KNPC SWP Best Work Permit Issuer and Executor Schemes Rev.1
Short Description
KNPC SAFE WORK PRACTICE...
Description
PRINTED COPY IS NOT CONTROLLED
PRINTED COPY IS NOT CONTROLLED
HEALTH, SAFETY & ENVIRONMENT DEPT. BEST WORK PERMIT ISSUER & EXECUTOR SCHEMES TABLE OF CONTENTS Page 1.0
Scope & Coverage
3
2.0
Criteria
3
3.0
Guidelines
4
4.0
Award & Recognition
4
5.0
Evaluation Check Lists (Annexure – I )
5
6.0
Performance Standard
12
BEST WOK PERMIT ISSUER & EXECUTOR SCHEME
Page 2 of 12
PRINTED COPY IS NOT CONTROLLED
Best Work Permit Issuer & Executor Scheme Guidelines 1.0 SCOPE & COVERAGE: The importance of promoting and maintaining interest in Health, Safety & Environment (HSE) awareness amongst employees is the prime objective of KNPC management. At various stages, the management has been demonstrating its commitment and support to ensure successful promotional activities towards improved HSE awareness among employees. With this in mind, a new HSE promotional schemes “HSE Best Work Permit Issuer & Executor Scheme” has been developed. All work permit issuers and executors of the various KNPC sites issuing or receiving work permits on daily basis in process unit areas / facilities covering running units and shutdown activities including non process areas i.e. labs, ware house building etc are entitled for the scheme.. There will be a quarterly selection of One Best Work Permit Issuer and One Best Work Permit Executor among all competing issuers and executors of KNPC as well as contractors supervisors, who have a valid Work Permit Authorization card for any KNPC site.
2.0 CRITERIA: Site evaluation of five ( 5 ) issued or received work permits per quarter for each issuer and executor will be done as per Evaluation Check lists “Annexure – I”. Evaluation of the work permits will be carried out by Assigned Safety Engineer. Three months will be the evaluation period for the quarterly selection of the winner. Preferably random evaluation of two ( 2 ) cold permits, two ( 2 ) hot work permits and one ( 1 ) confined space entry permit. ( i.e. total five permits ) will be carried out. Preferably only critical work defined in section 6.0 of document “Safe Work Practices of Work Permit System & Risk assessment” shall be considered for evaluation. However non critical cold work permits should be evaluated if no other permits are available.
3.0 GUIDELINES: Team Leader S&F will select one or more divisions from various operation and service groups to be considered for the scheme for each quarter and prepare yearly schedule as per site conditions. The schedule should cover all operations and service
BEST WOK PERMIT ISSUER & EXECUTOR SCHEME
Page 3 of 12
PRINTED COPY IS NOT CONTROLLED
groups/divisions at site during the fiscal year. In PD, Team Leader Safety (Project) shall decide which PD divisions are to be considered for evaluation. Similarly, in LM, Team Leader S & F will decide the same. This is a quarterly based scheme. There will be four winners as “Best Work Permit Issuers and four winners as “Best Work Permit Executors” in one fiscal year at each site. There is another option. If the Team Leader S&F feels that issuers and executors will lose interest, once their quarter of evaluation is over, he can extend evaluation period as one year to maintain the same level of compliance throughout the year. But only Four Best Issuers and Four Best Executors can be awarded on yearly basis. Assigned Safety Engineer should select five work permits at random basis for each Work Permit Issuer and Executor. All these five permits selected must be issued on different dates of the period. He will visit the work site and do the evaluation as per Annexure –I. The check lists in Annexure – I, have been made exactly similar to checklists of “On Line Work Permit Audit” so that Safety Engineer can utilize them for this purpose also. Only relevant items of the checklists will be filled for evaluation of the permits. Assigned Safety Engineer will submit completed evaluation check list for all selected Issuers and Executors to Sr. Safety Engineer, who in turn will decide “Best Work Permit Issuer and Executor” with the consent of Team Leader Safety & Fire. In case of tie, Team Leader of Safety Div. will decide the final winners.
4.0 AWARD & RECOGNITION Team Leader Safety & Fire will announce the quarterly “Best Work Permit Issuer and Executor” results in Operations or any suitable meeting and award a token gift to the winner.
