MCS - LCB II List of Parameters
Short Description
Download MCS - LCB II List of Parameters...
Description
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 1 / 25
Date
: 27-Jun-1995
MCS - LCB_II List of Installation Parameters
Authorization Date D1: 27-Jun-1995 Running on PCB:
GCA 21240 D1 - D3 GDA 21240 D1 - D3
Software Version:
GAA 30082 BAC
Document Revision: 24 - May - 93 03 - Dec - 93 29 - Apr - 94 02 - Jun - 94 16 - Jun - 94 17 - Jan - 95
- Original Document - OTIS 2000 features add. - Triplex parameter added - Secure Access revised - BSM mode added - MCS220M, LSVF-W, ELD, REM III added 06 - Jun - 95 GAA 30082 BAB A. Gerwing - not distributed 27 - Jun - 95 GAA 30082 BAC A.Gerwing - CPC-TYP, N+2, ELD-MSG, ELD-DOOR GAA 30082 AAA GAA 30082 AAB GAA 30082 AAC GAA 30082 AAD GAA 30082 AAE GAA 30082 BAA
J. Schulte A.Gerwing M. Hnida M. Hnida J. Schulte J. Schulte
Copyright 1995, OTIS GmbH Berlin No part of this document may be copied or reproduced in any form or by any means without the prior written consent of OTIS GmbH.
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 2 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
System: No.
Symbol
Default
0
TOP
2
Purpose and Range Top position: 1 (1) 31
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 1
LOBBY
0
Lobby position: 0 (1) 31
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 2
BOTTOM
0
Bottom position: 0 (1) 30
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 3
CFT-P
255
Cafeteria Position: 0 (1) 31 > 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 4
OPERAT
1
Operation FCL/DCL/SAPB: 0 FCL 1 DCL 2 SAPB
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 5
EN-BSM
0
Enable BSM mode (for DCL: both Up- and Down Hall Calls at lobby): 0 Disabled 1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 6
CONFIG
0
General configuration: 0 ETO 1 NAO
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 7
PI
4
Type of serial Position Indicator: 0 7/16 Segment 1 Multil. 2 Australian Dot Matrix 3 Australian Dot Matrix with CUDL/CDDL 4 OTIS 2000: LCD and ELD
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 8
ELD-fOPG
20
front door movement time: opening 0 (0.1) 10.0 s 0 = automatic (not yet implem.)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 9
ELD-fCLG
20
front door movement time: closing 0 (0.1) 10.0 s 0 = automatic (not yet implem.)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 10
ELD-rOPG
20
rear door movement time: opening 0 (0.1) 10.0 s 0 = automatic (not yet implem.)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Symbol
Default
11
ELD-rCLG
20
: 3 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
System (continued): No.
Page
Purpose and Range rear door movement time: closing 0 (0.1) 10.0 s 0 = automatic (not yet implem.)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 12
ELD-LNG
5
set Language for ELD: 0 (1) 19 0 SwiGer, 1 SwiFRA, 5 UK, 6 Spain, 10 Sweden, 11 Luxem, 15 Denmar, 16 SthAfr,
2 7 12 17
SwiIta, Nether, Belg, Finlnd,
3 8 13 18
Fra, Ger, Por, Ara,
4 9 14 19
Italy, Aus, Egy, Kuw
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 13
ELD-Sym1
0
Enable Non-Smoking symbol: 0 Disabled 1 symbol is displayed
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq R) 14 ELD-DOOR 0 select type of door display: 0: 1 COP for 1 door or R) 2 COPs for 2 doors R) 1: only 1 COP for 2 doors R) qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq R) 15 ELD-MSG 0 enables customer messages: R) 0: no customer messages are displayed by ELD R) 1: customer messages are enabled (use SETUP-ELD to define the texts) R) qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 16
EN-SFR
0
Enable SFR (signal flicker): 0 Disabled 1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 17
LR-T
20
FAN (LR) time: 0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 18
EN-HLC
0
Enable Hall Lanterns on car calls: 0 Disabled 1 HLC 2 HL also during closing 3 HLC and during door closing
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 19
HDL-TY
0
Hall Direction Lantern Type of OTIS 2000 Hall Button Box: 0 Direction Indicator 1 Hall Lantern
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 20
HL-SET
0
Hall Lantern/Gong Setup: 0 HL/G at same pins 1 HL/G at 1 2/3 4 2 HL/G at 3 4/1 2
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 4 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
System (continued): No.
