User note The following notes are typical notes to tenderers reproduced from typical bills of quantities to show possible ways of describing such notes. Users must take special care that only notes relevant to the specific project are to be included and that descriptions should be adapted as necessary to suit the particular circumstances

NOTES TO TENDERERS 1 NAMES OF PARTIES Employer ? Principal agent ? Architects ? Quantity surveyors ? Consulting structural engineers ? Consulting civil engineers ? Consulting electrical engineers ? Consulting mechanical engineers ?

2 SCOPE OF CONTRACT The description hereunder is a general guide only and the tenderer is referred to the architect#s drawings for tender purposes. No liability will be accepted should the following short description be misconstrued The contract is for a new ? The scope of the work generally comprises the following: ?

3 TENDER ENQUIRIES All tender enquiries to be directed to Mr ? (principal agent, quantity surveyor, etc?) at telephone number (?) ?

4 ACQUANTANCE WITH TENDER DOCUMENTS ETC By submission of a tender the tenderer will be deemed to have acquainted himself/herself fully with the tender documents, local authority requirements and by-laws, National Home Builders Registration Council (NHBRC) enrolment fees and all aspects of the work envisaged in the documents prior to pricing and submission of his/her tender

Notes to Tenderers ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-1-

24/02/2006 10:50:51 AM

5 SIGNING OF TENDER The tender must be signed by the tenderer or by a representative of the tenderer being duly authorised to do so and the tenderer is to attach a company resolution if applicable

6 COSTS INCURRED BY THE TENDERER The employer will not be responsible for or pay for expenses or losses which may be incurred by the tenderer in the preparation of the tender or in visiting the site

7 ACCEPTANCE OF TENDER The employer is not bound to accept the lowest or any tender nor to give any reason for the rejection of any tender

8 BLACK ECONOMIC EMPOWERMENT Tenderers must complete the questionnaire and hand it in with their tender

9 OCCUPATIONAL HEALTH AND SAFETY ACT - CONTRACT AND SPECIFICATION Tenderers must carefully study the project specification and ensure that all of the obligations, requirements and specifications are included in the tender sum

10 INFORMATION TO BE PROVIDED BY TENDERERS Tenderers are to provide the following information/documentation together with the tender submission: -

Priced bills of quantities and form of tender

-

Questionnaire: Black Economic Empowerment

-

Information required schedule

-

A tax clearance certificate stating that the tenderer#s taxes are not in arrears - this is also required for each of the members of a joint venture in such case

11 ESCALATION Two tenders are called for namely Alternative 1 and Alternative 2 Alternative 1 - Subject to CPAP (Haylett) escalation Alternative 2 - Fixed price escalation

Notes to Tenderers ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-2-

24/02/2006 10:50:51 AM

12 ESCALATION AND COMPLETION DATES Two tenders are called for namely Alternative 1 and Alternative 2. Both alternatives to include for fixed price escalation. The difference between Alternative 1 and 2 is the completion dates. The dates for Alternative 2 are annexed at the back of the tender form for Alternative 2

13 SITE INSPECTION A compulsory? site meeting and inspection tour of the work area will be held at ? on ? Tenderers are to meet at ?

14 CLOSING DATE OF TENDERS Tenders must be handed in at the offices of (principal agent, quantity surveyor, etc?) situated at ? by not later than (time and date?) Tenders are to be submitted in sealed envelopes marked #Tender for ?#

Notes to Tenderers ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-3-

24/02/2006 10:50:51 AM

Item No

Quantity

3583

BILL NO 1

3584

PRELIMINARIES

3585

BUILDING AGREEMENT AND PRELIMINARIES

3586

The JBCC Series 2000 Principal Building Agreement (March 2005 edition) prepared by the Joint Building Contracts Committee shall be the applicable building agreement, amended as hereinafter described

3587

The JBCC Series 2000 Preliminaries (May 2005 edition) prepared by the Joint Building Contracts Committee for use with the said JBCC Principal Building Agreement shall be deemed to be incorporated in these bills of quantities

3588

Contractors are referred to the above mentioned documents for the full intent and meaning of each clause thereof

3589

These clauses are hereinafter referred to by clause number and heading only. Where standard clauses or alternatives are not entirely applicable to this contract such modifications, corrections or supplements as will apply are given under each relevant clause heading and such modifications, corrections or supplements shall take precedence notwithstanding anything contrary contained in the above mentioned documents

3590

Where any item is not relevant to this specific contract such item is marked N/A, signifying "not applicable"

3591

PREAMBLES FOR TRADES

3592

The Model Preambles for Trades (1999 edition) as published by the Association of South African Quantity Surveyors shall be deemed to be incorporated in these bills of quantities and no claim arising from brevity of description of items fully described in the said Model Preambles will be entertained

3593

Supplementary preambles are incorporated in these bills of quantities to satisfy the requirements of this project. Such supplementary preambles shall take precedence over the provisions of the said Model Preambles

3594

The contractor's prices for all items throughout these bills of quantities must take account of and include for all of the obligations, requirements and specifications given in the said Model Preambles and in any supplementary preambles

Amount

PRICING OF PRELIMINARIES Should the contractor select Option A in terms of clause 10.3 for the purpose of adjustment of these preliminaries, the amount entered in the amount column in these preliminaries is to be divided into one or more of the three categories provided namely Fixed (F), Value Related (V) and Time Related (T) 3597

SECTION A - PRINCIPAL BUILDING AGREEMENT

Carried forward Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-4-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

R

Not Priced

Definitions 3599

Clause 1.0 - Definitions and interpretation

3600

F:........................ V:........................ T:.......................

3601

Objective and preparation

3602

Clause 2.0 - Offer, acceptance and performance

3603

F:........................ V:........................ T:.......................

3604

Clause 3.0 - Documents

3605

F:........................ V:........................ T:.......................

3606

Clause 4.0 - Design responsibility

3607

F:........................ V:........................ T:.......................

3608

Clause 5.0 - Employer's agents

3609

F:........................ V:........................ T:.......................

3610

Clause 6.0 - Site representative

3611

F:........................ V:........................ T:.......................

3612

Clause 7.0 - Compliance with regulations

3613

User note

3614

Insert the following where a health and safety specification is not yet available

3615

?Without limiting the generality of the provisions of clause 7.0 the contractor's attention is drawn to the provisions of the Construction Regulations, 2003 issued in terms of the Occupational Health and Safety Act, 1993. It is specifically stated that the employer shall prepare a documented health and safety specification for the works and that the employer shall ensure that the contractor has made provision for the cost of health and safety measures during the execution of the works. The contractor shall price opposite this item for compliance with the act and the regulations and the reasonable provisions of the afore mentioned health and safety specification?

3616

User note

3617

Insert the following where a health and safety specification is available

Carried forward Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-5-

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

3618

?Without limiting the generality of the provisions of clause 7.0 the contractor's attention is drawn to the provisions of the Construction Regulations, 2003 issued in terms of the Occupational Health and Safety Act, 1993. It is specifically stated that the employer shall prepare a documented health and safety specification for the works (refer to Annexure ? for a copy of the relevant specification) and that the employer shall ensure that the contractor has made provision for the cost of health and safety measures during the execution of the works. The contractor shall price opposite this item for compliance with the act and the regulations and the reasonable provisions of the afore mentioned health and safety specification?

3619

User note

3620

Insert the following for residential developments only

3621

?The contractor shall allow for and pay any levies required by the National Home Builders Registration Council (NHBRC)?

3622

F:........................ V:........................ T:.......................

3623

Clause 8.0 - Works risk

3624

F:........................ V:........................ T:.......................

3625

Clause 9.0 - Indemnities

3626

F:........................ V:........................ T:.......................

3627

Clause 10.0 - Works insurances

3628

F:........................ V:........................ T:.......................

3629

Clause 11.0 - Liability insurances

3630

F:........................ V:........................ T:.......................

3631

Clause 12.0 - Effecting insurances

3632

F:........................ V:........................ T:.......................

3633

Clause 13.0 - No clause

N/A

3634

Clause 14.0 - Security

Item

Not Priced

3635

F:........................ V:........................ T:.......................

3636

Execution

3637

Clause 15.0 - Preparation for and execution of the works

Item

Not Priced

R

Not Priced

Carried forward Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-6-

24/02/2006 10:50:51 AM

Brought forward 3638

F:........................ V:........................ T:.......................

3639

Clause 16.0 - Access to the works

3640

F:........................ V:........................ T:.......................

3641

Clause 17.0 - Contract instructions

3642

F:........................ V:........................ T:.......................

3643

Clause 18.0 - Setting out of the works

3644

The contractor shall notify the principal agent if any encroachments of adjoining foundations, buildings, structures, pavements, boundaries, etc exist in order that the necessary arrangements may be made for the rectification of any such encroachments

3645

F:........................ V:........................ T:.......................

3646

Clause 19.0 - Assignment

3647

F:........................ V:........................ T:.......................

3648

Clause 20.0 - Nominated subcontractors

3649

F:........................ V:........................ T:.......................

3650

Clause 21.0 - Selected subcontractors

3651

F:........................ V:........................ T:.......................

3652

Clause 22.0 - Employer's direct contractors

3653

F:........................ V:........................ T:.......................

3654

Clause 23.0 - Contractor's domestic subcontractors

3655

F:........................ V:........................ T:.......................

R

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

R

Not Priced

Completion 3657

Clause 24.0 - Practical completion

3658

F:........................ V:........................ T:.......................

3659

Clause 25.0 - Works completion

3660

F:........................ V:........................ T:.......................

Carried forward Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-7-

24/02/2006 10:50:51 AM

Brought forward 3661

Clause 26.0 - Final completion

3662

F:........................ V:........................ T:.......................

3663

Clause 27.0 - Latent defects liability period

3664

F:........................ V:........................ T:.......................

3665

Clause 28.0 - Sectional completion

3666

F:........................ V:........................ T:.......................

3667

Clause 29.0 - Revision of the date for practical completion

3668

The removal and replacement of materials and/or workmanship which do not conform to specification or drawings shall not constitute grounds for an extension of the construction period nor for an adjustment to the contract value (clause 29.3)

3669

F:........................ V:........................ T:.......................

3670

Clause 30.0 - Penalty for noncompletion

3671

F:........................ V:........................ T:.......................

R

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

R

Not Priced

Payment 3673

Clause 31.0 - Interim payment to the contractor

3674

?The inclusion of materials and goods stored off site in the amount authorised for payment in terms of clause 31.4 shall be at the sole discretion of the principal agent and such inclusion shall only be considered upon the provision, by the contractor, of an approved guarantee issued by a registered commercial bank. Clause 31.6.5 is therefore not applicable? ?Materials and goods stored off site shall not be included in the amount authorised for payment?

3676

F:........................ V:........................ T:.......................

3677

Clause 32.0 - Adjustment to the contract value

3678

?All fluctuations in costs, with the exception of fluctuations in the rate of Value Added Tax, shall be for the account of the contractor?

Carried forward Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-8-

24/02/2006 10:50:51 AM

Brought forward 3679

?Where prices are submitted by the contractor or nominated/selected subcontractors during the progress of the works in respect of contract instructions or in regard to a claim under the terms of the contract and notwithstanding the fact that such prices may be used in an interim payment certificate, there is to be no presumption of acceptance. Should the principal agent wish to accept any such prices prior to the issue of the final certificate, it will be in writing?

3680

F:........................ V:........................ T:.......................

3681

Clause 33.0 - Recovery of expense and loss

3682

F:........................ V:........................ T:.......................

3683

Clause 34.0 - Final account and final payment

3684

F:........................ V:........................ T:.......................

3685

Clause 35.0 - Payment to other parties

3686

F:........................ V:........................ T:.......................

3687

Cancellation

3688

Clause 36.0 - Cancellation by employer - contractor's default

3689

F:........................ V:........................ T:.......................

3690

Clause 37.0 - Cancellation by employer - loss and damage

3691

F:........................ V:........................ T:.......................

3692

Clause 38.0 - Cancellation by contractor - employer's default

3693

F:........................ V:........................ T:.......................

3694

Clause 39.0 - Cancellation - cessation of the works

3695

F:........................ V:........................ T:.......................

3696

Dispute

3697

Clause 40.0 - Dispute settlement

3698

F:........................ V:........................ T:.......................

3699

Substitute provisions

3700

Clause 41.0 - State clauses

Carried forward Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-9-

R

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 3701

R

Not Priced

Item

Not Priced

R

Not Priced

F:........................ V:........................ T:....................... Contract variables

3703

Clause 42.0 - Pre-tender information

3704

Information necessary for the completion of those clauses contained in the schedule which are necessary for tender purposes is given hereunder

3705

42.1

3706

42.1.1 Employer: ........................................................ Postal address: ................................................ ..............................................Code: ................ Tel: ............................Fax: .............................. E-mail: ............................................................. Tax/VAT registration No: .................................. Physical address: ............................................. ........................................................................ ........................................................................

3707

42.1.2 Principal agent: .................................................. Postal address: .................................................. .............................................. Code: .................. Tel: ............................Fax: ................................ E-mail: ..............................................................

3708

42.1.3 Agent (1) ............................................................. Agent's service: ................................................... Postal address: ................................................... ..............................................Code: ................... Tel: ............................Fax: ................................. E-mail: ...............................................................

CONTRACTING AND OTHER PARTIES

42.1.4 Agent (2) ............................................................. Agent's service: ................................................... Postal address: ................................................... ..............................................Code: ................... Tel: ............................Fax: ................................. E-mail: ...............................................................

3710

42.1.5 Agent (3) ............................................................. Agent's service: ................................................... Postal address: ................................................... ..............................................Code: ................... Tel: ............................Fax: ................................. E-mail: ...............................................................

Carried forward Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-10-

24/02/2006 10:50:51 AM

3711

42.1.6 Agent (4) ............................................................. Agent's service: ................................................... Postal address: ................................................... ..............................................Code: ................... Tel: ............................Fax: ................................. E-mail: ...............................................................

3712

42.1.7 Agent (5) ............................................................. Agent's service: ................................................... Postal address: ................................................... ..............................................Code: ................... Tel: ............................Fax: ................................. E-mail: ...............................................................

3713

42.1.8 Agent (6) ............................................................. Agent's service: ................................................... Postal address: ................................................... ..............................................Code: ................... Tel: ............................Fax: ................................. E-mail: ...............................................................

3714

42.1.9 Agent (7) ............................................................. Agent's service: ................................................... Postal address: ................................................... ..............................................Code: ................... Tel: ............................Fax: ................................. E-mail: ...............................................................

3715

42.2

3716

42.2.1 Works description: ............................................... ........................................................................... ........................................................................... ...........................................................................

Brought forward

R

Not Priced

Carried forward

R

Not Priced

CONTRACT DETAILS

42.2.2 Site description: .................................................. .......................................................................... .......................................................................... .......................................................................... 42.2.3 Work or installations by direct contractors ............. ........................................................................... ........................................................................... ........................................................................... ........................................................................... ........................................................................... ........................................................................... ...........................................................................

Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-11-

24/02/2006 10:50:51 AM

Brought forward 3719

42.2.4 Specific options that are applicable to a state organ only Where so: (1) Interest rate legislation: ............................... (2) Lateral support insurance to be effected by the contractor ? yes/no ? (3) Payment will be made for materials and goods ? yes/no ? (4) Dispute resolution by litigation ? yes/no ? (5) Extended defects liability period applicable to the following elements: ................................ ...................................................................... ...................................................................... ...................................................................... ...................................................................... ......................................................................

3720

42.2.5 Possession of the site is intended to be given on ..............................................................

R

Not Priced

R

Not Priced

(date)

42.2.6 Period for the commencement of the works after the contractor takes possession of the site (No of working days) ....................................... 42.2.7 For the works as a whole: The date for practical completion and the penalty per calendar day Date ............................. Penalty R....................... 3723

42.2.8 For the works in sections: The date for practical completion and the penalty per calendar day Section 1 Date .................... Penalty R.................. Section 2 Date .................... Penalty R.................. Section 3 Date .................... Penalty R.................. Section 4 Date .................... Penalty R.................. Section 5 Date .................... Penalty R ................. Section 6 Date .................... Penalty R .................

3724

42.2.9 The law applicable to this agreement shall be that of (country) .........................................................

3725

42.3

3726

42.3.1 Contract works insurance to be effected by ? employer ? contractor ? For the sum of: R ................................... With a deductible of: R ...................................

INSURANCES

Carried forward Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-12-

24/02/2006 10:50:51 AM

Brought forward 3727

42.3.2 Supplementary insurance is required - ? yes/no ? If "yes" state requirement ..................................

3728

42.3.3 Public liability insurance to be effected by ? employer ? contractor ? For the sum of: R..................................... With a deductible of: R.....................................

3729

42.3.4 Support insurance to be effected by employer For the sum of: R..................................... With a deductible of: R.....................................

3730

42.4

3731

42.4.1 Waiver of the contractor's lien or right of continuing posession is required - ? yes/no ?

3732

42.4.2 Construction document copies to be supplied to the contractor free of charge (No of .......)

3733

42.4.3 State measuring system used for drawing up bills of quantities (lump sum document?) ..................... ..........................................................................

3734

42.4.4 Number of working days for submission of priced documents (No of .......)

3735

42.4.5 JBCC Engineering General Conditions are to be included in the contract documents -

R

Not Priced

R

Not Priced

DOCUMENTS

? yes/no ? 3736

42.4.6 The contract value is to be adjusted using CPAP

indices ? yes/no ?

Where CPAP is to be used (base month) ............ Alternative indices (if applicable) .........................

Carried forward Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-13-

24/02/2006 10:50:51 AM

Brought forward 3737

42.4.7 Details of changes made to the provisions of JBCC standard documentation - ................. ...................................................................... ...................................................................... ...................................................................... ...................................................................... ...................................................................... ...................................................................... ...................................................................... ...................................................................... ...................................................................... ...................................................................... ...................................................................... ...................................................................... ...................................................................... ...................................................................... ......................................................................

3738

Clause 42.0 - Post-tender information

3739

The required post-tender information shall be inserted in the agreement after consultation with the contractor

3740

User note

3741

All information for this section requires consultation with the contractor. The principal agent should not pre-select any of the alternatives available to the contractor

3742

SECTION B - PRELIMINARIES

3743

Definitions and interpretation

3744

Clause 1.0 - Definitions and interpretation

3745

F:........................ V:........................ T:.......................

3746

Documents

3747

Clause 2.1 - Checking of documents

3748

F:........................ V:........................ T:.......................

3749

Clause 2.2 - Provisional bills of quantities

R

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

R

Not Priced

?These bills of quantities are in multiple procurement format ie the "wet trades" earthworks, concrete, formwork and reinforcement, precast concrete, masonry, waterproofing and subsurface drainage - are provisionally (fully?) measured, with the subsequent trades being budgetary allowances and/or ?selected? (nominated?) subcontract amounts?

Carried forward Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-14-

24/02/2006 10:50:51 AM

Brought forward 3751

F:........................ V:........................ T:.......................

3752

User note

R

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

R

Not Priced

Check wet trades included in the bills of quantities 3754

Clause 2.3 - Availability of construction documentation ?The budgetary allowances and ?selected? (nominated?) subcontract amounts allocated for subsequent trades included in this document will be separately procured, based on multiple procurement of ?selected? (nominated?) subcontractors during the construction period?

3756

F:........................ V:........................ T:.......................

3757

Clause 2.4 - Interests of agents

3758

F:........................ V:........................ T:.......................

3759

Clause 2.5 - Priced documents

3760

F:........................ V:........................ T:.......................

3761

Clause 2.6 - Tender submission ?Tenders shall be valid for a period of ? days from the closing date of tenders?

3763

F:........................ V:........................ T:.......................

3764

The site

3765

Clause 3.1 - Defined works area

3766

?The area of the works to be occupied by the contractor is indicated on architect's drawing No(s)? ?

3767

F:........................ V:........................ T:.......................

3768

Clause 3.2 - Geotechnical investigation

3769

?No geotechnical investigation report is available? ?A copy of the geotechnical investigation report is annexed to these bills of quantities?

3771

F:........................ V:........................ T:.......................

3772

Clause 3.3 - Inspection of the site

3773

F:........................ V:........................ T:.......................

Carried forward Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-15-

24/02/2006 10:50:51 AM

Brought forward 3774

Clause 3.4 - Existing premises occupied

3775

F:........................ V:........................ T:.......................

3776

Clause 3.5 - Previous work - dimensional accuracy

3777

F:........................ V:........................ T:.......................

3778

Clause 3.6 - Previous work - defects

3779

F:........................ V:........................ T:.......................

3780

Clause 3.7 - Services - known

3781

F:........................ V:........................ T:.......................

3782

Clause 3.8 - Services - unknown

3783

F:........................ V:........................ T:.......................

3784

Clause 3.9 - Protection of trees

3785

F:........................ V:........................ T:.......................

3786

Clause 3.10 - Articles of value

3787

F:........................ V:........................ T:.......................

3788

Clause 3.11 - Inspection of adjoining properties

3789

F:........................ V:........................ T:.......................

3790

Management of contract

3791

Clause 4.1 - Management of the works

3792

F:........................ V:........................ T:.......................

3793

Clause 4.2 - Programme for the works

3794

F:........................ V:........................ T:.......................

3795

Clause 4.3 - Progress meetings

3796

F:........................ V:........................ T:.......................

3797

Clause 4.4 - Technical meetings

3798

F:........................ V:........................ T:.......................

Carried forward Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-16-

R

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 3799

Clause 4.5 - Labour and plant records

3800

F:........................ V:........................ T:.......................

3801

Samples, shop drawings and manufacturer's instructions

3802

Clause 5.1 - Samples of materials

3803

F:........................ V:........................ T:.......................

3804

Clause 5.2 - Workmanship samples

3805

F:........................ V:........................ T:.......................

3806

Clause 5.3 - Shop drawings

3807

F:........................ V:........................ T:.......................

3808

Clause 5.4 - Compliance with manufacturers' instructions

3809

F:........................ V:........................ T:.......................

3810

Temporary works and plant

3811

Clause 6.1 - Deposits and fees

3812

F:........................ V:........................ T:.......................

3813

Clause 6.2 - Enclosure of the works

3814

F:........................ V:........................ T:.......................

3815

Clause 6.3 - Advertising

3816

F:........................ V:........................ T:.......................

3817

Clause 6.4 - Plant, equipment, sheds and offices

3818

F:........................ V:........................ T:.......................

3819

Clause 6.5 - Main noticeboard

3820

F:........................ V:........................ T:.......................

3821

Clause 6.6 - Subcontractors' noticeboard

3822

F:........................ V:........................ T:.......................

Carried forward Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-17-

R

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 3823

Temporary services

3824

Clause 7.1 - Location

3825

F:........................ V:........................ T:.......................

3826

Clause 7.2 - Water

3827

F:........................ V:........................ T:.......................

3828

Clause 7.3 - Electricity

3829

F:........................ V:........................ T:.......................

3830

Clause 7.4 - Telecommunication facilities

3831

F:........................ V:........................ T:.......................

3832

Clause 7.5 - Ablution facilities

3833

F:........................ V:........................ T:.......................

3834

Prime cost amounts

3835

Clause 8.1 - Responsibility for prime cost amounts

3836

F:........................ V:........................ T:.......................

3837

Attendance on nominated/selected subcontractors

3838

Clause 9.1 - General attendance

3839

F:........................ V:........................ T:.......................

3840

Clause 9.2 - Special attendance

3841

F:........................ V:........................ T:.......................

3842

Clause 9.3 - Commissioning - fuel, water and electricity

3843

F:........................ V:........................ T:.......................

3844

Financial aspects

3845

Clause 10.1 - Statutory taxes, duties and levies

3846

Provision is made in the summary of these bills of quantities for the inclusion of Value Added Tax (VAT)

Carried forward Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-18-

R

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 3847

F:........................ V:........................ T:.......................

3848

Clause 10.2 - Payment of preliminaries

3849

F:........................ V:........................ T:.......................

3850

Clause 10.3 - Adjustment of preliminaries

3851

Should the contractor select Option B but fail to provide the information required prior to the signing of the contract, the principal agent shall have the right to select either Option A or B for the adjustment of preliminaries. If the principal agent selects Option B he shall be entitled to make assumptions at his discretion regarding the information which the contractor would normally have provided prior to the signing of the contract

3852

F:........................ V:........................ T:.......................

3853

Clause 10.4 - Payment certificate cash flow

3854

F:........................ V:........................ T:.......................

3855

General

3856

Clause 11.1 - Protection of the works

3857

F:........................ V:........................ T:.......................

3858

Clause 11.2 - Protection/isolation of existing/sectionally occupied works

3859

F:........................ V:........................ T:.......................

3860

Clause 11.3 - Security of the works

3861

F:........................ V:........................ T:.......................

3862

Clause 11.4 - Notice before covering work

3863

F:........................ V:........................ T:.......................

3864

Clause 11.5 - Disturbance

3865

F:........................ V:........................ T:.......................

3866

Clause 11.6 - Environmental disturbance

3867

?A copy of the environmental management plan is annexed to these bills of quantities. The contractor shall comply with all the requirements of such environmental management plan?

3868

F:........................ V:........................ T:.......................

Carried forward Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-19-

R

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 3869

Clause 11.7 - Works cleaning and clearing

3870

F:........................ V:........................ T:.......................

3871

Clause 11.8 - Vermin

3872

F:........................ V:........................ T:.......................

3873

Clause 11.9 - Overhand work

3874

F:........................ V:........................ T:.......................

3875

Clause 11.10 - Instruction manuals and guarantees

3876

F:........................ V:........................ T:.......................

3877

Clause 11.11 - As built information

3878

F:........................ V:........................ T:.......................

3879

Clause 11.12 - Tenant installations

3880

F:........................ V:........................ T:.......................

R

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

R

Not Priced

Schedule of variables 3882

12.1 - Pre-tender information

3883

Information necessary for elections and completion of those clauses contained in the schedule which are necessary for tender purposes is given hereunder. Where no information is given it shall mean that either specific requirements are not required or that the clause is not relevant to this specific contract

3884

12.1.1 - Provisional bills of quantities [clause 2.2]

3885

The quantities are provisional - ? yes/no ?

3886

12.1.2 - Availability of construction documentation [clause 2.3]

3887

Construction documentation is complete - ? yes/no ?

3888

12.1.3 - Interests of agents [clause 2.4]

3889

12.1.4 - Defined works area [clause 3.1]

3890

12.1.5 - Geotechnical investigation [clause 3.2]

3891

12.1.6 - Existing premises occupied [clause 3.4]

Carried forward Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-20-

24/02/2006 10:50:51 AM

Brought forward 3892

12.1.7 - Previous work - dimensional accuracy [clause 3.5]

3893

12.1.8 - Previous work - defects [clause 3.6]

3894

12.1.9 - Services - known [clause 3.7]

3895

12.1.10 - Protection of trees [clause 3.9]

3896

12.1.11 - Inspection of adjoining properties [clause 3.11]

3897

12.1.12 - Enclosure of the works [clause 6.2]

3898

12.1.13 - Offices [clause 6.4.3]

3899

12.1.14 - Main noticeboard [clause 6.5]

3900

12.1.15 - Subcontractors' noticeboard [clause 6.6]

3901

A noticeboard is required - ? yes/no ?

3902

12.1.16 - Water [clause 7.2]

3903

Option A (by contractor) ? yes/no ? Option B (by employer - free of charge) ? yes/no ? Option C (by employer - metered) ? yes/no ?

3904

12.1.17 - Electricity [clause 7.3]

R

Not Priced

R

Not Priced

Option A (by contractor) ? yes/no ? Option B (by employer - free of charge) ? yes/no ? Option C (by employer - metered) ? yes/no ?

3906

12.1.18 - Telecommunications [clause 7.4]

3907

Telephone Facsimile E-mail

3908

12.1.19 - Ablution facilities [clause 7.5]

3909

Option A (by contractor) ? yes/no ? Option B (by employer) ? yes/no ?

3910

12.1.20 - Protection/isolation of existing/sectionally occupied works [clause 11.2]

3911

Protection/isolation is required - ? yes/no ?

3912

12.1.21 - Special attendance [clause 9.2]

? yes/no ? ? yes/no ? ? yes/no ?

Carried forward Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-21-

24/02/2006 10:50:51 AM

Brought forward 3913

12.1.22 - Protection of the works [clause 11.1]

3914

12.1.23 - Disturbance [clause 11.5]

3915

12.1.24 - Environmental disturbance [clause 11.6]

3916

12.2 - Post-tender information

3917

The required post-tender information shall be inserted in the preliminaries after consultation with the contractor

3918

User note

3919

All information for this section requires consultation with the contractor. The principal agent should not pre-select any of the alternatives available to the contractor

3920

SECTION C - SPECIFIC PRELIMINARIES

3921

User note

3922

Selected examples of typical clauses are provided to show possible ways of describing such clauses. Users must delete, adapt or add to these examples to suit their particular circumstances

3923

Site instructions

3924

Site instructions issued on site are to be recorded in triplicate in a site instruction book which is to be provided and maintained on site by the contractor

3925

F:........................ V:........................ T:.......................

3926

Warranties for materials and workmanship

3927

Where warranties for materials are called for, the contractor shall obtain a written warranty, addressed to the employer, from the firm supplying the materials and/or doing the work and shall deliver same to the principal agent on the certified completion of the contract. The warranty shall state that workmanship, materials and installation are warranteed for a specified period from the date of certified completion of the contract, and that any defects that may arise during the specified period shall be made good at the expense of the firm supplying the materials and/or doing the work, upon written notice to do so. The warranty will not be enforced if the work is damaged by defects in the construction of the building in which case the responsibility for replacement shall rest entirely with the contractor.

3928

F:........................ V:........................ T:.......................

3929

Co-operation of contractor for cost management

Carried forward Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-22-

R

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 3930

It is specifically agreed that the contractor accepts the obligation of assisting the principal agent in implementing proper cost management. The contractor will be advised by the principal agent of all cost management procedures which will be implemented to ensure that the final building cost does not exceed the budget. The principal agent undertakes to make available to the contractor all budgetary allowances and cost assessments/reports to enable the proper procedures to be implemented and the contractor shall attend all cost plan review and cost management meetings. The contractor undertakes to extend these procedures, as necessary, to all subcontractors

3931

F:........................ V:........................ T:.......................

3932

Confidentiality

3933

The contractor undertakes to maintain in confidence any and all information regarding this project and shall obtain appropriate similar undertakings from all subcontractors and suppliers. Such information shall not be used in any way except in connection with the execution of the works

R

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

Item

Not Priced

R

Not Priced

No information regarding this project shall be published or disclosed without the prior written consent of the employer 3934

F:........................ V:........................ T:.......................

3935

Propping of floors below

3936

The contractor is advised that propping of floors below may be required if he wishes to use any areas of completed suspended reinforced concrete slabs for vehicle access, storage of materials and goods and location of plant, scaffolding, etc. The location of these areas and any necessary propping shall be approved by the principal agent and the cost thereof shall be borne by the contractor

3937

F:........................ V:........................ T:.......................

3938

Testing of windows for watertightness

3939

Each window shall be tested for watertightness with water sprayed on by means of a 20mm hosepipe using adequate pressure. If in the opinion of the principal agent, the pressure proves to be inadequate, then the pressure in the hosepipe shall be boosted by means of compressed air or other approved means

3940

F:........................ V:........................ T:.......................

3941

Testing of flat roof waterproofing for watertightness

Carried forward Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-23-

24/02/2006 10:50:51 AM

Brought forward 3942

Flat roof waterproof areas shall be prepared with small sand dykes around them of a size and enclosing an area approved by the principal agent, flooded with water and kept "ponded" for at least 36 hours as a test to ensure the watertightness of the waterproofing and before any further construction work is carried out above the waterproofing

3943

F:........................ V:........................ T:.......................

3944

SUMMARY OF CATEGORIES

3945

Category: Fixed F:..............................

R

Not Priced

R

Not Priced

Category: Value V:.............................. Category: Time T:................................

Carried to summary Bill No 1 Preliminaries ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-24-

24/02/2006 10:50:51 AM

Item No 2837

Unit

Quantity

Rate

Amount

BILL NO ? ALTERATIONS

2839

SUPPLEMENTARY PREAMBLES

2840

View site

2841

Before submitting his tender the contractor shall visit the site and satisfy himself as to the nature and extent of the work to be done and the value of the materials contained in the buildings or portions of the buildings to be demolished. No claim for any variations of the contract sum in respect of the nature and extent of the work or of inferior or damaged materials will be entertained

2842

Explosives

2843

No explosives whatsoever may be used for demolition purposes unless otherwise stated

2844

General

2845

The contractor shall carry out the whole of the works with as little mess and noise as possible and with a minimum of disturbance to adjoining premises and their tenants. He shall provide proper protection and provide, erect and remove when directed, any temporary tarpaulins that may be necessary during the progress of the works, all to the satisfaction of the principal agent

2846

Water supply pipes and other piping that may be encountered and found necessary to disconnect or cut, shall be effectually stopped off or grubbed up and removed, and any new connections that may be necessary shall be made with proper fittings, to the satisfaction of the principal agent

2847

Doors, fanlights, fittings, frames, linings, etc which are to be re-used shall be thoroughly overhauled before refixing including taking off, easing and rehanging, cramping up, re-wedging as required and making good cramps, dowels, etc, and easing, oiling, adjusting and repairing ironmongery as necessary, replacing any glass damaged in removal or subsequently and stopping up all nail and screw holes with tinted plastic wood to match timber, unless otherwise described. Re-painting or re-varnishing is given separately

2848

Prices for taking out of doors, windows, etc shall include for removal of all beads, architraves, ironmongery, etc

Carried forward Bill No 2 Alterations ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-25-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2849

Prices for taking out and removing doors and frames shall include for removing door stops, cabin hooks, etc and making good floor and wall finishes to match existing

2850

With regard to building up of openings in existing walls, cement screeds and pavings, granolithic, tops of walls, etc, shall be levelled and prepared for raising of brickwork

2851

Making good of finishes shall include making good of the brick and concrete surfaces onto which the new finishes are applied, where necessary

2852

The contractor will be required to take all dimensions affecting the existing buildings on the site and he will be held solely responsible for the accuracy of all such dimensions where used in the manufacture of new items (doors, windows, fittings, etc)

2853

TEMPORARY BARRIERS, SCREENS, ETC

R

Not Priced

Temporary barriers, screens, etc including removal 2855

2856

2857

2858

Half brick barrier wall ?m high, including cement plaster and two coats interior quality PVA emulsion paint on one side

m

Not Priced

Dust screen ?m high between concrete floor and ceiling, of suitable timber framing with 375 micron polyethylene sheeting stapled on on one side, including corners, ends, etc

m

Not Priced

Drywall barrier ?m high of galvanised steel channel section rails and studs covered on one side with 12,7mm gypsum plasterboard and finished with two coats interior quality PVA emulsion paint, including corners, ends, etc

m

Not Priced

Extra over for hollow core single door 813 x 2032mm high, including steel frame, two-lever mortice lock, primer and two coats paint

No

Not Priced

2859

REMOVAL OF EXISTING WORK

2860

Breaking up and removing unreinforced concrete

2861

Steps



Not Priced

2862

?mm Thick surface beds



Not Priced

Carried forward Bill No 2 Alterations ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-26-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2863

Breaking up and removing reinforced concrete, including cutting off and removing reinforcement

2864

Stairs and landings



Not Priced

2865

Beams



Not Priced

2866

Columns



Not Priced

2867

?mm Thick surface beds



Not Priced

2868

?mm Thick slabs



Not Priced

2869

? x ?m Portion of ?mm thick slab

No

Not Priced

2870

? x ?m Opening through ?mm thick slab

No

Not Priced

2871

Breaking down and removing brickwork etc

2872

Mass brickwork



Not Priced

2873

Half brick walls



Not Priced

2874

One brick walls



Not Priced

2875

?mm Hollow walls of two half brick skins



Not Priced

2876

Taking out and removing doors, windows, etc from brickwork to be demolished

2877

Taking out and removing doors, windows, etc, including thresholds, sills, etc (building up openings and making good finishes elsewhere)

2878

Timber single door and frame not exceeding 2,5m²

No

Not Priced

2879

Timber double door and frame exceeding 2,5m² and not exceeding 5m²

No

Not Priced

2880

Timber single door and steel frame not exceeding 2,5m²

No

Not Priced

2881

Timber double door and steel frame exceeding 2,5m² and not exceeding 5m²

No

Not Priced

2882

Glazed timber window not exceeding 2,5m²

No

Not Priced

2883

Glazed timber window exceeding 2,5m² and not exceeding 5m²

No

Not Priced

Carried forward Bill No 2 Alterations ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-27-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2884

R

Not Priced

Glazed timber window exceeding ?m² and not exceeding ?m²

No

Not Priced

2885

Glazed steel window not exceeding 2,5m²

No

Not Priced

2886

Glazed steel window exceeding 2,5m² and not exceeding 5m²

No

Not Priced

2887

Glazed steel window exceeding ?m² and not exceeding ?m²

No

Not Priced

2888

Roller shutter door ? x ?m high

No

Not Priced

2889

Taking out and removing doors, windows, etc, including thresholds, sills, etc and building up openings in brick walls, including making good cement plaster on ? side(s) (making good paintwork elsewhere)

2890

Timber single door and frame ? x ?m high overall from ? brick wall

No

Not Priced

Timber double door and frame ? x ?m high overall from ? brick wall

No

Not Priced

Timber single door and steel frame ? x ?m high overall from ? brick wall

No

Not Priced

Timber double door and steel frame ? x ?m high overall from ? brick wall

No

Not Priced

2894

Glazed timber window ? x ?m high from ? brick wall

No

Not Priced

2895

Glazed steel window ? x ?m high from ? brick wall

No

Not Priced

2896

Taking out doors, windows, etc, including thresholds, sills, etc, setting aside for re-use and later refixing in similar new position

2897

Timber single door and frame ? x ?m high overall, including setting up and building in frame in new brickwork, rehanging door on new ?mm brass hinges and replacing lock with "?" three-lever mortice lockset

No

Not Priced

Glazed steel window ? x ?m high, including setting up and building in in new brickwork and replacing any broken glass panes with ?mm clear float glass

No

Not Priced

2891

2892

2893

2898

Carried forward Bill No 2 Alterations ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-28-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2899

Taking down and removing roofs, floors, panelling, ceilings, partitions, etc

2900

Corrugated sheet steel roof covering and timber purlins



Not Priced

2901

Pitched roof ? x ? x ?m high overall, of timber trusses and purlins, corrugated sheet steel covering, ceilings and cornices, eaves soffit covering, fascias, barge boards, gutters and rainwater pipes

No

Not Priced

Tongued and grooved timber suspended floors, including skirtings, timber joists, bearers, etc



Not Priced

Gypsum plasterboard ceilings, including cornices, timber brandering, etc



Not Priced

Flush plastered gypsum plasterboard suspended ceilings, including cornices, suspension grid, hangers, etc



Not Priced

Acoustic tile suspended ceilings, including cornices, suspension grid, hangers, etc



Not Priced

m

Not Priced

2902

2903

2904

2905

2906

Drywall partitions ?m high, including doors, glazed borrowed lights, etc

2907

Taking out and removing sundry joinery work, fittings, etc

2908

Timber cornices

m

Not Priced

2909

Timber skirtings

m

Not Priced

2910

Timber sills

m

Not Priced

2911

Timber wall cupboard ? x ? x ?mm high

No

Not Priced

2912

Timber floor cupboard ? x ? x ?mm high

No

Not Priced

2913

Timber sink cupboard ? x ? x ?mm high, including sink and disconnecting waste pipe

No

Not Priced

2914

Timber counter ? x ? x ?mm high

No

Not Priced

2915

Taking out and removing sundry joinery work, fittings, etc, setting aside for re-use and later refixing in similar new position

2916

Timber cornices

m

Not Priced

2917

Timber skirtings

m

Not Priced

Carried forward Bill No 2 Alterations ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-29-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2918

Timber sills

2919

R

Not Priced

m

Not Priced

Timber wall cupboard ? x ? x ?mm high

No

Not Priced

2920

Timber floor cupboard ? x ? x ?mm high

No

Not Priced

2921

Timber sink cupboard ? x ? x ?mm high, including sink and disconnecting waste pipe (new trap and connecting to new waste pipe elsewhere)

No

Not Priced

2922

Timber counter ? x ? x ?mm high

No

Not Priced

2923

Taking up and removing wood block floor coverings, vinyl floor coverings, carpets, etc and preparing screeds for new floor coverings

2924

Wood block floor covering



Not Priced

2925

Vinyl tile floor covering



Not Priced

2926

Vinyl sheet floor covering with welded joints



Not Priced

2927

Carpet tile floor covering



Not Priced

2928

Taking out and removing ironmongery

2929

Mortice lockset from timber door

No

Not Priced

2930

Door closer from timber door and frame

No

Not Priced

2931

Towel rail not exceeding ?mm long from wall

No

Not Priced

2932

Toilet paper holder from wall

No

Not Priced

2933

Hat and coat hook from wall

No

Not Priced

2934

Taking out/off and removing sundry metalwork

2935

Steel pipe handrails from walls, including making good plaster finish

m

Not Priced

Steel balustrades ?mm high from concrete stairs, including making good granolithic finish

m

Not Priced

Steel staircase comprising two flights and one landing, ? x ? m overall on plan and rising ?m, including supporting columns, balustrades, etc

No

Not Priced

2936

2937

Carried forward Bill No 2 Alterations ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-30-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2938

Steel wire mesh burglar proofing with frame ? x ?m high bolted to brickwork, including making good face brickwork

R

Not Priced

No

Not Priced

2939

Hacking up/off and removing granolithic, screeds, plaster, etc from concrete or brickwork and preparing surfaces for new screed, plaster, tile finishes, etc

2940

?mm Granolithic from floors



Not Priced

2941

?mm Granolithic from treads and risers of stairs



Not Priced

2942

Granolithic skirtings ?mm high

m

Not Priced

2943

?mm Screed from floors



Not Priced

2944

?mm Screed from floors, including vinyl floor covering



Not Priced

2945

Internal plaster from walls and columns



Not Priced

2946

Internal plaster from ceilings and beams



Not Priced

2947

External plaster from walls, columns and beams



Not Priced

2948

Hacking up/off and removing ceramic tiles including removing mortar bed or adhesive from concrete or brickwork and preparing surfaces for new screed, plaster, tile finish, etc

2949

Tiles to floors



Not Priced

2950

Tiles to treads and risers of stairs



Not Priced

2951

Tiles to walls



Not Priced

2952

Tile skirtings ?mm high

m

Not Priced

2953

Taking out and removing piping, sanitary fittings, etc, including cutting off as necessary, disconnecting piping from fittings and making good floor and wall finishes (making good tiling and paintwork elsewhere)

2954

PVC (Copper? Steel?) piping not exceeding 50mm diameter

m

Not Priced

2955

PVC (Copper? Steel? Cast iron?) piping exceeding 50mm and not exceeding 100mm diameter

m

Not Priced

PVC (Steel? Cast iron?) piping exceeding ?mm and not exceeding ?mm diameter

m

Not Priced

2956

Carried forward Bill No 2 Alterations ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-31-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2957

Stainless steel wash hand basin

No

Not Priced

2958

Stainless steel wash hand basin, including short lengths of piping, etc

No

Not Priced

Stainless steel sink and drainer including timber cupboard ? x ? x ?mm high

No

Not Priced

2960

Vitreous china wash hand basin

No

Not Priced

2961

Vitreous china wash hand basin, including short lengths of piping, etc

No

Not Priced

2962

Vitreous china WC pan with cistern

No

Not Priced

2963

Vitreous china WC pan with cistern, including short lengths of piping, etc

No

Not Priced

2964

Vitreous china WC pan with flush valve

No

Not Priced

2965

Vitreous china WC pan with flush valve, including short lengths of piping, etc

No

Not Priced

2966

Vitreous china wall hung urinal with flush valve

No

Not Priced

2967

Vitreous china wall hung urinal with flush valve, including short lengths of piping, etc

No

Not Priced

Stainless steel slab urinal ? x ?mm high, including breaking up and removing ?mm wide concrete urinal step

No

Not Priced

2959

2968

2969

Taking out/off and removing glass and mirrors

2970

Glass from timber windows with beads, including cleaning out rebates and preparing for new glass



Not Priced

Glass from aluminium windows with beads, including cleaning out rebates and preparing for new glass



Not Priced

Glass from steel windows, including cleaning out rebates and preparing for new glass



Not Priced

2973

Mirror ? x ?mm high from wall

No

Not Priced

2974

Mirror ? x ?mm high from wall, including making good white glazed tiling

No

Not Priced

2971

2972

2975

CUTTING THROUGH FLOORS AND CEILINGS

Carried forward Bill No 2 Alterations ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-32-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2976

Cutting through

2977

?mm Thick unreinforced concrete surface bed for ?mm wide concrete wall footings and making good concrete on both sides of new ? brick walls

m

Not Priced

?mm Thick unreinforced concrete surface beds for ?mm diameter pipes and making good concrete

m

Not Priced

Gypsum platerboard ceilings and timber brandering for ? brick walls, including making good on both sides of walls (new cornices elsewhere)

m

Not Priced

2978

2979

2980

BUILDING UP OPENINGS

2981

Brickwork in NFP bricks in class II mortar in building up openings

2982

Half brick walls



Not Priced

2983

One brick walls



Not Priced

2984

?mm Hollow walls of two half brick skins



Not Priced

2985

Brickwork in NFP bricks in class II mortar in building up openings, including bonding new to existing and making good cement plaster on one (both?) side(s) (making good paintwork elsewhere)

2986

Opening ? x ?m high overall in ? brick wall

No

Not Priced

2987

Sundries

2988

Cutting toothings and bonding new brickwork to existing



Not Priced

2989

"?" face bricks pointed with flush (recessed?) horizontal and vertical joints

2990

Extra over brickwork for face brickwork in patches



Not Priced

2991

Cutting toothings and bonding new face brickwork to existing

m

Not Priced

?mm Wide brick-on-edge header course sills set sloping and slightly projecting

m

Not Priced

2992

Carried forward Bill No 2 Alterations ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-33-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2993

PREPARATORY WORK TO EXISTING SURFACES

2994

Hacking faces of existing concrete columns, beams, etc to receive plaster



Not Priced

2995

Hacking faces of existing face brickwork to receive plaster



Not Priced

2996

Making good defects in existing screeded floors with "?"



Not Priced

2997

MAKING GOOD OF FINISHES, ETC

2998

Making good face brickwork

2999

Ends of half brick (one brick?) walls

m

Not Priced

3000

Faces of walls where half brick (one brick?) cross walls removed

m

Not Priced



Not Priced

m

Not Priced



Not Priced

3001

Making good gypsum plasterboard ceilings and timber brandering

3002

Ceilings in patches

3003

Ceilings where half brick (one brick?) walls removed

3004

Making good 300 x 300 x 2,5mm semi-flexible vinyl floor tiles

3005

Floors in patches

3006

Floors where ?mm partitions removed

m

Not Priced

3007

Floors where half brick (one brick?) walls removed

m

Not Priced

3008

Making good untinted granolithic

3009

Making good cement screeds

3010

25mm Thick on floors in patches



Not Priced

3011

Floors where half brick (one brick?) walls removed

m

Not Priced

3012

Making good internal cement plaster

3013

Walls in patches



Not Priced

3014

Concrete ceilings in patches



Not Priced

3015

Walls where half brick (one brick?) walls removed



Not Priced

Carried forward Bill No 2 Alterations ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-34-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 3016

Concrete ceilings where half brick (one brick?) walls removed

3017

Making good ? x ? x ?mm white glazed ceramic tiles

3018

Walls in patches

3019

Walls where half brick (one brick?) walls removed

3020

OPENINGS THROUGH EXISTING WALLS ETC

3021

Altering openings

3022

Altering opening in one brick wall where ? x ?m high steel window removed to form opening for new double door and frame ? x ?m high overall by breaking out brickwork on both sides and bottom, including making good cement plaster on one side and into reveals and face brickwork on other side and into reveals and with 20 MPa concrete threshold with steel trowelled finish (new door and frame and making good paintwork elsewhere)

R

Not Priced

m

Not Priced



Not Priced

m

Not Priced

No

Not Priced

No

Not Priced

3023

Breaking out for and forming plain openings through brick walls, including prestressed concrete lintels, making good cement plaster on both sides and into reveals and with 20 MPa concrete thresholds with steel trowelled finish (making good paintwork elsewhere)

3024

Opening ? x ?mm high through half brick (one brick?) wall

3025

Breaking out for and forming openings through brick walls for new doors and frames, including prestressed concrete lintels, making good cement plaster on both sides and into reveals and with 20 MPa concrete thresholds with steel trowelled finish (new doors and frames and making good paintwork elsewhere)

3026

Breaking out for and forming openings through brick walls for new doors and frames, including brick lintels, making good cement plaster on one side and into reveals and face brickwork on other side and into reveals and with 20 MPa concrete thresholds with steel trowelled finish (new doors and frames and making good paintwork elsewhere)

3027

Opening for door with timber frame ? x ?m high overall through half brick (one brick?) wall

No

Not Priced

Opening for door with steel frame ? x ?m high overall through half brick (one brick?) wall

No

Not Priced

3028

Carried forward Bill No 2 Alterations ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-35-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

3029

Breaking out for and forming openings through brick walls for new windows, including prestressed concrete lintels, making good cement plaster on both sides and into reveals and with sloping fibre-cement sills on outside and flat fibre-cement sills on inside (new windows and making good paintwork elsewhere)

3030

Breaking out for and forming openings through brick walls for new windows, including brick lintels, making good cement plaster on one side and into reveals and face brickwork on other side and into reveals and with sloping quarry tile sills on outside and flat quarry tile sills on inside (new windows and making good paintwork elsewhere)

3031

Opening for window ? x ?m high through one brick wall

No

Not Priced

3032

Opening for window ? x ?m high through ?mm hollow wall of two half brick skins, including building cavity solid

No

Not Priced

Carried to summary Bill No 2 Alterations ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-36-

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

33

BILL NO ?

34

EARTHWORKS (PROVISIONAL)

35

SUPPLEMENTARY PREAMBLES

36

User Note

37

The following are typical examples of descriptions of "nature of ground"

38

Nature of ground

39

The nature of the ground is assumed to be loose sandy material, therefore "earth", but possibly interspersed with "soft rock" or "hard rock"

40

The nature of the ground is assumed to be gravel, therefore "earth", but possibly interspersed with "soft rock" or "hard rock"

41

The nature of the ground is assumed to be silty clay with loose river boulders varying in size up to approximately 450mm diameter, all of which will be deemed as "earth", but possibly interspersed with "hard rock"

42

Trial holes indicate that the nature of the ground is silty clay to a depth of approximately 500mm with fine to medium loose sandy material below, therefore "earth"

43

A soils investigation has been carried out on the site by the engineer and the report is annexed to these bills of quantities. The soils report indicates that the ground varies between silty sand, reworked soil of mixed origin and residual shale, all of which will be deemed as "earth". All very hard unweathered shale, ironstone, etc, the removal of which necessitates the use of explosives or heavy duty hydraulic percussion hammers (peckers), will be classified as "hard rock"

44

User note

45

The following are typical examples of descriptions of "subterranean water"

Carried forward Bill No 3 Earthworks ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-37-

Quantity

Rate

Amount

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 46

Subterranean water

47

No subterranean water is expected

R

Not Priced

The water table is expected to vary between approximately ?m and ?m below natural ground level. The removal of subterranean water is given separately 48

Excavation for working space in rock

49

Notwithstanding clause 11 page 8 of the Standard System of Measuring Building Work, excavation for working space in rock will be measured in cubic metres to the extent executed and given as "extra over" bulk excavation or trench and hole excavation as the case may be

50

Carting away of excavated material

51

Descriptions of carting away of excavated material shall be deemed to include loading excavated material onto trucks directly from the excavations or, alternatively, from stock piles situated on the building site

52

Filling

53

Notwithstanding the reference to prescribed multiple handling in clause 1 page 6 of the Standard System of Measuring Building Work, prices for filling and backfilling shall include for all selection and any necessary multiple handling of material

54

User note

55

When no information regarding density tests is available the following preamble in respect of testing may be inserted

56

Testing

57

Prices for filling are to include for all necessary density tests in accordance with SABS 1200D

58

DEMOLITIONS ETC

59

Breaking up and removing

60

?mm Thick unreinforced concrete surface beds, paving, etc



Not Priced

61

?mm Thick mesh reinforced concrete surface beds, paving, etc



Not Priced

Carried forward Bill No 3 Earthworks ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-38-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

62

?mm Thick concrete block paving on sand bed



Not Priced

63

?mm Thick brick paving with mortar joints on sand bed



Not Priced

64

? x ?mm Unreinforced concrete kerbs

m

Not Priced

65

? x ?mm Brick kerbs with mortar joints and concrete bedding

m

Not Priced

66

Taking down and removing

67

Steel diamond mesh fence ?m high with steel posts and droppers

m

Not Priced

68

? Fence ?m high with ? posts and ? droppers

m

Not Priced

69

Steel diamond mesh security fence with steel posts and droppers and 45 degree barbed wire overhang, ?m high overall

m

Not Priced

70

Demolishing and removing

71

Half brick boundary or yard walls ?m high

m

Not Priced

72

Half brick boundary or yard walls ?m high with pilasters at ?m centres

m

Not Priced

73

One brick boundary or yard walls ?m high

m

Not Priced

74

Single storey building with pitched roof, ? x ?m on plan and ?m high at eaves, comprising unreinforced concrete surface bed, ? external walls, ? internal walls and ? roof covering on ? trusses

No

Not Priced

? storey building with flat roof, ? x ?m on plan and ?m high overall, comprising unreinforced concrete surface bed, reinforced concrete intermediate and roof slabs, ? external walls and ? internal walls

No

Not Priced

75

76

SITE CLEARANCE ETC

77

User Note

78

Where the value is of significance, the removal of hedges etc shall be given separately in meters or in number

Carried forward Bill No 3 Earthworks ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-39-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

79

Site clearance

80

Digging up and removing rubbish, debris, vegetation, hedges, shrubs, bush, etc and trees not exceeding 200mm girth



Not Priced

Stripping average ?mm thick layer of top soil and depositing material in prescribed stock piles on site



Not Priced

81

82

REMOVAL OF TREES ETC

83

Taking out and removing, grubbing up roots and filling in holes

84

Tree stump exceeding 200mm and not exceeding 500mm girth

No

Not Priced

85

Tree stump exceeding ?mm and not exceeding ?mm girth

No

Not Priced

86

Cutting down and removing, grubbing up roots and filling in holes

87

Hedge not exceeding ?mm high

m

Not Priced

88

Hedge exceeding ?mm and not exceeding ?mm high

m

Not Priced

89

Tree exceeding 200mm and not exceeding 500mm girth

No

Not Priced

90

Tree exceeding ?mm and not exceeding ?mm girth

No

Not Priced

91

BULK EXCAVATION, FILLING, ETC

92

User Note

93

This section is given as an alternative option and in the event of it being utilised, the excavation, filling, etc other than bulk is to be given in the later section under the appropriate heading



Not Priced

If this alternative is not utilised then all excavations etc (bulk and otherwise) is to be given in the later section under the appropriated heading 94

EXCAVATIONS ETC

95

Open face excavation in earth over sloping site

96

Open face excavation

Carried forward Bill No 3 Earthworks ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-40-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

97

Excavation in earth for basement

98

Not exceeding 2m deep



Not Priced

99

Exceeding 2m and not exceeding 4m deep



Not Priced

100

Exceeding 4m and not exceeding 6m deep



Not Priced

101

Exceeding ?m and not exceeding ?m deep



Not Priced

102

Excavation in earth within basement (basement level exceeding ?m and not exceeding ?m deep below ground level)

103

Not exceeding 2m deep to reduce levels to final levels under floors etc



Not Priced

104

To remove sloping banks



Not Priced

105

To remove sloping banks in ?m alternating sections



Not Priced

106

Back excavation of vertical sides of excavations in earth for working space including backfilling compacted to ?% Mod AASHTO density

107

Not exceeding 500mm deep for placing and removing formwork to walls etc, ?mm away from excavated face



Not Priced

Exceeding ?m and not exceeding ?m deep for placing and removing formwork to walls etc, ?mm away from excavated face



Not Priced

Not exceeding 500mm deep for placing and removing formwork to walls etc, against excavated face



Not Priced

Exceeding ?m and not exceeding ?m deep for placing and removing formwork to walls etc, against excavated face



Not Priced

Not exceeding 500mm deep for placing and removing formwork to walls etc and building brick lining, ?mm away from excavated face



Not Priced

Exceeding ?m and not exceeding ?m deep for placing and removing formwork to walls etc and building brick lining, ?mm away from excavated face



Not Priced



Not Priced

108

109

110

111

112

113

Extra over bulk excavations in earth for excavation in

114

Soft rock

Carried forward Bill No 3 Earthworks ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-41-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 115

Hard rock

116

Extra over bulk excavations in earth for breaking up and removing

117

R

Not Priced



Not Priced

Brickwork



Not Priced

118

Unreinforced concrete



Not Priced

119

Reinforced concrete



Not Priced

120

Extra over all excavations for carting away

121

Surplus material from excavations and/or stock piles on site to a dumping site to be located by the contractor



Not Priced

Surplus material from excavations and/or stock piles on site to a dumping site situated approximately ?km from the building site



Not Priced

122

123

Risk of collapse of excavations

124

Sides of bulk excavations not exceeding 1,5m deep



Not Priced

125

Sides of bulk excavations exceeding 1,5m deep



Not Priced

126

Keeping excavations free of water

127

Keeping excavations free of water other than subterranean water

128

De-watering of seepage water and water from other sub-soil sources

129

Provide pump with minimum ? litre/hour capacity at ?m head, including maintenance and removal

130

Provide necessary hoses for the above including couplings etc

131

Allow for pumping (one pump)

132

FILLING ETC

133

Earth filling obtained from the excavations (not compacted)

Carried forward Bill No 3 Earthworks ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-42-

Item

Not Priced

No

Not Priced

m

Not Priced

Hrs

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

134

Earth filling obtained from the excavations including haulage approximately ?m from perimeter of excavations (not compacted)

135

In prescribed stock piles on site



Not Priced

136

Over site to make up levels



Not Priced

137

In landscape mounds, berms, etc



Not Priced

138

Earth filling obtained from the excavations and/or prescribed stock piles on site (not compacted)

139

Earth filling obtained from the excavations and/or prescribed stock piles on site, compacted to ?% Mod AASHTO density

140

Earth filling obtained from the excavations and/or prescribed stock piles on site including haulage approximately ?m from perimeter of excavations or stock piles, compacted to ?% Mod AASHTO density

141

Earth filling supplied by the contractor, compacted to ?% Mod AASHTO density

142

Over site



Not Priced

143

Over site to form platforms



Not Priced

144

Compaction of surfaces

145

Compaction of ground surface over site by wetting and compacting with ? passes of a ? ton vibratory roller



Not Priced

Compaction of ground surface under floors etc including scarifying for a depth of 150mm, breaking down oversize material, adding suitable material where necessary and compacting to ?% Mod AASHTO density



Not Priced

146

147

Prescribed density tests on filling

148

"Modified AASHTO Density" test

No

Not Priced

149

"Natural California Bearing Ratio" test

No

Not Priced

150

"Road Indicator" test

No

Not Priced

151

"Field Density" test including "Optimum Moisture Content" (four readings per test)

No

Not Priced

Carried forward Bill No 3 Earthworks ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-43-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 152

EXCAVATION, FILLING, ETC

153

EXCAVATION, FILLING, ETC OTHER THAN BULK

154

User note

155

Only the appropriate one of the above two alternative headings is to be inserted, depending on whether the separate "bulk excavation, filling, etc" option is utilised or not

156

EXCAVATIONS, ETC

157

Open face excavation in earth over sloping site

158

Open face excavation

159

Excavation in earth not exceeding 2m deep

160

Excavation in earth exceeding 2m and not exceeding 4m deep

161

Excavation in earth exceeding ?m and not exceeding ?m deep

162

R

Not Priced



Not Priced

Basements



Not Priced

163

Lift pits



Not Priced

164

Swimming pools



Not Priced

165

Reduced levels under floors



Not Priced

166

Trenches



Not Priced

167

Holes



Not Priced

168

Trenches including working around piles



Not Priced

169

Holes including working around piles



Not Priced

170

Thickening under surface beds etc



Not Priced

171

Underpinning in ?m alternating sections under existing foundations



Not Priced

172

Excavation in earth not exceeding 2m deep below reduced level (reduced level exceeding ?m and not exceeding ?m below ground level)

Carried forward Bill No 3 Earthworks ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-44-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

173

Excavation in earth exceeding ?m and not exceeding ?m deep below reduced level (reduced level exceeding ?m and not exceeding ?m below ground level)

174

Excavation in earth not exceeding 2m deep within basement (basement level exceeding ?m and not exceeding ?m deep below ground level)

175

Excavation in earth exceeding ?m and not exceeding ?m deep within basement (basement level exceeding ?m and not exceeding ?m deep below ground level)

176

To reduce levels to final levels under floors etc



Not Priced

177

To remove sloping banks



Not Priced

178

To remove sloping banks in ?m alternating sections



Not Priced

179

Lift pits



Not Priced

180

Trenches



Not Priced

181

Holes



Not Priced

182

Trenches including working around piles



Not Priced

183

Holes including working around piles



Not Priced

184

Thickening under surface beds etc



Not Priced

185

Underpinning in ?m alternating sections under existing foundations



Not Priced

186

Back excavation of vertical sides of excavations in earth for working space including backfilling compacted to ?% Mod AASHTO density

187

Not exceeding 500mm deep for placing and removing formwork to walls etc, ?mm away from excavated face



Not Priced

Exceeding ?m and not exceeding ?m deep for placing and removing formwork to walls etc, ?mm away from excavated face



Not Priced

Not exceeding 500mm deep for placing and removing formwork to walls etc, against excavated face



Not Priced

Exceeding ?m and not exceeding ?m deep for placing and removing formwork to walls etc, against excavated face



Not Priced

188

189

190

Carried forward Bill No 3 Earthworks ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-45-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 191

192

R

Not Priced

Not exceeding 500m deep for placing and removing formwork to walls etc and building brick lining, ?mm away from excavated face



Not Priced

Exceeding ?m and not exceeding ?m deep for placing and removing formwork to walls etc and building brick lining, ?mm away from excavated face



Not Priced

193

Extra over bulk excavations in earth for excavation in

194

Soft rock



Not Priced

195

Hard rock



Not Priced

196

Extra over bulk excavations in earth for breaking up and removing

197

Brickwork



Not Priced

198

Unreinforced concrete



Not Priced

199

Reinforced concrete



Not Priced

200

Extra over trench and hole excavations in earth for excavation in

201

Soft rock



Not Priced

202

Hard rock



Not Priced

203

Extra over trench and hole excavations in earth for breaking up and removing

204

Brickwork



Not Priced

205

Unreinforced concrete



Not Priced

206

Reinforced concrete



Not Priced

207

Extra over all excavations for carting away

208

Surplus material from excavations and/or stock piles on site, to a dumping site to be located by the contractor



Not Priced

Surplus material from excavations and/or stock piles on site, to a dumping site situated approximately ?km from the building site



Not Priced

209

Carried forward Bill No 3 Earthworks ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-46-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

210

Risk of collapse of excavations

211

Sides of bulk excavations not exceeding 1,5m deep



Not Priced

212

Sides of bulk excavations exceeding 1,5m deep



Not Priced

213

Sides of trench and hole excavations not exceeding 1,5m deep



Not Priced

214

Sides of trench and hole excavations exceeding 1,5m deep



Not Priced

215

Keeping excavations free of water

216

Keeping excavations free of all water other than subterranean water

Item

217

De-watering of seepage water and water from other sub-soil sources

218

Provide pump with minimum ? litre/hour capacity at ?m head, including maintenance and removal

219

Provide necessary hoses for the above including couplings etc

Not Priced

No

Not Priced

m

Not Priced

Hrs

Not Priced

220

Allow for pumping (one pump)

221

FILLING ETC

222

Earth filling obtained from the excavations (not compacted)

223

Earth filling obtained from the excavations including haulage approximately ?m from perimeter of excavations (not compacted)

224

In prescribed stock piles on site



Not Priced

225

Over site to make up levels



Not Priced

226

In landscape mounds, berms, etc



Not Priced

227

Earth filling obtained from the excavations and/or prescribed stock piles on site (not compacted)

228

Earth filling obtained from the excavations and/or prescribed stock piles on site including haulage approximately ?m from perimeter of excavations or stock piles (not compacted)

229

Earth filling supplied by the contractor (not compacted)

Carried forward Bill No 3 Earthworks ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-47-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

230

Earth filling obtained from the excavations and/or prescribed stock piles on site, compacted to ?% Mod AASHTO density

231

Earth filling obtained from the excavations and/or prescribed stock piles on site including haulage approximately ?m from perimeter of excavations or stock piles, compacted to ?% Mod AASHTO density

232

Earth filling supplied by the contractor, compacted to ?% Mod AASHTO density

233

Earth filling obtained from the excavations and/or prescribed stock piles on site stabilised with ?% cement (lime ?) per volume, compacted to ?% Mod AASHTO density

234

Over site to make up levels



Not Priced

235

In landscape mounds, berms, etc



Not Priced

236

Under floors, steps, pavings, etc



Not Priced

237

Backfilling behind retaining walls



Not Priced

238

Backfilling to trenches, holes, etc



Not Priced

239

Garden soil filling obtained from the excavations and/or prescribed stock piles on site

240

Garden soil filling obtained from the excavations and/or prescribed stock piles on site including haulage approximately ?m from perimeter of excavations or stock piles

241

Garden soil filling supplied by the contractor

242

Garden soil filling supplied by the contractor (3 parts top soil, 1 part compost and 1 part milled pine bark)

243

Over site



Not Priced

244

In landscape mounds, berms, etc



Not Priced

245

In plant boxes



Not Priced

246

Coarse river sand filling supplied by the contractor

247

Under floors etc



Not Priced

248

Behind retaining walls



Not Priced

Carried forward Bill No 3 Earthworks ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-48-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 249

In floor ducts

250

Hardcore filling

251

Under floors etc

252

Stone filling of ?mm broken stone

253

R

Not Priced



Not Priced



Not Priced

Under floors etc



Not Priced

254

Behind retaining walls



Not Priced

255

In flower boxes



Not Priced

256

In sub-soil drain trenches around pipes



Not Priced

257

Compaction of surfaces

258

Compaction of ground surface under floors etc by wetting and compacting with ? passes of a ? ton vibratory roller



Not Priced

Compaction of ground surface under floors etc including scarifying for a depth of 150mm, breaking down oversize material, adding suitable material where necessary and compacting to ?% Mod AASHTO density



Not Priced

259

260

Prescribed density tests on filling

261

"Modified AASHTO Density" test

No

Not Priced

262

"Natural California Bearing Ratio" test

No

Not Priced

263

"Road Indicator" test

No

Not Priced

264

"Field Density" test including "Optimum Moisture Content" (four readings per test)

No

Not Priced

265

STONE PITCHING

266

Stone pitching of approximately ?mm diameter river stones tightly packed including preparation of ground surface under

267

?mm Thick against sloping banks



Not Priced

268

?mm Thick against sloping banks bedded and jointed in 1:8 cement mortar and pointed with hollow recessed joints



Not Priced

269

GRASSING

Carried forward Bill No 3 Earthworks ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-49-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

270

User note

271

A suitable specification in respect of ground preparation, planting, fertilising and maintenance is to be obtained from the principal agent and inserted

272

Grassing of roots in rows

273

Grassing of rolls approximately ?mm thick

274

Grassing of sods approximately ? x ? x ?mm thick

275

"Kikuyu" grass over site



Not Priced

276

"?" grass over site



Not Priced

277

"?" grass on sports fields



Not Priced

278

Fertilising

279

Fertilising garden soil with "?" fertiliser spread at a rate of ? g/m² and "?" fertiliser spread at a rate of ? g/m² including working evenly into top ?mm depth of soil



Not Priced

Fertilising grassed areas with "?" fertiliser at a rate of ? g/m² after completion of planting



Not Priced

280

281

Maintenance

282

Maintenance of grassed areas for a period of ? months (total area approximately ?m²) including regularly cutting, weeding and irrigating as necessary

Item

Not Priced

GABIONS AND INTERLOCKING BLOCK RETAINING STRUCTURES 284

User Note

285

Gabion boxes and mattresses are available in a wide range of qualities, types and sizes. It is advisable to obtain the specification from the engineer. The following is a typical specification:

286

Gabions

287

Gabions are to be of double twisted hexagonal wire mesh (nominal 80 x 100mm mesh of 2,7mm galvanised wire, with 3,5mm galvanised wire framing and with partitions at 1m centres). All wire to be hot-dip galvanised to SANS 675

Carried forward Bill No 3 Earthworks ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-50-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

288

Gabions of galvanised wire boxes laced together and filled with broken stone

289

500mm Thick retaining wall of 3 x 2 x 0,5m boxes properly bonded



Not Priced

300mm Thick embankment protection of 3 x 3 x 0,3m mattresses with diaphragm divisions at 1m centres, butt jointed



Not Priced



Not Priced

Under stone filled gabion mattresses including preparing ground surface under



Not Priced

302

Vertically behind stone filled gabion retaining walls



Not Priced

303

Over stone percolation beds in flower boxes



Not Priced

304

Around stone filling in sub-soil drain trenches



Not Priced

290

291

Interlocking planter blocks

292

User Note

293

Planter blocks are available in various sizes and in "standard" and "heavy duty" in each size. Type is dependent mainly on wall and soil conditions

294

"?" precast concrete interlocking planter blocks finished smooth on exposed surfaces

295

Retaining structure with stepped face and curves as required to suit slopes, of ? x ? x ?mm high type ? interlocking planter blocks laid with horizontal bed joints to ? degree slope, including average ?mm thick compacted earth filling behind blocks and filling blocks with garden soil lightly tamped as the work proceeds

296

FILTER FABRIC

297

User Note

298

Filter fabrics are available in a wide range of qualities and types. It is advisable to obtain the specification from the engineer

299

Type ? filter fabric blanket with ?mm laps Non-woven continuous filament needle punch polyester filter fabric blanket weighing ? kg/m², with ?mm laps

301

Carried forward Bill No 3 Earthworks ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-51-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 305

R

Not Priced

SOIL POISONING Weedkiller (active ingredients metalaclor 102,8 g/l, terbitilasien 248,6 g/l and atrasien 248,6 g/l) mixed in the proportion of 100 ml weedkiller to 100 l water and applied at a rate of 10 l/m²

307

Under paving etc

308

Soil insecticide in accordance with SANS 5859

309

310



Not Priced

Under floors etc including forming and poisoning shallow furrows against foundation walls etc, filling in furrows and ramming



Not Priced

To bottoms and sides of trenches etc



Not Priced

Carried to summary Bill No 3 Earthworks ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-52-

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

6057

BILL NO ?

