MCS - LCB II List of Parameters

September 4, 2017 | Author: Eneko Diaz De Lezana | Category: Manufactured Goods, Technology, Computing And Information Technology
Share Embed Donate


Short Description

Download MCS - LCB II List of Parameters...

Description

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Page

: 1 / 25

Date

: 27-Jun-1995

MCS - LCB_II List of Installation Parameters

Authorization Date D1: 27-Jun-1995 Running on PCB:

GCA 21240 D1 - D3 GDA 21240 D1 - D3

Software Version:

GAA 30082 BAC

Document Revision: 24 - May - 93 03 - Dec - 93 29 - Apr - 94 02 - Jun - 94 16 - Jun - 94 17 - Jan - 95

- Original Document - OTIS 2000 features add. - Triplex parameter added - Secure Access revised - BSM mode added - MCS220M, LSVF-W, ELD, REM III added 06 - Jun - 95 GAA 30082 BAB A. Gerwing - not distributed 27 - Jun - 95 GAA 30082 BAC A.Gerwing - CPC-TYP, N+2, ELD-MSG, ELD-DOOR GAA 30082 AAA GAA 30082 AAB GAA 30082 AAC GAA 30082 AAD GAA 30082 AAE GAA 30082 BAA

J. Schulte A.Gerwing M. Hnida M. Hnida J. Schulte J. Schulte

Copyright 1995, OTIS GmbH Berlin No part of this document may be copied or reproduced in any form or by any means without the prior written consent of OTIS GmbH.

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Page

: 2 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

System: No.

Symbol

Default

0

TOP

2

Purpose and Range Top position: 1 (1) 31

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 1

LOBBY

0

Lobby position: 0 (1) 31

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 2

BOTTOM

0

Bottom position: 0 (1) 30

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 3

CFT-P

255

Cafeteria Position: 0 (1) 31 > 31 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 4

OPERAT

1

Operation FCL/DCL/SAPB: 0 FCL 1 DCL 2 SAPB

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 5

EN-BSM

0

Enable BSM mode (for DCL: both Up- and Down Hall Calls at lobby): 0 Disabled 1 Enabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 6

CONFIG

0

General configuration: 0 ETO 1 NAO

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 7

PI

4

Type of serial Position Indicator: 0 7/16 Segment 1 Multil. 2 Australian Dot Matrix 3 Australian Dot Matrix with CUDL/CDDL 4 OTIS 2000: LCD and ELD

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 8

ELD-fOPG

20

front door movement time: opening 0 (0.1) 10.0 s 0 = automatic (not yet implem.)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 9

ELD-fCLG

20

front door movement time: closing 0 (0.1) 10.0 s 0 = automatic (not yet implem.)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 10

ELD-rOPG

20

rear door movement time: opening 0 (0.1) 10.0 s 0 = automatic (not yet implem.)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Symbol

Default

11

ELD-rCLG

20

: 3 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

System (continued): No.

Page

Purpose and Range rear door movement time: closing 0 (0.1) 10.0 s 0 = automatic (not yet implem.)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 12

ELD-LNG

5

set Language for ELD: 0 (1) 19 0 SwiGer, 1 SwiFRA, 5 UK, 6 Spain, 10 Sweden, 11 Luxem, 15 Denmar, 16 SthAfr,

2 7 12 17

SwiIta, Nether, Belg, Finlnd,

3 8 13 18

Fra, Ger, Por, Ara,

4 9 14 19

Italy, Aus, Egy, Kuw

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 13

ELD-Sym1

0

Enable Non-Smoking symbol: 0 Disabled 1 symbol is displayed

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq R) 14 ELD-DOOR 0 select type of door display: 0: 1 COP for 1 door or R) 2 COPs for 2 doors R) 1: only 1 COP for 2 doors R) qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq R) 15 ELD-MSG 0 enables customer messages: R) 0: no customer messages are displayed by ELD R) 1: customer messages are enabled (use SETUP-ELD to define the texts) R) qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 16

EN-SFR

0

Enable SFR (signal flicker): 0 Disabled 1 Enabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 17

LR-T

20

FAN (LR) time: 0 (1) 255 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 18

EN-HLC

0

Enable Hall Lanterns on car calls: 0 Disabled 1 HLC 2 HL also during closing 3 HLC and during door closing

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 19

HDL-TY

0

Hall Direction Lantern Type of OTIS 2000 Hall Button Box: 0 Direction Indicator 1 Hall Lantern

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 20

HL-SET

0

Hall Lantern/Gong Setup: 0 HL/G at same pins 1 HL/G at 1 2/3 4 2 HL/G at 3 4/1 2

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Page

: 4 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

System (continued): No.