Symbol
Default
21
CR-DIR
0
Purpose and Range Correction Fast Run Preferred Direction: 0 Down 1 Up
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 22
EN-RR
0
Enable Reduced Run (RR): 0 Disabled 1 Enabled (short or medium run)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 23
DZCNT
1
Use DZ for SL counting (for Short Run): 0 Disabled 1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 24
EN-DZI
0
Enable DZI (Door Zone Indicator): 0 Disabled 1 Enabled (only if no Door ByPass)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 25
R) R)
ERO-TYP
0
Define ERO type 0 without limit 1 with limit at terminal landings (same as TCI-limit) 2 ERO-input disabled (for LCB_II version D2)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 26
C-CHK
0
Enable C-Circuit Check: 0 Disabled 1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 27
R) R)
MD/AES
0
select use of MD input (P7:9, only MCS220M): 0 not connected 1 MD: DCS-input for Multi Door (manual plus autom. landing doors) 2 AES: ES-input if RSS or ESB is used
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
28 CPC-TYP 0 select use of CPC outputs: R) 0 car position contact R) 1 ’car here’ light R) 2 french SSM R) qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq R) 29 N+2 WIRE 0 enable 3 wire buttons: R) 0 normal car and hall buttons 1 3 wire car buttons R) 1 3 wire hall buttons R) 1 3 wire car and hall buttons R) qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 5 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
OCSS: No.
Symbol
Default
0
CPR-T
20
Purpose and Range Car Call Preference: 0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 1
ARD-P
255
Automatic Return Device Position: 0 (1) 31 > 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 2
ARD-T
0
Set Delay for ARD (Automayic Return Device) mode: 0 (10) 2550 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 3
L-PARK
0
Lobby Park Option: 0 Disabled 1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 4
CTL/PKS
0
Select CTL or PKS switch: 0 CTL switch is connected 1 PKS switch is connected
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 5
PKS-P
255
Parking Service Position: 0 (1) 31 > 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 6
PKS-TY
0
Parking Shutoff Type: 0 ETO 1 NAO 2 ETO with door open after shutdown
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 7
PKS-T
0
Parking Shutoff Time: 0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 8
PKS-DO
0
PKS default door: 0 Both doors will open at PKS-P 1 Only front door opens 2 Only rear door opens
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 9
EN-SHB
0
Enable Separate Hall Buttons: 0 Normal HB-operation 1 Rear HB as Separate Riser
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 10
DCP-T
50
Time until DCP-mode (delayed car protection): 25 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 11
CTL-DO
0
CTL default door (car to any landing): 0 Both doors will open at CTL-P 1 Only front door opens 2 Only rear door opens
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 6 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
OCSS (continued): No.
Symbol
Default
12
CTL-P
255
Purpose and Range CTL (Car To Any Landing) position: 0 (1) 31 > 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 13
ANS
0
ANS (anti nuisance service): 0 Disabled >0 Number of calls to trigger ANS
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 14
ATT
0
ATT (Attendant Service) type: 0 Start with DCB or RDCB 1 Start with ATTU or ATTD 2 NAO (USA)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 15
ISC
0
Independent Service: 0 Start on CCB 1 Start on DCB 2 Start on ISD/ISU 3 NAO (USA)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 16
CTL-TY
0
Select Car To Landing Type: 0 ETO 1 NAO
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 17
SPEECH
0
Speech Mode: 0 Floor message on CC only 1 Floor message also on HC
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 18
DOC
0
Door Reopen Count: 0 No limit 1 (1) 255 Number of allowed door reopenings
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 19
DS-CCB
0
Disable CCs behind moving car: 0 CCs behind allowed 1 CCs behind not allowed
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 20
DS-DOB
0
Disable DOB button: 0 DOB/RDOB always enabled 1 DOB disabled if door closed 2 RDOB disabled if door closed 3 Both disabled if door closed
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 7 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Group: No.