6058

LATERAL SUPPORT

6059

User note

6060

No provision has been made in the "Model Preambles" for lateral support. Users are therefore advised to include the engineer's comprehensive lateral support project specification in these bills of quantities and to insert relevant supplementary preambles where necessary

Quantity

Rate

Amount

Supplementary preambles hereafter are given as examples only, reproduced from typical bills of quantities where some of the preambles may have been specifically required The range of items provided in this bill is an example of typical items with (or without) trade names to show possible ways of describing such items. Users must take special care that only items relevant to the specific project are to be included and that descriptions should be adapted as necessary to suit the particular circumstances Headings and descriptions of items in this bill assume that the specification and/or supplementary preambles fully describe materials to be used, methods of fixing, etc 6061

SUPPLEMENTARY PREAMBLES

6062

GROUND ANCHORS AND ROCK ANCHORS

6063

User note

6064

The nature of the work and the excavated faces to be supported, any limitations affecting the ground anchoring, the strata through which the anchors will have to pass and the position of any cables, pipes or other services, if not already included in the engineer's specification, must be annexed to the bills of quantities or included in this bill It is recommended that the preambles to ground anchors should clarify the distinction between "rock anchors" and "soft ground anchors". A typical preamble could read as follows:

6065

Where lower anchorages occur in material requiring underreaming and/or secondary or subsequent injections they are classified as soft ground anchors. All other lower anchorages shall be classified as rock anchors

Carried forward Bill No 4 Lateral Support ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-53-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

6066

DRILLING FOR SOLDIERS

6067

Cassification of material

6068

"Hard rock" shall mean granite, quartzitic sandstone or other rock of similar hardness, the removal of which would normally require drilling, wedging and splitting or the use of explosives

6069

"Earth" shall mean all ground other than that classified as "hard rock" and shall include made-up ground and any loose stones or pieces of concrete not exceeding 0,03m3 in volume and hard material the removal of which would normally require the use of pneumatic tools and includes hard shale, ferricite, compact ouklip and material of similar hardness

6070

INSURANCE

6071

Provide the sum of R ? (? Rand) for premiums for an insurance policy against claims arising from the removal of lateral support

Item

Not Priced

6072

Profit

Item

Not Priced

6073

User note

6074

The following item is an alternative to a provisional sum

6075

Insurance policy against claims arising from the removal of lateral support up to a limit of R ? (? Rand) per claim with no limit on the number of claims that may occur

Item

Not Priced

Item

Not Priced

6076

MOVEMENT MONITORING

6077

Establishing bench marks, pegs, painted lines and arrows, etc as required for movement monitoring control including necessary excavation, steel pegs, concrete bedding, paint, etc and protection and maintenance thereof during the works

6078

User note

6079

The following item is given only when a part survey check is required and the description should be adapted as necessary to suit the particular circumstances

Carried forward Bill No 4 Lateral Support ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-54-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 6080

6081

R

Not Priced

Periodic movement survey check comprising necessary surveying equipment including setting up thereof, accurately monitoring ? control points and providing records of the results of the survey

No

Not Priced

Periodic movement survey check comprising necessary surveying equipment including setting up thereof, accurately monitoring control points and providing records of the results of the survey

No

Not Priced

6082

TEMPORARY GROUND ANCHORS

6083

PERMANENT GROUND ANCHORS

6084

ROCK BOLTS ETC

6085

Establishment

6086

Transporting and establishment on site of necessary plant for the execution of the work and removal thereof on completion

6087

User note

6088

The following item is an alternative when piling forms part of the lateral support

6089

Transporting and establishment on site of necessary plant for the execution of the work including plant required for the augering of soldiers and removal thereof on completion

Item

Not Priced

Item

Not Priced

6090

Test anchors

6091

?kN Test anchor including rock anchor lower anchorage, free length of cable ?m long, upper anchorage with ? x ? x ?mm long sawn softwood thrust block, necessary testing, destressing and removal of thrustblock and exposed cable end

No

Not Priced

?kN Test anchor including soft ground anchor lower anchorage, free length of cable ?m long, upper anchorage with ? x ? x ?mm long sawn softwood thrust block, necessary testing, destressing and removal of thrustblock and exposed cable end

No

Not Priced

No

Not Priced

6092

6093

Ground anchors of ?kN working load

6094

Lower anchorage rock anchor

Carried forward Bill No 4 Lateral Support ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-55-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

6095

Lower anchorage soft ground anchor

No

Not Priced

6096

Upper anchorage including thrust plate

No

Not Priced

6097

Upper anchorage including thrust plate with head and upper part of tendon painted

No

Not Priced

Upper anchorage including thrust plate with head and upper part of tendon powder coated

No

Not Priced

Upper anchorage including thrust plate with head covered and cap filled with grease

No

Not Priced

Upper anchorage including thrust plate with head concreted or grouted into box-out, including necessary formwork etc

No

Not Priced

6098

6099

6100

6101

Free length of cable

m

Not Priced

6102

Free length of cable including grease and sheath

m

Not Priced

6103

Waterproofing of ground anchors

6104

Initial test with water of cable hole for fissures and voids

No

Not Priced

6105

Re-testing with water of cable hole for fissures and voids

No

Not Priced

6106

Cement grouting of cable holes to prevent ingress of water

kg

Not Priced

6107

Re-drilling holes or washing out of cement grout

m

Not Priced

6108

Encasing of cables in cement grout

m

Not Priced

6109

Rock bolts

6110

Soil nails

6111

Rock dowels

6112

?mm Diameter x ?mm long rock dowel in cement grout

No

Not Priced

6113

?mm Diameter x ?mm long rock bolt in cement grout including thrust plate, washers and nut

No

Not Priced

?mm Diameter x ?mm long soil nail in cement grout including thrust plate, washers and nut

No

Not Priced

?mm Diameter x ?mm long expanding rock bolt including mechanical anchorage mechanism, thrust plate, washers and nut

No

Not Priced

6114

6115

Carried forward Bill No 4 Lateral Support ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-56-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 6116

?mm Diameter x ?mm long expanding rock bolt in cement grout, including mechanical anchorage mechanism, thrust plate, washers and nut

R

Not Priced

No

Not Priced

No

Not Priced

m

Not Priced



Not Priced

m

Not Priced

6117

SOLDIERS, BOARDING, SHOTCRETING, ETC

6118

Setting up plant at soldier position

6119

Drilling not exceeding 10m deep in earth below ground level for soldiers

6120

Drilling exceeding ?m and not exceeding ?m deep in earth below ground level for soldiers

6121

?mm Diameter shafts

6122

Drilling in strata of a more difficult character

6123

Extra over drilling in earth for drilling in hard rock

6124

?MPa/?mm unreinforced concrete

6125

?mm Diameter shafts as casing to soldiers

6126

Steel soldiers

6127

Composite whalers ?mm long consisting of two ? x ?mm x ?kg/m rolled steel I-section beams spaced ?mm apart and secured together at maximum ?mm centres and at ends with ? x ? x ?mm thick steel plates on both sides including cutting, butt jointing, welding, etc

t

Not Priced

Composite soldiers ?mm long consisting of two ? x ?mm x ?kg/m rolled steel I-section beams spaced ?mm apart and secured together at maximum ?mm centres and at ends with ? x ? x ?mm thick steel plates on both sides including cutting, butt jointing, welding, etc

t

Not Priced

m

Not Priced

6128

6129

?:? Cement/sand mortar packing

6130

?mm Minimum thickness x ?mm wide packing between soldiers and face of excavation

6131

?Mpa/?mm unreinforced shotcrete lining

6132

?mm Thick to face of excavation



Not Priced

6133

?mm Thick to face of excavation between soldiers



Not Priced

Carried forward Bill No 4 Lateral Support ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-57-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 6134

R

Not Priced

?mm Thick to face of excavation circular on plan between soldiers



Not Priced

?mm Thick to face of excavation between soldiers including type ? fabric reinforcement (welded to steel soldiers?)



Not Priced

?mm Thick to face of excavation circular on plan between soldiers including type ? fabric reinforcement (welded to steel soldiers?)



Not Priced

?mm Thick to face of excavation including type ? fabric reinforcement fixed to projecting rock bolts (soil nails?)



Not Priced

6138

?mm Diameter weep hole drilled through shotcrete lining

No

Not Priced

6139

?mm Diameter weep hole drilled through reinforced shotcrete lining

No

Not Priced

?mm Diameter weep pipe through ?mm thick shotcrete lining including ? x ?mm "?" percolation pad

No

Not Priced

6135

6136

6137

6140

6141

Fabric reinforcement

6142

Type ? fabric reinforcement in shotcrete lining (welded to steel soldiers?)



Not Priced

Type ? fabric reinforcement in shotcrete lining circular on plan (welded to steel soldiers?)



Not Priced

Type ? fabric reinforcement in shotcrete lining fixed to projecting rock bolts (soil nails?)



Not Priced

6143

6144

6145

Close boarding

6146

?mm Thick sawn softwood close boarding between steel soldiers including hand packing soil behind



Not Priced

Wedging ?mm thick boarding into web of ? x ?mm x kg/m steel soldier with timber wedges

m

Not Priced

6147

6148

TESTING AND RE-TENSIONING OF GROUND ANCHORS SUBSEQUENT TO INITIAL ACCEPTABILITY TESTING AND DESTRESSING

6149

Transporting and re-establishment on site of necessary plant for testing, re-tensioning and de-stressing of ground anchors

6150

Testing of ground anchor

Item

Not Priced

No

Carried forward Bill No 4 Lateral Support ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-58-

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

6151

Re-tensioning of ground anchor

No

Not Priced

6152

Destressing of ground anchor

No

Not Priced

Carried to summary Bill No 4 Lateral Support ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-59-

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

6153

BILL NO ?

6154

PILING

6155

User note

6156

No provision has been made in the "Model Preambles" for piling. Users are therefore advised to include the engineer's comprehensive piling project specification in the bills of quantities and to insert relevant supplementary preambles where necessary

Quantity

Rate

Amount

Supplementary preambles hereafter are given as examples only, reproduced from typical bills of quantities where some of the preambles may have been specifically required The range of items provided in this bill is an example of typical items with (or without) trade names to show possible ways of describing such items. Users must take special care that only items relevant to the specific project are to be included and that descriptions should be adapted as necessary to suit the particular circumstances Headings and descriptions of items in this bill assume that the specification and/or supplementary preambles fully describe materials to be used, methods of fixing, etc 6157

SUPPLEMENTARY PREAMBLES

6158

Indemnity

6159

The contractor shall take full responsibility for piling work and shall guarantee that piling work will support the calculated loads laid down by the engineer without injurious settlement. The actual lengths of piles shall be determined on site by the contractor in consultation with the engineer who will give all assistance possible. This does not in any way relieve the contractor of his responsibility or obligation to provide the specified guarantee The contractor shall indemnify the employer against any injury to or death of any person and all loss or damage to all structures resulting from the failure of any pile. In the event of the failure of a pile the contractor shall make good such pile and all consequent damage at his own expense The contractor shall insure by means of a policy, approved by the principal agent, against risks arising out of the responsibilities, guarantee and indemnities specified. The contractor shall pay all premiums in respect of this insurance policy. The guarantee shall be for the amount and effective period as stated hereafter in this bill Carried forward Bill No 5 Piling ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-60-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 6160

Scope of work

6161

?The work comprises the installation of ? piles. The contractor is referred to drawing No ? issued together with these bills of quantities in order to acquaint himself fully with the nature and scope of the work?

R

Not Priced

?The work comprises the design and installation of ? piles. The contractor is referred to drawing No ? issued together with these bills of quantities in order to aquaint himself fully with the nature and scope of the work? ?Piles are to be installed subsequent to the site being excavated or filled to the correct levels? ?The building platform is already excavated, filled, levelled and compacted to the required levels? 6162

Drilling

6163

Cassification of material

6164

"Hard rock" shall mean granite, quartzitic sandstone or other rock of similar hardness, the removal of which would normally require drilling, wedging and splitting or the use of explosives "Earth" shall mean all ground other than that classified as "hard rock" and shall include made-up ground and loose stones or pieces of concrete not exceeding 0,03m3 in volume as well as hard material the removal of which would normally warrant the use of pneumatic tools and which includes hard shale, ferricite, compact ouklip and material of similar hardness

6165

GUARANTEE AND INSURANCE

6166

Insurance policy against claims arising from the installation of piling up to a limit of R ? (? Rand) per claim with no limit on the number of claims that may occur and effective for a period of ? years from the date of completion of the contract

6167

ESTABLISHMENT

6168

Transporting to and establishment on site of necessary plant for the execution of the work and removal thereof on completion

6169

Setting up plant at pile position

Item

Not Priced

Item

Not Priced

No

Carried forward Bill No 5 Piling ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-61-

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

6170

PRECAST CONCRETE DRIVEN PILES

6171

Precast concrete piles including reinforcement, couplings, etc

6172

Precast concrete piles suitable for the following working loads including reinforcement, couplings, etc

6173

?mm Diameter piles

m

Not Priced

6174

? x ?mm Piles

m

Not Priced

6175

? x ?mm Hexagonal piles

m

Not Priced

6176

Piles suitable for ?kN working load

m

Not Priced

6177

Rock shoe for ?mm diameter pile

No

Not Priced

6178

Rock shoe for ? x ?mm pile

No

Not Priced

6179

Rock shoe for ? x ?mm hexagonal pile

No

Not Priced

6180

Rock shoe for pile of ?kN working load

No

Not Priced

6181

Driving only precast concrete piles not exceeding 10m deep in earth below ground level

6182

Driving only precast concrete piles exceeding ?m and not exceeding ?m deep in earth below ground level

6183

Driving only precast concrete piles not exceeding 10m deep in earth below basement level (basement level exceeding ?m and not exceeding ?m below ground level)

6184

Driving only precast concrete piles exceeding ?m and not exceeding ?m deep in earth below basement level (basement level exceeding ?m and not exceeding ?m below ground level)

6185

?mm Diameter piles

m

Not Priced

6186

? x ?mm Piles

m

Not Priced

6187

? x ?mm Hexagonal piles

m

Not Priced

6188

?kN Piles

m

Not Priced

6189

PRECAST CONCRETE PILES IN PRE-DRILLED SHAFTS

Carried forward Bill No 5 Piling ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-62-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

6190

Drilling not exceeding 10 m deep in earth below ground level

6191

Drilling exceeding ?m and not exceeding ?m deep in earth below ground level

6192

Drilling not exceeding 10m deep in earth below basement level (basement level exceeding ?m and not exceeding ?m below ground level)

6193

Drilling exceeding ?m and not exceeding ?m deep in earth below basement level (basement level exceeding ?m and not exceeding ?m below ground level)

6194

Shafts suitable for ?mm diameter piles

m

Not Priced

6195

Shafts suitable for ? x ?mm piles

m

Not Priced

6196

Shafts suitable for ? x ?mm hexagonal piles

m

Not Priced

6197

Shafts suitable for ?kN piles

m

Not Priced

6198

Drilling in strata of a more difficult character

6199

Extra over drilling in earth for drilling in hard rock



Not Priced

6200

Extra over drilling for carting away

6201

Surplus material from pile shafts etc to a dumping site to be located by the contractor



Not Priced

Surplus material from pile shafts etc to a dumping site situated approximately ?km from the building site



Not Priced

6202

6203

Precast concrete piles including reinforcement, couplings, etc (driving to required set elsewhere)

6204

?mm Diameter piles

m

Not Priced

6205

? x ?mm Piles

m

Not Priced

6206

? x ?mm Hexagonal piles

m

Not Priced

6207

Piles suitable for ?kN working load

m

Not Priced

6208

Rock shoe for ?mm diameter pile

No

Not Priced

6209

Rock shoe for ? x ?mm pile

No

Not Priced

Carried forward Bill No 5 Piling ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-63-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

6210

Rock shoe for ? x ?mm hexagonal pile

No

Not Priced

6211

Rock shoe for pile of ?kN working load

No

Not Priced

6212

Driving only precast concrete piles in pre-drilled shafts not exceeding 10m deep in earth below ground level

6213

Driving only precast concrete piles in pre-drilled shafts exceeding ?m and not exceeding ?m deep in earth below ground level

6214

Driving only precast concrete piles in pre-drilled shafts not exceeding 10m deep in earth below basement level (basement level exceeding ?m and not exceeding ?m below ground level)

6215

Driving only precast concrete piles in pre-drilled shafts exceeding ?m and not exceeding ?m deep in earth below basement level (basement level exceeding ?m and not exceeding ?m below ground level)

6216

?mm Diameter piles

m

Not Priced

6217

? x ?mm Piles

m

Not Priced

6218

? x ?mm Hexagonal piles

m

Not Priced

6219

?kN Piles

m

Not Priced

6220

IN-SITU CONCRETE AUGERED PILES

6221

Drilling not exceeding 10m deep in earth below ground level

6222

Drilling exceeding ?m and not exceeding ?m deep in earth below ground level

6223

Drilling not exceeding 10m deep in earth below basement level (basement level exceeding ?m and not exceeding ?m below ground level)

6224

Drilling exceeding ?m and not exceeding ?m deep in earth below basement level (basement level exceeding ?m and not exceeding ?m below ground level)

6225

?mm Diameter pile shafts

m

Not Priced

6226

?mm Diameter raking pile shafts

m

Not Priced

Carried forward Bill No 5 Piling ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-64-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 6227

6228

R

Not Priced

Extra over drilling ?mm diameter pile shaft for under-reaming enlarged foot ?mm diameter extreme and ?mm high

No

Not Priced

Extra over drilling ?mm diameter raking pile shaft for under-reaming enlarged foot ?mm diameter extreme and ?mm high

No

Not Priced



Not Priced

6229

Drilling in strata of a more difficult character

6230

Extra over drilling and under-reaming in earth for drilling in hard rock

6231

Extra over drilling for carting away

6232

Surplus material from pile shafts etc to a dumping site to be located by the contractor



Not Priced

Surplus material from pile shafts etc to a dumping site situated approximately ?km from the building site



Not Priced

6233

6234

Casings

6235

Temporary casings to ?mm diameter pile shafts to prevent collapse of excavations, ingress of water, etc including removal

m

Not Priced

Permanent casings to ?mm diameter pile shafts to prevent collapse of excavations, ingress of water, etc

m

Not Priced

6236

6237

?MPa/?mm reinforced concrete

6238

?mm Diameter piles

m

Not Priced

6239

?mm Diameter raking piles

m

Not Priced

6240

Additional concrete in enlarged foot ?mm diameter extreme and ?mm high on ?mm diameter pile

No

Not Priced

Additional concrete in enlarged foot ?mm diameter extreme and ?mm high on ?mm diameter raking pile

No

Not Priced

m

Not Priced

6241

6242

Formwork

6243

Formwork to ?mm diameter pile above ground level

6244

CONTINUOUS FLIGHT AUGER (CFA) IN-SITU CONCRETE PILES

Carried forward Bill No 5 Piling ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-65-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

6245

Continuous flight auger drilling not exceeding 10m deep in earth below ground level

6246

Continuous flight auger drilling exceeding ?m and not exceeding ?m deep in earth below ground level

6247

Continuous flight auger drilling not exceeding 10m deep in earth below basement level (basement level exceeding ?m and not exceeding ?m below ground level)

6248

Continuous flight auger drilling exceeding ?m and not exceeding ?m deep in earth below basement level (basement level exceeding ?m and not exceeding ?m below ground level)

6249

?mm Diameter pile shafts

m

Not Priced

6250

?mm Diameter raking pile shafts

m

Not Priced

6251

Continuous flight auger drilling in strata of a more difficult character

6252

Extra over continuous flight auger drilling in earth for continuous flight auger drilling in hard rock



Not Priced

6253

Extra over continuous flight auger drilling for carting away

6254

Surplus material from pile shafts etc to a dumping site to be located by the contractor



Not Priced

Surplus material from pile shafts etc to a dumping site situated approximately ?km from the building site



Not Priced

6255

6256

?MPa/?mm cement/sand grout (reinforced concrete?) to continuous flight auger piles

6257

?mm Diameter piles

m

Not Priced

6258

?mm Diameter raking piles

m

Not Priced

6259

IN-SITU CONCRETE DRIVEN PILES

6260

Driving or boring not exceeding 10m deep in earth below ground level

6261

Driving or boring exceeding ?m and not exceeding ?m deep in earth below ground level

Carried forward Bill No 5 Piling ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-66-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

6262

Driving or boring not exceeding 10m deep in earth below basement level (basement level exceeding ?m and not exceeding ?m below ground level)

6263

Driving or boring exceeding ?m and not exceeding ?m deep in earth below basement level (basement level exceeding ?m and not exceeding ?m below ground level)

6264

?mm Diameter pile shafts

m

Not Priced

6265

?mm Diameter raking pile shafts

m

Not Priced

6266

Extra over boring for carting away

6267

Surplus material from pile shafts etc to a dumping site to be located by the contractor



Not Priced

Surplus material from pile shafts etc to a dumping site situated approximately ?km from the building site



Not Priced

6268

6269

?MPa/?mm reinforced concrete

6270

?mm Diameter piles

m

Not Priced

6271

?mm Diameter raking piles

m

Not Priced

6272

?mm Diameter expanded bulb at bottom of ?mm diameter pile

No

Not Priced

?mm Diameter expanded bulb at bottom of ?mm diameter raking pile

No

Not Priced

m

Not Priced

6273

6274

Formwork

6275

Formwork to ?mm diameter pile above ground level

6276

PILES DESIGNED BY THE CONTRACTOR

6277

Piles suitable for the following working loads etc including concrete, precast concrete, reinforcement, couplings, drilling, driving or boring, etc complete

6278

Not exceeding 100kN

No

Not Priced

6279

Exceeding 100kN and not exceeding 200kN

No

Not Priced

6280

Exceeding ?kN and not exceeding ?kN

No

Not Priced

6281

Not exceeding 100kN (shear force ?kN)

No

Not Priced

Carried forward Bill No 5 Piling ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-67-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

6282

Exceeding ?kN and not exceeding ?kN (shear force ?kN)

No

Not Priced

6283

Not exceeding 100kN (tension load ?kN)

No

Not Priced

6284

Exceeding ?kN and not exceeding ?kN (tension load ?kN)

No

Not Priced

6285

Not exceeding 100kN (shear force ?kN, tension load ?kN)

No

Not Priced

6286

Exceeding ?kN and not exceeding ?kN (shear force ?kN, tension load ?kN)

No

Not Priced

No

Not Priced

6287

TEST CUBES

6288

Making and testing 150 x 150 x 150mm concrete strength test cube (Provisional)

6289

REINFORCEMENT

6290

REINFORCEMENT (PROVISIONAL)

6291

Mild steel reinforcement

6292

?mm Diameter bars

t

Not Priced

6293

?mm Diameter bars in lengths exceeding 13m and not exceeding 18m

t

Not Priced

?mm Diameter bars in lengths exceeding 18m and not exceeding 19m

t

Not Priced

?mm Diameter bars in lengths exceeding ?m and not exceeding ?m

t

Not Priced

6296

?mm Diameter helical bars

t

Not Priced

6297

High tensile steel reinforcement

6298

?mm Diameter bars

t

Not Priced

6299

?mm Diameter bars in lengths exceeding 13m and not exceeding 18m

t

Not Priced

?mm Diameter bars in lengths exceeding 18m and not exceeding 19m

t

Not Priced

?mm Diameter bars in lengths exceeding ?m and not exceeding ?m

t

Not Priced

?mm Diameter helical bars

t

Not Priced

6294

6295

6300

6301

6302

Carried forward Bill No 5 Piling ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-68-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

6303

Mild steel reinforcement in continuous flight auger piles

6304

?mm Diameter bars

t

Not Priced

6305

?mm Diameter bars in lengths exceeding 13m and not exceeding 18m

t

Not Priced

?mm Diameter bars in lengths exceeding 18m and not exceeding 19m

t

Not Priced

?mm Diameter bars in lengths exceeding ?m and not exceeding ?m

t

Not Priced

6308

?mm Diameter helical bars

t

Not Priced

6309

High tensile steel reinforcement in continuous flight auger piles

6310

?mm Diameter bars

t

Not Priced

6311

?mm Diameter bars in lengths exceeding 13m and not exceeding 18m

t

Not Priced

?mm Diameter bars in lengths exceeding 18m and not exceeding 19m

t

Not Priced

?mm Diameter bars in lengths exceeding ?m and not exceeding ?m

t

Not Priced

6314

?mm Diameter helical bars

t

Not Priced

6315

EXPOSING PILES FOR INSPECTION

6316

Exposing pile for inspection including excavation ?m deep in earth and backfilling

No

Not Priced

Exposing pile for inspection including excavation ?m deep in earth and backfilling compacted to ?

No

Not Priced

6306

6307

6312

6313

6317

6318

TRIMMING ETC

6319

User note

6320

Trimming will in most instances be done by the main contractor The following items are therefore also repeated in Concrete Sundries

Carried forward Bill No 5 Piling ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-69-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

6321

Stripping back head of concrete pile for a height not exceeding ?mm to expose reinforcement, including trimming to defined level and bending reinforcement as necessary for casting into pile cap

6322

Cutting off and removing excess length of precast concrete pile as necessary, including stripping back for a height not exceeding ?mm to expose reinforcement, trimming to defined level and bending reinforcement as necessary for casting into pile cap

6323

?mm Diameter pile

No

Not Priced

6324

? x ?mm Pile

No

Not Priced

6325

? x ?mm Hexagonal pile

No

Not Priced

6326

Pile not exceeding ?kN

No

Not Priced

6327

Pile exceeding ?kN and not exceeding ?kN

No

Not Priced

6328

TESTING

6329

Transporting to and establishment on site of necessary testing plant for the execution of the work and removal thereof on completion

Item

Not Priced

6330

Testing ? pile to a maximum load of ?kN

No

Not Priced

6331

Installing ?mm diameter pile to a depth not exceeding ?m below ground level and testing to a maximum load of ?kN

No

Not Priced

Integrity testing in-situ concrete pile

No

Not Priced

6332

Carried to summary Bill No 5 Piling ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-70-

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

311

BILL NO ?

312

CONCRETE, FORMWORK AND REINFORCEMENT

313

SUPPLEMENTARY PREAMBLES

314

Cost of tests

315

The costs of making, storing and testing of concrete test cubes as required under clause 7 "Tests" of SABS 1200 G shall include the cost of providing cube moulds necessary for the purpose, for testing costs and for submitting reports on the tests to the principal agent. The testing shall be undertaken by an independent firm or institution nominated by the contractor to the approval of the principal agent. (Test cubes are measured separately)

316

Breeze concrete

317

Breeze concrete shall consist of twelve parts clean dry furnace ash, free from coal or other foreign matter, to one part cement (1:12); the ash graded up to particles which will pass a 16,5mm ring from a minimum which fails to pass a 4,75mm mesh. The finer materials from the screening are to be first mixed with the cement into a mortar and the ash added afterwards and thoroughly incorporated

318

Lightweight concrete

319

Lightweight concrete shall have a density of 600kg/m3 for the top 50mm and 400kg/m3 for the remaining thickness. The minimum thickness at outlets, channels, etc shall be 50mm

320

Formwork

321

Descriptions of formwork shall be deemed to include use and waste only (except where described as "left in" or "permanent"), for fitting together in the required forms, wedging, plumbing and fixing to true angles and surfaces as necessary to ensure easy release during stripping and for reconditioning as necessary before re-use

322

The vertical strutting shall be carried down to such construction as is sufficiently strong to afford the required support without damage and shall remain in position until the newly constructed work is able to support itself

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-71-

Quantity

Rate

Amount

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

323

Formwork to soffits of solid slabs etc shall be deemed to be to slabs not exceeding 250mm thick unless otherwise described

324

Formwork to soffits of slabs, beams, etc shall be deemed to be propped up exceeding 1,5m and not exceeding 3,5m high unless otherwise described

325

Formwork to sides of bases, pile caps, ground beams, etc will only be measured where it is prescribed by the engineer for design reasons. Formwork necessitated by irregularity or collapse of excavated faces will not be measured and the cost thereof shall be deemed to be included in the allowance for taking the risk of collapse of the sides of the excavations, provision for which is made in "Earthworks"

326

User Note

327

In order to accommodate the custom in some regions to give formwork to sides of beams, isolated beams, etc separately from formwork to the soffits thereof, the items in respect of formwork to beams, isolated beams, etc are given under the headings of "formwork to sides", "formwork to soffits" and "formwork to sides and soffits"

328

LIGHTWEIGHT CONCRETE

329

Breeze concrete

330

Grading to slabs



Not Priced

331

Finishing smooth top surfaces of grading to falls for waterproofing including 1:8 monolithic cement plaster screed as necessary



Not Priced

Finishing smooth top surfaces of grading to falls and currents for waterproofing including 1:8 monolithic cement plaster screed as necessary



Not Priced

? x ?mm 1:8 Cement plaster triangular fillets against walls etc

m

Not Priced

332

333

334

Lightweight concrete

335

Grading to slabs



Not Priced

336

Finishing smooth top surfaces of grading to falls for waterproofing



Not Priced

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-72-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 337

Finishing smooth top surfaces of grading to falls and currents for waterproofing

R

Not Priced



Not Priced

m

Not Priced

338

? x ?mm Triangular fillets against walls etc

339

UNREINFORCED CONCRETE CAST ON/IN FORMWORK

340

UNREINFORCED CONCRETE CAST AGAINST EXCAVATED SURFACES

341

"No fines" concrete

342

Class ? concrete

343

?MPa/?mm concrete

344

Surface blinding under surface beds



Not Priced

345

Surface blinding under footings and bases



Not Priced

346

Drainage columns behind retaining walls



Not Priced

347

Strip footings



Not Priced

348

Surface beds



Not Priced

349

Surface beds cast in panels



Not Priced

350

Surface beds on waterproofing



Not Priced

351

Surface beds cast in panels on waterproofing



Not Priced

352

Pavings



Not Priced

353

Pavings cast in panels



Not Priced

354

Ramps



Not Priced

355

Bottoms and sides of floor ducts



Not Priced

356

Machine bases



Not Priced

357

Steps, urinal steps, cupboard platforms, etc



Not Priced

358

REINFORCED CONCRETE CAST ON/IN FORMWORK

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-73-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

359

REINFORCED CONCRETE CAST AGAINST EXCAVATED SURFACES

360

?MPa/?mm concrete

361

Strip footings



Not Priced

362

Bases



Not Priced

363

Pile caps



Not Priced

364

Foundation beams



Not Priced

365

Surface beds



Not Priced

366

Surface beds cast in panels



Not Priced

367

Surface beds on waterproofing



Not Priced

368

Surface beds cast in panels on waterproofing



Not Priced

369

Pavings



Not Priced

370

Pavings cast in panels



Not Priced

371

Bottoms and sides of floor ducts



Not Priced

372

Slabs including beams and inverted beams



Not Priced

373

Pre-stressed slabs including beams and inverted beams



Not Priced

374

Stepped slabs including beams and inverted beams



Not Priced

375

Raking slabs, ramps, etc including beams and inverted beams



Not Priced

376

Coffered slabs including beams and inverted beams



Not Priced

377

Troughed slabs including beams and inverted beams



Not Priced

378

Composite hollow block slabs including beams and inverted beams



Not Priced

Composite prefabricated beam and trough slabs including beams and inverted beams



Not Priced

380

Hood slabs



Not Priced

381

Vanity slabs, cupboard slabs, cover slabs, etc



Not Priced

379

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-74-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

382

Isolated beams



Not Priced

383

Bottoms and sides of isolated gutter beams



Not Priced

384

Lintels



Not Priced

385

Stairs including landings, beams and inverted beams



Not Priced

386

Retaining walls in foundations (Provisional)



Not Priced

387

Retaining walls



Not Priced

388

Walls in foundations (Provisional)



Not Priced

389

Walls



Not Priced

390

Balustrade walls



Not Priced

391

Columns in foundations (Provisional)



Not Priced

392

Columns



Not Priced

393

TEST CUBES

394

Making and testing 150 x 150 x 150mm concrete strength test cube (Provisional)

No

Not Priced

No

Not Priced

395

User note

396

In lieu of the above the requirements in respect of quality control can be described and the total volume of concrete subject to control given in cubic meters (normally the reinforced concrete only). There are specialist companies who offer a control service based on a rate per cubic meter

397

CONCRETE SUNDRIES

398

Stripping back heads of concrete piles for a height not exceeding ?mm to expose reinforcement including trimming to defined levels and bending reinforcement as necessary for casting into pile caps

399

Cutting off and removing excess length of precast concrete pile as necessary including stripping back for a height not exceeding ?mm to expose reinforcement, trimming to defined level and bending reinforcement as necessary for casting into pile cap

400

?mm Diameter pile

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-75-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

401

? x ?mm Pile

No

Not Priced

402

? x ?mm Hexagonal pile

No

Not Priced

403

Pile not exceeding ?kN

No

Not Priced

404

Pile exceeding ?kN and not exceeding ?kN

No

Not Priced

Curing surfaces of concrete with ? curing compound applied at a rate of ? l/m² 406

Horizontal top surfaces



Not Priced

407

Vertical surfaces



Not Priced

408

Finishing top surfaces of concrete smooth with a wood float

409

Finishing top surfaces of concrete smooth with a steel trowel

410

Finishing top surfaces of concrete smooth with a power float

411

Finishing top surfaces of concrete to an evenly ribbed non-slip surface Finishing top surfaces of concrete smooth with a power float with high quality grey (ivory etc?) non-metalic commercial hardener added (7kg/m² in two operations), curing with curing compound at a rate of 7-10m²/l, subsequently removing curing compound and sealing with suitable sealer at a rate of 7m²/l

413

Surface beds, slabs, etc



Not Priced

414

Surface beds, slabs, etc to falls



Not Priced

415

Surface beds, slabs, etc to falls and currents



Not Priced

416

Pavings to falls



Not Priced

417

Pavings to falls and currents



Not Priced

418

Tops of beams, walls, etc



Not Priced

419

Sloping and splayed tops of beams, walls, etc



Not Priced

420

Wire brushing of concrete surfaces to expose aggregate

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-76-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

421

Sandblasting of concrete surfaces to expose aggregate

422

Bush-hammering of concrete surfaces to expose aggregate

423

Sides of walls



Not Priced

424

Sides of columns



Not Priced

425

Soffits of slabs



Not Priced

426

Sides and soffits of beams



Not Priced

427

Grooves, channels, mortices, sinkings, etc in concrete

428

? x ?mm Grooves in top

m

Not Priced

429

? x ?mm Channels in top

m

Not Priced

430

? x Average ?mm segmental channels in top

m

Not Priced

431

Mortice in top, side, etc not exceeding 150mm deep

No

Not Priced

432

? x ? x ?mm Sinking in top

No

Not Priced

433

? MPa non-shrink grout

434

Bedding approximately ?mm thick under ? x ?mm base plate including chamfered edges all round

No

Not Priced



Not Priced

m

Not Priced

435

HOLLOW BLOCKS ETC

436

? spacing tiles to soffits of composite slabs

437

Solid areas

438

Ribs ?mm wide

439

? hollow blocks in composite slabs

440

? x ? x ?mm Block type ? laid end to end in rows

No

Not Priced

441

? x ? x ?mm Block type ? laid ?mm apart in both directions

No

Not Priced

442

PREFABRICATED CONCRETE BEAMS

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-77-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

443

"?" prefabricated prestressed concrete beams in composite slabs

444

? x ?mm Beams with ? ?mm reinforcing wires, in lengths not exceeding 5m

m

Not Priced

? x ?mm Beams with ? ?mm reinforcing wires, in lengths exceeding 5m and not exceeding 7,5m

m

Not Priced

? x ?mm Beams with ? ?mm reinforcing wires, in lengths exceeding ?m and not exceeding ?m

m

Not Priced

445

446

447

PREFABRICATED BLOCK BEAMS

448

"?" type ? prefabricated block beams in composite slabs

449

? x ?mm Beams with ? ?mm reinforcing bars, in lengths not exceeding 5m

m

Not Priced

? x ?mm Beams with ? ?mm reinforcing bars, in lengths exceeding 5m and not exceeding 7,5m

m

Not Priced

? x ?mm Beams with ? ?mm reinforcing bars, in lengths exceeding ?m and not exceeding ?m

m

Not Priced

450

451

452

ROUGH FORMWORK (DEGREE OF ACCURACY III)

453

Rough formwork to sides

454

Strip footings (Provisional)



Not Priced

455

Bases (Provisional)



Not Priced

456

Pile caps (Provisional)



Not Priced

457

Foundation beams (Provisional)



Not Priced

458

ROUGH FORMWORK (DEGREE OF ACCURACY II)

459

ROUGH FORMWORK TO ? TYPICAL FLOORS (DEGREE OF ACCURACY II)

460

SMOOTH FORMWORK (DEGREE OF ACCURACY II)

461

SMOOTH FORMWORK (DEGREE OF ACCURACY I)

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-78-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

462

SMOOTH FORMWORK TO ? TYPICAL FLOORS (DEGREE OF ACCURACY I)

463

SPECIAL FORMWORK (DEGREE OF ACCURACY I)

464

SPECIAL FORMWORK TO ? TYPICAL FLOORS (DEGREE OF ACCURACY I)

465

User note

466

The formwork subheadings throughout are to be preceded by appropriate main headings

467

Rough formwork to sides

468

Extra over rough formwork to sides for smooth formwork

469

Extra over rough formwork to sides for special formwork

470

Smooth formwork to sides

471

Special formwork to sides

472

Steps



Not Priced

473

Retaining walls



Not Priced

474

Retaining walls circular to (not?) exceeding 1m radius



Not Priced

475

Retaining walls with total height exceeding ?m and not exceeding ?m above bearing level



Not Priced

Retaining walls with total height exceeding ?m and not exceeding ?m above bearing level circular to (not?) exceeding 1m radius



Not Priced

One face of retaining walls (other face against excavated or existing surfaces)



Not Priced

One face of retaining walls (other face against excavated or existing surfaces) circular to (not?) exceeding 1m radius



Not Priced

479

Walls in foundations (Provisional)



Not Priced

480

Walls in foundations circular to (not?) exceeding 1m radius (Provisional)



Not Priced

Walls



Not Priced

476

477

478

481

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-79-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

482

Walls circular to (not?) exceeding 1m radius



Not Priced

483

Walls with total height exceeding ?m and not exceeding ?m above bearing level



Not Priced

Walls with total height exceeding ?m and not exceeding ?m above bearing level circular to (not?) exceeding 1m radius



Not Priced

485

Inner face of shaft walls



Not Priced

486

Outer face of walls flush with perimeter of concrete structure



Not Priced

487

Outer face of walls flush with perimeter of concrete structure circular to (not?) exceeding 1m radius



Not Priced

488

Inner face of balustrade walls



Not Priced

489

Inner face of balustrade walls circular to (not?) exceeding 1m radius



Not Priced

490

Outer face of balustrade walls



Not Priced

491

Outer face of balustrade walls circular to (not?) exceeding 1m radius



Not Priced

492

Inner face of raking balustrade walls over stairs



Not Priced

493

Outer face of raking balustrade walls



Not Priced

494

Inner face of flowing balustrade walls over stairs circular to (not?) exceeding 1m radius



Not Priced

Outer face of flowing balustrade walls circular to (not?) exceeding 1m radius



Not Priced

496

Rectangular stub columns in foundations (Provisional)



Not Priced

497

Rectangular columns in foundations (Provisional)



Not Priced

498

Rectangular columns



Not Priced

499

Rectangular columns with total height exceeding ?m and not exceeding ?m above bearing level



Not Priced

Rectangular columns with one face against excavated or existing surfaces in foundations (Provisional)



Not Priced

Rectangular columns with one face against excavated or existing surfaces



Not Priced

484

495

500

501

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-80-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

502

Rectangular columns with one side splayed



Not Priced

503

Rectangular columns with one side battered



Not Priced

504

Rectangular fins



Not Priced

505

L-shaped columns in foundations (Provisional)



Not Priced

506

L-shaped columns



Not Priced

507

L-shaped columns with total height exceeding ?m and not exceeding ?m above bearing level



Not Priced

508

Irregular L-shaped columns in foundations (Provisional)



Not Priced

509

Irregular L-shaped columns



Not Priced

510

T-shaped columns in foundations (Provisional)



Not Priced

511

T-shaped columns



Not Priced

512

T-shaped columns with total height exceeding ?m and not exceeding ?m above bearing level



Not Priced

513

Irregular T-shaped columns in foundations (Provisional)



Not Priced

514

Irregular T-shaped columns



Not Priced

515

Hexagonal columns in foundations (Provisional)



Not Priced

516

Hexagonal columns



Not Priced

517

Irregular shaped columns with ? right angles and ? obtuse angles in foundations (Provisional)



Not Priced

Irregular shaped columns with ? right angles and ? obtuse angles



Not Priced

519

Beams



Not Priced

520

Beams circular to (not?) exceeding 1m radius



Not Priced

521

Sloping beams



Not Priced

522

Beams with tapering sides



Not Priced

523

Inverted beams



Not Priced

524

Inverted beams circular to (not?) exceeding 1m radius



Not Priced

518

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-81-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

525

Inverted beams above concrete



Not Priced

526

Inverted beams above concrete circular to (not?) exceeding 1m radius



Not Priced

527

Inverted beams with battered sides



Not Priced

528

Inverted beams with battered sides, above concrete



Not Priced

529

Isolated beams



Not Priced

530

Isolated beams circular to (not?) exceeding 1m radius



Not Priced

531

Sloping isolated beams



Not Priced

532

Wall beams



Not Priced

533

Isolated wall beams



Not Priced

534

Isolated wall beams circular to (not?) exceeding 1m radius



Not Priced

535

Inner faces of isolated gutter beams



Not Priced

536

Lintels



Not Priced

537

Wallholds



Not Priced

538

Edges exceeding 300mm high



Not Priced

539

Edges exceeding 300mm high circular to (not?) exceeding 1m radius



Not Priced

Edges, risers, ends and reveals not exceeding 300mm high or wide

m

Not Priced

Edges, risers, ends and reveals not exceeding 300mm high or wide circular to (not?) exceeding 1m radius

m

Not Priced

Sloping and stepped outer edges of stairs not exceeding 300mm high extreme

m

Not Priced

Sloping and stepped outer edges of stairs ?mm high extreme

m

Not Priced

Sloping and stepped inner edges of kerbs to stairs not exceeding 300mm high extreme

m

Not Priced

Flowing and stepped outer edges of stairs ?mm high extreme circular to (not?) exceeding 1m radius

m

Not Priced

540

541

542

543

544

545

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-82-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 546

547

548

Flowing and stepped inner edges of kerbs to stairs not exceeding 300mm high extreme circular to (not?) exceeding 1m radius

R

Not Priced

m

Not Priced

Frustrum of a pyramid shaped column cap ? x ?mm at top, ? x ?mm at bottom and ?mm high overall, with top ?mm of cap vertical

No

Not Priced

Frustrum of a cone shaped column cap ?mm diameter at bottom, ?mm diameter at top and ?mm high overall, with top ?mm of cap vertical

No

Not Priced

549

Rough formwork to circular columns

550

Smooth formwork to circular columns

551

Special formwork to circular columns

552

?mm Diameter column ?m high

No

Not Priced

553

?mm Diameter column ?m high with cap ? x ? x ?mm high

No

Not Priced

554

?mm Diameter column ?m high with mushroom cap ?mm diameter at top and ?mm high overall with the top ?mm of cap vertical

No

Not Priced

555

Rough formwork to soffits

556

Extra over rough formwork to soffits for smooth formwork

557

Extra over rough formwork to soffits for special formwork

558

Smooth formwork to soffits

559

Special formwork to soffits

560

Post-tensioned slabs



Not Priced

561

Post-tensioned slabs propped up exceeding ?m and not exceeding ?m high



Not Priced

562

Slabs



Not Priced

563

Slabs propped up not exceeding 1,5m high



Not Priced

564

Slabs propped up exceeding ?m and not exceeding ?m high m²

Not Priced

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-83-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

565

User note

566

The following two items are to be given only in instances where supports to concrete are required to be left in for periods exceeding those provided for in the preambles

567

Slabs with props left in position for a period of ? days



Not Priced

568

Slabs with props left in position for a period of ? days after casting of slab over



Not Priced

569

Slabs propped off sloping surface



Not Priced

570

Slabs propped up exceeding ?m and not exceeding ?m high off sloping surface



Not Priced

571

Slabs exceeding ?mm and not exceeding ?mm thick



Not Priced

572

Slabs exceeding ?mm and not exceeding ?mm thick propped up not exceeding 1,5m high



Not Priced

Slabs exceeding ?mm and not exceeding ?mm thick propped up exceeding ?m and not exceeding ?m high



Not Priced

574

Slabs over shafts



Not Priced

575

Slabs with sloping soffits



Not Priced

576

Slabs with sloping soffits propped up not exceeding 1,5m high



Not Priced

Slabs with sloping soffits propped up exceeding ?m and not exceeding ?m high



Not Priced

Slabs with sloping soffits exceeding ?mm and not exceeding ?mm thick



Not Priced

Slabs with sloping soffits exceeding ?mm and not exceeding ?mm thick propped up not exceeding 1,5m high



Not Priced

Slabs with sloping soffits exceeding ?mm and not exceeding ?mm thick propped up exceeding ?m and not exceeding ?m high



Not Priced

581

Cantilever slabs



Not Priced

582

Cantilever slabs propped up not exceeding 1,5m high



Not Priced

573

577

578

579

580

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-84-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 583

R

Not Priced

Cantilever slabs propped up exceeding ?m and not exceeding ?m high



Not Priced

584

Hood slabs



Not Priced

585

Cupboard slabs, cover slabs, etc



Not Priced

586

Vanity slabs, cupboard slabs, cover slabs, etc propped up not exceeding 1,5m high



Not Priced

587

Landings



Not Priced

588

Landings exceeding ?mm and not exceeding ?mm thick



Not Priced

589

Stairs with sloping soffits



Not Priced

590

Beams



Not Priced

591

Beams propped up not exceeding 1,5m high



Not Priced

592

Beams propped up exceeding ?m and not exceeding ?m high



Not Priced

593

Beams circular to (not?) exceeding 1m radius



Not Priced

594

Beams circular to (not?) exceeding 1m radius, propped up exceeding ?m and not exceeding ?m high



Not Priced

595

User note

596

The following two items are to be given only in instances where supports to concrete are required to be left in for periods exceeding those provided for in the preambles

597

Beams with props left in position for a period of ? days



Not Priced

598

Beams with props left in position for a period of ? days after casting of beam over



Not Priced

599

Beams with sloping soffits



Not Priced

600

Beams with sloping soffits propped up not exceeding 1,5m high



Not Priced

Beams with sloping soffits propped up exceeding ?m and not exceeding ?m high



Not Priced

Isolated beams



Not Priced

601

602

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-85-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

603

Isolated beams propped up not exceeding 1,5m high



Not Priced

604

Isolated beams propped up exceeding ?m and not exceeding ?m high



Not Priced

605

Isolated beams circular to (not?) exceeding 1m radius



Not Priced

606

Isolated beams circular to (not?) exceeding 1m radius, propped up exceeding ?m and not exceeding ?m high



Not Priced

607

Isolated beams with sloping soffits



Not Priced

608

Isolated beams with sloping soffits propped up not exceeding 1,5m high



Not Priced

Isolated beams with sloping soffts propped up exceeding ?m and not exceeding ?m high



Not Priced

610

Wall beams over openings



Not Priced

611

Wall beams over openings propped up not exceeding 1,5m high



Not Priced

Wall beams over openings propped up exceeding ?m and not exceeding ?m high



Not Priced

613

Isolated wall beams over openings



Not Priced

614

Isolated wall beams over openings propped up not exceeding 1,5m high



Not Priced

Isolated wall beams over openings propped up exceeding ?m and not exceeding ?m high



Not Priced

609

612

615

616

Rough formwork to composite hollow block slabs

617

Soffits of composite slabs



Not Priced

618

Soffits of composite slabs propped up not exceeding 1,5m high



Not Priced

Soffits of composite slabs propped up exceeding ?m and not exceeding ?m high



Not Priced

619

620

Rough formwork to coffered slabs

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-86-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

621

Smooth formwork to coffered slabs

622

Soffits of coffered slabs with ?mm wide ribs at ?mm centres in both directions



Not Priced

Soffits of coffered slabs with ?mm wide ribs at ?mm centres in both directions propped up not exceeding 1,5m high



Not Priced

Soffits of coffered slabs with ?mm wide ribs at ?mm centres in both directions propped up exceeding ?m and not exceeding ?m high



Not Priced

Soffits of adjacent flush surfaces of coffered slabs exceeding ?mm and not exceeding ?mm thick



Not Priced

Soffits of adjacent flush surfaces of coffered slabs exceeding ?mm and not exceeding ?mm thick propped up not exceeding 1,5m high



Not Priced

Soffits of adjacent flush surfaces of coffered slabs exceeding ?mm and not exceeding ?mm thick propped up exceeding ?m and not exceeding ?m high



Not Priced

Top and tapered sides of coffer ? x ?mm at top, ? x ?mm at bottom and ?mm high with all corners rounded

No

Not Priced

623

624

625

626

627

628

629

Rough formwork to troughed slabs

630

Smooth formwork to troughed slabs

631

Soffits of troughed slabs with ?mm wide ribs at ?mm centres



Not Priced

632

Soffits of troughed slabs with ?mm wide ribs at ?mm centres propped up not exceeding 1,5m high



Not Priced

Soffits of troughed slabs with ?mm wide ribs at ?mm centres propped up exceeding ?m and not exceeding ?m high



Not Priced

Soffits of adjacent flush surfaces of troughed slabs exceeding ?mm and not exceeding ?mm thick



Not Priced

Soffits of adjacent flush surfaces of troughed slabs exceeding ?mm and not exceeding ?mm thick propped up not exceeding 1,5m high



Not Priced

Soffits of adjacent flush surfaces of troughed slabs exceeding ?mm and not exceeding ?mm thick propped up exceeding ?m and not exceeding ?m high



Not Priced

633

634

635

636

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-87-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 637

Top and sides of troughs ?mm wide at top, ?mm wide at bottom and ?mm high, including stopped ends

R

Not Priced

m

Not Priced

m

Not Priced

638

Rough retractable shutters

639

Shutters ? x ?mm high supported on prefabricated beams

640

Supporting bearers to prefabricated beams

641

Bearers

m

Not Priced

642

Bearers propped up not exceeding 1,5m high

m

Not Priced

643

Bearers propped up exceeding ?mm and not exceeding ?mm high

m

Not Priced

644

Rough formwork to sides and soffits

645

Extra over rough formwork to sides and soffits for smooth formwork

646

Extra over rough formwork to sides and soffits for special formwork

647

Smooth formwork to sides and soffits

648

Special formwork to sides and soffits

649

Beams



Not Priced

650

Beams propped up not exceeding 1,5m high



Not Priced

651

Beams propped up exceeding ?m and not exceeding ?m high



Not Priced

652

Beams circular to (not?) exceeding 1m radius



Not Priced

653

Beams circular to (not?) exceeding 1m radius, propped up not exceeding 1,5m high



Not Priced

Beams circular to (not?) exceeding 1m radius, propped up exceeding ?m and not exceeding ?m high



Not Priced

655

Sloping beams



Not Priced

656

Sloping beams propped up not exceeding 1,5m high



Not Priced

657

Sloping beams propped up exceeding ?m high and not exceeding ?m high



Not Priced

654

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-88-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

658

Beams with battered sides



Not Priced

659

Beams with sloping soffits and tapering sides



Not Priced

660

Beams with sloping soffits and tapering sides propped up not exceeding 1,5m high



Not Priced

Beams with sloping soffits and tapering sides propped up exceeding ?m and not exceeding ?m high



Not Priced

662

Isolated beams



Not Priced

663

Isolated beams propped up not exceeding 1,5m high



Not Priced

664

Isolated beams propped up exceeding ?m and not exceeding ?m high



Not Priced

665

Isolated beams circular to (not?) exceeding 1m radius



Not Priced

666

Isolated beams circular to (not?) exceeding 1m radius, propped up exceeding ?m and not exceeding ?m high



Not Priced

667

Sloping isolated beams



Not Priced

668

Sloping isolated beams propped up not exceeding 1,5m high



Not Priced

Sloping isolated beams propped up exceeding ?m and not exceeding ?m high



Not Priced

670

Isolated gutter beams



Not Priced

671

Isolated gutter beams propped up exceeding ?m and not exceeding ?m high



Not Priced

672

Lintels



Not Priced

673

Lintels propped up not exceeding 1,5m high



Not Priced

674

Lintels propped up exceeding ?m and not exceeding ?m high



Not Priced

661

669

675

Formwork to sloping top surfaces

676

Slabs



Not Priced

677

Beams, walls, etc exceeding 300mm wide



Not Priced

678

Beams, walls, etc not exceeding 300mm wide

m

Not Priced

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-89-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

679

Boxing in rough formwork to form

680

Boxing in smooth formwork to form

681

Boxing in special formwork to form

682

User Note

683

Attention is drawn to the fact that suitable grouping according to size may be adopted in the event of numerous items occurring

684

? x ?mm Chamfers along top or bottom edges

m

Not Priced

685

? x ?mm Chamfers along top or bottom edges, circular to (not?) exceeding 1m radius

m

Not Priced

686

? x ?mm Vertical chamfers at corners

m

Not Priced

687

? x ?mm Horizontal chases or grooves in sides

m

Not Priced

688

? x ?mm Horizontal chases or grooves in sides, circular to (not?) exceeding 1m radius

m

Not Priced

689

? x ?mm Vertical chases or grooves in sides

m

Not Priced

690

? x ?mm Raking chases or grooves in sides

m

Not Priced

691

? x ?mm Extreme twice splayed horizontal chases or grooves in sides

m

Not Priced

? x ?mm Extreme twice splayed vertical chases or grooves in sides

m

Not Priced

693

? x ?mm Rebates in sides along top edges

m

Not Priced

694

? x?mm Rebates in sides along top edges, circular to (not?) exceeding 1m radius

m

Not Priced

695

? x ?mm Rebates in sides along bottom edges

m

Not Priced

696

? x ?mm Rebates in sides along bottom edges, circular to (not?) exceeding 1m radius

m

Not Priced

697

? x ?mm Vertical rebates

m

Not Priced

698

? x ?mm Extreme splayed rebates in sides along top edges

m

Not Priced

692

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-90-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 699

R

Not Priced

? x ?mm Extreme splayed rebates in sides along top edges, circular to (not?) exceeding 1m radius

m

Not Priced

? x ?mm Extreme splayed rebates in sides along bottom edges

m

Not Priced

? x ?mm Extreme splayed rebates in sides along bottom edges, circular to (not?) exceeding 1m radius

m

Not Priced

702

? x ?mm Extreme vertical splayed rebates

m

Not Priced

703

? x ? x ?mm Recess in side

No

Not Priced

704

? x ? x ?mm Recess in soffit

No

Not Priced

705

Boxing out rough formwork to form

706

Boxing out smooth formwork to form

707

Boxing out special formwork to form

708

User Note

709

Attention is drawn to the fact that suitable grouping according to size may be adopted in the event of numerous items occurring

710

? x ? mm High horizontal projections to sides along top edges

m

Not Priced

? x ? mm High horizontal projections to sides along top edges, circular to (not?) exceeding 1m radius

m

Not Priced

? x ? mm High horizontal projections to sides along bottom edges

m

Not Priced

? x ? mm High horizontal projections to sides along bottom edges, circular to (not?) exceeding 1m radius

m

Not Priced

714

? x ? mm High horizontal projections to sides along middle

m

Not Priced

715

? x ? mm High horizontal projections to sides along middle, circular to (not?) exceeding 1m radius

m

Not Priced

716

? x ? mm High raking projections to sides along middle

m

Not Priced

717

? x ? mm Wide vertical projections to sides along middle

m

Not Priced

700

701

711

712

713

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-91-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 718

R

Not Priced

? x ?mm Wide vertical projections to sides at ends or external corners

m

Not Priced

? x ?mm Wide vertical projections to sides at internal corners

m

Not Priced

720

? x ?mm Vertical splays at internal corners

m

Not Priced

721

Rough formwork to form

722

Smooth formwork to form

723

Special formwork to form

724

Opening not exceeding 1m girth through not exceeding 300mm slab

No

Not Priced

725

Opening not exceeding 1m girth through ?mm slab

No

Not Priced

726

Opening exceeding 1m and not exceeding 2m girth through not exceeding 300mm slab

No

Not Priced

Opening exceeding 1m and not exceeding 2m girth through ?mm slab

No

Not Priced

728

?mm Diameter opening through ?mm slab

No

Not Priced

729

Rebated opening not exceeding 1m girth overall through ?mm slab

No

Not Priced

Rebated opening exceeding 1m and not exceeding 2m girth overall through ?mm slab

No

Not Priced

Opening not exceeding 1m girth through not exceeding 300mm wall or beam

No

Not Priced

732

Opening not exceeding 1m girth through ?mm wall or beam

No

Not Priced

733

Opening exceeding 1m and not exceeding 2m girth through not exceeding 300mm wall or beam

No

Not Priced

Opening exceeding 1m and not exceeding 2m girth through ?mm wall or beam

No

Not Priced

735

?mm Diameter opening through ?mm wall or beam

No

Not Priced

736

PERMANENT FORMWORK

719

727

730

731

734

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-92-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

737

1mm (1,2mm?) "?" galvanised steel permanent decking system to soffits

738

Decking for slabs with ends laid on brick walls



Not Priced

739

Decking for slabs fixed to steel bearers, including cutting and fitting around shear studs



Not Priced



Not Priced

m

Not Priced

m

Not Priced



Not Priced

m

Not Priced



Not Priced

740

MOVEMENT JOINTS ETC

741

Two layers of 375 micron dampproof course (One layer of 0,6mm galvanised steel sheet?) in slip joints between horizontal concrete and brick surfaces including cement mortar bed

742

Exceeding 300mm wide

743

Not exceeding 300mm wide

744

Expansion joints with ?mm softboard (bitumen impregnated softboard?) (closed cell expanded polyethylene?) between vertical concrete and brick surfaces

745

Not exceeding 300mm high to edges of surface beds

746

Expansion joints with ?mm softboard (bitumen impregnated softboard?) between vertical concrete surfaces, including necessary formwork

747

Exceeding 300mm wide through columns

748

Not exceeding 300mm wide through columns

749

Exceeding 300mm high through slabs and beams

750

Not exceeding 300mm high through slabs

m

Not Priced

751

Rebated joints ?mm wide x ?mm high overall, through slabs and beams

m

Not Priced

752

Saw-cut joints

753

? x ?mm Saw-cut joints in top of concrete

m

Not Priced

754

? x ?mm Saw-cut joints in top of concrete with the top ?mm increased to ?mm wide

m

Not Priced

755

Vertical (joggle?) construction joints through concrete including thick cement slurry to one face

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-93-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

756

Horizontal (joggle?) construction joints through concrete including thick cement slurry to one face

757

Surface beds not exceeding 300mmm thick

m

Not Priced

758

Slabs not exceeding 300mm thick

m

Not Priced

759

Slabs ?mm thick

m

Not Priced

760

Walls not exceeding 300mm thick

m

Not Priced

761

Walls ?mm thick

m

Not Priced

762

REINFORCEMENT

763

REINFORCEMENT (PROVISIONAL)

764

Mild steel reinforcement to structural concrete work

765

Mild steel reinforcement to structural concrete work in slides

766

High tensile steel reinforcement to structural concrete work

767

High tensile steel reinforcement to structural concrete work in slides

768

?mm Diameter bars

t

Not Priced

769

?mm Diameter bars in lengths exceeding 13m and not exceeding 18m

t

Not Priced

?mm Diameter bars in lengths exceeding 18m and not exceeding 19m

t

Not Priced

?mm Diameter bars in lengths exceeding ?m and not exceeding ?m

t

Not Priced

772

?mm Diameter bars curved

t

Not Priced

773

?mm Diameter bars helical

t

Not Priced

774

High tensile steel dowel bars

775

?mm Diameter dowel bar ?mm long with one end embedded ?mm deep in side of concrete at expansion joint and other end greased and wrapped in polythene sheeting, including hole through formwork

No

Not Priced

770

771

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-94-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 776

Fabric reinforcement

777

User Note

778

The following types of fabric reinforcement are normally specified:

R

Not Priced

Types 100, 193, 245, 311 and 395 779

Type ? fabric reinforcement in concrete surface beds etc



Not Priced

780

Type ? fabric reinforcement in concrete slabs etc



Not Priced

781

Type ? fabric reinforcement in concrete walls



Not Priced

782

Type ? fabric reinforcement in pre-bent cages in concrete foundation beams



Not Priced

m

Not Priced

No

Not Priced

783

POST-TENSIONED REINFORCEMENT

784

POST-TENSIONED REINFORCEMENT (PROVISIONAL)

785

User Note

786

No provision has been made in the "Model Preambles" for post-tentioned reinforcement. Users are therefore advised to include the engineer's comprehensive post-tensioned reinforcement project specification in the bills of quantities and to insert relevant supplementary preambles where necessary The general nature of the work and the general position and accessibility of stressing anchors shall be described The requirements in respect of marking of cable positions are to be described

787

Post-tensioned tendons

788

12,7mm (15,24mm ?) Diameter high tensile steel tendons with 183,7kN (260,7kN?) ultimate breaking strength, including pre-lubricated sheaths, supporting chairs, marking of positions, etc

789

Dead anchor suitable for ?mm tendon, including corrosion protection

Carried forward Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-95-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 790

791

792

793

R

Not Priced

Stressing anchor suitable for ?mm tendon, including helical reinforcement, hole through formwork for tendon, tensioning, re-tensioning as necessary, trimming end of tendon, corrosion protection, forming and filling in recess in concrete and preparing prescribed tensioning records

No

Not Priced

Intermediate stressing anchor suitable for ?mm tendon, including helical reinforcement, hole through formwork for tendon, sleeve, tensioning, re-tensioning as necessary, trimming end of tendon, corrosion protection and preparing prescribed tensioning records

No

Not Priced

Forming temporary tensioning pocket in ?mm concrete slab for intermediate stressing anchor, including filling in at completion

No

Not Priced

Forming temporary tensioning pocket in ?mm concrete slab for set of ? intermediate stressing anchors, including filling in at completion

No

Not Priced

Carried to summary Bill No 6 Concrete, Formwork and Reinforcement ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-96-

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

Quantity

Rate

Amount

794

BILL NO ?

