Manual Instalação Windows
Short Description
anm2000 windows...
Description
UNM2000 Network Convergence Management System (Based on Windows)
Installation Guide Version: C
Code: MN000001819 MN000001819
FiberHome Telecommunication Telecommunication Technologies Technologies Co., Ltd. December 2015
Thank you for choosing our products. products.
We appreciate your business. Your satisfaction is our goal. We will provide you with comprehensive technical support and afterafter-sal sales es servic service. e. Please Please contac contactt your your local local sales sales representative, service representative or distributor for any help needed at the contact information shown below.
Fiberhome Telecommunication Technologies Co., Ltd.
Address: No. 67, Guanggu Chuangye Jie, Wuhan, Hubei, China Zip code: 430073 Tel: el:
+6 03 7960 7960 0860 0860/0 /088 884 4 (for (for Mala Malays ysia ia)) +91 98 9985 5448 (for South Asia) +593 4 501 4529 (for South America)
Fax:
+86 27 8717 8521
Website: http://www.fiberhomegroup.com http://www.fiberhomegroup.com
Legal Notice
are trademarks of FiberHome Telecommunication Technologies Co., Ltd. (Hereinafter referred to as FiberHome) All brand names and product names used in this document are used for identification purposes only and are trademarks or registered trademarks of their respective holders.
All rights reserved No part of this document (including the electronic version) may be reproduced or transmitted in any form or by any means without prior written permission from FiberHome. Information in this document is subject to change without notice.
Preface
Related Documentation Document
Description
UNM2000 Network Convergence
Introduces the functions, application scenarios and
Management System Product
technical specifications of the UNM2000 Network
Description
Convergence Management System.
UNM2000 Network Convergence
Introduces how to install the UNM2000 Network
Management System Installation
Convergence Management System on the Windows
Guide (Based on Windows)
operating system.
UNM2000 Network Convergence
Introduces how to install the UNM2000 Network
Management System Installation
Convergence Management System on the SUSE Linux
Guide (Based on SUSELinux)
operating system.
UNM2000 Network Convergence Management System Operation Guide
Introduces the operation guidelines of the UNM2000 Network Convergence Management System.
I
Version Version
Description
A
Initial version.
B
Revises the software and hardware configuration requirements. u
Revises the method of installing the client end through Web.
u
Adds the configuration requirements for Internet protocol in the
C
software and hardware configuration. u
Adds the operation procedures for deleting the JAVA cache in Verifying the Upgrade of the Server End
Intended Readers This manual is intended for the following readers: u
Project commissioning engineers
u
Commissioning engineers
u
Operation and maintenance engineers
To utilize this manual, the knowledge on the basic operations of the Windows Server 2008 is necessary.
II
Conventions Terminology Conventions Terminology
Convention FiberHome UNM2000 Network Convergence Management
UNM2000
System
Symbol Conventions Symbol
Convention Note
Caution
➔
Description Important features or operation guide. Possible injury to persons or systems, or cause traffic interruption or loss.
Warning
May cause severe bodily injuries.
Jump
Jumps to another step.
Cascading →
menu Bidirectional ↔
service Unidirectional →
service
Connects multi-level menu options.
The service signal is bidirectional.
The service signal is unidirectional.
III
Operation Safety Rules
The network management computer should be placed away from direct sunlight, electromagnetic interference, heat source, humidity and dust, and with at least 8cm distance from other objects in order to keep good ventilation. Use UPS power supply to avoid loss of network management data caused by accidental power failure. The computer case, UPS power supply and switch (or hub) should be connected to protection earth ground. To shut down the network management computer, first exit the operation system normally and then shut off the power supply. Do not exit the network management system when it is working normally. Exiting the network management system does not interrupt traffic in the network, but precludes centralized control of the networked equipment. The network management computer cannot be used for purposes other than network management. Use of unidentified memory devices should be prohibited so as to avoid computer viruses. Do not delete any file in the network management system randomly or copy any irrelevant file into the network management computer. Do not visit Internet via the network management computer. Doing so may increase data flow in the net card and hence affects normal network management data transmission or results in other accidents.