Symbol

Default

21

CR-DIR

0

Purpose and Range Correction Fast Run Preferred Direction: 0 Down 1 Up

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 22

EN-RR

0

Enable Reduced Run (RR): 0 Disabled 1 Enabled (short or medium run)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 23

DZCNT

1

Use DZ for SL counting (for Short Run): 0 Disabled 1 Enabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 24

EN-DZI

0

Enable DZI (Door Zone Indicator): 0 Disabled 1 Enabled (only if no Door ByPass)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 25

R) R)

ERO-TYP

0

Define ERO type 0 without limit 1 with limit at terminal landings (same as TCI-limit) 2 ERO-input disabled (for LCB_II version D2)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 26

C-CHK

0

Enable C-Circuit Check: 0 Disabled 1 Enabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 27

R) R)

MD/AES

0

select use of MD input (P7:9, only MCS220M): 0 not connected 1 MD: DCS-input for Multi Door (manual plus autom. landing doors) 2 AES: ES-input if RSS or ESB is used

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq

28 CPC-TYP 0 select use of CPC outputs: R) 0 car position contact R) 1 ’car here’ light R) 2 french SSM R) qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq R) 29 N+2 WIRE 0 enable 3 wire buttons: R) 0 normal car and hall buttons 1 3 wire car buttons R) 1 3 wire hall buttons R) 1 3 wire car and hall buttons R) qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Page

: 5 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

OCSS: No.

Symbol

Default

0

CPR-T

20

Purpose and Range Car Call Preference: 0 (0.1) 25.5 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 1

ARD-P

255

Automatic Return Device Position: 0 (1) 31 > 31 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 2

ARD-T

0

Set Delay for ARD (Automayic Return Device) mode: 0 (10) 2550 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 3

L-PARK

0

Lobby Park Option: 0 Disabled 1 Enabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 4

CTL/PKS

0

Select CTL or PKS switch: 0 CTL switch is connected 1 PKS switch is connected

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 5

PKS-P

255

Parking Service Position: 0 (1) 31 > 31 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 6

PKS-TY

0

Parking Shutoff Type: 0 ETO 1 NAO 2 ETO with door open after shutdown

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 7

PKS-T

0

Parking Shutoff Time: 0 (1) 255 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 8

PKS-DO

0

PKS default door: 0 Both doors will open at PKS-P 1 Only front door opens 2 Only rear door opens

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 9

EN-SHB

0

Enable Separate Hall Buttons: 0 Normal HB-operation 1 Rear HB as Separate Riser

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 10

DCP-T

50

Time until DCP-mode (delayed car protection): 25 (1) 255 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 11

CTL-DO

0

CTL default door (car to any landing): 0 Both doors will open at CTL-P 1 Only front door opens 2 Only rear door opens

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Page

: 6 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

OCSS (continued): No.

Symbol

Default

12

CTL-P

255

Purpose and Range CTL (Car To Any Landing) position: 0 (1) 31 > 31 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 13

ANS

0

ANS (anti nuisance service): 0 Disabled >0 Number of calls to trigger ANS

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 14

ATT

0

ATT (Attendant Service) type: 0 Start with DCB or RDCB 1 Start with ATTU or ATTD 2 NAO (USA)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 15

ISC

0

Independent Service: 0 Start on CCB 1 Start on DCB 2 Start on ISD/ISU 3 NAO (USA)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 16

CTL-TY

0

Select Car To Landing Type: 0 ETO 1 NAO

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 17

SPEECH

0

Speech Mode: 0 Floor message on CC only 1 Floor message also on HC

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 18

DOC

0

Door Reopen Count: 0 No limit 1 (1) 255 Number of allowed door reopenings

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 19

DS-CCB

0

Disable CCs behind moving car: 0 CCs behind allowed 1 CCs behind not allowed

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 20

DS-DOB

0

Disable DOB button: 0 DOB/RDOB always enabled 1 DOB disabled if door closed 2 RDOB disabled if door closed 3 Both disabled if door closed

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Page

: 7 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

Group: No.

