Integrasi RBS 6000
Short Description
Cara Mudah Integrasi RBS 6000 Series...
Description
Ericsson Internal 1 (47) Disiapkan (juga bertanggung jawab subjek jika lainnya) No EID / OR / Saifullah RR & Andika EID Mulyawan-10: 005062 Uen Disetujui Diperiksa Referensi Tanggal Rev EID / OR / [Yohanes Prasetyo] R 2010/06/04 C Metode dan Prosedur Commissioning RBS Integrasi 6000 Ericsson Internal 2 (47) Disiapkan (juga bertanggung jawab subjek jika lainnya) No EID / OR / Saifullah RR & Andika EID Mulyawan-10: 005062 Uen Disetujui Diperiksa Referensi Tanggal Rev EID / OR / [Yohanes Prasetyo] R 2010/06/04 C Isi 1 Abstrak ................................................ ................................................ 3 2 Prasyarat ................................................ ........................................ 3 2.1 Peralatan ................................................ ........................................ 3 2.2 Konfigurasi Data ............................................... .................... 3 2.3 Persiapan ................................................ ............................... 4 3 Commissioning RBS 6000 .............................................. ..................... 4 3.1 Menghubungkan ke RBS 6000 ............................................. .................. 4 3.2 Beban O & M Access script Konfigurasi .................................... 6 3.3 Peralatan Konfigurasi Load Situs ........................................ 17 3.4 Load IUB Script .............................................. ........................ 25 3.5 Periksa Sidik Jari ............................................... .................... 28 4 Test Call ............................................... ............................................... 37 5 Penutup Rutinitas ............................................... .......................... 37 6 Tambahan Informasi ............................................... ........................ 38 6.1 Interface Cable ............................................... ........................ 38 6.2 Contoh Script ............................................... ........................ 39 7 Referensi: ............................................... ........................................... 46 Ericsson Internal 3 (47) Disiapkan (juga bertanggung jawab subjek jika lainnya) No EID / OR / Saifullah RR & Andika EID Mulyawan-10: 005062 Uen Disetujui Diperiksa Referensi Tanggal Rev EID / OR / [Yohanes Prasetyo] R 2010/06/04 C 1 Abstrak Dokumen ini menjelaskan bagaimana komisioning dan mengintegrasikan RBS 6000. untuk Instalasi RBS 6000 akan menjelaskan dalam dokumen terpisah. Dalam semua kasus proses Ericsson dan prosedur yang harus diikuti tanpa jika ditetapkan dalam dokumen ini. Kegiatan yang diuraikan dalam dokumen ini tidak
