Meter HXE34K DataSheet

February 27, 2018 | Author: Antonio Jimenez | Category: Alternating Current, Voltage, Electricity, Electrostatic Discharge, Electromagnetic Compatibility
Share Embed Donate


Short Description

Medidor HEXING...

Description

HXE34K HXE34K Three Phase Four Wire Conventional Meter

HXE34K is a direct connection meter applied in two- or three-phase network for measuring active and reactive energy. It features compact design, multi TOU functions and multi communication protocol.

n Highlights Ø Ø Ø

Optical communication(IEC62056-21) DLMS/COSEM protocol capable(optional) RF communication(optional)

n Main Functionalities Ø Ø

Ø Ø

Ø

Active/reactive energy and tariff measurement Demand l Demand Interval configurable l Block or slide mode configurable l Active and reactive MD with time stamp l Active and reactive MD in tariff with time stamp Instantaneous values measurement Tariff l Up to 4 tariffs l Up to 10 divisions per day, weekend configurable l Up to 8 daily tables l Up to 12 seasons, working day and weekend tariff scheme configurable per season l Week table l Up to 120 holidays configurable individually per year LCD Display l 12-Month Billing Data l Large display with 8 digits, easy for reading l LCD display with OBIS code

Display content and circle configurable l LCD Backlights configurable to increase readability in low light conditions(optional) 2 LED for metering calibration Bypass detection for tampering-proof(optional) Event Record l External magnetic detection and record (optional) l Meter Cover open detection and record (optional) l Terminal Cover open detection and record (optional) DLMS/COSEM protocol capable(optional) RS485 or RS232 optional alternative(optional) Four quadrant reactive energy in tariffs(optional) Load profile (optional) l Channel quantity customized before leaving the factory; up to 14channels l Depth of each channel customized before leaving the factory l Flexible record modes Auxiliary terminals for energy pulse output l

Ø Ø Ø

Ø Ø Ø Ø

Ø

n Specifications Description

Value

Accuracy

CT: Class 0.5S or Class 1 (IEC), Class A or Class B (MID),Class 2(Reactive)

Voltage Reference voltage

3x220/380V-3x240/415V

Operating voltage range

80%-120%Un

Current Basic current

1.5A,5A(CT) 5A,10A(DC)

Maximum current

6A(CT),40A, 60A, 80A, 100A(DC)

Starting current

< 0.4%Ib(0.2% CT)

Frequency

50Hz or 60Hz

Temperature Operation range

-25℃~55℃

Limit range for storage and transport

-40℃~70℃

Humidity

Up to 95% non-condensing

Power Consumption Power consumption in voltage circuit (active)

≤2 W

Power consumption in voltage circuit (apparent)

≤10 VA

Power consumption in current circuit

≤1 VA

Insulation Strength AC voltage test

4kV during 1min

Impulse voltage test

1.2/50µs mains connections 6kV

EMC Electrostatic discharges(Contact discharges)

8kV

Electrostatic discharges(Air discharges)

15kV

Surge immunity test

4kV

Fast transient burst test

4kV

Electromagnetic RF fields (80MHz to 2000MHz)

10V/m(with current), 30V/m(without current)

Connection Terminals Housing

9mm x 9mm

Protection degree

IP54(with long terminal cover)

Meter cover

Opaque PC+ glass fiber with a transparent window

Meter base

Opaque PC+ glass fiber

Terminal cover

Opaque PC + glass fiber

Display Digit size

10.0mm x 5.0mm

Number of digits

8

Communication Interface Optical communication

IEC62056-21 or DLMS

RS485/RS232

IEC62056-21 or DLMS

RF

IEC62056-21,