Symbol

Default

0

GRP-NO

1

Purpose and Range Car identifier in group: 1 (1) 3

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 1

GROUP

1

Number of cars in group: 1 (1) 3

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 2

CNL

1

Cars parking in Lobby: 1 (1) 3

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 3

MIT-ST

0

MIT (Moderate incomming traffic) Startdelay: 0 (1) 255 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 4

MIT-T

0

MIT Time-Out: 0 (1) 255 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 5

MIT-VD

0

MIT Variable Interval Dispatch: 0 (1) 255 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 6

DUPK-P

255

Dual Up Peak Border Position: 0 (1) 31 > 31 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 7

DUPK-G

0

Dual Up Peak Group: 0 Car belongs to subgroup 1 1 Car belongs to subgroup 2

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 8

MOT-T

0

MOT (Moderate Outgoing traffic) Time-Out: 0 (1) 255 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 9

EN-UCB

0

Enable Up Call Bypass: 0 Disabled 1 Enabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 10

TFS-P

255

Transfer Floor Position: 0 (1) 31 > 31 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 11

PARK-1

255

Park Clock Position 1: 0 (1) 31 > 31 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 12

PARK-2

255

Park Clock Position 2: 0 (1) 31 > 31 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Symbol

Default

13

PARK-3

255

: 8 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

Group (continued): No.

Page

Purpose and Range Park Clock Position 3: 0 (1) 31 > 31 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 14

PARK-4

255

Park Clock Position 4: 0 (1) 31 > 31 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 15

PARK-5

255

Park Clock Position 5: 0 (1) 31 > 31 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 16

PARK-6

255

Park Clock Position 6: 0 (1) 31 > 31 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 17

PARK-7

255

Park Clock Position 7: 0 (1) 31 > 31 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 18

PARK-8

255

Park Clock Position 8: 0 (1) 31 > 31 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 19

EN-ZBS

0

Enable separate basement zone: 0 No free car parks in basement zone 1 A free car parks in basement zone

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Page

: 9 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

Drive: No.

Symbol

Default

0

DRIVE

1

Purpose and Range Drive Type: 0 1-SP 1 2-SP, G-L 2 G-S/D 3 G-L with SL 4 G-L with SL 5 2-SP, G-L 6 G-S/D 7 SPEC60 8 G-D NAO 9 G-D NAO 10 MOT-VLV 11 SOL-VLV 12 MOT-VLV 13 SOL-VLV 14 LSVF 15 LSVF 16 LSVF-W 17 LSVF-W

XADO XADO XADO ADO ADO ADO XADO ADO ADO ADO XADO XADO ADO XADO ADO XADO

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 1

C-TYPE

2

Controller Type: 0 MCS 310 1 MCS 310 CA, HY 2 MCS 120, MCS 220 3 MCS 220 M

(Europa 2000) (Cargo 2000) (OTIS 2000) (OTIS 2000)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 2

1AT

5

1A Time: 0 (0.1) 25.5 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 3

2AT

5

2A Time: 0 (0.1) 25.5 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 4

DDP

32

DDP Time (fast run): 0 (1) 45 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 5

3P

32

3P Time (slow run): 0 (1) 45 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 6

SPEED

100

Speed (fast run mode): 25 40 63 100 160 175 250 cm/s

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Page

: 10 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

Drive (continued): No.

