USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book

When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.

FOR ANY QUERIES PLEASE RING THE IDEAL CONSUMER HELPLINE : 01482 498660 NOTE. BOILER RESET PROCEDURE To reset boiler, turn mode control knob to reset position and immediately turn knob back to required setting.

Introduction

Minimum Clearances

The Logic Combi is a wall mounted, room sealed, condensing combination boiler, featuring full sequence automatic spark ignition and fan assisted combustion.

Clearances of 165mm (6 1/2") above, 100mm (4") below, 2.5mm (1/8") at the sides and 450mm (17 3/4") at the front of the boiler casing must be allowed for servicing.

Due to the high efficiency of the boiler, condensate is produced from the flue gases and this is drained to a suitable disposal point through a plastic waste pipe at the base of the boiler. A condensate 'plume' will also be visible at the flue terminal.

Bottom clearance Bottom clearance after installation can be reduced to 5mm.

The Logic Combi is a combination boiler providing both central heating and instantaneous domestic hot water.

Safety Current Gas Safety (Installation & Use) Regulations or rules in force.

This must be obtained with an easily removable panel, to enable the consumer to view the system pressure gauge, and to provide the 100mm clearance required for servicing.

To light the boiler. Refer to Frame 1 If a programmer is fitted refer to separate instructions for the programmer before continuing.

1. In your own interest, and that of safety, it is the law that this boiler must be installed by a Gas Safe Registered Engineer, in accordance 2. with the above regulations. 3. In IE, the installation must be carried out by a Registered Gas

CHECK THAT THE ELECTRICITY SUPPLY TO BOILER IS OFF. Set the mains mode knob control (D) to ‘Off’. Set the Domestic Hot Water temperature control (B) and Central Heating temperature control (C) to ‘max’.

Installer (RGII) and installed in accordance with the current edition of 4. Set the preheat control (A) to ‘on’. I.S. 813 “Domestic Gas Installations”, the current Building Regulations and reference should be made to the current ETCI 5. Ensure that all hot water taps are turned off. rules for electrical installation. 6. Switch ON electricity to the boiler and check that all It is essential that the instructions in this booklet are strictly followed, external controls, e.g. programmer and room thermostat, are ON. for safe and economical operation of the boiler.

Electricity Supply

7. Set the mode knob control to winter (

).

Supply: 230 V ~ 50 Hz. The fusing should be 3A.

The boiler will commence the ignition sequence, first supplying heat to preheat the domestic hot water and then to the central heating, if required.

Important Notes

Note. In normal operation the boiler status display (E) will show codes:

This appliance must be earthed.

z This appliance must not be operated without the casing correctly fitted and forming an adequate seal.

Standby - no demand for heat.

z If the boiler is installed in a compartment then the compartment MUST NOT be used for storage purposes.

CH being supplied.

z If it is known or suspected that a fault exists on the boiler then it MUST NOT BE USED until the fault has been corrected by a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII).

DHW preheat.

z Under NO circumstances should any of the sealed components on this appliance be used incorrectly or tampered with. z This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instructions concerning use of the appliance by a person responsible for their safety. z Children should be supervised to ensure that they do not play with the appliance. In cases of repeated or continuous shutdown a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII) should be called to investigate and rectify the condition causing this and carry out an operational test. Only the manufacturers original parts should be used for replacement.

DHW being supplied.

Boiler frost protection - boiler will fire if temperature is below 5 degrees C. During normal operation the burner on indicator (F) will remain illuminated when the burner is lit. Note: If the boiler fails to light after five attempts the fault code will be displayed. RESET PROCEDURE To reset boiler, turn the mode control knob (D) to reset position and immediately turn knob back to required setting. The boiler will repeat the ignition sequence. If the boiler still fails to light consult a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII).

All Gas Safe Register installers carry a Gas Safe Register ID card, and have a registration number. Both should be recorded in the Benchmark Commissioning Checklist. You can check your installer by calling Gas Safe Register direct on 0800 4085500. Ideal Stelrad Group is a member of the Benchmark scheme and fully supports the aims of the programme. Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency. THE BENCHMARK SERVICE INTERVAL RECORD MUST BE COMPLETED AFTER EACH SERVICE

2

Ideal Logic Combi - User’s

Due to system variations and seasonal temperature fluctuations DHW flow rates/temperature rise will vary, requiring adjustment at the draw off tap : the lower the rate the higher the temperature, and vice versa.