semua inklusif untuk memberikan layanan tersebut. Dokumen ini adalah untuk Insinyur yang bekerja dengan Ericsson (EID / ARP) atau ASP yang sudah memiliki dasar dalam RBS 3000 uji keluarga dan commissioning. 2 Prasyarat Sebelum integrasi memulai hal-hal berikut harus diselesaikan dan dipahami. 2.1 Peralatan Tipis klien atau laptop dengan: Windows (2000, XP atau Vista) termasuk Hyper Terminal atau Putty Perangkat Lunak (mirip• fungsi) Elemen Manager (EMAS) Perangkat Lunak• Java Plug In 1.5 JRE• Kabel LAN (Ethernet Kabel dengan koneksi lurus) dan RJ45 untuk Kabel DB9• ALEX• Moshell (opsional)• 2.2 Konfigurasi Data IP dan konfigurasi router Desain mempersiapkan dokumen oleh tim desain Ericsson Internal 4 (47) Disiapkan (juga bertanggung jawab subjek jika lainnya) No EID / OR / Saifullah RR & Andika EID Mulyawan-10: 005062 Uen Disetujui Diperiksa Referensi Tanggal Rev EID / OR / [Yohanes Prasetyo] R 2010/06/04 C ATND SLJJ RJK_KPPTI2 PA5.xls (8 ... 2.3 Persiapan 1. Membaca dan memahami dokumen instalasi RBS 6000 2. Membaca dan memahami Persyaratan Umum Memasuki Pelanggan Lives Situs 3. Menginformasikan dan mendapatkan persetujuan dari PIC EID, jika akan melakukan sesuatu yang tidak menjelaskan secara contoh dokumen Format HD RBS dll 3 Commissioning RBS 6000 Lakukan langkah-langkah berikut untuk commissioning dan integrasi RBS 6000. Catatan: untuk contoh script akan menempel pada acuan dalam dokumen ini 3.1 Menghubungkan ke RBS 6000 1. Switch Pada Daya RBS 6000 dan harap menunggu hingga RBS bekerja normal. 2. Hubungkan kabel RJ45 untuk DUW port LMT-B dan Laptop di pelabuhan LAN Ericsson Internal 5 (47) Disiapkan (juga bertanggung jawab subjek jika lainnya) No EID / OR / Saifullah RR & Andika EID Mulyawan-10: 005062 Uen
Disetujui Diperiksa Referensi Tanggal Rev EID / OR / [Yohanes Prasetyo] R 2010/06/04 C 3. mengatur klien IP menjadi 169.254.1.2 Subnetmask 255.255.0.0 dan default gateway 169.254.1.1 4. terhubung ke perangkat lunak RBS gunakan Manajer Elemen
5. Isi alamat IP RBS (169.254.1.1) pada kotak Alamat dan klik Connect 6. manajer elemen akan menampilkan
7. membuat RBS memastikan berjalan dengan CV awal
3.2 Beban O & M Access script Konfigurasi Bagian ini akan menjelaskan script OAM beban ke RBS 6000 1. connect to RBS with EMAS software 2. in Element Manager go to Tools O&M Access Configuration
3. windows akses O & M konfigurasi akan ditampilkan dan klik next 4. centang pada file menggunakan konfigurasi jika akan menggunakan scrip OAM atau bisa klik next jika akan mengkonfigurasi secara manual. Juga pilih wizard untuk membuat konfigurasi memastikan semua sudah diperbaiki.
5. klik browse jika skrip menggunakan OAM. Dan menemukan direktori OAM script
6. klik next setelah menemukan script OAM
7. jika sukses OAM script upload ke RBS akan menampilkan gambar berikut dan dari klik next
8. jendela ini menampilkan IP Ethernet RBS, ip ini akan menggunakan jika terhubung langsung ke
penukaran RBS dan transportasi pilih opsi IPv4 atau ATM (silakan lihat desain dokumen). Pilih IPv4 akan menggunakan konfigurasi asli IP dan ATM jika menggunakan Dual stack atau ATM (PDH) konfigurasi. Than klik next
9. this windows showing is Ip address of RBS if will access by remote and Ip address of Ip interface. Don’t forget to select on Gigabitethernetport, select TNA if we use electrical cable connect to transport and select TNB if use optical cable and than click next
10. IP akses ET, antarmuka IP untuk lalu lintas dan ipsynref dari RBS akan menunjukkan kemudian klik next
11. ini adalah rute metrik RBS lalu klik berikutnya