V
Do not perform service configuration or expansion during service busy hours via the network management system. Do not modify the network management computer s protocol settings, computer name or LAN settings. Doing so may result in abnormal operation of network management system. ’
VI
VII
VIII
IX
Contents
Preface...................................................................................................................I Related Documentation ...................................................................................I Version...........................................................................................................II Intended Readers ...........................................................................................II Conventions ..................................................................................................III Operation Safety Rules......................................................................................... V 1
2
Installation Overview.......................................................................................1 1.1
Operating Mode................................................................................2
1.2
System Configuration Requirements .................................................2
2.2
1.2.2
Software Configuration Requirements .................................5
Initial Installation ...............................................................................8 2.1.1
Installing the Server End for the First Time...........................8
2.1.2
Installing the Client End for the First Time..........................10
Upgrade Installation........................................................................11
Installing the UNM2000.................................................................................14 3.1
3.2
4
Hardware Configuration Requirements................................3
Installation Flow..............................................................................................7 2.1
3
1.2.1
Installing the Server End .................................................................15 3.1.1
Configuring the System Environment ................................15
3.1.2
Installing the SQL Server Database...................................18
3.1.3
Installing the MySQL Database.........................................31
3.1.4
Installing the UNM2000 Software ......................................39
3.1.5
Initializing the Database Table...........................................48
3.1.6
Checking Services............................................................50
Installing the Client End ..................................................................51 3.2.1
Installing the JRE..............................................................51
3.2.2
Installing the Client End of the UNM2000...........................54
Upgrading the UNM2000 ..............................................................................64
5
4.1
Preparation for Upgrade..................................................................65
4.2
Backing Up the Original Configuration Data.....................................65
4.3
Backing Up the Software Package ..................................................66
4.4
Uninstalling the Current Version ......................................................67
4.5
Installing the Upgrade Version.........................................................70
4.6
Importing the Configuration Data.....................................................71
4.7
Verifying the Upgrade of the Server End ..........................................72
FAQ..............................................................................................................76 5.1
How to View the Installation / Uninstallation Logs.............................77
5.2
How to View the Java Version .........................................................77
5.3
How to Uninstall the MySQL Database............................................78
5.4
How to Uninstall the Tomcat ............................................................80
5.5
How to View the Occupation of System Ports ..................................81
Appendix A
Abbreviations ............................................................................83
Figures
Figure 2-1
Flowchart of Installing the Server End for the First Time (for MySQL) .9
Figure 2-2
Flowchart of Installing the Server End for the First Time (for SQL Server) ...........................................................................................10
Figure 2-3
Flowchart of Installing the Client End for the First Time ....................11
Figure 2-4
Flowchart of Upgrading the Server End ...........................................12
Tables
Table 1-1
Hardware Configuration Requirements of the Server End ..................3
Table 1-2
Hardware Configuration Requirements of the Client End ...................5
Table 1-3
Software Configuration Requirements of the Server End ...................6
Table 1-4
Software Configuration Requirements of the Client End.....................6
Table 3-1
Custom Rule Settings .....................................................................16
Table 3-2
The my.ini File Parameter Configuration Table................................33
Table 3-3
Description of the MySQL Database Information .............................45
Table 3-4
Description of the SQL Server Database Information .......................45
Table 3-5
Initialization Procedure Description .................................................49
Table 3-6
UNM2000 Relevant Services ..........................................................51
1
Installation Overview Before installing the UNM2000, you should be familiar with the operating mode and configuration requirement of the UNM2000, so as to complete the installation smoothly.
Operating Mode System Configuration Requirements
Version: C
1
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
1.1
Operating Mode The UNM2000 uses the client / server architecture. The UNM2000 client end and sever end can be installed on one computer, or respectively on two computers. The server end supports the access and operations of multiple client ends. The installation package of the UNM2000 includes the following four components and you can select the components to be installed as required. u
Client: the client end distribution program of the UNM2000.
u
Server: the server end program of the UNM2000.
u
MySQL: MySQL database program.
u
SQL Server: SQL Server database program.
Note: u
It is recommended that you install the client end distribution program and the server end program of the UNM2000 on one computer. This manual introduces the installation procedures on the presumption that the two programs are to be installed on a same computer.
u
The UNM2000 supports the remote installation of the client end. You can access the server in which the client end distribution program locates to download and install the client end via the IE browser.
u
If the MySQL database is to be used, you can install it using the UNM2000 installation package; if the SQL server database is to be used, you need to install it independently before installing the UNM2000.
1.2
System Configuration Requirements The following introduces the hardware and software configuration requirements for the computer on which the UNM2000 is to be installed.
2
Version: C
1 Installation Overview
1.2.1
Hardware Configuration Requirements
Server End The hardware configuration requirements of the UNM2000 server vary according to the network scale. For detailed requirements, see Table 1-1. Table 1-1 Network
Hardware Configuration Requirements of the Server End
CPU Clock Rate
Scale
CPU
Mem-
Hard
Quantity
ory
Disk
Hard Disk Format
Network Card
Space The format of the disk
Equivalent to
on which the
more than 1000 OLTs that are fully configured and
database and the Intel E7-8837 (8core), 2.6GHz
4
64G
4*600GB
Gb dual-port network cards
be NTFS The format of the disk
Equivalent to
on which the
500 to 1000 OLTs that are
Intel XeonE7-
fully
4610V2 (8-core),
configured and
2.3GHz
Version: C
Embedded double
respectively) should
with ONUs
with ONUs
installed (disk C and disk D by default
connected
connected
UNM2000 will be
database and the 4
32G
4*600GB
UNM2000 will be installed (disk C and disk D by default
Embedded double Gb dual-port network cards
respectively) should be NTFS
3
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
Table 1-1 Network
Hardware Configuration Requirements of the Server End (Continued)
CPU Clock Rate
Scale
CPU
Mem-
Hard
Quantity
ory
Disk
Hard Disk Format
Network Card
Space The format of the disk
Equivalent to
on which the
100 to 500 OLTs that are
Intel XeonE5-
fully
2667V2 (8-core),
configured and
3.3GHz
database and the 2
32G
2*600GB
Gb dual-port network cards
be NTFS The format of the disk
Equivalent to
on which the
less than 100 OLTs that are
Intel XeonE5-
fully
2430V2 (6-core),
configured and
2.5 GHz
4
Embedded double
respectively) should
with ONUs
with ONUs
installed (disk C and disk D by default
connected
connected
UNM2000 will be
database and the 2
16G
2*600GB
UNM2000 will be installed (disk C and disk D by default
Embedded single Gb dual-port network card
respectively) should be NTFS
Version: C
1 Installatio Installation n Overview Overview
Client End Table 1-2 shows 1-2 shows the hardware configuration requirements of the UNM2000 client end. Table 1-2 Network Sca Scale
Hardware Hardware Configura Configuration tion Requireme Requirements nts of the Client Client End End
CPU Clock Rate
CPU
Mem-
Hard Disk
Hard Disk
Quantity
ory
Space
Format
Equivalent to
The format of the
more than 1000 OLTs that are fully configured and
disk on which the Intel XeonE5-2637V2 (4-core), 3.5GHz
1
16G
1*2TB
UNM2000 will be
1 GB discrete
installed (disk D
graphics
by default)
connected with
should be NTFS
ONUs Equivalent to
The format of the
500 to 1000
disk on which the
OLTs that are
Intel i3-4130 (2-core),
fully configured
3.4GHz
1
8G
1*1TB
UNM2000 will be
1 GB discrete
installed (disk D
graphics
and connected
by default)
with ONUs
should be NTFS
Equivalent to
The format of the
100 to 500 OLTs that are fully configured and connected
Intel Core i5-4200U (1. 6G-2.6G/3M) (2-core),
1
8G
1*500GB
3.4GHz
disk on which the
nVIDIA
UNM2000 will be
GT720M 1GB
installed (disk D
discrete
by default)
graphics
with ONUs
should be NTFS
Equivalent to
The format of the
less than 100 OLTs that are fully configured and connected
disk on which the
Intel Corei5-4200U (1. 6G-2.6G/3M) (2-core),
1
3.4GHz
with ONUs
1.2.2
Video Card
4G
1*500GB
UNM2000 will be installed (disk D by default)
Intel HD 4400 integrated graphics
should be NTFS
Software Configuration Configuration Requirements Requirements The software requirements for the computer running the UNM2000 server end are as shown in Table 1-3. 1-3.
