HXE34K HXE34K Three Phase Four Wire Conventional Meter
HXE34K is a direct connection meter applied in two- or three-phase network for measuring active and reactive energy. It features compact design, multi TOU functions and multi communication protocol.
Active/reactive energy and tariff measurement Demand l Demand Interval configurable l Block or slide mode configurable l Active and reactive MD with time stamp l Active and reactive MD in tariff with time stamp Instantaneous values measurement Tariff l Up to 4 tariffs l Up to 10 divisions per day, weekend configurable l Up to 8 daily tables l Up to 12 seasons, working day and weekend tariff scheme configurable per season l Week table l Up to 120 holidays configurable individually per year LCD Display l 12-Month Billing Data l Large display with 8 digits, easy for reading l LCD display with OBIS code
Display content and circle configurable l LCD Backlights configurable to increase readability in low light conditions(optional) 2 LED for metering calibration Bypass detection for tampering-proof(optional) Event Record l External magnetic detection and record (optional) l Meter Cover open detection and record (optional) l Terminal Cover open detection and record (optional) DLMS/COSEM protocol capable(optional) RS485 or RS232 optional alternative(optional) Four quadrant reactive energy in tariffs(optional) Load profile (optional) l Channel quantity customized before leaving the factory; up to 14channels l Depth of each channel customized before leaving the factory l Flexible record modes Auxiliary terminals for energy pulse output l
Ø Ø Ø
Ø Ø Ø Ø
Ø
n Specifications Description
Value
Accuracy
CT: Class 0.5S or Class 1 (IEC), Class A or Class B (MID),Class 2(Reactive)
Voltage Reference voltage
3x220/380V-3x240/415V
Operating voltage range
80%-120%Un
Current Basic current
1.5A,5A(CT) 5A,10A(DC)
Maximum current
6A(CT),40A, 60A, 80A, 100A(DC)
Starting current
< 0.4%Ib(0.2% CT)
Frequency
50Hz or 60Hz
Temperature Operation range
-25℃~55℃
Limit range for storage and transport
-40℃~70℃
Humidity
Up to 95% non-condensing
Power Consumption Power consumption in voltage circuit (active)