12. server konfigurasi lalu klik berikutnya
13. jendela ini menampilkan dari server NTP untuk RBS, IP ini tergantung dari operator. Dan dari klik next
14. Jaringan ini Sinkronisasi dan kemudian klik next
15. ini adalah ringkasan dari naskah OAM, lalu klik berikutnya
16. RBS akan memuat semua data script
17. koneksi ke RBS kerugian akan, dan dibandingkan akan otomatis terhubung ke RBS
18. OAM konfigurasi berhasil dimuat lalu klik OK
19. koneksi ke RBS akan rugi dan silahkan terhubung ke RBS dengan default IP 169.254.1.1
20. membuat versi konfigurasi (CV) setelah script beban OAM
3.3 Peralatan Konfigurasi Load Situs 1. ◊pada Manajer Elemen pergi ke Tools Konfigurasi Situs Peralatan 2. SE
2. windows konfigurasi SE akan ditampilkan dan klik next
3. centang pada file menggunakan konfigurasi jika akan menggunakan scrip SE atau bisa klik next jika akan mengkonfigurasi secara manual. Juga pilih wizard untuk membuat konfigurasi
memastikan semua sudah dikoreksi
4. klik browse menggunakan jika skrip SE. Dan menemukan SE direktori script lalu klik selanjutnya
5. jika skrip SE akan meng-upload ke RBS akan menampilkan gambar berikut ini dan dari klik next
6. this windows is showing site name and site ID and than click next
7. jendela ini untuk mengkonfigurasi SAU, power supply dan cadangan baterai dan dari klik next
8. this is sector data configuration and than click next
9. ini RBS konfigurasi lokal dan dari klik next
10. ini adalah konfigurasi antena lalu klik berikutnya
11. ini adalah antena cabang konfigurasi lalu klik berikutnya
12. ini adalah konfigurasi antena pengumpan kabel lalu klik berikutnya
13. ini HSDPA dan Eul konfigurasi dan dari klik next
14. jendela ini menunjukkan ringkasan dari situs script peralatan dan dari klik selanjutnya
15. RBS will running SE script
16. click OK after SE script successful and complete loaded
17. create Configuration Version (CV) after load SE script. To create CV
Terjemahan Inggris ke Bahasa Indonesia 3.4 Load IUB Script Bagian ini akan menjelaskan script beban SE ke RBS 6000 1. Run Command File◊pada Manajer Elemen pergi ke Tools
2. click browse to find Iub script directory
3. menemukan direktori script IUB dan dari mulai klik
4. setelah menjalankan sukses, jangan lupa untuk membuat versi Konfigurasi (CV). Untuk membuat CV silakan lihat bagian 3.2 langkah 20.
3.5 Periksa Sidik Jari Sidik jari akan digunakan untuk memesan melalui LKF Elis 1. Dalam Elemen Manager windows pergi ke lisensi (drop down
2. di kanan jendela akan muncul sidik jari RBS. Dalam contoh ini adalah 343401_000440
3. menginformasikan kepada tim Integrasi untuk meminta LKF 4. jika LKF sudah tersedia, meminta tim Integrasi untuk menginstal LKF jika RBS
dapat akses oleh terpencil atau dapat menginstal Situs. 