Version: Version: C
5
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
Table 1-3
Software Software Configura Configuration tion Requiremen Requirements ts of the Server Server End
Conf Config igur urat atio ion n Item Item
Requ Requir irem emen entt Windows Server 2008 R2 Standard (64-bit)
Operating System
SUSELinux Enterprise 11 (64-bit) Solaris 11 (64-bit) SQL Server 2008 R2
Database
MySQL 5.5
JRE
JRE 1.6.0
Internet protocol
TCP/IPv4 and TCP/IPv6
The software requirements for the computer running the UNM2000 client end are as shown in Table 1-4. 1-4. Table 1-4
Software Software Configura Configuration tion Requiremen Requirements ts of the Client Client End
Conf Config igur urat atio ion n Item Item
Requ Requir irem emen entt
Operating System
Windows 7 or Windows 8
JRE
JRE 1.6.0
Internet protocol
TCP/IPv4 and TCP/IPv6
Caution: u
Before installing the UNM2000 server server or client, uninstall the JER JER of the version other than JRE 1.6.0 on the computer.
u
SNMP is the network management management standard based on the TCP/IP TCP/IP protocol suite, and therefore the TCP/IPv4 and TCP/IPv6 protocols should be installed both at the UNM2000 server end and client end.
6
Version: C
2
Installation Flow The installation includes the initial installation and upgrade installation. You can install the UNM2000 according to the installation flowchart.
Initial Installation Upgrade Installation
Version: Version: C
7
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
2.1
Initial Installation The following introduces how to install the server end and the client end for the first time.
2.1.1
Installing the Server End for the First Time When installing the UNM2000 for the first time on Windows operating system (OS), you can refer to the flowchart shown in Figure 2-1 or Figure 2-2 according to the type of database to be used.
Note: The JRE software will be installed by default during installing the UNM2000.
8
Version: C
2 Installation Flow
Figure 2-1
Version: C
Flowchart of Installing the Server End for the First Time (for MySQL)
9
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
Figure 2-2
2.1.2
Flowchart of Installing the Server End for the First Time (for SQL Server)
Installing the Client End for the First Time When installing the UNM2000 client end for the first time under the Windows operating system, users can refer to the flowchart shown in Figure 2-3.
10
Version: C
2 Installation Flow
Figure 2-3
2.2
Flowchart of Installing the Client End for the First Time
Upgrade Installation
Upgrading the Server End When upgrading the UNM2000 server end on the Windows OS, you can refer to the flowchart shown in Figure 2-4.
Version: C
11
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
Figure 2-4
12
Flowchart of Upgrading the Server End
Version: C
2 Installation Flow
Upgrading the Client End The UNM2000 supports automatic upgrading of the client end. Upon startup, the client end will check for updates and upgrade itself automatically, so as to synchronize the version of the client end with the server end.
Version: C
13
3
Installing the UNM2000 The following introduces how to install the UNM2000 for the first time on the Windows OS.
Installing the Server End Installing the Client End
14
Version: C
3 Installing the UNM2000
3.1
Installing the Server End The following introduces how to install the UNM2000 server end for the first time on the Windows OS.
3.1.1
Configuring the System Environment To ensure the security of the system, the system firewall denies the access to the system ports. In order to use the UNM2000 normally, you need to enable the firewall and set a firewall custom rule to allow the UNM2000 to access specific ports.
Prerequisite You have logged into the Windows OS as the Administrator.
Procedure 1.
Select Start
Administrative Tool
→
Windows Firewall with Advanced
→
Security to open the Windows Firewall with Advanced Security window. 2.
Select the Inbound Rule or Outbound Rule in the left pane and click New Rule in the right pane to open the New Inbound Rule Wizard or New Outbound Rule Wizard dialog box.
3. Version: C
Select Port and click Next. 15
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
4.
See Table 3-1 to select the corresponding protocol, enter the port number and click Next. The port 3306 is used as an example to introduce how to add an inbound rule.
Table 3-1 Source
Custom Rule Settings Protocol
Network
Destination
Source Port
Port
Additional
Description
Options The port to be
0/0
TCP
52001:52399
52001:52399
Description information
used by the ICE or the application program.
0/0
UDP
161
161
0/0
UDP
162
162
0/0
TCP
3306
3306
Description information
ManagerTRAP
Description
port.
information Description
MySQL
information
database port The Web client distribution port. It is 8080
0/0
TCP
8080
8080
Description information
by default. Specify the port number according to the actual situation.
16
Version: C
3 Installing the UNM2000
Version: C
5.
Select Allow the connection and click Next.
6.
Select Domain, Private and Public, and then click Next.
17
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
7.
Enter 3306 in the Name textbox and relevant description in the Description (optional) textbox. Then click Finish to complete adding the inbound rule for the port.