Symbol

Default

7

EN-MPD

0

Purpose and Range Enable Motor Protection Device: 0 Disabled 1 Enabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 8

MPD-T

10

Motor Protection Device Time: 0 (1) 254 s 255 wait forever

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 9

HY-TYP

0

Hydro Drive Type for Hydro: 0 Star - Delta 1 Soft 2 Direct

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 10

L-T

10

Set Star/Soft Time for Hydro: 0 (0.1) 25.5 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 11

UX-D

20

Set Star/Delta gap / add. Soft Time (L+UX) for Hydro: 0.06 (0.004) 0.2 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 12

UXT-D

0

Set delay between UX and UXT for Hydro: (contract option) 0 (0.1) 1 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 13

EN-PLS

1

Enable PLS1 (Oil-Max-Pressure Limit Switch) for Hydro: 0 Disabled 1 Enabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 14

EN-OTS

1

Enable OTS (Oil-Over Temperature Switch) for Hydro: 0 Disabled 1 Enabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 15

ACD/UXT

0

Select ACD (Anti Creeping Device) or UXT output for Hydro: 0 ACD and UXT disabled 1 ACD enabled 2 UXT enabled (contract option)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 16

P-OFF-D

0

Set Power Off delay for LSVF-W 0, 255 Disabled 1 (1) 254 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 17

P-ON-D

10

Set Power On delay for LSVF-W 8 (1) 20 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Page

: 11 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

Drive (continued): No.

Symbol

Default

18

EN-J

1

Purpose and Range Enable 3-Phase Detection (J-Relay) 0 Disabled 1 Enabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 19

J-T

1

Number of periods necessary to detect a fault 0 (1) 4

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 20

EN-BCD

1

Enable Brake Current Detection: 0 Disabled 1 Enabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 21

BON-D

10

Delay of BCD (after lifted brake) 0 (0.1) 10 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 22

BFLT-T

15

Max. fault time of BCD 0 (0.1) 10 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 23

BOFF-D

15

Delay of BCD (after fallen brake) 0 (0.1) 10 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Page

: 12 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

Doors: No.

Symbol

Default

0

DOOR

2

Purpose and Range Type of Doors: 0 FLH 1 9550T & ACG 2 9550T & TLD / DO_2000 3 OVL / MRDS 4 OVL & ACG 5 DO_2000 6 MCG 7 Kiekert / MLI & ACG 8 Kiekert / MLI & TLD/CLD

(DC-relay)

(DO-relay)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 1

REAR

2

Type of Rear Doors: 0 FLH 1 9550T & ACG 2 9550T & TLD / DO_2000 3 OVL / MRDS 4 OVL & ACG 5 DO_2000 6 MCG 7 Kiekert / MLI & ACG 8 Kiekert / MLI & TLD/CLD

(DC-relay)

(DO-relay)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 2

EN-DDO

0

Enable DDO (double door operation): 0 Disabled 1 Enabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 3

MIXDOR

0

Mixed Dooroperators: 0 Same operators front/rear 1 Different operators front/rear

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 4

DBP-TY

1

Type of Door Bypass circuit: 0 DBP operated (4-relay) 1 LVC operated (3-relay)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 5

SEL-CMR

0

select separate CM relay output (MCS220M) 0 (one door) CMR at RDC-output (P6:10) 1 (two doors) CMR at RSL (IO no. 785) NOTE: only applicable for FLH, MCG, ACG

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 6

LDR

0

Limited Door Reversal: 0 Full DOB, full EDP, full LRD 1 Full DOB, limited EDP, full LRD

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 7

EN-PMO

0

Enable PMO (door time monitoring): 0 Disabled 1 Enabled

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Page

: 13 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

Doors (continued): No.

Symbol

Default

8

EN-NDG

0

Purpose and Range Enable NDG (nudging): 0 Disabled 1 Enabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 9

NDG-T

20

Nudging Time: 0 (1) 255 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 10

EN-CK

0

Enable Cancel Doortime with CCB: 0 Disabled 1 Enabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 11

DW-DLY

10

Debouncing Time of Door Contact DW: 0 (0.1) 25.5 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 12

DO-BEL

0

Open Door Bell Timer: 0 (0.1) 25.5 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 13

MIN-C

20

Min Doortime Car: 0 (0.1) 25.5 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 14

MAX-C

40

Max Doortime Car: 0 (0.1) 25.5 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 15

MIN-H

40

Min Doortime Hall: 0 (0.1) 25.5 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 16

MAX-H

60

Max Doortime Hall: 0 (0.1) 25.5 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 17

DOR-T

0

Door reverse time: 0 (0.004) 1 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 18

RDOR-T

0

Rear door reverse time: 0 (0.004) 1 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 19

DTC-T

20

Door Close Protection Time: 10 (1) 255 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 20

DTO-T

20

Door Open Protection Time: 10 (1) 255 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 21

LOB-NT

40

Lobby Door Time: 0 (0.1) 25.5 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 22

CFT-NT

40

Cafeteria Door Time: 0 (0.1) 25.5 s

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Page

: 14 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

Doors (continued): No.

