure relief valve of in good condition? Air pressure of filter maintained as per the requirement of respirator in use (80-90psi)? Moister is drained from filter every four hours? Respirator lenses clean and free from cuts, abrasion? Air hose fitted with cool air tube/climate control tube? Breathing hose in good condition, free from cuts, abrasion? Blasting & painting helmet available with chin strap, suspension & cap? The helmet, hose, air entry ports & fittings checked for dust & debris? User undergone respiratory protection training? Compressor located away from exhaust of other machines, toxic source and from any other source of combustion? No vehicle around compressor air intake Air hose length kept as short as practicabl e and straight line, sharp bends avoided, and free from soft spots, cuts etc? Remote control attached with blasting nozzle Safety pins & safety cables installed at every coupling connection to prevent accidental disengagement during hose movement? Gaskets of coupling checked for wear, distortion & softness (no leakage from coupling)? Air discharge pressure gauge, air discharge temperature gauge is available in good working condition? Grounding/ Earthing done for compressor/ hooper to eliminate static electricity hazards? Is there any oil spillage containment beneath the compressor unit?



Affected zone of blasting & painting including equipment barricaded suitably and warning signs posted to warn unauthorized entry? Is paints are mixed in spate shade, away from source of ignition? Are people other than operator & painter were given suitable type of respirator? Are they trained? Is eye wash available with the unit/ nearest location?



Prepared by: M.TAYYAB (HSEO)

Need improvement

comments





√ √







√ √

√ √

√ √







√ 

Maintenance Strongly recommended







Eye wash station required

View more...