8.
3.1.2
Repeat Step 2 to 7 until all inbound and outbound rules are added.
Installing the SQL Server Database The following introduces how to in the SQL server database.
Prerequisite u
The hardware and software configurations of the server meet the requirements described in System Configuration Requirements.
u
The NET Framework 3.5 SP1 component is installed.
u
If Microsoft Visual Studio 2008 is installed on the server, you need to install the VS-2008 sp1 first.
u
18
The SQL Server2008 installation package is obtained.
Version: C
3 Installing the UNM2000
Note: If the MySQL database is to be adopted, skip the procedures in this section because it will be installed during the UNM2000 software installation. Procedure 1.
Double-click SQLFULL_x86_CHS.exe to decompress it.
2.
Double-click setup.exe in the file folder to open the SQL Server Installation Center dialog box.
3.
Click Installation in the left pane, and select New installation or add features to an existing installation. in the right pane.
Version: C
19
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
4.
The system will check the installation program support rules. Then click OK in the SQL Server 2008 R2 Setup dialog box that appears.
Note: If the check fails, you need to solve all problems causing failures according to the prompt, and then reinstall the SQL server database.
20
Version: C
3 Installing the UNM2000
5.
Select the SQL Server 2008 R2 version to be installed, type the product key, and click Next.
Version: C
21
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
22
6.
Select I accept the license terms, and click Next.
7.
Click Install to install the program support files.
Version: C
3 Installing the UNM2000
8.
The system will check the installation program support rules. Then click Next in the SQL Server 2008 R2 Setup dialog box that appears.
Note: If the check fails, you need to solve all problems causing failures according to the prompt, and then reinstall the SQL server database.
9.
Version: C
Select SQL Server Feature Installation, and then click Next.
23
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
10.
Select the components to be installed and click Next. It is recommended to select the functional components to be installed according to the following figure. You can also click Select All to install all components.
24
Version: C
3 Installing the UNM2000
11.
Version: C
The system will check the installation rules. Then click Next.
25
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
26
12.
Adopt the default settings (recommended), and click Next.
13.
View the disk space summary, and click Next.
Version: C
3 Installing the UNM2000
14.
Configure the server. 1)
Click Use the same account for all SQL Server services, select NT AUTHORITY\NETWORK SERVICE as the account name and click OK.
2) 15.
Version: C
Click Next in the displayed SQL Server 2008 R2 Setup dialog box.
Configure the database engine.
27
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
1)
Click Mixed Mode (SQL Server authentication and Windows authentication), and type the password of the SQL Server system administrator in the Enter password and Confirm password text boxes. The password unm2K10 is recommended.
2) 16.
28
Click Add Current User and click Next.
Do not select sending the error reports, and then click Next.
Version: C
3 Installing the UNM2000
17.
Version: C
The system will check the installation configuration rules. Then click Next.
29
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
18.
Verify the functions of SQL Server 2008 R2 to be installed, and click Install.
19.
After the installation is completed, click Close in the dialog box as shown below.
30
Version: C
3 Installing the UNM2000
3.1.3
Installing the MySQL Database The MySQL database supports two installation modes: installation-required and installation-free. The installation-free mode is recommended. This manual uses the installation-free mode as an example to introduce how to install the MySQL database. The name of the installation-free package is MySQL 5.5.34.rar .
Prerequisite u
The hardware and software configurations of the server meet the requirements described in System Configuration Requirements.
u
A static IP address is assigned for the UNM2000 server.
1.
Decompress the installation package to disk D.
Procedure
Decompress the MySQL file folder to the root directory of disk D of the network management server.
Version: C
31
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
Caution: The MySQL database must be installed on disk D; otherwise running the UNM2000 may fail. 2.
Install the MySQL database service. 1)
Select Start
Run, and type cmd in the Open text box of the dialog box
→
that appears, as shown below:
2)
Click OK to open the CLI window and then execute the following commands.
C:\Document and Settings\Administrator> d:
D:\> cd MySQL\bin
D:\ MySQL\bin> mysqld.exe -install MySQL --defaults-file=\"d:\MySQL\my.ini\"
If Service successfully installed is displayed, the service is installed successfully, as shown below.
32
Version: C
3 Installing the UNM2000
Note: After being installed, the MySQL database service appears in the Services window. 3) 3.
Close the CLI window.
Configure the MySQL parameters. 1)
Open the my.ini file in the D:\MySQL\ directory.
2)
See Table 3-2 to set the corresponding parameters in the my.ini file.
Table 3-2
The my.ini File Parameter Configuration Table
Parameter [client]
Value
key_buffer_size
256M
max_allowed_packet
64M
table_open_cache
256
sort_buffer_size
1M
read_buffer_size
1M
read_rnd_buffer_size
4M
myisam_sort_buffer_size
64M
thread_cache_size
8
query_cache_size
16M
thread_concurrency
8
max_connections
500
#default-character-set
gbk
[mysqld]
Version: C
gbk
default-character-set
33
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
Table 3-2
The my.ini File Parameter Configuration Table (Continued)
Parameter
Value character-set-server
gbk
#log-bin
mysql-bin
#binlog_format
mixed
innodb_data_home_dir
D:\MySQL\data/
innodb_data_file_path
ibdata1:256M:autoextend
#innodb_log_group_home_dir innodb_buffer_pool_size
[mysqldump]
4.
512M
innodb_additional_mem_pool_size
8M
innodb_log_file_size
256M
innodb_log_buffer_size
8M
innodb_flush_log_at_trx_commit
2
innodb_file_per_table
1
innodb_lock_wait_timeout
50
max_allowed_packet
64M
key_buffer_size
128M
sort_buffer_size
128M
[myisamchk]
3)
C:\mysql\data/
read_buffer
2M
write_buffer
2M
Save the my.ini file.