Symbol
Default
0
GRP-NO
1
Purpose and Range Car identifier in group: 1 (1) 3
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 1
GROUP
1
Number of cars in group: 1 (1) 3
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 2
CNL
1
Cars parking in Lobby: 1 (1) 3
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 3
MIT-ST
0
MIT (Moderate incomming traffic) Startdelay: 0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 4
MIT-T
0
MIT Time-Out: 0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 5
MIT-VD
0
MIT Variable Interval Dispatch: 0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 6
DUPK-P
255
Dual Up Peak Border Position: 0 (1) 31 > 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 7
DUPK-G
0
Dual Up Peak Group: 0 Car belongs to subgroup 1 1 Car belongs to subgroup 2
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 8
MOT-T
0
MOT (Moderate Outgoing traffic) Time-Out: 0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 9
EN-UCB
0
Enable Up Call Bypass: 0 Disabled 1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 10
TFS-P
255
Transfer Floor Position: 0 (1) 31 > 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 11
PARK-1
255
Park Clock Position 1: 0 (1) 31 > 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 12
PARK-2
255
Park Clock Position 2: 0 (1) 31 > 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Symbol
Default
13
PARK-3
255
: 8 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Group (continued): No.
Page
Purpose and Range Park Clock Position 3: 0 (1) 31 > 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 14
PARK-4
255
Park Clock Position 4: 0 (1) 31 > 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 15
PARK-5
255
Park Clock Position 5: 0 (1) 31 > 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 16
PARK-6
255
Park Clock Position 6: 0 (1) 31 > 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 17
PARK-7
255
Park Clock Position 7: 0 (1) 31 > 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 18
PARK-8
255
Park Clock Position 8: 0 (1) 31 > 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 19
EN-ZBS
0
Enable separate basement zone: 0 No free car parks in basement zone 1 A free car parks in basement zone
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 9 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Drive: No.
Symbol
Default
0
DRIVE
1
Purpose and Range Drive Type: 0 1-SP 1 2-SP, G-L 2 G-S/D 3 G-L with SL 4 G-L with SL 5 2-SP, G-L 6 G-S/D 7 SPEC60 8 G-D NAO 9 G-D NAO 10 MOT-VLV 11 SOL-VLV 12 MOT-VLV 13 SOL-VLV 14 LSVF 15 LSVF 16 LSVF-W 17 LSVF-W
XADO XADO XADO ADO ADO ADO XADO ADO ADO ADO XADO XADO ADO XADO ADO XADO
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 1
C-TYPE
2
Controller Type: 0 MCS 310 1 MCS 310 CA, HY 2 MCS 120, MCS 220 3 MCS 220 M
(Europa 2000) (Cargo 2000) (OTIS 2000) (OTIS 2000)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 2
1AT
5
1A Time: 0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 3
2AT
5
2A Time: 0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 4
DDP
32
DDP Time (fast run): 0 (1) 45 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 5
3P
32
3P Time (slow run): 0 (1) 45 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 6
SPEED
100
Speed (fast run mode): 25 40 63 100 160 175 250 cm/s
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 10 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Drive (continued): No.