795

PRECAST CONCRETE

796

SUPPLEMENTARY PREAMBLES

797

Sizes

798

Blocks, sills, etc measured linear shall be made in suitable lengths. Large size setting out drawings shall be prepared where necessary and submitted to the principal agent for approval before moulds are made

799

General

800

Where kerbstones, blocks, etc are laid in ground descriptions shall be deemed to include necessary excavation, filling in and ramming

801

User note

802

Where precast concrete copings, sills, beams, facings, claddings, etc are specially designed then the relevant supplementary preambles are to be included here. Items are to be given with brief descriptions referring to detailed drawings annexed to these bills of quantities where necessary

803

PRECAST CONCRETE PAVING

804

User note

805

The following precast concrete paving descriptions are only to be used when paving slabs etc are purpose made to detailed specifications (other than those available ex stock)

806

Paving of ? x ? x ?mm precast concrete paving slabs with ? finish, laid on ?mm thick river sand bed including preparation of ground or filling

807

Paving of slabs laid with ?mm open joints in both directions



Not Priced

808

Paving of slabs laid with butt joints



Not Priced

809

Paving of slabs laid with butt joints, to falls



Not Priced

810

Paving of slabs laid with ?mm wide joints flush pointed with class I mortar



Not Priced

Carried forward Bill No 7 Precast Concrete ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-97-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 811

Paving of slabs laid with ?mm wide joints flush pointed with class 1 mortar, to falls

R

Not Priced



Not Priced

812

Circular cutting

m

Not Priced

813

Finished edges

m

Not Priced

814

Paving of ? x ? x ?mm precast concrete paving slabs with ? finish including bedding, jointing and pointing

815

Paving of slabs laid on ?mm thick mortar bed on concrete with butt joints



Not Priced

Paving of slabs laid on ?mm thick mortar bed on concrete with butt joints, to falls



Not Priced

Paving of slabs laid on ?mm thick mortar bed on concrete with ?mm wide joints flush pointed



Not Priced

Paving of slabs laid on ?mm thick mortar bed on concrete with ?mm wide joints flush pointed, to falls



Not Priced

816

817

818

819

Circular cutting

m

Not Priced

820

Finished edges

m

Not Priced

821

Paving of ? x ? x ?mm precast concrete paving slabs with ? finish

822

Paving on waterproofing to roofs etc, of slabs laid loose with open joints on polythene bags filled with stabilised sand/cement mixture under corners and centre of slabs



Not Priced

Paving on waterproofing to roofs etc, of slabs laid loose with open joints on "?" patent supports under corners and centre of slabs



Not Priced

823

824

Circular cutting

m

Not Priced

825

Finished edges

m

Not Priced

826

PRECAST CONCRETE SLABS ETC

827

User note

828

If information in respect of reinforcement is available, then it may be included in the descriptions where expedient

Carried forward Bill No 7 Precast Concrete ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-98-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

829

Precast concrete left rough from the mould including bedding, jointing and pointing

830

? x ?mm Thick duct cover slabs in suitable lengths, closely butted at ends including bedding edges along both sides (reinforcement elsewhere)

m

Not Priced

? x ?mm Thick seat slabs in ?mm lengths closely butted at ends including bedding edges at ends and along one side (reinforcement elsewhere)

m

Not Priced

? x ?mm Thick counter slabs in ?mm lengths closely butted at ends including bedding edges at ends and along one side (reinforcement elsewhere)

m

Not Priced

? x ? x ?mm Padstone reinforced with and including three 12mm diameter mild steel stirrups each ?mm girth

No

Not Priced

? x ? x ?mm Block with standard steel foot scraper cast into top, laid in ground

No

Not Priced

? x ? x ?mm Thick cover slab including bedding edges all round (reinforcement elsewhere)

No

Not Priced

? x ? x ?mm Thick seat slab including bedding ends (reinforcement elsewhere)

No

Not Priced

? x ? x ?mm High lintel including building in over opening (reinforcement elsewhere)

No

Not Priced

? x ? x ?mm High lintel twice chamfered and once throated along length including building in over opening (reinforcement elsewhere)

No

Not Priced

? x ? x ?mm High beam including bedding ends (reinforcement elsewhere)

No

Not Priced

840

?mm Diameter hole through ?mm thick unit

No

Not Priced

841

? x ?mm Hole through ?mm thick unit

No

Not Priced

842

Notch ?mm girth in ?mm thick unit

No

Not Priced

843

PRECAST CONCRETE COPINGS ETC

844

PRECAST TERRAZZO COPINGS ETC

845

Precast concrete finished smooth on exposed surfaces including bedding, jointing and pointing

831

832

833

834

835

836

837

838

839

Carried forward Bill No 7 Precast Concrete ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-99-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

846

Precast light grey (white etc?) brushed (polished?) terrazzo finished on exposed surfaces including bedding, jointing and pointing

847

Precast brushed (polished?) terrazzo finished on exposed surfaces with OPC white cement mixture pigmented to ? (colour), with ?mm stone selected in the proportion of ?% (colour) and ?% (colour), including bedding, jointing and pointing

848

? x ?mm Thick overall copings weathered on top to ?mm thick along one edge, with drip groove in bottom along one edge

m

Not Priced

? x ?mm Thick overall copings twice weathered on top to ?mm thick along both edges, with drip groove in bottom along both edges

m

Not Priced

? x ?mm Thick overall window sills weathered on top for a width of ?mm to ?mm thick along front edge, with drip groove in bottom

m

Not Priced

? x ?mm Thick overall window sills with ?mm wide weathered rebate in top and drip groove in bottom

m

Not Priced

849

850

851

852

PRECAST TERRAZZO RISERS, TREADS, PERGOLA BEAMS, ETC

853

Precast (colour?) brushed (polished?) terrazzo including bedding, jointing and pointing

854

? x ? x ?mm Thick riser finished on face

No

Not Priced

855

? x ? x ?mm Thick riser finished on face and one end

No

Not Priced

856

? x ? x ?mm Thick tread finished on top, front edge, one end and ?mm wide return along bottom edge, with ? x ?mm non-slip carborundum insert in top

No

Not Priced

? x ?mm Pergola beam ?m long finished all round (reinforcement elsewhere)

No

Not Priced

858

?mm Diameter hole through ?mm thick unit

No

Not Priced

859

? x ?mm Hole through ?mm thick unit

No

Not Priced

860

Notch ?mm girth in ?mm thick unit

No

Not Priced

861

PRECAST CONCRETE CLADDING ETC

857

Carried forward Bill No 7 Precast Concrete ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-100-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

862

Precast concrete wall cladding to external facades, of ?mm thick slabs with ? finish on exposed surfaces and with continuous joints in both directions, including bedding, jointing, pointing, cramps, dowels, mortices and grouting

863

Wall cladding of slabs not exceeding 0,5m² on face



Not Priced

864

Wall cladding of slabs exceeding ?m² and not exceeding ?m² on face



Not Priced

865

Finished edges to ?mm thick wall cladding

m

Not Priced

866

?mm Diameter hole through ?mm thick unit

No

Not Priced

867

? x ?mm Hole through ?mm thick unit

No

Not Priced

868

Notch ?mm girth in ?mm thick unit

No

Not Priced

869

Precast concrete cladding units etc to external facades with ? finish on exposed surfaces, including jointing, pointing with silicone (polyurethane, polysulphide?) sealing compound, cramps, straps, anchor bolts, mortices, etc

870

Unit type ? ? x ?mm high (drawing No ?)

No

Not Priced

871

Joint sealants

872

Silicone (Polyurethane, Polysulphide?) sealing compound in ?mm wide joints between units including backing strips, bond breakers, primer, etc

m

Not Priced

873

Jointing strips, fixing sundries, etc

874

? x ?mm Galvanised steel water bars bedded in and including "?" mastic in vertical grooves between units (grooves elsewhere)

m

Not Priced

? x ?mm Aluminium jointing strips bedded in and including "?" mastic in vertical grooves between units (grooves elsewhere)

m

Not Priced

? x ?mm Galvanised hoop iron strap ?mm girth with one end embedded in precast concrete and other end bent back and twice shot pinned to concrete

No

Not Priced

? x ?mm Galvanised steel flat section bracket ?mm girth, ? holed for bolts and with one end embedded in precast concrete

No

Not Priced

875

876

877

Carried forward Bill No 7 Precast Concrete ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-101-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 878

R

Not Priced

? x ? x ?mm Galvanised steel angle section bracket ?mm long ? holed for bolts

No

Not Priced

879

?mm "?" expansion bolt

No

Not Priced

880

REINFORCEMENT

881

User note

882

Where expedient reinforcement shall be included in the descriptions of precast elements

883

Mild steel reinforcement

884

?mm Diameter bars

t

Not Priced

885

High tensile steel reinforcement

886

?mm Diameter bars

t

Not Priced

887

Fabric reinforcement

888

Type ? fabric reinforcement in precast elements



Not Priced

889

PRECAST CONCRETE WINDOW SURROUNDS

890

General

891

Window surrounds are to be checked at delivery for squareness. Surrounds out of square will be rejected

892

Prices are to include for building into brick walls as single units or combinations of two or more units and for bedding solid all round in mortar and pointing on both sides with square recessed joints

893

Note: Aluminium infill windows, glazing and pointing with sealing compound are measured elsewhere

894

User note

895

Selected examples of typical items with trade names are provided to show possible ways of describing such items. Users must adapt these examples to suit their particular circumstances

Carried forward Bill No 7 Precast Concrete ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-102-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

896

"Winblok" modular precast concrete window surrounds etc finished smooth on exposed surfaces, including bedding, jointing and pointing

897

590 x 590 x 260mm Type WA 260 window surround

No

Not Priced

898

? x ? x ?mm Type ? window surround

No

Not Priced

899

590 x 590 x 260mm Type WA Q260 quadrant window surround

No

Not Priced

900

? x ? x ?mm Type ? triangular window surround

No

Not Priced

901

515 x 515 x 40mm Type WAP flush infill panel fixed in surround with non-ascetic silicone

No

Not Priced

902

PRECAST CONCRETE FENCING

903

User note

904

See External Works for precast concrete fencing

Carried to summary Bill No 7 Precast Concrete ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-103-

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

905

BILL NO ?

906

MASONRY

907

SUPPLEMENTARY PREAMBLES

908

BRICKWORK

909

Sizes in descriptions

910

Where sizes in descriptions are given in brick units, "one brick" shall represent the length and "half brick" the width of a brick

911

Hollow walls

912

Descriptions of hollow walls shall be deemed to include leaving every fifth perpend of the bottom course of the external skin open as a weep hole

913

User note

914

The following preamble generally applies for works in hot and humid coastal areas

915

Bagged and sealed walls

916

Walls in two skins described as "bagged and sealed" shall be deemed to include having the outer face of the inner skin bagged with 1:6 cement and sand mixture and sealed with two coats bitumen emulsion waterproofing coating

917

Face bricks

918

Bricks shall be ordered timeously to obtain uniformity in size and colour

919

Pointing

920

Descriptions of recessed pointing to fair face brickwork and face brickwork shall be deemed to include square recessed, hollow recessed, weathered pointing, etc

921

BLOCKWORK

922

Concrete masonry units

923

Blocks are to be either solid or hollow modular dense concrete masonry units having a compressive strength of 7MPa

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-104-

Quantity

Rate

Amount

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 924

Wall ties for blockwork

925

Wall ties shall be polypropylene ties complying with BS 76377. Ties for hollow walls shall be of sufficient length to allow not less than 75mm of each end to be built into the blockwork. Ties are to be spaced at intervals of not more than 1m in the horizontal direction and not more than 400mm staggered in the vertical direction except at openings, vertical joints or ends of walls where they are to be placed vertically above each other

926

Blockwork

927

Blockwork shall comply with SANS 10145 "Concrete Masonry Construction"

928

Surfaces to be plastered shall have joints raked out to a depth of at least 10mm to provide a key. Cavities of hollow walls shall be kept free of mortar droppings or other undesirable matter. Every second perpend of the bottom course of the external skin of hollow walls shall be left open as a weep hole

929

Standard complementary blocks

930

Descriptions of blockwork shall be deemed to include standard complementary blocks such as corner, three-quarter, half and quarter blocks required in the construction of corners, reveals, jambs, ends, etc to solid and hollow walls and for bonding as necessary

931

DECORATIVE BLOCKS

932

Blocks shall be of approved manufacture, sound, well burnt or cured and uniform and true in size, shape and colour

933

BRICKWORK

934

FOUNDATIONS (PROVISIONAL)

935

SUPERSTRUCTURE

936

Brickwork of NFP bricks in class II mortar

937

Brickwork of NFX bricks (14 MPa nominal compressive strength) in class II mortar

938

Brickwork of NFX bricks (14 MPa nominal compressive strength) in class II mortar in loadbearing walls etc

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-105-

R

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

939

Brickwork of concrete bricks in class II mortar

940

Brickwork of calcium silicate bricks in class II mortar

941

Piers



Not Priced

942

L-shaped piers



Not Priced

943

H-shaped piers



Not Priced

944

?mm Cut linings to concrete



Not Priced

945

?mm Cut linings to concrete, circular on plan



Not Priced

946

Brick-on-edge walls



Not Priced

947

Half brick walls



Not Priced

948

Half brick walls circular on plan



Not Priced

949

Half brick walls in hollow columns



Not Priced

950

Half brick walls against existing surfaces



Not Priced

951

Half brick walls against waterproofing



Not Priced

952

Half brick walls against waterproofing, circular on plan



Not Priced

953

Half brick walls in beamfilling



Not Priced

954

Half brick walls in beamfilling, circular on plan



Not Priced

955

Half brick linings to concrete



Not Priced

956

Half brick linings to concrete, circular on plan



Not Priced

957

Half brick linings ?mm away from concrete



Not Priced

958

Half brick linings ?mm away from concrete, circular on plan



Not Priced

959

One brick walls



Not Priced

960

One brick walls circular on plan



Not Priced

961

One brick walls in hollow columns



Not Priced

962

One brick walls against existing surfaces



Not Priced

963

One brick walls in beamfilling



Not Priced

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-106-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

964

One brick walls in beamfilling, circular on plan



Not Priced

965

One brick walls of two half brick skins with inner skin bagged and sealed



Not Priced

966

?mm Hollow walls of two half brick skins (no wire ties)



Not Priced

967

?mm Hollow walls of two half brick skins including wire ties



Not Priced

968

?mm Hollow walls of two half brick skins including wire ties, circular on plan



Not Priced

969

?mm Solid walls



Not Priced

970

One and a half brick walls



Not Priced

971

One and a half brick walls circular on plan



Not Priced

972

?mm Hollow walls of one half brick and one one brick skins including wire ties



Not Priced

?mm Hollow walls of one half brick and one one brick skins including wire ties, circular on plan



Not Priced

974

Two brick walls



Not Priced

975

Two brick walls circular on plan



Not Priced

976

Half brick kerbs ?mm high

m

Not Priced

977

Half brick kerbs ?mm high, circular on plan

m

Not Priced

978

One brick kerbs ?mm high

m

Not Priced

979

One brick kerbs ?mm high, circular on plan

m

Not Priced

980

User note

981

Attention is drawn to the fact that separate items for brickwork in lintels are to be given only when the type of brick and/or mortar mix differs from that of the adjoining brickwork

982

Brickwork of ? bricks in class ? mortar in lintels

983

Half brick walls



Not Priced

984

One brick walls



Not Priced

973

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-107-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

985

?mm Solid walls



Not Priced

986

One and a half brick walls



Not Priced

987

Two brick walls



Not Priced

988

BRICKWORK SUNDRIES

989

Cutting toothings and bonding new brickwork to existing



Not Priced

990

Extra over for building brickwork to battered face with each course set back ?mm



Not Priced

Extra over for building brickwork to battered face with sloping bed joints



Not Priced

Extra over for building brickwork to oversailing face with each course projecting ?mm



Not Priced

991

992

993

Splayed mortar fillets one course high in ?mm cavities

m

Not Priced

994

Splayed mortar fillets two courses high in ?mm cavities

m

Not Priced

995

Closing ?mm cavities of hollow walls vertically with brickwork half brick wide

m

Not Priced

Closing ?mm cavities of hollow walls vertically with brickwork one brick wide

m

Not Priced

Closing ?mm cavities of hollow walls horizontally with one course of brickwork

m

Not Priced

Closing ?mm cavities of hollow walls horizontally with two courses of brickwork

m

Not Priced

Closing ?mm cavities at raking tops of hollow walls with two courses of brickwork

m

Not Priced

? x ?mm Horizontal flues in brickwork including rendering smooth in mortar

m

Not Priced

? x ?mm Vertical flues in brickwork including rendering smooth in mortar

m

Not Priced

? x ?mm Raking flues in brickwork including rendering smooth in mortar

m

Not Priced

996

997

998

999

1000

1001

1002

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-108-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1003

1004

1005

1006

R

Not Priced

Extra over for rough segmental arch in half (one etc?) brick wall, ?mm span and ?mm high, of one (two etc?) brick-on-edge header ring(s), including support centre

No

Not Priced

Extra over for ?mm diameter rough semi-circular arch in half (one etc?) brick wall, of one (two etc ?) brick-on-edge header ring(s), including support centre

No

Not Priced

Extra over for ?mm diameter rough bullseye arch in half (one etc?) brick wall, of one (two etc ?) brick-on-edge header ring(s), including support centre

No

Not Priced

Extra over for ?mm diameter ?mm deep rough semi-circular niche in brickwork, including support centre

No

Not Priced

1007

Fair face to brickwork of (unstriated?) selected building bricks in horizontal stretcher bond pointed with flush horizontal and vertical joints

1008

Fair face to brickwork of (unstriated?) selected building bricks in horizontal stretcher bond, pointed with recessed horizontal and flush vertical joints

1009

Fair face to brickwork of (unstriated?) selected building bricks in horizontal stretcher bond, pointed with recessed horizontal and vertical joints

1010

Extra over for fair face



Not Priced

1011

Half brick walls pointed on both sides



Not Priced

1012

Bagging of 1:3 cement and sand mixture

1013

Cement wash of 1:3 liquid cement and sand mixture applied with a brush

1014

On brick walls, piers, etc



Not Priced

1015

On concrete walls, columns, etc including removing ridges, irregularities, etc



Not Priced

On concrete ceilings, beams, etc including removing ridges, irregularities, etc



Not Priced

1016

1017

Joint forming material in movement joints

1018

?mm Fibre board built in vertically between brick skins



Not Priced

1019

?mm Fibre board built in vertically through brick walls



Not Priced

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-109-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1020

1021

1022

1023

R

Not Priced

?mm Bitumen impregnated fibre board built in vertically between brick skins



Not Priced

?mm Bitumen impregnated fibre board built in vertically through brick walls



Not Priced

?mm Expanded polystyrene (density 33kg per m3) built in vertically between brick skins



Not Priced

?mm Expanded polystyrene (density 33kg per m3) ?mm wide with one tear-off strip, built in vertically through brick walls

m

Not Priced

1024

Steel bar reinforcement

1025

?mm Diameter mild steel bars built in horizontally

t

Not Priced

1026

?mm Diameter high tensile steel bars built in horizontally

t

Not Priced

1027

2,5mm Brickwork reinforcement

1028

2,5mm Galvanised brick reinforcement

1029

?mm Wide reinforcement built in horizontally

m

Not Priced

1030

?mm Wide reinforcement built in horizontally, circular on plan

m

Not Priced

1031

Prestressed fabricated concrete lintels including necessary temporary supports

1032

? x ?mm Lintels in lengths not exceeding 3m

m

Not Priced

1033

? x ?mm Lintels in lengths exceeding 3m and not exceeding 4,5m

m

Not Priced

? x ?mm Lintels in lengths exceeding 4,5m and not exceeding 6m

m

Not Priced

m

Not Priced

No

Not Priced

1034

1035

Turning pieces to lintels etc

1036

?mm Wide turning pieces

1037

Galvanised wire ties etc

1038

4mm Diameter roof tie 2m girth bent double, with one end built into brickwork and other end fixed to timber

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-110-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1039

4mm Diameter roof tie 2m girth bent double, with one end cast into concrete and other end fixed to timber

Not Priced

m

Not Priced

30 x 1,6mm Cramp 500mm long with one end fixed to timber and other end built into brickwork

No

Not Priced

30 x 1,6mm Wall tie 500mm long with one end cast into concrete and other end built into brickwork

No

Not Priced

30 x 1,6mm Wall tie 500mm long with one end shot pinned to concrete and other end built into brickwork

No

Not Priced

30 x 1,6mm Roof tie 1,5m long with one end built into brickwork and other end fixed to timber

No

Not Priced

30 x 1,6mm Roof tie 1,5m long with one end cast into concrete and other end fixed to timber

No

Not Priced

30 x 1,6mm Ceiling hanger 1m long with one end shot pinned to concrete and other end fixed to timber

No

Not Priced

Galvanised hoop iron cramps, ties, etc

1041

40 x 1,6mm "?" wall tie strips shot pinned to concrete and with ties bent out and built into brickwork

1043

1044

1045

1046

1047

Not Priced

No

1040

1042

R

1048

Air bricks etc

1049

229 x 76mm Clay vermin proof air brick

No

Not Priced

1050

229 x 152mm Clay vermin proof air brick

No

Not Priced

1051

Set of ? ? x ?mm clay vermin proof air bricks

No

Not Priced

1052

233 x 175mm Foam plastic air vent

No

Not Priced

1053

262 x 185mm Fibrous plaster air vent

No

Not Priced

1054

FACE BRICKWORK

1055

"?" face bricks pointed with flush horizontal and vertical joints

1056

"?" face bricks pointed with recessed horizontal and flush vertical joints

1057

"?" face bricks pointed with recessed horizontal and vertical joints

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-111-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1058

User Note

1059

Where the radius of circular work is less than 1m the use of header courses, cut bricks or specially made bricks is to be ascertained and described as such

1060

Extra over brickwork for face brickwork in foundations (Provisional)



Not Priced

1061

Extra over brickwork for face brickwork



Not Priced

1062

User Note

1063

The following item is only applicable where special (more expensive) building bricks are specified for the rough brickwork in the first instance

1064

Extra over brickwork in NFX (NFPE, NFXE, etc?) bricks for face brickwork



Not Priced

Extra over brickwork for face brickwork, circular on plan to exceeding 2m radius.



Not Priced

Extra over brickwork for face brickwork, circular on plan to not exceeding 2m radius



Not Priced

Extra over brickwork for face brickwork in header courses, circular on plan to not exceeding 2m radius



Not Priced

1068

Extra over brickwork for face brickwork in soldier courses



Not Priced

1069

Extra over brickwork for face brickwork in soldier courses, circular on plan to exceeding 2m radius



Not Priced

Extra over brickwork for face brickwork in soldier courses, circular on plan to not exceeding 2m radius



Not Priced

1071

?mm Cut linings to concrete



Not Priced

1072

?mm Cut linings to concrete, circular on plan to exceeding 2m radius



Not Priced

? mm Cut linings to concrete, circular on plan to not exceeding 2m radius



Not Priced

1074

Half brick walls pointed on both sides



Not Priced

1075

One brick walls in English bond pointed on both sides



Not Priced

1065

1066

1067

1070

1073

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-112-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1076

R

Not Priced

Extra over brickwork for brick-on-flat header course bands ? course(s) high

m

Not Priced

Extra over brickwork for brick-on-edge header course bands ? course(s) high

m

Not Priced

Extra over brickwork for brick-on-end soldier course bands ? course(s) high

m

Not Priced

Extra over brickwork for brick-on-edge header course lintels ? course(s) high, pointed on face and ?mm soffit

m

Not Priced

Extra over brickwork for brick-on-end soldier course lintels ? course(s) high, pointed on face and ?mm soffit

m

Not Priced

Extra over brickwork for horizontal corbelled band ? courses high and ?mm projection overall, pointed on face and soffits

m

Not Priced

1082

Fair raking cutting

m

Not Priced

1083

Fair splay cutting

m

Not Priced

1084

Fair stepped cutting and fitting over treads and risers

m

Not Priced

1085

Fair circular cutting

m

Not Priced

1086

Fair cutting at squint quoins or birdsmouth angles

m

Not Priced

1087

Cutting toothings and bonding new face brickwork to existing

m

Not Priced

Fair cutting and fitting around pipe not exceeding 100mm diameter

No

Not Priced

Fair cutting and fitting around pipe exceeding ?mm and not exceeding ?mm diameter

No

Not Priced

1077

1078

1079

1080

1081

1088

1089

1090

Brick-on-edge header course copings, sills, etc of "?" face bricks, pointed with flush (recessed?) joints on all exposed faces

1091

110mm Copings on top of half brick walls

m

Not Priced

1092

220mm Copings on top of one brick walls

m

Not Priced

1093

330mm Copings on top of one-and-a-half brick walls

m

Not Priced

1094

?mm Copings on raking tops of ? brick walls

m

Not Priced

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-113-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1095

R

Not Priced

?mm Copings on tops of ? brick walls, circular on plan to exceeding 2m radius

m

Not Priced

?mm Copings to tops of ? brick walls, circular on plan to not exceeding 2m radius

m

Not Priced

1097

?mm Wide sills set level and slightly projecting

m

Not Priced

1098

?mm Wide sills set sloping and slightly projecting

m

Not Priced

Extra over brickwork for segmental arch in half (one etc?) brick wall, ?mm span and ?mm high, of one (two etc ?) brick-on-edge header course ring(s), pointed on soffit and one side (both sides?), including support centre

No

Not Priced

Extra over brickwork for ?mm diameter semi-circular arch in one brick wall, of one (two etc?) brick-on-edge header course ring(s), pointed on soffit and one side (both sides?), including support centre

No

Not Priced

Extra over brickwork for ?mm diameter bullseye arch in one brick wall, of one (two etc?) brick-on-edge header course ring(s), pointed in opening and one side (both sides?), including support centre

No

Not Priced

Extra over brickwork for semi-circular niche ?mm diameter and ?mm deep, with one brick-on-edge header course ring and brick-on-edge header course sill, pointed on exposed faces, including support centre

No

Not Priced



Not Priced

1096

Fair arches, recesses, etc of "?" face bricks, pointed with flush (recessed?) joints Fair arches, recesses, etc of "?" face bricks, pointed with recessed joints 1101

1102

1103

1104

1105

BLOCKWORK

1106

FOUNDATIONS (PROVISIONAL)

1107

SUPERSTRUCTURE

1108

Blockwork in class ? mortar

1109

Blockwork in class ? mortar with cores filled solid with mortar

1110

?mm Walls

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-114-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1111

?mm Walls circular on plan



Not Priced

1112

?mm Walls against waterproofing



Not Priced

1113

?mm Walls in beamfilling



Not Priced

1114

?mm Linings against concrete



Not Priced

1115

?mm Linings ?mm away from concrete



Not Priced

1116

?mm Walls with blocks threaded over vertical reinforcement



Not Priced

1117

?mm Hollow walls of two ?mm skins including wall ties



Not Priced

1118

?mm Hollow walls of one ?mm and one ?mm skins including wall ties



Not Priced

Extra over ?mm hollow walls of two ?mm skins for internal stiffener piers ?mm wide

m

Not Priced

1120

?mm Lintels one course high of ? x ? x ?mm U-blocks

m

Not Priced

1121

?mm Lintels one course high of ? x ? x ?mm U-blocks filled solid with 20MPa/10mm concrete (reinforcement elsewhere) m

Not Priced



Not Priced



Not Priced

No

Not Priced

1119

1122

BLOCKWORK SUNDRIES

1123

Fair face to blockwork pointed with flush (recessed?) horizontal and vertical joints

1124

Fair face to blockwork pointed with recessed horizontal and vertical joints

1125

Extra over for fair face

1126

Bagging of 1:3 cement and sand mixture

1127

Cement wash of 1:3 liquid cement and sand mixture applied with a brush

1128

On block walls

1129

Mortar filling including necessary formwork to soffits

1130

To single hollow core of ?mm hollow block

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-115-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1131

Wall bonding ties

1132

6mm Diameter galvanised mild steel rod wall bonding tie ?mm girth, four times bent and built horizontally into blockwork at wall intersections, construction joints, etc

No

Not Priced

70mm Wide "?" galvanised expanded steel wall bonding tie ?mm long built horizontally into blockwork at wall intersections, construction joints, etc

No

Not Priced

1133

1134

FACE BLOCKWORK

1135

? x ? x ?mm "?" face blocks in class ? mortar, pointed with flush (recessed?) horizontal and vertical joints

1136

Extra over ?mm skin of blockwork for face blockwork



Not Priced

1137

?mm Block walls pointed on both sides



Not Priced

1138

?mm Block walls pointed on both sides, circular on plan to exceeding 2m radius



Not Priced

?mm Block walls pointed on both sides, circular on plan to not exceeding 2m radius



Not Priced

1140

?mm Cut block linings to concrete



Not Priced

1141

?mm Lintels one course high of ? x ? x ?mm U-blocks pointed on soffit and one side (both sides?)

m

Not Priced

?mm Lintels one course high of ? x ? x ?mm U-blocks filled solid with 20MPa/10mm concrete, pointed on soffit and one side (both sides?) (reinforcement elsewhere)

m

Not Priced

?mm Copings one course high of ? x ? x ?mm inverted U-blocks, pointed on top and both sides

m

Not Priced

?mm Sills of ? x ? x ?mm splayed sill blocks, pointed on top and one side

m

Not Priced

1145

? x ?mm Piers of ? x ? x ?mm blocks pointed all round

m

Not Priced

1146

Capping to ? x ?mm pier of ? x ? x ?mm splayed blocks, pointed on top and sides

No

Not Priced

1139

1142

1143

1144

1147

QUARRY TILES

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-116-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1148

? x ? x ?mm Type ? quarry tiles on concrete with continuous joints in both directions and pointed on all exposed surfaces

1149

? x ? x ?mm Type ? quarry tiles on brickwork with continuous joints in both directions and pointed on all exposed surfaces

1150

User Note

1151

Where tiles to sills etc are to be cut to suit widths, it is to be stated in the descriptions

1152

?mm Wide sills of ? row(s) of tiles set flat and slightly projecting

m

Not Priced

?mm Wide sills of ? row(s) of tiles set sloping and slightly projecting

m

Not Priced

?mm Wide bullnosed edge sills of ? row(s) of tiles set flat and slightly projecting

m

Not Priced

?mm Wide bullnosed edge sills of ? row(s) of tiles set sloping and slightly projecting

m

Not Priced

?mm Wide copings of ? row(s) of tiles set flat and slightly projecting

m

Not Priced

?mm Wide copings of ? row(s) of tiles set sloping and slightly projecting

m

Not Priced

?mm Wide saddleback copings of two rows of tiles set sloping and slightly projecting

m

Not Priced

1153

1154

1155

1156

1157

1158

1159

FIBRE-CEMENT WINDOW SILLS

1160

Natural grey (Slate grey?) sills in single lengths bedded in class ? mortar including metal fixing lugs etc

1161

? x ?mm Wide sills set flat and slightly projecting

m

Not Priced

1162

? x ?mm Wide sills set sloping and slightly projecting

m

Not Priced

1163

DECORATIVE SCREEN WALLS AND GRILLES

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-117-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1164

Screen walls of type ? grille blocks bedded and jointed in class ? mortar, with continuous joints in both directions and pointed with flush (recessed?) horizontal and vertical joints

1165

?mm Walls pointed on both sides



Not Priced

1166

?mm Walls pointed on both sides and in openings



Not Priced

1167

GLASS BLOCK WALLS

1168

? x ? x ?mm Type ? glass blocks bedded and jointed in slow-setting class ? mortar with continuous joints in both directions and pointed in tinted mortar on both sides with flush (recessed?) horizontal and vertical joints

1169

?mm Walls



Not Priced

1170

?mm Walls circular on plan



Not Priced

1171

Sundries

1172

?mm Wide horizontal slip joints below glass blocks of two layers type FV dampproofing

m

Not Priced

? x ?mm Wide expanded polystyrene (density 33kg per m3) horizontally and vertically between glass blocks and structure

m

Not Priced

t

Not Priced

1173

1174

8mm Diameter galvanised mild steel bar reinforcement horizontally and vertically

1175

PAVING

1176

SUPPLEMENTARY PREAMBLES

1177

Quarry tiles, cement, terrazzo and similar tiles, precast concrete bricks, blocks, etc

1178

Tiles shall be of approved manufacture, well burnt or cured, and uniform and true in size, shape and colour

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-118-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1179

Preparation of concrete floor beds, slabs, etc for pavings

1180

Concrete surfaces shall be hacked (preferably by mechanical means) until all laitance, dirt, oil, etc is dislodged and swept clean of all loose matter. Surfaces shall then be wetted and kept damp for at least six hours before slushing with 1:2 cement/sand and while still wet, pavings, etc shall be laid on a 1:4 cement mortar bed not exceeding 25mm thick and jointed and pointed with hollowed joints. Sand shall be clean, sharp river sand

1181

Paving of "?" paving bricks with butt joints on ?mm thick river sand bed with sand-and-cement mixture swept into joints and hosed down, including preparation of ground or filling

1182

Paving of ? x ? x ?mm thick precast concrete paving blocks with butt joints on ?mm thick river sand bed with sand-and-cement mixture swept into joints and hosed down, including preparation of ground or filling

1183

Paving in stretcher bond



Not Priced

1184

Paving in stretcher bond to falls



Not Priced

1185

Paving in ? bond



Not Priced

1186

Paving in ? bond to falls



Not Priced

1187

Fair circular cutting

m

Not Priced

1188

220mm Wide brick-on-flat header course edgings on ?mm thick mortar bed, including necessary excavation

m

Not Priced

220mm Wide brick-on-flat header course edgings on ?mm thick mortar bed including necessary excavation, circular on plan with tapered radiating joints

m

Not Priced

220mm Wide brick-on-edge header course edgings on ?mm thick mortar bed, including necessary excavation

m

Not Priced

220mm Wide brick-on-edge header course edgings on ?mm thick mortar bed including necessary excavation, circular on plan with tapered radiating joints

m

Not Priced

110mm Wide brick-on-end edgings on ?mm thick mortar bed, including necessary excavation

m

Not Priced

1189

1190

1191

1192

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-119-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1193

200mm Wide block-on-flat header course edgings on ?mm thick mortar bed, including necessary excavation

R

Not Priced

m

Not Priced

1194

Paving of double zig-zag (shape S-A) interlocking precast concrete paving blocks complying with SANS 1058, with butt joints on ?mm thick river sand bed with sand swept into joints, including preparation of ground or filling

1195

Paving of type ? interlocking precast concrete paving blocks with butt joints on ?mm thick river sand bed with sand swept into joints, including preparation of ground or filling

1196

Paving of ?mm thick blocks including edge blocks



Not Priced

1197

Paving of ?mm thick blocks including edge blocks, to falls



Not Priced

1198

Extra over for contrasting colour blocks as marker lines

m

Not Priced

1199

Fair circular cutting

m

Not Priced

1200

Paving of ? x ? x ?mm precast concrete grey (charcoal etc?) paving slabs laid on ?mm thick river sand bed, including preparation of ground or filling

1201

Paving of ? x ? x ?mm precast concrete (colour?) paving slabs with brushed finish, laid on ?mm thick river sand bed, including preparation of ground or filling

1202

Paving of slabs laid with butt joints with sand swept into joints



Not Priced

Paving of slabs laid with butt joints with sand swept into joints, to falls



Not Priced

Paving of slabs laid with ?mm wide joints, jointed with mortar and flush pointed



Not Priced

Paving of slabs laid with ?mm wide joints, jointed with mortar and flush pointed, to falls



Not Priced

m

Not Priced

1203

1204

1205

1206

Fair circular cutting

1207

Paving of ? x ? x ?mm precast concrete grey (charcoal etc?) paving slabs, on concrete

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-120-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1208

Paving of ? x ? x ?mm precast concrete (colour?) paving slabs with brushed finish, on concrete

1209

Paving of slabs laid with ?mm wide joints on ?mm thick mortar bed, jointed with mortar and pointed with hollowed joints



Not Priced

Paving of slabs laid loose with open joints on polythene bags filled with stabilised sand/cement mixture under corners and centres of slabs, on waterproofing to roofs etc



Not Priced

m

Not Priced

1210

1211

Fair circular cutting

1212

Paving of "?" paving bricks on concrete, bedded and jointed in cement mortar and pointed with hollowed joints

1213

Paving in stretcher bond on 25mm thick mortar bed



Not Priced

1214

Paving in ? bond on ?mm thick mortar bed



Not Priced

1215

Paving in ? bond on average ?mm thick mortar bed to falls



Not Priced

1216

Fair circular cutting

m

Not Priced

1217

Fair cutting and fitting around pipe not exceeding 100mm diameter

No

Not Priced

220mm Wide brick-on-flat header course edgings on ?mm thick mortar bed

m

Not Priced

220mm Wide brick-on-flat header course edgings on ?mm thick mortar bed, circular on plan with tapered radiating joints

m

Not Priced

220mm Wide brick-on-edge header course edgings on ?mm thick mortar bed

m

Not Priced

220mm Wide brick-on-edge header course edgings on ?mm thick mortar bed, circular on plan with tapered radiating joints

m

Not Priced

?mm High brick-on-flat header course risers on ?mm thick mortar bed

m

Not Priced

?mm Wide brick-on-flat header course treads on ?mm thick mortar bed

m

Not Priced

?mm Wide brick-on-edge header course treads of one full and one cut course on ?mm thick mortar bed

m

Not Priced

1218

1219

1220

1221

1222

1223

1224

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-121-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1225

Paving of ? x ? x ?mm type ? quarry tiles on concrete with continuous joints in both directions, flush pointed on all exposed surfaces

1226

Paving of ? x ? x ?mm type ? quarry tiles on concrete in stretcher bond pattern, flush pointed on all exposed surfaces

1227

Paving on ?mm thick mortar bed



Not Priced

1228

Paving on average ?mm thick mortar bed to falls



Not Priced

1229

Extra over for ?mm wide bands, margins, etc in contrasting colour

m

Not Priced

1230

Fair circular cutting

m

Not Priced

1231

?mm Wide treads on ?mm thick mortar bed

m

Not Priced

1232

?mm Wide treads with bullnosed edge, on ?mm thick mortar bed

m

Not Priced

1233

?mm High risers on ?mm thick mortar bed

m

Not Priced

1234

RUBBLE WALLS

1235

Rubble walls of uncoursed random local stone to the principal agent's approval

1236

Mass and irregular walls (facing and pointing elsewhere)



Not Priced

1237

Rubble walls of uncoursed random local stone to the principal agent's approval, including facing and pointing on one side (both sides?)

1238

?mm Walls



Not Priced

1239

?mm Walls circular on plan



Not Priced

1240

?mm Walls in beamfilling



Not Priced

1241

Average ?mm thick walls battered on one face



Not Priced

1242

?mm Linings to brickwork including wire ties



Not Priced

1243

?mm Linings to concrete including wire ties



Not Priced

1244

? x ?mm Copings

m

Not Priced

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-122-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1245

? x ?mm Sloping sills

1246

Extra over for rectangular recess ? x ? x ?mm deep, pointed on exposed faces, including turning piece

R

Not Priced

m

Not Priced

No

Not Priced

1247

Facing and pointing

1248

To mass and irregular work



Not Priced

1249

To tops, ends and reveals of walls



Not Priced

1250

Sundries

1251

Trimming face of rubble walls to receive in-situ finishes etc



Not Priced

1252

Angles pitched from one face

m

Not Priced

1253

Angles pitched from both faces

m

Not Priced

1254

? x ?mm Vertical flue in rubble walls including rendering smooth in mortar

m

Not Priced

1255

?mm Wide turning pieces to lintels etc

m

Not Priced

1256

?mm Wide centre to segmental arch ?mm span x ?mm high above springing line

No

Not Priced

1257

STONEWORK

1258

SUPPLEMENTARY PREAMBLES

1259

Slate, marble, granite, etc

1260

Slate, marble, granite, etc is to be best quality from an approved quarry free from cracks and other defects and equal to samples to be submitted to and approved by the principal agent. Each stone is to hold its full size, square to the back and to be set on its natural quarry bed where applicable

1261

Setting out

1262

Care shall be exercised in setting out the work, the preparation of templates and the checking of the detail drawings. All measurements shall be taken on the site where necessary and the full size setting out shall be done at the yard so as to ensure the proper fitting of each stone

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-123-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1263

Before putting any work in hand the contractor is to submit to the principal agent for his approval, details of the manner in which he proposes to set out the slabs and joints in all wall facings, pavings, margins, skirtings, sills, treads, risers, etc together with samples of grain or pattern matching. Joints in margins, skirtings, sills, treads, risers, etc are to be kept to a minimum

1264

Face labours

1265

Face labours are to match samples to be submitted to and approved by the principal agent

1266

Arrises are to be clean and sharp except to treads and thresholds where they are to be slightly rounded

1267

Unless otherwise described all exposed edges, projections, etc shall be finished to match the face finish

1268

Bedding and jointing

1269

Slate, marble, granite and other floor pavings are to be bedded solidly on and including mortar beddings and are to have tightly fitting butt joints unless otherwise stated

1270

Where stonework is to be fixed with adhesive to screeded or plastered surfaces, the adhesive is to be suitable for and compatible with the type of stone. The contractor will be liable for any defects to stonework caused by the adhesive. The screeds and plaster will be executed by others and will be given separately

R

Not Priced

R

Not Priced

Where wall linings are to be mechanically fixed, phosfor bronze rods, expanding bolts, etc are to be used with solid cement mortar bedding. The fixing system shall be concealed and shall be submitted to the principal agent for approval before the work commences. Such approval will not release the contractor from his responsibility for the work 1271

Where soffit linings are suspended the suspension system shall be concealed and shall be submitted to the principal agent for approval before work commences

1272

Where tolerance screws are required these are to be stainless steel expanding bolt type with matching stainless steel brackets and PVC clad dowels with nuts, washers, etc

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-124-

24/02/2006 10:50:51 AM

Brought forward 1273

Damaged work

1274

Damaged stonework shall be discarded and replaced at the contractor's expense. No touching up will be permitted except in exceptional cases with the principal agent's consent

1275

Descriptions

1276

Descriptions of stonework shall be deemed to include preparatory work, labours to backs, beds and joints, templates, mortices for bolts etc and for hoisting and setting in position, bedding, jointing and pointing, casing and protecting from injury and cleaning down at completion and sealing of marble surfaces with two coats ? sealant

1277

Descriptions of recessed pointing to stonework shall be deemed to include square recessed, hollow recessed, weathered pointing, etc

1278

Drawings

1279

Reference is to be made to the drawings annexed to (issued separately with?) these bills of quantities

1280

User note

1281

Slate slabs vary in thickness from approximately 15mm to 25mm

R

Not Priced

R

Not Priced

Marble and granite slabs for floor and wall finishes are generally 20mm thick Marble and granite slabs for worktops are also available in 32mm thickness if required 1282

SLATE PAVING

1283

MARBLE PAVING

1284

GRANITE PAVING

1285

? slate paving with polished finish, bedded in cement mortar (fixed with adhesive (screed by others)?)

1286

? marble paving with honed non-slip finish, bedded in cement mortar (fixed with adhesive (screed by others)?)

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-125-

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1287

? marble paving with polished finish, bedded in cement mortar (fixed with adhesive (screed by others)?)

1288

? granite paving with flamed non-slip finish, bedded in cement mortar (fixed with adhesive (screed by others)?)

1289

? granite paving with polished finish, bedded in cement mortar (fixed with adhesive (screed by others)?)

1290

Paving to floors of ?mm thick slabs not exceeding 0,5m² on face



Not Priced

Paving to floors of ?mm thick slabs exceeding 0,5m² and not exceeding 1m² on face



Not Priced

Paving to floors to falls of ?mm thick slabs not exceeding 0,5m² on face with bedding average ?mm thick



Not Priced

1291

1292

1293

Fair circular cutting

m

Not Priced

1294

Polished fair edges to ?mm thick paving

m

Not Priced

1295

Polished fair edges to ?mm thick paving, circular on plan to ?m radius

m

Not Priced

1296

? x ?mm Margins

m

Not Priced

1297

? x ?mm Skirtings with polished top edge

m

Not Priced

1298

Extra over for mitred internal angle

No

Not Priced

1299

Extra over for mitred external angle

No

Not Priced

1300

? x ?mm Skirtings with moulded and polished top edge (refer to drawing No ?, detail ?)

m

Not Priced

1301

Extra over for mitred internal angle

No

Not Priced

1302

Extra over for mitred external angle

No

Not Priced

1303

? x ?mm Sills with bullnosed and polished front edge

m

Not Priced

1304

? x ?mm Risers

m

Not Priced

1305

? x ?mm Risers in facets, circular on plan to ?mm radius

m

Not Priced

1306

? x ?mm Treads with chamfered and polished front edge

m

Not Priced

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-126-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1307

1308

R

Not Priced

? x ?mm Treads with chamfered and polished front edge, circular on plan to average ?mm radius with radiating joints

m

Not Priced

? x ?mm Treads with set of five reedings in top and with bullnosed and polished front edge

m

Not Priced

1309

? x ?mm Notch in ?mm thick paving

No

Not Priced

1310

Hole for pipe not exceeding ?mm diameter through ?mm thick paving

No

Not Priced

Hole for pipe exceeding ?mm and not exceeding ?mm diameter through ?mm thick paving

No

Not Priced

1311

1312

SLATE WALL LININGS ETC

1313

MARBLE WALL LININGS ETC

1314

GRANITE WALL LININGS ETC

1315

? slate wall linings with polished finish, fixed with adhesive (plaster by others) (mechanically fixed including mortar backing?)

1316

? marble wall linings with polished finish, fixed with adhesive (plaster by others) (mechanically fixed including mortar backing?)

1317

? granite wall linings with polished finish, fixed with adhesive (plaster by others) (mechanically fixed including mortar backing?)

1318

Lining to walls of ?mm thick slabs not exceeding 0,5m² on face



Not Priced

Lining to walls of ?mm thick slabs exceeding 0,5m² and not exceeding 1m² on face



Not Priced

Lining to sides and soffits of beams in slabs not exceeding 0,5m² on face



Not Priced

1319

1320

1321

Fair circular cutting

m

Not Priced

1322

Polished fair edges to ?mm thick linings

m

Not Priced

1323

Polished fair edges to ?mm thick linings, circular on plan to ?m radius

m

Not Priced

Polished bullnosed edges to ?mm thick linings

m

Not Priced

1324

Carried forward Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-127-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1325

? x ?mm Rebates

m

Not Priced

1326

? x ?mm Stopped rebates

m

Not Priced

1327

?mm Radius polished rounded angles

m

Not Priced

1328

?mm Radius sunk and polished rounded angles

m

Not Priced

1329

?mm Radius polished throats

m

Not Priced

1330

Polished birdsmouth external angles

m

Not Priced

1331

? x ?mm Notch in ?mm thick lining

No

Not Priced

1332

Hole for pipe not exceeding ?mm diameter through ?mm thick lining

No

Not Priced

Hole for pipe exceeding ?mm and not exceeding ?mm diameter through ?mm thick lining

No

Not Priced

? x ? x ?mm High extreme keystone to flat arch with sides tapering to ?mm wide at bottom, polished on face and soffit

No

Not Priced

m

Not Priced

1333

1334

1335

? granite with polished finish

1336

? x ?mm Saddleback copings with drip groove in soffit on both sides, bedded on top of half (one?) brick wall

1337

Extra over for returned stopped end

No

Not Priced

1338

Extra over for mitred angle

No

Not Priced

1339

? x ?mm Profiled cornices. (Refer to drawing No ?, detail ?)

m

Not Priced

1340

Extra over for mitred angle

No

Not Priced

1341

? x ?mm Rebated door frames in suitable butt jointed lengths bedded against and bolted to brickwork or concrete with and including expansion bolts with heads of bolts sunk and concealed

m

Not Priced

1342

Extra over for mitred joint between top and sides

No

Not Priced

1343

35 x 100 x 3mm Deep sinking for hinge plate

No

Not Priced

1344

35 x 100 x 10mm Deep overall shaped sinking for striking plate

No

Not Priced

Carried to summary Bill No 8 Masonry ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-128-

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

Quantity

Rate

Amount

1345

BILL NO ?

1346

WATERPROOFING

1347

SUPPLEMENTARY PREAMBLES

1348

Waterproofing

1349

Waterproofing of roofs, basements, etc shall be laid under a ten year guarantee. Waterproofing to roofs shall be laid to even falls to outlets etc with necessary ridges, hips and valleys. Descriptions of sheet or membrane waterproofing shall be deemed to include additional labour to turn-ups and turn-downs

1350

DAMPPROOFING OF WALLS AND FLOORS

1351

One layer type FV dampproof course

1352

One layer 375 micron embossed polyethylene dampproof course (SANS 952-1985 type B)

1353

In walls



Not Priced

1354

In walls vertically at reveals



Not Priced

1355

One layer 250 micron green polyethylene waterproof sheeting (SANS 952-1985 type C) sealed at laps with PVC self-adhesive tape

1356

One layer 375 (500, 1000?) micron orange polyethylene waterproof sheeting (SANS 952-1985 type A) sealed at laps with PVC self-adhesive tape

1357

Under surface beds



Not Priced

1358

Vertically between walls



Not Priced

1359

Two coats "?" bitumen emulsion waterproof coating

1360

Primer and two coats "?" heavy duty bitumen emulsion waterproof coating

1361

On concrete floors



Not Priced

1362

On concrete walls and columns in foundations (Provisional)



Not Priced

1363

On concrete walls, columns and beams



Not Priced

1364

On fair faced brick walls



Not Priced

Carried forward Bill No 9 Waterproofing ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-129-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1365

On bagged brick walls

1366

WATERPROOFING TO ROOFS, BASEMENTS, ETC

1367

Five coat "?" fibre reinforced heavy duty maintenance free acrylic waterproofing

1368

One layer 4mm special polyester fully bonded waterproof membrane comprising a matrix modified with polypropylene dual reinforced with non-woven polyester cloth and glass fibre tissue, laid with 75mm side and 100mm end laps

1369

One layer 1,7mm self-adhesive fully bonded waterproof membrane comprising 1,4mm rubberised asphalt and a layer of heat-resistant woven polypropylene mesh, laid with 75mm side and 100mm end laps

1370

Prime with one coat bitumen primer and one layer 4mm fully bonded waterproof membrane comprising two bitumen layers reinforced with woven spunbonded polyester fabric and coated with polyethelene film for heat bonding, laid with 100mm side and 150mm end laps

1371

Cementitious waterproofing system (suitable for tiling) comprising primer coat plasticised modified acrylic (PMA) (consisting of 5l PMA, 5 litres water and 16,5kg cement (32,5N), one layer pre-cut polypropylene fabric fully saturated in PMA slurry and two full coats PMA slurry

1372

Cementitious waterproofing system (suitable for tiling) comprising patching defects with polymer modified flexible (PMF) waterproofing slurry and three full coats PMF waterproofing slurry applied with a brush to a final dry film thickness of 2 to 3mm

1373

R

Not Priced



Not Priced

On floors



Not Priced

1374

On balcony floors



Not Priced

1375

On shower floors



Not Priced

1376

On flat roofs



Not Priced

1377

On sloping roofs with ? degrees pitch



Not Priced

1378

On walls



Not Priced

1379

On turn-ups and turn-downs exceeding 300mm girth



Not Priced

Carried forward Bill No 9 Waterproofing ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-130-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1380

On tops and sides of inverted beams



Not Priced

1381

On bottoms and sides of floor ducts, channels, etc



Not Priced

1382

On bottoms and sides of box gutters



Not Priced

1383

On bottoms and sides of plant boxes



Not Priced

1384

On internal surfaces of ? x ? x ?mm deep sump, catchpit, etc

No

Not Priced

1385

Sealing edges to brickwork or concrete

m

Not Priced

1386

Sealing edges to brickwork or concrete including trowelled mastic bead

m

Not Priced

Bandage cover flashing strips ?mm girth at turn-ups, including sealing top edge with mastic in and including groove in brickwork

m

Not Priced

Additional membrane ?mm girth at internal and external angles

m

Not Priced

Additional membrane ?mm girth at internal and external angles, circular on plan including forming darts as necessary

m

Not Priced

1387

1388

1389

1390

Additional membrane and sealing into ?mm diameter outlet

No

Not Priced

1391

Collar and sealing around pipe not exceeding 100mm internal diameter

No

Not Priced

1392

Two layers "?" mastic asphalt waterproofing

1393

Two layers "?" mastic asphalt trafficable waterproofing with coarse building sand or fine stone chips evenly spread and well rolled in

1394

?mm Thick on flat roofs including "?" grade ? paper underlayer with 30mm laps



Not Priced

1395

?mm Thick on sloping roofs with ? degrees pitch.



Not Priced

1396

?mm Thick on walls



Not Priced

1397

?mm Thick on walls circular on plan to exceeding 300mm radius



Not Priced

Carried forward Bill No 9 Waterproofing ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-131-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1398

R

Not Priced

?mm Thick on walls circular on plan to not exceeding 300mm radius



Not Priced

1399

?mm Thick on tops and sides of inverted beams



Not Priced

1400

?mm Thick on bottoms and sides of floor ducts, channels, etc



Not Priced

1401

?mm Thick on bottoms and sides of box gutters



Not Priced

1402

?mm Thick on internal surfaces of ? x ? x ?mm deep sump, catchpit, etc

No

Not Priced

?mm Skirtings average ?mm high with ? x ?mm triangular fillet at bottom

m

Not Priced

?mm Skirtings average ?mm high with ? x ?mm triangular fillet at bottom, circular on plan to exceeding 300mm radius

m

Not Priced

?mm Skirtings average ?mm high with ? x ?mm triangular fillet at bottom, circular on plan to not exceeding 300mm radius

m

Not Priced

?mm Skirtings average ?mm high with top turned into and including groove in brickwork and with ? x ?mm triangular fillet at bottom

m

Not Priced

1407

?mm Turn-downs average ?mm high

m

Not Priced

1408

30 x 30mm Triangular fillets

m

Not Priced

1409

? x ? Triangular fillets

m

Not Priced

1410

0,6mm Galvanised sheet steel flashings

1411

Cover flashings 150mm girth, including sealing top edge with mastic in and including groove in brickwork

m

Not Priced



Not Priced

1403

1404

1405

1406

1412

PROTECTIVE STONE DRESSING

1413

Clean crushed stone dressing free of pyrite or other contaminants, of 20 - 25mm stone evenly spread with larger stones around outlets

1414

Clean river stone pebble of 20 - 30mm pebbles evenly spread with larger stones around outlets

1415

50mm Thick on waterproofing to flat roofs

Carried forward Bill No 9 Waterproofing ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-132-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1416

PROTECTIVE ROOFING PAINT

1417

Two coats bituminous aluminium paint

1418

Two coats heavy duty acrylic emulsion paint

1419

On waterproofing to roofs



Not Priced

1420

On waterproofing to box gutters



Not Priced

1421

PROTECTIVE SHEETING

1422

Type 40 bituminous fibreglass felt laid loose

1423

On waterproofing to roofs



Not Priced

1424

PROTECTIVE PAVING

1425

? x ? x ?mm Fibre-cement (precast concrete?) tile paving with ?mm wide continuous joints in both directions, bedded and jointed in hot bitumen including prime coat to backs of tiles

1426

On waterproofing to flat roofs



Not Priced

1427

On waterproofing to turn-ups not exceeding 300mm high

m

Not Priced

1428

WATERSTOPS

1429

"?" PVC waterstops cast into concrete

1430

"?" Rubber waterstops cast into concrete

1431

?mm Double bulb waterstops

m

Not Priced

1432

?mm Centre bulb waterstops

m

Not Priced

1433

Fused angle intersection to ?mm waterstops

No

Not Priced

1434

Fused T-intersection to ?mm waterstops

No

Not Priced

1435

SEALING STRIPS, JOINT SEALANTS, ETC

1436

Bitumen impregnated foam plastic joint sealing strips

1437

Pre-compressed bitumen impregnated foam plastic joint sealing strips

1438

? x ?mm In joints between frames and walls

m

Not Priced

Carried forward Bill No 9 Waterproofing ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-133-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1439

? x ?mm In expansion joints

1440

"?" mastic sealing compound including backing cord, bond breaker, primer, etc

1441

"?" two-part grey polysulphide sealing compound including backing cord, bond breaker, primer, etc

1442

"?" silicone sealing compound including backing cord, bond breaker, primer, etc

1443

"?" polyurethane sealing compound including backing cord, bond breaker, primer, etc

1444

R

Not Priced

m

Not Priced

6 x 10mm In saw cut joints in floors

m

Not Priced

1445

? x ?mm In saw cut joints in floors

m

Not Priced

1446

? x ?mm In expansion joints in tiled floors etc

m

Not Priced

1447

? x ?mm In vertical expansion joints in tiled walls etc

m

Not Priced

1448

? x ?mm In expansion joints in floors including raking out expansion joint filler as necessary

m

Not Priced

? x ?mm In vertical expansion joints including raking out expansion joint filler as necessary

m

Not Priced

? x ?mm In expansion joints in soffits including raking out expansion joint filler as necessary

m

Not Priced

1449

1450

Carried to summary Bill No 9 Waterproofing ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-134-

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

Quantity

Rate

Amount

5521

BILL NO ?