Open the Services window to start up the MySQL database service. 1)
Select Start
Administrative Tools
→
Services to open the Services
→
window, and then select the MySQL item, as shown below.
34
Version: C
3 Installing the UNM2000
2)
Right-click MySQL and select Properties from the shortcut menu to open the MySQL Properties (Local Computer) dialog box.
Version: C
35
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
3)
Select Automatic from the Startup type drop-down list and click Start to start the MySQL service. After the service is started up, the process box will be closed automatically.
4)
Click OK in the MySQL Properties (Local Computer) dialog box. The Status of MySQL will turn into Started in the Services window.
Subsequent Procedure After installing the MySQL database, configure the environment variables of the database. The configuration procedures are as follows:
36
Version: C
3 Installing the UNM2000
Caution: The JAVA version cannot be queried if the environment variables of the database are not configured. For the query method, see How to View the Java Version. 1.
On the desktop of the UNM2000 server, right-click Computer and select Properties from the shortcut menu to open the System Properties dialog box.
2.
In the System Properties dialog box, select the Advanced tab, as shown below.
3.
In the Advanced tab, click Environment Variables to open the Environment Variables dialog box, as shown below.
Version: C
37
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
4.
In the System variables list box, Select the Path variable and click Edit to open the Edit System Variable dialog box, as shown below.
5.
Add the variable value %JAVA_HOME%\bin;D:\MySQL\bin; and then click OK.
Note: Different variable values should be separated by semicolons.
38
Version: C
3 Installing the UNM2000
3.1.4
Installing the UNM2000 Software The following introduces how to install the UNM2000 for the first time on the Windows OS.
Prerequisite u
The hardware and software configurations of the server meet the requirements described in System Configuration Requirements.
u
A static IP address is assigned for the UNM2000 server.
u
The installation package of the UNM2000 is obtained.
u
The system firewall and anti-virus software are disabled.
1.
Double-click the UNM2000 installation software, and click Next in the displayed
Procedure
dialog box.
2.
Version: C
Select I accept the agreement and click Next.
39
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
3.
Select the Client and Server components and click Next.
Note: When installing the UNM2000 server end, you need to select the Client component; otherwise, the UNM2000 client end cannot be installed through Web.
40
Version: C
3 Installing the UNM2000
4.
Specify the UNM2000 installation path (the default installation path D: \unm2000 is recommended), and then click Next.
5. Version: C
Select English as the installation language and click Next. 41
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
6.
Set the Tomcat installation path (the default installation path D:\ApacheTomcat is recommended), and then click Next. If the ApacheTomcat has been installed on the computer,
42
➔
step 7.
Version: C
3 Installing the UNM2000
7.
Specify the server deployment mode. Select the default Centralized and click Next.
Note: This manual only introduces the single-instance installation mode (that is, deploying all services of the server end on the same computer) and therefore Centralized is selected.
8.
Specify the IP address of the computer running the server end, and then click Next.
Version: C
43
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
9.
10.
Select the database type and then click Next.
Configure the database parameter. 4 Set the MySQL parameter, set the database of the UNM2000 server end
according to Table 3-3 and then click Next. 44
Version: C
3 Installing the UNM2000
Table 3-3
Description of the MySQL Database Information
Item
Description
Host
Sets the IP address of the computer running the server end.
DataBase Password Confirm Password
Sets the password of the database. It should be consistent with the password typed upon database installation. Re-enter the password of the database super user. Sets the port of the database. It should be consistent with the
Port
port typed upon database installation.
4 Set the SQL Server parameter, set the database of the UNM2000 server
end according to Table 3-4 and then click Next. Table 3-4
Description of the SQL Server Database Information
Item
Description
Host
Sets the IP address of the computer running the server end.
DataBase Password Confirm Password Port
Version: C
Sets the password of the database. It should be consistent with the password typed upon database installation. Re-enter the password of the database super user. Sets the port of the database. It should be consistent with the port typed upon database installation.
45
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
Table 3-4
Description of the SQL Server Database Information (Continued)
Item
Description SQL Server instance name, which should be consistent with
SQL Server Instance
Note 1
that set during database installation. It is mssqlserver by default.
Note 1: This item appears only when the SQL server database is selected.
11.
46
Confirm the installation information and then click Next.
Version: C
3 Installing the UNM2000
12.
The installation of the program starts. In the alert box displayed a while later, click Finish.
13. Version: C
View the readme contents, and then click OK to close the readme file. 47
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
14.
Click No in the displayed alert box to not restart the computer immediately.
Note: Initialize the database table according to Initializing the Database Table and then start the computer.
3.1.5
Initializing the Database Table The following introduces how to initialize the database table architecture.
Prerequisite u
The UNM2000 software has been installed successfully.
u
The following services have been stopped: UnmBus, UNMCMAgent, UNMCMService, UnmNode and UnmServiceMonitor services.
Procedure 1.
Select Start
Run, and type cmd in the Open text box of the dialog box that
→
appears, as shown below:
48
Version: C
3 Installing the UNM2000
2.
Click OK to open the Command Line Interface (CLI) window and then execute the following commands.
C:\Users\Administrator> d: D:\> cd unm2000\server\tool D:\unm2000\server\tool> installdb.bat – i
3.
Complete the database initialization according to the GUI prompt.
Table 3-5 SN
Initialization Procedure Description Meaning
Description Select the database type
1
Select the database type.
sequence number according to the current database.
2
3
Enter the database file partition disk. Confirm to use D:\SQL_DATA as the database file path.
Default value.
Default value. Set this password according to the
4
Enter the database administrator
actual planning. The database
password.
password in this document is set to unm2K10. Set this password according to the
5
Re-enter the password.
actual planning. The database password in this document is set to unm2K10.
Version: C
6
Enter the database instance name.