5. pastikan semua parameter telah mengaktifkan dan tidak ada alarm muncul. Silakan lihat penangkapan berikut misalnya3GIP_JATIBARU> st plug 100519-19:01:57 10.213.161.14 7.1y RBS_NODE_MODEL_M_1_8 stopfile=/tmp/23479 Proxy Adm State Op. State MO ========================================================= 24 1 (UNLOCKED) 1 (ENABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1 147 1 (UNLOCKED) 1 (ENABLED) Equipment=1,SectorAntenna=3,AuxPlugInUnit=2 152 1 (UNLOCKED) 1 (ENABLED) Equipment=1,SectorAntenna=3,AuxPlugInUnit=1 160 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=PS1,AuxPlugInUnit=3 164 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=PS1,AuxPlugInUnit=2 182 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=RUW1,RbsSlot=3,AuxPlugInUnit=RUW-1 207 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=RUW1,RbsSlot=7,AuxPlugInUnit=RUW-1 237 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=RUW1,RbsSlot=11,AuxPlugInUnit=RUW1 260 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=BF,AuxPlugInUnit=1 275 1 (UNLOCKED) 1 (ENABLED) Equipment=1,AuxPlugInUnit=SAU_1 320 1 (UNLOCKED) 1 (ENABLED) Equipment=1,AuxPlugInUnit=SCU_1 368 1 (UNLOCKED) 1 (ENABLED) Equipment=1,SectorAntenna=1,AuxPlugInUnit=1 374 1 (UNLOCKED) 1 (ENABLED) Equipment=1,SectorAntenna=1,AuxPlugInUnit=2 409 1 (UNLOCKED) 1 (ENABLED) Equipment=1,SectorAntenna=2,AuxPlugInUnit=2 413 1 (UNLOCKED) 1 (ENABLED) Equipment=1,SectorAntenna=2,AuxPlugInUnit=1 ========================================================= Total: 15 MOs 3GIP_JATIBARU> lst host 100519-19:02:06 10.213.161.14 7.1y RBS_NODE_MODEL_M_1_8 stopfile=/tmp/23479 ========================================================= Proxy Adm State Op. State MO ========================================================= 1174 1 (ENABLED) IpOam=1,Ip=1,IpHostLink=1
1178 1 (UNLOCKED) 1 (ENABLED) IpSystem=1,IpAccessHostEt=1 1179 1 (UNLOCKED) 1 (ENABLED) IpSystem=1,IpAccessHostEt=1,IpSyncRef=7 1180 1 (UNLOCKED) 1 (ENABLED) IpSystem=1,IpAccessHostEt=1,IpSyncRef=8 ========================================================= Total: 4 MOs 3GIP_JATIBARU> lst iub 100519-19:02:08 10.213.161.14 7.1y RBS_NODE_MODEL_M_1_8 stopfile=/tmp/23479 ========================================================= Proxy Adm State Op. State MO 1186 1 (ENABLED) NodeBFunction=1,Iub=4133,NbapDedicated=1 1187 1 (ENABLED) NodeBFunction=1,Iub=4133,NbapCommon=1 ========================================================= Total: 2 MOs 3GIP_JATIBARU> lst ipinter 100519-19:02:11 10.213.161.14 7.1y RBS_NODE_MODEL_M_1_8 stopfile=/tmp/23479 ========================================================= Proxy Adm State Op. State MO ========================================================= 35 1 (ENABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,ExchangeTermina lIp=1,GigaBitEthernet=1,IpInterface=1 36 1 (ENABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,ExchangeTermina lIp=1,GigaBitEthernet=1,IpInterface=2 ========================================================= Total: 2 MOs 3GIP_JATIBARU> lst carr 100519-19:00:52 10.213.161.14 7.1y RBS_NODE_MODEL_M_1_8 stopfile=/tmp/23479 ========================================================= Proxy Adm State Op. State MO ========================================================= 1190 1 (ENABLED) NodeBFunction=1,Sector=1,Carrier=1 1192 1 (ENABLED) NodeBFunction=1,Sector=1,Carrier=1,Ssch=1 1193 1 (ENABLED) NodeBFunction=1,Sector=1,Carrier=1,Psch=1 1194 1 (ENABLED) NodeBFunction=1,Sector=1,Carrier=1,Pcpich=1 1195 1 (ENABLED) NodeBFunction=1,Sector=1,Carrier=1,Pccpch=1 1196 1 (ENABLED) NodeBFunction=1,Sector=1,Carrier=1,Pccpch=1,Bch=1