5522

ROOF COVERINGS

5523

User note

5524

Where battens for roof coverings form part of the plate nailed timber roof truss design it shall be included under the roof construction in the "Carpentry and Joinery" trade and not under this trade

5525

SLATES

5526

? x ?mm "?" slates laid in single thickness with a head lap of 90mm on underlay of bituminous roofing felt in accordance with SANS 92 Type 60 faced with 0,1mm aluminium foil over half its width with 150mm head laps and with tops of slates nailed with galvanised steel (copper?) clout nails to and including ? x ?mm sawn sofwood battens at ?mm centres

5527

? x ?mm "?" slates laid in double thickness with a head lap of 75mm and nailed along centre with galvanised steel (copper?) clout nails to and including ? x ?mm sawn softwood battens at ?mm centres

5528

? x ? x ?mm Black (charcoal? red? bright red? brown? white?) coloured plain (textured?) mitred (unmitred?) cement-fibre slates nailed with galvanised steel (copper?) clout nails to and including ? x ?mm sawn softwood battens at ?mm centres and fastened together with copper disc rivets

5529

Roof covering with pitches not exceeding 25 degrees



Not Priced

5530

Roof covering with pitches not exceeding 25 degrees, circular across the fall to ?m radius



Not Priced

5531

Roof covering circular along the fall to ?m radius



Not Priced

5532

Roof covering with a ? degree pitch



Not Priced

5533

Roof covering to conical shape with a ? degree pitch and a radius varying from ?m to ?m, including cutting slates to wedge shape



Not Priced

5534

Side cladding to gables etc



Not Priced

5535

Side cladding to gables etc circular on plan to ?m radius



Not Priced

Carried forward Bill No 10 Roof Coverings ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-135-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5536

Soffit cladding to eaves overhangs etc



Not Priced

5537

Roof covering and side cladding to dormers, turrets, etc



Not Priced

5538

Circular cutting

m

Not Priced

5539

Extra on roof covering for double course at eaves including fixing clips and ? x ?mm sawn softwood tilting fillet

m

Not Priced

Close cut and mitred ridge including soakers of bituminous roofing felt in accordance with SANS 92 Type 60 and necessary additional battens

m

Not Priced

Close cut and mitred hip including soakers of bituminous roofing felt in accordance with SANS 92 Type 60 and necessary additional battens

m

Not Priced

Close cut and mitred valley including soakers of bituminous roofing felt in accordance with SANS 92 Type 60 and necessary additional battens

m

Not Priced

Close cut and mitred vertical angle including soakers of bituminous roofing felt in accordance with SANS 92 Type 60 and necessary additional battens

m

Not Priced

5540

5541

5542

5543

5544

TILES

5545

User note

5546

The fixing recommendations of the manufacturer of the tiles used for the specific region and/or situation are to be incorporated as supplementary preambles

5547

? x ?mm "?" concrete (terra cotta?) tiles nailed with non-corrosive nails and/or fixed with suitable non-corrosive clips as required to and including ? x ?mm sawn softwood battens at ?mm centres

5548

? x ?mm "?" concrete (terra cotta?) tiles nailed with non-corrosive nails and/or fixed with suitable non-corrosive clips as required to and including ? x ? mm sawn softwood battens at ?mm centres over and including an underlay of 250 micron polyethelene sheeting in accordance with SANS 952 Type E fixed to rafters under battens with minimum laps of 150mm

Carried forward Bill No 10 Roof Coverings ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-136-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5549

? x ?mm concrete (terra cotta?) tiles nailed with non-corrosive nails and/or fixed with suitable non-corrosive clips as required to and including ? x ?mm sawn softwood battens at ?mm centres over and including an underlay of multi-layered reinforced aluminium foil faced one side sheeting in accordance with SANS 1381-4 with a mass of not less than 218g/m² and a Class I fire rating in accordance with SANS 0177-3 fixed under battens with minimum laps of 150mm

5550

Roof covering with pitches not exceeding 25 degrees



Not Priced

5551

Roof covering with a ? degree pitch



Not Priced

5552

Side cladding to gables etc



Not Priced

5553

Soffit cladding to eaves overhangs etc



Not Priced

5554

Roof covering and side cladding to dormers, turrets, etc



Not Priced

5555

Circular cutting

m

Not Priced

5556

Open valleys including raking cutting on both sides (valley gutters elsewhere)

m

Not Priced

Close cut and fitted valleys including raking cutting on both sides (valley gutters elsewhere)

m

Not Priced

Extra on roof covering for ? x ?mm sawn softwood tilting fillets

m

Not Priced

Ridges of tiles to match roofing tiles, bedded and pointed in 1:3 tinted cement mortar, including 300mm wide strip of 375 micron embossed dampproof course in accordance with SANS 952 Type B underlay

m

Not Priced

Hips of tiles to match roofing tiles, bedded and pointed in 1:3 tinted cement mortar, including 300mm wide strip of 375 micron embossed dampproof course in accordance with SANS 952 Type B underlay and raking cutting to tiles on both sides

m

Not Priced

Verges of capping tiles to match roofing tiles, fixed with non-corrosive fixing accessories

m

Not Priced

No

Not Priced

5557

5558

5559

5560

5561

5562

5563

Purpose made tile to end of ridge, bedded and pointed in 1:3 tinted cement mortar

SHINGLES

Carried forward Bill No 10 Roof Coverings ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-137-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5564

User note:

5565

Western red cedar is the wood normally used for making shingles and is imported. Other types of wood such as oak, elm, pine and teak have apparently not given satisfactory results. The nominal length of western red cedar shingles is 400mm and the width varies from 75 to 300mm

5566

The minimum pitch recommended for a 125mm gauge (i.e. 125mm length exposed to the weather) is 30 degrees, but if the gauge is decreased the pitch may be reduced (e.g. 20 degrees with a 95mm gauge)

5567

Close boarding and underlays are not necessary for prevention of water penetration as the shingles lie closely upon one another, thus ensuring a draught proof roof

5568

Western red cedar shingles in approximately 400mm lengths and widths varying from 75 to 300mm, laid with 125mm gauge and minimum side laps of 38mm and nailed with non-corrosive clout nails to and including ? x ?mm sawn softwood battens at 125mm centres

5569

Roof covering with pitches not exceeding 25 degrees



Not Priced

5570

Roof covering with a ? degree pitch



Not Priced

5571

Side cladding to gables etc



Not Priced

5572

Soffit cladding to eaves overhangs etc



Not Priced

5573

Roof covering and side cladding to dormers, turrets, etc



Not Priced

5574

Circular cutting

m

Not Priced

5575

Extra on roof covering for double course at eaves including ? x ?mm sawn softwood tilting fillet

m

Not Priced

Close cut and mitred hips including 0,6mm thick galvanised sheet iron (sheet copper? sheet aluminium?) soakers and necessary additional battens

m

Not Priced

Close cut and mitred valleys including 0,6mm thick galvanised sheet iron (sheet copper? sheet aluminium?) soakers and necessary additional battens

m

Not Priced

5576

5577

Carried forward Bill No 10 Roof Coverings ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-138-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5578

5579

R

Not Priced

Saddle ridges of narrow width shingles laid with top ends lapped alternately and minimum side laps of 38mm and nailed with non-corrosive clout nails, including 0,6mm thick galvanised sheet iron (sheet copper? sheet aluminium?) lining

m

Not Priced

Clean down and oil shingle roof covering with two saturation coats of special shingle roofing oil in accordance with the manufacturer's instructions



Not Priced

5580

THATCH

5581

User note

5582

Grass in the Gauteng area suitable for thatch is the hyparrhenia species and is obtainable in lengths varying from 760 to 1020mm

5583

The minimum density to which the above mentioned grass should be compacted is 30kg/m²/150mm thickness

5584

The fibre blanket usually consists of an interlay or an underlay of multi-layered fire-retardent reinforced double-sided aluminium foil sheeting

5585

150mm Thick thatch of hand cut grass of the hyparrhenia? species in lengths varying from 760 to 1020mm laid in bundles of suitable size, compacted to a minimum density of 30kg/m²/150 mm thickness and fixed by means of suitable fixing rods interlaced through and over the bundles at not exceeding 600mm centres and secured with tarred twine to and including eucalyptus battens CCA treated in accordance with SANS 457-2, varying in diameter from 20 to 40mm, spaced at maximum 300mm centres generally and at closer centres nearer to eaves, including a fire-retardent interlay of multi-layered reinforced double-sided aluminium foil sheeting in accordance with SANS 1381-4 with a mass of not less than 272g/m² and a Class I fire rating in accordance with SANS 0177-3

5586

Covering to general roof slopes



Not Priced

5587

Covering to general roof slopes including a spreadlayer to exposed soffit



Not Priced

Covering to dormers, turrets, etc



Not Priced

5588

Carried forward Bill No 10 Roof Coverings ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-139-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5589

5590

R

Not Priced

Ridges formed by extending covering above ridge level on the one roof slope, bending over and down on the opposite slope and fixing and securing as described for roof covering and repeating the process on the other roof slope including covering with galvanised wire bird netting 900mm girth and necessary additional fixing rods

m

Not Priced

Purpose made continuous glass fibre ridge cappings of not less than 1,5mm thick material 1300mm girth and in suitable lengths, securely fixed to thatch with 75mm wide lapped and sealed heading joints including grass filling under

m

Not Priced

5591

Extra over ridge capping for purpose made angle piece

No

Not Priced

5592

Extra over ridge capping for purpose made curved returned end piece

No

Not Priced

5593

PROFILED FIBRE-CEMENT SHEETING AND ACCESSORIES

5594

User note

5595

When the pitch of the roof is less than 9 degrees or if dustproofing is required then the description of roof covering "with side and end laps sealed" is to be used

5596

"?" sheeting and accessories, fixed to timber (steel?) purlins or rails

5597

"?" profiled sheeting and accessories with "?" factory applied polyacrylic emulsion paint finish on one side (both?) side(s) fixed to timber (steel?) purlins or rails

5598

Roof covering with pitches not exceeding 25 degrees



Not Priced

5599

Roof covering with a ? degree pitch



Not Priced

5600

Roof covering with pitches not exceeding 25 degrees and with side and end laps sealed with 12 x 25mm closed cell bitumen impregnated polyurethane foam strips



Not Priced

5601

Side cladding



Not Priced

5602

Soffit cladding



Not Priced

5603

Circular cutting

m

Not Priced

Carried forward Bill No 10 Roof Coverings ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-140-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5604

5605

R

Not Priced

Extra over roof coverings (side cladding? soffit cladding?) for ?mm (?kg/m²?) semi-opaque ?% light transmission type ? translucent polycarbonate sheet panels



Not Priced

Extra over roof coverings for soaker flange sheet suitable for type ? ventilator with ? x ?mm throat

No

Not Priced

5606

Side apron flashings

m

Not Priced

5607

End apron flashings

m

Not Priced

5608

Plain fixed angle ridge (hip?) cappings

m

Not Priced

5609

Plain adjustable ridge (hip?) cappings

m

Not Priced

5610

Close fitting adjustable ridge cappings

m

Not Priced

5611

Fixed angle sawtooth ridge cappings

m

Not Priced

5612

Adjustable sawtooth ridge cappings

m

Not Priced

5613

Fixed angle wide profile ridge sheets ?mm girth

m

Not Priced

5614

Fixed angle wide profile curved ridge sheets ?mm girth

m

Not Priced

5615

Birdproofing

m

Not Priced

5616

Eaves fillers

m

Not Priced

5617

Straight sill flashings

m

Not Priced

5618

U-flashings

m

Not Priced

5619

Hip end cap

No

Not Priced

5620

Ridge end cap

No

Not Priced

5621

Junction piece at intersection of ridge with two hip cappings

No

Not Priced

5622

PROFILED METAL SHEETING AND ACCESSORIES

Carried forward Bill No 10 Roof Coverings ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-141-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5623

User note

5624

Profiled metal sheeting is available in various thicknesses

R

Not Priced

Usually Z275 spelter galvanising is used in inland areas and Z600 spelter galvanising for coastal areas. However galvanised sheeting is generally not used in coastal areas When the pitch of troughed roof covering is less than 5 degrees or if dustproofing is required then the description of roof coverings "with side laps sealed" is to be used Where roof coverings are fixed on top of rigid board insulation to purlins etc they are to be described as such Note that besides galvanised steel, sheeting is also available in corten steel, stainless steel, copper and aluminium

5625

0,5 (0,6? 0,8?)mm Z275 (Z600?) spelter galvanised corrugated sheet steel and accessories, fixed to timber (steel?) purlins or rails

5626

0,5 (0,6? 0,8?)mm Z275 (Z600?) spelter galvanised corrugated sheet steel and accessories, with silicone polyester (baked enamel?) paint finish on one side, fixed to timber (steel?) purlins or rails

5627

0,5 (0,6? 0,8?)mm Z275 (Z600?) spelter embossed galvanised troughed sheet steel in single lengths and accessories, fixed to timber (steel?) purlins or rails

5628

0,5 (0,6? 0,8?)mm Z275 (Z600?) spelter embossed galvanised troughed sheet steel in single lengths and accessories, with baked enamel paint finish on one side, fixed to timber (steel?) purlins or rails

5629

Roof covering with pitches not exceeding 25 degrees



Not Priced

5630

Roof covering with a ? degree pitch



Not Priced

5631

Roof covering with pitches not exceeding 25 degrees and with side laps seam stitched



Not Priced

Roof covering with pitches not exceeding 25 degrees with side laps sealed with 6 x 20mm closed cell bitumen impregnated polyurethane foam strips and seam stitched



Not Priced

5632

Carried forward Bill No 10 Roof Coverings ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-142-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5633

Roof covering circular along the fall to ?m radius



Not Priced

5634

Roof covering circular along the fall to ?m radius with side laps sealed with 6 x 20mm closed cell bitumen impregnated polyurethane foam strips and seam stitched



Not Priced

5635

Side cladding



Not Priced

5636

Side cladding circular on plan to ?m radius



Not Priced

5637

Soffit cladding



Not Priced

5638

Roof covering and side cladding to dormers, turrets, etc



Not Priced

5639

Circular cutting

m

Not Priced

5640

Extra over roof covering (side cladding? soffit cladding?) for ?mm (?kg/m²?) semi-opaque ?% light transmission type ? translucent polycarbonate sheet panels



Not Priced

Extra over roof covering for ? degree crank occuring ?mm and ?mm respectively from ends of sheets to form ridge

m

Not Priced

Extra over roof covering for ? degree bullnose to ?mm radius, at ends

m

Not Priced

Extra over roof covering for ? degree curved turn-up to ?mm radius, at ends

m

Not Priced

5644

Rolled edges at verge

m

Not Priced

5645

Ridge cappings ?mm girth

m

Not Priced

5646

Hip cappings ?mm girth

m

Not Priced

5647

Cover flashings ?mm girth

m

Not Priced

5648

Side wall flashings ?mm girth

m

Not Priced

5649

Head wall flashings ?mm girth

m

Not Priced

5650

Gable trims ?mm girth

m

Not Priced

5651

Apex flashings ?mm girth

m

Not Priced

5652

Corner trims ?mm girth

m

Not Priced

5653

Apron flashings ?mm girth

m

Not Priced

5641

5642

5643

Carried forward Bill No 10 Roof Coverings ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-143-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5654

Z-profile flashings ?mm girth

m

Not Priced

5655

Drip flashing ?mm girth

m

Not Priced

5656

Sill flashings ?mm girth

m

Not Priced

5657

Jamb flashings ?mm girth

m

Not Priced

5658

Narrow and broad flute closers ?mm girth

m

Not Priced

5659

Narrow and broad flute closers ?mm girth, raking at valleys or hips

m

Not Priced

5660

Moulded narrow and broad rib polyethylene filler blocks

m

Not Priced

5661

Moulded narrow and broad rib polyethylene filler blocks, raking at valley or hips

m

Not Priced

5662

0,5 (0,6? 0,8?)mm Z275 (Z600?) spelter galvanised ribbed sheet steel in single lengths and accessories, fixed to timber (steel?) purlins or rails

5663

0,5 (0,6? 0,8?)mm Z275 (Z600?) spelter galvanised ribbed sheet steel in single lengths and accessories with silicone polyester paint finish on one side, fixed to timber (steel?) purlins or rails

5664

Roof covering with pitches not exceeding 25 degrees



Not Priced

5665

Roof covering with a ? degree pitch



Not Priced

5666

Side cladding



Not Priced

5667

Soffit cladding



Not Priced

5668

Roof covering and side cladding to dormers, turrets, etc



Not Priced

5669

Circular cutting

m

Not Priced

5670

Extra over roof covering (side cladding? soffit cladding?) for ?mm (?kg/m²?) semi-opaque ?% light transmission type ? polycarbonate translucent panels



Not Priced

Extra over roof covering for ? degree crank occuring ?mm and ?mm respectively from ends of sheets to form ridge including rib caps and sealing

m

Not Priced

Extra over roof covering for ? degree bullnose to ?mm radius, at ends

m

Not Priced

5671

5672

Carried forward Bill No 10 Roof Coverings ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-144-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5673

R

Not Priced

Extra over roof covering for ? degree curved turn-up to ?mm radius, at ends

m

Not Priced

5674

Ridge coverings ?mm girth

m

Not Priced

5675

Hip coverings ?mm girth

m

Not Priced

5676

Cover flashings ?mm girth

m

Not Priced

5677

Side wall flashings ?mm girth

m

Not Priced

5678

Head wall flashings ?mm girth

m

Not Priced

5679

Serrated top end closers ?mm girth

m

Not Priced

5680

? x ?mm Standard fascia gutters fixed to roof sheeting with and including clips

m

Not Priced

5681

Extra over for stopped end

No

Not Priced

5682

Extra over for angle

No

Not Priced

5683

Extra over for outlet with nozzle for and jointing to ? x ?mm diameter rainwater pipe including domical grating

No

Not Priced

5684

?mm (?kg/m²?) ? profile semi-opaque ?% light transmission type ? translucent polycarbonate sheeting with ?mm side laps and ?mm end laps, fixed to timber (steel?) purlins or rails

5685

Roof covering with pitches not exceeding 25 degrees



Not Priced

5686

Roof covering with a ? degree pitch



Not Priced

5687

Roof covering with pitches not exceeding 25 degrees with side laps sealed with 6 x 20mm closed cell bitumen impregnated polyurethane foam strips and seam stitched



Not Priced

5688

Side cladding



Not Priced

5689

Circular cutting

m

Not Priced

5690

ROOF VENTILATORS

Carried forward Bill No 10 Roof Coverings ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-145-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5691

Manufactured by "?"

5692

Type ? fibre-cement plain wing continuous ridge ventilators to 30 degrees angle and with base wing 230mm wide fixed through fibre-cement roof sheeting to steel purlins including watertight heading joints, necessary sealing strips, fixing accessories, etc

R

Not Priced

m

Not Priced

5693

Extra over for closed end piece

No

Not Priced

5694

Type ? fibre-cement ventilator fixed on soaker flange sheet (soaker flange sheet elsewhere) including sealing strips, fixing accessories, etc

No

Not Priced

Type ? galvanised sheet steel multi-purpose ventilator 1,83m long fixed through troughed roof sheeting to steel purlins including flashings, closers, sealing strips, etc

No

Not Priced



Not Priced



Not Priced

5695

5696

ROOF AND WALL INSULATION

5697

Multi-layered reinforced double-sided aluminium foil sheeting in accordance with SANS 1381-4 with a mass of not less than 293g/m² and a Class I fire rating in accordance with SANS 0177-3

5698

Type ? polyethelene bubblefold aluminium foil faced one side sheeting

5699

Type ? polyethelene bubblefold aluminium foil faced both sides sheeting

5700

Insulation sheeting laid taut over purlins (at approximately ?mm centres) and fixed concurrent with roof covering with minimum 150mm stapled laps including galvanised (PVC coated?) steel straining wires at not exceeding 400mm centres and double-sided tape at edges where required

5701

50mm Thick "?" aluminium foil faced fibreglass blanket

5702

Insulation blanket laid taut over purlins (at approximately ?mm centres) and fixed concurrent with roof covering with stapled longitudinal flap joints, including fixing at top and bottom edges to purlins with and including hoop iron straps

Carried forward Bill No 10 Roof Coverings ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-146-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5703

Insulation blanket laid taut over purlins (at approximately ?mm centres) and fixed concurrent with roof covering with stapled longitudinal flap joints, including galvanised (PVC coated?) steel straining wires at not exceeding 300mm centres and fixing at top and bottom edges to purlins with and including hoop iron straps

R

Not Priced



Not Priced

5704

?mm Thick "?" aluminium foil faced polyisocyanurate foam core rigid board

5705

?mm Thick "?" aluminium foil faced polyisocyanurate foam core rigid board with clear lacquer finish on one side (white lacquer finish on one side ?)

5706

Insulation boarding in ?mm widths with longitudinal flap joints, laid over purlins (at approximately ?mm centres) and fixed concurrent with roof covering, including holes through boards etc



Not Priced

Insulation boarding in ?mm widths with "?" H-section aluminium bearers at longitudinal joints, laid over purlins (at approximately ?mm centres) and fixed concurrent with roof covering, including holes through boards etc



Not Priced

Insulation boarding in ?mm widths with "?" H-section aluminium bearers at longitudinal joints, placed vertically against girts, bearers, etc (at approximately ?mm centres) and fixed concurrent with vertical cladding, including holes through boards etc



Not Priced

5707

5708

5709

FLAT SHEET METAL

5710

0,56mm Grade 004 HC sheet copper (1,2mm sheet aluminium of 3004/H4 alloy?) laid on boarding (boarding elsewhere) and sheets jointed in the direction of the flow by double-lock welts into standing seams (?mm high, overcloak ?mm, undercloak ?mm) and across the fall by double-lock welts (?mm wide, overcloak ?mm, undercloak ?mm) and attached to roof along standing seams with clips ?mm wide and ?mm girth cut from sheeting material, each double nailed to boarding with non-corrosive clout nails, bent up into seam and folded concurrent with sheeting in forming the welt

Carried forward Bill No 10 Roof Coverings ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-147-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5711

0,56mm Grade 004 HC sheet copper (1,2mm sheet aluminium of 3004/H4 alloy?) laid on boarding (boarding elsewhere) including an underlay of bituminous roofing felt in accordance with SANS 92 Type 60, butt jointed and fixed with non-corrosive clout nails with sheets jointed in the direction of the flow by double-lock welts into standing seams (?mm high, overcloak ?mm, undercloak ?mm) and across the fall by double-lock welts (?mm wide, overcloak ?mm, undercloak ?mm) and attached to roof along standing seams with clips ?mm wide and ?mm girth cut from sheeting material, each double nailed through underlay to boarding with non-corrosive clout nails, bent up into seam and folded concurrent with sheeting in forming the welt

5712

Roof covering with pitches not exceeding 25 degrees



Not Priced

5713

Roof covering with a ? degree pitch



Not Priced

5714

Roof covering circular along the fall to ?m radius



Not Priced

5715

Roof covering with pitches not exceeding 25 degrees, circular across the fall to ?m radius



Not Priced

5716

Side cladding to gables etc



Not Priced

5717

Roof covering and side cladding to dormers, turrets, etc



Not Priced

5718

Circular cutting

m

Not Priced

5719

SHEET METAL FLASHINGS, LININGS, COPINGS, ETC

5720

0,6mm Galvanised sheet steel

5721

0,6mm Galvanised sheet steel with silicone polyester (baked enamel?) paint finish on one side

5722

0,6mm "?" sheet aluminium

5723

Flashings



Not Priced

5724

Stepped cover flashings



Not Priced

5725

Stepped cover flashings to roof pitches exceeding 25 degrees



Not Priced

5726

Soakers



Not Priced

5727

Linings to valleys with riveted and sealed joints



Not Priced

Carried forward Bill No 10 Roof Coverings ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-148-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5728

Linings to box gutters with riveted and sealed joints



Not Priced

5729

Antguards



Not Priced

5730

Circular cutting

m

Not Priced

5731

Apron flashings ?mm girth

m

Not Priced

5732

Cover flashings ?mm girth

m

Not Priced

5733

Cappings ?mm girth four times bent along length, with riveted and sealed joints, sprung over and including suitable galvanised steel brackets at 500mm centres, plugged to brickwork or concrete

m

Not Priced

No

Not Priced

5734

Extra over for riveted and sealed angle

Carried to summary Bill No 10 Roof Coverings ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-149-

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

4819

BILL NO ?

4820

CARPENTRY AND JOINERY

4821

SUPPLEMENTARY PREAMBLES

4822

Fixing

4823

Items described as "nailed" shall be deemed to be fixed with hardened steel nails or pins, or to be shot-pinned, to brickwork or concrete

4824

Items described as "plugged" shall be deemed to include screwing to fibre, plastic or metal plugs at not exceeding 500mm centres, and where described as "bolted", the bolts have been given elsewhere

4825

Joinery

4826

Descriptions of frames shall be deemed to include frames, transomes, rails, etc

4827

Descriptions of hardwood joinery shall be deemed to include sinking and pelleting heads and nuts of bolts

4828

Decorative thermosetting plastic laminate covering

4829

Laminate covering shall be glued under pressure and edge strips of same shall be butt jointed at junctions with adjacent similar finish

4830

ROOFS ETC

4831

Sawn softwood grade ?

4832

Wrought softwood grade ?

4833

User note

4834

The following 2 items will only occur when the battens are not included under the roof covering or plate nailed roof construction

4835

? x ?mm Battening at ?mm centres for tile (slate?) roof covering

4836

Extra over for ? x ?mm tilting fillets at eaves

4837

?mm Gutter boarding

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-150-

Quantity

Rate

Amount



Not Priced

m

Not Priced



Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4838

?mm Boarding to tank stands



Not Priced

4839

?mm Tongued and grooved roof boarding in ?mm widths



Not Priced

4840

Raking cutting to boarding

m

Not Priced

4841

Circular cutting to boarding

m

Not Priced

4842

? x ?mm Wall plates

m

Not Priced

4843

? x ?mm Wall plates bolted

m

Not Priced

4844

? x ?mm Bracing

m

Not Priced

4845

? x ?mm Hangers

m

Not Priced

4846

? x ?mm Runners

m

Not Priced

4847

? x ?mm Trimmers

m

Not Priced

4848

? x ?mm Sprockets

m

Not Priced

4849

? x ?mm Ceiling joists in lengths not exceeding 2,4m

m

Not Priced

4850

? x ?mm Ceiling joists in lengths exceeding ?m and not exceeding ?m

m

Not Priced

4851

? x ?mm Ceiling joists in lengths exceeding 6,6m

m

Not Priced

4852

? x ?mm Common rafters in lengths not exceeding 2,4m

m

Not Priced

4853

? x ?mm Common rafters in lengths exceeding ?m and not exceeding ?m

m

Not Priced

4854

? x ?mm Common rafters in lengths exceeding 6,6m

m

Not Priced

4855

? x ?mm Bearers bolted

m

Not Priced

4856

? x ?mm Bearers in lengths not exceeding 2,4m

m

Not Priced

4857

? x ?mm Bearers in lengths exceeding ?m and not exceeding ?m

m

Not Priced

4858

? x ?mm Bearers in lengths exceeding 6,6m

m

Not Priced

4859

? x ?mm Bolted roof truss members in lengths not exceeding 2,4m

m

Not Priced

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-151-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4860

R

Not Priced

? x ?mm Bolted roof truss members in lengths exceeding ?m and not exceeding ?m

m

Not Priced

? x ?mm Bolted roof truss members in lengths exceeding 6,6m

m

Not Priced

4862

? x ?mm Valley boards

m

Not Priced

4863

? x ?mm Gangboards

m

Not Priced

4864

? x ?mm Cross battens at hips, valleys, etc

m

Not Priced

4865

? x ?mm Tilting fillets

m

Not Priced

4866

? x ?mm Purlins

m

Not Priced

4867

? x ?mm Purlins bolted

m

Not Priced

4868

? x ?mm Splayed purlins

m

Not Priced

4869

? x ?mm Blocking piece ?mm long

No

Not Priced

4870

Wrought laminated Saligna

4871

Wrought laminated Saligna (architectural finish)

4872

? x ?mm Bearers bolted to walls etc

m

Not Priced

4873

? x ?mm Bolted beams, pergola beams, etc

m

Not Priced

4874

? x ?mm Bolted arched beam ?mm girth circular across depth to ?mm inner radius

No

Not Priced

4861

4875

Sundries

4876

Wrought faces on sawn timbers



Not Priced

4877

Two coats creosote on sawn timbers



Not Priced

4878

?mm Long wrought end to ? x ?mm sawn timber

No

Not Priced

4879

?mm Long wrought and shaped end to ? x ?mm sawn timber

No

Not Priced

4880

?mm Diameter "Bulldog" double-sided timber connector

No

Not Priced

4881

?mm Diameter split ring timber connector including cutting grooves in timber

No

Not Priced

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-152-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4882

4883

R

Not Priced

? x ?mm Diameter galvanised wire tie ?mm girth, wrapped around rafter and purlin with ends twisted together

No

Not Priced

? x ?mm Galvanised hoop iron roof tie ?m girth with both ends fixed to timber

No

Not Priced



Not Priced

4884

PLATE NAILED TIMBER ROOF TRUSS CONSTRUCTION ETC

4885

SUPPLEMENTARY PREAMBLES

4886

Trusses are at maximum ?mm centres

4887

Roof coverings are ? on purlins (battens?)

4888

Ceilings are ?mm sheeting (with skimming?) on ? x ?mm brandering

4889

References given in descriptions refer to the respective types of trusses detailed on the architect's/engineer's drawings numbered ? annexed to these bills of quantities (accompanying these bills of quantities?) for tender purposes

4890

Dimensions in descriptions of trusses are nominal and actual measurements are to be obtained from the architect/engineer and/or taken on site before design or fabrication commences

4891

Sawn softwood grade ?

4892

? x ?mm Battening at ?mm centres for tile (slate?) roof covering

4893

? x ?mm Wall plates

m

Not Priced

4894

? x ?mm Longitudinal bracing

m

Not Priced

4895

? x ?mm Cross bracing

m

Not Priced

4896

? x ?mm Purlins

m

Not Priced

4897

Truss type ?, ? x ?mm high overall

No

Not Priced

4898

Truss type ?, ? x ?mm high overall with ?mm eaves projection on one (both?) side(s?)

No

Not Priced

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-153-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4899

4900

4901

R

Not Priced

Double hipped end to double pitched roof ? x ?mm overall on plan x ?mm high overall, including part trusses, jack rafters, permanent bracing, etc (purlins (battens?) elsewhere)

No

Not Priced

Hip and valley intersection to double pitched roof, ? x ?mm overall on plan x ?mm high overall, including part trusses, jack rafters, permanent bracing, etc (purlins (battens?) elsewhere)

No

Not Priced

Roof construction to double pitched roof with two hipped ends, ? x ?m overall on plan x ?mm high overall, including trusses, jack rafters, permanent bracing and ? x ?mm purlins (battens?) at ? centres for roof covering (wall plates elsewhere)

Item

Not Priced

4902

Extra over for tilting fillets at eaves

m

Not Priced

4903

Extra over for wrought splayed purlins at eaves

m

Not Priced

4904

Extra over for ?mm long wrought rafter foot

No

Not Priced

4905

Extra over for ?mm long wrought and shaped rafter foot

No

Not Priced

4906

EAVES, VERGES, ETC

4907

Sawn softwood

4908

Wrought softwood

4909

Wrought meranti

4910

Slatted eaves soffit covering of ? x ?mm wide slats at ?mm centres



Not Priced

Slatted verge soffit covering of ? x ?mm wide slats at ?mm centres



Not Priced

Eaves soffit covering of ?mm tongued and grooved boarding in ?mm widths



Not Priced

Verge soffit covering of ?mm tongued and grooved boarding in ?mm widths



Not Priced

4911

4912

4913

4914

? x ?mm Branders

m

Not Priced

4915

? x ?mm Branders wrought on one face

m

Not Priced

4916

? x ?m Bearers

m

Not Priced

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-154-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4917

? x ?mm Hangers

m

Not Priced

4918

?mm Quadrant beads

m

Not Priced

4919

? x ?mm Beads

m

Not Priced

4920

?mm Half round cover strips

m

Not Priced

4921

? x ?mm Fascias and barge boards

m

Not Priced

4922

Medium (High?) density plain (textured?) fibre-cement flat sheets

4923

User note

4924

Medium density sheets are available in 4mm, 6mm, 9mm and 12mm thicknesses and high density sheets in 5mm, 10mm, 15mm and 20mm thicknesses Standard widths are 900mm and 1200mm High density fibre-cement sheets are recommended for eaves coverings

4925

?mm Eaves soffit covering (brandering elsewhere)



Not Priced

4926

?mm Eaves soffit covering including ? x ?mm sawn softwood branders along edges, along centre and at ?mm centres across sheets



Not Priced

4927

?mm Verge soffit covering (brandering elsewhere)



Not Priced

4928

?mm Verge soffit covering including ? x ?mm sawn softwood branders along edges and at ?mm centres across sheets



Not Priced

4929

Medium (High?) density plain (textured?) fibre-cement fascias and barge boards

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-155-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4930

User note

4931

High density plain fascias and barge boards are available in 10mm and 15mm thicknesses and medium density plain fascias and barge boards in 12mm thickness only

R

Not Priced

Textured fascias and barge boards are available in medium density only in thicknesses of 9mm and 12mm Standard widths are 150mm, 225mm and 300mm for plain fascias and barge boards and 150mm and 225mm for textured fascias and barge boards 4932

4933

? x ?mm Fascias and barge boards, including galvanised steel (plastic? aluminium?) H-profile joiners

m

Not Priced

12 x ?mm Grooved fascias and barge boards, including galvanised steel (plastic? aluminium?) H-profile joiners

m

Not Priced

m

Not Priced

Extra over ? x ?mm socketed barge board for standard curved end up

No

Not Priced

Extra over ? x ?mm socketed barge board for standard curved end down

No

Not Priced

Extra over ? x ?mm socketless barge board for ? degree cranked section, ?mm overall girth

No

Not Priced

Extra over ? x ?mm socketless barge board for curved section to ?mm extreme radius x ?mm extreme overall girth

No

Not Priced

Extra over ? x ?mm socketless barge boards for curved end up to ?mm extreme radius x ?mm extreme overall girth

No

Not Priced

Extra over ? x ?mm socketless barge board for curved end down to ?mm extreme radius x ?mm extreme overall girth

No

Not Priced

4934

Fibre-cement socketless (socketed?) barge boards

4935

? x ?mm Barge boards, including aluminium H-profile joiners etc

4936

4937

4938

4939

4940

4941

4942

FLOORS ETC

4943

Sawn softwood

4944

? x ?mm Battens wired to concrete (wire ties elsewhere)

m

Not Priced

4945

? x ?mm Floor joists in lengths not exceeding 2,4m

m

Not Priced

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-156-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4946

R

Not Priced

? x ?mm Floor joists in lengths exceeding ?m and not exceeding ?m

m

Not Priced

4947

? x ?mm Floor joists in lengths exceeding 6,6m

m

Not Priced

4948

? x ?mm Bearers in lengths not exceeding 2,4m

m

Not Priced

4949

? x ?mm Bearers in lengths exceeding ?m and not exceeding ?m

m

Not Priced

4950

? x ?mm Bearers in lengths exceeding 6,6m

m

Not Priced

4951

Wrought ?

4952

Flooring of ?mm tongued and grooved boarding in ?mm widths



Not Priced

4953

Raking cutting

m

Not Priced

4954

Circular cutting

m

Not Priced

4955

? x ?mm Risers with rebated top edge let into and including groove in treads

m

Not Priced

4956

? x ?mm Treads with rounded front edge

m

Not Priced

4957

Extra over flooring for ? x ?mm trapdoor with ? x ?mm framing and ? x ?mm rebated trimmers all round

No

Not Priced

No

Not Priced

4958

Wire ties

4959

4mm Diameter galvanised wire tie 450mm girth bent double, embedded in concrete, bound around floor batten and twisted together including saw cuts

4960

SKIRTINGS

4961

Wrought softwood

4962

Wrought meranti

4963

Wrought ?

4964

? x ?mm Skirtings

m

Not Priced

4965

? x ?mm Skirtings, nailed

m

Not Priced

4966

? x ?mm Skirtings, plugged

m

Not Priced

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-157-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4967

? x ?mm Skirtings stepped over treads and risers, nailed

m

Not Priced

4968

? x ?mm Skirtings stepped over treads and risers, plugged

m

Not Priced

4969

?mm Raking skirtings ?mm high extreme with bottom edge cut and fitted over treads and risers, plugged

m

Not Priced

4970

? x ?mm Skirtings including ?mm quadrant bead, nailed

m

Not Priced

4971

? x ?mm Skirtings including ?mm quadrant bead, plugged

m

Not Priced

4972

DOORS ETC

4973

SUPPLEMENTARY PREAMBLES

4974

Fire doors

4975

Fire doors are to be in accordance with SANS 1253

4976

Wrought softwood fanlights

4977

Wrought softwood fanlights hung to steel frames

4978

Wrought meranti fanlights

4979

Wrought meranti fanlights hung to steel frames

4980

Wrought ? fanlights

4981

Wrought ? fanlights hung to steel frames

4982

Wrought softwood doors

4983

Wrought softwood doors hung to steel frames

4984

Wrought meranti doors

4985

Wrought meranti doors hung to steel frames

4986

Wrought ? doors

4987

Wrought ? doors hung to steel frames

4988

?mm Fanlight ? x ?mm high of ?mm wide frame, in single pane, rebated all round including ? x ?mm glazing beads

No

Not Priced

?mm Fanlight ? x ?mm high of ?mm wide frame and mullion, in two panes, rebated all round including ? x ?mm glazing beads

No

Not Priced

4989

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-158-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4990

4991

4992

4993

4994

4995

4996

R

Not Priced

?mm Sash door ? x ?mm high of ?mm wide top rail and stiles and ?mm wide bottom rail, in single pane, rebated all round including ? x ?mm glazing beads

No

Not Priced

?mm Sash door ? x ?mm high of ?mm wide top rail, middle rail and stiles and ?mm wide bottom rail, in two panes, rebated all round including ? x ?mm glazing beads

No

Not Priced

?mm Sash double door ? x ?mm high with rebated (flush?) meeting stiles, each leaf of ?mm wide top rail and stiles and ?mm wide bottom rail, in single pane, rebated all round including ? x ?mm glazing beads

No

Not Priced

?mm Batten door ? x ?mm high of ? x ?mm top, middle and bottom ledges and braces and covered with ?mm tongued and grooved V-jointed one side vertical boarding

No

Not Priced

?mm Framed and ledged batten door ? x ?mm high of ?mm wide top rail and stiles, ? x ?mm middle ledge and ? x ?mm bottom ledge, filled in with ?mm tongued and grooved V-jointed one side vertical boarding with tongued and grooved joints to top rail and stiles and with inner edges of framing and abutting edges of boarding chamfered to form V-joint

No

Not Priced

?mm Framed, ledged and braced batten door ? x ?mm high of ?mm wide top rail and stiles, ? x ?mm middle ledge and braces and ? x ?mm bottom ledge, filled in with ?mm tongued and grooved V-jointed one side vertical boarding with tongued and grooved joints to top rail and stiles and with inner edges of framing and abutting edges of boarding chamfered to form V-joint

No

Not Priced

?mm Framed, ledged and braced batten double door ? x ?mm high with rebated (flush?) meeting stiles, each leaf of ?mm wide top rail and stiles, ? x ?mm middle ledge and braces and ? x ?mm bottom ledge, filled in with ?mm tongued and grooved V-jointed one side vertical boarding with tongued and grooved joints to top rail and stiles and with inner edges of framing and abutting edges of boarding chamfered to form V-joint

No

Not Priced

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-159-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4997

4998

4999

5000

5001

5002

5003

R

Not Priced

?mm Framed, ledged and braced batten door ? x ?mm high of ?mm wide top rail and stiles, ? x ?mm middle ledge and braces and ? x ?mm bottom ledge, filled in with ?mm tongued and grooved V-jointed one side vertical boarding with tongued and grooved joints to top rail and stiles and with inner edges of framing and abutting edges of boarding chamfered to form V-jointed and covered at back with ?mm plywood with matching veneer, let into and including rebates all round

No

Not Priced

?mm Single panel door ? x ?mm high of ?mm wide top rail and stiles, ? mm wide bottom rail and ? x ?mm middle ledge, filled in with ?mm tongued and grooved V-jointed one side vertical boarding with tongued and grooved joints to rails and stiles and with inner edges of framing and abutting edges of boarding chamfered to form V-joint

No

Not Priced

?mm Single panel door ? x ?mm high with ?mm wide top rail and stiles, ? mm wide bottom rail and ? x ?mm middle ledge and braces, filled in with ?mm tongued and grooved V-jointed one side vertical boarding with tongued and grooved joints to rails and stiles and with inner edges of framing and abutting edges of boarding chamfered to form V-joint

No

Not Priced

?mm Single panel stable door ? x ?mm high with rebated meeting rails, each leaf of ?mm wide top rail, stiles and bottom rail and ? x ?mm brace, filled in with ?mm tongued and grooved V-jointed one side vertical boarding with tongued and grooved joints to rails and stiles and with inner edges of framing and abutting edges of boarding chamfered to form V-joint

No

Not Priced

?mm Single panel double door ? x ?mm high with rebated (flush?) meeting stiles, each leaf of ?mm wide top rail and stiles, ? x ?mm bottom rail and ? x ?mm middle ledge and brace, filled in with ?mm tongued and grooved V-jointed one side vertical boarding with tongued and grooved joints to rails and stiles and with inner edges of framing and abutting edges of boarding chamfered to form V-joint

No

Not Priced

?mm Two panel door ? x ?mm high with ?mm wide top rail, middle rail and stiles, ?mm wide bottom rail and ?mm thick raised and fielded both sides panels

No

Not Priced

?mm Two panel double door ? x ?mm high, with rebated (flush?) meeting stiles, each leaf with ?mm wide top rail, middle rail and stiles, ?mm wide bottom rail and ?mm thick raised and fielded both sides panels

No

Not Priced

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-160-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5004

"?" hollow core flush doors with 3,2mm plain (prime-coated? finished white?) hardboard covering on both sides, hung to steel frames

5005

"?" hollow core flush doors with commercial veneer

5006

"?" hollow core flush doors with commercial veneer, hung to slide

5007

"?" hollow core flush doors with commercial veneer, hung to steel frames

5008

"?" semi-solid flush doors with 3,2mm plain (prime-coated? finished white?) hardboard covering on both sides, hung to steel frames

5009

"?" semi-solid flush doors with ? veneer

5010

"?" semi-solid flush doors with ? veneer, hung to steel frames

5011

"?" solid chipcore flush doors with ? veneer

5012

"?" solid chipcore flush doors with ? veneer, hung to steel frames

5013

"?" solid laminated external quality flush doors with ? veneer

5014

"?" solid laminated external quality flush doors with ? veneer, hung to steel frames

5015

40mm (44mm?) Door ? x ?mm high

No

Not Priced

5016

40mm (44mm?) Double door ? x ?mm high with flush/rebated meeting edges

No

Not Priced

40mm (44mm?) Double door ? x ?mm high with rounded vertical edges

No

Not Priced

40mm (44mm?) Double door ? x ?mm high with ?mm and ?mm wide unequal leaves, with rebated (flush?) meeting edges

No

Not Priced

40mm (44mm?) Door ? x ?mm high with ? x ?mm framed opening fitted with ? x ?mm wrought ? glazing beads on both sides

No

Not Priced

5017

5018

5019

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-161-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5020

5021

R

Not Priced

40mm (44mm?) Double door ? x ?mm high with rebated (flush?) meeting edges, each leaf with ? x ?mm framed opening fitted with ? x ?mm wrought ? glazing beads on both sides

No

Not Priced

Extra over for ? x ?mm framed opening for metal louvre unit (louvre unit elsewhere)

No

Not Priced

5022

"?" doors

5023

Type ? glazed door ? x ?mm high

No

Not Priced

5024

Type ? batten door ? x ?mm high

No

Not Priced

5025

Type ? panel door ? x ?mm high

No

Not Priced

5026

"?" fire doors with ? veneer

5027

User note

5028

Fire doors are generally available in Class A (1 hour fire rating) and Class B (2 hour fire rating)

5029

Class ? fire door ? x ?mm high including pressed steel frame for ? brick wall and preparing frame for door closer and lock

No

Not Priced

Class ? fire double door ? x ?mm high including pressed steel frame for ? brick wall and preparing frame for door closers

No

Not Priced

Class ? fire double door ? x ?mm high, each leaf with ? x ?mm opening with clear fire rated glass, including pressed steel frame for ? brick wall and preparing frame for door closers

No

Not Priced

5030

5031

5032

"?" folding doors including sliding gear, ironmongery, etc

5033

Single door for opening ? x ?mm high fixed to timber

No

Not Priced

5034

Single door for opening ? x ?mm high fixed to brickwork or concrete

No

Not Priced

5035

Double door for opening ? x ?mm high fixed to timber

No

Not Priced

5036

Double door for opening ? x ?mm high fixed to brickwork or concrete

No

Not Priced

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-162-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5037

"?" wrought ? horizontal slatted spring balanced tip-up garage doors including ironmongery etc

5038

Door for opening ? x ?mm high fixed to brickwork or concrete

R

Not Priced

No

Not Priced

No

Not Priced

5039

WINDOWS

5040

Wrought ? windows

5041

"?" wrought ? windows

5042

Window type ? ? x ?mm high

5043

FRAMED FRAMES ETC

5044

Wrought softwood

5045

Wrought meranti

5046

Wrought ?

5047

? x ?mm Linings

m

Not Priced

5048

? x ?mm Linings, plugged

m

Not Priced

5049

? x ?mm Rebated linings

m

Not Priced

5050

? x ?mm Rebated linings, plugged

m

Not Priced

5051

? x ?mm Frames

m

Not Priced

5052

? x ?mm Frames, plugged

m

Not Priced

5053

? x ?mm Frames, bolted

m

Not Priced

5054

? x ?mm Rebated frames

m

Not Priced

5055

? x ?mm Rebated frames, plugged

m

Not Priced

5056

? x ?mm Rebated frames, bolted

m

Not Priced

5057

? x ?mm Rebated and splayed frames

m

Not Priced

5058

? x ?mm Rebated and splayed frames, plugged

m

Not Priced

5059

? x ?mm Rebated and splayed frames, bolted

m

Not Priced

5060

? x ?mm Twice rebated frames

m

Not Priced

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-163-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5061

? x ?mm Twice rebated frames, plugged

m

Not Priced

5062

? x ?mm Twice rebated frames, bolted

m

Not Priced

5063

? x ?mm Twice rebated and splayed frames

m

Not Priced

5064

? x ?mm Twice rebated and splayed frames, plugged

m

Not Priced

5065

? x ?mm Twice rebated and splayed frames, bolted

m

Not Priced

5066

? x ?mm Splay rebated, angle rounded and grooved window sills

m

Not Priced

5067

User note

5068

Alternate method of measurement

5069

? x ?mm Frames with one labour

m

Not Priced

5070

? x ?mm Frames with one labour, plugged

m

Not Priced

5071

? x ?mm Frames with one labour, bolted

m

Not Priced

5072

? x ?mm Frames with ? labours

m

Not Priced

5073

? x ?mm Frames with ? labours, plugged

m

Not Priced

5074

? x ?mm Frames with ? labours, bolted

m

Not Priced

5075

? x ?mm Window sills with ? labours

m

Not Priced

5076

? x ?mm Window sills with ? labours, plugged

m

Not Priced

5077

? x ?mm Frame with one labour for ? x ?mm high door

No

Not Priced

5078

? x ?mm Frame with ? labours for ? x ?mm high door

No

Not Priced

5079

BEADS, ARCHITRAVES, ETC

5080

Wrought softwood

5081

Wrought meranti

5082

Wrought ?

5083

? x ?mm Grounds

m

Not Priced

5084

? x ?mm Grounds, nailed

m

Not Priced

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-164-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5085

? x ?mm Grounds, plugged

m

Not Priced

5086

? x ?mm Glazing beads

m

Not Priced

5087

? x ?mm Splayed glazing beads

m

Not Priced

5088

? x ?mm Twice angle rounded glazing beads

m

Not Priced

5089

? x ?mm Beads

m

Not Priced

5090

?mm Quadrant beads

m

Not Priced

5091

?mm Half round beads

m

Not Priced

5092

? x ?mm Architraves

m

Not Priced

5093

? x ?mm Architraves, plugged

m

Not Priced

5094

? x ?mm Splayed and angle rounded architraves

m

Not Priced

5095

? x ?mm Splayed and angle rounded architraves, plugged

m

Not Priced

5096

? x ?mm Moulded architraves

m

Not Priced

5097

? x ?mm Moulded architraves, plugged

m

Not Priced

5098

? x ?mm Rebated, splayed and grooved weather boards fixed in and including grooves in doors

m

Not Priced

5099

? x ?mm Rebated stiles, bolted

m

Not Priced

5100

? x ?mm Window sills

m

Not Priced

5101

? x ?mm Window sills, plugged

m

Not Priced

5102

? x ?mm Window sills with ? labours

m

Not Priced

5103

? x ?mm Window sills with ? labours, plugged

m

Not Priced

5104

STAIRS ETC

5105

Two 1,2m wide stairs from ground floor to first floor, each with one intermediate landing, in duplex flats

5106

Wrought ?

5107

Landings of ?mm tongued and grooved boarding in ?mm widths



Not Priced

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-165-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5108

Circular cutting

m

Not Priced

5109

? x ?mm Cleats

m

Not Priced

5110

? x ?mm Risers with rebated top edge let into and including groove in treads

m

Not Priced

? x ?mm Treads with half round front edge including blocking pieces

m

Not Priced

5111

5112

Housed end of tread to stringer

No

Not Priced

5113

Half round end to ?mm wide tread

No

Not Priced

5114

? x ?mm Stringers

m

Not Priced

5115

? x ?mm Stringers, bolted

m

Not Priced

5116

? x ?mm Bottom rails to balustrades

m

Not Priced

5117

? x ?mm Four times angle rounded bottom rails to balustrades

m

Not Priced

? x ?mm Four times angle rounded continuous handrails with dowelled heading joints

m

Not Priced

5118

5119

Extra over ? for rounded end

No

Not Priced

5120

Extra over ? for scrolled end

No

Not Priced

5121

Extra over ? for ramp or knee

No

Not Priced

5122

Extra over ? for bend

No

Not Priced

5123

Extra over ? for wreathed ramp

No

Not Priced

5124

Extra over ? for double wreathed ramp ?mm wide overall on plan

No

Not Priced

5125

Extra over for framing end of ? horizontal rail into newel

No

Not Priced

5126

Extra over for framing end of ? raking rail into newel

No

Not Priced

5127

? x ?mm Baluster ?mm long with bottom end framed into bottom rail and top end framed into handrail

No

Not Priced

? x ?mm Baluster ?mm long with bottom end framed into raking bottom rail and top end framed into raking handrail

No

Not Priced

5128

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-166-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5129

5130

R

Not Priced

? x ?mm Newel ?mm long with bottom end framed into stringer and top end moulded for a length of ?mm

No

Not Priced

? x ?mm Newel ?mm long with bottom end framed into raking stringer and top end moulded for a length of ?mm

No

Not Priced

5131

PANELLING ETC

5132

Sawn softwood

5133

Wrought softwood

5134

? x ?mm Grounds

m

Not Priced

5135

? x ?mm Grounds, nailed

m

Not Priced

5136

? x ?mm Grounds, plugged

m

Not Priced

5137

? x ?mm Grounds wrought on one face, plugged

m

Not Priced

5138

? x ?mm Bearers

m

Not Priced

5139

? x ?mm Bearers, nailed

m

Not Priced

5140

Wrought ?

5141

?mm Slatted panelling of ? x ?mm horizontal (vertical?) slats at ?mm centres (grounds elsewhere)



Not Priced

?mm Framed panelling ?mm high of ?mm wide framing and ?mm raised and fielded panels generally ?mm wide - three panels to the height



Not Priced

5142

5143

? x ?mm Beads

m

Not Priced

5144

? x ?mm Cover strips

m

Not Priced

5145

? x ?mm Edge strips

m

Not Priced

5146

? x ?mm Skirtings

m

Not Priced

5147

? x ?mm Rebated and moulded skirtings

m

Not Priced

5148

? x ?mm Cappings

m

Not Priced

5149

Interior type particle board with ? veneer

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-167-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5150

Interior type particle board with matched ? veneer

5151

?mm Flush panelling (grounds and cover strips elsewhere)



Not Priced

5152

?mm Flush panelling fixed to and including ? x ?mm wrought ? horizontal grounds at ?mm centres, plugged (cover strips elsewhere)



Not Priced

5153

Interior type particle board with ? veneer and veneered edges at open vertical joints

5154

?mm Flush panelling generally in ?mm widths with ?mm wide open vertical joints (grounds elsewhere)



Not Priced

?mm Flush panelling generally in ?mm widths with ?mm wide open vertical joints, fixed to and including ? x ?mm wrought ? horizontal grounds at ?mm centres, plugged



Not Priced



Not Priced

5155

5156

Non-combustible fibreglass sound insulation

5157

20mm Insulation felt (boards? mattresses?) of 24kg/m3 density fixed to walls between grounds behind panelling

5158

Linings, backings, etc

5159

Natural (Dyed?) moth-proof hessian stretched taut and stapled to timber



Not Priced

Fibreglass mosquito gauze stretched taut and stapled to timber



Not Priced

Galvanised steel mosquito gauze stretched taut and stapled to timber



Not Priced

5162

Copper mosquito gauze stretched taut and stapled to timber



Not Priced

5163

12mm Mesh galvanised chicken wire stretched taut and stapled to timber



Not Priced

5160

5161

5164

DUCT COVERS

5165

Sawn softwood

5166

Wrought softwood

5167

Wrought meranti

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-168-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5168

Wrought ?

5169

? x ?mm Grounds, nailed

m

Not Priced

5170

? x ?mm Grounds, plugged

m

Not Priced

5171

? x ?mm Framed frames

m

Not Priced

5172

? x ?mm Framed frames, plugged

m

Not Priced

5173

? x ?mm Framed frames, bolted

m

Not Priced

5174

? x ?mm Rebated and framed frames

m

Not Priced

5175

? x ?mm Rebated and framed frames, plugged

m

Not Priced

5176

? x ?mm Rebated and framed frames, bolted

m

Not Priced

5177

Standard hardboard

5178

Tempered hardboard

5179

Interior type particle board with ? veneer

5180

User note

5181

In order to make more accurate allowances for screws and waste, linear items are preferable

5182

?mm Duct covers in ?mm widths, fixed at ?mm centres along edges with chromium plated dome headed screws in cup washers



Not Priced

m

Not Priced

No

Not Priced



Not Priced

5183

5184

?mm Duct covers ?mm wide, fixed at ?mm centres along edges with chromium plated dome headed screws in cup washers ?mm Duct cover ? x ?mm high fixed at ?mm centres along edges with chromium plated dome headed screws in cup washers

5185

Fibre-cement medium (high?) density plain (textured?) flat sheets

5186

?mm Duct covers in ?mm widths, fixed at 450mm centres along edges with brass dome headed screws in cup washers

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-169-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5187

?mm Duct covers ?mm wide, fixed at 450mm centres along edges with brass dome headed screws in cup washers

R

Not Priced

m

Not Priced

5188

JOINERY SUNDRIES

5189

Wrought softwood

5190

Wrought meranti

5191

Wrought ?

5192

Slatted shelving, seats, etc of ? x ?mm wide slats at ?mm centres



Not Priced

Slatted shelving, seats, etc of ? x ?mm wide slats at ?mm centres, screwed to steel framing including holes



Not Priced

5193

5194

Raking cutting

m

Not Priced

5195

? x ?mm Bearers, nailed

m

Not Priced

5196

? x ?mm Bearers, plugged

m

Not Priced

5197

? x ?mm Bearers, bolted

m

Not Priced

5198

? x ?mm Twice angle rounded chair rails, plugged

m

Not Priced

5199

? x ?mm Rebated and moulded picture rails, plugged

m

Not Priced

5200

? x ?mm Cappings, plugged

m

Not Priced

5201

? x ?mm Hat and coat rails, nailed

m

Not Priced

5202

? x ?mm Hat and coat rails, plugged

m

Not Priced

5203

? x ?mm Twice angle rounded handrails

m

Not Priced

5204

? x ?mm Grooved and twice angle rounded handrails

m

Not Priced

5205

?mm Mopstick handrails

m

Not Priced

5206

NOTICEBOARDS, KEYBOARDS, DUCKBOARDS, ETC

5207

Wrought softwood

5208

Wrought meranti

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-170-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5209

Wrought ?

5210

? x ?mm Grounds, nailed

m

Not Priced

5211

? x ?mm Grounds, plugged

m

Not Priced

5212

? x ?mm Rebated surrounds, plugged

m

Not Priced

5213

? x ?mm Twice rebated surrounds, plugged

m

Not Priced

5214

? x ?mm Rebated and moulded surrounds

m

Not Priced

5215

? x ?mm Rebated and moulded surrounds, plugged

m

Not Priced

5216

? x ?mm Rebated and framed frames

m

Not Priced

5217

? x ?mm Duckboard of ? x ?mm slats on flat at ?mm centres and two (three?) ? x ?mm cross bearers

No

Not Priced



Not Priced

5218

Softboard

5219

12mm Pinning boards glued to plastered walls

5220

Interior type particle board

5221

?mm Backboards



Not Priced

5222

?mm Backboards plugged



Not Priced

5223

Foam backed polypropylene pinning boards

5224

?mm Pinning boards glued to backboards



Not Priced

5225

?mm Pinning boards glued to plastered walls



Not Priced

5226

?mm Pinning board ? x ?mm high glued to backboard

No

Not Priced

5227

?mm Pinning board ? x ?mm high glued to plastered walls

No

Not Priced

5228

FITTINGS

5229

TEN CUPBOARDS IN CLASSROOMS

5230

Sawn softwood

5231

Wrought softwood

5232

Wrought meranti

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-171-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5233

Wrought ?

5234

?mm Tops, shelves, sides, divisions, etc



Not Priced

5235

?mm Tops, shelves, sides, divisions, etc exceeding 300mm wide



Not Priced

5236

Raking cutting

m

Not Priced

5237

Circular cutting

m

Not Priced

5238

? x ?mm Cleats

m

Not Priced

5239

? x ?mm Bearers

m

Not Priced

5240

? x ?mm Bearers, nailed

m

Not Priced

5241

? x ?mm Bearers, plugged

m

Not Priced

5242

? x ?mm Skirtings

m

Not Priced

5243

? x ?mm Edge strips

m

Not Priced

5244

? x ?mm Twice angle rounded edge strips

m

Not Priced

5245

? x ?mm Framed framing

m

Not Priced

5246

? x ?mm Framed framing, plugged

m

Not Priced

5247

Drawer ? x ? x ?mm deep, of ? x ?mm grooved front, ? x ?mm grooved sides, ? x ?mm back and 3mm tempered hardboard bottom

No

Not Priced

?mm Sash door ? x ?mm high, of ?mm wide framing, in single pane, rebated all round including ? x ?mm glazing beads on one side

No

Not Priced

5248

5249

Standard hardboard

5250

Tempered hardboard

5251

Interior type particle board with ? veneer on one (both?) side(s)

5252

"?" particle board with ? veneer on one (both?) side(s)

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-172-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5253

Water resistant particle board with ?mm decorative thermosetting plastic laminate on one side and balancing plastic laminate on other side

5254

?mm Backboards



Not Priced

5255

?mm Tops, shelves, sides, divisions, etc



Not Priced

5256

?mm Adjustable shelving



Not Priced

5257

Raking cutting

m

Not Priced

5258

Circular cutting

m

Not Priced

5259

Thermosetting plastic laminate edge strips ?mm wide

m

Not Priced

5260

?mm Cupboard door ? x ?mm high with decorative thermosetting plastic laminate edge strips all round

No

Not Priced

?mm Double cupboard door ? x ?mm high with rebated (flush?) meeting edges, each leaf with decorative thermosetting plastic laminate edge strips all round

No

Not Priced



Not Priced

5261

5262

Decorative thermosetting plastic laminate

5263

"?" decorative plastic laminate

5264

?mm Covering to tops, shelves, sides, divisions, etc

5265

Raking cutting

m

Not Priced

5266

Circular cutting

m

Not Priced

5267

?mm Edge strips ?mm wide

m

Not Priced

5268

CUPBOARDS TO KITCHENS, BEDROOMS, ETC

5269

User note

5270

When using the following system of measuring cupboard fittings a detailed specification must either be annexed to the detail drawings of the cupboards or given in the bills of quantities

5271

The following clause is to be amended if any or all the items of others trades, i.e. glass, ironmongery, metalwork, paint or varnish finishes are given separately and is to include a clear statement to this effect

Carried forward Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-173-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5272

SUPPLEMENTARY PREAMBLES

5273

General

5274

The following cupboard fittings have been given as complete units i.e. the components of the units have not been given separately. Descriptions of such units shall, therefore, be deemed to include all components, assembling, housing, notching, glueing, blocking, planting-on and screwing with countersunk screws, edge strips, thermosetting plastic laminate, glass, ironmongery, metalwork, paint or varnish finishes, etc

R

Not Priced

Prices are to include for all necessary filler pieces against walls etc 5275

References

5276

References given in descriptions refer to the respective types of fittings detailed on the architect's drawing(s) numbered ? annexed to these bills of quantities (accompanying these bills of quantities?) for tender purposes

5277

Kitchen cupboards etc

5278

Kitchen cupboards etc with type ? hinges, type ? handles and type ? telescopic drawer slides

5279

Wall cupboard type ? ? x ?mm high with top, sides, bottom, division, shelf, back and ? single (double?) hinged door(s)

No

Not Priced

Floor cupboard type ? ? x ?mm high with top, sides, bottom, division, shelf, back and ? single (double?) hinged door(s?), dividing framework and ? drawers

No

Not Priced

Sink cupboard type ? ? x ?mm high with sides, bottom, divisions, shelf, back and ? single (double?) hinged door(s?) (sink elsewhere)

No

Not Priced

No

Not Priced

5280

5281

5282

Bedroom cupboards etc

5283

Bedroom cupboards etc with type ? hinges, type ? handles, type ? roller catches to upper doors, type ? cupboard locks to lower doors, 100mm brass barrel bolts to lower double doors and clothes hanging rails in hanging spaces

5284

Cupboard type ? ? x ? x ?mm high with top, sides, bottom, division, shelves, doors, etc

Carried to summary Bill No 11 Carpentry and Joinery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-174-

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

5285

BILL NO ?

5286

CEILINGS, PARTITIONS AND ACCESS FLOORING

5287

SUPPLEMENTARY PREAMBLES

5288

Fixing

5289

Items described as "nailed" shall be deemed to be fixed with hardened steel nails or pins, or to be shot-pinned, to brickwork or concrete

5290

Items described as "plugged" shall be deemed to include screwing to fibre, plastic or metal plugs at not exceeding 500mm centres, and where described as "bolted", the bolts have been given elsewhere

5291

Ceilings

5292

Unless otherwise described ceilings shall be deemed to be horizontal

5293

Bulkheads

5294

Bulkheads are defined as those portions of ceilings which are stepped down from the general ceiling level in a particular room or area and which generally occur along the perimeter. Their purpose is either to conceal services or to create architectural features

5295

Bulkheads have only been described as such where they conform to the above definition and where the horizontal or vertical dimensions do not exceed 900mm. Where these dimensions are more than 900mm such portions of ceilings have been included in the appropriate general items of ceilings

5296

Unless otherwise described bulkheads shall be deemed to be horizontal along the length

5297

Steel components

5298

All steel components for ceilings, partitions, etc are to be galvanised in accordance with SANS 121

5299

User note

5300

Circular bulkheads shall be given separately

Carried forward Bill No 12 Ceilings, Partitions and Access Flooring ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-175-

Quantity

Rate

Amount

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5301

CEILING TIMBERS, BEADS, INSULATION, ETC

5302

Sawn softwood

5303

Wrought softwood

5304

Wrought meranti

5305

Wrought ?

5306

User note

5307

The first four of the following items are applicable only when the brandering, due to irregularity etc thereof, can not be included with the ceilings

5308

? x ?mm Branders

m

Not Priced

5309

? x ?mm Branders, nailed

m

Not Priced

5310

? x ?mm Branders, plugged

m

Not Priced

5311

? x ?mm Branders wrought on one face, plugged

m

Not Priced

5312

? x ?mm Ceiling joists

m

Not Priced

5313

? x ?mm Runners

m

Not Priced

5314

? x ?mm Hangers

m

Not Priced

5315

?mm Quadrant beads

m

Not Priced

5316

? x ?mm Beads

m

Not Priced

5317

? x ?mm Cornices, nailed

m

Not Priced

5318

? x ?mm Cornices, plugged

m

Not Priced

5319

? x ?mm Splayed cornices, nailed

m

Not Priced

5320

? x ?mm Splayed cornices, plugged

m

Not Priced

5321

? x ?mm Rebated cornices, nailed

m

Not Priced

5322

? x ?mm Rebated cornices, plugged

m

Not Priced

5323

? x ?mm Moulded cornices, nailed

m

Not Priced

5324

? x ?mm Moulded cornices, plugged

m

Not Priced

Carried forward Bill No 12 Ceilings, Partitions and Access Flooring ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-176-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5325

Non-combustible fibreglass insulation of a density of not less than 10kg/m3 bonded with an inert thermo-setting resin

5326

"?" insulation

5327

?mm Insulation in blanket form closely fitted and laid on top of brandering between roof timbers etc



Not Priced

?mm Insulation in blanket form lapped not less than 50mm along all edges and laid on top of brandering between roof timbers etc



Not Priced

5328

5329

NAILED-UP CEILINGS

5330

SUPPLEMENTARY PREAMBLES

5331

Openings

5332

Prices for openings for light fittings, ventilation grilles, air conditioning diffusers, etc are to include for any necessary additional support, trimming around, etc

5333

6,4mm Gypsum plasterboard

5334

6,4mm Gypsum plasterboard with galvanised steel (plastic? "Aluzinc"? "Chromaprep"? "Rhino M-strips"?) jointing strips

5335

6,4mm Gypsum plasterboard with H-profile galvanised steel (PVC?) jointing strips

5336

6,4mm Gypsum plasterboard with 6 x 50mm fibre cement cover strips over joints

5337

6,4mm Gypsum plasterboard with ?mm wrought softwood half round cover strips over joints

5338

9,5mm (12,5mm?) Taper-edge gypsum plasterboard with taped and skimmed flush joints

5339

6,4mm Gypsum plasterboard with taped joints and the whole finished with gypsum plaster trowelled to a smooth polished surface to the thickness recommended by the manufacturer

5340

9,5mm Taper-edge gypsum plasterboard with taped joints and the whole finished with gypsum plaster trowelled to a smooth polished surface to the thickness recommended by the manufacturer

Carried forward Bill No 12 Ceilings, Partitions and Access Flooring ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-177-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5341

4,6mm Fibre-cement plain ceiling boards

5342

4,6mm Fibre-cement plain ceiling boards with ? x ?mm cover strips over joints

5343

4,6mm Fibre-cement plain ceiling boards with H-profile galvanised steel (PVC?) jointing strips

5344

Ceilings including standard steel brandering at ?mm centres in one direction only, joined with joiner sections and hung with suspension brackets including standard steel perimeter angles fixed to walls etc



Not Priced

Sloping ceilings including standard steel brandering at ?mm centres in one direction only, joined with joiner sections and hung with suspension brackets including standard steel perimeter angles fixed to walls etc



Not Priced

Vertical ceilings including standard steel brandering at ?mm centres in one direction only, joined with joiner sections and hung with suspension brackets



Not Priced

Ceilings including ? x ?mm sawn softwood brandering at ?mm centres and cross brandering at ?mm centres



Not Priced

Sloping ceilings including ? x ?mm sawn softwood brandering at ?mm centres and cross brandering at ?mm centres



Not Priced

Vertical ceilings including ? x ?mm sawn softwood brandering at ?mm centres and cross brandering at ?mm centres



Not Priced

Ceilings including ? x ?mm sawn softwood brandering at ?mm centres generally in one direction and ? x ?mm branders and cross branders at joints and edges of boards



Not Priced

Sloping ceilings including ? x ?mm sawn softwood brandering at ?mm centres generally in one direction and ? x ?mm branders and cross branders at joints and edges of boards



Not Priced

Vertical ceilings including ? x ?mm sawn softwood brandering at ?mm centres generally in one direction and ? x ?mm branders and cross branders at joints and edges of boards



Not Priced

m

Not Priced

5345

5346

5347

5348

5349

5350

5351

5352

5353

Circular cutting

Carried forward Bill No 12 Ceilings, Partitions and Access Flooring ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-178-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5354

5355

5356

5357

5358

5359

5360

5361

5362

5363

5364

R

Not Priced

Horizontal portion of bulkhead ?mm wide including standard steel brandering at ?mm centres, joined with joiner sections and hung with suspension brackets (supporting framework elsewhere)

m

Not Priced

Vertical portion of bulkhead ?mm high including standard steel brandering at ?mm centres, joined with joiner sections and hung with suspension brackets (supporting framework elsewhere)

m

Not Priced

Sloping portion of bulkhead ?mm high (measured on slope) including standard steel brandering at ?mm centres, joined with joiner sections and hung with suspension brackets (supporting framework elsewhere)

m

Not Priced

Horizontal portion of bulkhead ?mm wide including ? x ?mm sawn softwood brandering at ?mm centres (supporting framework elsewhere)

m

Not Priced

Vertical portion of bulkhead ?mm high including ? x ?mm sawn softwood brandering at ?mm centres (supporting framework elsewhere)

m

Not Priced

Sloping portion of bulkhead ?mm high (measured on slope) including ? x ?mm sawn softwood brandering at ?mm centres (supporting framework elsewhere)

m

Not Priced

Rectangular bulkhead against wall, ?mm wide x ?mm high, including standard steel brandering at ?mm centres, joined with joiner sections and hung with suspension brackets (supporting framework elsewhere)

m

Not Priced

Rectangular bulkhead against wall, ?mm wide x ?mm high, including ? x ?mm sawn softwood brandering at ?mm centres (supporting framework elsewhere)

m

Not Priced

Bulkhead against wall with sloping front, ?mm wide on soffit x ?mm high (measured on slope), including standard steel brandering at ?mm centres, joined with joiner sections and hung with suspension brackets (supporting framework elsewhere)

m

Not Priced

Bulkhead against wall with sloping front, ?mm wide on soffit x ?mm high (measured on slope), including ? x ?mm sawn softwood brandering at ?mm centres (supporting framework elsewhere)

m

Not Priced

No

Not Priced

Opening for sprinkler head

Carried forward Bill No 12 Ceilings, Partitions and Access Flooring ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-179-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5365

Extra over ceiling for opening for ?mm diameter downlighter

No

Not Priced

5366

Extra over ceiling for opening for ? x ?mm light fitting

No

Not Priced

5367

Extra over ceiling for ? x ?mm opening for ventilation grille/air conditioning diffuser

No

Not Priced

Extra over ceiling for ? x ? x ?mm thick pressed steel trap door, hinged to open 180 degrees onto ceiling, in ? x ? x ?mm T-section steel frame

No

Not Priced

Extra over ceiling for ? x ?mm trap door of ? x ?mm wrought softwood rebated framing with one cross brander, covered with ceiling board and fitted flush in opening, including necessary trimmers around

No

Not Priced

5368

5369

5370

"?" pre-painted acoustic panels with bevelled edges

5371

Ceilings of ? x ? x ?mm panels including ? x ?mm sawn softwood brandering at ?mm centres in both directions



Not Priced

Ceilings of ? x ? x ?mm panels including ? x ?mm sawn softwood brandering at ?mm centres and cross brandering at ?mm centres



Not Priced

m

Not Priced

5372

5373

Circular cutting

5374

Gypsum plasterboard cornices

5375

?mm Coved cornices

m

Not Priced

5376

?mm Coved cornices, plugged

m

Not Priced

5377

? x ?mm Type ? moulded cornices

m

Not Priced

5378

? x ?mm Type ? polystyrene coved (moulded?) cornices

m

Not Priced

5379

? x ?mm Type ? polyurethane coved (moulded?) cornices

m

Not Priced

5380

SUSPENDED CEILINGS

5381

SUPPLEMENTARY PREAMBLES

5382

Proprietary suspended ceilings

5383

Hangers, suspension grids, "lay-in" panels, etc are to be in accordance with the manufacturers' recommendations

Carried forward Bill No 12 Ceilings, Partitions and Access Flooring ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-180-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5384

User note

5385

The following preamble to be included in the bills of quantities after confirmation of the basic design of the ceilings, lighting, air conditioning, etc

5386

Electrical light fittings, diffusers, panels etc are generally "lay-in" units of the same dimensions as the suspension grid described and allowance must be made in the rates accordingly for their support inclusive of any flexibility in setting out that may be required (ceiling panels have not been deducted and pricing is to take cognisance thereof)

5387

Flush plastered gypsum plasterboard suspended ceilings

5388

Ceilings shall comprise 6,4mm (9,5mm? 12,5mm?) gypsum plasterboard boards screwed to and including screw-up suspension grid consisting of main tees at 1 200mm centres and galvanised steel capped cross tees at 400mm centres and with tape fixed over joints and the whole finished with gypsum plaster trowelled to a smooth polished surface

5389

The grid shall be suspended by means of galvanised steel L-section hangers at suitable centres, securely shot-pinned or screwed to concrete, steel or wood

5390

Flush plastered gypsum plasterboard suspended bulkheads

5391

Bulkheads shall comprise galvanised steel studding of 63,5mm top and bottom tracks with vertical studs at maximum 400mm centres, pop-riveted to the top and bottom tracks with similar additional vertical studs as necessary at abutments, ends, etc and covered as described with plasterboard screwed to studding with drywall screws at maximum 300mm centres. Boards shall be butt jointed and finished with tape and jointing compound and the whole finished with gypsum plaster trowelled to a smooth polished surface to the thickness recommended by the manufacturer

5392

Descriptions shall be deemed to include any additional studs at ends and intersections, corner beads, cornices at junctions with ceilings, jointing compound, tape, etc

5393

? x ? x ?mm "?" pre-painted acoustic panels on exposed suspension grid system including hangers, necessary hold-down clips and wedges, etc

Carried forward Bill No 12 Ceilings, Partitions and Access Flooring ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-181-

R

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5394

? x ? x ?mm "?" pre-painted chamfered and grooved acoustic panels on concealed suspension grid including hangers etc

5395

?mm Gypsum plasterboard on screw-up tee suspension grid including hangers etc, with tape fixed over joints and the whole finished with gypsum plaster trowelled to a smooth polished surface

5396

Ceilings suspended not exceeding 1m (exceeding ?m and not exceeding ?m) below concrete soffits



Not Priced

Ceilings suspended not exceeding 1m (exceeding ?m and not exceeding ?m) below timber (steel?) purlins at ?mm centres (trusses at ?m centres)



Not Priced

Sloping ceilings suspended not exceeding 1m (exceeding ?m and not exceeding ?m) below concrete soffits



Not Priced

Sloping ceilings suspended not exceeding 1m (exceeding ?m and not exceeding ?m) below timber (steel?) purlins at ?mm centres (trusses at ?m centres)



Not Priced

Vertical ceilings suspended not exceeding 1m (exceeding ?m and not exceeding ?m) below concrete soffits



Not Priced

Vertical ceilings suspended not exceeding 1m (exceeding ?m and not exceeding ?m) below timber (steel?) purlins at ?mm centres (trusses at ?m centres)



Not Priced

5397

5398

5399

5400

5401

5402

Circular cutting

m

Not Priced

5403

Margins ?mm (exceeding ?mm and not exceeding ?mm) wide around lay-in panel ceilings, suspended not exceeding 1m (exceeding ?m and not exceeding ?m) below concrete soffits

m

Not Priced

Horizontal portion of bulkheads ?mm wide, suspended not exceeding 1m (exceeding ?m and not exceeding ?m) below concrete soffits

m

Not Priced

Vertical portion of bulkheads ?mm high, suspended not exceeding 1m (exceeding ?m and not exceeding ?m) below concrete soffits

m

Not Priced

Sloping portion of bulkheads ?mm high (measured on slope), suspended not exceeding 1m (exceeding ?m and not exceeding ?m) below concrete soffits

m

Not Priced

5404

5405

5406

Carried forward Bill No 12 Ceilings, Partitions and Access Flooring ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-182-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5407

5408

5409

R

Not Priced

Rectangular bulkheads against wall ?mm wide x ?mm high, suspended not exceeding 1m (exceeding ?m and not exceeding ?m) below concrete soffits

m

Not Priced

Intermediate rectangular bulkheads ?mm wide x ?mm high, suspended not exceeding 1m (exceeding ?m and not exceeding ?m) below concrete soffits

m

Not Priced

Intermediate rectangular bulkheads ?mm wide x ?mm high on one side and ?mm high on other side, suspended not exceeding 1m (exceeding ?m and not exceeding ?m) below concrete soffits

m

Not Priced

5410

Opening for sprinkler head

No

Not Priced

5411

Extra over ceiling for opening for ?mm diameter downlighter

No

Not Priced

5412

Extra over ceiling for opening for ? x ?mm light fitting

No

Not Priced

5413

Extra over ceiling for ? x ?mm opening for ventilation grille/air conditioning diffuser

No

Not Priced

5414

"?" cornices, perimeter trims, etc to suspended ceilings

5415

Type ? pre-painted wall angles, plugged

m

Not Priced

5416

Type ? pre-painted wall channels, plugged

m

Not Priced

5417

Type ? pre-painted recessed wall angles, plugged

m

Not Priced

5418

Type ? pre-painted cornices, plugged

m

Not Priced

5419

Type ? pre-painted cornices for flush plastered ceilings, plugged

m

Not Priced

5420

PARTITIONS ETC

5421

User note

5422

Selected examples of typical preambles and items with trade names are provided to show possible ways of describing such items. Users must adapt these examples to suit their particular circumstances

5423

FIXED PARTITIONS

5424

SUPPLEMENTARY PREAMBLES

Carried forward Bill No 12 Ceilings, Partitions and Access Flooring ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-183-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5425

"GypRoc Drywall" partition systems

5426

Partitions consisting of 63,5mm (51mm? 104mm?) "Ultra Drywall" steel studs inserted at 600mm centres into 63,5mm (51mm? 104mm?) "Ultrasteel Drywall" steel track at top and bottom clad on both sides as described, including additional studs as necessary at abutments, ends, etc. Boards shall be fixed in strict accordance with the manufacturer's instructions and all joints shall be taped and jointed

5427

Unless otherwise described rates for partitions shall be deemed to include for standard flat section aluminium skirtings on both sides

5428

Wall paper and/or paint and varnish finishes are given elsewhere

5429

"GypRoc Standard System" steel stud partitions with both sides clad with one layer of 12,5mm "Taper-edge Rhinoboard"

5430

"GypRoc Silent System" steel stud partitions with both sides clad with one layer of 12,5mm "Taper-edge Rhino Firestop Board" and with "Rhino Flam" mineral fibre blanket inserted in cavity

5431

"GypRoc Tough System" steel stud partitions with both sides clad with two layers of 12,5mm "Taper-edge Rhinoboard"

5432

"GypRoc Silent 52 System" steel stud partitions with both sides clad with two layers of 12,5mm "Taper-edge Rhino Firestop Board" and with "Rhino Flam" mineral fibre blanket inserted in cavity

5433

"GypRoc Secure System" steel stud partitions with both sides clad with two layers of 12,5mm "Taper-edge Rhino Firestop Board" with 0,5mm galvanised steel sheet sandwiched between

5434

"GypRoc Firebreak System" steel stud partitions with both sides clad with one layer of 12,5mm "Taper-edge Rhino Firestop Board" and one layer of 15mm "Taper-edge Rhino Firestop Board"

5435

Partitions ?m high with bottom and top tracks plugged

m

Not Priced

5436

Partitions ?m high with bottom track plugged and top track fixed to suspended ceiling tees

m

Not Priced

Carried forward Bill No 12 Ceilings, Partitions and Access Flooring ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-184-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5437

Partitions ?m high with top and bottom tracks plugged, with lower section solid ?m high and upper section ?m high framed all round with "Drywall" mill finished (natural?) anodised aluminium glazing sections and divided into panels with aluminium mullions at ?m centres, with each panel glazed with ?mm clear float glass including neoprene glazing gaskets

R

Not Priced

m

Not Priced

5438

Extra over partition ?m high for vertical abutment

No

Not Priced

5439

Extra over partition ?m high for corner

No

Not Priced

5440

Extra over partition ?m high for irregular corner

No

Not Priced

5441

Extra over partition ?m high for T-intersection

No

Not Priced

5442

Extra over partition ?m high for fair end

No

Not Priced

5443

Extra over "?" partitions for 40mm semi-solid flush doors with ? veneer on both sides and hardwood edge strips to vertical edges, hung to and including standard pressed steel door frame with one pair of 100mm steel hinges to each hanging stile, including additional studding, trimming, etc. to partitions

5444

Extra over "?" partitions for 40mm semi-solid flush doors with ? veneer on both sides and hardwood edge strips to vertical edges, hung to and including standard natural anodised aluminium door frame with one pair of 100mm nylon washered aluminium hinges to each hanging stile, including additional studding, trimming, etc. to partitions

5445

User note

5446

Barrel bolts, locksets, etc may be given separately

5447

Door ? x ?mm high including "?" lockset

No

Not Priced

5448

Door ? x ?mm high with ? x ?mm opening for louvre unit including "?" lockset

No

Not Priced

Double door ? x ?mm high including two "?" barrel bolts and "?" lockset

No

Not Priced

Double door ? x ?mm high with ? x ?mm opening for louvre unit per leaf including two "?" barrel bolts and "?" lockset

No

Not Priced

5449

5450

5451

DEMOUNTABLE PARTITIONS

Carried forward Bill No 12 Ceilings, Partitions and Access Flooring ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-185-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5452

SUPPLEMENTARY PREAMBLES

5453

"GypRoc Vanguard" demountable partition system

5454

Partitions consisting of galvanised steel ceiling, wall and floor tracks and vertical studs and 12,5mm "Rhinoboard" bevel-edged panels clad on both sides as described, retained in position with metal spring clips, including (natural?) anodised aluminium exposed trims, flat section (ribbed?) skirtings, etc

5455

"GypRoc Crusader" demountable partition system

5456

Partitions consisting of galvanised steel ceiling, wall and floor tracks and vertical studs and 12,5mm "Rhinoboard" square-edged panels clad on both sides as described, retained in position with battens clipped into studs, including (natural?) anodised aluminium trims, flat section (ribbed?) skirtings, etc

5457

"GypRoc Steel Faced Crusader" demountable partition system

5458

Partitions consisting of galvanised steel ceiling, wall and floor tracks and vertical studs and 12,5mm "Rhinoboard" square-edged panels clad on both sides as described, retained in position with battens clipped into studs, including (natural?) anodised aluminium trims, flat section (ribbed?) skirtings, etc

5459

"GypRoc Vanguard" demountable partition system with both sides clad with "?" paper-backed vinyl covering of a module width of 600mm (750mm? 1200mm?)