Default value.
7
Enter the database port number.
Default value. 49
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
Table 3-5
Initialization Procedure Description (Continued)
SN
Meaning
Description
Enter the database login
8
Default value.
username.
9
Enter the database user password.
10
Select the database language.
Default value. u
1: Chinese environment
u
2: English Environment
Enter the name of the database file to be omitted when clearing the
11
database. Multiple files are
Default value.
separated by "-". 12
Confirm the files to be omitted.
Default value.
13
Select the database clearing type.
Default value.
4.
When the system returns Initial databases successful., initializing the database succeeded.
5.
3.1.6
Close the CLI window and restart the computer.
Checking Services The following introduces how to check the UNM2000 relevant services.
Procedure 1.
Select Start
2.
View the services listed in Table 3-6 and check whether the status of the
Administrative Tools
→
Services to open the Services window.
→
services is Started. If any service is not started, select the service and click Start Service to start it.
50
Version: C
3 Installing the UNM2000
Table 3-6
UNM2000 Relevant Services
No.
Name
Description
1
Apache Tomcat 6
It must be started.
2
UnmBus
It must be started.
UNMCMAgent
It must be started.
4
UNMCMService
It must be started.
5
UnmNode
It must be started.
6
UnmServiceMonitor
It must be started.
3
The MySQL database service, which must 7
MySQL
be started when the MySQL database is adopted. The relevant service of the SQL server
8
SQL Server (MSSQLSERVER)
database, which must be started when the SQL server database is adopted. The relevant service of the SQL server
9
SQL Server Browser
database, which must be started when the SQL server database is adopted. The relevant service of the SQL server
10
SQL Server VSS Writer
database, which must be started when the SQL server database is adopted. The relevant service of the SQL server
11
SQL Server Proxy (MSSQLSERVER)
database, which must be started when the SQL server database is adopted.
3.2
Installing the Client End The following introduces how to install the UNM2000 client end.
3.2.1
Installing the JRE The UNM2000 client must be installed and running with the Java software, and therefore you need to install the Java environment before installing the UNM2000 client.
Version: C
51
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
Context If the JRE has been installed on the computer running the UNM2000 client end, but its version does not meet the requirements described in Software Configuration Requirements, you need to uninstall it. See How to View the Java Version. u
If the operating system of the client end is Windows x86 (32-bit), please install the jre-6u38-windows-i586.exe.
u
If the operating system of the client end is Windows x64 (64-bit), please install the jre-6u38-windows-x64.exe.
Procedure 1.
Double-click the corresponding JRE installation package to open the dialog box as shown in the following figure.
2.
It is recommended to use the default destination folder and deselect the Change destination folder check box. Click Install and the installation process will be displayed.
52
Version: C
3 Installing the UNM2000
3.
Version: C
After the installation is completed, click Close.
53
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
3.2.2
Installing the Client End of the UNM2000 The following introduces how to install the online and offline UNM2000 client end. To install the online client and the offline client, you need first download the corresponding installation program from the server and then run the installation program on the local computer. The difference between the online client and the offline client lies in that the former requires entering the IP address and port of the server during installation while the latter does not require it. Upon running, the online client will automatically upgrade the UNM2000 version from the server, while the offline client upgrade it offline.
Prerequisite u
The JRE1.6.0 is installed.
u
The server end operates normally.
u
The communication between the server end and the client end is normal.
u
The system firewall and anti-virus software are disabled.
1.
Double-click the browser icon, type http://server end IP:port number/
Procedure
webstart/ (for example, http://10.78.11.225:8080/webstart/ ) in the browser address bar, and then press the Enter key to access the installation window of the UNM2000 client end.
Note: The port number indicates the Tomcat port number set during the installation of the server end.
54
Version: C
3 Installing the UNM2000
2.
Select the corresponding client and complete the client download and installation. 4 Download and install the online client.
a)
Click Online Client and click Save in the displayed dialog box as shown below.
b)
Double-click the online client program UNM2000_Client and click Next in the displayed dialog box.
Version: C
55
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
56
c)
Select I accept the agreement and click Next.
d)
Select the UNMClient component and click Next.
Version: C
3 Installing the UNM2000
e)
Specify the installation path of the UNM2000 client (the default installation path D:\unm2000client is recommended), and then click Next.
Version: C
57
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
f)
Select the installation language and click Next.
g)
Set the IP address and port of the Web publishing server and then click Next.
58
Version: C
3 Installing the UNM2000
h)
Click Next to start installing the online client.
4 Download and install the offline client.
a)
Click Offline Client and click Save in the displayed dialog box as shown below.
b)
Double-click the offline client program UNM2000_Zip and click Next in the displayed dialog box.
Version: C
59
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
60
c)
Select I accept the agreement and click Next.
d)
Select the UNMClient component and click Next.
Version: C
3 Installing the UNM2000
e)
Specify the installation path of the UNM2000 client (the default installation path D:\unm2000client is recommended), and then click Next.
Version: C
61
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
f)
3.
Click Next to start installing the offline client.
After the installation completes, double-click the client shortcut icon
. In
the displayed Log into UNM2000 dialog box, type the username and password (both are admin by default), and type the IP address of the corresponding server in Server . Then click Login.
62
Version: C
3 Installing the UNM2000
Note: If the UNM2000 can be logged in successfully, the server end and the client end are installed successfully.
Version: C
63
4
Upgrading the UNM2000 The following introduces how to upgrade the UNM2000. The UNM2000 supports automatic upgrading of the client end. Upon startup, the client end will check for updates and upgrade itself automatically, so as to synchronize the version of the client end with the server end.