Symbol
Default
7
EN-MPD
0
Purpose and Range Enable Motor Protection Device: 0 Disabled 1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 8
MPD-T
10
Motor Protection Device Time: 0 (1) 254 s 255 wait forever
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 9
HY-TYP
0
Hydro Drive Type for Hydro: 0 Star - Delta 1 Soft 2 Direct
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 10
L-T
10
Set Star/Soft Time for Hydro: 0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 11
UX-D
20
Set Star/Delta gap / add. Soft Time (L+UX) for Hydro: 0.06 (0.004) 0.2 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 12
UXT-D
0
Set delay between UX and UXT for Hydro: (contract option) 0 (0.1) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 13
EN-PLS
1
Enable PLS1 (Oil-Max-Pressure Limit Switch) for Hydro: 0 Disabled 1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 14
EN-OTS
1
Enable OTS (Oil-Over Temperature Switch) for Hydro: 0 Disabled 1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 15
ACD/UXT
0
Select ACD (Anti Creeping Device) or UXT output for Hydro: 0 ACD and UXT disabled 1 ACD enabled 2 UXT enabled (contract option)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 16
P-OFF-D
0
Set Power Off delay for LSVF-W 0, 255 Disabled 1 (1) 254 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 17
P-ON-D
10
Set Power On delay for LSVF-W 8 (1) 20 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 11 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Drive (continued): No.
Symbol
Default
18
EN-J
1
Purpose and Range Enable 3-Phase Detection (J-Relay) 0 Disabled 1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 19
J-T
1
Number of periods necessary to detect a fault 0 (1) 4
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 20
EN-BCD
1
Enable Brake Current Detection: 0 Disabled 1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 21
BON-D
10
Delay of BCD (after lifted brake) 0 (0.1) 10 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 22
BFLT-T
15
Max. fault time of BCD 0 (0.1) 10 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 23
BOFF-D
15
Delay of BCD (after fallen brake) 0 (0.1) 10 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 12 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Doors: No.
Symbol
Default
0
DOOR
2
Purpose and Range Type of Doors: 0 FLH 1 9550T & ACG 2 9550T & TLD / DO_2000 3 OVL / MRDS 4 OVL & ACG 5 DO_2000 6 MCG 7 Kiekert / MLI & ACG 8 Kiekert / MLI & TLD/CLD
(DC-relay)
(DO-relay)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 1
REAR
2
Type of Rear Doors: 0 FLH 1 9550T & ACG 2 9550T & TLD / DO_2000 3 OVL / MRDS 4 OVL & ACG 5 DO_2000 6 MCG 7 Kiekert / MLI & ACG 8 Kiekert / MLI & TLD/CLD
(DC-relay)
(DO-relay)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 2
EN-DDO
0
Enable DDO (double door operation): 0 Disabled 1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 3
MIXDOR
0
Mixed Dooroperators: 0 Same operators front/rear 1 Different operators front/rear
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 4
DBP-TY
1
Type of Door Bypass circuit: 0 DBP operated (4-relay) 1 LVC operated (3-relay)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 5
SEL-CMR
0
select separate CM relay output (MCS220M) 0 (one door) CMR at RDC-output (P6:10) 1 (two doors) CMR at RSL (IO no. 785) NOTE: only applicable for FLH, MCG, ACG
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 6
LDR
0
Limited Door Reversal: 0 Full DOB, full EDP, full LRD 1 Full DOB, limited EDP, full LRD
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 7
EN-PMO
0
Enable PMO (door time monitoring): 0 Disabled 1 Enabled
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 13 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Doors (continued): No.
Symbol
Default
8
EN-NDG
0
Purpose and Range Enable NDG (nudging): 0 Disabled 1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 9
NDG-T
20
Nudging Time: 0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 10
EN-CK
0
Enable Cancel Doortime with CCB: 0 Disabled 1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 11
DW-DLY
10
Debouncing Time of Door Contact DW: 0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 12
DO-BEL
0
Open Door Bell Timer: 0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 13
MIN-C
20
Min Doortime Car: 0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 14
MAX-C
40
Max Doortime Car: 0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 15
MIN-H
40
Min Doortime Hall: 0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 16
MAX-H
60
Max Doortime Hall: 0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 17
DOR-T
0
Door reverse time: 0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 18
RDOR-T
0
Rear door reverse time: 0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 19
DTC-T
20
Door Close Protection Time: 10 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 20
DTO-T
20
Door Open Protection Time: 10 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 21
LOB-NT
40
Lobby Door Time: 0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 22
CFT-NT
40
Cafeteria Door Time: 0 (0.1) 25.5 s
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 14 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Doors (continued): No.