Operation Winter conditions - i.e. CH and DHW required. Ensure the mode knob control (D) is set to winter (

)

The boiler will fire and supply heat to the radiators but will give priority to DHW on demand. The DHW preheat will operate as described under 'Summer conditions' during periods when there is no call for CH.

The boiler controls the central heating radiator temperature to a maximum of 80oC, adjustable via the CH temperature control (C). The Logic Combi is a high efficiency combination boiler which is most efficient when operating in condensing mode.

Summer conditions - i.e. DHW only required. Set the mode knob control to Summer (

Central Heating

).

The boiler will operate in this mode if the CH temperature control (C) is set to the ‘e’ position (economy mode). This control should be set to maximum for very cold periods

Set the CH external controls to OFF. Preheat will operate with the preheat switch (A) set to ON. The boiler will fire periodically for a few seconds to maintain the DHW calorifier in a preheated condition. The average time period between firing is 90 minutes. This may vary considerably due to the surrounding ambient temperature of the boiler. The boiler will fire whenever there is a demand for DHW.

To shut down the boiler

The boiler preheat facility can be immobilised by turning the preheat switch (A) to OFF. This will stop the boiler operating for short periods. This facility is primarily provided for boiler installations in a sensitive area (i.e. bedroom etc.)

Frost protection

Note. The pump will operate briefly as a self-check once every 24 hours, regardless of system demand.

Control of water temperature Domestic Hot Water The DHW temperature is limited by the boiler controls to 64oC maximum at low draw-off rate, adjustable via the DHW temperature control (B). Approx. flow temperatures for the boiler thermostat settings are:

Set the mode knob control to OFF

To relight the boiler Repeat the procedure detailed in 'To light the boiler'.

If no system frost protection is provided and frost is likely during a short absence from home, leave the heating controls (if fitted) at a reduced temperature setting. For longer periods, the entire system should be drained. If the system includes a frost thermostat then, during cold weather, the boiler should be turned OFF at the time switch (if fitted) ONLY. The mains supply should be left switched ON, with the boiler thermostat left in the normal running position.

Boiler Overheat Protection The boiler controls will shut down the boiler in the event of overheating. Should this occur, a fault code will be displayed. Refer to fault chart.

Knob Setting

Flow Temperature

Minimum

40o C (104o F)

Flame Failure

Maximum

64o C (147o F)

Should this occur a fault code chart.

will be displayed. Refer to fault continued . . . . . .

1

BOILER CONTROLS Legend A. Pre-heat On/Off

D. Mode Control

G. Pressure Gauge

B. DHW Temperature Control

E. Boiler Status

H. Condensate Drain

C. CH Temperature Control

F. Burner ‘on’ Indicator

J. Economy Mode

A

B

E

F

C

J

D

H G Ideal Logic Combi - User’s

3

Loss of system water pressure

Condensate Drain

The gauge (G) indicates the central heating system pressure. If the pressure is seen to fall below the original installation pressure of 1-2 bar over a period of time then a water leak may be indicated. In this event conduct the re-pressurising procedure as shown below. If unable to do so or if the pressure continues to drop a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII) should be consulted.

The condensate drain (H) must not be modified or blocked. Blockage of the condensate drain, caused by debris or freezing, can cause automatic shutdown of the boiler. If freezing is suspected and the pipe run is accessible an attempt may be made to free the obstruction by pouring hot water over the exposed pipe and clearing any blockage from the end of the pipe. If this fails to remedy the problem the assistance of a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII) should be sought.

THE BOILER WILL NOT OPERATE IF THE PRESSURE HAS REDUCED TO LESS THAN 0.3 BAR UNDER THIS CONDITION. 1. Ensure filling loop isolation valves are closed. 2. Remove the left hand cap.