BEST WOK PERMIT ISSUER & EXECUTOR SCHEME
Page 4 of 12
PRINTED COPY IS NOT CONTROLLED
ANNEXURE – I KUWAIT NATIONAL PETROLEUM COMPANY (MAA/MAB/SHU/LM) WORK PERMIT & COMPLIANCE AUDIT CHECK LIST FOR COLD WORK PERMIT From
: ___________________________ Date : _______________
To
: TL. Safety & Fire-MAA/MAB/SHU/LM
Description of Work being performed: Is Work Permit Available at site:
Yes/No
Audit Location (Area/Unit):
W.P. No. : Date / Time:
Name & Emp. No. of Issuing Authority: Name & Emp. No. of Executing Authority: Legend: 1. Meeting Requirements 2. Not Meeting Requirements (Tick mark whichever is applicable and write ‘NA’ for Not Applicable)
Sr.#
Item Description
Compliance by Issuing Authority
1 1A 1B 1C 2 3A 3A-1 3A-2 3A-3 3A-4
3A-5 3A-6 3A-7 3A-8
Is Location correct? Does Description of work match with work being performed? Is ‘Issued to’ written correctly? Does ‘Work Criticality’ match? Equipment Isolation & Preparation Isolation from power, steam, air, liquid & gases Depressurized/drained Blanked/blinded/disconnected If blinded, whether approved blind list tags & equipment sketch available at location Water flushing, steaming, venting carried out Ventilated/cooled Continuous inert gas flow arranged (Applicable for Inert Entry) Inspection Approval obtained (If applicable)
2
Compliance by Executing Authority
1
2
NA
NA
NA NA
NA NA
NA
NA
Auditor’s Remarks
BEST WOK PERMIT ISSUER & EXECUTOR SCHEME
Page 5 of 12
PRINTED COPY IS NOT CONTROLLED
Sr.#
Item Description
3B
Residual hazards ticked properly
3C
PROTECTION MEASURES
3C-1
Hand protection
3C-2
Ear protection
3C-3
Eye/Face protection
3C-4
Protective clothing
3C-5
Respiratory protection
3C-6
Fall protection
3C-7
Availability of Appropriate Gas Detectors including personal monitors
3C-8
Is adequate supervision available on site?
4A
Compliance by Issuing Authority 1 2
Compliance by Executing Authority 1 2 NA
NA
GAS TEST
4A-1
Frequency of Gas testing marked appropriately
NA
NA
4A-2
Gas test results entered as applicable.
NA
NA
4A-3
Gas testers details/authorization
NA
NA
4B 4B-1 4B-2 5
ELECTRICAL ISOLATION Type of isolation marked appropriate Is Multi lock system followed? AUTHORIZATION
5.1
Appropriate & complete
6
GENERAL REMARKS
6.1 6.2
Auditor’s Remarks
Tools, Equipment, Barricading, Housekeeping, Fire Ext.,Scaffolding, etc., as per requirement Are Associated permits mentioned available and valid? REMARKS:________________________________________________________________________ __________________________________________________________________________________ Audited by:-
Name: ____________________________ Emp. No.: _______________ Designation: _______________________ Signature:________________
Safety Engineer: _____________________________ Copy: Team Leader. of W.P. Issuing Authority Team Leader of W.P. Executing Authority File.
BEST WOK PERMIT ISSUER & EXECUTOR SCHEME
Page 6 of 12
PRINTED COPY IS NOT CONTROLLED
From
KUWAIT NATIONAL PETROLEUM COMPANY (MAA/MAB/SHU/LM) WORK PERMIT & COMPLIANCE AUDIT CHECK LIST FOR HOT WORK PERMIT : ___________________________ Date : _______________
To
:
Description of Work being performed: Is Work Permit Available at site:
W.P. No. :
Audit Location (Area/Unit):
Date / Time:
Name & Emp. No. of Issuing Authority: Name & Emp. No. of Executing Authority: Legend: 1. Meeting Requirements 2. Not Meeting Requirements (Tick mark whichever is applicable and write ‘NA’ for Not Applicable) Sr.No.
Item Description
1A
Is Location correct?
1B
Does description of work match with work being performed?
1C
Is ‘Issued to’ written correctly?
2
Does ‘Work Criticality’ match?
