Axial Load = P1 = Moment along Major axis = Mx = Moment along Minor axis = Mz =
65.2 T 0.32 T-m -6.0341 T-m G.L
COLUMN DETAILS :
Length = ( Larger Dimension of Column ) Width = ( Smaller Dimension of Column )
0.45 m 0.23 m
FOOTING DETAILS :
Length = L = Width = B = Depth = D =
1.5 m 1.5 m 0.35 m
Cover to Main R/f = Diameter of R/f in Footing =
0.05 m 12 mm
1.2
0.4 SOIL DETAILS :
Density of Soil = g = Depth of foundation below G.L = H =
3 1.7 T/m 1.5 m
1.50 X
MATERIAL CONSTANT :
M - 25 N/mm2 Fe - 415 N/mm2 1.5
Concrete Grade = R/f Grade = Load Factor = gf =
1.50 Z
Z
DESIGN FORCES :
Axial load = P = Self Weight of Footing =
65.20 T 1.97 T
X
1.50
Total Vertical Load =
67.17 T
Moment along Major axis Moment along Minor axis
0.3182 T-m -6.0341 T-m
PRESSURE CALCULATION :
SBC = 20 T/m2 1.25 x FOR EARTHQUAKE CONDITION ALLOWABLE S.B.C =
P=
P A
+ -
Mx Zx
+ -
\ Pmax =
29.85 +
0.57 +
-10.727 =
19.69
T/m2
\ Pmin =
29.85 -
0.57 -
-10.727 =
40.01
T/m2
20 =
25 T/m2
Mz Zz
< S.B.C
SAFE
TENSION NOT CREATED
R/F CALCULATION FROM BENDING CONSIDERATION :
1500
635
1500
230 450 525
40.0 T/M2
19.7 T/M2
MOMENT AT CRITICAL SECTION ALONG WIDTH :
M = Pmax x 0.635 x 0.635 / 2 M= 3.97 T-m Mu = 59.55 KN-m 2 Ast = 567.90 mm ( To be distributed in 1.5 m Length ) 2 Min Req = 420 mm ( Ast = 0.12 x b x D ) Required Spacing of Bar = 12 # @ 195 C/C ALONG WIDTH PROVIDE 12 # @ 150 C/C ALONG WIDTH \ Ast =
753.98
mm2
MOMENT AT CRITICAL SECTION ALONG LENGTH :
M = Pmax x 0.525 x 0.525 / 2 M= 2.71 T-m Mu = 40.71 KN-m 2 Ast = 384.16 mm ( To be distributed in 1.5 m Length ) 2 Min Req = 420 mm ( Ast = 0.12 x b x D )
PROVIDE 12 # @ 265 C/C ALONG LENGTH \ Ast =
426.78
mm2
CHECK FOR ONE WAY SHEAR ALONG LENGTH : Critical Section is at diatance of ' d ' from face of column
0.635 1.50
0.525
0.225
1.50 \ Shear force at critical section = V = \ Actual Shear stress tv =
= = Pt =
\
tc
100 x As b x d
=
0.28 <
=
N / mm2
tv HENCE SAFE
19.69 x 4.43
0.225 T
Vu bxd 1.5 x 1000 x 0.222 100 x 1000 x
4.43 300
x 10000
N / mm2 426.78 300
=
0.14
Pt 0.15 0.2
tc 0.28 0.33
CHECK FOR ONE WAY SHEAR ALONG WIDTH : Critical Section is at diatance of ' d ' from face of column
0.635 1.50
0.525
0.335 1.50 \ Shear force at critical section = V = \ Actual Shear stress tv = = = Pt = \
tc
100 x As b x d
=
0.36 <
= N / mm2
tv HENCE SAFE
19.69 x 6.60
0.335 T
Vu bxd 1.5 x 1000 x 0.330 100 x 1000 x
6.60 300
x 10000
N / mm2 753.98 300
=
0.25
CHECK FOR TWO WAY SHEAR : Critical Section is at distance of 'd/2' from face of column 1.50
0.75 1.50
0.53
d/2 d/2
\ Shear force at Critical Section = = = Critical Perimeter = =
2 x
19.69 x
Area of Shadeded Portion
19.69 x
1.8525
36.48 T 0.75
+
2 x
2.56 m
\ Actual Shear stress tv =
Vu bxd
=
1.5 x 36.48 2560.00 x 300
=
0.712
( CLAUSE 31.3.3 IS 456 : 2000 )
where, ks = ( 0.5+b ) Short Side of Column = 0.23 Long Side of Column = 0.45
Thank you for interesting in our services. We are a non-profit group that run this website to share documents. We need your help to maintenance this website.