5460

"GypRoc Crusader" demountable partition system with both sides clad with "?" paper-backed vinyl covering of a module width of 911mm (1211mm?)

5461

"GypRoc Steel Faced Crusader" demountable partition system with both sides clad with "?" "Chromadek" polyester painted steel (stainless steel? galvanised steel with "?" paper-backed vinyl?) covering of a module width of 600mm (750mm? 900mm?)

5462

Partitions ?m high with bottom and top tracks plugged

m

Not Priced

5463

Partitions ?m high with bottom track plugged and top track fixed to suspended ceiling tees

m

Not Priced

Carried forward Bill No 12 Ceilings, Partitions and Access Flooring ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-186-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5464

Partitions ?m high with bottom and top tracks plugged, with lower section solid ?m high and upper section ?m high glazed with ?mm clear float glass

R

Not Priced

m

Not Priced

5465

Extra over partition ?m high for vertical abutment

No

Not Priced

5466

Extra over partition ?m high for corner

No

Not Priced

5467

Extra over partition ?m high for irregular corner

No

Not Priced

5468

Extra over partition ?m high for T-intersection

No

Not Priced

5469

Extra over partition ?m high for T-intersection of solid with half-glazed partition

No

Not Priced

5470

Extra over partition ?m high for fair end

No

Not Priced

5471

Extra over "?" partitions for 40mm semi-solid flush doors with ? veneer on both sides and hardwood edge strips to vertical edges, hung to and including standard natural anodised aluminium door frame with one pair of 100mm nylon washered aluminium hinges to each hanging stile, including additional studding, trimming, etc to partitions

5472

Door ? x ?mm high including "?" lockset

No

Not Priced

5473

Door ? x ?mm high with ? x ?mm opening for louvre unit including "?" lockset

No

Not Priced

Double door ? x ?mm high including two "?" barrel bolts and "?" lockset

No

Not Priced

Double door ? x ?mm high including ? x ?mm opening for louvre unit per leaf, and two "?" barrel bolts and one "?" lockset

No

Not Priced



Not Priced

5474

5475

5476

Insulation

5477

?mm Thick "?" mineral fibre blanket in cavity of partitioning

5478

FIRE BARRIERS ABOVE CEILINGS

Carried forward Bill No 12 Ceilings, Partitions and Access Flooring ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-187-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5479

User note

5480

Fire barriers may be measured in square meters in which case sealing of laps, bottom and vertical abutments shall be measured separately

R

Not Priced

Fire barriers are generally constructed as described for drywall partitions 5481

SUPPLEMENTARY PREAMBLES

5482

Construction

5483

The type and thickness of boards, the number of layers and the insulation (if necessary) is to be such as to produce the specified fire rating all in accordance with the manufacturer's recommendation Top and bottom edges, abutments, openings, etc are to be sealed to maintain the fire rating specified

5484

Fire barriers above ceilings with half-hour (one-hour? two-hour? etc?) fire rating

5485

Barriers ?mm high between suspended ceiling and soffit of concrete slab

m

Not Priced

5486

Extra over for vertical abutment

No

Not Priced

5487

Extra over for L or T-intersection

No

Not Priced

5488

Extra over for filling into coffer of coffered slab, ?mm wide at bottom with sides splayed to ?mm wide at top x ?mm high

No

Not Priced

Cutting and fitting around not exceeding ?mm diameter pipe including sealing

No

Not Priced

Cutting and fitting around ? x ?mm air conditioning duct including sealing

No

Not Priced

5489

5490

5491

TOILET CUBICLES

Carried forward Bill No 12 Ceilings, Partitions and Access Flooring ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-188-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5492

"?" toilet cubicles consisting of 20mm thick partitions, doors and stiles of laminated construction with outer skins of vitreous enamelled steel sheets bonded to wood particle board, all framed in natural anodised aluminium channel section beading, top rails and fixing components and fitted with all necessary ironmongery comprising standard indicating bolts, combined coat hooks and door stops, toilet roll holders and rubber buffers

5493

Partition ? x 1800mm high

No

Not Priced

5494

Door ? x 1800mm high

No

Not Priced

5495

Full stile 210 x 2000mm high

No

Not Priced

5496

End stile 145 x 2000mm high

No

Not Priced

5497

Wall stile 105 x 2000mm high

No

Not Priced

5498

Extra over for chromium plated rising butt hinge

No

Not Priced

5499

Extra over for powder coating to aluminium beading, brackets and ironmongery - per cubicle

No

Not Priced



Not Priced

5500

ACCESS FLOORING

5501

User note

5502

When access flooring is to be included in the bills of quantities, other than by means of a provisional sum, supplementary preambles in the form of technical specifications and descriptions are to be compiled in conjunction with specialists in this field and thoroughly investigated and checked to ascertain their correctness for the works

5503

The following items are based on a particular manufacturer's system for a particular contract and must be used as a guide only

5504

"Donn Snap-Loc" Class ? access flooring

5505

600 x 600mm Modular and interchangeable "Solid feel 30" board panel access flooring including pedestals and panels finished with factory bonded 1,3mm thick plastic laminate (access flooring to finish 600mm above concrete sub-floor)

Carried forward Bill No 12 Ceilings, Partitions and Access Flooring ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-189-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5506

5507

R

Not Priced

? x ?mm Modular and interchangeable "Solid feel 30" board panel access flooring including stringers, pedestals and panels finished with "?" carpet tiles glued on with approved adhesive (access flooring to finish 600mm above concrete sub-floor)



Not Priced

? x ?mm Modular and interchangeable "Solid feel 30" board panel access flooring including stringers, pedestals and panels with cementitious filling, finished with factory bonded 1,3mm thick plastic laminate (access flooring to finish 600mm above concrete sub-floor)



Not Priced

5508

Junctions against walls and columns

m

Not Priced

5509

Junctions against circular walls and columns

m

Not Priced

5510

Hole for ?mm diameter pipe through floor panel including sealing

No

Not Priced

? x ?mm Opening through floor panel for air conditioning grille including sealing

No

Not Priced

5511

5512

Supplying, erecting, dismantling and removing from site ? x ? x ?mm high sample of class "?" access flooring (refer to clause "?" of access floor specification)

Item

Not Priced

5513

Sundries

5514

Vacuum cleaning the floor void after installation of services



Not Priced

5515

Fire barrier ?mm high between concrete sub-floor and floor panels (? hour fire rating)

m

Not Priced

Cutting and fitting fire barrier around ?mm diameter pipe including sealing

No

Not Priced

Cutting and fitting fire barrier around ? x ?mm metal duct including sealing

No

Not Priced

5518

Carpet panel lifting device

No

Not Priced

5519

Double suction-type panel lifting device

No

Not Priced

5520

Spare floor panel finished with factory bonded 1,3mm thick plastic laminate, handed to the employer

No

Not Priced

5516

5517

Carried to summary Bill No 12 Ceilings, Partitions and Access Flooring ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-190-

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

Quantity

Rate

Amount

5735

BILL NO ?

5736

FLOOR COVERINGS, WALL LININGS, ETC

5737

SUPPLEMENTARY PREAMBLES

5738

Fixing

5739

Floor coverings, wall linings, etc shall, where applicable, be fixed with adhesive as recommended by the manufacturers of the flooring, linings, etc

5740

FLOOR COVERINGS

5741

? x ? x ?mm Brown Zimbabwe teak (Mukusi) mosaic wood blocks in ? x ?mm sheets

5742

? x ? x ?mm Brown Zimbabwe teak (Mukusi) mosaic wood blocks in ? x ?mm sheets, to ? pattern

5743

?mm Type ? laminated timber and "Formica" finished tongued-and-grooved strip floors with cushion backing, in ?mm widths on and including polyethylene dampproof sheeting

5744

?mm ? (Beech? etc?) type ? prefinished tongued-and-grooved strip floors in ?mm widths

5745

On floors



Not Priced

5746

On treads and risers of stepped floors



Not Priced

5747

On treads and risers of stairs



Not Priced

5748

On treads and risers of winding stairs



Not Priced

5749

Circular cutting

m

Not Priced

5750

Margins and borders not exceeding 500mm wide

m

Not Priced

5751

? x ? x ?mm Type ? semi flexible vinyl tiles

5752

? x ? x ?mm Type ? fully flexible vinyl tiles

5753

? x ? x ?mm Type ? heavy duty vinyl tiles

5754

? x ? x ?mm Type ? electrostatic conductive vinyl tiles

5755

? x ? x ?mm Type ? electrostatic dissipative vinyl tiles

Carried forward Bill No 13 Floor Coverings, Wall Linings, etc ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-191-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5756

? x ? x ?mm Type ? woodplank vinyl tiles

5757

? x ? x ?mm Type ? rubber tiles

5758

?mm Type ? fully flexible sheeting with welded joints

5759

?mm Type ? flexible vinyl cork sheeting

5760

?mm Type ? linoleum sheeting with welded joints

5761

Type ? synthetic sports flooring

5762

Type ? multipurpose synthetic indoor sports flooring

5763

Type ? abrasion resistant flooring

5764

Type ? synthetic turf

5765

? x ?mm Type ? elastic safety tiles

5766

? x ?mm Type ? elastic safety pavers

5767

Type ? resin backed polypropylene needlepunch carpeting

5768

Type ? fibrebonded polypropylene carpeting

5769

Type ? cut pile carpeting including ?g/m² felt underlay

5770

Type ? loop pile carpeting including ?g/m² felt underlay

5771

? x ?mm Type ? fibrebonded polypropylene carpet tiles

5772

On floors



Not Priced

5773

On dished floors



Not Priced

5774

On treads and risers of stepped floors



Not Priced

5775

On treads and risers of stairs



Not Priced

5776

On treads and risers of winding stairs



Not Priced

5777

Circular cutting

m

Not Priced

5778

Margins and borders not exceeding 500mm wide

m

Not Priced

5779

Turn-ups over coves and up against walls not exceeding 500mm girth

m

Not Priced

Carried forward Bill No 13 Floor Coverings, Wall Linings, etc ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-192-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5780

Inserts ?mm wide of differing colour

m

Not Priced

5781

?mm Wide x ?mm high combined tread and riser covering

m

Not Priced

5782

WALL LININGS

5783

?mm Type ? fully flexible vinyl sheeting with welded joints

5784

?mm Type ? flexible vinyl cork sheeting

5785

Type ? resin backed polypropylene needlepunch carpeting

5786

Type ? cut pile carpeting

5787

Type ? loop pile carpeting

5788

Type ? resin backed polypropylene needlepunch carpeting secured to wooden framing including gripper strips etc

5789

Type ? cut pile carpeting secured to wooden framing including gripper strips etc

5790

Type ? loop pile carpeting secured to wooden framing including gripper strips etc

5791

On walls



Not Priced

5792

On circular walls



Not Priced

5793

Circular cutting

m

Not Priced

5794

SKIRTINGS, NOSINGS, ETC

5795

Type ? skirtings, nosings, etc

5796

?mm Code ? vinyl edging

m

Not Priced

5797

?mm Code ? vinyl edging stepped over treads and risers of stairs

m

Not Priced

5798

?mm Code ? vinyl skirtings

m

Not Priced

5799

?mm Code ? vinyl skirtings stepped over treads and risers of stairs

m

Not Priced

5800

?mm Code ? vinyl quarter rounds

m

Not Priced

5801

? x ?mm Code ? profiled vinyl skirtings

m

Not Priced

Carried forward Bill No 13 Floor Coverings, Wall Linings, etc ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-193-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5802

R

Not Priced

? x ?mm Code ? profiled vinyl skirtings stepped over treads and risers of stairs

m

Not Priced

5803

? x ?mm Code ? profiled vinyl chair rails

m

Not Priced

5804

?mm Code ? vinyl stair nosings

m

Not Priced

5805

?mm Code ? natural (colour?) anodised cover strips fixed to concrete

m

Not Priced

?mm Code ? natural (colour?) anodised aluminium nosings with PVC insets fixed to concrete

m

Not Priced

m

Not Priced

m

Not Priced

5806

5807

HANDRAILS

5808

Type ? handrails

5809

Code ? handrails fitted over ? x ?mm core rail

5810

WALL AND CORNER PROTECTORS

5811

Type ? wall and corner protectors

5812

Code ? wall protectors including code ? brackets

5813

Extra over for stopped end

No

Not Priced

5814

Extra over for corner

No

Not Priced

5815

POLISH, SEALERS, ETC

5816

? coats wax polish on vinyl flooring



Not Priced

Carried to summary Bill No 13 Floor Coverings, Wall Linings, etc ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-194-

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

1451

BILL NO ?

1452

IRONMONGERY

1453

SUPPLEMENTARY PREAMBLES

1454

Proprietary items

1455

Where applicable the manufacturers' names or product catalogue titles are given in sub-headings preceding the items

Quantity

Rate

Amount

Prices are to be based on the specific products/articles specified. If tenderers wish to offer alternative products/articles for certain items, these items are to be clearly marked and the alternative specification given with supporting brochures etc clarifying the features of the products/articles offered On request returnable samples are to be provided to the principal agent for consideration 1456

Finishes to ironmongery

1457

Where applicable finishes to ironmongery are indicated by suffixes in accordance with the following list: BS Satin bronze lacquered CH Chromium plated SC Satin chromium plated SE Silver enamelled GE Grey enamelled AN Anodised natural AS Anodised silver AB Anodised bronze AG Anodised gold ABL Anodised black PB Polished brass PL Polished and lacquered PT Epoxy coated SD Sanded

1458

HINGES, BOLTS, ETC

1459

Manufactured by "?"

1460

In accordance with "?" catalogue

1461

?mm (Open) chromium plated (brass plated?) piano hinges

m

Not Priced

1462

?mm (Open) brass piano hinges

m

Not Priced

Carried forward Bill No 14 Ironmongery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-195-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1463

?mm Steel (brass?) hinge

No

Not Priced

1464

?mm Steel rising hinge

No

Not Priced

1465

?mm Aluminium (brass?) hinge with stainless steel washers

No

Not Priced

1466

?mm Brass hinge with nylon washers

No

Not Priced

1467

?mm Ball bearing brass hinge

No

Not Priced

1468

? x ?mm Brass parliament hinge

No

Not Priced

1469

"Ref ?" satin chromium plated (brass?) single action floor spring hinge with (without?) stand open feature, including adjustable top centre and with box let into concrete

No

Not Priced

"Ref ?" satin chromium plated (brass?) double action floor spring hinge with (without?) stand open feature, including adjustable top centre and with box let into concrete

No

Not Priced

1471

?mm Chromium plated (brass?) barrel bolt

No

Not Priced

1472

?mm Chromium plated (brass?) barrel bolt with keep fixed to metal

No

Not Priced

?mm Chromium plated (brass?) barrel bolt with keep let into concrete

No

Not Priced

1474

?mm Chromium plated (brass?) necked barrel bolt

No

Not Priced

1475

?mm "Ref ?" flush bolt

No

Not Priced

1476

?mm "Ref ?" flush bolt with keep fixed to metal

No

Not Priced

1477

?mm "Ref ?" flush bolt with keep let into concrete

No

Not Priced

1478

"Ref ?" WC indicator bolt

No

Not Priced

1479

"Ref ?" WC indicator bolt with keep fixed to metal

No

Not Priced

1480

"Ref ?" panic bolt for single (double?) door ?mm high

No

Not Priced

1481

"Ref ?" panic bolt for single (double?) door ?mm high with one keep let into concrete

No

Not Priced

1470

1473

1482

CATCHES, CABIN HOOKS, ETC

1483

Manufactured by "?"

Carried forward Bill No 14 Ironmongery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-196-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1484

In accordance with "?" catalogue

1485

?mm "Ref ?" ball catch

No

Not Priced

1486

?mm "Ref ?" heavy duty ball catch

No

Not Priced

1487

"Ref ?" single roller catch

No

Not Priced

1488

"Ref ?" double roller catch

No

Not Priced

1489

"Ref ?" heavy duty double roller catch

No

Not Priced

1490

"Ref ?" fanlight catch

No

Not Priced

1491

"Ref ?" fanlight stay

No

Not Priced

1492

"Ref ?" fanlight friction sliding arm

No

Not Priced

1493

?mm "Ref ?" fanlight opener with cord and cleat

No

Not Priced

1494

?mm "Ref ?" cabin hook and eye

No

Not Priced

1495

?mm "Ref ?" cabin hook and eye including 70 x 70 x 20mm chamfered hardwood block twice oiled and plugged

No

Not Priced

1496

LOCKS

1497

"EN-SUITE" LOCKS

1498

The following locks are to be suitable for master key operation

1499

The following locks are to be suitable for master and grand master key operation

1500

Manufactured by "?"

1501

In accordance with "?" catalogue

1502

?mm "Ref ?" padlock

No

Not Priced

1503

"Ref ?" latchset

No

Not Priced

1504

"Ref ?" rim night latch

No

Not Priced

1505

"Ref ?" bathroom lockset

No

Not Priced

1506

"Ref ?" bathroom lockset with striking plate fixed to metal

No

Not Priced

Carried forward Bill No 14 Ironmongery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-197-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1507

"Ref ?" three-lever deadlock

No

Not Priced

1508

"Ref ?" three-lever rebated deadlock

No

Not Priced

1509

"Ref ?" four-lever deadlock

No

Not Priced

1510

"Ref ?" four-lever rebated deadlock

No

Not Priced

1511

"Ref ?" two-lever lockset

No

Not Priced

1512

"Ref ?" two-lever lockset with striking plate fixed to metal

No

Not Priced

1513

"Ref ?" two-lever rebated lockset

No

Not Priced

1514

"Ref ?" three-lever lockset

No

Not Priced

1515

"Ref ?" three-lever lockset with striking plate fixed to metal

No

Not Priced

1516

"Ref ?" three-lever rebated lockset

No

Not Priced

1517

"Ref ?" four-lever lockset

No

Not Priced

1518

"Ref ?" four-lever lockset with striking plate fixed to metal

No

Not Priced

1519

"Ref ?" four-lever rebated lockset

No

Not Priced

1520

"Ref ?" three-lever sliding door lock

No

Not Priced

1521

"Ref ?" four-lever sliding door lock

No

Not Priced

1522

"Ref ?" single cylinder deadlock

No

Not Priced

1523

"Ref ?" single cylinder rebated deadlock

No

Not Priced

1524

"Ref ?" double cylinder deadlock

No

Not Priced

1525

"Ref ?" double cylinder rebated deadlock

No

Not Priced

1526

"Ref ?" single cylinder lockset

No

Not Priced

1527

"Ref ?" single cylinder lockset with striking plate fixed to metal

No

Not Priced

1528

"Ref ?" single cylinder rebated lockset

No

Not Priced

1529

"Ref ?" double cylinder lockset

No

Not Priced

1530

"Ref ?" double cylinder lockset with striking plate fixed to metal

No

Not Priced

Carried forward Bill No 14 Ironmongery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-198-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1531

"Ref ?" double cylinder rebated lockset

No

Not Priced

1532

"Ref ?" knob cylinder lockset

No

Not Priced

1533

"Ref ?" knob cylinder lockset with striking plate fixed to metal

No

Not Priced

1534

"Ref ?" single cylinder sliding door lock

No

Not Priced

1535

"Ref ?" double cylinder sliding door lock

No

Not Priced

1536

Master key

No

Not Priced

1537

Grand master key

No

Not Priced

1538

User note

1539

Due to the frequent provisional nature of information with regard to ironmongery at bill production stage, it may be advisable to give the main components of locksets separately in order to facilitate adjustments at final account stage A typical cylinder lockset may then be given as follows:

1540

"Ref ?" cylinder lock case and striking plate

No

Not Priced

1541

"Ref ?" rebate conversion set

No

Not Priced

1542

"Ref ?" single cylinder

No

Not Priced

1543

"Ref ?" single cylinder suitable for master key

No

Not Priced

1544

"Ref ?" cylinder escutcheon

No

Not Priced

1545

"Ref ?" lever handles

Pairs

Not Priced

1546

"Ref ?" lever handles with roses

Pairs

Not Priced

1547

"Ref ?" lever handles with back plates

Pairs

Not Priced

1548

HANDLES

1549

Manufactured by "?"

1550

In accordance with "?" catalogue

1551

?mm "Ref ?" anodised aluminium (chromium plated? brass ?) flush handle

No

Not Priced

Carried forward Bill No 14 Ironmongery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-199-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1552

1553

1554

1555

1556

1557

R

Not Priced

?mm "Ref ?" anodised aluminium (chromium plated? brass ?) knob

No

Not Priced

?mm "Ref ?" anodised aluminium (chromium plated? brass ?) pull handle

No

Not Priced

?mm "Ref ?" anodised aluminium (chromium plated? brass ?) pull handle with roses

No

Not Priced

?mm "Ref ?" anodised aluminium (chromium plated? brass ?) pull handle with back plates

No

Not Priced

?mm "Ref ?" anodised aluminium (chromium plated? brass ?) pull handles fixed back-to-back

Pairs

Not Priced

?mm "Ref ?" anodised aluminium (chromium plated? brass ?) pull handles with roses, fixed back-to-back

Pairs

Not Priced

1558

PUSH PLATES AND KICK PLATES

1559

?mm Thick anodised aluminium plates countersunk screwed along edges at not exceeding 200mm centres

1560

?mm Thick satin finished stainless steel plates countersunk screwed along edges at not exceeding 200mm centres

1561

?mm Thick brass plates countersunk screwed along edges at not exceeding 200mm centres

1562

? x ?mm Push plate

No

Not Priced

1563

? x ?mm Kick plate

No

Not Priced

1564

Manufactured by "?"

1565

In accordance with "?" catalogue

1566

"Ref ?" anodised aluminium (satin finished stainless steel? polished brass?) push plate

No

Not Priced

"Ref ?" anodised aluminium (satin finished stainless steel? polished brass?) kick plate

No

Not Priced

1567

1568

DOOR CLOSERS

1569

Manufactured by "?"

Carried forward Bill No 14 Ironmongery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-200-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1570

In accordance with "?" catalogue

1571

"Ref ?" door selector

No

Not Priced

1572

"Ref ?" door closer

No

Not Priced

1573

"Ref ?" door closer with bracket fixed to metal

No

Not Priced

1574

"Ref ?" door closer with guide rail

No

Not Priced

1575

"Ref ?" door closer with parallel arm

No

Not Priced

1576

"Ref ?" door closer with parallel arm, with bracket fixed to metal

No

Not Priced

1577

"Ref ?" concealed door closer

No

Not Priced

1578

"Ref ?" concealed door closer with bracket fixed to metal

No

Not Priced

1579

SLIDING GEAR

1580

Manufactured by "?"

1581

In accordance with "?" catalogue

1582

"Ref ?" sliding gear set for single door with track ?m long, including brackets for side (soffit?) fixing, hangers, rollers, guides, stops, etc

No

Not Priced

"Ref ?" sliding gear set for bi-parting double door with track ?m long, including brackets for side (soffit?) fixing, hangers, rollers, guides, stops, etc

No

Not Priced

"Ref ?" sliding gear set for set of ? folding doors with track ?m long, including brackets for side (soffit?) fixing, hangers, rollers, guides, stops, etc (hinges elsewhere)

No

Not Priced

1583

1584

1585

LETTERS, NAMEPLATES, ETC

1586

Manufactured by "?"

1587

In accordance with "?" catalogue

1588

?mm High plastic letter or numeral

No

Not Priced

1589

?mm High anodised aluminium (chromium plated? brass?) letter or numeral

No

Not Priced

Carried forward Bill No 14 Ironmongery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-201-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1590

1591

1592

1593

R

Not Priced

? x ? x ?mm Thick perspex plate with ? ?mm high engraved and painted letters or numerals

No

Not Priced

? x ?mm Ref ? anodised aluminium plate with male or female symbol

No

Not Priced

? x ?mm Ref ? anodised aluminium plate with paraplegic symbol

No

Not Priced

? x ?mm Ref ? anodised aluminium plate with fire exit, fire extinguisher, fire hose reel or fire hydrant symbol

No

Not Priced

1594

PHOTOLUMINESCENT SIGNS

1595

SUPPLEMENTARY PREAMBLES

1596

Signs are to comply with SANS 1186-1 to 5 and to be to the approval of the local authority. Signs are to have anodised aluminium frames Prices are to include for fixing by approved methods. The use of double sided tape will not be permitted. Surface mounted signs are to be concealed fixed and ceiling mounted signs are to be hung with 2mm diameter stainless steel cables Single sided ceiling mounted signs are to have 2mm satin chrome anodised aluminium back panels Samples, specifications, literature, etc of materials and fabricated articles the tenderer proposes to use shall be submitted with the tender A ten year guarantee on materials and workmanship shall be submitted by the successful tenderer References at the end of the item descriptions are to the relative items on drawings annexed to (issued separately with?) these bills of quantities

1597

Wall mounted photoluminescent statutory signs in 150 x 150mm modules

1598

Ceiling mounted single sided photoluminescent statutory signs in 150 x 150mm modules

Carried forward Bill No 14 Ironmongery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-202-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1599

Ceiling mounted double sided photoluminescent statutory signs in 150 x 150mm modules

1600

150 x 150mm Sign with one number (Type ?)

No

Not Priced

1601

150 x 150mm Sign with one pictogram (Type ?)

No

Not Priced

1602

300 x 150mm Sign with two pictograms (Type ?)

No

Not Priced

1603

300 x 150mm Sign with EXIT sign (Type ?)

No

Not Priced

1604

450 x 150mm Sign with three pictograms (Type ?)

No

Not Priced

1605

600 x 150mm Sign with four pictograms (Type ?)

No

Not Priced

1606

Wall mounted photoluminescent statutory signs in 190 x 190mm modules

1607

Ceiling mounted single sided photoluminescent statutory signs in 190 x 190mm modules

1608

Ceiling mounted double sided photoluminescent statutory signs in 190 x 190mm modules

1609

190 x 190mm Sign with one number (Type ?)

No

Not Priced

1610

190 x 190mm Sign with one pictogram (Type ?)

No

Not Priced

1611

380 x 190mm Sign with two pictograms (Type ?)

No

Not Priced

1612

380 x 190mm Sign with EXIT sign (Type ?)

No

Not Priced

1613

570 x 190mm Sign with three pictograms (Type ?)

No

Not Priced

1614

760 x 190mm Sign with four pictograms (Type ?)

No

Not Priced

1615

PELMETS AND CURTAIN TRACKS

1616

Manufactured by "?"

1617

In accordance with "?" catalogue

1618

Pressed steel pelmets ?mm high with ?mm projection, including single (double?) curtain track with 12 rollers per metre, stops, brackets, returned ends, etc (plugged?)

m

Not Priced

"Ref ?" single (double?) curtain tracks for soffit fixing including 12 rollers per metre, stops, brackets, etc (plugged?)

m

Not Priced

1619

Carried forward Bill No 14 Ironmongery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-203-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1620

1621

R

Not Priced

"Ref ?" single (double?) curtain tracks for face fixing with ?mm projection including 12 rollers per metre, stops, brackets, etc (plugged?)

m

Not Priced

"Ref ?" hospital cubicle curtain tracks ?mm below soffit including 12 gliders per metre, hangers, brackets, stopped ends, etc (plugged?)

m

Not Priced

1622

Extra over for end bracket plugged

No

Not Priced

1623

Extra over for slow bend

No

Not Priced

1624

Extra over for T-intersection with slow bend

No

Not Priced

1625

SUNDRIES

1626

Manufactured by "?"

1627

In accordance with "?" catalogue

1628

?mm Diameter steel dowel ?mm long in and including mortice in timber and brickwork or concrete

No

Not Priced

1629

38mm Diameter rubber door stop (, plugged?)

No

Not Priced

1630

"Ref ?" door stop, plugged

No

Not Priced

1631

"Ref ?" chromium plated (brass?) coat hook

No

Not Priced

1632

"Ref ?" chromium plated (brass?) hat and coat hook

No

Not Priced

1633

"Ref ?" chromium plated (brass?) hat and coat hook with rubber buffer

No

Not Priced

32mm Diameter polished hardwood longarm ?m long with brass pole hook on one end, two broom clips each with 20 x 70 x 70mm wrought and chamfered hardwood block twice oiled and plugged and 20 x 70 x 70mm wrought and chamfered hardwood block with sinking, twice oiled and plugged

No

Not Priced

"Ref ?" anodised aluminium (stainless steel? brass?) cover strips fixed over expansion joints in floors

m

Not Priced

"Ref ?" anodised aluminium (stainless steel? brass?) cover strips fixed over expansion joints in walls and ceilings

m

Not Priced

"Ref ?" smoke seal strips let into edges of doors

m

Not Priced

1634

1635

1636

1637

Carried forward Bill No 14 Ironmongery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-204-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1638

1639

R

Not Priced

"Ref ?" air (sound?) seal strips fixed to top and vertical edges of ? x ?mm high single door

No

Not Priced

"Ref ?" air (sound?) seal strips fixed to bottom of ?mm wide single door

No

Not Priced

1640

Coir door mats

1641

Rubber door mats

1642

Door mats manufactured by "?"

1643

? x ? x ?mm Door mat laid loose in mat surround

No

Not Priced

1644

? x ? x ?mm "Ref ?" door mat laid loose in mat surround

No

Not Priced

1645

BATHROOM FITTINGS

1646

Manufactured by "?"

1647

In accordance with "?" catalogue

1648

?mm Diameter chromium plated (stainless steel? polished brass?) curtain or hanging rail ?mm long including flanged end brackets (, plugged?)

No

Not Priced

?mm Diameter chromium plated (stainless steel? polished brass?) towel rail ?mm long including end brackets (, plugged?)

No

Not Priced

"Ref ?" chromium plated (stainless steel? polished brass?) towel ring (, plugged)

No

Not Priced

"Ref ?" chromium plated (stainless steel? polished brass?) toilet roll holder, plugged

No

Not Priced

"Ref ?" chromium plated (stainless steel? polished brass?) l ockable toilet roll holder, plugged

No

Not Priced

"Ref ?" chromium plated (stainless steel? polished brass?) soap dish, plugged

No

Not Priced

1654

"Ref ?" soap dispenser, plugged

No

Not Priced

1655

"Ref ?" paper towel dispenser, plugged

No

Not Priced

1656

"Ref ?" towel roll holder, plugged

No

Not Priced

1649

1650

1651

1652

1653

Carried forward Bill No 14 Ironmongery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-205-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1657

R

Not Priced

32mm "Ref ?" chromium plated (stainless steel?) back grab rail ?mm long, plugged

No

Not Priced

32mm "Ref ?" chromium plated (stainless steel?) side grab rail ?mm girth, plugged

No

Not Priced

1659

? x ?mm High "Ref ?" bathroom cabinet, plugged

No

Not Priced

1660

SHELVES ETC

1661

"?" proprietary type steel shelving with standard powder coated finish

1662

"Ref ?" single slot wall band ?mm long, plugged

No

Not Priced

1663

"Ref ?" double slot wall band ?mm long, plugged

No

Not Priced

1664

"Ref ?" shelf bracket for ?mm shelf

No

Not Priced

1665

? x ?mm "Ref ?" shelf

No

Not Priced

1666

"?" free standing proprietary type steel shelving units with standard powder coated finish, including heavy duty uprights, open base foot pieces, shelf brackets, shelves, spacers, top rails, top finishing plates and adjustable book clips

1667

Single (Double?) shelving unit ? x ? x ?m high in ? bays with ? uprights, each bay 914mm wide with ? x ?mm shelves

No

Not Priced

1658

1668

STEEL LOCKERS

1669

"?" steel lockers with standard baked enamel finish

1670

"Ref ?" locker ? x ? x ?mm high

No

Not Priced

1671

Bank of ? "Ref ?" lockers each ? x ? x ?mm high, bolted together

No

Not Priced

1672

PROPRIETARY TYPE KITCHEN CUPBOARDS

Carried forward Bill No 14 Ironmongery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-206-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1673

SUPPLEMENTARY PREAMBLES

1674

Kitchen cupboards are to be manufactured of 16 mm particle board with 0,8mm melamine finish on both sides and edges. Tops are to be of 32mm water resistant particle board with 1,2mm "Formica" type ? plastic laminate finish to top with balancing veneer to underside. Edges of tops are to be finished with matching laminate (Edges of tops are to be half-round post-formed with laminate wrapped around?)

1675

Doors to be of 16mm particle board with 0,8mm melamine finish on both sides and edges (Doors to be of 16mm "Supawood" with half-round edges and with 0,8mm melamine finish on both sides and wrapped around edges?)

1676

Drawers are to be fitted with telescopic runners

1677

Doors are to be hung on "?" self closing adjustable hinges

1678

Doors and drawers are to be fitted with "?" handles (knobs ?)

1679

Where described as "lockable", doors and drawers are to be fitted with "?" cylinder cupboard locks with necked barrel bolts to double doors

1680

"?" kitchen cupboards, plugged

1681

"Ref ?" wall unit ? x ? x ?mm high

No

Not Priced

1682

"Ref ?" floor unit ? x ? x ?mm high (granite top elsewhere)

No

Not Priced

1683

User note

1684

Granite tops may also be included in the descriptions of floor units

1685

"Ref ?" floor unit ? x ? x ?mm high

No

Not Priced

1686

"Ref ?" floor unit ? x ? x ?mm high with lockable doors and drawers

No

Not Priced

1687

"Ref ?" sink unit ? x ? x ?mm high

No

Not Priced

1688

PINNING BOARDS, WRITING BOARDS, PROJECTION SCREENS, ETC

1689

Manufactured by "?"

Carried forward Bill No 14 Ironmongery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-207-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1690

In accordance with "?" catalogue

1691

"Ref ?" pinning board ? x ?mm high, plugged

No

Not Priced

1692

"Ref ?" green (white?) writing board ? x ?mm high with chalk rail, plugged

No

Not Priced

"Ref ?" green (white?) folding type writing board, with wall mounted centre board ? x ?mm high with chalk rail and two swing leaves each ? x ?mm high, plugged

No

Not Priced

"Ref ?" column mounted vertical sliding type green (white?) writing board with two boards each ? x ?mm high with chalk rail and with pair of columns ?mm high, plugged

No

Not Priced

"Ref ?" tilting spring roller wall mounted projection screen ? x ?mm high including overhead brackets, plugged

No

Not Priced

1693

1694

1695

Carried to summary Bill No 14 Ironmongery ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-208-

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

1696

BILL NO ?

1697

STRUCTURAL STEELWORK

1698

User note

1699

Consideration is to be given in specific applications (eg where "heavy" steel structures such as in industrial plants, towers for mine shafts, etc are dominant) to implement the principles laid down by the "Measurement for Structural Steelwork" as prepared and recommended by the South African Institute of Steel Construction

Quantity

Rate

Amount

This bill however is based on the Standard System of Measuring Building Work Sixth Edition (Revised) 1700

SUPPLEMENTARY PREAMBLES

1701

Descriptions

1702

Descriptions of bolts shall be deemed to include nuts and washers

1703

Descriptions of L-shaped and U-shaped anchor bolts shall be deemed to include bending, threading, nuts and washers and embedding in concrete

1704

Descriptions of expansion anchors and bolts and chemical anchors and bolts shall be deemed to include nuts, washers and mortices in brickwork or concrete

1705

STEEL COLUMNS AND BEAMS

1706

GALVANISED STEEL COLUMNS AND BEAMS

1707

User note

1708

In the event of there being only a limited number of different heights or lengths of columns or beams, the specific heights or lengths may be given separately or may be suitably grouped together

1709

Welded columns in single lengths with flat base, cap, bearer and connection plates, bolted to concrete

1710

? x ?mm x ?kg/m I-section (H-section? U-section?) columns

t

Not Priced

1711

? x ?mm x ?kg/m I-section (H-section? U-section?) columns in heights exceeding 13m and not exceeding 18m

t

Not Priced

Carried forward Bill No 15 Structural Steelwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-209-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1712

? x ?mm x ?kg/m I-section (H-section? U-section?) columns in heights exceeding ?m and not exceeding ?m

R

Not Priced

t

Not Priced

1713

Welded beams in single lengths with flat bearer and connection plates, bolted to steel

1714

? x ?mm x ?kg/m I-section (H-section? U-section?) beams

t

Not Priced

1715

? x ?mm x ?kg/m I-section (H-section? U-section?) beams in lengths exceeding 13m and not exceeding 18m

t

Not Priced

? x ?mm x ?kg/m I-section (H-section? U-section?) beams in lengths exceeding ?m and not exceeding ?m

t

Not Priced

1716

1717

Welded compound columns consisting of one (two?) ? x ?mm x ?kg/m I-section(s) (H-section? U-section?) and one (two?) ? x ?mm x ?kg/m I-section(s) (H-section? U-section?) with flat base, cap, bearer and connection plates, bolted to concrete

1718

? x ?mm Compound columns

t

Not Priced

1719

? x ?mm Compound columns in heights exceeding 13m and not exceeding 18m

t

Not Priced

? x ?mm Compound columns in heights exceeding ?m and not exceeding ?m

t

Not Priced

1720

1721

Welded compound beams consisting of one (two?) ? x ?mm x ?kg/m I-section(s) (H-section? U-section?) and one (two?) ? x ?mm x ?kg/m I-section(s) (H-section? U-section?) with flat bearer and connection plates, bolted to steel

1722

? x ?mm Compound beams

t

Not Priced

1723

? x ?mm Compound beams in lengths exceeding 13m and not exceeding 18m

t

Not Priced

? x ?mm Compound beams in lengths exceeding ?m and not exceeding ?m

t

Not Priced

t

Not Priced

1724

1725

Welded plate columns, with flat base, cap, bearer and connection plates, bolted to concrete

1726

? x ?mm I-section columns of ? x ?mm flanges and ? x ?mm web

Carried forward Bill No 15 Structural Steelwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-210-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1727

R

Not Priced

? x ?mm I-section columns of ? x ?mm flanges and ? x ?mm web, in heights exceeding 13m and not exceeding 18m t

Not Priced

? x ?mm I-section columns of ? x ?mm flanges and ? x ?mm web, in heights exceeding ?m and not exceeding ?m

t

Not Priced

1729

? x ?mm Box section columns of ?mm thick sides

t

Not Priced

1730

? x ?mm Box section columns of ?mm thick sides, in heights exceeding 13m and not exceeding 18m

t

Not Priced

? x ?mm Box section columns of ?mm thick sides, in heights exceeding ?m and not exceeding ?m

t

Not Priced

1728

1731

1732

Welded plate beams, with flat bearer and connection plates, bolted to steel

1733

? x ?mm I-section beams of ? x ?mm flanges and ? x ?mm web

t

Not Priced

? x ?mm I-section beams of ? x ?mm flanges and ? x ?mm web, in lengths exceeding 13m and not exceeding 18m

t

Not Priced

? x ?mm I-section beams of ? x ?mm flanges and ? x ?mm web, in lengths exceeding ?m and not exceeding ?m

t

Not Priced

1736

? x ?mm Box section beams of ?mm thick sides

t

Not Priced

1737

? x ?mm Box section beams of ?mm thick sides, in lengths exceeding 13m and not exceeding 18m

t

Not Priced

? x ?mm Box section beams of ?mm thick sides, in lengths exceeding ?m and not exceeding ?m

t

Not Priced

1734

1735

1738

1739

Welded lattice columns of ? x ? x ?mm, ? x ? x ?mm and ? x ? x ?mm angle framework and bracing, with flat base, cap, bearer, gusset and connection plates, bolted to concrete

1740

? x ?mm Lattice columns

t

Not Priced

1741

? x ?mm Lattice columns in heights exceeding 13m and not exceeding 18m

t

Not Priced

? x ?mm Lattice columns in heights exceeding ?m and not exceeding ?m

t

Not Priced

1742

Carried forward Bill No 15 Structural Steelwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-211-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1743

Welded lattice beams of ? x ? x ?mm, ? x ? x ?mm and ? x ? x ?mm angle framework and bracing, with flat bearer, gusset and connection plates, bolted to steel

1744

? x ?mm Lattice beams

t

Not Priced

1745

? x ?mm Lattice beams in lengths exceeding 13m and not exceeding 18m

t

Not Priced

? x ?mm Lattice beams in lengths exceeding ?m and not exceeding ?m

t

Not Priced

1746

1747

Welded castellated beams in single lengths with flat bearer and connection plates, bolted to steel

1748

? x ?mm x ?kg/m I-section (H-section?) castellated beams

t

Not Priced

1749

? x ?mm x ?kg/m I-section (H-section?) castellated beams in lengths exceeding 13m and not exceeding 18m

t

Not Priced

? x ?mm x ?kg/m I-section (H-section?) castellated beams in lengths exceeding ?m and not exceeding ?m

t

Not Priced

1750

1751

STEEL PORTAL FRAMES

1752

GALVANISED STEEL PORTAL FRAMES

1753

Welded portal frames with flat bearer, gusset and connection plates and angle cleats, bolted to concrete

1754

Double pitched portal frames ?m wide x ?m high extreme of ? x ?mm x ?kg/m I-section (H-section? U-section?) rafters and columns (In No ?)

t

Not Priced

Double pitched portal frames ?m wide x ?m high extreme in two sections bolted together at apex, of ? x ?mm x ?kg/m I-section (H-section? U-section?) rafters and columns (In No ?)

t

Not Priced

1755

1756

STEEL TRUSSES

1757

GALVANISED STEEL TRUSSES

1758

Welded roof trusses of angle rafters, tie beams, rails, struts, braces, cleats, etc and flat bearer, gusset and connection plates, bolted to steel

Carried forward Bill No 15 Structural Steelwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-212-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1759

Welded roof trusses of rectangular (round?) hollow section rafters, tie beams, rails, struts, braces, cleats, etc and flat bearer, gusset and connection plates, bolted to steel

1760

Monopitched trusses ? x ?m high extreme (In No ? )

t

Not Priced

1761

Double pitched trusses ? x ?m high extreme (In No ?)

t

Not Priced

1762

Lattice trusses ?m long x ?m high extreme (In No ?)

t

Not Priced

1763

Lattice trusses in two sections bolted together, ?m long x ?m high extreme (In No ?)

t

Not Priced

1764

STEEL PURLINS, GIRTS, BRACING, ETC

1765

GALVANISED STEEL PURLINS, GIRTS, BRACING, ETC

1766

Purlins and girts, bolted to steel

1767

Angle purlins

t

Not Priced

1768

Angle girts

t

Not Priced

1769

? x ? x ? x ?mm Thick cold-formed lipped channel purlins

t

Not Priced

1770

? x ? x ? x ?mm Thick cold-formed lipped channel girts

t

Not Priced

1771

Purlins of two ? x ? x ? x ?mm thick cold-formed lipped channels welded back-to-back

t

Not Priced

1772

Welded bracing, anti-sag rails, etc with flat connection plates, bolted to steel

1773

Angle bracing

t

Not Priced

1774

Angle anti-sag rails

t

Not Priced

1775

Round anti-sag rods with threaded ends

t

Not Priced

1776

Round hollow section bracing

t

Not Priced

1777

Welded box gutter bearers with flat cleats, bolted to steel

1778

Angle longitudinal bearers

t

Not Priced

1779

Angle cross bearers

t

Not Priced

1780

STEEL GUTTERS AND RAINWATER PIPES

Carried forward Bill No 15 Structural Steelwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-213-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1781

GALVANISED STEEL GUTTERS AND RAINWATER PIPES

1782

?mm Welded plate gutters

1783

Box gutters ?mm girth, ? times bent along length including necessary collared and sealed expansion joints (bearers elsewhere)

R

Not Priced

t

Not Priced

t

Not Priced

1784

?mm Welded plate rainwater pipes, including holderbats, brackets, etc

1785

?mm Internal diameter pipes

1786

STEEL HAILGUARDS

1787

"?" type ? galvanised expanded metal

1788

Hailguards ?mm wide and in suitable lengths, laid loose over box gutters

m

Not Priced

Hailguards ?mm girth and in suitable lengths, twice bent along length, laid loose in box gutters

m

Not Priced

Hailguards ?mm wide and in suitable lengths with ? x ? x ?mm angle framing welded at angles, laid loose over box gutters

m

Not Priced

1789

1790

1791

STEEL FLOORS, STAIRS, ETC

1792

GALVANISED STEEL FLOORS, STAIRS, ETC

1793

Welded and bolted suspended floor and stairs to workshop

1794

? x ?mm x ?kg/m Channel columns

t

Not Priced

1795

? x ?mm x ?kg/m Channel bearers

t

Not Priced

1796

Framing to stair ? x ?m overall on plan and rising approximately ?m high, of channel columns and bearers and flat stringers

t

Not Priced

1797

"Vastrap" plate floor panels

t

Not Priced

1798

"Vastrap" plate treads ?mm long x ?mm wide with ?mm turn-down nosing

t

Not Priced

m

Not Priced

1799

? x ?mm Kick flats welded on

Carried forward Bill No 15 Structural Steelwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-214-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1800

"?" type ? floor grating with ? x ?mm bearer bars, fixed to steel with standard fixing clips

1801

Floor grating of unbanded panels in ?mm widths and suitable lengths



Not Priced

1802

Floor grating of ? x ?mm banded panels



Not Priced

1803

Circular cutting

m

Not Priced

1804

? x ?mm Kick flats welded on

m

Not Priced

1805

Banded tread ?mm long and ?mm wide with end plates and heavy embossed nosing

No

Not Priced



Not Priced

m

Not Priced

1806

"?" type ? expanded metal walkway mesh with standard flow coat bitumastic paint finish, fixed to steel with standard fixing clips

1807

Floor mesh in ?mm widths and suitable lengths

1808

Circular cutting

1809

BALUSTRADES ETC

1810

"?" welded and bolted patent balustrades to stairs

1811

Horizontal balustrades ?mm high of ?mm diameter continuous top and bottom rails and ?mm diameter type ? stanchions at average ?mm centres, bolted to steel (concrete?)

m

Not Priced

Raking balustrades ?mm high of ?mm diameter continuous top and bottom rails and ?mm diameter type ? stanchions at average ?mm centres, bolted to steel (concrete?)

m

Not Priced

1812

1813

Extra over for short radius bend

No

Not Priced

1814

Extra over for long radius bend

No

Not Priced

1815

Extra over for ? degree bend

No

Not Priced

1816

Extra over for ? degree ramp bend

No

Not Priced

1817

Extra over for ? degree ramp return bend

No

Not Priced

1818

Extra over for end closure to horisontal balustrade

No

Not Priced

1819

Extra over for end closure to raking balustrade

No

Not Priced

Carried forward Bill No 15 Structural Steelwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-215-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1820

BOLTS, FASTENERS, ETC

1821

High tensile bolts (class 8.8)

t

Not Priced

1822

High strength friction grip bolts (class 10.9S)

t

Not Priced

1823

?mm Diameter Huck bolt

No

Not Priced

1824

?mm Diameter expansion bolt

No

Not Priced

1825

?mm Diameter chemical anchor

No

Not Priced

1826

?mm Diameter L-shaped threaded anchor bolt ?mm girth embedded in top (side?) of concrete

No

Not Priced

?mm Diameter U-shaped threaded anchor bolt ?mm girth embedded in top (side?) of concrete

No

Not Priced

Anchor assembly consisting of two (four?) ?mm diameter L-shaped threaded anchor bolts each ?mm girth, caged together with ? x ? x ?mm angle, total length of angle ?mm

No

Not Priced

No

Not Priced

1827

1828

1829

TESTS

1830

Weld testing

1831

X-Ray test of ?mm long butt weld joint to ?mm thick web plate

1832

MPI testing of ?% of all fillet welds

Item

Not Priced

1833

Provide the sum of R? for quality control inspection by an authorised independent inspection authority

Item

Not Priced

1834

Profit

Item

Not Priced

1835

Attendance

Item

Not Priced

1836

User note

1837

Finishing-off painting is to be included in this trade only when the structural steel contractor is required to execute the work

1838

PAINTING

Carried forward Bill No 15 Structural Steelwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-216-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1839

Touch-up ? primer, one coat ? undercoat to ? micron dry film thickness and one ? finishing coat to ? micron dry film thickness

1840

On structural steel (galvanised steel?) columns, beams, etc



Not Priced

1841

On structural steel (galvanised steel?) lattice columns, beams, trusses, etc



Not Priced

1842

On steel (galvanised steel?) purlins, girts, etc



Not Priced

1843

On "Vastrap" plate floors



Not Priced

1844

On ? floor grating



Not Priced

1845

On top and bottom rails, posts, etc of type ? patent balustrades

m

Not Priced

1846

Paint testing

1847

Provide the sum of R? for quality control inspection by an authorised independent inspection authority

Item

Not Priced

1848

Profit

Item

Not Priced

1849

Attendance

Item

Not Priced

Carried to summary Bill No 15 Structural Steelwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-217-

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

1850

BILL NO ?

1851

METALWORK

1852

SUPPLEMENTARY PREAMBLES

1853

Descriptions of bolts, anchors, etc

1854

Descriptions of bolts shall be deemed to include nuts and washers

1855

Descriptions of expansion anchors and bolts and chemical anchors and bolts shall be deemed to include nuts, washers and mortices in brickwork or concrete

1856

Items described as "holed for bolt(s)" shall be deemed to exclude the bolts unless otherwise described

1857

Items described as "plugged" shall be deemed to include screwing to fibre, plastic or metal plugs at not exceeding 600mm centres

1858

Aluminium doors, windows, etc

1859

Doors and windows shall comply with AAAMSA design criteria

Quantity

Rate

Amount

Glazing shall comply with SAGGA regulations. Glass shall be type ? laminated performance glass as shown on the window schedules/drawings appended to these bills of quantities (as described in the headings to window descriptions?). Glass thickness shall comply with SAGGA regulations irrespective of thicknesses shown on the schedules/drawings Doors and windows shall be supplied with protective tape and plastic and shall be removed only once surrounding trades have been completed For purpose made windows and doors, refer to drawings annexed to (issued separately with?) these bills of quantities

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-218-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1860

1861

R

Not Priced

The following certificates shall be provided prior to commencement of site work: 1

A copy of the relevant AAAMSA Performance Test Certificate from the manufacturer/contractor supplying the architectural aluminium product

2

A Certificate of Conformance confirming that anodising or powder coating has been processed in accordance with SANS 999 and SANS 1796 respectively

3

A powder guarantee of not less than 15 years issued by the powder manufacturer. The specific conditions contained in this guarantee shall form part of the powder coating process

4

A Certificate of Conformance confirming that glazing has been installed in accordance with SANS 0137, ensuring that safety glazing materials have been installed in the mandatory areas and that each individual pane of safety glazing materials has been permanently marked

5

A warranty from the manufacturer of the laminated safety glass and/or hermetically sealed glazing units guaranteeing the products against delamination and colour degredation for a period of not less than five years

1862

STEEL HANDRAILS

1863

GALVANISED STEEL HANDRAILS Welded handrails to (stair?) walls

1865

? x ?mm Flat section (continuous?) rails

kg

Not Priced

1866

? x ? x ?mm Hollow section (continuous?) rails

m

Not Priced

1867

?mm External diameter x ?mm thick (continuous?) pipe rails

m

Not Priced

1868

User note

1869

The applicable labour items from the following list are to be inserted directly after each of the foregoing items

1870

Extra over for fanged end

No

Not Priced

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-219-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1871

Extra over for rounded end

No

Not Priced

1872

Extra over for flat closed end

No

Not Priced

1873

Extra over for rounded closed end

No

Not Priced

1874

Extra over for L-intersection

No

Not Priced

1875

Extra over for mitred L-intersection

No

Not Priced

1876

Extra over for T-intersection

No

Not Priced

1877

Extra over for ramp or knee

No

Not Priced

1878

Extra over for bend to ?mm internal radius

No

Not Priced

1879

Extra over for bend across edge

No

Not Priced

1880

Extra over for bend across edge to ?mm internal radius

No

Not Priced

1881

Extra over for wreathed ramp

No

Not Priced

1882

Extra over for double wreathed ramp

No

Not Priced

1883

Bracket of ?mm diameter bar ?mm girth, once bent to ?mm internal radius and with one end welded to rail and other end with ?mm diameter x ?mm thick plate ? holed for bolt(s) and welded on

No

Not Priced

1884

?mm Expansion bolt

No

Not Priced

1885

?mm Expansion anchor with loose bolt

No

Not Priced

1886

?mm Chemical anchor with loose bolt

No

Not Priced

1887

STEEL BALUSTRADES

1888

GALVANISED STEEL BALUSTRADES Welded balustrades to walkways (and stairs?)

1890

? x ?mm Flat section continuous handrails

kg

Not Priced

1891

? x ?mm Flat section continuous middle and bottom rails

kg

Not Priced

1892

? x ?mm Flat section balusters

kg

Not Priced

1893

? x ?mm Square (rectangular?) section balusters

kg

Not Priced

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-220-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1894

?mm Diameter balusters

kg

Not Priced

1895

? x ? x ?mm Hollow section continuous handrails

m

Not Priced

1896

? x ? x ?mm Hollow section balusters

m

Not Priced

1897

?mm External diameter x ?mm thick continuous pipe handrails

m

Not Priced

1898

?mm External diameter x ?mm thick pipe balusters

m

Not Priced

1899

User note

1900

The applicable labour items from the following list are to be inserted directly after each of the foregoing items

1901

Extra over for fanged end

No

Not Priced

1902

Extra over for rounded end

No

Not Priced

1903

Extra over for flat closed end

No

Not Priced

1904

Extra over for rounded closed end

No

Not Priced

1905

Extra over for L-intersection

No

Not Priced

1906

Extra over for mitred L-intersection

No

Not Priced

1907

Extra over for T-intersection

No

Not Priced

1908

Extra over for irregular T-intersection

No

Not Priced

1909

Extra over for framed X-intersection

No

Not Priced

1910

Extra over for ramp or knee

No

Not Priced

1911

Extra over for bend

No

Not Priced

1912

Extra over for bend to ?mm internal radius

No

Not Priced

1913

Extra over for bend across edge

No

Not Priced

1914

Extra over for bend across edge to ?mm internal radius

No

Not Priced

1915

Extra over for wreathed ramp

No

Not Priced

1916

Extra over for double wreathed ramp

No

Not Priced

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-221-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1917

R

Not Priced

?mm Diameter threaded lug ?mm long with one end welded on and other end fitted with nut and washer

No

Not Priced

1918

? x ? x ?mm Fixing plate ? holed for bolt(s) and welded on

No

Not Priced

1919

L-shaped bracket of ? x ?mm flat section ?mm girth ? holed for bolt(s) and welded on

No

Not Priced

Bracket of ?mm diameter bar ?mm girth, once bent to ?mm internal radius with one end welded to rail and other end with ?mm diameter x ?mm thick plate ? holed for bolt(s) and welded on

No

Not Priced

1921

Hole through ?mm steel for bolt

No

Not Priced

1922

Slotted hole through ?mm steel for bolt

No

Not Priced

1923

Bolts

kg

Not Priced

1924

?mm Expansion bolt

No

Not Priced

1925

?mm Expansion anchor with loose bolt

No

Not Priced

1926

?mm Chemical anchor with loose bolt

No

Not Priced

? x ? x ?mm Welded mesh infill panels ?mm high and in single lengths, spot welded to sub-frames

m

Not Priced

? x ? x ?mm Angle section sub-frames spot welded to frames

kg

Not Priced

1930

Extra over for mitred L-intersection

No

Not Priced

1931

Extra over for T-intersection

No

Not Priced

1932

? x ? x ?mm Hollow section frames

m

Not Priced

1933

Extra over for T-intersection

No

Not Priced

1934

Extra over for mitred L-intersection

No

Not Priced

1935

? x ? x ?mm Hollow section spacer ?mm long with ends welded to posts

No

Not Priced

? x ? x ?mm Hollow section post ?mm long with top welded to frame and bottom with ? x ? x ?mm foot plate ? holed for bolt(s) and welded on

No

Not Priced

1920

Welded balustrades to walkways (and stairs?) 1928

1929

1936

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-222-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1937

R

Not Priced

? x ? x ?mm Hollow section post ?mm long with flat closed top and bottom, with ? x ? x ?mm foot plate ? holed for bolt(s) and welded on

No

Not Priced

1938

?mm Expansion bolt

No

Not Priced

1939

?mm Expansion anchor with loose bolt

No

Not Priced

1940

?mm Chemical anchor with loose bolt

No

Not Priced

1941

Welded balustrades to walkways (and stairs?)

1942

User note

1943

Alternative to detail measurement

1944

Horizontal balustrades to walkways of ? x ?mm flat section continuous top rail, ? x ?mm flat section continuous bottom rail, ? x ?mm ? section intermediate balusters at ?mm centres between top and bottom rails and ? x ?mm ? section posts at approximately ?mm centres each with ? x ? x ?mm flat section base plate bolted to concrete (bolts elsewhere)

kg

Not Priced

Raking balustrades to staircases of ? x ?mm flat section continuous top rail, ? x ?mm flat section continuous bottom rail, ? x ?mm ? section intermediate balusters at ?mm centres between top and bottom rails and ? x ?mm ? section posts at approximately ?mm centres each with ? x ? x ?mm flat section base plate bolted to concrete (bolts elsewhere)

kg

Not Priced

Horizontal balustrades 1000mm high, of ?mm external diameter x ?mm thick continuous pipe handrail, ? x ?mm flat section continuous top and bottom rails, ? x ?mm flat section posts at approximately ?mm centres with ? x ? x ?mm footplates bolted to concrete (bolts elsewhere) and ? x ?mm intermediate vertical balusters at ?mm centres between top and bottom rails (Type ?) (Drawing No ?)

m

Not Priced

Raking balustrades 1000mm high, of ?mm external diameter x ?mm thick continuous pipe handrail, ? x ?mm flat section continuous top and bottom rails, ? x ?mm flat section posts at approximately ?mm centres with ? x ? x ?mm footplates bolted to concrete (bolts elsewhere) and ? x ?mm intermediate vertical balusters at ?mm centres between top and bottom rails (Type ?) (Drawing No ?)

m

Not Priced

1945

1946

1947

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-223-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 1948

1949

R

Not Priced

Horizontal balustrades 1000mm high circular on plan to approximately ?m radius of ?mm external diameter x ?mm thick continuous pipe handrail, ? x ?mm flat section continuous top and bottom rails, ? x ?mm flat section posts at approximately ?mm centres with ? x ? x ?mm footplates bolted to concrete (bolts elsewhere) and ? x ?mm intermediate vertical balusters at ?mm centres between top and bottom rails (Type ?) (Drawing No ?)

m

Not Priced

Raking balustrades 1000mm high circular on plan to approximately ?m radius of ?mm external diameter x ?mm thick continuous pipe handrail, ? x ?mm flat section continuous top and bottom rails, ? x ?mm flat section posts at approximately ?mm centres with ? x ? x ?mm footplates bolted to concrete (bolts elsewhere) and ? x ?mm intermediate vertical balusters at ?mm centres between top and bottom rails (Type ?) (Drawing No ?)

m

Not Priced

1950

Extra over for L-intersection of horizontal balustrades

No

Not Priced

1951

Extra over for junction of end of horizontal with end of raking balustrades

No

Not Priced

1952

?mm Expansion bolt

No

Not Priced

1953

?mm Expansion anchor with loose bolt

No

Not Priced

1954

?mm Chemical anchor with loose bolt

No

Not Priced

m

Not Priced

"?" welded and bolted patent balustrades to walkways (and stairs?) 1956

?mm Diameter continuous pipe top and bottom rails

1957

Extra over for short radius bend

No

Not Priced

1958

Extra over for long radius bend

No

Not Priced

1959

Extra over for ? degree bend

No

Not Priced

1960

Extra over for ? degree ramp bend

No

Not Priced

1961

Extra over for ? degree ramp return bend

No

Not Priced

1962

Extra over for end closure to horizontal balustrade

No

Not Priced

1963

Extra over for end closure to raking balustrade

No

Not Priced

1964

?mm Diameter type ? stanchion ?m long

No

Not Priced

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-224-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1965

?mm Expansion bolt

No

Not Priced

1966

?mm Expansion anchor with loose bolt

No

Not Priced

1967

?mm Chemical anchor with loose bolt

No

Not Priced

"?" welded and bolted patent balustrades to walkways (and stairs?) 1969

User note

1970

Alternative to detail measurement

1971

Horizontal balustrades ?mm high of ?mm diameter continuous pipe top and bottom rails and ?mm diameter type ? stanchions at average ?mm centres bolted to concrete (steel?) (bolts elsewhere)

m

Not Priced

Raking balustrades ?mm high of ?mm diameter continuous pipe top and bottom rails and ?mm diameter type ? stanchions at average ?mm centres bolted to concrete (steel?) (bolts elsewhere)

m

Not Priced

1972

1973

Extra over for short radius bend

No

Not Priced

1974

Extra over for long radius bend

No

Not Priced

1975

Extra over for ? degree bend

No

Not Priced

1976

Extra over for ? degree ramp bend

No

Not Priced

1977

Extra over for ? degree ramp return bend

No

Not Priced

1978

Extra over for end closure to horizontal balustrade

No

Not Priced

1979

Extra over for end closure to raking balustrade

No

Not Priced

1980

?mm Expansion bolt

No

Not Priced

1981

?mm Expansion anchor with loose bolt

No

Not Priced

1982

?mm Chemical anchor with loose bolt

No

Not Priced

1983

GLAZED ALUMINIUM BALUSTRADES

1984

"?" (Dark bronze?) anodised aluminium and glass balustrades to walkways (and stairs?)