Symbol
Default
23
SPB-NT
0
Purpose and Range Special DOB Door Time: 0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 24
DHB-T
120
DHB Doortime: 0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 25
WCO-T
0
Wild Car Door Time: 0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 26
SHO-T
0
Shabat Door Time: 0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 27
SHO-LT
0
Shabat Lobby Door Time: 0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 28
DAR-T
60
MPD/Hydro Door Open Time: 0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 29
DXT-T
0
DXT Time (extended door time): 0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 15 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Position Reference No.
Symbol
Default
0
LV-MOD
2
Purpose and Range Leveling Mode: 0 DZ-STP 1
LV-STP
2
DZ-STP
3
IP-STP
4
UIS/DIS
stop with DZ: use DZ-DLY (in 4 ms units) stop with LVU/LVD: for CA-MOD=0 (RLEV-2): set LV-U-D, LV-D-D = 0 for CA-MOD=1 (RLEV-3): use LVU-5D, LVD-5D (in 4 ms units) stop with DZ, 1LV/2LV: use LV-U-D, LV-D-D (in 4 ms units) stop with IPU, IPD: (for 1-Speed Drive) use IPU-D, IPD-D (unit depends on T-BASE) stop with UIS, DIS: (for Hydraulic Drive) use LV-U-D for DIS (in 4 ms units) use LV-D-D for UIS (in 4 ms units)
Note: auto-stop for - Gamma S/D, Spec_60 and Dynalift on RUN signal (110V input) - LSVF-W on RN (coded inputs)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 1
DZ-TYP
0
DZ coding: 0 DZ = 1LV 1 DZ = 1LV and 2LV 2 POSY operation (if neither RLV nor ADO) to stop: DZ = 1LV and 2LV after stop: DZ = 1LV or 2LV
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 2
DZ-DLY
0
Delay for DZ: 0 (0.004) 1 s
(LV-MOD = 0)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 3
LV-U-D
12
Delay for DZ, 1LV/2LV (in up direction): 0 (0.004) 1 s (LV-MOD = 1, 2, 4)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 4
LV-D-D
12
Delay for DZ, 1LV/2LV (in down direction): 0 (0.004) 1 s (LV-MOD = 1, 2, 4)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 5
T-BASE
0
Timebase for IPU-D, IPD-D, 1LS-D and 2LS-D: 0 0.1 s 1 0.004 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 6
IPU-D
0
Delay for IPU: 0 (0.1) 25.5 s 0 (0.004) 1 s
(T-BASE=0) (T-BASE=1)
Delay for IPD: 0 (0.1) 25.5 s 0 (0.004) 1 s
(T-BASE=0) (T-BASE=1)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 7
IPD-D
0
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Symbol
Default
8
1LS-D
0
: 16 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Position Reference (continued): No.
Page
Purpose and Range Delay for 1LS: 0 (0.1) 25.5 s 0 (0.004) 1 s
(T-BASE=0) (T-BASE=1)
Delay for 2LS: 0 (0.1) 25.5 s 0 (0.004) 1 s
(T-BASE=0) (T-BASE=1)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 9
2LS-D
0
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 10
EN-RLV
0
Enable RLV operation: 0 Disabled 1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 11
RLV-TY
0
RLV - Type: 0 RLV 1 DRLV
Relevelling Delayed Relevelling (using DIS1)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 12
RL-CNT
3
Limit of RLV steps: 0 (1) 255
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 13
RL-DIS
255
Set RLV time up (DIS lost): 0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 14
RL-UIS
255
Set RLV time down (UIS lost): 0 (0.1) 25.5 s 0 (0.004) 1 s (hydraulic drive)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 15
RL-U-D
0
Set RLV delay up: 0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 16
RL-D-D
0
Set RLV delay down: 0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 17 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Cargo: No.