3A
Compliance by Issuing Authority 1 2
Compliance by Executing Authority 1 2
Equipment Isolation & Preparation
3A-1
Isolation from power, steam, air, liquid, gases
NA
NA
3A-2
Depressurized/drained
NA
NA
3A-3
Blanked/blinded/disconnected
NA
NA
3A-4
If blinded, whether approved blind list, tags & equipment sketch available at location
3A-5
Water flushing, steaming, venting carried out
NA
NA
3A-6
Ventilated/cooled
3A-7
Sewers & drains covered
3A-8
Combustibles removed from area
3A-9
Continuous inert gas flow arranged (Applicable for Inert Entry)
3A-10
Inspection Approval obtained
3A-11 3B
Auditor’s Remarks
Vehicles/Equipment condition Expected residual hazards marked properly
NA
NA
BEST WOK PERMIT ISSUER & EXECUTOR SCHEME
Page 7 of 12
PRINTED COPY IS NOT CONTROLLED
Sr.No.
3C
Item Description
Hand protection
3C-2
Ear protection
3C-3
Eye/Face protection
3C-4
Protective clothing
3C-5
Respiratory protection
3C-6
Fall Protection
3C-7
Equipment grounding protection
3C-8
Fire Fighting Eqpt./Water hose/Fire Watch
3C-9
Availability of Appropriate Gas Monitors
3C-10
Availability of Fire Retardant tarpaulin
4A
4A-2
Frequency of Gas testing marked appropriately Gas test result entered as applicable.
4A-3
Gas testers details/authorization
4B
NA
NA
NA
NA
NA
NA
NA
NA
ELECTRICAL ISOLATION
4B-1 4B-2
Type of isolation marked appropriate Multi-lock system applied & followed AUTHORIZATION
5.1
Authorization appropriate & complete
6
GENERAL REMARKS Tools, Equipment, Housekeeping, Scaffolding, etc., as per requirement Associated permits and authorizations present, appropriate and valid.
6.2
Auditor’s Remarks
GAS TEST
4A-1
6.1
Compliance by Executing Authority 1 2
PROTECTION MEASURES
3C-1
5
Compliance by Issuing Authority 1 2
REMARKS:___________________________________________________________________ Audited by:-
Name: ___________________ Emp. No.: __________
Designation: _______________________ Signature:________________ Safety Engineer:-____________________________ Copy: Team Leader of W.P. Issuing Authority Team Leader. of W.P. Executing Authority File.
BEST WOK PERMIT ISSUER & EXECUTOR SCHEME
Page 8 of 12
PRINTED COPY IS NOT CONTROLLED
From
KUWAIT NATIONAL PETROLEUM COMPANY (MAA/MAB/SHU/LM) WORK PERMIT & COMPLIANCE AUDIT CHECK LIST FOR CONFINED SPACE ENTRY : ___________________________ Date : _______________
To
: TL. Safety & Fire-MAA/MAB/SHU/LM
Type of confined space entry: Is Confined Space Entry Authorization Available at site:
Yes / No
C.S.E A. No. : Date / Time:
Audit Location (Area/Unit): Name & Emp. No. of Issuing Authority: Name & Emp. No. of Executing Authority:
Legend: 1. Meeting Requirements 2. Not Meeting Requirements (Tick mark whichever is applicable and write ‘NA’ for Not Applicable) Sr. No.
Item Description
Compliance by Issuing Authority 1
1A
Is Location correct?
1B
Is ‘Issued to’ written correctly?
2
Does ‘Entry Criticality’ match?
3A
2
Compliance by Executing Authority 1 2
Equipment Isolation & Preparation
3A-1
Isolation from power, steam, air, liquid & gases
NA
NA
3A-2
Depressurized/drained
NA
NA
3A-3
Is equipment positively isolated
NA
NA
3A-4
If blinded, whether approved blind list, tags and equipment sketch available at location.
3A-5
Water flushing, steaming, venting carried out
NA
NA
NA
NA
3A-6 3A-7 3A-8
Auditor’s Remarks
Is equipment ventilated/cooled Are adequate number of man-ways open & clear Continuous inert gas flow arranged (Applicable only for inert entry)
3A-9
Is illumination adequate and proper
3B
Expected residual hazards marked appropriately
3C
PROTECTION MEASURES
3C-1
Hand protection
3C-2
Ear protection
3C-3
Eye/Face Protection
BEST WOK PERMIT ISSUER & EXECUTOR SCHEME
Page 9 of 12
PRINTED COPY IS NOT CONTROLLED
Sr. No.