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-225-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

1985

"?" powder coated aluminium and glass balustrades to walkways (and stairs?)

1986

Horizontal balustrades ?mm high of "?" continuous top rails, "?" bottom rails ?mm below top rails, "?"mm posts at ?mm centres secret fixed to concrete, the rails and posts fitted with glazing beads and ?mm toughened safety glass ?mm high

m

Not Priced

Raking balustrades ?mm high of "?" continuous top rails, "?" bottom rails ?mm below top rails, "?"mm posts at ?mm centres secret fixed to concrete, the rails and posts fitted with glazing beads and ?mm toughened safety glass ?mm high (perpendicular to top and bottom rails)

m

Not Priced

1987

1988

Extra over for L-intersection of horizontal balustrades

No

Not Priced

1989

Extra over for ramped junction of end of horizontal with end of raking balustrades

No

Not Priced

"?" (Black?) anodised aluminium and structural glass balustrades to walkways (and stairs?) "?" powder coated aluminium and structural glass balustrades to walkways (and stairs?) 1992

?mm Diameter type ? handrails to suit ?mm glass

m

Not Priced

1993

? x ?mm Type ? handrails to suit ?mm glass

m

Not Priced

1994

Extra over for flat closed end

No

Not Priced

1995

Extra over for rounded closed end

No

Not Priced

1996

Extra over for ramp or knee

No

Not Priced

1997

Extra over for mitred L-intersection

No

Not Priced

1998

? x ? x ?mm Channel section bottom rails fixed to concrete including brackets, expansion bolts, etc

m

Not Priced

1999

Extra over for closed end

No

Not Priced

2000

Extra over for mitred L-intersection

No

Not Priced

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-226-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2001

2002

R

Not Priced

Toughened safety glass balustrade panels ?mm high and in suitable lengths with bottom edge grouted with non-shrinking epoxy grout mixture into bottom rail and groove in concrete, including neoprene setting blocks and butt joints between panels with polished edges and silicon sealant

m

Not Priced

Toughened safety glass trapezium shaped balustrade panel ?mm wide extreme and ?mm high with bottom edge grouted with non-shrinking epoxy grout mixture into bottom rail and groove in concrete, including neoprene setting blocks and butt joints between panels with polished edges and silicon sealant

No

Not Priced

m

Not Priced

2003

Polished edges to ?mm toughened glass at exposed ends

2004

STEEL CAT LADDERS

2005

GALVANISED STEEL CAT LADDERS Welded cat ladder ?mm wide and ?mm high overall to tankroom (plantroom?)

2007

? x ?mm Flat section stringers

kg

Not Priced

2008

Extra over for mitred L-intersection

No

Not Priced

2009

Extra over for bend across edge

No

Not Priced

2010

Extra over for bend across edge to ?mm internal radius

No

Not Priced

2011

?mm Diameter rungs ?mm long with ends welded to stringers

kg

Not Priced

? x ? x ?mm Fixing plate once (twice etc?) holed for bolt(s?) and welded on

No

Not Priced

? x ?mm Flat section bracket ?mm girth once bent across flat, once (twice etc?) holed for bolt(s?) and welded on

No

Not Priced

?mm External diameter x ?mm thick pipe rung ?mm long with ends welded to stringers

No

Not Priced

2015

?mm Expansion bolt

No

Not Priced

2016

?mm Expansion anchor with loose bolt

No

Not Priced

2012

2013

2014

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-227-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

User note 2018

Alternative to detail measurement

2019

Welded cat ladder ?mm wide and ?mm high overall to tank room (plantroom?), of ? x ?mm flat section stringers and ?mm diameter x ?mm thick pipe rungs ?mm long at approximately ?mm centres, including flat and angle section connections bolted to brickwork or concrete (bolts elsewhere)

kg

Not Priced

2020

STEEL STAIRS

2021

GALVANISED STEEL STAIRS

2022

Welded single flight stair with balustrades ? x ?mm on plan x ?mm high overall to ?

2023

?mm "Vastrap" plate continuous treads, risers and landing

kg

Not Priced

2024

? x ?mm Flat section stringers

kg

Not Priced

2025

Extra over for ramp or knee

No

Not Priced

2026

Extra over for L-intersection

No

Not Priced

2027

Hole through ?mm steel for bolt

No

Not Priced

2028

? x ?mm Flat section continuous handrails and bottom rails

kg

Not Priced

2029

Extra over for fanged end

No

Not Priced

2030

Extra over for L-intersection

No

Not Priced

2031

Extra over for T-intersection

No

Not Priced

2032

Extra over for turned down end

No

Not Priced

2033

Extra over for ramp or knee

No

Not Priced

2034

? x ? x ?mm Hollow section balusters

m

Not Priced

2035

? x ? x ?mm Hollow section standards ?mm long with top welded to underside of handrail and bottom framed through bottom rail and welded to side of stringer

No

Not Priced

?mm Expansion bolt

No

Not Priced

2036

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-228-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2037

User note

2038

Alternative to detail measurement

2039

Welded single flight stair with balustrades, ? x ?mm on plan x ?mm high overall to ?, of ?mm "Vastrap" plate continuous treads, risers and landing welded along edges to ? x ?mm flat section stringers, with one side bolted to brickwork or concrete (bolts elsewhere)

kg

Not Priced

Welded horizontal or raking balustrades for stair, of ? x ?mm flat section continuous top and bottom rails with ? x ? x ?mm hollow section standards ?mm long at approximately ?mm centres, the top of the standard welded to underside of handrail and the bottom framed through bottom rail and welded to side of stringer; the balustrades filled in with ? x ? x ?mm hollow section balusters ?mm long at approximately ?mm centres welded between top and bottom rails

m

Not Priced

No

Not Priced

50 x 2,5mm Galvanised diamond mesh covering in approximately ?m high panels tied with 1,6mm galvanised binding wire to frames



Not Priced

50 x 2,5mm Plastic coated galvanised diamond mesh covering in approximately ?m high panels tied with 1,6mm plastic covered binding wire to frames



Not Priced

? x ? x ?mm ? mesh covering in approximately ?mm high panels spot welded to frames



Not Priced

? x ?mm x ?kg/m Channel section post ?m long with ? x ? x ?mm base plate once (twice etc?) holed for bolt(s?) and welded on

kg

Not Priced

2049

?mm Diameter x ?mm thick pipe rails, posts, etc

m

Not Priced

2050

Extra over for flat closed end

No

Not Priced

2051

Extra over for mitred L-intersection

No

Not Priced

2052

Extra over for T-intersection

No

Not Priced

2040

2041

?mm Expansion bolt

2042

STEEL GATES, SCREENS, ETC

2043

GALVANISED STEEL GATES, SCREENS, ETC Welded screens and gates to ?

2045

2046

2047

2048

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-229-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2053

R

Not Priced

L-shaped cleat of ? x ?mm flat section ?mm girth once (twice etc?) holed for bolt(s?) and welded on

No

Not Priced

? x ? x ?mm Hollow section post ?m long with flat closed top end and ? x ? x ?mm base plate once (twice etc?) holed for bolt(s?) and welded on

No

Not Priced

2055

?mm Expansion bolt

No

Not Priced

2056

?mm Expansion anchor with loose bolt

No

Not Priced

2057

Single gate ? x ?mm high of ? x ?mm flat section outer frame and ? x ? x ?mm angle section inner frame welded to outer frame, filled in with "?" expanded metal panel fixed all round to inner frame with ? x ? x ?mm angle section fixing beads bolted on with and including ?mm diameter bolts at ?mm centres and fitted with a pair of suitable hinges welded to post and with lockable sliding bolt with keep in gate post

No

Not Priced

Single gate ? x ?mm high of ? x ? x ?mm hollow section frame filled in with ? x ? x ?mm welded mesh spot welded to frame and fitted with a pair of suitable hinges welded to post and with hasp and staple welded on

No

Not Priced

Single gate ? x ?mm high of ? x ? x ?mm hollow section frame and ? x ? x ?mm hollow section horizontal middle rail, filled in with ? x ? x ?mm hollow section vertical bars at ?mm centres and fitted with a pair of suitable hinges welded to post and with ears for padlock

No

Not Priced

Double gate ? x ?mm high, each leaf of ? x ? x ?mm hollow section frame and ? x ? x ?mm hollow section horizontal middle rail, filled in with ? x ? x ?mm hollow section vertical bars at ?mm centres and fitted with a pair of suitable hinges bolted to wall with and including ?mm expansion bolts, with ears for padlock and ?mm drop bolt welded on with keep in concrete

No

Not Priced

2054

2058

2059

2060

2061

SUNDRY STEELWORK

2062

SUNDRY GALVANISED STEELWORK Bolts

2064

Bolts

kg

Not Priced

2065

?mm Expansion bolt

No

Not Priced

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-230-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2066

?mm Expansion anchor with loose bolt

No

Not Priced

2067

?mm Chemical anchor with loose bolt

No

Not Priced

? x ? x ?mm Angle section bearers once (twice etc?) holed for bolt(s) at ?mm centres

kg

Not Priced

? x ? x ?mm Angle section bearers shot-pinned to concrete at ?mm centres

kg

Not Priced

? x ? x ?mm Angle section bearers with ? x ? x ?mm flat section brackets once (twice etc?) holed for bolt(s?), welded on at ?mm centres

kg

Not Priced

? x ? x ?mm Angle section brackets ?mm long, once (twice etc?) holed for bolts(s?) (and welded on?)

kg

Not Priced

2073

Type ? expanded metal strips ?mm wide, spot welded on

m

Not Priced

2074

Hole through ?mm steel for bolt

No

Not Priced

2075

?mm Expansion bolt

No

Not Priced

2076

?mm Chemical anchor with loose bolt

No

Not Priced

? x ?mm x ?kg/m Channel section corner protectors in varying lengths with ?mm diameter bent lugs each ?mm girth welded on at ?mm centres, including embedding in concrete

kg

Not Priced

? x ?mm x ?kg/m Channel section corner protectors, circular on plan to ?mm internal radius, in varying lengths with ?mm diameter bent lugs each ?mm girth welded on at ?mm centres, including embedding in concrete

kg

Not Priced

? x ?mm x ?kg/m Channel section corner protectors in varying lengths with ? x ?mm flat section bent lugs each ?mm girth welded on at ?mm centres, including embedding in concrete

kg

Not Priced

? x ?mm x ?kg/m Channel section corner protectors, circular on plan to ?mm internal radius, in varying lengths with ? x ?mm flat section bent lugs each ?mm girth welded on at ?mm centres, including embedding in concrete

kg

Not Priced

Bearers to brick linings, lintels, etc 2069

2070

2071

2072

Corner protectors 2078

2079

2080

2081

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-231-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2082

2083

2084

2085

2086

2087

R

Not Priced

? x ? x ?mm Angle section corner protectors in varying lengths with ?mm diameter bent lugs each ?mm girth welded on at ?mm centres, including embedding in concrete

kg

Not Priced

? x ? x ?mm Angle section corner protectors, circular on plan to ?mm internal radius, in varying lengths with ?mm diameter bent lugs each ?mm girth welded on at ?mm centres, including embedding in concrete

kg

Not Priced

? x ? x ?mm Angle section corner protectors in varying lengths with ? x ?mm flat section bent lugs each ?mm girth welded on at ?mm centres, including embedding in concrete

kg

Not Priced

? x ? x ?mm Angle section corner protectors, circular on plan to ?mm internal radius, in varying lengths with ? x ?mm flat section bent lugs each ?mm girth welded on at ?mm centres, including embedding in concrete

kg

Not Priced

? x ? x ?mm Angle section corner protectors in varying lengths, twice plugged at ?mm centres

kg

Not Priced

Extra over for mitred and welded L-intersection

No

Not Priced

Welded bearers to ? 2089

Welded frames to ?

2090

? x ?mm Flat section bearers

kg

Not Priced

2091

? x ?mm Flat section frames

kg

Not Priced

2092

? x ? x ?mm Angle section bearers

kg

Not Priced

2093

? x ? x ?mm Angle section frames

kg

Not Priced

2094

? x ? x ?mm Hollow section bearers

m

Not Priced

2095

? x ? x ?mm Hollow section frames

m

Not Priced

2096

?mm Diameter x ?mm thick pipe bearers

m

Not Priced

2097

?mm Diameter x ?mm thick pipe frames

m

Not Priced

2098

User note

2099

The applicable labour items from the following list are to be inserted directly after each of the foregoing items

2100

Extra over for rounded end

No

Not Priced

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-232-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2101

Extra over for flat closed end

No

Not Priced

2102

Extra over for rounded closed end

No

Not Priced

2103

Extra over for L-intersection

No

Not Priced

2104

Extra over for mitred L-intersection

No

Not Priced

2105

Extra over for T-intersection

No

Not Priced

2106

? x ? x ?mm Base plate once (twice etc?) holed for bolt(s?) and welded on

No

Not Priced

? x ? x ?mm Angle section cleat ?mm long once holed for bolt and welded on

No

Not Priced

2108

Bolts

kg

Not Priced

2109

?mm Expansion bolt

No

Not Priced

2110

?mm Expansion anchor with loose bolt

No

Not Priced

2111

?mm Chemical anchor with loose bolt

No

Not Priced

2112

Brackets etc to roof timbers etc

2113

L-shaped bracket of ? x ?mm flat section ?mm girth once bent across flat and once (twice etc?) holed for bolt(s?)

No

Not Priced

? x ? x ?mm Shoe for end of roof timber of ? x ?mm flat section ?mm girth once bent to L-shape and with two ? x ? x ?mm triangular side plates welded on, the shoe once (twice etc?) holed for bolt(s?)

No

Not Priced

L-shaped bracket of ? x ? x ?mm angle section ?mm girth mitred and welded at angle and once (twice etc?) holed for bolt(s?)

No

Not Priced

Triangular shaped bracket of ? x ? x ?mm angle section ?mm girth mitred and welded at angles and once (twice etc?) holed for bolt(s?)

No

Not Priced

Triangular shaped bracket of ? x ? x ?mm hollow section ?mm girth mitred and welded at angles and once (twice etc?) holed for bolt(s?)

No

Not Priced

? x ? x ?mm Angle section frame for ? x ?mm access panel mitred and welded at angles and once (twice etc?) holed for bolt(s?)

No

Not Priced

2107

2114

2115

2116

2117

2118

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-233-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2119

Hole through ?mm steel for bolt

No

Not Priced

2120

Bolts

kg

Not Priced

2121

?mm Expansion bolt

No

Not Priced

2122

?mm Expansion anchor with loose bolt

No

Not Priced

2123

?mm Chemical anchor with loose bolt No

Not Priced

m

Not Priced

m

Not Priced

No

Not Priced

m

Not Priced

No

Not Priced

m

Not Priced

No

Not Priced

?mm "Vastrap" plate duct covers in approximately ?mm widths and suitable lengths laid loose in frames

kg

Not Priced

? x ? x ?mm Angle section bearers welded to frames

kg

Not Priced

2124

SUNDRY STAINLESS STEELWORK

2125

? x ? x ?mm Angle section corner protectors to vertical corners, plugged on both sides

2126

SUNDRY BRASSWORK

2127

? x ?mm Flat section water bars fixed in and including groove in concrete

2128

2129

? x ? x ?mm Angle section mat surround size ? x ?mm with flat section lugs brazed on at ?mm centres, plugged

SUNDRY ALUMINIUMWORK "?" ? anodised aluminium cappings with sealed joints fixed to brickwork or concrete

2131

Type ? wall cappings ?mm wide overall

2132

Extra over for mitred and sealed L-intersection "?" ? anodised aluminium

2134

Type ? angle section corner protectors, plugged

2135

Extra over for mitred L-intersection

2136

STEEL FLOORS

2137

GALVANISED STEEL FLOORS Floor duct covers

2139

2140

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-234-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2141

Extra over for mitred and welded L-intersection

No

Not Priced

2142

? x ? x ?mm Angle section frames with ? x ?mm flat section bent lugs each ?mm girth welded on at ?mm centres including embedding in concrete

kg

Not Priced

2143

Extra over for mitred and welded L-intersection

No

Not Priced

2144

Extra over for welded T-intersection

No

Not Priced

2145

? x ? x ?mm Angle section intermediate bearers ?mm long with two ? x ? x ?mm end plates each once slot holed for bolt and welded on

kg

Not Priced

2146

? x ?mm Flat section stops spot welded to frames

m

Not Priced

2147

"?" galvanised pressed steel kerbs with sleeved joints, corner pieces and anchor lugs, embedded in concrete

m

Not Priced

"?" galvanised pressed steel kerbs with sleeved joints, corner pieces and anchor lugs, shot-pinned to concrete

m

Not Priced

2148

2149

25mm Diameter finger hole through ?mm steel

No

Not Priced

2150

?mm Expansion bolt

No

Not Priced

2151

?mm Expansion anchor with loose bolt

No

Not Priced

? x ?mm Flat section bearers holed for bolt(s) at ?mm centres

kg

Not Priced

? x ? x ?mm Angle section bearers holed for bolt(s) at ?mm centres

kg

Not Priced

? x ? x ?mm Angle section bearers ?mm long with two ? x ? x ?mm end plates each once (twice etc?) holed for bolt(s?) and welded on

kg

Not Priced

2156

? x ? x ?mm Angle section frames welded to bearers

kg

Not Priced

2157

Extra over for mitred and welded L-intersection

No

Not Priced

2158

"?" type ? (?kg/m²) mesh floors in ?mm wide panels in suitable lengths, spot welded to framing



Not Priced

Welded cat-walks in pipe ducts 2153

2154

2155

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-235-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2159

2160

2161

R

Not Priced

"?" type ? grille floors with ? x ?mm bearer bars in ?mm wide unbanded panels in suitable lengths, spot welded to framing



Not Priced

"?" type ? grille floors with ? x ?mm bearer bars in ?mm wide banded panels in suitable lengths, spot welded to framing



Not Priced

"?" type ? non-slip raised dimple grille flooring with ? x ?mm bearer bars, in ?mm wide banded panels in suitable lengths, spot welded to framing



Not Priced

m

Not Priced

2162

? x ?mm Kick flats welded on

2163

Hole through ?mm steel for bolt

No

Not Priced

2164

?mm Expansion bolt

No

Not Priced

2165

?mm Expansion anchor with loose bolt

No

Not Priced

2166

DOOR FRAMES, DOORS, WINDOWS, ETC

2167

User note

2168

It is suggested that the architect's reference number ie D1 W1, etc be inserted in brackets after each discription For clarity the various schedules may be issued together with the bills of quantities

2169

PRESSED STEEL DOOR FRAMES

2170

GALVANISED PRESSED STEEL DOOR FRAMES 1,2mm Rebated frames suitable for half brick walls 1,2mm Double rebated frames suitable for half brick walls 1,2mm Double rebated frames suitable for one brick walls 1,6mm Rebated frames suitable for one brick walls ?mm Rebated frames suitable for half brick (one brick?) walls with two 100mm brass butt hinges per door leaf ?mm Rebated frames suitable for half brick (one brick?) walls with two 100mm brass butt hinges per door leaf and two 75mm brass butt hinges per fanlight

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-236-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

?mm Double rebated frames suitable for half brick (one brick?) walls with two 100mm brass butt hinges per door leaf ?mm Double rebated frames suitable for half brick (one brick?) walls with two 100mm brass butt hinges per door leaf and two 75mm brass butt hinges per fanlight ?mm Hollow grooved frames suitable for half brick (one brick?) walls for swing doors (no hinges) ?mm Rebated frames suitable for half brick (one brick?) walls to jambs, head and threshold of openings ?mm Double rebated frames suitable for half brick (one brick?) walls to jambs, head and threshold of openings 2182

Frame for door ? x ?mm high

No

Not Priced

2183

Frame for double door ? x ?mm high

No

Not Priced

2184

Frame for door ? x ?mm high and fixed fanlight ?mm high

No

Not Priced

2185

Frame for double door ? x ?mm high and fixed fanlight ?mm high

No

Not Priced

Frame for door ? x ?mm high and fixed fanlight ?mm high with standard pressed steel glazing beads on one side of fanlight

No

Not Priced

Frame for double door ? x ?mm high and fixed fanlight ?mm high with standard pressed steel glazing beads on one side of fanlight

No

Not Priced

2188

Frame for door ? x ?mm high and hinged fanlight ?mm high

No

Not Priced

2189

Frame for double door ? x ?mm high and hinged fanlight ?mm high

No

Not Priced

No

Not Priced

2186

2187

Preparation of frames for fixing of ironmongery 2191

Arm of door closer

2192

PRESSED STEEL CUPBOARD DOOR FRAMES GALVANISED PRESSED STEEL CUPBOARD DOOR FRAMES

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-237-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2194

Standard cupboard door frames

2195

Type ? frame ? x ?mm high overall

R

Not Priced

No

Not Priced

Purpose made rebated cupboard door frames 2197

Frame for door ? x ?mm high

No

Not Priced

2198

Frame for double door ? x ?mm high

No

Not Priced

2199

Frame for door ? x ?mm high and door ?mm high above transome

No

Not Priced

Frame for double door ? x ?mm high and double door ? x ?mm high above transome

No

Not Priced

2200

PRESSED STEEL COMBINATION DOORS AND FRAMES 2202

GALVANISED PRESSED STEEL COMBINATION DOORS AND FRAMES

2203

"?" flush both sides doors

2204

Door ? x ?mm high with rebated frame suitable for half brick (one brick?) wall and with "?" mortice lock

No

Not Priced

Double door ? x ?mm high with rebated frame suitable for half brick (one brick?) wall and with "?" mortice lock

No

Not Priced

2205

PRESSED STEEL TRANSFORMER ROOM DOORS AND FRAMES 2207

GALVANISED PRESSED STEEL TRANSFORMER ROOM DOORS AND FRAMES

2208

"?" doors

2209

Type ? door ? x ?mm high with rebated frame suitable for one brick wall

No

Not Priced

Type ? double door ? x ?mm high with rebated frame suitable for one brick wall

No

Not Priced

Door ? x ?mm high with ? x ?mm high louvred ventilation panel and with rebated frame suitable for one brick wall

No

Not Priced

2210

2211

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-238-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2212

Double door ? x ?mm high, each leaf with ? x ?mm high louvred ventilation panel and with rebated frame suitable for one brick wall

2213

STEEL WINDOWS, DOORS, ETC

2214

GALVANISED STEEL WINDOWS, DOORS, ETC

R

Not Priced

No

Not Priced

Standard residential windows 2216

Standard school windows

2217

Standard industrial windows Standard ? windows with mesh burglar screens to opening sashes Standard ? windows with mesh burglar screens to fixed lights and opening sashes Standard ? windows with ? burglar bars to opening sashes

2221

Standard ? windows with flyscreens

2222

Standard ? composite windows

2223

Purpose made ? windows Purpose made ? windows with mesh burglar screens to opening sashes Purpose made ? windows with ? burglar bars to opening sashes Purpose made ? windows with ? x ?mm glazing beads

2227

Window type ?, ? x ?mm high

No

Not Priced

2228

Window as type ?, but ? x ?mm high

No

Not Priced

2229

Window ? x ?mm high with one fixed light

No

Not Priced

2230

Window ? x ?mm high with one ? hung sash

No

Not Priced

2231

Window ? x ?mm high with ? mullion(s) and ? fixed lights

No

Not Priced

Window ? x ?mm high with ? mullion(s), ? fixed light(s) and ? ? x ?mm high ? hung sash(es)

No

Not Priced

2232

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-239-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2233

2234

2235

R

Not Priced

Window ? x ?mm high with ? transome(s), ? mullion(s), ? fixed light(s) and ? ? x ?mm high ? hung sash(es)

No

Not Priced

Window ? x ?mm high with ? transome(s), ? mullion(s), ? part mullion(s) ?mm long, ? fixed light(s) and ? ? x ?mm high ? hung sash(es)

No

Not Priced

Window ? x ?mm high with one fixed light filled in with ? pressed steel louvres

No

Not Priced

Steel glazing beads, coupling transomes, coupling mullions, etc 2237

? x ?mm Standard glazing beads

m

Not Priced

2238

Standard ? section coupling mullions in varying lengths

m

Not Priced

2239

Standard ? section coupling transomes in varying lengths

m

Not Priced

2240

? x ? x ?mm ? section coupling mullions in varying lengths

m

Not Priced

2241

? x ? x ?mm ? section coupling transomes in varying lengths

m

Not Priced

? x ? x ?mm Hollow section coupling transomes and mullions in varying lengths

m

Not Priced

?mm External diameter x ?mm thick pipe coupling transomes and mullions in varying lengths

m

Not Priced

No

Not Priced

No

Not Priced

2242

2243

2244

2245

? x ? x ?mm Hollow section mullion ?mm long with ? x ? x ?mm cap and base plates each once (twice etc?) holed for bolt(s?) ?mm External diameter x ?mm thick pipe mullion ?mm long with ? x ? x ?mm cap and base plates each once (twice etc?) holed for bolt(s?)

Standard medium universal doors, sidelights, fanlights, etc Standard medium universal doors, sidelights, fanlights, etc with ? x ?mm glazing beads Purpose made medium universal doors, sidelights, fanlights, etc

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-240-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

Purpose made medium universal doors, sidelights, fanlights, etc with ? x ?mm glazing beads 2250

Sidelight type ?, ? x ?mm high

No

Not Priced

2251

Door type ?, ? x ?mm high

No

Not Priced

2252

Double door type ?, ? x ?mm high

No

Not Priced

2253

Sidelight ? x ?mm high with ? horizontal glazing bars and the bottom pane ?mm high filled in with kick plate

No

Not Priced

Door ? x ?mm high side hung to open out with ? horizontal glazing bars and lock box, the bottom pane ?mm high filled in with kick plate, the door fitted with "?" lock

No

Not Priced

Double door ? x ?mm high side hung to open out, each leaf with ? horizontal glazing bars, lock box and bottom panes ?mm high filled in with kick plate, the door fitted with two barrel bolts and "?" lock

No

Not Priced

Door and sidelight ? x ?mm high overall, the sidelight ? x ?mm high with ? horizontal glazing bars and bottom pane ?mm high filled in with kick plate and the door ? x ?mm high side hung to open out with ? horizontal glazing bars, lock box and bottom pane ?mm high filled in with kick plate, the door fitted with "?" lock

No

Not Priced

No

Not Priced

2254

2255

2256

Louvre panels with type ? horizontal louvres, screwed into steel window frames 2258

Panel ? x ?mm high

2259

ALUMINIUM WINDOWS, DOORS, ETC

2260

ALUMINIUM CASEMENT WINDOWS

2261

"?" OUTWARD OPENING ALUMINIUM CASEMENT WINDOWS

2262

"?" INWARD OPENING ALUMINIUM CASEMENT WINDOWS

2263

"?" INWARD OPENING ALUMINIUM TILT AND TURN WINDOWS

2264

"?" INWARD OPENING ALUMINIUM CASEMENT WINDOWS WITH ALUMINIUM SHUTTERS

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-241-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2265

Note

2266

Refer to attached window schedules for details of windows

2267

? anodised casement windows as per "?" system, complete with subframes, ironmongery, glass, sealing, etc and fixing to brickwork or concrete

2268

Powder coated casement window units as per "?" system, complete with subframes, ironmongery, glass, sealing, etc and fixing to brickwork or concrete

2269

? anodised tilt and turn window units as per "?" system complete with subframes, ironmongery, glass, sealing, etc and fixing to brickwork or concrete

2270

Powder coated tilt and turn window units as per "?" system complete with subframes, ironmongery, glass, sealing, etc and fixing to brickwork or concrete

2271

? anodised casement windows with external aluminium shutters as per "?" system complete with subframes, ironmongery, glass, sealing, etc and fixing to brickwork or concrete

2272

Powder coated casement windows with external aluminium shutters as per "?" system complete with subframes, ironmongery, glass, sealing, etc and fixing to brickwork or concrete

2273

Standard window type ?, ? x ?mm high

No

Not Priced

2274

Purpose made window, ? x ?mm high

No

Not Priced

2275

ALUMINIUM SLIDING WINDOWS

2276

"?" ALUMINIUM VERTICAL SLIDING WINDOWS

2277

"?" ALUMINIUM HORIZONTAL SLIDING WINDOW UNITS

2278

? anodised vertical sliding window units as per "?" system, complete with subframes, ironmongery, glass, sealing, etc and fixing to brickwork or concrete

2279

Powder coated vertical sliding window units as per "?" system, complete with subframes, ironmongery, glass, sealing, etc and fixing to brickwork or concrete

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-242-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2280

? anodised horizontal sliding window units as per "?" system, complete with subframes, ironmongery, glass, sealing, etc and fixing to brickwork or concrete

2281

Powder coated horizontal sliding window units as per "?" system, complete with subframes, ironmongery, glass, sealing, etc and fixing to brickwork or concrete

2282

Standard window type ?, ? x ?mm high

No

Not Priced

2283

Purpose made window, ? x ?mm high

No

Not Priced

2284

ALUMINIUM SLIDING DOORS

2285

? anodised sliding doors as per "?" system, complete with subframes, ironmongery, glass, sealing, etc and fixing to brickwork or concrete

2286

Powder coated sliding doors as per "?" system, complete with subframes, ironmongery, glass, sealing, etc and fixing to brickwork or concrete

2287

Standard door type ?, ? x ?mm high

No

Not Priced

2288

Purpose made door, ? x ?mm high

No

Not Priced

2289

ALUMINIUM SHOPFRONTS

2290

? anodised shopfronts as per "?" system complete with subframes, ironmongery, glass, sealing, etc and fixing to brickwork or concrete

2291

Powder coated shopfronts as per "?" system complete with subframes, ironmongery, glass, sealing, etc and fixing to brickwork or concrete

2292

Purpose made shopfront, ? x ?mm high

No

Not Priced

2293

Purpose made shopfront, ? x ?mm high with one double door ? x ?mm high

No

Not Priced

2294

FRAMELESS SHOPFRONTS AND LOBBY SCREENS

2295

SUPPLEMENTARY PREAMBLES

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-243-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2296

Construction

2297

Shopfronts, lobby screens, etc shall be of toughened glass "frameless" construction with natural anodised aluminium top and bottom rails, (and reinforced with ?mm wide toughened glass fins behind butt joints including brackets at top and bottom?), with patch fittings and with glass edges at butt joints polished and sealed with silicon sealant

2298

Fixing

2299

Top rails of shopfronts, lobby screens, etc and doors are fixed to underside of suspended ceilings below concrete slabs. Prices are to include for necessary extension brackets. Distances between concrete slabs and suspended ceilings are stated in the descriptions

2300

Frameless structural glass (no reinforcing ribs) shopfronts and doors with natural anodised aluminium top and bottom rails, with polished stainless steel patch fittings, approved floor spring hinges and locking bolts (pull handles elsewhere)

2301

Shopfront ?mm wide x ?mm high (?mm below concrete slab)

No

Not Priced

Shopfront ?mm wide x ?mm high with single swing double door ?mm wide x ?mm high (?mm below concrete slab)

No

Not Priced

2302

2303

Frameless structural glass (no reinforcing ribs) lobby screens and doors with natural anodised aluminium top and bottom rails, with polished stainless steel patch fittings, approved floor spring hinges and locking bolts (pull handles elsewhere)

2304

Lobby screen ?mm wide x ?mm high (?mm below concrete slab)

No

Not Priced

Lobby single swing double door ?mm wide x ?mm high (?mm below concrete slab)

No

Not Priced

Lobby screen ?mm wide x ?mm high with single swing double door ?mm wide x ?mm high (?mm below concrete slab)

No

Not Priced

Lobby screen ?mm wide x ?mm high with double swing double door ?mm wide x ?mm high (?mm below concrete slab)

No

Not Priced

2305

2306

2307

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-244-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2308

Lobby screen ?mm wide x ?mm high with automatic sliding double door ?mm wide x ?mm high (?mm below concrete slab)

R

Not Priced

No

Not Priced

Pairs

Not Priced

2309

?mm U-shaped pull handles (PC R ? per pair)

2310

Door stop (PC R ?), plugged

No

Not Priced

2311

Preparation only of door and frame for magnetic lock (magnetic lock supplied and fitted by others)

No

Not Priced

No

Not Priced

2312

ALUMINIUM CURTAIN WALLS

2313

? anodised curtain walls as per "?" system complete with subframes, ironmongery, glass, sealing, etc and fixing to brickwork or concrete

2314

Powder coated curtain walls as per "?" system complete with subframes, ironmongery, glass, sealing, etc and fixing to brickwork or concrete

2315

Purpose made curtain wall ? x ?mm high

2316

ALUMINIUM SLIDING FOLDING DOORS

2317

? anodised sliding folding doors as per "?" system complete with subframes, ironmongery, glass, sealing, etc and fixing to brickwork or concrete

2318

Powder coated sliding folding doors as per "?" system complete with subframes, ironmongery, glass, sealing, etc and fixing to brickwork or concrete

2319

Standard sliding folding door type ?, ? x ?m high

No

Not Priced

2320

Purpose made sliding folding door, ? x ?mm high

No

Not Priced

2321

ALUMINIUM INSECT SCREENS

2322

? anodised insect screens as per "?" system, complete with ironmongery etc and fixing to brickwork or concrete

2323

Powder coated insect screens as per "?" system, complete with ironmongery etc and fixing to brickwork or concrete

2324

Standard screen type ?, ? x ?mm high

No

Not Priced

2325

Purpose made screen, ? x ?mm high

No

Not Priced

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-245-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2326

ALLUMINIUM LOUVRE UNITS

2327

? ANODISED HORIZONTAL ALUMINIUM LOUVRE UNITS

2328

POWDER COATED HORIZONTAL ALUMINIUM LOUVRE UNITS

2329

"?" fixed louvre units fixed to brickwork or concrete

2330

"?" fixed louvre units screwed into timber (steel etc?) frames

2331

Standard louvre unit type ?, ? x ?mm high

No

Not Priced

2332

Purpose made louvre unit for ? x ?mm high opening

No

Not Priced

2333

? ANODISED LOUVRE UNITS WITH GLASS LOUVRES

2334

POWDER COATED LOUVRE UNITS WITH GLASS LOUVRES

2335

"?" louvre units including ?mm clear float glass horizontal louvres, fixed to brickwork or concrete

2336

"?" louvre units including ?mm clear float glass horizontal louvres, screwed into timber (steel etc?) frames

2337

Standard louvre unit type ?, ? x ?mm high

No

Not Priced

2338

Purpose made louvre unit for ? x ?mm high opening

No

Not Priced

2339

"?" louvre units including ?mm clear float glass vertical louvres, fixed to brickwork or concrete

2340

"?" louvre units including ?mm clear float glass vertical louvres, screwed into timber (steel etc?) frames

2341

Standard louvre unit type ?, ? x ?mm high

No

Not Priced

2342

Purpose made louvre unit for ? x ?mm high opening

No

Not Priced

PRESSED STEEL GARAGE DOORS 2344

PRESSED STEEL POWDER COATED GARAGE DOORS

2345

GALVANISED PRESSED STEEL GARAGE DOORS

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-246-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2346

POWDER COATED ALUMINIUM GARAGE DOORS

2347

"?" tip-up doors fixed to brickwork or concrete

2348

Tip-up door for ? x ?mm high opening

2349

"?" Sliding panel doors fixed to brickwork or concrete

2350

2351

R

Not Priced

No

Not Priced

"Slideover" hand operated panel door for ? x ?mm high opening

No

Not Priced

"Slideover" electrically operated panel door for ? x ?mm high opening, including electrical connection and commissioning (electrical isolator elsewhere)

No

Not Priced

STEEL ROLLER SHUTTERS ETC 2353

"?" galvanised steel roller shutters with 76mm slats (18kg/m²), fixed to brickwork or concrete

2354

"?" galvanised steel powder coated roller shutters with 76mm slats (18kg/m²), fixed to brickwork or concrete

2355

Manual push-up slatted roller shutter for ? x ?mm high opening

No

Not Priced

Chain operated slatted roller shutter for ? x ?mm high opening

No

Not Priced

Soffit fixed crank operated slatted roller shutter for ? x ?mm high opening

No

Not Priced

Side fixed crank operated slatted roller shutter for ? x ?mm high opening

No

Not Priced

Electrically operated slatted roller shutter for ? x ?mm high opening, including electrical connection and commissioning (electrical isolator elsewhere)

No

Not Priced

Manual push up class B fire resistant slatted roller shutter for ? x ?mm high opening, with fusable link

No

Not Priced

No

Not Priced

2356

2357

2358

2359

2360

2361

"?" roller grilles fixed to brickwork or concrete

2362

"?" powder coated roller grilles fixed to brickwork or concrete

2363

? pattern manual push-up (chain operated?, crank operated?) roller grille for ? x ?mm high opening

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-247-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2364

? pattern electrically operated roller grille for ? x ?mm high opening, including electrical connection and commissioning (electrical isolator elsewhere)

R

Not Priced

No

Not Priced

2365

STEEL RECORDROOM AND STRONGROOM DOORS, VENTILATORS, ETC

2366

"?" recordroom (strongroom?) doors etc suitable for 230mm walls fixed to brickwork or concrete

2367

Single ended recordroom (strongroom?) ventilator

No

Not Priced

2368

Double ended recordroom (strongroom?) ventilator

No

Not Priced

2369

"?" recordroom (strongroom?) door and frame ? x ?mm high overall with a mass of ?kg

No

Not Priced

"?" anti-explosive strongroom door and frame ? x ?mm high overall with a mass of ?kg

No

Not Priced

No

Not Priced

2370

2371

SECURITY PAYROLL WINDOWS

2372

"?" security payroll windows suitable for ?mm walls, fixed to brickwork or concrete

2373

Window ? x ?mm high

ROOF LIGHTS 2375

"?" type roof lights

2376

Single skin dome to suit ? x ?mm opening, of 5mm thick U-95 tinted acrylic perspex with aluminium kerb, bolted to concrete with and including expansion bolts

No

Not Priced

Double skin dome to suit ? x ?mm opening, of 5mm thick clear acrylic perspex inner skin and 5mm thick U-95 tinted acrylic perspex outer skin with aluminium kerb, bolted to concrete with and including expansion bolts

No

Not Priced

Low rise single skin barrel vault to suit ? x ?mm opening, of 5mm thick ? tinted acrylic perspex with ? anodised aluminium framing, glazing bars, etc, bolted to concrete with and including expansion bolts

No

Not Priced

2377

2378

2379

SHOWER CUBICLE PANELS AND DOORS

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-248-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

"?" ? anodised (powder coated?) aluminium shower cubicle panels and doors with frames, sliding gear, pivot hinges, cleats, stops, etc and ?mm toughened clear safety glass, plugged to tiled walls and sealed with silicone sealant 2381

Fixed panel ? x ?mm high

No

Not Priced

2382

Sliding door ? x ?mm high

No

Not Priced

2383

Sliding door in ? leaves, ? x ?mm high overall

No

Not Priced

2384

Swing door ? x ?mm high

No

Not Priced

2385

Pivot door ? x ?mm high

No

Not Priced

2386

Pivot door and fixed side panel ? x ?mm high overall with door ?mm wide

No

Not Priced

2387

Type ? door knob

No

Not Priced

2388

Type ? door handle

No

Not Priced

2389

Frameless ?mm toughened clear glass shower cubicle panels and doors, including tile stops, patch fittings, sealing strips, etc, plugged to tiled walls and sealed with silicone sealant

2390

Fixed panel ? x ?mm high

No

Not Priced

2391

Swing door ? x ?mm high

No

Not Priced

2392

In-line fixed panel and swing door ? x ?mm high overall with door ?mm wide

No

Not Priced

Cubicle L-shaped on plan, one leg ?mm wide x ?mm high with fixed panel and other leg ?mm wide overall x ?mm high with fixed panel and ?mm wide swing door

No

Not Priced

2394

Type ? chromium plated (brass? stainless steel?) door knob

No

Not Priced

2395

Type ? chromium plated (brass? stainless steel?) door handle

No

Not Priced

2393

2396

Clear shielding

2397

Protection of clear glass with clear shielding



Not Priced

2398

Protection of sandblasted glass with clear shielding including protection of adjacent work



Not Priced

Carried forward Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-249-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2399

Sandblasting

2400

Sandblasting to glass (even finish)



Not Priced

2401

Sandblasting pattern ? x ?mm high

No

Not Priced

Carried to summary Bill No 16 Metalwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-250-

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

2402

BILL NO ?

2403

PLASTERING

2404

SUPPLEMENTARY PREAMBLES

2405

User Note

2406

The following preambles are to be included only when specifically required by the principal agent

2407

GRANOLITHIC

2408

Method

2409

The method to be used shall be either the monolithic method or the bonded method

2410

Preparation

2411

For granolithic applied monolithically, the concrete floor shall be swept clean after bleeding of the concrete has ceased and the slab has begun to stiffen; any remaining bleed water shall be removed and the granolithic applied immediately thereafter. For granolithic to be bonded to the floor slab after it has hardened, the slab surface shall be hacked (preferably by mechanical means) until all laitance, dirt, oil, etc is dislodged and swept clean of all loose matter. The slab shall then be wetted and kept damp for at least six hours before applying the granolithic

2412

Mix

2413

Granolithic shall attain a compressive strength of at least 41MPa. The coarse aggregate shall comply with SANS 1083 and shall generally be capable of passing a 10mm mesh sieve. Where the thickness of the granolithic exceeds 25mm, the size of the coarse aggregate shall be increased to the maximum size compatible with the thickness of the granolithic

2414

Panels

2415

Granolithic shall be laid in panels not exceeding 14m² for monolithic finishes, not exceeding 9,5m² for bonded finishes and not exceeding 6m² for all external granolithic. Wherever possible, panels shall be square but at no time should the length of the panel exceed 1,5 times its width

Carried forward Bill No 17 Plastering ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-251-

Quantity

Rate

Amount

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2416

Where possible joints between panels shall be positioned over joints in the floor slab and shall be at least 3mm wide through the full thickness of the finish, separated by strips of wood or fibreboard and finished with V-joints

2417

Laying

2418

Monolithic granolithic shall be applied to the partially set slab and thoroughly compacted and lightly wood floated to the required levels

2419

Bonded granolithic shall be applied to the slab after applying a 1:1 sand-and-cement slurry brushed over the surface and allowed to partially set before applying the granolithic. The granolithic shall be throughly compacted and lightly wood floated to the required levels

2420

After wood floating, the monolithic and bonded granolithic shall remain undisturbed until bleeding has ceased and the surface has stiffened. Any remaining bleed water and laitance shall then be removed and the surface steel trowelled or power floated

2421

Curing, seasoning and protection

2422

Granolithic shall be covered with clean hessian with waterproof building foil over and kept wet for at least seven days after laying

2423

Colour

2424

Coloured granolithic shall be tinted with an approved colouring pigment mixed into a true and even colour

2425

SCREEDS

2426

Screeds wood floated, on concrete

2427

Screeds steel trowelled, on concrete

2428

?:? Cement plaster screeds wood floated, on concrete

2429

?:? Cement plaster screeds wood floated for tiles, on concrete

2430

?:? Cement plaster screeds steel trowelled, on concrete

2431

Screeds with compressive strength of ? MPa steel trowelled, on concrete

Carried forward Bill No 17 Plastering ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-252-

R

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2432

CEMENT RENDER

2433

User Note:

2434

Cement render is a suitable finish to floors of store rooms etc where granolithic is not specifically required

2435

Untinted 1:3 cement render steel trowelled, on concrete

2436

GRANOLITHIC

2437

Untinted granolithic, on concrete

2438

Untinted granolithic waterproofed with "?" waterproofing additive, on concrete

2439

Untinted granolithic hardened with ? kg of "?" hardener per 50kg of cement, on concrete

2440

Black (Green etc?) granolithic, on concrete

2441

?mm Thick on floors and landings



Not Priced

2442

?mm Thick on floors in sunk panels



Not Priced

2443

?mm Thick on floors in raised panels



Not Priced

2444

?mm Thick on floors on waterproofing membrane



Not Priced

2445

?mm Thick on floors over underfloor heating coils



Not Priced

2446

Average ?mm thick on floors with upper surface to falls



Not Priced

2447

Average ?mm thick on floors with upper surface to falls and currents



Not Priced

2448

Average ?mm thick on roofs with upper surface to falls



Not Priced

2449

Average ?mm thick on roofs with upper surface to falls and currents



Not Priced

2450

?mm Thick on treads and risers of stairs



Not Priced

2451

?mm Thick on treads and risers of stairs including reedings



Not Priced

2452

?mm Thick on narrow widths



Not Priced

2453

? x ?mm Deep segmental channels formed in finish

m

Not Priced

Carried forward Bill No 17 Plastering ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-253-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2454

?mm Thick on top and side(s) of kerbs ?mm girth

m

Not Priced

2455

? x ?mm Triangular fiillets against walls, kerbs, etc

m

Not Priced

2456

Skirtings ?mm high

m

Not Priced

2457

Skirtings ?mm high stepped over treads and risers

m

Not Priced

2458

Raking skirtings average ?mm high over treads and risers

m

Not Priced

2459

Sundries

2460

Fixing in position steel underfloor cable channels ? x ?mm deep overall including levelling by means of wedges and mortar packings, securing in position whilst screeding and working screed around and under channels and junction boxes to finish flush with floor finish (channels supplied and placed roughly in position by others)

m

Not Priced

2461

INTERNAL PLASTER

2462

Compo plaster steel trowelled, on brickwork

2463

Compo plaster steel trowelled, on concrete

2464

Cement plaster wood floated for tiles, on brickwork

2465

Cement plaster wood floated for tiles, on concrete

2466

Cement plaster steel trowelled, on brickwork

2467

Cement plaster steel trowelled, on concrete

2468

Cement plaster rendering coat with gypsum skim plaster finishing coat, on brickwork

2469

Cement plaster rendering coat with gypsum skim plaster finishing coat, on concrete

2470

Rough-cast plaster, on brickwork

2471

Rough-cast plaster, on concrete

2472

Fine rough-cast plaster, on brickwork

2473

Fine rough-cast plaster, on concrete

2474

EXTERNAL PLASTER

Carried forward Bill No 17 Plastering ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-254-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2475

Compo plaster wood floated, on brickwork

2476

Compo plaster wood floated, on concrete

2477

Cement plaster wood floated for tiles, on brickwork

2478

Cement plaster wood floated for tiles, on concrete

2479

Cement plaster wood floated, on brickwork

2480

Cement plaster wood floated, on concrete

2481

Rough-cast plaster, on brickwork

2482

Rough-cast plaster, on concrete

2483

Fine rough-cast plaster, on brickwork

2484

Fine rough-cast plaster, on concrete

2485

Coloured cement plaster tinted ? with approved colouring pigment mixed into the plaster in the proportion of ? kg "?" pigment per pocket of cement, of uniform appearance and consistent colour throughout, wood floated, on brickwork (on concrete?) (no paint or other decoration)

2486

On walls



Not Priced

2487

On walls in sunk panels



Not Priced

2488

On walls in raised panels



Not Priced

2489

On walls between timber grounds to receive panelling (area of grounds not deducted)



Not Priced

2490

On circular walls



Not Priced

2491

On projecting and isolated columns



Not Priced

2492

On ceilings



Not Priced

2493

On raking soffits of stairs



Not Priced

2494

On projecting and isolated beams



Not Priced

2495

On narrow widths



Not Priced

2496

On side(s) and front edge of surrounds ?mm girth

m

Not Priced

Carried forward Bill No 17 Plastering ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-255-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2497

R

Not Priced

On sloping top, front edge and projecting soffit of sills ?mm girth

m

Not Priced

On sloping top, edge(s) and projecting soffit(s) of copings ?mm girth

m

Not Priced

2499

Horizontal mouldings ? x ?mm projection and ?mm girth

m

Not Priced

2500

User note

2501

The following two items are applicable only to mouldings exceeding 300mm girth

2502

End to moulding ?mm girth

No

Not Priced

2503

Mitre to moulding ?mm girth

No

Not Priced

2504

TERRAZZO

2505

User note

2506

Terrazzo in-situ finish consists of a sand-cement backing coat with a 12mm thick finishing coat of coarse marble aggregate mixed with white cement. Terrazzo to floors etc is normally polished to a smooth surface and that to walls etc brushed to expose the marble aggregate

2498

To prevent cracking terrazzo surfaces are subdivided into panels with brass or ebony strips Due to its high cost and tendency to show cracks after a period of time, even where precautions to prevent this have been taken, it is now very seldom used and the skills required have largely disappeared Terrazzo work is to be given in accordance with the aforegoing principles 2507

SPECIALISED PLASTER TYPE WALL COATINGS

2508

All specialised plaster type wall coatings are to be executed in strict accordance with the manufacturer's instructions

Carried forward Bill No 17 Plastering ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-256-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2509

User note

2510

The range of products and types of finishes offered by most of the manufacturers are numerous and users are advised to consult the relevant brochures and obtain the specific specifications for their applications from the principal agent. The headings hereunder are therefore given as a guideline only

2511

15mm Thick cement based resin bonded, self curing, pre-pigmented, plasticised, ready mixed plaster applied in a single coat with a spray gun on fair faced brickwork

2512

2mm Thick resin bonded plaster finish applied in a single coat with a steel trowel and floated with a float-trowel, on plaster (plaster elsewhere), including priming

2513

?mm "Gammaplast" cementitious pre-pigmented acrylic plasticised textured plaster finish applied in two operations with smooth finish (3,2mm stone finish?) sealed with two coats pure acrylic sealer as recommended by the manufacturer, on brickwork (on concrete?)

2514

On walls



Not Priced

2515

On circular walls



Not Priced

2516

On projecting and isolated columns



Not Priced

2517

On ceilings



Not Priced

2518

On raking soffits of stairs



Not Priced

2519

On projecting and isolated beams



Not Priced

2520

On narrow widths



Not Priced

2521

AIR GRATINGS

2522

235 x 157mm Cast plaster or white plastic plain pattern air grating fixed flush with plaster face

No

Not Priced

2523

METAL LATHING

2524

12 x 40mm Expanded steel mesh lathing with 1,6 x 2,5mm strands (mass 4,1kg/m²)

2525

"Mentex 82" steel lathing

Carried forward Bill No 17 Plastering ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-257-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2526

Black painted "Mentlath 213" steel lathing

2527

Sheets fixed to timber brandering to ceilings (brandering elsewhere)

2528

2529

R

Not Priced



Not Priced

Strips ?mm wide fixed at 200mm centres along both edges to brickwork or concrete with hardened steel clout headed nails

m

Not Priced

Strips ?mm girth bent longitudinally to shape and fixed at 200mm centres along both edges to brickwork or concrete with hardened steel clout headed nails

m

Not Priced

2530

CORNER PROTECTORS, DIVIDING STRIPS, ETC

2531

"Mentex Plaster Stop" galvanised steel edge strips fixed to brickwork or concrete

m

Not Priced

"Mentex Angle Bead" galvanised steel corner protectors fixed to brickwork or concrete

m

Not Priced

? x ?mm Flat section brass dividing strips between differing floor finishes

m

Not Priced

? x ? x ?mm L-section brass dividing strips between differing floor finishes

m

Not Priced

2532

2533

2534

Carried to summary Bill No 17 Plastering ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-258-

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

4726

BILL NO ?

4727

TILING

4728

SUPPLEMENTARY PREAMBLES

4729

Fixing

4730

Unless described as "fixed with adhesive to plaster (plaster elsewhere)" descriptions of tiling on brick or concrete walls, columns, etc shall be deemed to include 1:4 cement plaster backing and descriptions of tiling on concrete floors etc shall be deemed to include 1:3 plaster bedding

4731

Tiling described as "fixed with adhesive on power floated concrete" shall be deemed to include for approved tiling key-coat

4732

Ceramic, porcelain, marble and granite tiles are to be fixed and grouted with suitable adhesives and grouts from the "Tal Professional" ("Ceresit Tylon"?) range of products as recommended by the manufacturer of the tiles

4733

WALL TILING

4734

200 x 200 x 5mm White matt (glazed?) ceramic tiles on brickwork including cement plaster backing

4735

200 x 200 x 5mm White matt (glazed?) ceramic tiles on concrete including cement plaster backing

4736

200 x 200 x 5mm White matt (glazed?) ceramic tiles fixed with adhesive to plaster (plaster elsewhere)

4737

? x ? x ?mm ? colour code ? matt (glazed?) ceramic tiles fixed with adhesive to plaster (plaster elsewhere) and flush pointed with tinted grout

4738

? x ? x ?mm ? Ceramic tiles (PC R ?/m²) fixed with adhesive to plaster (plaster elsewhere) and flush pointed with tinted grout

4739

? x ? x ?mm ? colour code ? unpolished (polished?) porcelain tiles fixed with adhesive to plaster (plaster elsewhere) and flush pointed with tinted grout

Carried forward Bill No 18 Tiling ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-259-

Quantity

Rate

Amount

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4740

? x ? x ?mm Porcelain tiles (PC R ?/m²) fixed with adhesive to plaster (plaster elsewhere) and flush pointed with tinted grout

4741

On walls



Not Priced

4742

On walls circular to exceeding 300mm radius



Not Priced

4743

On walls circular to not exceeding 300mm radius



Not Priced

4744

On walls in isolated panels, splashbacks, etc



Not Priced

4745

On walls to diagonal pattern



Not Priced

4746

On projecting and isolated columns



Not Priced

4747

On piers and pilasters



Not Priced

4748

On narrow widths



Not Priced

4749

On narrow widths to diagonal pattern



Not Priced

4750

On sills ?mm wide of bullnose tiles laid flat

m

Not Priced

4751

Circular cutting

m

Not Priced

4752

Fair exposed cutting and fitting around rectangular handrail, baluster, etc not exceeding 300mm girth

No

Not Priced

Fair exposed cutting and fitting around pipe not exceeding 100mm internal diameter

No

Not Priced

Fair exposed cutting and fitting around pipe exceeding 100mm and not exceeding 150mm internal diameter

No

Not Priced

4753

4754

4755

FLOOR TILING

4756

User note

4757

Waterproof grout is normally used in showers, on balconies, etc. Epoxy grout is used in kitchens, butcheries, etc, where floors are frequently washed with detergents

4758

? x ? x ?mm ? colour code ? matt (glazed?) ceramic floor tiles on ?mm bedding on concrete and flush pointed with tinted (waterproof?) grout

Carried forward Bill No 18 Tiling ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-260-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4759

? x ? x ?mm ? colour code ? matt (glazed?) ceramic floor tiles on ?mm bedding on concrete and flush pointed with epoxy grout

4760

? x ? x ?mm ? colour code ? matt (glazed?) ceramic floor tiles fixed with adhesive to screed (screed elsewhere) and flush pointed with tinted (waterproof?) grout

4761

? x ? x ?mm ? colour code ? matt (glazed?) ceramic floor tiles fixed with adhesive to screed (screed elsewhere) and flush pointed with epoxy grout

4762

? x ? x ?mm ? colour code ? matt (glazed?) ceramic floor tiles fixed with adhesive to power floated concrete and flush pointed with tinted (waterproof?) grout

4763

? x ? x ?mm ? colour code ? unpolished (polished?) porcelain floor tiles fixed with adhesive to screed (screed elsewhere) and flush pointed with tinted (waterproof?) grout

4764

? x ? x ?mm ? colour code ? unpolished (polished?) porcelain floor tiles fixed with adhesive to power floated concrete and flush pointed with tinted (waterproof?) grout

4765

? x ? x ?mm ? ceramic (porcelain?) floor tiles (PC R ?/m²) fixed with adhesive to screed (screed elsewhere) and flush pointed with (waterproof?) grout

4766

? x ? x ?mm ? ceramic (porcelain?) floor tiles (PC R ?/m²) fixed with adhesive to power floated concrete and flush pointed with (waterproof?) grout

4767

? x ? x ?mm ? Polished marble (granite?) tiles fixed with adhesive to screed (screed elsewhere) and flush pointed with tinted (waterproof?) grout

4768

On floors and landings



Not Priced

4769

On narrow widths



Not Priced

4770

Circular cutting

m

Not Priced

4771

On margins ?mm wide of tiles laid to stretcher pattern

m

Not Priced

4772

On thresholds ?mm wide of (cut?) tiles laid flat

m

Not Priced

4773

On thresholds ?mm wide of (cut?) tiles laid sloping

m

Not Priced

4774

On risers ?mm high (of cut tiles?)

m

Not Priced

Carried forward Bill No 18 Tiling ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-261-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4775

On treads ?mm high (of cut tiles?)

m

Not Priced

4776

On treads ?mm wide of bullnose tiles

m

Not Priced

4777

On treads ?mm wide of bullnose tiles with cut tiles behind

m

Not Priced

4778

On raking and stepped outer edges of stairs ?mm wide extreme

m

Not Priced

4779

Skirting ?mm high (of cut tiles?)

m

Not Priced

4780

Sloping skirting ?mm high extreme including stepped cutting over treads and risers

m

Not Priced

4781

Skirting ?mm high of ? skirting tiles

m

Not Priced

4782

Skirting ?mm high of ? skirting tiles stepped over treads and risers

m

Not Priced

4783

Extra over for end tile

No

Not Priced

4784

Extra over for internal corner tile

No

Not Priced

4785

Extra over for external corner tile

No

Not Priced

4786

Fair exposed cutting and fitting around rectangular handrail, baluster, etc not exceeding 300mm girth

No

Not Priced

Fair exposed cutting and fitting around pipe not exceeding 100mm internal diameter

No

Not Priced

Fair exposed cutting and fitting around pipe exceeding 100mm and not exceeding 150mm internal diameter

No

Not Priced

m

Not Priced

4787

4788

4789

CHANNELS

4790

"?" white glazed fireclay block channels bedded and jointed in 1:3 cement mortar and pointed with flush joints in 1:3 white cement grout

4791

? x ?mm Block channels

4792

Extra over block channels for:

4793

Fair end

No

Not Priced

4794

Stopped end

No

Not Priced

4795

Angle

No

Not Priced

Carried forward Bill No 18 Tiling ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-262-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4796

T-intersection

No

Not Priced

4797

X-intersection

No

Not Priced

4798

Outlet

No

Not Priced

4799

Stopped end with outlet

No

Not Priced

4800

SUNDRIES

4801

? x ?mm Access panel of 6mm tempered hardboard with ? ceramic tiles fixed with adhesive, fitted flush with tile face and screwed with ? chromium plated dome-capped screws to and including 38 x 38mm sawn softwood framing plugged to wall

No

Not Priced

4802

"?" white glazed ceramic soap dishes etc

4803

"?" colour glazed ceramic soap dishes etc

4804

? x ?mm Type ? semi-recessed toilet paper holder

No

Not Priced

4805

? x ?mm Type ? recessed toilet paper holder

No

Not Priced

4806

? x ?mm Type ? semi-recessed soap dish

No

Not Priced

4807

? x ?mm Type ? recessed soap dish

No

Not Priced

4808

? x ?mm Type ? recessed soap dish with hand grip

No

Not Priced

4809

? x ?mm Type ? ash tray

No

Not Priced

4810

? x ?mm Type ? foot rest

No

Not Priced

4811

Aluminium (Brass?) dividing strips

4812

? x ?mm Flat section dividing strips between tiles

m

Not Priced

4813

? x ? x ?mm L-section dividing strips between tiles

m

Not Priced

4814

Aluminium (Stainless steel? Brass?) corner protectors, stair nosings, expansion joint strips, etc

4815

Type ? corner protectors

m

Not Priced

4816

Type ? stair nosings

m

Not Priced

4817

Type ? single expansion joint strips with vinyl (rubber?) inlay

m

Not Priced

Carried forward Bill No 18 Tiling ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-263-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4818

Type ? double expansion joint strips with vinyl (rubber?) inlay

Carried to summary Bill No 18 Tiling ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-264-

R

m

Not Priced

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

3946

BILL NO ?

3947

PLUMBING AND DRAINAGE (PROVISIONAL?)