1197 1 (ENABLED) NodeBFunction=1,Sector=1,Carrier=1,Prach=1 1198 1 (ENABLED) NodeBFunction=1,Sector=1,Carrier=1,Prach=1,Rach=1 1199 1 (ENABLED) NodeBFunction=1,Sector=1,Carrier=1,Aich=1 1200 1 (ENABLED) NodeBFunction=1,Sector=1,Carrier=1,Sccpch=16 1201 1 (ENABLED) NodeBFunction=1,Sector=1,Carrier=1,Sccpch=16,Fach=1 1202 1 (ENABLED) NodeBFunction=1,Sector=1,Carrier=1,Sccpch=16,Fach=2 1203 1 (ENABLED) NodeBFunction=1,Sector=1,Carrier=1,HsDschResources=1 1204 1 (ENABLED) NodeBFunction=1,Sector=1,Carrier=1,Sccpch=20 1205 1 (ENABLED) NodeBFunction=1,Sector=1,Carrier=1,Sccpch=20,Pch=1 1206 1 (ENABLED) NodeBFunction=1,Sector=1,Carrier=1,Pich=1 1207 1 (ENABLED) NodeBFunction=1,Sector=1,Carrier=1,EDchResources=1 1212 1 (ENABLED) NodeBFunction=1,Sector=3,Carrier=1 1214 1 (ENABLED) NodeBFunction=1,Sector=3,Carrier=1,Ssch=1 1215 1 (ENABLED) NodeBFunction=1,Sector=3,Carrier=1,Psch=1 1216 1 (ENABLED) NodeBFunction=1,Sector=3,Carrier=1,Pcpich=1 1217 1 (ENABLED) NodeBFunction=1,Sector=3,Carrier=1,Pccpch=1 1218 1 (ENABLED) NodeBFunction=1,Sector=3,Carrier=1,Pccpch=1,Bch=1 1219 1 (ENABLED) NodeBFunction=1,Sector=3,Carrier=1,Prach=1 1220 1 (ENABLED) NodeBFunction=1,Sector=3,Carrier=1,Prach=1,Rach=1 1221 1 (ENABLED) NodeBFunction=1,Sector=3,Carrier=1,Aich=1 1222 1 (ENABLED) NodeBFunction=1,Sector=3,Carrier=1,Sccpch=4016 1223 1 (ENABLED) NodeBFunction=1,Sector=3,Carrier=1,Sccpch=4016,Fach=1 1224 1 (ENABLED) NodeBFunction=1,Sector=3,Carrier=1,Sccpch=4016,Fach=2 1225 1 (ENABLED) NodeBFunction=1,Sector=3,Carrier=1,HsDschResources=1 1226 1 (ENABLED) NodeBFunction=1,Sector=3,Carrier=1,Sccpch=4020 1227 1 (ENABLED)
NodeBFunction=1,Sector=3,Carrier=1,Sccpch=4020,Pch=1 1228 1 (ENABLED) NodeBFunction=1,Sector=3,Carrier=1,Pich=1 1229 1 (ENABLED) NodeBFunction=1,Sector=3,Carrier=1,EDchResources=1 1232 1 (ENABLED) NodeBFunction=1,Sector=2,Carrier=1 1234 1 (ENABLED) NodeBFunction=1,Sector=2,Carrier=1,Ssch=1 1235 1 (ENABLED) NodeBFunction=1,Sector=2,Carrier=1,Psch=1 1236 1 (ENABLED) NodeBFunction=1,Sector=2,Carrier=1,Pcpich=1 1237 1 (ENABLED) NodeBFunction=1,Sector=2,Carrier=1,Pccpch=1 1238 1 (ENABLED) NodeBFunction=1,Sector=2,Carrier=1,Pccpch=1,Bch=1 1239 1 (ENABLED) NodeBFunction=1,Sector=2,Carrier=1,Prach=1 1240 1 (ENABLED) NodeBFunction=1,Sector=2,Carrier=1,Prach=1,Rach=1 1241 1 (ENABLED) NodeBFunction=1,Sector=2,Carrier=1,Aich=1 1242 1 (ENABLED) NodeBFunction=1,Sector=2,Carrier=1,Sccpch=2016 1243 1 (ENABLED) NodeBFunction=1,Sector=2,Carrier=1,Sccpch=2016,Fach=1 1244 1 (ENABLED) NodeBFunction=1,Sector=2,Carrier=1,Sccpch=2016,Fach=2 1245 1 (ENABLED) NodeBFunction=1,Sector=2,Carrier=1,Sccpch=2020 1246 1 (ENABLED) NodeBFunction=1,Sector=2,Carrier=1,Sccpch=2020,Pch=1 1247 1 (ENABLED) NodeBFunction=1,Sector=2,Carrier=1,Pich=1 1248 1 (ENABLED) NodeBFunction=1,Sector=2,Carrier=1,HsDschResources=1 1249 1 (ENABLED) NodeBFunction=1,Sector=2,Carrier=1,EDchResources=1 ========================================================= Total: 51 MOs 3GIP_JATIBARU> ala 100519-19:00:55 10.213.161.14 7.1y RBS_NODE_MODEL_M_1_8 stopfile=/tmp/23479 Connecting to 10.213.161.14:56834 (CorbaSecurity=OFF, corba_class=2, java=1.5.0_16-rev, jacoms=R71T28, jacorb=R71T31, jacsec=R71T24) Trying file=/home/eandmul/moshell_logfiles/logs_moshell/tempfile s/20100519-190040_23449/ior23449