Item Description
Compliance by Issuing Authority 1
2
Compliance by Executing Authority 1 2
3C-4
Protective clothing
3C-5
Respiratory protection
3C-6
3C-12
Availability of Appropriate Gas monitors Grounding protection for air eductor, blower, A/C Authorized identifiable attendant with SCBA and his details available Is rescue equipment / pre-plan available Is maximum number of personnel who are authorized to enter specified Is safety harness/life line and communication equipment available Is entry board available and displayed
3C-13
Is attendance sheet available
4A 4A-1
GAS TEST Frequency of Gas testing marked appropriately
NA
NA
4A-2
Gas test result entered as applicable.
NA
NA
4A-3
Gas testers details/authorization
NA
NA
4B 4B-1
ELECTRICAL ISOLATION NA
NA
3C-7 3C-8 3C-9 3C-10 3C-11
4B-2 5 5.1 6 6.1 6.2 6.3 6.4
Type of isolation marked appropriate Is Multi-lock system followed
Auditor’s Remarks
AUTHORIZATION Appropriate & complete
GENERAL REMARKS Tools, Equipment, Housekeeping, Scaffolding, etc., as per requirement Are associated permits and authorizations mentioned, available and valid Are other measures, like barricades, fire protection equipment available Is adequate supervision available
REMARKS:__________________________________________________________ ____________________________________________________________________ Audited by:Name: ___________________ Emp. No.: __________ Designation: _______________________ Signature:________________ Safety Engineer: _______________________________ Copy:
Team Leader of W.P. Issuing Authority Team Leader. of W.P. Executing Authority File.
BEST WOK PERMIT ISSUER & EXECUTOR SCHEME
Page 10 of 12
PRINTED COPY IS NOT CONTROLLED
KUWAIT NATIONAL PETROLEUM COMPANY WORK PERMIT & COMPLIANCE AUDIT CHECK LIST FOR WORK PERMIT CLOSURE ( SEC. : 6 )
HOT WORK COLD WORK CSE PERMIT From :_Safety Engr. Area :______ TL. Safety & Fire – MAA To :
Date :____-____-_
Description of Work being performed Permit Ser. No. : 2006
Audit Location :
Date :
-
-
Name & Emp. No. of Issuing Authority Name & Emp. No. of Executing Authority Legend : 1. Meeting Requirement (or N/A) Sec. No.
Item Description
2. Not Meeting Requirements
Compliance by issuing Authority 1
2
Work Completed
N/A
N/A
Site Handed Over in Safe Condition
N/A
N/A
House Keeping
N/A
N/A
Ensured all Men have come out Man ways barricade / “No Entry” Sign Displayed Multi Lock Removed
N/A
N/A
N/A
N/A
N/A
N/A
Executor Closure
N/A
N/A
Compliance by Executing Authority 1
2
Site Checked & Found Safe
N/A
N/A
Field Operator Closure
N/A
N/A
Issuer Closure
N/A
N/A
Auditor’s Remarks
Work Permit filed 6A
6B
AUDITED BY :
NAME _________________________ SIGN _________________________ EMPNO__________
Copy : Team Leader of WP Issuing Authority – Team Leader of WP Executor Authority— BEST WOK PERMIT ISSUER & EXECUTOR SCHEME
Page 11 of 12
PRINTED COPY IS NOT CONTROLLED
PERFORMANCE STANDARD Best Work Permit Issuer & Executor Scheme TITLE
BEST WORK PERMIT ISSUER & EXECUTOR SCHEME
WHAT
To encourage all work permit issuers and executors to understand and comply with work permits conditions correctly with full attention.
WHO
All supervisors / designated persons having a valid work permit issuer or executor card can participate in the scheme
WHEN
WHERE
HOW
Once in three months.
At all KNPC sites • •
• • •
• AWARD AND RECOGNIT ION
• •
Area/Assigned Safety Engineer will visit the permit work area sites. He will at random select two ( 2 ) cold work permit sites, two ( 2 ) hot work permit sites and one ( 1 ) confined space entry permit site. ( total five permit sites ) on different dates as per schedule. He will evaluate the work permit sites as per ANNEXURE – I EVALUATION CHECK LISTS. He will submit completed evaluation check lists of selected work permit sites to Senior Safety Engineer. Senior Safety Engineer will select the winner as per above check lists with the consent of Team Leader Safety Division at site. In case of tie, Team Leader of Safety Div. will decide the final winners. Team Leader will announce and award the winner with a token gift in operation meeting. A maximum of four (4) best work permit executors and maximum of four (4) best work permit issuers per budget year A token gift and a certificate of each winner.
BUDGET
HSE promotion budget
OWNER
Manager HSE
BEST WOK PERMIT ISSUER & EXECUTOR SCHEME
Page 12 of 12