3948

SUPPLEMENTARY PREAMBLES

3949

Wire gratings

Quantity

Rate

Amount

Descriptions of gutter outlets etc shall be deemed to include wire balloon gratings 3951

Stormwater channels

3952

Descriptions of channels shall be deemed to include necessary excavation, surface preparation, compaction, etc, and disposal of surplus material on site

3953

French drains

3954

Descriptions of french drains shall be deemed to include excavation, stone filling graded from 300mm diameter at bottom to 75mm diameter at top, "?" geofabric filter blanket over stone, 300mm earthfilling over and disposal of surplus material on site

3955

Septic tanks Descriptions of proprietary type septic tanks shall be deemed to include excavation, bedding and jointing, concrete base slabs, jointing to drains and backfilling, compaction, etc all in accordance with the manufacturer's instructions and disposal of surplus material on site

3957

Stainless steel basins, sinks, wash troughs, urinals, etc

3958

Stainless steel for economy basins, domestic sinks and worktops shall be Type 430 (17/0) Stainless steel for urinals, basins, quality sinks, wash troughs, institutional equipment, etc shall be Type 304 (18/8) Stainless steel for laboratory sinks, photographic equipment, etc shall be Type 316 (18/8) Units shall have standard aprons on all exposed edges and tiling keys against walls where applicable

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-265-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 3959

Sealing of edges

3960

Outer edges of sinks, basins, baths, urinals, etc are to be sealed against adjacent surfaces with approved silicone

3961

uPVC pipes and fittings

R

Not Priced

R

Not Priced

Sewer and drainage pipes and fittings shall be jointed and sealed with butyl rubber rings Soil, waste and vent pipes and fittings shall be solvent weld jointed or sealed with butyl rubber rings 3963

uPVC pressure pipes and fittings Pipes of 50mm diameter and smaller shall be plain ended with solvent welded uPVC loose sockets and fittings Pipes of 63mm diameter and greater shall have sockets and spigots with push-in type integral rubber ring joints. Bends shall be uPVC and all other fittings shall be cast iron, all with similar push-in type joints

3965

High density polyethylene (HDPe) pipes and fittings

3966

Pipes shall be type IV and of the class specified with "Plasson" or "Alprene" compression fittings

3967

"Polycop" polypropylene pipes Polypropylene pipes 54mm diameter and smaller shall be seamless copper coloured Class 16 pipes jointed with "Fast-fuse" heat welded thermoplastic or where so described "Polylock" compression fittings Pipes shall be firmly fixed to walls, etc with coloured nylon snap-in pipe clips with provision for accommodating thermal movement and jointed and fixed strictly in accordance with the manufacturer's instructions

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-266-

24/02/2006 10:50:51 AM

Brought forward 3969

R

Not Priced

R

Not Priced

Copper pipes Pipes shall be hard drawn and half-hard "Maksal" pipes of the class described. Class 0 (thin walled hard drawn) pipes shall not be bent. Class 1 (thin walled half-hard), Class 2 (half-hard) and Class 3 (heavy walled half-hard) pipes shall only be bent with benders with inner and outer formers. Fittings to copper waste, vent and anti-syphon pipes, capillary solder fittings and compression fittings shall be "Cobra Watertech" type. Capillary solder fittings shall comply with ISO 2016

3971

Copper pipes are to be installed in accordance with the latest revision of the Code of Practice for Copper Plumbing soldering techniques. Flux, solder, etc to be strictly in accordance with the manufacturer's requirements with special attention to copper flux composition

3972

Reducing fittings Where fittings have reducing ends or branches they are described as "reducing" and only the largest end or branch size is given. Should the contractor wish to use other fittings and bushes or reducers he may do so on the understanding that no claim in this regard will be entertained

3974

Fixing of pipes

3975

Unless specifically otherwise stated, descriptions of pipes shall be deemed to include fixing to walls, etc, casting in, building in or suspending not exceeding 1m below suspension level

3976

Paper wrapping to pipes

3977

Pipes chased into brickwork must be wrapped with two layers of stout brown paper tied with wire. Rates are to include for wrapping around joints and fittings

3978

Disinfection of water pipework

3979

Water pipework is to be disinfected at completion in accordance with SABS 1200L (provision for disinfection elsewhere)

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-267-

24/02/2006 10:50:51 AM

Brought forward 3980

R

Not Priced

R

Not Priced

"Densyl" petrolatum anti-corrosion tape as manufactured by Denso SA (Pty) Ltd. Pipes to be taped shall be coated with the appropriate primer and the tape shall be applied in the appropriate widths and with ?% overlaps Couplings and fittings to pipes shall be taped in strict accordance with the manufacturer's instructions including mastic, tape, "Layflat" sheeting, securing of same, etc

3982

Prices for wrapping of pipes shall include for all work as described to couplings in the length

3983

Laying, backfilling, bedding, etc of pipes Pipes shall be laid and bedded in accordance with manufacturers' instructions and trenches shall be carefully backfilled

3985

Where no manufacturers' instructions exist, pipes shall be laid in accordance with Clauses 5.1 and 5.2 of each of the following: SABS 1200L : Medium-pressure pipelines SABS 1200LD: Sewers SABS 1200LE : Stormwater drainage Pipe trenches, etc shall be backfilled in accordance with Clauses 3, 5.5, 5.6, 5.7 and 7 of SABS 1200DB : Earthworks (Pipe trenches) Pipes shall be bedded in accordance with Clauses 3.1 to 3.4.1, 5.1 to 5.3 and 7 of SABS 1200LB : Bedding (Pipes) Unless otherwise described bedding of rigid pipes shall be Class B bedding

3986

General

3987

Descriptions of cast iron roof outlets shall be deemed to include joints to pipes and casting into concrete (adaptors for joints to PVC pipes, etc are given separately) Descriptions of overflow pipes where measured in number, shall be deemed to include joints to cisterns and splay cut ends

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-268-

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

3988

Descriptions of pipes laid in and including trenches and of inspection chambers, catchpits, etc shall be deemed to include excavation, bedding, backfilling, compaction to a minimum of ?% Mod AASHTO density and disposal of surplus material on site

3989

Descriptions of service pipes and flexible connecting pipes shall be deemed to include connections to taps, cisterns, etc and to steel pipes (adaptors for connections to copper pipes, etc are given separately)

3990

Descriptions of WC pans, slop hoppers, etc shall be deemed to include for joints to soil pipes (pan connectors are separately measured)

3991

As-built drawings

3992

Where required, the contractor shall prepare an updated set of as-built drawings. At completion of the contract the contractor shall hand these drawings to the principal agent for reproducing onto the originals for handing over to the employer (provision for allowance of as-built drawings elsewhere)

3993

RAINWATER DISPOSAL

3994

0,6mm Galvanised sheet steel gutters and rainwater pipes

3995

0,6mm Galvanised sheet steel gutters and rainwater pipes with powder coated finish on outside

3996

"?" seamless aluminium prepainted gutters and rainwater pipes

3997

Fibre-cement gutters and rainwater pipes

3998

"?" uPVC gutters and rainwater pipes

3999

?mm Half-round roof gutters

m

Not Priced

4000

?mm Half-round roof gutters with beaded front edge

m

Not Priced

4001

? x ?mm Roof gutters with beaded front edge

m

Not Priced

4002

? x ? x ?mm VHV roof gutters

m

Not Priced

4003

? x ?mm Ogee roof gutters

m

Not Priced

4004

?mm Diameter rainwater pipes

m

Not Priced

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-269-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4005

? x ?mm Rainwater pipes

4006

User note

4007

The applicable "extra over" items from the following list are to be inserted directly after each of the foregoing items

4008

R

Not Priced

m

Not Priced

Extra over gutter for stopped end

No

Not Priced

4009

Extra over gutter for angle

No

Not Priced

4010

Extra over gutter for outlet for ?mm pipe

No

Not Priced

4011

Extra over gutter for outlet for ? x ?mm pipe

No

Not Priced

4012

Extra over rainwater pipe for bend

No

Not Priced

4013

Extra over rainwater pipe for plinth bend

No

Not Priced

4014

Extra over rainwater pipe for shoe

No

Not Priced

4015

Extra over rainwater pipe for eaves or plinth offset

No

Not Priced

4016

Extra over rainwater pipe for swan-neck

No

Not Priced

4017

Spreader for ?mm pipe

No

Not Priced

4018

Spreader for ? x ?mm pipe

No

Not Priced

4019

Spreader ?mm long for ?mm diameter pipe with half closed ends and ?mm diameter holes at ?mm centres

No

Not Priced

Spreader ?mm long for ? x ?mm pipe with half closed ends and ?mm diameter holes at ?mm centres

No

Not Priced

? x ? x ?mm Deep rainwater head with outlet for ?mm diameter pipe

No

Not Priced

? x ? x ?mm Deep rainwater head with outlet for ? x ?mm pipe

No

Not Priced

4020

4021

4022

4023

uPVC SV pipes

4024

?mm Pipes

m

Not Priced

4025

?mm Pipes laid in and including trenches not exceeding 1m deep

m

Not Priced

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-270-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4026

Extra over uPVC SV pipes for fittings

4027

?mm BSP adaptor to cast iron

No

Not Priced

4028

?mm Bend

No

Not Priced

4029

?mm Long radius bend

No

Not Priced

4030

?mm Junction

No

Not Priced

4031

?mm Reducing junction

No

Not Priced

4032

?mm Cast iron bend including adaptors

No

Not Priced

4033

Cast iron pipes with SSN couplings

4034

Galvanised steel pipes with screwed and socketed joints

4035

Galvanised steel pipes with grooved ends and galvanised "?" grooved couplings

4036

?mm Pipes

m

Not Priced

4037

?mm Pipes suspended exceeding ?m and not exceeding ?m below concrete soffits

m

Not Priced

?mm Pipes suspended exceeding ?m and not exceeding ?m below steel roof trusses at ?mm centres

m

Not Priced

?mm Pipes on purpose made supports (supports elsewhere)

m

Not Priced

?mm Pipes laid in and including trenches not exceeding 1m deep

m

Not Priced

?mm Weep pipe ?mm long with splay-cut end, built through brickwork

No

Not Priced

4038

4039

4040

4041

4042

Extra over cast iron pipes with SSN couplings for fittings

4043

Extra over galvanised steel pipes with screwed and socketed joints for steel fittings

4044

Extra over galvanised steel pipes with "?" grooved couplings for galvanised "?" grooved fittings

4045

?mm Bend

No

Not Priced

4046

?mm Tee

No

Not Priced

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-271-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4047

?mm Junction

No

Not Priced

4048

?mm Reducing junction

No

Not Priced

4049

"?" cast iron outlets

4050

?mm Vertical outlet

No

Not Priced

4051

?mm 45° Side outlet

No

Not Priced

4052

?mm Two-way outlet

No

Not Priced

4053

SUBSOIL DRAINAGE

4054

Excavation in earth not exceeding 1m deep for pipe trenches



Not Priced

4055

Backfilling to pipe trenches



Not Priced

4056

?mm Crushed stone encasing to pipes



Not Priced

4057

"?" geofabric filter blanket wrapped around ? x ?mm stone encasing with ?mm side and ?mm end laps, including stitching



Not Priced

"?" geofabric filter blanket wrapped around ?mm diameter agricultural pipes with ?mm side and ?mm end laps, including stitching

m

Not Priced

m

Not Priced

4058

4059

HDPe pipes

4060

Slotted uPVC flexible drainage pipes

4061

?mm Pipes laid in stone encasing (encasing elsewhere)

4062

Extra over HDPe pipes for fittings

4063

Extra over slotted uPVC flexible drainage pipes for fittings

4064

?mm End cap

No

Not Priced

4065

?mm Bend

No

Not Priced

4066

?mm Junction

No

Not Priced

4067

STORMWATER CHANNELS

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-272-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4068

Precast concrete channels

4069

? x ?mm Channels with ? x ?mm deep segmental channel

4070

4071

R

Not Priced

m

Not Priced

Extra over for angles, intersections, ends, dressing into sides of catchpits, etc

No

Not Priced

? x ?mm Channel ?mm long with ? x ?mm deep segmental channel with one open end and one stopped end

No

Not Priced

4072

STORMWATER DRAINAGE

4073

Excavation in earth not exceeding 1m deep for pipe trenches



Not Priced

Excavation in earth exceeding ?m and not exceeding ?m deep for pipe trenches



Not Priced

4075

Backfilling to pipe trenches



Not Priced

4076

Backfilling to pipe trenches compacted to ?% Mod AASHTO density



Not Priced

Selected granular filling in bedding under and filling around pipes



Not Priced

4078

Sand filling in bedding under and filling around pipes



Not Priced

4079

?mm Crushed stone bedding under pipes



Not Priced

4080

Unreinforced concrete bedding under pipes



Not Priced

4081

Class 100D concrete pipes with interlocking joints

4082

Class 100D concrete pipes with spigot and socket joints with rubber rings

4083

?mm Pipes laid in trenches (trenches elsewhere)

m

Not Priced

4084

?mm Pipes laid in and including trenches not exceeding 1m deep

m

Not Priced

?mm Pipes laid in and including trenches exceeding ?m and not exceeding ?m deep

m

Not Priced

4074

4077

4085

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-273-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4086

User note

4087

The following inspection chambers, catchpits, etc which are given in number may also, according to the Standard System, be measured in detail. See soil drainage for an example

4088

Sumps, catchpits, inspection chambers, etc including concrete kerbs or precast concrete cover slabs (gratings and covers elsewhere)

4089

User note

4090

Attention is drawn to the fact that suitable grouping according to depth may be adopted in the event of numerous items occuring, as shown in the following items

4091

? x ?mm Junction box ?mm deep internally

No

Not Priced

4092

? x ?mm Junction box not exceeding ?mm deep internally

No

Not Priced

4093

? x ?mm Junction box exceeding ?mm and not exceeding ?mm deep internally

No

Not Priced

4094

? x ?mm Rainwater sump ?mm deep internally

No

Not Priced

4095

? x ?mm Rainwater sump not exceeding ?mm deep internally

No

Not Priced

? x ?mm Rainwater sump exceeding ?mm and not exceeding ?mm deep internally

No

Not Priced

4097

? x ?mm Brick catchpit ?mm deep internally

No

Not Priced

4098

? x ?mm Brick catchpit not exceeding ?mm deep internally

No

Not Priced

4099

? x ?mm Brick catchpit exceeding ?mm and not exceeding ?mm deep internally

No

Not Priced

4100

? x ?mm Brick inspection chamber ?mm deep internally

No

Not Priced

4101

? x ?mm Brick inspection chamber not exceeding ?mm deep internally

No

Not Priced

? x ?mm Brick inspection chamber exceeding ?mm and not exceeding ?mm deep internally

No

Not Priced

4096

4102

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-274-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4103

4104

4105

4106

4107

4108

R

Not Priced

? x ?mm Brick inspection chamber ?mm deep internally, the lower ?mm increased to ? x ?mm internally and with 150mm precast concrete reducer slab No

Not Priced

? x ?mm Brick inspection chamber exceeding ?mm and not exceeding ?mm deep internally, the lower ?mm increased to ? x ?mm internally and with 150mm precast concrete reducer slab

No

Not Priced

?mm Diameter precast concrete circular inspection chamber ?mm deep internally

No

Not Priced

?mm Diameter precast concrete circular inspection chamber not exceeding ?mm deep internally

No

Not Priced

?mm Diameter precast concrete circular inspection chamber exceeding ?mm and not exceeding ?mm deep internally

No

Not Priced

?mm Diameter precast concrete circular inspection chamber exceeding ?mm and not exceeding ?mm deep internally, the lower ?mm increased to ?mm diameter internally and with 150mm precast concrete reducer slab

No

Not Priced

4109

Cast iron gratings, covers, etc

4110

? x ?mm x ?kg Dished grating and frame

No

Not Priced

4111

? x ?mm x ?kg Stormwater grating and frame

No

Not Priced

4112

? x ?mm x ?kg Single seal manhole cover and frame

No

Not Priced

4113

? x ?mm x ?kg Double seal manhole cover and frame

No

Not Priced

4114

?mm Diameter x ?kg road manhole cover and frame

No

Not Priced

4115

Lifting-key for manhole cover (handed to employer)

No

Not Priced

4116

Municipal connection

4117

Provide the sum of R ? (? Rand) for municipal connection

Item

Not Priced

4118

Profit

Item

Not Priced

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-275-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4119

SLEEVES FOR ELECTRICAL AND TELEPHONE CABLES ETC

4120

Excavation in earth not exceeding 1m deep for pipe trenches



Not Priced

Excavation in earth exceeding ?m and not exceeding ?m deep for pipe trenches



Not Priced

4122

Backfilling to pipe trenches



Not Priced

4123

Backfilling to pipe trenches compacted to ?% Mod AASHTO density



Not Priced

Selected granular filling in bedding under and filling around pipes



Not Priced

4125

?mm Crushed stone bedding under pipes



Not Priced

4126

Unreinforced concrete bedding under pipes



Not Priced

4127

uPVC SV pipes

4128

Class 6 uPVC pipes

4129

?mm Pipes laid in trenches (trenches elsewhere)

m

Not Priced

4130

Set of two (three?, six?) ?mm pipes laid side-by-side in trenches (trenches elsewhere)

m

Not Priced

?mm Pipes laid in and including trenches not exceeding 1m deep

m

Not Priced

Set of two (three?, six?) ?mm pipes laid side-by-side in and including trenches not exceeding 1m deep

m

Not Priced

Set of six ?mm pipes in two tiers, one on top of the other, laid in and including trenches not exceeding 1m deep

m

Not Priced

4121

4124

4131

4132

4133

4134

Extra over uPVC SV pipes for fittings

4135

Extra over Class 6 uPVC pipes for fittings

4136

?mm Bend

No

Not Priced

4137

?mm Long radius bend

No

Not Priced

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-276-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4138

Draw wires

4139

1,6mm Galvanised steel draw wires in pipes

4140

Inspection chambers

4141

User note

4142

Attention is drawn to the fact that suitable grouping according to depth may be adopted in the event of numerous items occuring, as shown in the following items

4143

? x ?mm Brick inspection chamber ?mm deep internally, including precast concrete cover slab (cover elsewhere)

4144

4145

4146

R

Not Priced

m

Not Priced

m

Not Priced

? x ?mm Brick inspection chamber not exceeding ?mm deep internally, including precast concrete cover slab (cover elsewhere)

No

Not Priced

? x ?mm Brick inspection chamber exceeding ?mm and not exceeding ?mm deep internally, including precast concrete cover slab (cover elsewhere)

No

Not Priced

? x ?mm x ?kg Cast iron single seal manhole cover and frame

No

Not Priced

4147

SOIL DRAINAGE

4148

Excavation in earth not exceeding 1m deep for pipe trenches



Not Priced

Excavation in earth exceeding ?m and not exceeding ?m deep for pipe trenches



Not Priced

4150

Backfilling to pipe trenches



Not Priced

4151

Backfilling to pipe trenches compacted to ?% Mod AASHTO density



Not Priced

Selected granular filling in bedding under and filling around pipes



Not Priced

4153

?mm Crushed stone bedding under pipes



Not Priced

4154

Unreinforced concrete bedding under pipes



Not Priced

4149

4152

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-277-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4155

User note

4156

When inspection chambers are measured in detail, the channels are to be given separately as set out in the following four items

4157

Normal duty uPVC sewer channels

4158

?mm Channels in bottoms of inspection chambers

4159

Extra over normal duty uPVC sewer channels for fittings

4160

R

Not Priced

m

Not Priced

?mm Bend

No

Not Priced

4161

?mm Junction

No

Not Priced

4162

?mm Double junction

No

Not Priced

4163

Normal duty (Class 51) uPVC sewer and drain pipes

4164

Heavy duty (Class 34) uPVC sewer and drain pipes

4165

?mm Pipes vertically or ramped to cleaning eyes etc (no excavation)

m

Not Priced

4166

?mm Pipes laid in trenches (trenches elsewhere)

m

Not Priced

4167

?mm Pipes laid in and including trenches not exceeding 1m deep

m

Not Priced

?mm Pipes laid in and including trenches exceeding ?m and not exceeding ?m deep

m

Not Priced

4168

4169

Extra over normal duty (Class 51) uPVC sewer and drain pipes for fittings

4170

Extra over heavy duty (Class 34) uPVC sewer and drain pipes for fittings

4171

?mm Bend

No

Not Priced

4172

?mm Junction

No

Not Priced

4173

?mm Reducing junction

No

Not Priced

4174

?mm Access pipe

No

Not Priced

4175

?mm Access bend

No

Not Priced

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-278-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4176

?mm Access junction

No

Not Priced

4177

?mm Access reducing junction

No

Not Priced

4178

?mm Access double junction

No

Not Priced

4179

?mm Rodding eye

No

Not Priced

4180

?mm Overflow gulley head

No

Not Priced

4181

Vitrified clay pipes

4182

Cast iron pipes with SSN couplings

4183

?mm Pipes vertically or ramped to cleaning eyes etc (no excavation)

m

Not Priced

4184

?mm Pipes laid in trenches (trenches elsewhere)

m

Not Priced

4185

?mm Pipes laid in and including trenches not exceeding 1m deep

m

Not Priced

?mm Pipes laid in and including trenches exceeding ?m and not exceeding ?m deep

m

Not Priced

4186

4187

Extra over vitrified clay pipes for fittings

4188

Extra over cast iron pipes with SSN couplings for fittings

4189

?mm Taper pipe

No

Not Priced

4190

?mm Bend

No

Not Priced

4191

?mm Junction

No

Not Priced

4192

?mm Reducing junction

No

Not Priced

4193

?mm Access bend

No

Not Priced

4194

?mm Access junction

No

Not Priced

4195

?mm Access reducing junction

No

Not Priced

4196

Vitrified clay gulleys

4197

Cast iron gulleys

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-279-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4198

uPVC gulleys

4199

?mm Gulley not exceeding 500mm deep

No

Not Priced

4200

?mm Gulley exceeding 500mm and not exceeding 750mm deep

No

Not Priced

4201

?mm Gulley exceeding ?mm and not exceeding ?mm deep

No

Not Priced

4202

?mm Dished gulley not exceeding 500mm deep

No

Not Priced

4203

?mm Dished gulley exceeding 500mm and not exceeding 750mm deep

No

Not Priced

?mm Dished gulley exceeding ?mm and not exceeding ?mm deep

No

Not Priced

4204

4205

Brick inspection chambers including precast concrete cover slabs (covers elsewhere) and channels in benching

4206

User note

4207

Attention is drawn to the fact that suitable grouping according to depth may be adopted in the event of numerous items occuring, as shown in the following items

4208

? x ?mm Inspection chamber ?mm deep internally

No

Not Priced

4209

? x ?mm Inspection chamber not exceeding ?mm deep internally

No

Not Priced

? x ?mm Inspection chamber exceeding ?mm and not exceeding ?mm deep internally

No

Not Priced

? x ?mm Inspection chamber ?mm deep internally, the lower ?mm increased to ? x ?mm internally and with 150mm precast concrete reducer slab

No

Not Priced

? x ?mm Inspection chamber exceeding ?mm and not exceeding ?mm deep internally, the lower ?mm increased to ? x ?mm internally and with 150mm precast concrete reducer slab

No

Not Priced

No

Not Priced

4210

4211

4212

4213

Precast concrete circular inspection chambers including precast concrete cover slabs (covers elsewhere) and channels in benching

4214

?mm Diameter inspection chamber ?mm deep internally

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-280-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4215

4216

4217

4218

4219

R

Not Priced

?mm Diameter inspection chamber not exceeding ?mm deep internally

No

Not Priced

?mm Diameter inspection chamber exceeding ?mm and not exceeding ?mm deep internally

No

Not Priced

?mm Diameter inspection chamber ?mm deep internally, the lower ?mm depth increased to ?mm diameter and with 150mm precast concrete reducer slab

No

Not Priced

?mm Diameter inspection chamber not exceeding ?mm deep internally, the lower ?mm depth increased to ?mm diameter and with 150mm precast concrete reducer slab

No

Not Priced

?mm Diameter inspection chamber exceeding ?mm and not exceeding ?mm deep internally, the lower ?mm depth increased to ?mm diameter and with 150mm precast concrete reducer slab

No

Not Priced

4220

Cast iron covers etc

4221

? x ?mm x ?kg Double seal manhole cover and frame

No

Not Priced

4222

?mm Diameter x ?kg pavement manhole cover and frame

No

Not Priced

4223

User note

4224

Step irons are only measurable where inspection chambers are measured out in detail, i.e. not separately measurable when in number

4225

The following in ? inspection chambers

4226

Excavation in earth not exceeding 2m deep



Not Priced

4227

Excavation in earth exceeding ?m and not exceeding ?m deep



Not Priced

4228

Unreinforced concrete in bottoms



Not Priced

4229

Reinforced concrete in bottoms



Not Priced

4230

Unreinforced concrete benching in bottom of ? x ?mm chamber, dished down to channels and finished smooth with cement plaster

No

Not Priced

? x ? x ?mm Thick precast concrete reducer slab with ? x ?mm opening including necessary formwork and reinforcement

No

Not Priced

4231

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-281-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4232

4233

4234

? x ? x ?mm Thick precast concrete cover slab with ? x ?mm rebated opening for cover and frame and finished smooth on exposed surfaces with cement plaster, including formwork and reinforcement

R

Not Priced

No

Not Priced

?mm Diameter mild steel reinforcing bars in concrete bottoms

t

Not Priced

?mm Diameter high tensile steel reinforcing bars in concrete bottoms

t

Not Priced

4235

Type ? fabric reinforcement in concrete bottoms



Not Priced

4236

One brick walls



Not Priced

4237

One and a half brick walls



Not Priced

4238

Extra over for fair face to brickwork pointed with flush joints



Not Priced

4239

Plaster on brick walls



Not Priced

4240

? x ?mm x ?kg Cast iron double seal manhole cover and frame

No

Not Priced

?mm Diameter x ?kg cast iron pavement manhole cover and frame

No

Not Priced

?mm Diameter galvanised steel rod step iron ?mm long, built in across corner of chamber

No

Not Priced

? x ?mm Cast iron horseshoe pattern step iron built into brickwork

No

Not Priced

4244

Lifting-key for manhole cover (handed to employer)

No

Not Priced

4245

French drains

4246

French drain ? x ?mm deep x ?mm long

No

Not Priced

4247

Septic tanks

4248

"?" standard ? litre PVC septic tank

No

Not Priced

4249

"?" fibre-cement septic tank ?mm diameter and ?mm deep, complete with all accessories, components, etc

No

Not Priced

4241

4242

4243

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-282-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4250

SUNDRIES

4251

Extra over excavation in earth for pipe trenches, chambers, etc for excavation in soft rock



Not Priced

Extra over excavation in earth for pipe trenches, chambers, etc for excavation in hard rock



Not Priced

Extra over excavation for pipe trenches, chambers, etc for carting away surplus material to a dumping site to be located by the contractor



Not Priced

Extra over backfilling to drain trenches, chambers, etc for suitable earth backfilling supplied by the contractor



Not Priced

4252

4253

4254

4255

User note

4256

The previous item is only measurable if the material on site is not suitable for backfilling

4257

Excavate not exceeding 1m deep for, locate, take up and remove ?mm soil drain pipe, including backfilling, compaction, etc

m

Not Priced

?mm Wide protection slab over horizontal pipes, of ? x ? x ?mm precast concrete slabs

m

Not Priced

4259

Concrete encasing to ?mm horizontal pipes

m

Not Priced

4260

Concrete encasing to ?mm vertical pipes

m

Not Priced

4261

Concrete encasing to ?mm vertical bend

No

Not Priced

4262

350 x 350 x 50mm Precast concrete inspection eye marker slab set in ground

No

Not Priced

? x ?mm x ?kg Cast iron cover and frame over cleaning eye (cleaning eye elsewhere), including concrete encasing

No

Not Priced

Cutting into existing ?mm drain pipe for and forming junction with ?mm pipe

No

Not Priced

Cutting into side of existing inspection chamber for and connecting ?mm pipe, including inserting ?mm channel junction and making good concrete benching

No

Not Priced

4258

4263

4264

4265

4266

Municipal connection

4267

Provide the sum of R ? (? Rand) for municipal connection

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-283-

Item

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4268

Profit

4269

Testing

4270

Testing soil drainage system

4271

SANITARY FITTINGS

4272

"?" stainless steel

4273

? x ?mm Type ? wash hand basin on galvanised steel gallows brackets

No

Not Priced

? x ?mm Type ? range of three wash hand basins on galvanised steel gallows brackets and legs with adjustable feet

No

Not Priced

? x ?mm Type ? sink with ? x ?mm end bowl on galvanised steel brackets

No

Not Priced

? x ?mm Type ? sink with ? x ?mm end bowl on cupboard (cupboard elsewhere)

No

Not Priced

? x ?mm Type ? sink wiith two ? x ?mm end bowls on cupboard (cupboard elsewhere)

No

Not Priced

? x ?mm Type ? sink with two ? x ?mm centre bowls on cupboard (cupboard elsewhere)

No

Not Priced

4279

?mm Diameter type ? drop-in preparation bowl

No

Not Priced

4280

? x ?mm Type ? single bowl wash trough on galvanised steel brackets

No

Not Priced

? x ?mm Type ? curved back urinal with ? litre automatic high level cistern, flush and sparge pipes and hinged domical grating

No

Not Priced

? x ?mm Type ? curved back urinal with inlet for flush valve (flush valve elsewhere) sparge pipes and hinged domical grating

No

Not Priced

? x ?mm Type ? L-shaped curved back urinal with two ? litre automatic high level cisterns, flush and sparge pipes and hinged domical grating

No

Not Priced

? x ?mm Type ? curved back urinal with standard integral automatic flush tray, drip cock and hinged domical grating

No

Not Priced

4274

4275

4276

4277

4278

4281

4282

4283

4284

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-284-

Item

Not Priced

Item

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4285

User note

4286

Selected examples of typical items with trade names are provided to show possible ways of describing such items. Users must adapt these examples to suit their particular circumstances

4287

"Vaal"

4288

Taphole stopper

No

Not Priced

4289

560 x 405mm "Springbok" 0112 lavatory basin on brackets

No

Not Priced

4290

510 x 405mm "Daisy" 7061 lavatory basin on 57150 floor mounted pedestal

No

Not Priced

4291

455 x 290mm "Bantam" 7030 cloakroom basin bolted to wall

No

Not Priced

4292

595 x 455mm "Cameo" 0006 vanity basin mounted in vanity slab or cupboard top (vanity slab or cupboard elsewhere)

No

Not Priced

"Klip" 400010 WC pan with double flap heavy duty plastic seat (flush valve elsewhere)

No

Not Priced

"Klip" 400010 low level WC suite comprising WC pan with double flap heavy duty plastic seat and matching 9 litre cistern with flush pipe

No

Not Priced

"Hibiscus" 772602 close-coupled WC suite comprising pan with double flap heavy duty plastic seat and matching 9 litre cistern

No

Not Priced

"Lotus" 438501 wall hung WC pan with cradle bracket and legs and "Kestrel" double flap white epoxy painted wooden seat (flush valve elsewhere)

No

Not Priced

"Orchid" 439004 wall hung paraplegic WC pan with cradle bracket and legs and "Kestrel" double flap white epoxy painted wooden seat (flush valve elsewhere)

No

Not Priced

4298

"Concorde" 7737 bidet

No

Not Priced

4299

"Lavatera" 704001/2 wall urinal with spreader and waste union (flush valve elsewhere)

No

Not Priced

"Flatback" 7053 wall urinal with 4,5 litre high level automatic flushing cistern with exposed flush pipe, spreader and waste union

No

Not Priced

4293

4294

4295

4296

4297

4300

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-285-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4301

"Plexicor" acrylic

4302

900 x 900 x 150mm "Granada" shower tray with waste outlet, bedded in position

No

Not Priced

1700 x 750mm "Carmen" bath with waste outlet, overflow grating with coupling and pair of handles, bedded in position

No

Not Priced

4303

4304

"?" enamelled steel baths

4305

? x ?mm "?" bath with waste outlet, overflow grating with coupling and pair of handles, bedded in position

No

Not Priced

? x ?mm "?" bath with waste outlet, overflow grating with coupling, pair of handles and adjustable legs

No

Not Priced

4306

4307

WASTE UNIONS ETC

4308

"Cobra Watertech"

4309

32mm 301 CP basin waste union

No

Not Priced

4310

32mm 303 CP basin waste union and 309CP anti-theft plug

No

Not Priced

4311

40mm 316 CP bath or sink waste union

No

Not Priced

4312

32mm 320 CP bath overflow union

No

Not Priced

4313

TRAPS ETC

4314

uPVC

4315

?mm One-way vent valve

No

Not Priced

4316

Rubber

4317

?mm "P" or "S" trap

No

Not Priced

4318

?mm Reseal "P" or "S" trap

No

Not Priced

4319

?mm Bath "P" trap with overflow outlet and pipe

No

Not Priced

4320

? x ?mm Double bowl wash trough or sink reseal "P" or "S" trap combination

No

Not Priced

No

Not Priced

4321

"Elf"

4322

?mm Anti-vac bottle trap

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-286-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4323

Cast iron

4324

?mm "P" trap

No

Not Priced

4325

?mm "P" urinal trap

No

Not Priced

4326

"Cobra Watertech"

4327

75mm VA3.113 CP hinged urinal domical grating

No

Not Priced

4328

40mm 373 RB shower trap with chromium plated grating

No

Not Priced

4329

50mm VA2.342 RB shower trap with VA3.334-4 CP waste and grating

No

Not Priced

4330

32mm 340 CP bottle trap

No

Not Priced

4331

40mm 360 CP bottle trap

No

Not Priced

4332

32mm 340 CP bottle trap with C-342/1/2/9 tail pipe

No

Not Priced

4333

40mm 370 Bath trap with 330 combined bath waste and overflow

No

Not Priced

No

Not Priced

4334

"Eurodrain"

4335

100mm "Kessel" floor drain

4336

"Rofo"

4337

RO 125 V (H) NW 50 stainless steel floor trap with grating

No

Not Priced

4338

RO 200 V (H) NW 100 stainless steel floor trap with grating

No

Not Priced

4339

TAPS, VALVES, ETC

4340

Brass

4341

?mm Stopcock

No

Not Priced

4342

?mm Fullway gate valve

No

Not Priced

4343

?mm Hose bib-tap

No

Not Priced

4344

?mm Non-return valve

No

Not Priced

4345

"Cobra Watertech"

4346

15mm 059-15CP extension piece with sliding wall flange

No

Not Priced

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-287-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4347

20mm 059-20CP extension piece with sliding wall flange

No

Not Priced

4348

15mm 232/350CP angle regulating valve and connection pipe

No

Not Priced

15mm 232/350 FCP angle regulating valve and flexible connection pipe

No

Not Priced

4350

15mm 1065-15CP fullway isolating ball valve

No

Not Priced

4351

15mm 1075-15CP fullway isolating ball valve

No

Not Priced

4352

20mm 1080-20RB fullway isolating ball valve with lever handle

No

Not Priced

25mm 1080-25RB fullway isolating ball valve with lever handle

No

Not Priced

4354

15mm 1090CP fullway ballcock

No

Not Priced

4355

15mm 121-15RB stopcock

No

Not Priced

4356

20mm 121-20RB stopcock

No

Not Priced

4357

15mm 133-15RB stopcock

No

Not Priced

4358

22mm 133-22RB stopcock

No

Not Priced

4359

15mm 131-15RB stopcock

No

Not Priced

4360

22mm 131-22RB stopcock

No

Not Priced

4361

15mm 126-15CP stopcock

No

Not Priced

4362

15mm 136-15CP "Star" stopcock

No

Not Priced

4363

15mm 128-15CP "Star" undertile stopcock

No

Not Priced

4364

15mm 138CA-15CP "Carina" undertile stopcock

No

Not Priced

4365

20mm 128CA-20CP "Carina" undertile stopcock

No

Not Priced

4366

15mm 1001/125-15RB fullway gate valve

No

Not Priced

4367

20mm 1001/125-20RB fullway gate valve

No

Not Priced

4368

15mm 1003/125-15RB fullway gate valve

No

Not Priced

4369

22mm 1003/125-22RB fullway gate valve

No

Not Priced

4349

4353

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-288-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4370

25mm 700-25RB high pressure float valve including ball

No

Not Priced

4371

32mm 700-32RB high pressure float valve including ball

No

Not Priced

4372

15mm 100-15RB bib-tap

No

Not Priced

4373

20mm 100-20RB bib-tap

No

Not Priced

4374

15mm 106-15CP "Star" bib-tap

No

Not Priced

4375

20mm 106AQ-20CP "Aquila" bib-tap

No

Not Priced

4376

15mm 107EC-15CP hose bib-tap

No

Not Priced

4377

15mm 111-15CP pillar tap

No

Not Priced

4378

20mm 111-20CP pillar tap

No

Not Priced

4379

15mm 114AQ-15CP "Aquila" pillar tap

No

Not Priced

4380

20mm 114CA-20CP "Carina" pillar tap

No

Not Priced

4381

15mm 505-21CP elbow action pillar tap

No

Not Priced

4382

15mm 903CP "Focus" basin mixer with angle flow regulating valves

No

Not Priced

15mm 902CP "Focus" basin mixer with waste union, etc and angle flow regulating valves

No

Not Priced

15mm 900CP "Focus" basin mixer with pop-up waste and angle flow regulating valves

No

Not Priced

4385

15mm 166/041CP "Star" sink mixer

No

Not Priced

4386

20mm 147AQCP "Aquila" bath mixer

No

Not Priced

4387

20mm 149CP "Carina" bath mixer with "Cascade" hand shower and attachments

No

Not Priced

15mm 181/020/070CP shower mixer with riser pipe, arm and shower head

No

Not Priced

4389

20mm 860CP bath spout

No

Not Priced

4390

15mm 078CP shower head

No

Not Priced

4391

15mm 072CP shower head

No

Not Priced

4383

4384

4388

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-289-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4392

15mm 027CP overhead shower arm

No

Not Priced

4393

15mm 026CP overhead shower arm and 063CP ball joint

No

Not Priced

4394

15mm 1022RB check valve

No

Not Priced

4395

15mm 1025RB automatic closing check valve

No

Not Priced

4396

15mm 1050RB in-line strainer

No

Not Priced

4397

PB1.10RB vacuum breaker

No

Not Priced

4398

PA3.132 "Masterflo 1" pressure control valve with vacuum breaker

No

Not Priced

PA3.522 "Masterflo 1" pressure control valve with vacuum breaker

No

Not Priced

4400

FJ2.100CP "Flushmaster Junior" toilet flush valve

No

Not Priced

4401

FJ2.601CP "Flushmaster Junior" toilet flush valve

No

Not Priced

4402

FJ2.210CP "Flushmaster Junior" toilet flush valve

No

Not Priced

4403

FJ6.000CP "Flushmaster Junior" urinal flush valve

No

Not Priced

4404

FJ8.102CP "Flushmaster Junior" urinal flush valve

No

Not Priced

4405

FM1.100CP "Flushmaster" toilet flush valve

No

Not Priced

4406

FM2.100CP "Flushmaster" toilet flush valve

No

Not Priced

4407

FM1.210CP "Flushmaster" toilet flush valve

No

Not Priced

4408

FM1.210CP "Flushmaster" toilet flush valve with FM8.80 extended lever

No

Not Priced

4399

4409

SANITARY PLUMBING

4410

uPVC soil and vent pipes

4411

?mm Pipes

m

Not Priced

4412

?mm Pipes chased into brickwork

m

Not Priced

4413

?mm Pipes suspended exceeding ?m and not exceeding ?m below concrete soffits

m

Not Priced

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-290-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4414

?mm Pipes suspended exceeding ?m and not exceeding ?m below steel roof trusses at ?mm centres

R

Not Priced

m

Not Priced

4415

Extra over uPVC soil and vent pipes for fittings

4416

?mm End cap

No

Not Priced

4417

?mm BSP adaptor

No

Not Priced

4418

?mm Reducer

No

Not Priced

4419

?mm Eccentric reducer

No

Not Priced

4420

?mm Pan connector

No

Not Priced

4421

?mm Bend

No

Not Priced

4422

?mm Junction

No

Not Priced

4423

?mm Reducing junction

No

Not Priced

4424

?mm Inverted reducing junction

No

Not Priced

4425

?mm Double junction

No

Not Priced

4426

?mm Reducing double junction

No

Not Priced

4427

?mm Access pipe

No

Not Priced

4428

?mm Access bend

No

Not Priced

4429

?mm Access bend with anti-syphon horn

No

Not Priced

4430

?mm Access junction

No

Not Priced

4431

?mm Access reducing junction

No

Not Priced

4432

?mm Access double junction

No

Not Priced

4433

?mm Access reducing double junction

No

Not Priced

4434

?mm Stubstack

No

Not Priced

4435

?mm Air vent cowl

No

Not Priced

4436

Extra over uPVC soil and vent pipes for cast iron fittings

4437

?mm Bend

No

Not Priced

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-291-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4438

Cast iron pipes with SSN couplings

4439

Cast iron pipes with spigot and socket joints

4440

?mm Pipes

m

Not Priced

4441

?mm Pipes laid in and including trenches not exceeding 1m deep

m

Not Priced

?mm Pipes suspended exceeding ?m and not exceeding ?m below concrete soffits

m

Not Priced

?mm Pipes suspended exceeding ?m and not exceeding ?m below steel roof trusses at ?mm centres

m

Not Priced

4442

4443

4444

Extra over cast iron pipes with SSN couplings for fittings

4445

Extra over cast iron pipes with spigot and socket joints for fittings

4446

?mm Eccentric reducer

No

Not Priced

4447

?mm Rodding eye

No

Not Priced

4448

?mm Bend

No

Not Priced

4449

?mm Junction

No

Not Priced

4450

?mm Reducing junction

No

Not Priced

4451

?mm Double junction

No

Not Priced

4452

?mm Reducing double junction



Not Priced

4453

?mm Pan connector

No

Not Priced

4454

?mm Access pipe

No

Not Priced

4455

?mm Access bend

No

Not Priced

4456

?mm Access bend with anti-syphon horn

No

Not Priced

4457

?mm Access junction

No

Not Priced

4458

?mm Access reducing junction

No

Not Priced

4459

?mm Access double junction

No

Not Priced

4460

?mm Access reducing double junction

No

Not Priced

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-292-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4461

?mm Stubstack

4462

Galvanised steel pipes with screwed and socketed joints

4463

R

Not Priced

No

Not Priced

?mm Pipes

m

Not Priced

4464

?mm Pipes chased into brickwork

m

Not Priced

4465

?mm Pipes suspended exceeding ?m and not exceeding ?m below concrete soffits

m

Not Priced

?mm Pipes suspended exceeding ?m and not exceeding ?m below steel roof trusses at ?mm centres

m

Not Priced

No

Not Priced

4466

4467

Extra over galvanised steel pipes with screwed and socketed joints for steel fittings

4468

?mm Bush

4469

Extra over galvanised steel pipes with screwed and socketed joints for brass fittings

4470

?mm Bend

No

Not Priced

4471

?mm Junction

No

Not Priced

4472

?mm Reducing junction

No

Not Priced

4473

?mm Access bend

No

Not Priced

4474

?mm Access junction

No

Not Priced

4475

?mm Access reducing junction

No

Not Priced

4476

"?" pumps etc

4477

Submersible sewage pumping plant comprising two pumps each to deliver ? litres/second at ?m head. The pumps to be complete with associated pipework including duckfoot bends, two ?mm non-return valves each with isolation valve and manifold to connect to ?mm rising main. The controls shall be in a wall-mounted, indoor, steel panel and shall include level control switches and alarms for extra high level and motor trip

No

Not Priced

No

Not Priced

4478

Sundries

4479

Wire balloon grating in top of pipe not exceeding 100mm diameter

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-293-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4480

Testing

4481

Testing waste pipe system

4482

WATER SUPPLIES

4483

Excavation in earth not exceeding 1m deep for pipe trenches



Not Priced

Excavation in earth exceeding ?m and not exceeding ?m deep for pipe trenches



Not Priced

4485

Backfilling to pipe trenches



Not Priced

4486

Backfilling to pipe trenches compacted to ?% Mod AASHTO density



Not Priced

Selected granular filling in bedding under and filling around pipes



Not Priced

4488

?mm Crushed stone bedding under pipes



Not Priced

4489

Unreinforced concrete bedding under pipes



Not Priced

4490

Class 16 uPVC pressure pipes with solvent welded joints

4491

?mm Pipes laid in and including trenches not exceeding 1m deep

m

Not Priced

No

Not Priced

4484

4487

Item

Not Priced

4492

Extra over Class 16 uPVC pressure pipes for fittings with solvent welded joints

4493

?mm Bend

4494

Extra over Class 16 uPVC pressure pipes for cast iron pressure fittings

4495

?mm Reducer

No

Not Priced

4496

?mm Tee

No

Not Priced

4497

?mm Reducing tee

No

Not Priced

4498

User note

4499

Class 16 uPVC pressure pipes and fittings larger than 50mm are available only with rubber-ring joints. Refer to "Water Supplies to Fire Appliances"

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-294-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4500

Class 10 HDPe type IV pipes

4501

?mm Pipes laid in and including trenches not exceeding 1m deep

R

Not Priced

m

Not Priced

4502

Extra over Class 10 HDPe type IV pipes for "Plasson" fittings

4503

?mm Fittings

No

Not Priced

4504

?mm Reducer

No

Not Priced

4505

?mm Bend

No

Not Priced

4506

?mm Threaded adaptor

No

Not Priced

4507

"Polycop" polypropylene pipes with "Fast-fuse" thermoplastic couplings

4508

User note

4509

"Polycop" pipes are only for pipes 54mm diameter and under

4510

?mm Pipes

m

Not Priced

4511

?mm Pipes chased into brickwork including brown paper lagging

m

Not Priced

?mm Pipes laid in and including trenches not exceeding 1m deep

m

Not Priced

4512

4513

Extra over "Polycop" polypropylene pipes for "Fast-fuse" thermoplastic fittings

4514

?mm Fittings

No

Not Priced

4515

?mm Reducing coupling

No

Not Priced

4516

?mm Elbow

No

Not Priced

4517

?mm Tee

No

Not Priced

4518

?mm Reducing elbow

No

Not Priced

4519

?mm Reducing tee

No

Not Priced

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-295-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4520

Extra over "Polycop" polypropylene pipes for brass compression fittings

4521

?mm Fittings

No

Not Priced

4522

?mm Adaptor coupling

No

Not Priced

4523

?mm Bent adaptor coupling

No

Not Priced

4524

?mm Reducing adaptor coupling

No

Not Priced

4525

?mm Reducing bent adaptor coupling

No

Not Priced

4526

?mm Elbow

No

Not Priced

4527

?mm Tee

No

Not Priced

4528

Galvanised steel pipes with screwed and socketed joints

4529

Galvanised pipes with grooved ends and galvanised "?" grooved couplings

4530

?mm Pipes

m

Not Priced

4531

?mm Pipes chased into brickwork including brown paper lagging

m

Not Priced

?mm Pipes laid in and including trenches not exceeding 1m deep

m

Not Priced

4532

4533

Extra over galvanised steel pipes with screwed and socketed joints for steel fittings

4534

Extra over galvanised steel pipes with "?" grooved couplings for galvanised "?" grooved fittings

4535

?mm Fittings

No

Not Priced

4536

?mm Plug

No

Not Priced

4537

?mm Bush

No

Not Priced

4538

?mm Elbow

No

Not Priced

4539

?mm Bend

No

Not Priced

4540

?mm Tee

No

Not Priced

4541

?mm Reducing tee

No

Not Priced

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-296-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4542

?mm Longscrew connector

No

Not Priced

4543

?mm "Johnson" coupling

No

Not Priced

4544

Class 0 (1?) copper pipes with capillary couplings

4545

Class 0 (1?) copper pipes with brass compression couplings

4546

User note

4547

Class 1 copper pipes are recommended for high quality installations

4548

?mm Pipes

m

Not Priced

4549

?mm Pipes chased into brickwork including brown paper lagging

m

Not Priced

4550

Extra over Class 0 (1?) copper pipes for capillary fittings

4551

?mm Fittings

No

Not Priced

4552

?mm Reducer

No

Not Priced

4553

?mm Elbow

No

Not Priced

4554

?mm Tee

No

Not Priced

4555

?mm Reducing tee

No

Not Priced

4556

?mm Threaded adaptor

No

Not Priced

4557

?mm Threaded bent adaptor

No

Not Priced

4558

?mm Threaded elbow

No

Not Priced

4559

?mm Threaded union

No

Not Priced

4560

Extra over Class 0 (1?) copper pipes for galvanised steel fittings

4561

?mm Flanged adaptor

No

Not Priced

4562

Extra over Class 0 (1?) copper pipes for brass compression fittings

4563

?mm Fittings

No

Not Priced

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-297-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4564

?mm Reducing coupling

No

Not Priced

4565

?mm Adaptor coupling

No

Not Priced

4566

?mm Bent adaptor coupling

No

Not Priced

4567

?mm Reducing adaptor coupling

No

Not Priced

4568

?mm Reducing bent adaptor coupling

No

Not Priced

4569

?mm Elbow

No

Not Priced

4570

?mm Tee

No

Not Priced

4571

?mm Reducing elbow

No

Not Priced

4572

?mm Reducing tee

No

Not Priced

4573

?mm Multi-step reducer

No

Not Priced

4574

Copper service pipes

4575

Flexible service pipes

4576

Chromium plated service pipes

4577

?mm Service pipe 350mm girth

No

Not Priced

4578

Sundries

4579

Unreinforced concrete in thrust blocks in trenches at bends, tees, etc including extra excavation, formwork, etc



Not Priced

? x ? x ?mm x ?kg Cast iron stopcock box including brick chamber below ?mm deep internally

No

Not Priced

? x ? x ?mm x ?kg Cast iron meter or valve box including brick chamber below ?mm deep internally

No

Not Priced

? x ?mm Brick valve chamber ?mm deep internally including concrete kerb (cover and frame elsewhere)

No

Not Priced

4583

? x ?mm x ?kg Cast iron single seal cover and frame

No

Not Priced

4584

Disinfecting

4585

Disinfecting water pipe and tank system

4580

4581

4582

Item

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-298-

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4586

Municipal connection

4587

Provide the sum of R ? (? Rand) for municipal connection

Item

Not Priced

4588

Profit

Item

Not Priced

4589

Testing

4590

Testing water pipe system

Item

Not Priced

4591

ELECTRIC WATER HEATERS

4592

"Kwikot"

4593

10 Litre "Prisma" over-basin electric water heater

No

Not Priced

4594

Type 195 mixer tap

No

Not Priced

4595

150 Litre "Econoflo" floor/wall electric water heater

No

Not Priced

4596

? Litre "Megaflo" floor/wall electric water heater

No

Not Priced

4597

"Stiebel Eltron"

4598

SHU 5S electric water heater

No

Not Priced

4599

SHU 10S electric water heater

No

Not Priced

4600

15mm SV valve

No

Not Priced

4601

DRIP TRAYS, TANKS, ETC

4602

0,6mm Galvanised sheet steel

4603

? x ?mm Drip tray for water heater, with 100mm high upstand all round with top edge bent over and with ?mm threaded outlet union

No

Not Priced

4604

"?" SG1 polyethylene drinking water tanks with black lining internally

4605

? Litre circular tank ?m diameter x ?m high, approximately ?m above ground level

No

Not Priced

Outlet union for ?mm steel (copper?) pipe including hole through tank

No

Not Priced

4606

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-299-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4607

"?" hot-dip galvanised steel sectional water tanks etc

4608

? x ? x ?mm Tank with external flanges, flat top and bolted manhole lid, approximately ?m above ground level

No

Not Priced

? x ? x ?mm Tank with external flanges, flat top, raised valve box and bolted manhole lid, approximately ?m above ground level

No

Not Priced

Outlet union for ?mm steel (copper? uPVC?) pipe, including hole through tank

No

Not Priced

4609

4610

4611

FIRE APPLIANCES ETC

4612

"?" hose reel with 30m plastic (rubber?) hose, chromium plated stopcock, shut-off nozzle and wall bracket

No

Not Priced

4613

?kg "?" dry chemical powder fire extinguisher

No

Not Priced

4614

?kg "?" carbon dioxide fire extinguisher

No

Not Priced

4615

100mm "?" diameter 2500 KPa pressure gauge syphon and stopcock, including tapped hole in steel pipe

No

Not Priced

80 x 65mm "?" brass right-angle hydrant valve with cap and chain

No

Not Priced

80 x 65mm "?" brass double booster pump connection and Y-piece, with caps and chains

No

Not Priced

100mm "?" brass hydrant including two flanged spacer pipes, 100mm duckfoot bend, connecting bolts, gaskets, etc

No

Not Priced

4619

100mm "?" cast iron flanged non-return valve

No

Not Priced

4620

100mm "?" cast iron flanged gate valve

No

Not Priced

4621

Fire hydrant pedestals

4622

Unreinforced concrete hydrant pedestal 900mm high, cast around vertical pipe with bottom 300mm below ground, 300 x 300mm square at base and tapering to 200 x 200mm overall octagonal shaped top, including excavation, formwork and two coats of paint to exposed surfaces

No

Not Priced



Not Priced

4616

4617

4618

4623

WATER SUPPLIES TO FIRE APPLIANCES

4624

Excavation in earth not exceeding 1m deep for pipe trenches

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-300-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4625

R

Not Priced

Excavation in earth exceeding ?m and not exceeding ?m deep for pipe trenches



Not Priced

4626

Backfilling to pipe trenches



Not Priced

4627

Backfilling to pipe trenches compacted to 95% Mod AASHTO density



Not Priced

Selected granular filling in bedding under and filling around pipes



Not Priced

4629

?mm Crushed stone bedding under pipes



Not Priced

4630

Unreinforced concrete bedding under pipes



Not Priced

4631

Class 16 uPVC pressure pipes with rubber ring joints

4632

?mm Pipes laid in and including trenches not exceeding 1m deep

m

Not Priced

4628

4633

Extra over class 16 uPVC pressure pipes for uPVC pressure fittings with rubber rings

4634

?mm Bend

No

Not Priced

4635

?mm Tee

No

Not Priced

4636

?mm BSP adaptor

No

Not Priced

4637

Extra over class 16 uPVC pressure pipes for cast iron pressure fittings

4638

?mm End cap

No

Not Priced

4639

?mm Reducer

No

Not Priced

4640

?mm Tee

No

Not Priced

4641

?mm Reducing tee

No

Not Priced

4642

?mm Saddle for ?mm branch, including nuts and bolts

No

Not Priced

4643

?mm Hydrant tee drilled to table 16, including connecting bolts, gaskets, etc

No

Not Priced

?mm Scour tee drilled to table 16, including connecting bolts, gaskets, etc

No

Not Priced

4644

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-301-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4645

?mm Flanged adaptor drilled to table 16, including connecting bolts, gaskets, etc

R

Not Priced

No

Not Priced

4646

Galvanised steel pipes

4647

?mm Pipes

m

Not Priced

4648

?mm Pipes chased into brickwork

m

Not Priced

4649

?mm Pipes laid in and including trenches not exceeding 1m deep

m

Not Priced

4650

Extra over galvanised steel pipes for steel fittings

4651

?mm Fittings

No

Not Priced

4652

?mm Bush

No

Not Priced

4653

?mm Elbow

No

Not Priced

4654

?mm Bend

No

Not Priced

4655

?mm Tee

No

Not Priced

4656

?mm Reducing tee

No

Not Priced

4657

?mm Longscrew connector

No

Not Priced

4658

?mm Union

No

Not Priced

4659

Sundries

4660

Unreinforced concrete in thrust blocks in trenches at bends, tees, etc, including extra excavation, formwork, etc



Not Priced

? x ? x ?mm x ?kg Cast iron stopcock box including brick chamber below ?mm deep internally

No

Not Priced

? x ? x ?mm x ?kg Cast iron meter box including brick chamber below ?mm deep internally

No

Not Priced

? x ?mm Brick valve chamber not exceeding ?mm deep internally including concrete kerb (cover and frame elsewhere)

No

Not Priced

? x ?mm x ?kg Cast iron single seal cover and frame

No

Not Priced

4661

4662

4663

4664

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-302-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4665

Municipal connection

4666

Provide the sum of R ? (? Rand) for municipal connection

Item

Not Priced

4667

Profit

Item

Not Priced

4668

Testing

4669

Testing fire water pipe system

Item

Not Priced

4670

PIPE PROTECTION

4671

"?" with ?% overlaps

4672

Wrapping around ?mm pipes, including couplings

4673

Extra over wrapping around pipes for wrapping around

4674

User note

4675

The following item applies only to fittings to pipes not exceeding 30mm diameter

4676

?mm Fittings, valves, etc

4677

User note

4678

The following items apply to fittings to pipes exceeding 30mm diameter

4679

m

Not Priced

No

Not Priced

?mm Bend

No

Not Priced

4680

?mm Tee

No

Not Priced

4681

?mm Valve

No

Not Priced

4682

PIPE INSULATION

4683

20mm Thick "?" pipe insulation

4684

"?" pipe insulation with plain covering

4685

"?" pipe insulation with canvas covering

4686

"?" pipe insulation with waterproof "?" covering

4687

Insulation to ?mm pipes including couplings

m

Not Priced

4688

Extra over pipe insulation for insulation around

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-303-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 4689

User note

4690

The following item applies only to fittings to pipes not exceeding 30mm diameter

4691

?mm Fittings, valves, etc

4692

User note

4693

The following items apply to fittings to pipes exceeding 30mm diameter

R

Not Priced

No

Not Priced

m

Not Priced

4694

?mm Bend

No

Not Priced

4695

?mm Tee

No

Not Priced

4696

?mm Valve

No

Not Priced

4697

FLUE PIPES ETC

4698

Fibre-cement flue pipes and fittings

4699

?mm Pipes

m

Not Priced

4700

Extra over ?mm pipe for bend

No

Not Priced

4701

Extra over ?mm pipe for access bend

No

Not Priced

4702

Cowl for ?mm pipe

No

Not Priced

4703

H-type cowl for ?mm pipe

No

Not Priced

4704

? x ?mm Flue liners

m

Not Priced

4705

Extra over ? x ?mm liner for bend

No

Not Priced

4706

SLEEVES

4707

0,6mm Galvanised sheet steel sleeves with welted seams for pipes not exceeding 100mm diameter

4708

Sleeve not exceeding 250mm long

No

Not Priced

4709

Sleeve exceeding ?mm and not exceeding ?mm long

No

Not Priced

Carried forward Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-304-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

4710

0,6mm Galvanised sheet steel sleeves with welted seams for pipes exceeding 100mm and not exceeding 200mm diameter

4711

Sleeve not exceeding 250mm long

No

Not Priced

4712

Sleeve exceeding ?mm and not exceeding ?mm long

No

Not Priced

4713

PVC sleeves for pipes not exceeding 100mm diameter

4714

Sleeve not exceeding 250mm long

No

Not Priced

4715

Sleeve exceeding ?mm and not exceeding ?mm long

No

Not Priced

4716

PVC sleeves for pipes exceeding 100mm and not exceeding 200mm diameter

4717

Sleeve not exceeding 250mm long

No

Not Priced

4718

Sleeve exceeding ?mm and not exceeding ?mm long

No

Not Priced

4719

HOLES ETC

4720

Core drilling hole not exceeding 50mm diameter

4721

Core drilling hole exceeding 50mm and not exceeding 100mm diameter

4722

Core drilling hole exceeding ?mm and not exceeding ?mm diameter

4723

?mm Thick reinforced concrete slab, beam, wall, etc

No

Not Priced

4724

AS-BUILT DRAWINGS

4725

Provision of as-built drawings

Item

Carried to summary Bill No 19 Plumbing and drainage ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-305-

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

5817

BILL NO ?

5818

ELECTRICAL WORK

5819

User note

5820

No provision has been made in the "Model Preambles" for electrical work. Users are therefore advised to include the engineer's comprehensive electrical project specification in these bills of quantities and to insert relevant supplementary preambles where necessary

Quantity

Rate

Amount

Supplementary preambles hereafter are given as examples only, reproduced from typical bills of quantities where some of the preambles may have been specifically required The range of items provided in this bill is an example of typical items with (or without) trade names to show possible ways of describing such items. Users must take special care that only items relevant to the specific project are to be included and that descriptions should be adapted as necessary to suit the particular circumstances Headings and descriptions of items in this bill assume that the specification and/or supplementary preambles fully describe materials to be used, methods of fixing, etc 5821

SUPPLEMENTARY PREAMBLES

5822

Specifications, drawings, etc

5823

Tenderers are referred to the specification and drawings numbered ? to ? prepared by ?, annexed to these bills of quantities (accompanying these bills of quantities?) for the electrical work, for the full descriptions of the following items which are to be read and priced in conjunction with the said specification and drawings

5824

Contract price adjustment provisions

5825

With reference to clause ? of the Preliminaries all items in this bill will be subject to fluctuations in the cost of labour and material on the following basis: (a) Ring main units, miniature substations, transformers, main low tension boards, distribution boards and busbars between transformer and low tension boards calculated on the indices published by the Steel and Engineering Industries Federation of South Africa

Carried forward Bill No 20 Electrical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-306-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5826

R

Not Priced

(b) Cables in excess of 16mm² calculated on the basis of proven cost (c) All other work calculated on the index for work group ?

5827

Distribution boards etc

5828

Rates for distribution boards etc are to include for busbars, jumpers, neutral bars, internal wiring and connections, circuit identification markers, control gear labels, circuit legend cards and working drawings

5829

Switches, socket outlets, etc

5830

Rates for switches, socket outlets, etc are to include for screwing to outlet boxes, connecting up and cover plates

5831

Light fittings

5832

Rates for light fittings are to include for hanging, fixing and connecting and for lamp holders and fluorescent tubes and lamps of the type and wattage described

5833

MUNICIPAL CONNECTION

5834

CONNECTION

5835

Provide the sum of R ? (? Rand) for municipal connection

Item

Not Priced

5836

Profit

Item

Not Priced

5837

Connection of 95mm² 3-core PEX cable with stranded copper conductors and 70mm² bare copper earth conductor to existing 11kV ring main supply cable, including required terminations and cable joints and making the necessary arrangements with the local authority

5838

HIGH TENSION DISTRIBUTION

5839

RING MAIN UNITS

5840

GEC T3/OF indoor type high tension ring main unit rated at 250MVA, 11kV 100A continuous with impulse with stand value of 95kVp and comprising two oil switches and one fuse switch unit of three 35A HRC fuses, installed on floor in substation

Carried forward Bill No 20 Electrical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-307-

No

Not Priced

No

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5841

GEC T4/OF indoor type high tension ring main unit rated at 250MVA, 11kV 100A continuous with impulse with stand value of 95kVp and comprising two oil switches and two fuse switch units each of three 100A HRC fuses, installed on floor in substation

5842

MINIATURE SUBSTATIONS

5843

?/400-231V Miniature substation with and including transformer, high and low voltage compartments with equipment, instrumentation, busbars, wiring and connections

5844

TRANSFORMERS

5845

Three-phase 630kVA 11kV/400V bulk oil transformer with ONAN cooling, approximately 2,5% and 5% tappings, off load top changer, 50Hz frequency, RYBR anti-clock phase rotation, DYN 11 vector group, group III testing requirements and three HT and four LV bushings suitable for indoor application in substation

5846

CABLES

5847

11kV PEX armoured cables laid in trenches or drawn through sleeve pipes (trenches and sleeve pipes elsewhere)

5848

?mm² ?-Core

5849

Cable joints

5850

?mm² ?-Core

5851

Cable terminations

5852

?mm² ?-Core

5853

EARTH CONDUCTORS

5854

Bare copper earth conductors laid with cable in trenches or sleeve pipes and bonded to cables with plastic strapping at 2m centres

5855

?mm²

5856

CABLE TRENCHES

Carried forward Bill No 20 Electrical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-308-

R

Not Priced

No

Not Priced

No

Not Priced

No

Not Priced

m

Not Priced

No

Not Priced

No

Not Priced

m

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5857

User note

5858

Where expedient cable trenches may be included in the description of the cable or group of cables (see Standard System Method "B")

5859

Excavation in earth not exceeding 2m deep for cable trenches including risk of collapse of excavations, keeping excavations free from water, setting aside excavated material and later refilling of trenches



Not Priced

Excavation in earth exceeding 2m and not exceeding 4m deep for cable trenches including risk of collapse of excavations, keeping excavations free from water, setting aside excavated material and later refilling of trenches



Not Priced

Extra over trench excavations in earth for excavation in soft rock



Not Priced

Extra over trench excavations in earth for excavation in hard rock



Not Priced

Extra over trench excavations for carting away surplus material to a dumping site to be located by the contractor



Not Priced

Extra over trench excavations for carting away surplus material to a dumping site situated approximately ?km from the building site



Not Priced

5860

5861

5862

5863

5864

5865

EARTHING

5866

Earth bar and all internal bonding and earthing of substation

5867

SUNDRIES

5868

Concrete block cable marker with inscribed aluminium or brass indicator plate

No

Not Priced

Concrete block cable joint marker with inscribed aluminium or brass indicator plate

No

Not Priced

Transformer room accessories comprising first aid kit, pair of rubber gloves and notices on door and inside the room complying with the Occupational Health and Safety Act, 1993

No

Not Priced

5869

5870

Carried forward Bill No 20 Electrical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-309-

Item

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5871

High tension room accessories comprising first aid kit, pair of rubber gloves and notices on door and inside the room complying with the Occupational Health and Safety Act, 1993

5872

LOW TENSION DISTRIBUTION

5873

MAIN LOW TENSION BOARD

5874

Freestanding type board in two panels with space for the following equipment and space for one additional 160A HRG fuse switch unit in panel 1

R

Not Priced

No

Not Priced

No

Not Priced

5875

Panel 1

5876

1000A Triple pole MCCB (25kA)

No

Not Priced

5877

1000/5A CT 5VA class CM

No

Not Priced

5878

0 - 100A Combined maximum demand and indicating type ammeter

No

Not Priced

5879

Voltmeter selector switch and set of HRC fuses

No

Not Priced

5880

0 - 400V Voltmeter

No

Not Priced

5881

1000A HCHD copper busbar with 70mm² earth bar

No

Not Priced

5882

Panel 2

5883

60A Fuse switch unit with three 60A HRC fuses

No

Not Priced

5884

100A Fuse switch unit with three 80A HRC fuses

No

Not Priced

5885

160A Fuse switch unit with three 160A HRC fuses

No

Not Priced

5886

1000A HCHD copper busbar with 70mm² earth bar

No

Not Priced

5887

DISTRIBUTION BOARD DB - ?

5888

Surface type floor mounted distribution board in three sections (normal, standby and uninterruptable power) without doors with space for the following equipment and 30% spare space to each section and with fourth section 500mm wide x 200mm deep x 600mm high for telephone equipment, fitted with doors and 20mm thick timber board on the inside to cover the full area, the board colour coded and installed in electrical cupboard

No

Not Priced

Carried forward Bill No 20 Electrical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-310-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

5889

Normal section

5890

60A Triple pole isolator

No

Not Priced

5891

2A Single pole MCCB (5kA)

No

Not Priced

5892

?A ? pole MCCB (?kA)

No

Not Priced

5893

20A Time switch with 72 hour spring reserve

No

Not Priced

5894

60A Single phase earth leakage unit (30mA)

No

Not Priced

5895

Standby section

5896

100A Triple pole isolator

No

Not Priced

5897

15A Single pole MCCB (5kA)

No

Not Priced

5898

?A ? pole MCCB (?kA)

No

Not Priced

5899

60A Single phase earth leakage unit (30mA)

No

Not Priced

5900

Uninterruptable power section

5901

60A Double pole isolator

No

Not Priced

5902

100A Triple pole isolator

No

Not Priced

5903

15A Single pole MCCB (5kA)

No

Not Priced

5904

?A ? pole MCCB (?kA)

No

Not Priced

5905

DISTRIBUTION BOARD DB - ?