Symbol

Default

23

SPB-NT

0

Purpose and Range Special DOB Door Time: 0 (0.1) 25.5 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 24

DHB-T

120

DHB Doortime: 0 (1) 255 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 25

WCO-T

0

Wild Car Door Time: 0 (0.1) 25.5 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 26

SHO-T

0

Shabat Door Time: 0 (0.1) 25.5 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 27

SHO-LT

0

Shabat Lobby Door Time: 0 (0.1) 25.5 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 28

DAR-T

60

MPD/Hydro Door Open Time: 0 (1) 255 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 29

DXT-T

0

DXT Time (extended door time): 0 (0.1) 25.5 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Page

: 15 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

Position Reference No.

Symbol

Default

0

LV-MOD

2

Purpose and Range Leveling Mode: 0 DZ-STP 1

LV-STP

2

DZ-STP

3

IP-STP

4

UIS/DIS

stop with DZ: use DZ-DLY (in 4 ms units) stop with LVU/LVD: for CA-MOD=0 (RLEV-2): set LV-U-D, LV-D-D = 0 for CA-MOD=1 (RLEV-3): use LVU-5D, LVD-5D (in 4 ms units) stop with DZ, 1LV/2LV: use LV-U-D, LV-D-D (in 4 ms units) stop with IPU, IPD: (for 1-Speed Drive) use IPU-D, IPD-D (unit depends on T-BASE) stop with UIS, DIS: (for Hydraulic Drive) use LV-U-D for DIS (in 4 ms units) use LV-D-D for UIS (in 4 ms units)

Note: auto-stop for - Gamma S/D, Spec_60 and Dynalift on RUN signal (110V input) - LSVF-W on RN (coded inputs)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 1

DZ-TYP

0

DZ coding: 0 DZ = 1LV 1 DZ = 1LV and 2LV 2 POSY operation (if neither RLV nor ADO) to stop: DZ = 1LV and 2LV after stop: DZ = 1LV or 2LV

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 2

DZ-DLY

0

Delay for DZ: 0 (0.004) 1 s

(LV-MOD = 0)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 3

LV-U-D

12

Delay for DZ, 1LV/2LV (in up direction): 0 (0.004) 1 s (LV-MOD = 1, 2, 4)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 4

LV-D-D

12

Delay for DZ, 1LV/2LV (in down direction): 0 (0.004) 1 s (LV-MOD = 1, 2, 4)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 5

T-BASE

0

Timebase for IPU-D, IPD-D, 1LS-D and 2LS-D: 0 0.1 s 1 0.004 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 6

IPU-D

0

Delay for IPU: 0 (0.1) 25.5 s 0 (0.004) 1 s

(T-BASE=0) (T-BASE=1)

Delay for IPD: 0 (0.1) 25.5 s 0 (0.004) 1 s

(T-BASE=0) (T-BASE=1)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 7

IPD-D

0

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Symbol

Default

8

1LS-D

0

: 16 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

Position Reference (continued): No.

Page

Purpose and Range Delay for 1LS: 0 (0.1) 25.5 s 0 (0.004) 1 s

(T-BASE=0) (T-BASE=1)

Delay for 2LS: 0 (0.1) 25.5 s 0 (0.004) 1 s

(T-BASE=0) (T-BASE=1)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 9

2LS-D

0

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 10

EN-RLV

0

Enable RLV operation: 0 Disabled 1 Enabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 11

RLV-TY

0

RLV - Type: 0 RLV 1 DRLV

Relevelling Delayed Relevelling (using DIS1)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 12

RL-CNT

3

Limit of RLV steps: 0 (1) 255

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 13

RL-DIS

255

Set RLV time up (DIS lost): 0 (0.1) 25.5 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 14

RL-UIS

255

Set RLV time down (UIS lost): 0 (0.1) 25.5 s 0 (0.004) 1 s (hydraulic drive)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 15

RL-U-D

0

Set RLV delay up: 0 (0.004) 1 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 16

RL-D-D

0

Set RLV delay down: 0 (0.004) 1 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Page

: 17 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

Cargo: No.