Resolving the alarm service in OMS... Simple Alarm Client initialized... Starting to retrieve active alarms Nr of active alarms are: 2 ========================================================= Sever Specific Problem Cause Mo-Reference ========================================================= Min NodeBFunction_DlHwUsageExceedsDlLicenseLevel configuration_or_customizing_error NodeBFunction=1 Min NodeBFunction_UlHwUsageExceedsUlLicenseLevel configuration_or_customizing_error NodeBFunction=1 Alarm Id : SubNetwork=NRO_RootMo_R,SubNetwork=RJK_KPPTI2,MeContext=3 GIP_JATIBARU_2 Event Time : May 19, 2010 1:18:54 PM Perceived Severity : Minor Managed Object Class : NodeBFunction Managed Object Instance : SubNetwork=NRO_RootMo_R,SubNetwork=RJK_KPPTI2,MeContext=3 GIP_JATIBARU,ManagedElement=1,NodeBFunction=1 Specific Problem : NodeBFunction_DlHwUsageExceedsDlLicenseLevel Probable Cause : configuration_or_customizing_error Additional Text : LicencedCapacity=48CapacityLimitEnforceDate=2010-10-15 Acknowledged by : Acknowledgement Time : 0 Acknowledgement State: 2 System DN : SubNetwork=NRO_RootMo_R,SubNetwork=RJK_KPPTI2,MeContext=3 GIP_JATIBARU Notification Id : 4 Additional Info : Alarm Id : SubNetwork=NRO_RootMo_R,SubNetwork=RJK_KPPTI2,MeContext=3 GIP_JATIBARU_3 Event Time : May 19, 2010 1:18:56 PM Perceived Severity : Minor Managed Object Class : NodeBFunction Managed Object Instance : SubNetwork=NRO_RootMo_R,SubNetwork=RJK_KPPTI2,MeContext=3 GIP_JATIBARU,ManagedElement=1,NodeBFunction=1 Specific Problem : NodeBFunction_UlHwUsageExceedsUlLicenseLevel Probable Cause : configuration_or_customizing_error Additional Text : LicencedCapacity=96CapacityLimitEnforceDate=2010-10-15 Acknowledged by : Acknowledgement Time : 0 Acknowledgement State: 2
System DN : SubNetwork=NRO_RootMo_R,SubNetwork=RJK_KPPTI2,MeContext=3 GIP_JATIBARU Notification Id : 5 Additional Info : >>> Total: 2 Alarms (0 Critical, 0 Major) 3GIP_JATIBARU> get nodebf 100519-19:01:04 10.213.161.14 7.1y RBS_NODE_MODEL_M_1_8 stopfile=/tmp/23479 ========================================================= 1183 NodeBFunction=1 ========================================================= NodeBFunctionId 1 analogUlAlignIsActive 0 availableRbsChannelElementsDownlink 65 availableRbsChannelElementsUplink 384 branchDiffAbsTime i[24] = -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 branchDiffMeasTime i[24] = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 collectTraceStatus 0 (UNDETERMINED) dlGraceTimeLeft 148 dlLicFractBbPool2 0 dlLimitedByLicenseLevel false eul2msFirstSchedStep 160 eulLowRate 32 eulMaxAllowedSchRate 3968 eulMaxShoRate 5760 eulNoReschUsers 5 eulNonServHwRate 160 eulSchedulingWeight i[16] = 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 eulTargetRate 160 featureState16Qam 1 (ACTIVATED) featureState64Qam 0 (DEACTIVATED) featureStateDlPowerControlEul 0 (DEACTIVATED) featureStateDualStackIub 0 (DEACTIVATED) featureStateEul2msTti 0 (DEACTIVATED) featureStateGrake 0 (DEACTIVATED) featureStateHsdpaFlexibleScheduler 1 (ACTIVATED) featureStateHsdpaImprovedLinkAdaptation 0 (DEACTIVATED) featureStateMbmsIubEfficiency 0 (DEACTIVATED) featureStatePerHarqProcessGrant 0 (DEACTIVATED) featureStateRetCascading 0 (DEACTIVATED) featureStateStandardizedRet 0 (DEACTIVATED) featureStateStandardizedTma 0 (DEACTIVATED) gpehOverloadProtEv -1 gpehRlsSupFailSyncEv -1 gpehRlsSupFoundSyncEv -1 gpehRlsSupLostSyncEv -1