Symbol
Default
0
CA-MOD
0
Purpose and Range CARGO mode: 0 RLEV/RLEV-2 1 RLEV-3 2 Class-C2
(not authorized yet)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 1
LVU-5D
0
Delay for LV stop (UP 0.5 load): 0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 2
LVD-5D
0
Delay for LV stop (DOWN 0.5 load): 0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 3
BI-T
0
Class C2: time-out for Bolts In: 0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 4
BO-T
0
Class C2: time-out for Bolts Out: 0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 5
MVU-T
0
Class C2: time-out for Move Up: 0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 6
MVD-T
0
Class C2: time-out for Move Down: 0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 7
PLS4-T
0
Class C2: time-out for PLS4: 0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 18 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Emergency:
R)
Part
No.
Symbol
Default
0
ES-TYP
0
Purpose and Range Define ES-Type: 0 ESS connected 1 ESB connected (closed door will remain closed) 2 ESB connected (closed door will open) 3 ES-input disabled (for LCB_II version GCA 21240 D2 / D3)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 1
EFO-P
255
EFO (emergency fireman operation) position: 0 (1) 31 > 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 2
EFO-DC
0
EFO with doors closed: 0 Disabled 1 (1) 255 s DC time
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 3
EFO-DO
0
EFO default door: 0 Both doors will open at EFO position 1 Only front door opens 2 Only rear door opens
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 4
EFO-OP
0
EFO override option: 0 No override possible 1 XEFO input overrides EFO after arrival at return landing 2 After EFS no EFO is permitted if EFO or AEFO are still active 3 Functions 1 + 2 together
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 5
EFONDG
Enable nudging speed for EFO 0 Door closes with full speed 1 Door closes with nudging speed
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 6
ASL-P
255
ASL (alternate service landing) position: 0 (1) 31 > 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 7
R)
EFS-TY
0
Type of EFS (Emergency Fireman Service) (if EFK (ASL) connected): 0 EFO 1 EFS 1 (Aut.) 2 EFS 2 (Man.) 3 ANSI (USA) 4 British Standard 5 Swiss Standard 6 Australia 7 New Zealand 8 EFS 2 (Man. with ESK)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Symbol
Default
8
EFS-DO
0
: 19 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Emergency (continued): No.
Page
Purpose and Range EFS default door: 0 Both doors will open position 1 Only front door opens 2 Only rear door opens
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 9
EFS-RT
0
EFS return time (time EFK must be low to force car back to EFO landing if EFK is switched on again while in EFS): 0-39 Function disabled 40-255 Time (in 100 ms units) EFK must be low
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 10
EN-BAK
0
Enable E2P-backup of EFO/EFS: 0 Disable backup 1 Enable backup
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 11
HDWPOS
0
Hardware position reference: 0 Disabled 1 One contact per floor 2 Binary coded contacts 3 Signal at every odd floor
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 12
EPO-P
255
EPO (emergency power operation) Position: 0 (1) 31 EPO A/C (position) EPO E (hydro: bottom) = 32 EPO B/D (next floor) EPO F (hydro: next floor down)w >32 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 13
EPO-DC
0
EPO with doors closed: 0 Disabled 1 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 14
EPO-DO
0
EPO default door: 0 Both doors will open at EPO position 1 Only front door opens 2 Only rear door opens
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 15
EPO-PR
0
EPO priority if EFO/EFS: 0 No prio for EPO 1 EPO has priority
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 16
EQO
0
Earthquake Operation Type: 0 California 1 New Zealand
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Symbol
Default
17
EPS-TYP
0
: 20 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Emergency (continued): No.