Symbol

Default

0

CA-MOD

0

Purpose and Range CARGO mode: 0 RLEV/RLEV-2 1 RLEV-3 2 Class-C2

(not authorized yet)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 1

LVU-5D

0

Delay for LV stop (UP 0.5 load): 0 (0.004) 1 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 2

LVD-5D

0

Delay for LV stop (DOWN 0.5 load): 0 (0.004) 1 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 3

BI-T

0

Class C2: time-out for Bolts In: 0 (0.004) 1 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 4

BO-T

0

Class C2: time-out for Bolts Out: 0 (0.004) 1 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 5

MVU-T

0

Class C2: time-out for Move Up: 0 (0.004) 1 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 6

MVD-T

0

Class C2: time-out for Move Down: 0 (0.004) 1 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 7

PLS4-T

0

Class C2: time-out for PLS4: 0 (0.004) 1 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Page

: 18 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

Emergency:

R)

Part

No.

Symbol

Default

0

ES-TYP

0

Purpose and Range Define ES-Type: 0 ESS connected 1 ESB connected (closed door will remain closed) 2 ESB connected (closed door will open) 3 ES-input disabled (for LCB_II version GCA 21240 D2 / D3)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 1

EFO-P

255

EFO (emergency fireman operation) position: 0 (1) 31 > 31 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 2

EFO-DC

0

EFO with doors closed: 0 Disabled 1 (1) 255 s DC time

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 3

EFO-DO

0

EFO default door: 0 Both doors will open at EFO position 1 Only front door opens 2 Only rear door opens

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 4

EFO-OP

0

EFO override option: 0 No override possible 1 XEFO input overrides EFO after arrival at return landing 2 After EFS no EFO is permitted if EFO or AEFO are still active 3 Functions 1 + 2 together

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 5

EFONDG

Enable nudging speed for EFO 0 Door closes with full speed 1 Door closes with nudging speed

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 6

ASL-P

255

ASL (alternate service landing) position: 0 (1) 31 > 31 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 7

R)

EFS-TY

0

Type of EFS (Emergency Fireman Service) (if EFK (ASL) connected): 0 EFO 1 EFS 1 (Aut.) 2 EFS 2 (Man.) 3 ANSI (USA) 4 British Standard 5 Swiss Standard 6 Australia 7 New Zealand 8 EFS 2 (Man. with ESK)

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Symbol

Default

8

EFS-DO

0

: 19 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

Emergency (continued): No.

Page

Purpose and Range EFS default door: 0 Both doors will open position 1 Only front door opens 2 Only rear door opens

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 9

EFS-RT

0

EFS return time (time EFK must be low to force car back to EFO landing if EFK is switched on again while in EFS): 0-39 Function disabled 40-255 Time (in 100 ms units) EFK must be low

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 10

EN-BAK

0

Enable E2P-backup of EFO/EFS: 0 Disable backup 1 Enable backup

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 11

HDWPOS

0

Hardware position reference: 0 Disabled 1 One contact per floor 2 Binary coded contacts 3 Signal at every odd floor

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 12

EPO-P

255

EPO (emergency power operation) Position: 0 (1) 31 EPO A/C (position) EPO E (hydro: bottom) = 32 EPO B/D (next floor) EPO F (hydro: next floor down)w >32 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 13

EPO-DC

0

EPO with doors closed: 0 Disabled 1 (1) 255 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 14

EPO-DO

0

EPO default door: 0 Both doors will open at EPO position 1 Only front door opens 2 Only rear door opens

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 15

EPO-PR

0

EPO priority if EFO/EFS: 0 No prio for EPO 1 EPO has priority

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 16

EQO

0

Earthquake Operation Type: 0 California 1 New Zealand

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Symbol

Default

17

EPS-TYP

0

: 20 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

Emergency (continued): No.