gpehRlsSupStartedEv -1 gpehRlsSupSyncEv -1 gpehUlSyncReachedEv -1 licenseCapacityNum40WPowerAmplifiers 3 licenseCapacityNum60WPowerAmplifiers 3 licenseCapacityNumCarriers 3 licenseCapacityNumEulUsers 32 licenseCapacityNumHsPdschCodes 15 licenseCapacityNumHsdpaUsers 32 licenseCapacityRbsChannelElementsDownlink 48 licenseCapacityRbsChannelElementsUplink 96 licenseState16Qam 1 (ENABLED) licenseState4wayRxDiversity 0 (DISABLED) licenseState64Qam 0 (DISABLED) licenseStateDlPowerControlEul 0 (DISABLED) licenseStateDualStackIub 0 (DISABLED) licenseStateEnhancedLayer2 0 (DISABLED) licenseStateEnhancedUplinkIntroduction 1 (ENABLED) licenseStateEul2msTti 0 (DISABLED) licenseStateFDpchSrbOnHsdpa 0 (DISABLED) licenseStateGrake 0 (DISABLED) licenseStateHsdpaDynamicCodeAllocation 1 (ENABLED) licenseStateHsdpaFlexibleScheduler 1 (ENABLED) licenseStateHsdpaImprovedLinkAdaptation 0 (DISABLED) licenseStateHsdpaIncrementalRedundancy 0 (DISABLED) licenseStateHsdpaMc 0 (DISABLED) licenseStateHsdpaMcInactCtrl 0 (DISABLED) licenseStateMbmsIubEfficiency 0 (DISABLED) licenseStateMimo 0 (DISABLED) licenseStateNum40WPowerAmplifiers 1 (ENABLED) licenseStateNum60WPowerAmplifiers 1 (ENABLED) licenseStateNumCarriers 1 (ENABLED) licenseStateNumEulUsers 1 (ENABLED) licenseStateNumHsPdschCodes 1 (ENABLED) licenseStateNumHsdpaUsers 1 (ENABLED) licenseStatePerHarqProcessGrant 0 (DISABLED) licenseStateRbsChannelElementsDownlink 1 (ENABLED) licenseStateRbsChannelElementsUplink 1 (ENABLED) licenseStateRetCascading 0 (DISABLED) licenseStateRttPositioning 0 (DISABLED) licenseStateStandardizedRet 0 (DISABLED) licenseStateStandardizedTma 0 (DISABLED) nbapDscp 30 sharedEquipmentController steeredHsAllocation false toaeCch 195 toaeDch 170 ulGraceTimeLeft 148 ulLicFractBbPool2 0 ulLimitedByLicenseLevel false userLabel
========================================================= Total: 1 MOs 4 Test Call Lakukan tes panggilan untuk memverifikasi uji fungsi panggilan (suara baru RBS, Video & HSPA serah terima panggilan tes per sektor dan lebih lembut) Menginformasikan hasil tes panggilan ke personil Integrator. Jika hasilnya OK, lanjutkan ke langkah berikutnya. Jika hasilnya TIDAK OK, segera melakukan pemecahan masalah 5 Penutup Rutinitas Sebelum meninggalkan lokasi, memastikan bahwa tindakan berikut telah melakukan 1. Pastikan tidak ada alarm muncul di RBS. 2. Simpan Log (K-get) 3. Rapi situs dan tinggalkan dalam kondisi yang sama seperti yang Anda menemukannya 4. Kunci semua pintu ke situs. 5. Laporan / menghubungi Ericsson supervisor. 6. Laporan / menghubungi Customer PIC. 6 Tambahan Informasi 6.1 Interface Cable Kabel Ethernet• Kabel antarmuka ini digunakan untuk Operasi dan Pemeliharaan tujuan. Ini dihubungkan antara port LMT-B di DUW dan port LAN di Thin Client (Laptop). Silakan lihat di bawah gambar konfigurasi pin sebagai referensi.
