SCE TEMPLATES PACiS Technical Training Level 2 CS&P – Support Team

PCL

• Content  Template Creation  Template Instantiation  Template Facilities

Schneider Electric - CS&P – SCE Templates – E01

2

• Content  Template Creation  Template Instantiation  Template Facilities

Schneider Electric - CS&P – SCE Templates – E01

3

• Reminder 1) Reminder  Template : why ? - Business oriented data modelling - Speed-up configuration process - Attributes protection - Libraries

2) Template creation  Several ways - Import from 2nd database / Library - From scratch

Schneider Electric - CS&P – SCE Templates – E01

4

• Import Template from 2nd database Import from Second DB of Libraries, Other Business

1°Open the 2nd File 2°In Template List 2nd Data Base appears 3°Select Template 2nd DB 4°Add Selected Template from 2nd DB To Main “Current” DB 5°Template has been imported in current DB 6°Close the 2nd File Schneider Electric - CS&P – SCE Templates – E01

5

• Create Template from scratch (1) Template from scratch

Switch into Template mode

Right-click on Templates Select New

Schneider Electric - CS&P – SCE Templates – E01

6

• Create Template from scratch (2) Template from scratch 1°Select the New Template Empty

2°Choose hierarchy to which this entry point is belonging to. 3°Choose main object = ENTRY POINT 4°Through “Object entry” window, add this object

Schneider Electric - CS&P – SCE Templates – E01

7

• Create Template from scratch (3) Template from scratch Template Entry Point = ANCHOR Through “Object entry” window, add objects in the template (in the 3 hierarchies) to complete the model

Template Content

One template can be instantiated in one template (= 2nd level of template) Up to 2 levels Schneider Electric - CS&P – SCE Templates – E01

8

• Content  Template Creation  Template Instantiation  Template Facilities

Schneider Electric - CS&P – SCE Templates – E01

9

• Instantiate Template (1) In Object DB using Templates Entry Window 1°Switch in Object Mode 2°Select the Father

LIST of Template candidates =>to be instantiated =>For this selected Father is refreshed

3°Select the template 4°Click “Add”

Schneider Electric - CS&P – SCE Templates – E01

10

• Instantiate Template (2) Check Instantiated Template

pictorial representation

ICON Template ANCHOR Name of instance + name of template

Temporary Graphic, Scs, Site Sub-part of the template need to be MOVED to appropriate Father (Next Slide)

ICON Template Sub-Part Attached template Schneider Electric - CS&P – SCE Templates – E01

11

• Instantiate Template (3) Moving attached template Part

Move or Cut/Paste - one by one - several via Contents of 1°Multi click with Shift/Ctrl key to select several parts 2°Cut

3°Select Father for 2nd part (Graphic) 4°Paste Schneider Electric - CS&P – SCE Templates – E01

12

• Template : Resume One Template may have Electric Part System Part Graphic Part

Template is Defined by ANCHOR position name in Template List

Template instance in Object DB Temporary Electric Part Temporary System Part Temporary Graphic Part

ANCHOR instance Sub part of template

Directly Placed

Schneider Electric - CS&P – SCE Templates – E01

To Move

13

• Check a Template instance (1) View Instances of one Template

in Object Mode 1°Right Click on template 2°Popup all instances REM: Reach Button when instance selected

3°Selecting the ANCHOR object

Schneider Electric - CS&P – SCE Templates – E01

14

• Check a Template instance (2) View Instance of one Template part

in Object Mode Instance of Sub part of template 1°View template content

Gives all template instance components, include ANCHOR, and template father

Schneider Electric - CS&P – SCE Templates – E01

15

• Content  Template Creation  Template Instantiation  Template Facilities

Schneider Electric - CS&P – SCE Templates – E01

16

• DOF : Degree Of Freedom Attributes Protection By default, attributes are protected => No possibility to change in Object Mode

To allow attributes modification => Define DOF in Template Mode

Appears in blue Schneider Electric - CS&P – SCE Templates – E01

17

• Parameters (1) Common value in DOF attributes Example : Graphical template for switching device representation => a lot of objects have to take the same colour => voltage level colour => Common value in DOF => Parameter 1°Template Mode 2°At ANCHOR level => Parameter tab

3°Create a Parameter : right click, New

Schneider Electric - CS&P – SCE Templates – E01

18

• Parameters (2) Common value in DOF attributes Associate a DOF attribute to a parameter DOF attribute : 1°Associate Parameter 2°Choose Parameter

Schneider Electric - CS&P – SCE Templates – E01

19

• Parameters (3) Common value in DOF attributes View all DOF attributes associated to a parameter 1°Right-Click on Parameter : 2°View linked attributes

Linked attributes

Schneider Electric - CS&P – SCE Templates – E01