Preparation for Upgrade Backing Up the Original Configuration Data Backing Up the Software Package Uninstalling the Current Version Installing the Upgrade Version Importing the Configuration Data Verifying the Upgrade of the Server End
64
Version: C
4 Upgrading the UNM2000
4.1
Preparation for Upgrade The preparations for upgrading the server end of the UNM2000 include the following aspects: u
The computer running the UNM2000 server end meets the system configuration requirements described in System Configuration Requirements.
4.2
u
The version number of the currently used UNM2000 is confirmed.
u
The installation package of the new version of the UNM2000 is obtained.
Backing Up the Original Configuration Data To avoid data loss caused by upgrading, it is necessary to back up the original configuration data before the upgrade.
Prerequisite The FTP server can be connected normally.
Procedure 1.
Double-click the browser icon, type http://server end IP:52302/nmtool/ in the browser address bar, and then press the Enter key to access the login GUI of the UNM2000 network management tool.
2.
Type the username and password on the login GUI (both are Admin by default), and click Login.
Version: C
65
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
3.
Click Import/Export to access the configuration import / export GUI, as shown below:
4.
Click Export and enter the IP address, port number, username and password of the FTP server in the displayed dialog box.
4.3
5.
Click OK.
6.
In the Export Success alert box that appears, click OK.
Backing Up the Software Package When the UNM2000 cannot work normally, you can restore it to the latest version using the backup software package.
Procedure 1.
Copy the unm2000-version number-windows-installer.exe files of both the new version and the current version to the D:\unm2000 install files directory. “
66
”
Version: C
4 Upgrading the UNM2000
Note: u
If the D:\unm2000 install files directory does not exist, create it and “
”
then back up the files. u
If the software package of the current version does not exist, back up the current installation folder of the current UNM2000, for example, D:\unm2000.
4.4
Uninstalling the Current Version After completing the backup, you can uninstall the current UNM2000 according to the following procedures.
Procedure You can uninstall the current version via the following three methods. u
Version: C
Method 1: 1)
Select Start
Control Panel to open the Control Panel window.
2)
Click Uninstall a program to open the Programs and Features window.
3)
Select UNM2000 and click Uninstall/Change.
4)
In the displayed Question alert box, click Yes to uninstall the UNM2000.
5)
Click OK in the displayed Info alert box.
→
67
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
6)
u
In the displayed Question alert box, click Yes to restart the computer.
Method 2: 1)
Access the UNM2000 installation directory (for example, D:\UNM2000) and double-click uninstall.exe.
68
2)
In the displayed Question alert box, click Yes to uninstall the UNM2000.
3)
Click OK in the displayed Info alert box.
Version: C
4 Upgrading the UNM2000
4)
u
Version: C
In the displayed Question alert box, click Yes to restart the computer.
Method 3: 1)
Select Start
Programs
2)
In the displayed Question alert box, click Yes to uninstall the UNM2000.
3)
Click OK in the displayed Info alert box.
4)
In the displayed Question alert box, click Yes to restart the computer.
→
UNM2000
→
Uninstall UNM2000.
→
69
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
Subsequent Operation After uninstalling the UNM2000 and restarting the UNM2000 server, you need to manually delete the unm2000 folder (D:\unm2000 by default) under the installation directory of the original UNM2000 version.
4.5
Installing the Upgrade Version The following introduces how to upgrade the UNM2000.
Prerequisite u
The UNM2000 of the original version is uninstalled.
u
The ANM2000 of the original version is uninstalled. The UNM2000 and ANM2000 cannot be installed on the same computer.
Procedure 1.
Install the UNM2000 software according to Installing the UNM2000 Software.
2.
Initialize the database table according to Initializing the Database Table and then start the computer.
3.
Check and start up the UNM2000 relevant services according to Checking Services.
70
Version: C
4 Upgrading the UNM2000
4.6
Importing the Configuration Data After completing the upgrade of the UNM2000 version, you need to import the configuration data.
Prerequisite u
The UNM2000 relevant services are started.
u
The UNM2000 can connect to the FTP server where the configuration data are saved.
Procedure 1.
Double-click the browser icon, type http://server end IP address: 52302/ nmtool/ in the address bar of the browser, and then press the Enter key to access the login GUI of the UNM2000 management tool.
2.
Type the username and password on the login GUI (The default values are both Admin), and click Login.
3.
Select all services on the process management GUI, click Stop, and then click OK in the displayed alert box.
4.
After the status of each service turns to Stopped, click Import/Export to access the configuration import / export GUI, as shown below:
Version: C
71
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
5.
Click Import, and click OK in the displayed Please close all network management services alert box.
6.
Enter the IP address, port number, username and password of the FTP server in the import dialog box.
Note: The default port of the FTP server is 21 . Please check and enter the correct port of the FTP server.
7.
Click OK.
8.
In the displayed Import Successful alert box, click OK.
9.
Click Process manage, select all services, and click Start to start all the services.
4.7
Verifying the Upgrade of the Server End The following introduces how to verify the upgrade of the server end.
Prerequisite The JAVA cache of the original client should be cleared. Follow the steps below to clear the JAVA cache. 1.
Run the javacpl.exe file in the C:\Program Files\Java\jre6\bin folder of the client to open the Java Control Panel dialog box.
72
Version: C
4 Upgrading the UNM2000
2.
In the Java Control Panel dialog box, click View next to Settings to open the Java Cache Viewer dialog box.
3.
Version: C
Select the application program and click
to delete the Java cache.
73
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
Procedure 1.
Double-click the browser icon, type http://server end IP:port number/ webstart/ (for example, http://10.78.11.225:8080/webstart/ ) in the browser address bar, and then press the Enter key to access the installation window of the UNM2000 client end.
Note: The port number indicates the Tomcat port number set during the installation of the server end.
2.
Click Online Client, and the following alert box appears, downloading, validating and installing the client end software.
74
Version: C
4 Upgrading the UNM2000
3.