Serial Cable Kabel antarmuka ini digunakan untuk memformat flashcard s Node B '. Ini dihubungkan antara LMT pelabuhan-A pada DUW dan port serial di Thin Client (Laptop). Silakan lihat di bawah gambar konfigurasi pin sebagai referensi.
6.2 Contoh Script O• & M Access script Konfigurasi Site Equipment Configuration
IUB Script CREATE ( parent "ManagedElement=1,IpSystem=1" identity 1 moType IpAccessSctp exception none nrOfAttributes 1 ipAccessHostEtRef1 Ref "ManagedElement=1,IpSystem=1,IpAccessHostEt=1" ) CREATE ( parent "ManagedElement=1,TransportNetwork=1" identity 1 moType Sctp exception none nrOfAttributes 3 numberOfAssociations Integer 512 rpuId Ref "ManagedElement=1,SwManagement=1,ReliableProgramUniter=sctp_ host" ipAccessSctpRef Ref "ManagedElement=1,IpSystem=1,IpAccessSctp=1" ) CREATE ( parent "ManagedElement=1,NodeBFunction=1" identity "4133" // change RBS IUB moType Iub exception none nrOfAttributes 4 rbsId Integer 4133 userPlaneTransportOption Struct nrOfElements 2 atm Boolean false ipV4 Boolean true controlPlaneTransportOption Struct nrOfElements 2 atm Boolean false ipV4 Boolean true userPlaneIpResourceRef Ref "ManagedElement=1,IpSystem=1,IpAccessHostEt=1" ) CREATE ( parent "ManagedElement=1,NodeBFunction=1,Iub=4133"
identity "1" moType NbapCommon exception none nrOfAttributes 0 ) CREATE ( parent "ManagedElement=1,NodeBFunction=1,Iub=4133" identity "1" moType NbapDedicated exception none nrOfAttributes 0 ) SET ( mo "ManagedElement=1,NodeBFunction=1" exception none nbapDscp Integer 30 ) SET ( mo "ManagedElement=1,IpOam=1,Ip=1" exception none dscp Integer 8 //CSR1300886 "32" ) SET ( mo "ManagedElement=1,IpSystem=1,IpAccessHostEt=1" exception none ntpDscp Integer 46 ) SET ( mo "ManagedElement=1,Equipment=1,Subrack=1,Slot=1,PlugInUnit=1, ExchangeTerminalIp=1,GigaBitEthernet=1,IpInterface=1" exception none mtu Integer 1444 ) SET ( mo "ManagedElement=1,Equipment=1,Subrack=1,Slot=1,PlugInUnit=1, ExchangeTerminalIp=1,GigaBitEthernet=1,IpInterface=2" exception none mtu Integer 1444 )
7 Reference: 1. File Descriptions for Site Configuration RBS 6201 V2 P7.1.6 --- 13/1551LZA 701 6003 Uen S 2. General Requirement Live Site Network EID-08:007545 Uen