Page
Purpose and Range Express Priority Service: x0 automatic ISC x1 return to normal x2 automatic CHCS 0x immediate return 1x stop at next commitable 2x serve car calls en route
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 18
EHS-T
0
EHS time-out: 0 Disabled 1 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 21 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Security: No.
Symbol
Default
0
EN-FPD
0
Purpose and Range Enable FPD (fireproof doors): 0 Disabled 1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 1
EN-IST
0
Enable IST (intermittent stop): 0 Disabled 1 In up direction only 2 In down direction only 3 In both directions 5 In up direction only, if ISTS active 6 In down direction only, if ISTS active 7 In both directions, if ISTS active
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 2
IST-P
255
Intermittent Stop Position: 0 (1) 31 >31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 3
EN-CRO
0
Enable CRO (card reader operation): 0 Disabled 1 Single contact reader 2 Australian Card Key sec type 2 3 Australian Card Key sec type 1 4 Multi contact reader
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 4
GCBTYP
0
General Control of Buttons type: 0 disabled 1 GCB_1 2 GCB_2
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 5
RIOT-P
255
RIOT Operation Position: 0 (1) 31 >31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Symbol
Default
6
SACTYP
0
: 22 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Security (continued): No.
Page
Purpose and Range Secure Access Type: 1 SAC enabled, without ISC override 3 SAC enabled, with ISC override 5 SAC enabled, without ISC override, clear only if sec. enabled 7 SAC enabled, with ISC override, clear only if security enabled else SAC disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 7
SAC-D1
255
Secure Access digit 1: 0 (1) 6 >6 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 8
SAC-D2
255
Secure Access digit 2: 0 (1) 6 >6 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 9
SAC-D3
255
Secure Access digit 3: 0 (1) 6 >6 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 23 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Test: No.
Symbol
Default
0
TPOS 1
255
Purpose and Range Test position 1 (automatic test run): 0 (1) 31 > 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 1
TPOS 2
255
Test position 2 (automatic test run): 0 (1) 31 > 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 2
TDELAY
255
Test Delay for automatic test run: 0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 3
NoAdrChk
0
Disable safety check: address of TCI, 1LS and 2LS regarding to Std-IO-List 0 RSL safety check enabled 1 RSL safety check disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 4
NoDW_Chk
0
Disable DW-check during NOR: 0 DW is checked when door open 1 No DW-check during NOR
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 5
DEBUG
0
Debug Parameter: 0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 6
DEBUG1
0
Debug Parameter 1: 0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 7
EN-1CL
0
Enable Init_1CL: default position (Mot_VLV.): 0 Disabled 1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 8
EN-EVT
0
Enable storage of 10 events into E2PROM: 0 Disabled 1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 9
EN-CRT
0
Enable contract handling: Operate up to 32 openings: 0 Disabled 1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
MCS - LCB_II
Index
DOC, 6 DOOR, 12 DOR-T, 13 DO-BEL, 13 DRIVE, 9 DS-CCB, 6 DS-DOB, 6 DTC-T, 13 DTO-T, 13 DUPK-G, 7 DUPK-P, 7 DW-DLY, 13 DXT-T, 14 DZCNT, 4 DZ-DLY, 15 DZ-TYP, 15
A
ACD/UXT, 10 ANS, 6 ARD-P, 5 ARD-T, 5 ASL-P, 18 ATT, 6 B
CA-MOD, 17 CFT-NT, 13 CFT-P, 2 CNL, 7 CONFIG, 2 CPC-TYP, 4 CPR-T, 5 CR-DIR, 4 CTL-DO, 5 CTL-P, 6 CTL-TY, 6 CTL/PKS, 5 C-CHK, 4 C-TYPE, 9 D DAR-T, 14 DBP-TY, 12 DCP-T, 5 DDP, 9 DEBUG, 23 DEBUG1, 23 DHB-T, 14
No.