Escape of gas

3. Attach on the filling loop. 4. Turn the filling loop isolation valves to the open position. The system will now fill.

Should a gas leak or fault be suspected contact the National Gas Emergency Service without delay. Telephone 0800 111 999

5. Wait for pressure gauge to reach 1 to 1.5 bar.

Do NOT search for gas leaks with a naked flame.

6. Close the filling loop isolation valves.

Cleaning

7. Disconnect the filling loop at left hand side and angle upwards.

For normal cleaning simply dust with a dry cloth. To remove stubborn marks and stains, wipe with a damp cloth and finish off with a dry cloth.

8. Replace cap.

DO NOT use abrasive cleaning materials.

Maintenance The appliance should be serviced at least once a year by a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII).

1 CLOSED

POSITION

5 3 4 OPEN POSITION PRESSURE GAUGE

2

7 8

6 CLOSED

POSITION

continued . . . . . . 3G9866

4

Ideal Logic Combi - User’s

POINTS FOR THE BOILER USER Note. In line with our current warranty policy we would ask that you check through the following guide to identify any problems external to the boiler prior to requesting a service engineers visit. Should the problem be found to be other than with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is not gained by the engineer.

TROUBLESHOOTING

NO HOT WATER

NO CENTRAL HEATING

Check the mains switch (fused spur) is turned on and ensure switch mode control knob (D) is in the summer or winter position

Check the mains switch (fused spur) is turned on and ensure switch mode control knob (D) is in the winter position

Is water coming out of the hot water tap when turned on?

NO

NO HOT WATER OR CENTRAL HEATING

Check the fused spur is turned on and ensure switch mode control knob (D) is in the winter position

Check the programmer (internal or external to the boiler) is in an “ON” position and the room thermostat is turned up

Does the boiler have a display showing on the front control panel?

YES See boiler “Fault Codes” section. If ‘0’ is displayed then contact Ideal Customer Services Helpline if your appliance is under warranty or a Gas Safe Registered Engineer, in IE a Registered Gas Installer (RGII), if out of warranty

Contact a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII)

NO

YES Does the boiler operate and provide central heating?

NO

See boiler “Operation Modes” and “Fault Codes” section

YES Check the time settings on the programmer are as you require and adjust if necessary

Contact a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII)

See boiler “Operation Modes” and “Fault Codes” section. If “0” is displayed then contact a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII)

continued . . . . . .

Ideal Logic Combi - User’s

5

OPERATION MODES DISPLAY CODE ON BOILER

DESCRIPTION The boiler is in standby mode awaiting either a central heating call or hot water demand.

The boiler has a call for central heating but the appliance has reached the desired temperature set on the boiler.

The boiler has a call for hot water but the appliance has reached the desired temperature set on the boiler.

The boiler is operating in central heating mode.

The boiler is operating in hot water mode.

The boiler is operating in pre heat mode.

The boiler is operating in frost mode.

continued . . . . . .

6

Ideal Logic Combi - User’s

FAULT CODES DISPLAY CODE ON BOILER

DESCRIPTION

ACTION

Outside Sensor Failure

Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

Low Mains Voltage

Contact a qualified electrician or your electricty provider.

Unconfigured PCB

Unconfigured PCB. Please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

No Water Flow Thermistor

Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

5 Boiler Resets in 15 minutes 1. Turn power off and on at the fused spur. 2. If the boiler fails to operate please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

False Flame Lockout

Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

BCC Activation Fault

Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

BCC Fault

Low Water Pressure

Check system pressure is between 1 & 1.5bar on the pressure gauge. If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

Flow Temperature Overheat

No Water Flow

Flame Loss

1. Check other gas appliances in the house are working to confirm a supply is present in the property. 2. If other appliances do not work or there are no other appliances, check the gas supply is on at the meter and/or pre payment meter has credit. If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

Ideal Logic Combi - User’s

Fan Fault

Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

Flow Thermistor

Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

Return Thermistor

Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

7

Ideal Consumer Helpline Tel: 01482 498660 www.idealheating.com

Ideal Stelrad Group pursues a policy of continuing improvement in the design and performance of its products. The right is therefore reserved to vary specification without notice.

Ideal, P.O. Box 103, National Ave, Kingston Upon Hull, HU5 4JN. Tel. 01482 492251 Fax. 01482 448858. Registration No. London 322 137.