5906

Flush mounted distribution board in one section (uninterruptable power) with door, space for the following equipment and space for ? additional circuit breakers, colour coded and installed in recess (elsewhere) in brick wall

No

Not Priced

5907

60A Triple pole isolator

No

Not Priced

5908

10A Single pole MCCB (5kA)

No

Not Priced

Carried forward Bill No 20 Electrical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-311-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5909

BUSBARS BETWEEN TRANSFORMER AND MAIN LOW TENSION BOARD

5910

1000A "Telemechanique KH2" busbars with full neutral and 60mm² earth bar supported from roof trusses with and including P4000 "Sankeystrut" sections with 9mm diameter bolts at approximately 1,5m centres

R

Not Priced

m

Not Priced

5911

Extra over for elbow

No

Not Priced

5912

End box between busbar and transformer

No

Not Priced

5913

End box between busbar and main low tension board

No

Not Priced

5914

CABLES

5915

"Cabtyre" cables laid loose on surface beds in floor ducts

5916

"Cabtyre" cables drawn into conduits

5917

600/1000V PVC/PVC/SWA/PVC copper cable laid in trenches or drawn through sleeve pipes (trenches and sleeve pipes elsewhere)

5918

?mm² ?-Core

m

Not Priced

5919

Cable joints

5920

?mm² ?-Core

No

Not Priced

5921

Cable terminations

5922

?mm² ?-Core

No

Not Priced

5923

EARTH CONDUCTORS

5924

Bare copper earth conductors laid with cable in trenches or sleeve pipes and bonded to cables with plastic strapping at 2m centres

5925

PVC insulated copper earth conductors laid with cables in trenches or sleeve pipes and bonded to cables with plastic strapping at 2m centres

5926

?mm²

m

Not Priced

5927

CABLE TRAYS

Carried forward Bill No 20 Electrical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-312-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5928

Galvanised heavy duty cable trays, including short lengths and fixed to walls

5929

?mm Wide cable trays

5930

Extra over for

5931

R

Not Priced

m

Not Priced

External elbow (dropper)

No

Not Priced

5932

Internal elbow (riser)

No

Not Priced

5933

Horizontal elbow (bend)

No

Not Priced

5934

Concentric reducer

No

Not Priced

5935

Eccentric reducer

No

Not Priced

5936

Tee

No

Not Priced

5937

Four-way junction

No

Not Priced

5938

CABLE LADDERS

5939

?mm Wide cable ladders

m

Not Priced

5940

Extra over for

5941

External elbow (dropper)

No

Not Priced

5942

Internal elbow (riser)

No

Not Priced

5943

Horizontal elbow (bend)

No

Not Priced

5944

Concentric reducer

No

Not Priced

5945

Eccentric reducer

No

Not Priced

5946

Tee

No

Not Priced

5947

Four-way junction

No

Not Priced

5948

CABLE TRENCHES

5949

User note

5950

Where expedient cable trenches may be included in the description of the cable or group of cables (see Standard System Method "B")

Carried forward Bill No 20 Electrical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-313-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5951

5952

5953

5954

5955

5956

R

Not Priced

Excavation in earth not exceeding 2m deep for cable trenches including risk of collapse of excavations, keeping excavations free from water, setting aside excavated material and later refilling of trenches



Not Priced

Excavation in earth exceeding 2m and not exceeding 4m deep for cable trenches including risk of collapse of excavations, keeping excavations free from water, setting aside excavated material and later refilling of trenches



Not Priced

Extra over trench excavations in earth for excavation in soft rock



Not Priced

Extra over trench excavations in earth for excavation in hard rock



Not Priced

Extra over trench excavations for carting away surplus material to a dumping site to be located by the contractor



Not Priced

Extra over trench excavations for carting away surplus material to a dumping site situated approximately ?km from the building site



Not Priced

5957

SUNDRIES

5958

Concrete block cable marker with inscribed aluminium or brass indicator plate

No

Not Priced

Concrete block cable joint marker with inscribed aluminium or brass indicator plate

No

Not Priced

Low tension room accessories comprising first aid kit, pair of rubber gloves and notices on door and inside the room complying with the Occupational Health and Safety Act, 1993

No

Not Priced

5959

5960

5961

GENERAL LIGHTING AND POWER

5962

CONDUITS ETC

5963

User note

5964

The type of conduit to be used will usually be specified in the engineer's specification

5965

Black enamelled steel conduits

5966

Galvanised steel conduits

Carried forward Bill No 20 Electrical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-314-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5967

Rigid PVC conduits

5968

?mm Diameter

5969

Flexible conduits

5970 5971

R

Not Priced

m

Not Priced

?mm Diameter flexible PVC conduit ?m long

No

Not Priced

?mm Diameter galvanised steel flexible conduit with PVC sheath, ?m long

No

Not Priced

5972

Black enamelled conduit accessories

5973

Galvanised steel conduit accessories

5974

PVC conduit accessories

5975

Round outlet box for ?mm conduit

No

Not Priced

5976

Deep type (concrete type) round outlet box for ?mm conduit

No

Not Priced

5977

Standard draw box for ?mm conduit

No

Not Priced

5978

50 x 100 x 50mm Outlet box

No

Not Priced

5979

100 x 100 x 50mm Outlet box

No

Not Priced

5980

100 x 100 x 50mm Outlet box with blank cover plate

No

Not Priced

5981

WIRING CHANNELS

5982

Type ? galvanised wiring channels fitted with full length cover plates and cast into concrete surface beds

m

Not Priced

Type ? galvanised wiring channels fitted with full length cover plates and fixed to walls

m

Not Priced

5983

5984

Extra over for

5985

Pre-punched opening for socket outlet

No

Not Priced

5986

Elbow

No

Not Priced

5987

Tee intersection

No

Not Priced

5988

Cross intersection

No

Not Priced

5989

Closed end to wiring channel

No

Not Priced

Carried forward Bill No 20 Electrical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-315-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 5990

POWER SKIRTINGS

5991

Type ? two tier three compartment power skirtings with powder coated finish, fixed to walls

R

Not Priced

m

Not Priced

5992

Extra over for

5993

T-intersection

No

Not Priced

5994

Internal corner piece

No

Not Priced

5995

End cap

No

Not Priced

5996

16A Three pin flush mounted socket outlet with switch, fixed to skirting

No

Not Priced

16A Three pin flush mounted socket outlet with switch and flat earth pin, fixed to skirting

No

Not Priced

m

Not Priced

m

Not Priced

5997

5998

CONDUCTORS

5999

Bare copper conductors drawn into conduit, trunking or power skirting

6000

PVC insulated stranded copper conductors drawn into conduit, trunking or power skirting

6001

Heat resistant silicon insulated stranded copper conductors drawn into conduit, trunking or power skirting

6002

?mm²

6003

DRAW-WIRES

6004

Galvanised steel draw-wires drawn into conduit

6005

LIGHT SWITCHES, SOCKET OUTLETS, ETC

6006

Flush mounted bell push button

No

Not Priced

6007

16A Flush mounted one lever one-way switch unit

No

Not Priced

6008

16A Flush mounted two lever one-way switch unit

No

Not Priced

6009

16A Flush mounted three lever one-way switch unit

No

Not Priced

6010

16A Flush mounted four lever one-way switch unit

No

Not Priced

Carried forward Bill No 20 Electrical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-316-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 6011

R

Not Priced

16A Flush mounted one lever one-way switch unit with neon light

No

Not Priced

6012

16A Flush mounted one lever two-way switch unit

No

Not Priced

6013

16A Flush mounted two lever two-way switch unit

No

Not Priced

6014

16A Flush mounted two lever with one one-way and one two-way switch unit

No

Not Priced

16A Flush mounted three lever with two one-way and one two-way switch unit

No

Not Priced

6016

16A Flush mounted one lever intermediate switch unit

No

Not Priced

6017

16A Flush mounted one lever one-way dimmer control switch unit (2kW)

No

Not Priced

16A Flush mounted two lever one-way dimmer control switch unit (2kW)

No

Not Priced

6019

5A Three pin flush mounted socket outlet without switch

No

Not Priced

6020

16A Surface mounted one lever one-way industrial type switch unit

m

Not Priced

16A Surface mounted one lever two-way industrial type switch unit

No

Not Priced

16A Three pin flush mounted socket outlet with switch, single type

No

Not Priced

16A Three pin flush mounted socket outlet with switch, double type

No

Not Priced

16A Three pin flush mounted socket outlet with switch and flat earth pin, single type

No

Not Priced

16A Three pin surface mounted industrial type socket outlet with switch and flat earth pin, single type

No

Not Priced

6026

20A Flush mounted double pole isolator

No

Not Priced

6027

40A Flush mounted double pole isolator

No

Not Priced

6028

30A Flush mounted triple pole isolator

No

Not Priced

6029

60A Flush mounted triple pole isolator

No

Not Priced

6015

6018

6021

6022

6023

6024

6025

Carried forward Bill No 20 Electrical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-317-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

6030

20A Surface mounted double pole isolator

No

Not Priced

6031

40A Surface mounted double pole isolator

No

Not Priced

6032

30A Surface mounted triple pole isolator

No

Not Priced

6033

60A Surface mounted triple pole isolator

No

Not Priced

6034

LUMINAIRES

6035

Lascon V1-100BC/C/Plas economy injection moulded polycarbonate luminaire with 100W GLS lamp

No

Not Priced

Lascon "Britelite" B10-2-D/DS/CL bulkhead type light fitting with 16W 2-D fluorescent lamp and control gear

No

Not Priced

Lascon "Bollard" 4Bo14-80MV bollard light fitting with 80W MV lamp and ballast and setting on concrete base (elsewhere)

No

Not Priced

6036

6037

6038

CONNECTIONS OF APPLIANCES ETC

6039

Take delivery, store temporarily, unpack, place in position and connect electric stove (isolator, conductors, conduit and flexible conduit elsewhere)

No

Not Priced

Connecting geyser (elsewhere) to isolator with and including 3mm² ?-core PVC insulated cable not exceeding 1m long

No

Not Priced

6040

6041

SUNDRIES

6042

Earthing of buildings

Item

Not Priced

6043

Provision of as built drawings

Item

Not Priced

6044

Testing and commissioning the complete electrical installation

Item

Not Priced

6045

ACCESS CONTROL

6046

?mm Diameter conduits

6047

m

Not Priced

Round outlet box for ?mm conduit

No

Not Priced

6048

100 x 100 x 50mm Outlet box

No

Not Priced

6049

200 x 200 x 50mm Outlet box

No

Not Priced

Carried forward Bill No 20 Electrical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-318-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 6050

TELEPHONE OUTLETS

6051

?mm Conduits including galvanised steel draw wire drawn into conduit

R

Not Priced

m

Not Priced

6052

Standard draw box for ?mm conduit

No

Not Priced

6053

50 x 100 x 50mm Flush mounted outlet box

No

Not Priced

6054

100 x 100 x 50mm Flush mounted outlet box with cover plate with 10mm hole and grommet for cabling to pass through

No

Not Priced

No

Not Priced

6055

UNINTERRUPTABLE POWER SOURCE

6056

220V 5kVA unit with 30 minute batteries

Carried to summary Bill No 20 Electrical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-319-

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

6333

BILL NO ?

6334

MECHANICAL WORK

6335

User note

6336

No provision has been made in the "Model Preambles" for mechanical work. Users are therefore advised to include the engineer's comprehensive mechanical project specification in these bills of quantities and to insert relevant supplementary preambles where necessary

Quantity

Rate

Amount

Supplementary preambles hereafter are given as examples only, reproduced from typical bills of quantities where some of the preambles may have been specifically required The range of items provided in this bill is an example of typical items with (or without) trade names to show possible ways of describing such items. Users must take special care that only items relevant to the specific project are to be included and that descriptions should be adapted as necessary to suit the particular circumstances Headings and descriptions of items in this bill assume that the specification and/or supplementary preambles fully describe materials to be used, methods of fixing, etc 6337

SUPPLEMENTARY PREAMBLES

6338

Specifications, drawings, etc

6339

Tenderers are referred to the specification and drawings numbered ? to ? prepared by ?, annexed to these bills of quantities (accompanying these bills of quantities?) for the mechanical work, for the full descriptions of the following items which are to be read and priced in conjunction with the said specification and drawings

6340

Ductwork

6341

Descriptions of ducts shall be deemed to include stiffeners, jointing materials, sealants, couplers in the running length and access/inspection panels in accordance with the specification

6342

Dampers

6343

Descriptions of smoke and fire dampers shall be deemed to include fusible links, sleeves, frames, supports and access openings in ducts

Carried forward Bill No 21 Mechanical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-320-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 6344

Air diffusion

6345

Descriptions of air terminals, grilles, louvres and the like shall be deemed to include necks, frames, supports and flexible connections

6346

Fans

6347

Descriptions of fan assemblies shall be deemed to include supports from the structure, flexible or other connections to ductwork, vibration isolation mountings and airtight inspection doors

6348

Sound attenuators

6349

Descriptions of sound attenuators shall be deemed to include flanged or flexible connections to ducts and supports from the structure

6350

Fan coil units, fan air terminals and fan heaters

6351

Descriptions of fan coil units, fan air terminals and fan heaters shall be deemed to include connection points for water, air and electrical supply, for air grilles, dust trays, condensate trays and vibration isolation mountings. Flexible ducts, flexible hose and connecting cables for connecting these units to each other or to water pipe, and electrical supply are separately measured

6352

Major equipment

6353

Descriptions of major equipment such as chillers, air handling units and the like shall be deemed to include connections to water, air and electrical supply and/or discharge points, supports, bearers, vibration insulation mountings, filters, insulation, inspection ladders and gangways, access doors and panels and painting etc as specified

Carried forward Bill No 21 Mechanical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-321-

R

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 6354

Piping

6355

Pipe diameters are nominal internal unless otherwise stated

R

Not Priced

Where fittings have reducing ends or branches they are described as "reducing". In the case of pipes with diameters not exceeding 60mm only the largest end or branch diameter is given. Should the contractor wish to use other fittings and bushes or reducers he may do so on the understanding that no claim in this regard will be entertained. In the case of pipes with diameters exceeding 60mm all diameters are given and no claim for extra bushes, reducers, etc will be entertained 6356

Fixing of pipes

6357

Unless otherwise stated, descriptions of pipes shall be deemed to include fixing to walls etc, casting in, building in or suspending not exceeding 1m below suspension level

6358

Pump sets

6359

Descriptions of pumps shall be deemed to include connections to water and electrical supply and/or discharge points, vibration insulation mountings, insulation, drip trays with outlets, pressure gauges, etc

6360

Valves

6361

Descriptions of valves shall be deemed to include flanged or screwed connections to pipes, reducers, supports, etc

6362

Insulation

6363

Descriptions of insulation shall be deemed to include priming the pipes with zinc chromate primer before the insulation is applied, painting the insulation when completed and applying vapour barrier where specified

6364

AIR CONDITIONING INSTALLATION

6365

"SPLIT TYPE" UNITS

6366

?kW Wall mounted unit with condensor section mounted on external wall

No

Not Priced

?kW Wall mounted unit with refrigerant and drain piping, with condensor section mounted on external wall

No

Not Priced

6367

Carried forward Bill No 21 Mechanical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-322-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

6368

SUPPLY DUCTWORK

6369

EXTRACT DUCTWORK

6370

Rectangular galvanised sheet metal low pressure ducting (supports elsewhere)

6371

Rectangular galvanised sheet metal internally insulated low pressure ducting (supports elsewhere)

6372

Category ? ducting



Not Priced

6373

Category ? ducting curved across width to ?mm mean radius



Not Priced

6374

Rectangular galvanised sheet metal low pressure ducting including supports

6375

Rectangular galvanised sheet metal internally insulated low pressure ducting including supports

6376

Category ? ducting fixed to walls etc



Not Priced

6377

Category ? ducting suspended not exceeding 1m below concrete soffits



Not Priced

Category ? ducting suspended exceeding ?m and not exceeding ?m below concrete soffits



Not Priced

Category ? ducting suspended exceeding 1m below steel roof trusses at ?m centres



Not Priced

Category ? ducting suspended exceeding ?m and not exceeding ?m below steel roof trusses at ?m centres



Not Priced

Category ? ducting curved across width to ?mm mean radius, fixed to walls etc



Not Priced

Category ? ducting curved across width to ?mm mean radius, suspended not exceeding 1m below concrete soffits



Not Priced

m

Not Priced

6378

6379

6380

6381

6382

6383

Galvanised sheet metal ducting (supports elsewhere)

6384

Stainless steel ducting (supports elsewhere)

6385

Galvanised sheet metal internally insulated ducting (supports elsewhere)

6386

? x ?mm Ducting

Carried forward Bill No 21 Mechanical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-323-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

6387

? x ?mm Ducting curved across width to ?mm mean radius

m

Not Priced

6388

?mm Diameter ducting

m

Not Priced

6389

?mm Diameter ducting curved to ?mm mean radius

m

Not Priced

6390

Galvanised sheet metal ducting including supports

6391

Stainless steel ducting including supports

6392

Galvanised sheet metal internally insulated ducting including supports

6393

? x ?mm Ducting fixed to walls etc

m

Not Priced

6394

? x ?mm Ducting suspended not exceeding 1m below concrete soffits

m

Not Priced

? x ?mm Ducting suspended exceeding ?m and not exceeding ?m below concrete soffits

m

Not Priced

? x ?mm Ducting suspended not exceeding 1m below steel roof trusses at ?m centres

m

Not Priced

? x ?mm Ducting suspended exceeding ?m and not exceeding ?m below steel roof trusses at ?m centres

m

Not Priced

? x ?mm Ducting curved across width to ?mm mean radius, fixed to walls etc

m

Not Priced

? x ?mm Ducting curved across width to ?mm mean radius, suspended not exceeding 1m below concrete soffits

m

Not Priced

? x ?mm Ducting curved across width to ?mm mean radius, suspended exceeding ?m and not exceeding ?m below concrete soffits

m

Not Priced

? x ?mm Ducting curved across width to ?mm mean radius, suspended not exceeding 1m below steel roof trusses at ?m centres

m

Not Priced

? x ?mm Ducting curved across width to ?mm mean radius, suspended exceeding ?m and not exceeding ?m below steel roof trusses at ?m centres

m

Not Priced

6403

?mm Diameter ducting fixed to walls etc

m

Not Priced

6404

?mm Diameter ducting suspended not exceeding 1m below concrete soffits

m

Not Priced

6395

6396

6397

6398

6399

6400

6401

6402

Carried forward Bill No 21 Mechanical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-324-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 6405

6406

6407

6408

6409

6410

6411

6412

R

Not Priced

?mm Diameter ducting suspended exceeding ?m and not exceeding ?m below concrete soffits

m

Not Priced

?mm Diameter ducting suspended not exceeding 1m below steel roof trusses at ?m centres

m

Not Priced

?mm Diameter ducting suspended exceeding ?m and not exceeding ?m below steel roof trusses at ?m centres

m

Not Priced

?mm Diameter ducting circular to ?mm mean radius, fixed to walls etc

m

Not Priced

?mm Diameter ducting circular to ?mm mean radius, suspended not exceeding 1m below concrete soffits

m

Not Priced

?mm Diameter ducting circular to ?mm mean radius, suspended exceeding ?m and not exceeding ?m below concrete soffits

m

Not Priced

?mm Diameter ducting circular to ?mm mean radius, suspended not exceeding 1m below steel roof trusses at ?m centres

m

Not Priced

?mm Diameter ducting circular to ?mm mean radius, suspended exceeding ?m and not exceeding ?m below steel roof trusses at ?m centres

m

Not Priced

6413

Extra over galvanised sheet metal low pressure ducting for

6414

Extra over stainless steel low pressure ducting for

6415

Extra over galvanised sheet metal internally insulated low pressure ducting for

6416

Category ? ducting

6417

Stopped end

No

Not Priced

6418

Reducer, radius bend, square bend, transformation, spigot, branch or tee

No

Not Priced

6419

Square bend with vanes

No

Not Priced

6420

Tee with vanes

No

Not Priced

6421

? x ?mm Ducting

6422

Stopped end

No

Not Priced

Carried forward Bill No 21 Mechanical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-325-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 6423

R

Not Priced

Reducer, radius bend, square bend, transformation, spigot, branch or tee

No

Not Priced

6424

Square bend with vanes

No

Not Priced

6425

Tee with vanes

No

Not Priced

6426

?mm Diameter ducting

6427

Stopped end

No

Not Priced

6428

Reducer, radius bend, square bend, transformation, spigot, branch or tee

No

Not Priced

6429

Uninsulated flexible ducting

6430

Insulated flexible ducting

6431

?mm Diameter ducting not exceeding 1,5m girth, including connections to ducting or equipment

No

Not Priced

?mm Diameter ducting exceeding ?m and not exceeding ?m girth, including connections to ducting or equipment

No

Not Priced

6432

6433

Supports for ducting comprising ?

6434

? x ?mm Ducting

m

Not Priced

6435

?mm Diameter ducting

m

Not Priced

6436

DUCTING INSULATION

6437

External insulation

6438

?mm Thick insulation



Not Priced

6439

?mm Thick insulation with sheet metal covering



Not Priced

6440

Internal insulation

6441

?mm Thick insulation



Not Priced

6442

DIFFUSERS, GRILLES, ETC

6443

Anodised aluminium door grilles

6444

? x ?mm Door grille

No

Not Priced

6445

Powder coated aluminium supply diffusers

Carried forward Bill No 21 Mechanical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-326-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

6446

Anodised aluminium supply diffusers

6447

? x ?mm Constant volume air terminal mounted on end of duct or spigot

No

Not Priced

6448

? x ?mm Constant volume side-wall mounted air terminal

No

Not Priced

6449

? x ?mm Constant volume ceiling mounted air terminal

No

Not Priced

6450

? x ?mm Constant volume floor mounted air terminal

No

Not Priced

6451

? x ?mm Variable volume side-wall mounted air terminal

No

Not Priced

6452

? x ?mm Variable volume ceiling mounted air terminal

No

Not Priced

6453

? x ?mm Variable volume floor mounted air terminal

No

Not Priced

6454

? x ?mm Variable volume side-wall mounted air terminal with ?kW heater

No

Not Priced

? x ?mm Variable volume ceiling mounted air terminal with ?kW heater

No

Not Priced

6455

6456

Anodised aluminium extract, transfer and return air grilles

6457

? x ?mm Ceiling mounted return air grille

No

Not Priced

6458

? x ?mm Ceiling mounted return air grille with opposed blade damper

No

Not Priced

6459

? x ?mm Return air grille mounted on end of duct or spigot

No

Not Priced

6460

? x ?mm Grille mounted in opening in concrete or brickwork

No

Not Priced

6461

Mesh grilles

6462

? x ?mm Wire mesh grille mounted in opening in brickwork or concrete

No

Not Priced

6463

? x ?mm Expanded metal grille fixed on end of duct

No

Not Priced

6464

Natural anodised aluminium weather louvres

6465

? anodised aluminium weather louvres

6466

? x ?mm Weather louvre with wire mesh screen, mounted on end of duct

No

Not Priced

Carried forward Bill No 21 Mechanical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-327-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 6467

? x ?mm Weather louvre with wire mesh screen, mounted in opening in concrete or brickwork

R

Not Priced

No

Not Priced

6468

DUCTING SUNDRIES

6469

Sound attenuators

6470

?mm Diameter attenuator to ? x ?mm duct

No

Not Priced

6471

?mm Diameter attenuator to ?mm diameter duct

No

Not Priced

6472

Dampers

6473

? x ?mm Pneumatically operated volume control damper

No

Not Priced

6474

? x ?mm Fire damper with fusible link

No

Not Priced

6475

? x ?mm Static pressure control damper

No

Not Priced

6476

Filters

6477

? x ?mm Filter bank

No

Not Priced

6478

EQUIPMENT

6479

Fans

6480

Propeller fan ? litres/second complete with louvre shutter

No

Not Priced

6481

In-line tube duct fan ? litres/second

No

Not Priced

6482

In-line rectangular duct fan ? litres/second

No

Not Priced

6483

Vane-axial fan ? litres/second

No

Not Priced

6484

Fan air terminals

6485

Ceiling mounted fan air terminal ? litres/second

No

Not Priced

6486

Floor mounted fan air terminal ? litres/second

No

Not Priced

6487

Fan heaters

6488

?kW Ceiling mounted fan heater

No

Not Priced

6489

?kW Floor mounted fan heater

No

Not Priced

Carried forward Bill No 21 Mechanical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-328-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

6490

Fan coil units

6491

Ceiling mounted chilled water fan coil unit ? litres/second

No

Not Priced

6492

Floor mounted chilled water fan coil unit ? litres/second

No

Not Priced

6493

Ceiling mounted chilled water fan coil unit ? litres/second with ?kW heater

No

Not Priced

Floor mounted chilled water fan coil unit ? litres/second with ?kW heater

No

Not Priced

No

Not Priced

No

Not Priced

6494

6495

Air handling units

6496

Air handling unit type ?

6497

Cooling towers

6498

Cooling tower type ?

6499

CONDENSER WATER PIPEWORK ETC

6500

CHILLED WATER PIPEWORK ETC

6501

Class ? black steel pipes with screwed and socketed joints (pipe supports elsewhere)

6502

Class ? black steel pipes with screwed and socketed joints

6503

Class ? galvanised steel pipes with screwed and socketed joints (pipe supports elsewhere)

6504

Class ? galvanised steel pipes with screwed and socketed joints

6505

?mm Pipes

m

Not Priced

6506

?mm Pipes chased into brickwork including brown paper lagging

m

Not Priced

?mm Pipes suspended exceeding ?m and not exceeding ?m below concrete soffits

m

Not Priced

?mm Pipes suspended exceeding ?m and not exceeding ?m below steel roof trusses at ?mm centres

m

Not Priced

6507

6508

6509

Extra over class ? black steel pipes for fittings

6510

Extra over class ? galvanised steel pipes for fittings

Carried forward Bill No 21 Mechanical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-329-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 6511

User note

6512

The following item applies only to fittings to pipes not exceeding 60mm diameter

6513

?mm Fittings

6514

User note

6515

The following items apply to fittings to pipes exceeding 60mm diameter

6516

R

Not Priced

No

Not Priced

?mm Plug

No

Not Priced

6517

?mm Bush

No

Not Priced

6518

?mm Elbow

No

Not Priced

6519

?mm Bend

No

Not Priced

6520

?mm Tee

No

Not Priced

6521

?mm Reducing tee

No

Not Priced

6522

? x ? x ?mm Reducing tee

No

Not Priced

6523

?mm Longscrew connector

No

Not Priced

6524

?mm Union

No

Not Priced

6525

?mm "Johnson" coupling

No

Not Priced

6526

?mm Single screwed flange complete with gasket and bolts

No

Not Priced

6527

Class ? black steel pipes with and including welded flange joints (pipe supports elsewhere)

6528

Class ? black steel pipes with and including welded flange joints

6529

Class ? black steel pipes with welded flange joints (flanges and pipe supports elsewhere)

6530

Class ? black steel pipes with welded flange joints (flanges elsewhere)

6531

Class ? galvanised steel pipes with and including welded flange joints (pipe supports elsewhere)

Carried forward Bill No 21 Mechanical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-330-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

6532

Class ? galvanised steel pipes with and including welded flange joints

6533

Class ? galvanised steel pipes with welded flange joints (flanges and pipe supports elsewhere)

6534

Class ? galvanised steel pipes with welded flange joints (flanges elsewhere)

6535

?mm Pipes

m

Not Priced

6536

?mm Pipes chased into brickwork including brown paper lagging

m

Not Priced

?mm Pipes suspended exceeding ?m and not exceeding ?m below concrete soffits

m

Not Priced

m

Not Priced

6537

6538

?mm Pipes suspended exceeding ?m and not exceeding ?m below steel roof trusses at ?mm centres

6539

Extra over class ? black steel pipes for

6540

Extra over class ? galvanised steel pipes for

6541

Blank welded flange for ?mm pipe complete with gasket and bolts

No

Not Priced

Single welded flange for ?mm pipe complete with gasket and bolts

No

Not Priced

Pair of welded flanges for ?mm pipe complete with gasket and bolts

No

Not Priced

No

Not Priced

6542

6543

6544

Extra over class ? black steel pipes for fittings with welded flanges

6545

Extra over class ? galvanised steel pipes for fittings with welded flanges

6546

User note

6547

The following item applies only to fittings to pipes not exceeding 60mm diameter

6548

?mm Fittings

Carried forward Bill No 21 Mechanical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-331-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

6549

User note

6550

The following items apply to fittings to pipes exceeding 60mm diameter

6551

? x ?mm Reducer

No

Not Priced

6552

?mm Elbow

No

Not Priced

6553

?mm Tee

No

Not Priced

6554

? x ? x ?mm Reducing tee

No

Not Priced

6555

User note

6556

The following two sub-headings and three items apply only to purpose made pipe supports

6557

Supports for pipes comprising ?

6558

?mm Pipe

m

Not Priced

6559

Supports for sets of pipes in vertical shafts comprising ?

6560

Set of two ?mm pipes

m

Not Priced

6561

Set of ? ?mm pipes

m

Not Priced

6562

Valves etc with screwed or flanged ends

6563

?mm Gate valve

No

Not Priced

6564

?mm Butterfly valve

No

Not Priced

6565

?mm Globe valve

No

Not Priced

6566

?mm Balancing valve

No

Not Priced

6567

?mm Solenoid valve

No

Not Priced

6568

?mm Automatic air release valve

No

Not Priced

6569

?mm Drain valve

No

Not Priced

6570

?mm Remote motor controlled valve

No

Not Priced

6571

Pressure gauge and stopcock

No

Not Priced

6572

?mm Pocket type thermometer

No

Not Priced

Carried forward Bill No 21 Mechanical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-332-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 6573

?mm Strainer

6574

PIPE INSULATION

6575

Insulation to concealed pipes including vapour barrier

6576

Insulation to exposed pipes including vapour barrier, sheet metal cladding and painting

6577

?mm Pipes

6578

Extra over insulation to concealed pipes for insulation to

6579

Extra over insulation to exposed pipes for insulation to

6580

User note

6581

The following item applies only to fittings to pipes not exceeding 60mm diameter

6582

?mm Fittings, valves, etc

6583

User note

6584

The following items apply to fittings to pipes exceeding 60mm diameter

6585

R

Not Priced

No

Not Priced

m

Not Priced

No

Not Priced

?mm Plug

No

Not Priced

6586

?mm Reducer

No

Not Priced

6587

?mm Elbow or bend

No

Not Priced

6588

?mm Tee or reducing tee

No

Not Priced

6589

?mm Single flange

No

Not Priced

6590

?mm Pair of flanges

No

Not Priced

6591

?mm Valve

No

Not Priced

6592

FLEXIBLE HOSES

6593

?mm Normal duty flexible rubber hose ?m long complete with fittings to connect one end to drip pan and other end to drain pipe

No

Not Priced

Carried forward Bill No 21 Mechanical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-333-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 6594

?mm Heavy duty flexible rubber hose ?m long complete with fittings to connect one end to fan coil unit and other end to distribution pipe

R

Not Priced

No

Not Priced

6595

PUMPS

6596

Chilled water pump type ?

No

Not Priced

6597

Condenser water pump type ?

No

Not Priced

6598

WATER CHILLERS

6599

Water chiller type ?

No

Not Priced

6600

GENERAL

6601

User note

6602

Refer to Plumbing and Drainage for additional items applicable to pipework etc such as encasing, anchor blocks, inspection chambers, etc Refer to Electrical Work for items applicable to integral electrical work which are to be included in this bill

6603

Testing and commisioning the installation

Item

Not Priced

6604

Provision of as-built drawings, manuals and operative training

Item

Not Priced

6605

Replacement parts

Item

Not Priced

6606

Comprehensive maintenance during the 12-month guarantee period

Item

Not Priced

6607

LIFT INSTALLATION

6608

The following in ? passenger lift (lifts?) and ? service lift (lifts?) each serving ? floors with stops at all floors

6609

Passenger lift car including frame, guides, enclosure, base, car door, inspection door, sill, internal finishes, handrails, lighting and ventilation

No

Not Priced

Service lift car including frame, guides, enclosure, base, car door, inspection door, sill, internal finishes, handrails, lighting and ventilation

No

Not Priced

6610

Carried forward Bill No 21 Mechanical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-334-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 6611

6612

6613

6614

6615

R

Not Priced

Landing entrance to passenger lift including frame and building in, sill, landing doors, door opening devices, locking and safety devices, etc

No

Not Priced

Landing entrance to service lift including frame and building in, sill, landing doors, door opening devices, locking and safety devices, etc

No

Not Priced

Power unit to passenger lift including supports, sheaves, sound reducing material, switching equipment, etc

No

Not Priced

Power unit to service lift including supports, sheaves, sound reducing material, switching equipment, etc

No

Not Priced

Support work in lift shaft for ? passenger lift (lifts?) and ? service lift (lifts?) including guard rails, brackets, plates, buffers, supports, sheave beams, etc

Item

Not Priced

Ropes for ? passenger lift (lifts?) including cables, clamps, etc

Item

Not Priced

6617

Ropes for ? service lift (lifts?) including cables, clamps, etc

Item

Not Priced

6618

Counterweights to ? passenger lift (lifts?) including frames, guides, compensation, etc

Item

Not Priced

Counterweights to ? service lift (lifts?) including frames, guides, compensation, etc

Item

Not Priced

6620

Governors and safety gear to ? passenger lift (lifts?)

Item

Not Priced

6621

Governors and safety gear to ? service lift (lifts?)

Item

Not Priced

6622

Operation and control system comprising car operator panels, car position and direction indicators, landing position and direction indicators, call buttons, lanterns and gongs, load weighing devices, intercommunication, detectors, wiring, etc to all lifts

Item

Not Priced

Temporary use of service lift comprising temporary enclosures, protection, finishes, etc, refurbishment, completion and re-commissioning

Item

Not Priced

6616

6619

6623

Carried to summary Bill No 21 Mechanical work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-335-

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

2535

BILL NO ?

2536

GLAZING

2537

SUPPLEMENTARY PREAMBLES

2538

Float glass

2539

The term "float glass" is used for monolithic annealed glass

2540

Laminated glass

2541

Laminated glass to have polyvinyl butyral (PVB) interlayer(s)

Quantity

Rate

Amount

GLAZING TO STEEL WITH PUTTY GLAZING TO STEEL WITH SCREWED-ON BEADS (BEADS ELSEWHERE) GLAZING TO ALUMINIUM WITH SCREWED-ON BEADS (BEADS ELSEWHERE) GLAZING TO ALUMINIUM WITH CLIP-ON BEADS (BEADS ELSEWHERE) GLAZING TO WOOD WITH PUTTY GLAZING TO WOOD WITH PINNED-ON BEADS (BEADS ELSEWHERE) 2548

?mm Clear float glass

2549

?mm (Colour?) tinted float glass

2550

?mm Type ? coated float glass

2551

?mm Type ? obscure glass

2552

?mm Georgian wired rough cast glass

2553

?mm Georgian wired polished glass

2554

?mm Clear toughened safety glass ?mm Normal strength (NS) clear laminated safety glass ?mm Normal strength (NS) type ? tinted laminated safety glass

Carried forward Bill No 22 Glazing ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-336-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

?mm Normal strength (NS) type ? coated laminated safety glass 2558

User note

2559

HPR glass usually has two layers of vinyl interlayer and HI glass four layers ?mm High penetration resistance (HPR) clear laminated safety glass ?mm High penetration resistance (HPR) type ? tinted laminated safety glass

2562

?mm High penetration resistance (HPR) type ? coated laminated safety glass

2563

?mm High impact (HI) clear laminated safety glass

2564

?mm High impact (HI) type ? tinted laminated safety glass

2565

?mm High impact (HI) type ? coated laminated safety glass

2566

?mm (Colour?) normal strength (NS) laminated performance glass (light transmission ?%, shading co-efficient ?, U-value ?)

2567

?mm Type ? double glazed sealed units

2568

?mm Double glazed sealed units with dry air (type ? inert gas?) in cavity between sheets, of ?mm clear toughened float glass on inside and ?mm type ? normal strength (NS) clear laminated safety glass on outside

2569

User note

2570

Double glazed units are available in many glass type combinations with air cavities filled with dry air or inert gases

2571

Panes not exceeding 0,1m²



Not Priced

2572

Panes exceeding 0,1m² and not exceeding 0,5m²



Not Priced

2573

Panes exceeding 0,5m² and not exceeding 2m²



Not Priced

2574

Panes exceeding 2m² and not exceeding 4m²



Not Priced

2575

Panes exceeding ?m² and not exceeding ?m²



Not Priced

Carried forward Bill No 22 Glazing ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-337-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2576

2577

2578

2579

2580

R

Not Priced

Panes not exceeding 0,1m² in shapes other than rectangular



Not Priced

Panes exceeding 0,1m² and not exceeding 0,5m² in shapes other than rectangular



Not Priced

Panes exceeding 0,5m² and not exceeding 2m² in shapes other than rectangular



Not Priced

Panes exceeding 2m² and not exceeding 4m² in shapes other than rectangular



Not Priced

Panes exceeding ?m² and not exceeding ?m² in shapes other than rectangular



Not Priced

Sundries 2582

Polished edges to ?mm float glass

m

Not Priced

2583

Polished edges to ?mm laminated glass

m

Not Priced

2584

Butt joints to ?mm toughened glass including polished edges and silicone sealant

m

Not Priced

Butt joints to ?mm laminated glass including polished edges and silicone sealant

m

Not Priced

m

Not Priced

No

Not Priced

No

Not Priced

2585

2586

User note

2587

The following two items are normally included in the frame description or the detail measurement of the windows etc

2588

Type ? glazing gaskets

2589

Extra over for moulded corner

2590

Sandblasting including meshing

2591

Sandblasting to ? x ?mm high glass pane

2592

User note

2593

As the remainder of the glass pane is to be covered while sandblasting is done, the size of the pane is to be given

2594

Sandblasted band ? x ?mm high to ? x ?mm glass pane

No

Not Priced

2595

Sandblasted motif ? x ?mm high to ? x ?mm glass pane (Refer to drawing No ? attached to these bills of quantities)

No

Not Priced

Carried forward Bill No 22 Glazing ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-338-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2596

Set of ? sandblasted motifs each ? x ?mm high to ? x ?mm glass pane (Refer to drawing No ? attached to these bills of quantities)

2597

GLASS LOUVRE BLADES

2598

?mm Clear float glass louvre blades with polished edges

2599

?mm ? glass louvre blades with polished edges

2600

Louvre blades ?mm wide

R

Not Priced

No

Not Priced

m

Not Priced

TOPS, SHELVES, DOORS, MIRRORS, ETC ?mm Clear float glass with polished edges all round 2603

?mm Clear toughened safety glass with polished edges all round

2604

?mm Normal strength (NS) clear laminated safety glass with polished edges all round

2605

Top ? x ?mm wide, laid loose

No

Not Priced

2606

Shelf ? x ?mm wide

No

Not Priced

2607

Sliding door ? x ?mm high, with ? x ?mm sunk fingergrip

No

Not Priced

2608

?mm Silvered float glass copper backed mirrors with polished edges, fixed with double sided adhesive tape and silicone

No

Not Priced

No

Not Priced

?mm Silvered float glass copper backed mirrors with ?mm bevelled and polished edges, fixed with double sided adhesive tape and silicone 2610

Mirror ? x ?mm high ?mm Silvered float glass copper backed mirrors with polished edges, holed for and fixed with chromium plated dome capped mirror screws with rubber buffers to plugs in brickwork or concrete ?mm Silvered float glass copper backed mirrors with ?mm bevelled and polished edges, holed for and fixed with chromium plated dome capped mirror screws with rubber buffers to plugs in brickwork or concrete

2613

Mirror ? x ?mm high with ? screws

Carried forward Bill No 22 Glazing ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-339-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2614

R

Not Priced

PATENT GLAZING Type ? natural (colour?) anodised aluminium patent glazing system with head channel, sill section, intermediate vertical glazing bars fixed at top and bottom with fixing saddles bolted on and glazed with ?mm ? glass

2616

2617

Patent glazing ? x ?m high with glazing bars at ?mm centres and fixing head channel and sill section to brickwork or concrete

No

Not Priced

Patent glazing ? x ?m high with glazing bars at ?mm centres and fixing head channel and sill section to steel structure

No

Not Priced

Carried to summary Bill No 22 Glazing ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-340-

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

2618

BILL NO ?

2619

PAINTWORK

2620

User note

2621

The following four items, given as examples, have been set up to comply with the Munsell system (the extra over option) as prescribed in the Standard System of Measuring Building Work and should be inserted at the end of each type of paint where applicable

Quantity

Rate

Amount

Extra over paintwork to all areas, for paintwork in colours which have a value of 7 or less based on the Munsell system m² Extra over paintwork to gates, grilles, burglar screens, balustrades, etc, for paintwork in colours which have a value of 7 or less based on the Munsell system (both sides measured over the full flat area) m² Extra over paintwork to rails, bars, pipes, etc not exceeding 300mm girth, for paintwork in colours which have a value of 7 or less based on the Munsell system m Extra over paintwork to skirtings, rails, etc not exceeding 300mm girth for paintwork in colours which have a value of 7 or less based on the Munsell system m Note It has however become evident that application problems exist with the said "Munsell" system and until such time as the Standard System of Measuring Building Work is adjusted to overcome these problems users should determine from the relevant manufacturer which of their colour groupings differ appreciably in price and adjust descriptions accordingly 2622

SUPPLEMENTARY PREAMBLES

2623

PREPARATORY WORK TO EXISTING WORK

2624

Previously painted plastered surfaces

2625

Surfaces shall be thoroughly washed down and allowed to dry completely before any paint is applied. Blistered or peeling paint shall be completely removed and cracks shall be opened, filled with a suitable filler and finished smooth

Carried forward Bill No 23 Paintwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-341-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2626

Previously painted metal surfaces

2627

Surfaces shall be thoroughly rubbed and cleaned down. Blistered or peeling paint shall be completely removed down to bare metal

2628

Previously painted wood surfaces

2629

Surfaces shall be thoroughly cleaned down. Blistered or peeling paint shall be completely removed and cracks and crevices shall be primed, filled with suitable filler and finished smooth

2630

PAINT SPECIFICATIONS

2631

All painting shall be done in accordance with "?" specifications unless otherwise described

2632

COLOURS

2633

Unless otherwise described all paintwork shall be deemed to have a colour value in excess of 7 on the Munsell system in accordance with SANS 1091

2634

PAINTWORK ETC TO NEW WORK

2635

ON QUARRY TILE SURFACES

2636

Two coats brick dressing

2637

Floors



Not Priced

2638

Sills, thresholds, etc



Not Priced

ON INTERNAL FLOATED PLASTER SURFACES 2640

ON INTERNAL TEXTURED PLASTER SURFACES One coat alkali resistant primer and two coats PVA emulsion paint for interior use One coat alkali resistant primer and two coats superior quality acrylic emulsion paint for interior and exterior use

2643

One coat alkali resistant primer and two coats low odour premium quality highly washable and stain resistant acrylic emulsion paint for interior use

Carried forward Bill No 23 Paintwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-342-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2644

One coat alkali resistant primer and two coats premium quality ultra matt, fully washable and stain resistant acrylic emulsion paint for interior use

2645

One coat alkali resistant primer and two coats premium quality polyurethane enamel paint

2646

One coat alkali resistant primer, one coat alkyd based universal undercoat and two coats superior quality universal enamel paint

2647

One coat alkali resistant primer, one coat superior quality acrylic emulsion paint for interior and exterior use and one coat pure acrylic smooth ripple paint applied with a stipple roller

2648

Walls



Not Priced

2649

Walls in patterned multi-colours



Not Priced

2650

Ceilings and beams



Not Priced

2651

Ceilings and beams in patterned multi colours



Not Priced

2652

Mouldings and bands in colours differing from surrounding work



Not Priced

m

Not Priced



Not Priced

2653

Mouldings and bands not exceeding 300mm wide or girth in colours differing from surrounding work

2654

ON EXTERNAL FLOATED PLASTER SURFACES

2655

ON EXTERNAL TEXTURED PLASTER SURFACES

2656

One coat alkali resistant primer and two coats superior quality acrylic emulsion paint for interior and exterior use

2657

One coat alkali resistant primer and two coats premium quality polyurethane enamel paint

2658

One coat alkali resistant primer and two coats extremely durable UV-resistant washable pure acrylic emulsion sheen paint with teflon

2659

One coat alkali resistant primer and two coats extremely durable UV-resistant waterbased mica reinforced fine textured acrylic paint

2660

Walls

Carried forward Bill No 23 Paintwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-343-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2661

Walls in patterned multi-colours



Not Priced

2662

Ceilings and beams



Not Priced

2663

Ceilings and beams in patterned multi-colours



Not Priced

2664

Mouldings and bands in colours differing from surrounding work



Not Priced

m

Not Priced

2665

Mouldings and bands not exceeding 300mm wide or girth in colours differing from surrounding work

2666

ON INTERNAL GYPSUM PLASTER SURFACES

2667

One coat primer and two coats superior quality acrylic emulsion paint for interior and exterior use

2668

One coat primer and two coats low odour premium quality highly washable and stain resistant acrylic emulsion paint for interior use

2669

One coat primer and two coats premium quality ultra matt, fully washable and stain resistant acrylic emulsion paint for interior use

2670

One coat primer and two coats premium quality polyurethane enamel paint

2671

One coat primer and one coat alkyd based universal undercoat and two coats superior quality universal enamel paint

2672

Walls



Not Priced

2673

Walls in patterned multi-colours



Not Priced

2674

Ceilings and beams



Not Priced

2675

Ceilings and beams in patterned multi-colours



Not Priced

2676

Mouldings and bands in colours differing from surrounding work



Not Priced

m

Not Priced

2677

2678

Mouldings and bands not exceeding 300mm wide or girth in colours differing from surrounding work

ON BAGGED BRICKWORK OR CONCRETE SURFACES

Carried forward Bill No 23 Paintwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-344-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2679

One coat alkali resistant primer and two coats PVA emulsion paint for interior use

2680

One coat alkali resistant primer and two coats superior quality acrylic emulsion paint for interior and exterior use

2681

One coat alkali resistant primer and two coats low odour premium quality highly washable and stain resistant acrylic emulsion paint for interior and exterior use

2682

Walls



Not Priced

2683

Ceilings and beams



Not Priced

2684

ON FAIR FACED BRICKWORK

2685

One coat alkali resistant primer and two coats PVA emulsion paint for interior use

2686

One coat alkali resistant primer and two coats superior quality acrylic emulsion paint for interior and exterior use

2687

One coat alkali resistant primer and two coats low odour premium quality highly washable and stain resistant acrylic emulsion paint for interior and exterior use

2688

Walls



Not Priced

2689

ON SMOOTH CONCRETE SURFACES

2690

ON ROUGH CONCRETE SURFACES

2691

One coat alkali resistant primer and two coats PVA emulsion paint for interior use, including stopping blow holes

2692

One coat primer and two coats superior quality acrylic emulsion paint for interior and exterior use, including stopping blow holes

2693

Walls and columns



Not Priced

2694

Ceilings and beams



Not Priced

2695

Coffered ceilings (total girth measured)



Not Priced

2696

ON PLASTERBOARD SURFACES

Carried forward Bill No 23 Paintwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-345-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2697

One coat alkali resistant primer and two coats PVA emulsion paint for interior use

2698

One coat primer and two coats superior quality acrylic emulsion paint for interior and exterior use

2699

One coat alkali resistant primer and two coats low odour premium quality highly washable and stain resistant acrylic emulsion paint for interior use

2700

One coat alkali resistant primer and two coats premium quality ultra matt, fully washable and stain resistant acrylic emulsion paint for interior use

2701

Partitions



Not Priced

2702

Ceilings and cornices



Not Priced

2703

Ceilings and cornices, including priming metal cover strips and nailheads



Not Priced

2704

ON FIBRE-CEMENT BOARD SURFACES

2705

One coat alkali resistant primer and two coats superior quality acrylic emulsion paint for interior and exterior use

2706

Two coats extremely durable UV-resistant, washable pure acrylic emulsion sheen paint

2707

Ceilings and cornices, including priming metal cover strips and nailheads



Not Priced

Fascias and barge boards, including priming metal jointing strips



Not Priced

2709

Flue pipes, including priming metal holderbats



Not Priced

2710

Fascias and barge boards not exceeding 300mm girth, including priming metal jointing strips

m

Not Priced

Flue pipes not exceeding 300mm girth, including priming metal holderbats

m

Not Priced

2708

2711

2712

ON METAL SURFACES

2713

One coat alkyd based zinc phosphate primer and two coats premium quality polyurethane enamel paint, on steel

Carried forward Bill No 23 Paintwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-346-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2714

One coat alkyd based zinc phosphate primer, one coat alkyd based universal undercoat and two coats superior quality universal enamel paint, on steel

2715

One coat water based primer and two coats premium quality polyurethane enamel paint, on galvanised steel

2716

One coat water based primer, one coat alkyd based universal undercoat and two coats superior quality universal enamel paint, on galvanised steel

2717

Doors



Not Priced

2718

Door frames



Not Priced

2719

Recordroom and strongroom doors and frames



Not Priced

2720

Roller shutter boxes



Not Priced

2721

Windows



Not Priced

2722

Windows with burglar bars



Not Priced

2723

Columns and beams



Not Priced

2724

Members of lattice columns and beams



Not Priced

2725

Members of roof trusses



Not Priced

2726

Members of lattice roof trusses



Not Priced

2727

Gates, grilles, burglar screens, balustrades, etc (both sides measured over the full flat area)



Not Priced

2728

Rails, bars, pipes, etc



Not Priced

2729

Eaves gutters



Not Priced

2730

Rainwater downpipes



Not Priced

2731

Rails, bars, pipes, etc not exceeding 300mm girth

m

Not Priced

2732

Eaves gutters not exceeding 300mm girth

m

Not Priced

2733

Rainwater downpipes not exceeding 300mm girth

m

Not Priced

2734

Three coats modified acrylic lacquer paint, on copper

2735

Rails, bars, pipes, etc not exceeding 300mm girth

m

Not Priced

Carried forward Bill No 23 Paintwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-347-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2736

One coat modified alkyd aluminium primer and two coats extremely durable UV-resistant washable pure acrylic paint, on cast iron

2737

Rails, bars, pipes, etc

2738

Rails, bars, pipes, etc not exceeding 300mm girth

2739

One coat water based galvanised iron primer and two coats UV-resistant water based alkyd roof paint, on galvanised steel

2740 2741

R

Not Priced



Not Priced

m

Not Priced

Corrugated roofs (measured on flat)



Not Priced

IBR profile troughed roofs (measured on flat)



Not Priced

m

Not Priced

ON WOOD SURFACES 2743

Two coats oil wood primer

2744

Backs of frames, linings, etc not exceeding 300mm wide One coat primer and two coats premium quality polyurethane enamel paint One coat primer, one coat alkyd based universal undercoat and two coats superior quality universal enamel paint

2747

Three coats exterior quality penetrating wood preservative

2748

Three coats superior quality clear gloss varnish

2749

Three coats superior quality clear matt varnish

2750

Three coats superior quality polyurethane suede varnish

2751

Doors



Not Priced

2752

Moulded panel doors



Not Priced

2753

Windows, sash doors and fanlights



Not Priced

2754

Louvered windows and doors



Not Priced

2755

Door frames etc



Not Priced

2756

Roof timbers at eaves and verges



Not Priced

2757

Boarded panelling



Not Priced

Carried forward Bill No 23 Paintwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-348-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2758

Boarded ceilings



Not Priced

2759

Open slatted shelves, seats, etc of ? x ?mm slats at ?mm centres (both sides measured over the full flat area)



Not Priced

Open slatted panelling of ? x ?mm slats at ?mm centres with fabric covering at back (one side measured over the full flat area)



Not Priced

m

Not Priced

2760

2761

Skirtings, rails, etc not exceeding 300mm girth

2762

PAINTWORK, ETC TO PREVIOUSLY PAINTED WORK

2763

ON INTERNAL FLOATED PLASTER SURFACES

2764

One coat superior quality acrylic emulsion paint for interior and exterior use, on work in sound condition

2765

One coat low odour premium quality highly washable and stain resistant acrylic emulsion paint, on work in sound condition

2766

One coat premium quality polyurethane enamel paint, on work in sound condition

2767

One coat alkyd based universal undercoat and one coat superior quality universal enamel paint, on work in sound condition

2768

One coat extremely durable UV-resistant washable pure acrylic emulsion sheen paint, on work in sound condition

2769

Walls



Not Priced

2770

Ceilings and beams



Not Priced

2771

ON EXTERNAL FLOATED PLASTER SURFACES

2772

Two coats superior quality acrylic emulsion paint for interior use, on work in poor condition

2773

Two coats extremely durable UV-resistant washable pure acrylic emulsion sheen paint with teflon, on work in poor condition

2774

Walls



Not Priced

2775

Ceilings and beams



Not Priced

Carried forward Bill No 23 Paintwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-349-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2776

Extra over paintwork to all areas for paintwork in colours which have a value of 7 or less on the Munsell system

R

Not Priced



Not Priced

2777

ON PLASTERBOARD SURFACES

2778

One coat superior quality acrylic emulsion paint for interior and exterior use, on work in sound condition

2779

Two coats superior quality acrylic emulsion paint for interior and exterior use, on work in poor condition

2780

One coat low odour premium quality highly washable and stain resistant acrylic emulsion paint, on work in sound condition

2781

Two coats low odour premium quality highly washable and stain resistant acrylic emulsion paint, on work in poor condition

2782

Partitions



Not Priced

2783

Ceilings and cornices



Not Priced

2784

Extra over paintwork to all areas for paintwork in colours which have a value of 7 or less on the Munsell system



Not Priced



Not Priced

m

Not Priced



Not Priced

2785

ON FIBRE-CEMENT BOARD SURFACES

2786

One coat extremely durable UV-resistant washable pure acrylic paint, on work in sound condition

2787

Two coats extremely durable UV-resistant washable pure acrylic paint, on work in poor condition

2788

Fascias and barge boards

2789

Fascias and barge boards not exceeding 300mm girth

2790

ON METAL SURFACES

2791

One coat alkyd based universal undercoat and one coat superior quality universal enamel paint, on work in sound condition

2792

Spot priming bare metal surfaces, one coat alkyd based universal undercoat and two coats superior quality universal enamel paint, on work in poor condition

2793

Door frames

Carried forward Bill No 23 Paintwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-350-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2794

Recordroom and strongroom doors and frames



Not Priced

2795

Roller shutter boxes



Not Priced

2796

Windows



Not Priced

2797

Windows with burglar bars



Not Priced

2798

Columns and beams



Not Priced

2799

Rails, bars, pipes, etc not exceeding 300mm girth

m

Not Priced

2800

ON WOOD SURFACES

2801

One coat alkyd based universal undercoat and one coat superior quality universal enamel paint, on work in sound condition

2802

Spot priming bare wood surfaces, one coat alkyd based universal undercoat and two coats superior quality universal enamel paint, on work in poor condition

2803

Doors



Not Priced

2804

Door frames etc



Not Priced

2805

Roof timbers at eaves and verges



Not Priced

2806

Skirtings, rails, etc not exceeding 300mm girth

m

Not Priced

2807

One coat exterior quality penetrating wood preservative, on work in sound condition

2808

Two coats exterior quality penetrating wood preservative, on work in poor condition

2809

One coat superior quality clear gloss varnish, on work in sound condition

2810

Two coats superior quality clear gloss varnish, on work in poor condition

2811

One coat superior quality clear matt varnish, on work in sound condition

2812

Two coats superior quality clear matt varnish, on work in poor condition

2813

Doors



Not Priced

Carried forward Bill No 23 Paintwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-351-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

2814

Door frames etc



Not Priced

2815

Roof timbers at eaves and verges



Not Priced

2816

Skirtings, rails, etc not exceeding 300mm girth

m

Not Priced

2817

SIGNWRITING

m

Not Priced

Primer and two coats suitable paint on plaster, metal, wood or glass 2819

Identification bands 100mm wide at ?m centres on pipes not exceeding 300mm girth

2820

Directional arrow not exceeding 150mm long on pipe

No

Not Priced

2821

Sans serif numeral or letter ?mm high

No

Not Priced

2822

Punctuation mark to preceding item

No

Not Priced

2823

Two coats TP24 road marking paint on tarmacadam

2824

Etching primer and two coats TP24 road marking paint on concrete

2825

Line ?mm wide

m

Not Priced

2826

Numeral or letter ?mm high

No

Not Priced

2827

Traffic arrow ? x ?mm wide extreme

No

Not Priced

2828

Paraplegic parking motif ? x ?mm extreme

No

Not Priced

2829

SPECIAL FINISHES

2830

The following paintwork is to be executed in accordance with "?" specifications

2831

FINISH ON NEW WORK

2832

ON EXTERNAL FLOATED PLASTER SURFACES

2833

One coat acrylic masonry primer, two coats pre-pigmented texturised pure acrylic coating and one acrylic glaze coat, applied by specialists

2834

Walls



Not Priced

Carried forward Bill No 23 Paintwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-352-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 2835

2836

Mouldings and bands in colours differing from surrounding work Mouldings and bands not exceeding 300mm wide or girth in colours differing from surrounding work

Carried to summary Bill No 23 Paintwork ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-353-

R

Not Priced



Not Priced

m

Not Priced

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

Quantity

Rate

Amount

3033

BILL NO ?

3034

PAPERHANGING

3035

PAPERHANGING TO NEW WORK

3036

"?" paper backed vinyl wallpaper, including one coat preparatory emulsion paint

3037

Paper backed vinyl wallpaper (PC R ? per roll ?mm wide x ?m long), including one coat preparatory emulsion paint

3038

On one coat plastered walls and columns including narrow widths



Not Priced

On two coat plastered walls and columns including narrow widths



Not Priced

3040

On drywall partitions including narrow widths



Not Priced

3041

"?" borders and motifs

3042

?mm Wide borders type ?

m

Not Priced

3043

?mm Wide borders (PC R ? per roll of ?m)

m

Not Priced

3044

? x ?mm Extreme motif type ?

No

Not Priced

3045

? x ?mm Extreme motif (PC R ? each)

No

Not Priced

3046

PAPERHANGING TO EXISTING WORK

3047

Preparatory work to previously painted surfaces

3048

Surfaces shall be thoroughly washed down and allowed to dry completely before paperhanging is commenced. Blistered and peeling paint shall be completely removed and cracks shall be opened, filled with a suitable filler and finished smooth. All surfaces shall be painted with a single coat of interior quality PVA emulsion paint

3049

"?" paper backed vinyl wallpaper on previously painted surfaces, including one coat preparatory emulsion paint

3050

Paper backed vinyl wallpaper (PC R ? per roll ?mm wide x ?m long), on previously painted surfaces, including one coat preparatory emulsion paint

3051

On walls and columns including narrow widths



Not Priced

3039

Carried forward Bill No 24 Paperhanging ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-354-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 3052

On drywall partitions including narrow widths

3053

SUNDRIES

3054

Taking off and removing existing wallpaper and preparing for new finish

3055 3056

R

Not Priced



Not Priced

Wallpaper on plastered walls and columns



Not Priced

Wallpaper on drywall partitions



Not Priced

Carried to summary Bill No 24 Paperhanging ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-355-

R

Not Priced

24/02/2006 10:50:51 AM

Item No

Unit

3057

BILL NO ?

3058

EXTERNAL WORK

3059

LANDSCAPING

3060

User note

3061

Selected examples of typical items with trade names are provided to show possible ways of describing such items. Users must adapt these examples to suit their particular circumstances

3062

SUPPLEMENTARY PREAMBLES

3063

Landscaping specification

3064

Refer to the landscape architect's specification annexed to these bills of quantities which is supplementary to and shall take precedence over the "Model Preambles for Trades"

3065

Excavate in earth and dispose on site

3066

To remove humps, form shallow ditches, etc

3067

Ground preparation

3068

Cultivation and preparation of areas to be planted

3069

Topsoil obtained from prescribed stock piles on site, including spreading and levelling

3070

Topsoil supplied by the contractor, including spreading and levelling

3071

Topsoil supplied by the contractor (3 parts top soil, 1 part compost and 1 part milled pine bark), including spreading and levelling

3072

Quantity

Rate

Amount



Not Priced



Not Priced

In plant beds, grassed areas and holes for trees, shrubs, etc



Not Priced

3073

In plant boxes, pots, etc



Not Priced

3074

Compost, lime and fertilizer

3075

Compost in plant beds, holes for trees, shrubs, etc



Not Priced

3076

Compost in plant boxes, pots, etc



Not Priced

Carried forward Bill No 25 External Work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-356-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

3077

Agricultural lime for trees, shrubs, ground covers, etc

kg

Not Priced

3078

Super phosphate granular commercial fertilizer for trees, shrubs, ground covers, etc

kg

Not Priced



Not Priced

3079

Mulch

3080

25mm Thick mulch layer in plant beds between plants

3081

Shrubs, bulbs and plants

3082

Abelia postrata (4l container)

No

Not Priced

3083

Agapanthus spp "Blue" (2l container)

No

Not Priced

3084

Bauhinia galpinii (4l container)

No

Not Priced

3085

Trees

3086

Acer palmatum 600mm high

No

Not Priced

3087

Acacia melanoxylon 600mm high

No

Not Priced

3088

Grassing, ground covers, etc

3089

"Kikuyu" roots in rows at 250mm centres



Not Priced

3090

"Kikuyu" sods approximately 500 x 500 x 50mm thick



Not Priced

3091

"Kikuyu" rolls 50mm thick



Not Priced

3092

Asparugus densiflorus "Sprengeri" (0,5l container) (8/m²)



Not Priced

3093

Plumbago auriculata (0,5l container) (8/m²)



Not Priced

3094

Pruning of existing trees and shrubs

3095

Pruning of existing 4m high acacia karroo tree

No

Not Priced

3096

Pruning of existing 4m high celtis africana tree

No

Not Priced

3097

Pebble covering

3098

Covering of river stone pebbles varying in size from 20mm to 50mm diameter



Not Priced

Carried forward Bill No 25 External Work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-357-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

3099

Rockery boulders

3100

Rockery boulder approximately 400mm diameter obtained from stock piles on site

No

Not Priced

Rockery boulder approximately 400mm diameter supplied by the contractor

No

Not Priced

Rectangular rockery boulder approximately 0,1m3 obtained from stock piles on site

No

Not Priced

No

Not Priced

3101

3102

3103

Rectangular rockery boulder approximately 0,1m3 supplied by the contractor

3104

Maintenance

3105

Allow for maintaining landscaping for a period of ?months, including watering, weeding, cutting, replacing dead plants, etc

3106

IRRIGATION SYSTEM

3107

High density polyethylene class 10 type IV piping complying with SANS 533-1 with "?" compression couplings

3108

20mm Pipes laid in and including trenches

3109

Extra over polyethylene type IV pipes for "?" compression fittings

3110

20mm Fittings

3111

Extra over polyethylene type IV pipes for composite fittings comprising galvanised and "?" compression components

3112

Item

Not Priced

m

Not Priced

No

Not Priced

20mm Tee assembly type ?

No

Not Priced

3113

20mm Brass ball valve in and including suitable valve box

No

Not Priced

3114

20mm Brass ball valve assembly type ? with 20mm inlet and 20mm outlet

No

Not Priced

No

Not Priced

3115

Microsprays

3116

Type ? mist microspray

Carried forward Bill No 25 External Work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-358-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

3117

Mist sprayers on riser pipes

3118

Type ? mist sprayer on 6mm pipe 300mm high

3119

Pop-up sprayers

3120

Type ? pop-up mist sprayer on 20mm pipe

3121

Pop-up sprinklers

3122

Type ? rotary pop-up sprinkler on 20mm pipe

3123

Testing

3124

Testing irrigation system

3125

BENCHES, TABLES, ETC

3126

"Wilson's Townscape" garden furniture with grey exposed aggregate finish to precast concrete components, including excavation, backfilling and unreinforced concrete footings where applicable

3127

Bench type "Half penny"

No

Not Priced

3128

Bench type "Penny"

No

Not Priced

3129

Bench type "Hounslow"

No

Not Priced

3130

Bench type "Maidstone"

No

Not Priced

3131

Bench type "Belgrave"

No

Not Priced

3132

Bench type "Tree pit bench"

No

Not Priced

3133

Bench and table combination type "Rest set"

No

Not Priced

3134

RETAINING STRUCTURES

3135

Open face excavation in earth

3136

To embankment behind retaining blocks including trimming to slope



Not Priced

No

Not Priced

No

Not Priced

No

Not Priced

Item

Not Priced

3137

Excavation in earth not exceeding 2m deep

3138

Trenches



Not Priced

3139

Holes



Not Priced

Carried forward Bill No 25 External Work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-359-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 3140

Risk of collapse of excavations

3141

Sides of trench and hole excavations not exceeding 1,5m deep

R

Not Priced



Not Priced



Not Priced



Not Priced

m

Not Priced

3142

Earth filling obtained from the excavations and/or prescribed stock piles on site compacted to ?% Mod AASHTO density

3143

To form embankments for retaining structures

3144

?MPa/?mm unreinforced concrete

3145

Strip footings

3146

Rough formwork to sides

3147

Edges not exceeding 300mm high

3148

INTERLOCKING PLANTER BLOCKS

3149

User note

3150

Planter blocks are available in various sizes and in "standard" and "heavy duty" in each size. Types are dependent on wall and soil conditions

3151

"?" precast concrete interlocking planter blocks finished smooth on exposed surfaces

3152

Retaining structures with stepped face and curves as required to suit slopes, of ? x ? x ?mm high type "?" interlocking planter blocks laid with horizontal bed joints to ? degree slope, including average ?mm thick compacted earth filling behind the blocks and filling blocks with garden soil lightly tamped as the work proceeds



Not Priced

Retaining structures with raking face and curves as required to suit slopes, of ? x ? x ?mm high type "?" interlocking planter blocks laid with sloping bed joints, including average ?mm thick compacted earth filling behind blocks and filling blocks with garden soil lightly tamped as the work proceeds



Not Priced

3153

3154

ROADWORK, PARKING AREAS AND PAVING

3155

SUPPLEMENTARY PREAMBLES

Carried forward Bill No 25 External Work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-360-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 3156

Testing of material and filling

3157

Descriptions of earth filling, compaction, etc shall be deemed to include for all necessary testing required in accordance with the SABS 1200 series

3158

Precast concrete block road surfacing

3159

Paving shall be laid in accordance with SABS 1200 MJ, SA NS 1058 and the Concrete Masonry Association's specifications

3160

Paving shall be laid to herringbone (?) pattern on 20mm thick (thickness after final compaction) clean river sand (preparation of ground or filling elsewhere)

3161

Clean sand shall be swept into joints between roadstones at completion

3162

Site clearance

3163

Digging up and removing rubbish, debris, vegetation, hedges, shrubs, bush, etc and trees not exceeding 200mm girth

3164

Open face excavation in earth over sloping site

3165

Open face excavation to form platforms under parking areas etc and depositing excavated material over site, including haulage not exceeding ?m from perimeter of excavations

R

Not Priced



Not Priced



Not Priced

3166

Excavation in earth not exceeding 2m deep

3167

Over site between buildings, retaining walls, etc to reduce levels and dispose in prescribed stock piles on site



Not Priced

?mm Deep over site between buildings, retaining walls, etc to remove top soil and dispose in prescribed stock piles on site



Not Priced

3168

3169

Extra over bulk excavation in earth for excavation in

3170

Soft rock



Not Priced

3171

Hard rock



Not Priced

Carried forward Bill No 25 External Work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-361-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward

R

Not Priced

3172

Extra over bulk excavation in earth for breaking up and removing

3173

Brickwork



Not Priced

3174

Unreinforced concrete



Not Priced

3175

Reinforced concrete



Not Priced

3176

Extra over all excavations for carting away

3177

Surplus material from excavations and/or stock piles on site to a dumping site to be located by the contractor



Not Priced

3178

Keeping excavations free of water

3179

Keeping excavations free of water other than subterranean water

Item

Not Priced

3180

Selected earth filling obtained from stock piles on site, including haulage approximately ?m from perimeter of stock piles (maximum aggregate size of ?mm)

3181

Under road islands etc compacted to ?% Mod AASHTO density



Not Priced

Sub-base course under parking areas etc compacted to ?% Mod AASHTO density



Not Priced

Base course under parking areas etc stabilised with ?% Portland blast furnace cement (by volume) and compacted to ?% Mod AASHTO density



Not Priced

3182

3183

3184

Earth filling supplied by the contractor under parking areas, roadways, etc

3185

Filling of G9 material in accordance with SABS 1200 DM, compacted to ?% Mod AASHTO density



Not Priced

Filling of G7 material in accordance with SABS 1200 DM, compacted to ?% Mod AASHTO density



Not Priced

Sub-base course of G5 material in accordance with SABS 1200 DM, compacted to ?% Mod AASHTO density



Not Priced

Base course of G5 material in accordance with SABS 1200 ME, stabilised to attain UCS>1,0 MPa after seven days and compacted to ?% Mod AASHTO density



Not Priced

3186

3187

3188

Carried forward Bill No 25 External Work ASAQS MODEL BILLS OF QUANTITIES - FEB 2006

-362-

R

Not Priced

24/02/2006 10:50:51 AM

Brought forward 3189

Base course of crushed stone in accordance with SABS 1200 ME, compacted to ?% of apparent density (PI
View more...

Comments

Copyright ©2017 KUPDF Inc.
SUPPORT KUPDF