:
GCA 21240 D VIIIa
Vintage : 01 / 8
List of Installation Parameters
C
: 4 - AA 3
Software Data
PRODUCT ADMINISTRATION
BFLT-T, 11 BI-T, 17 BOFF-D, 11 BON-D, 11 BOTTOM, 2 BO-T, 17
Part
: 24 / 25
Date
: 27-Jun-1995
EN-FPD, 21 EN-HLC, 3 EN-IST, 21 EN-J, 11 EN-MPD, 10 EN-NDG, 13 EN-OTS, 10 EN-PLS, 10 EN-PMO, 12 EN-RLV, 16 EN-RR, 4 EN-SFR, 3 EN-SHB, 5 EN-UCB, 7 EN-ZBS, 8 EN-1CL, 23 EPO-DC, 19 EPO-DO, 19 EPO-P, 19 EPO-PR, 19 EPS-TYP, 20 EQO, 19 ERO-TYP, 4 ES-TYP, 18
E EFONDG, 18 EFO-DC, 18 EFO-DO, 18 EFO-OP, 18 EFO-P, 18 EFS-DO, 19 EFS-RT, 19 EFS-TY, 18 EHS-T, 20 ELD-DOOR, 3 ELD-fCLG, 2 ELD-fOPG, 2 ELD-LNG, 3 ELD-MSG, 3 ELD-rCLG, 3 ELD-rOPG, 2 ELD-Sym1, 3 EN-BAK, 19 EN-BCD, 11 EN-BSM, 2 EN-CK, 13 EN-CRO, 21 EN-CRT, 23 EN-DDO, 12 EN-DZI, 4 EN-EVT, 23
Page
G GCBTYP, 21 GROUP, 7 GRP-NO, 7 H HDL-TY, 3 HDWPOS, 19 HL-SET, 3 HY-TYP, 10 I IPD-D, 15 IPU-D, 15 ISC, 6 IST-P, 21
OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
:
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
J
PARK-2, 7 PARK-3, 8 PARK-4, 8 PARK-5, 8 PARK-6, 8 PARK-7, 8 PARK-8, 8 PI, 2 PKS-DO, 5 PKS-P, 5 PKS-T, 5 PKS-TY, 5 PLS4-T, 17 P-OFF-D, 10 P-ON-D, 10
J-T, 11 L LDR, 12 LOBBY, 2 LOB-NT, 13 LR-T, 3 LVD-5D, 17 LVU-5D, 17 LV-D-D, 15 LV-MOD, 15 LV-U-D, 15 L-PARK, 5 L-T, 10
Page
: 25 / 25
Date
: 27-Jun-1995
TPOS1, 23 TPOS2, 23 T-BASE, 15 U UXT-D, 10 UX-D, 10 W WCO-T, 14 1 1AT, 9 1LS-D, 16
R M MAX-C, 13 MAX-H, 13 MD/AES, 4 MIN-C, 13 MIN-H, 13 MIT-ST, 7 MIT-T, 7 MIT-VD, 7 MIXDOR, 12 MOT-T, 7 MPD-T, 10 MVD-T, 17 MVU-T, 17
RDOR-T, 13 REAR, 12 RIOT-P, 21 RLV-TY, 16 RL-CNT, 16 RL-DIS, 16 RL-D-D, 16 RL-UIS, 16 RL-U-D, 16 S SACTYP, 22 SAC-D1, 22 SAC-D2, 22 SAC-D3, 22 SEL-CMR, 12 SHO-LT, 14 SHO-T, 14 SPB-NT, 14 SPEECH, 6 SPEED, 9
N NDG-T, 13 NoAdrChk, 23 NoDW_Chk, 23 O OPERAT, 2 T P PARK-1, 7
GCA 21240 D VIIIa
TDELAY, 23 TFS-P, 7 TOP, 2
2 2AT, 9 2LS-D, 16 3 3P, 9
View more...