Page

Purpose and Range Express Priority Service: x0 automatic ISC x1 return to normal x2 automatic CHCS 0x immediate return 1x stop at next commitable 2x serve car calls en route

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 18

EHS-T

0

EHS time-out: 0 Disabled 1 (1) 255 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Page

: 21 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

Security: No.

Symbol

Default

0

EN-FPD

0

Purpose and Range Enable FPD (fireproof doors): 0 Disabled 1 Enabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 1

EN-IST

0

Enable IST (intermittent stop): 0 Disabled 1 In up direction only 2 In down direction only 3 In both directions 5 In up direction only, if ISTS active 6 In down direction only, if ISTS active 7 In both directions, if ISTS active

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 2

IST-P

255

Intermittent Stop Position: 0 (1) 31 >31 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 3

EN-CRO

0

Enable CRO (card reader operation): 0 Disabled 1 Single contact reader 2 Australian Card Key sec type 2 3 Australian Card Key sec type 1 4 Multi contact reader

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 4

GCBTYP

0

General Control of Buttons type: 0 disabled 1 GCB_1 2 GCB_2

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 5

RIOT-P

255

RIOT Operation Position: 0 (1) 31 >31 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Symbol

Default

6

SACTYP

0

: 22 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

Security (continued): No.

Page

Purpose and Range Secure Access Type: 1 SAC enabled, without ISC override 3 SAC enabled, with ISC override 5 SAC enabled, without ISC override, clear only if sec. enabled 7 SAC enabled, with ISC override, clear only if security enabled else SAC disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 7

SAC-D1

255

Secure Access digit 1: 0 (1) 6 >6 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 8

SAC-D2

255

Secure Access digit 2: 0 (1) 6 >6 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 9

SAC-D3

255

Secure Access digit 3: 0 (1) 6 >6 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

Page

: 23 / 25

Date

: 27-Jun-1995

Version: GAA 30082 BAC

Test: No.

Symbol

Default

0

TPOS 1

255

Purpose and Range Test position 1 (automatic test run): 0 (1) 31 > 31 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 1

TPOS 2

255

Test position 2 (automatic test run): 0 (1) 31 > 31 Disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 2

TDELAY

255

Test Delay for automatic test run: 0 (1) 255 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 3

NoAdrChk

0

Disable safety check: address of TCI, 1LS and 2LS regarding to Std-IO-List 0 RSL safety check enabled 1 RSL safety check disabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 4

NoDW_Chk

0

Disable DW-check during NOR: 0 DW is checked when door open 1 No DW-check during NOR

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 5

DEBUG

0

Debug Parameter: 0 (1) 255 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 6

DEBUG1

0

Debug Parameter 1: 0 (1) 255 s

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 7

EN-1CL

0

Enable Init_1CL: default position (Mot_VLV.): 0 Disabled 1 Enabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 8

EN-EVT

0

Enable storage of 10 events into E2PROM: 0 Disabled 1 Enabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq 9

EN-CRT

0

Enable contract handling: Operate up to 32 openings: 0 Disabled 1 Enabled

qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

MCS - LCB_II

Index

DOC, 6 DOOR, 12 DOR-T, 13 DO-BEL, 13 DRIVE, 9 DS-CCB, 6 DS-DOB, 6 DTC-T, 13 DTO-T, 13 DUPK-G, 7 DUPK-P, 7 DW-DLY, 13 DXT-T, 14 DZCNT, 4 DZ-DLY, 15 DZ-TYP, 15

A

ACD/UXT, 10 ANS, 6 ARD-P, 5 ARD-T, 5 ASL-P, 18 ATT, 6 B

CA-MOD, 17 CFT-NT, 13 CFT-P, 2 CNL, 7 CONFIG, 2 CPC-TYP, 4 CPR-T, 5 CR-DIR, 4 CTL-DO, 5 CTL-P, 6 CTL-TY, 6 CTL/PKS, 5 C-CHK, 4 C-TYPE, 9 D DAR-T, 14 DBP-TY, 12 DCP-T, 5 DDP, 9 DEBUG, 23 DEBUG1, 23 DHB-T, 14

No.