In the displayed Log into UNM2000 dialog box, type the username and password (both are admin by default) and type the IP address of the corresponding server in Server . Then click OK.
Note: If users can log in the UNM2000 successfully, the upgrade of the server end is successful.
Version: C
75
5
FAQ The following introduces the FAQs in installing and uninstalling the UNM2000.
How to View the Installation / Uninstallation Logs How to View the Java Version How to Uninstall the MySQL Database How to Uninstall the Tomcat How to View the Occupation of System Ports
76
Version: C
5 FAQ
5.1
How to View the Installation / Uninstallation Logs
Problem If errors occur during the installation / uninstallation, how to view the installation / uninstallation logs?
Solution Do as follows:
5.2
1.
Access the UNM2000 installation directory (for example, D:\UNM2000).
2.
Open the install.log or uninstall.log file and view the recorded logs.
How to View the Java Version
Problem How to view the Java version?
Solution On the Windows OS, follow the steps below to view the Java version: 1.
Select Start
Run, and type cmd in the Open text box of the dialog box that
→
appears, as shown below:
2.
Click OK, and type java -version in the CLI window to view the version information.
Version: C
77
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
On the SUSE Linux OS, follow the steps below to view the Java version: 1.
Right-click the desktop and select Open in Terminal from the shortcut menu to open the Terminal window.
2.
5.3
Type java -version to view the version information.
How to Uninstall the MySQL Database
Problem How to uninstall the MySQL database?
Solution Do as follows: 1.
Stop the MySQL service. 1)
Select Start
Administrative Tools
→
Services to open the Service
→
window. 2) 2. 78
Right-click the MySQL service and select Stop.
Delete the MySQL service. Version: C
5 FAQ
1)
Select Start
Run, and type cmd in the Open text box of the dialog box
→
that appears, as shown below.
2)
Click OK to open the CLI window and then execute the following commands.
C:\Users\Administrator> d: D:\> cd unm2000db\mysql\bin D:\unm2000db\mysql\bin> mysqld.exe-remove
When Service successfully removed is displayed, the MySQL service has been deleted, as shown below.
Version: C
79
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
5.4
How to Uninstall the Tomcat
Problem How to uninstall the Tomcat?
Solution Do as follows: 1.
Select Start
Run, and type cmd in the Open text box of the dialog box that
→
appears, as shown below:
2.
Click OK to open the CLI window and then execute the following commands.
C:\Users\Administrator> d: D:\> cd ApacheTomcat\bin D:\ApacheTomcat\bin> service.bat remove
When The service ‘Tomcat6’ has been removed is displayed, the Tomcat service has been deleted, as shown below:
80
Version: C
5 FAQ
3.
5 .5
Dele Delete te the the D:\ApacheTomcat file D:\ApacheTomcat file folder.
How to View the Occupation Occupation of System System Ports Ports
Problem How to view the occupation of system ports?
Solution Do as follows: 1.
Select Start
Run, Run, and type cmd type cmd in in the Open the Open text text box of the dialog box that
→
appears, as shown below:
2.
Click OK, OK, and type netstat-nao type netstat-nao in in the CLI window to view the occupation of system ports.
Version: C
81
UNM2000 Network Convergence Management System (Based on Windows) Installation Guide
82
Version: C
Appen Appendi dix x A Abbre Abbrevi viat atio ions ns BML
Business Management Layer
BMS
Business Management System
CORBA
Architecture
CPU
Central Processing Unit
DCC
Data Communication Channel
DCN
Data Communication Network
DDN
Digital Data Network
EML
Element Management Layer
EMS
Element Management System
EPON
Ethernet Passive Optical Network
GPON
Gigabit-Capable Passive Optical Network
FTP
File Transfer Protocol
GE
Gigabit Ethernet
GNE
Gate Network Element
GUI
Graphic User Interface
IP
Internet Protocol
ITU-T
Version: C
Common Object Request Broker
International Telecommunication UnionTelecommunication Standardization Sector
NE
Network Element
NEL
Network Element Level
NML
Network Management Layer
NMS
Network Management System
OLT OLT
Optical Line Terminal
ONT
Optical Network Terminal
ONU
Optical Network Unit
SML
Service Management Layer
SMS
Service Management System
TCP
Transfer Control Protocol
TL1
Transaction Language 1
TMN
Telecommunications Management Network
UDP
User Datagram Protocol
UPS
Uninterrupted Power System
83
Product Documentation Customer Satisfaction Survey Thank you for reading and using the product documentation provided by FiberHome. Please take a moment to complete this survey. Your answers will help us to improve the documentation and better suit your needs. Your responses will be confidential and given serious consideration. The personal information requested is used for no other purposes than to respond to your feedback. Name Phone Number Email Address Company To help us better understand your needs, please focus your answers on a single documentation or a complete documentation set. Documentation Name Code and Version Usage of the product documentation: 1. How often do you use the documentation? □
□
Frequently
Rarely
□
Never
□
Other (please specify)
2. When do you use the documentation? □
in starting up a project
shooting
□
□
in installing the product
□
in daily maintenance
□
in trouble
Other (please specify)
3. What is the percentage of the operations on the product for which you can get instruction from the documentation? □ 4. Are
100%
□
□
50%
□
0%
□ Other
(please specify)
you satisfied with the promptness with which we update the documentation?
□ Satisfied 5. Which
□
80%
□ Unsatisfied
(your advice)
documentation form do you prefer?
Print edition
□
Electronic edition
□
Other (please specify)
Quality of the product documentation: 1. Is the information organized and presented clearly? □
Very
□
Somewhat
□
Not at all (your advice)
2. How do you like the language style of the documentation? □
Good
□
Normal
□
Poor (please specify)
3. Are any contents in the documentation inconsistent with the product?
View more...
Comments