:

GCA 21240 D VIIIa

Vintage : 01 / 8

List of Installation Parameters

C

: 4 - AA 3

Software Data

PRODUCT ADMINISTRATION

BFLT-T, 11 BI-T, 17 BOFF-D, 11 BON-D, 11 BOTTOM, 2 BO-T, 17

Part

: 24 / 25

Date

: 27-Jun-1995

EN-FPD, 21 EN-HLC, 3 EN-IST, 21 EN-J, 11 EN-MPD, 10 EN-NDG, 13 EN-OTS, 10 EN-PLS, 10 EN-PMO, 12 EN-RLV, 16 EN-RR, 4 EN-SFR, 3 EN-SHB, 5 EN-UCB, 7 EN-ZBS, 8 EN-1CL, 23 EPO-DC, 19 EPO-DO, 19 EPO-P, 19 EPO-PR, 19 EPS-TYP, 20 EQO, 19 ERO-TYP, 4 ES-TYP, 18

E EFONDG, 18 EFO-DC, 18 EFO-DO, 18 EFO-OP, 18 EFO-P, 18 EFS-DO, 19 EFS-RT, 19 EFS-TY, 18 EHS-T, 20 ELD-DOOR, 3 ELD-fCLG, 2 ELD-fOPG, 2 ELD-LNG, 3 ELD-MSG, 3 ELD-rCLG, 3 ELD-rOPG, 2 ELD-Sym1, 3 EN-BAK, 19 EN-BCD, 11 EN-BSM, 2 EN-CK, 13 EN-CRO, 21 EN-CRT, 23 EN-DDO, 12 EN-DZI, 4 EN-EVT, 23

Page

G GCBTYP, 21 GROUP, 7 GRP-NO, 7 H HDL-TY, 3 HDWPOS, 19 HL-SET, 3 HY-TYP, 10 I IPD-D, 15 IPU-D, 15 ISC, 6 IST-P, 21

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental Operations

Part

: 4 - AA 3

No.

:

Vintage : 01 / 8 Software Data

PRODUCT ADMINISTRATION

MCS - LCB_II List of Installation Parameters

J

PARK-2, 7 PARK-3, 8 PARK-4, 8 PARK-5, 8 PARK-6, 8 PARK-7, 8 PARK-8, 8 PI, 2 PKS-DO, 5 PKS-P, 5 PKS-T, 5 PKS-TY, 5 PLS4-T, 17 P-OFF-D, 10 P-ON-D, 10

J-T, 11 L LDR, 12 LOBBY, 2 LOB-NT, 13 LR-T, 3 LVD-5D, 17 LVU-5D, 17 LV-D-D, 15 LV-MOD, 15 LV-U-D, 15 L-PARK, 5 L-T, 10

Page

: 25 / 25

Date

: 27-Jun-1995

TPOS1, 23 TPOS2, 23 T-BASE, 15 U UXT-D, 10 UX-D, 10 W WCO-T, 14 1 1AT, 9 1LS-D, 16

R M MAX-C, 13 MAX-H, 13 MD/AES, 4 MIN-C, 13 MIN-H, 13 MIT-ST, 7 MIT-T, 7 MIT-VD, 7 MIXDOR, 12 MOT-T, 7 MPD-T, 10 MVD-T, 17 MVU-T, 17

RDOR-T, 13 REAR, 12 RIOT-P, 21 RLV-TY, 16 RL-CNT, 16 RL-DIS, 16 RL-D-D, 16 RL-UIS, 16 RL-U-D, 16 S SACTYP, 22 SAC-D1, 22 SAC-D2, 22 SAC-D3, 22 SEL-CMR, 12 SHO-LT, 14 SHO-T, 14 SPB-NT, 14 SPEECH, 6 SPEED, 9

N NDG-T, 13 NoAdrChk, 23 NoDW_Chk, 23 O OPERAT, 2 T P PARK-1, 7

GCA 21240 D VIIIa

TDELAY, 23 TFS-P, 7 TOP, 2

2 2AT, 9 2LS-D, 16 3 3P, 9

View more...

Comments