Inband EMS Guidelines for iPASOLINK RTSO/MTS (http://10.7.44.64/)
Step-1( Check Plan)
For Rest of the NE, Root NE IP as GW
For Root NE, Switch/Router IP as GW
Step-2(Check backhaul configuration part from office) START>RUN>cmd Ping GW IP(Router/Switch) -t If successful, go to next step. If not, confirm configuration part from OTS in case of IPBH nodes and from SCL/F&H in case of NTTN cisco/juniper nodes.
Step-3(Adding access for SNMP service) •
User Account/Security Setting>Security Management>Service Status Setting
Step-4(Add VLAN) VLAN service creation:
•
Provisioning>Eth Function Setting>VLAN Setting>VLAN List>Add VLAN ID
Add VLAN @ Eth port:
•
Provisioning>Eth Function Setting>VLAN Setting>MC-A4(Main Board) >Port0X
Step-5 (Add VLAN..contd) •
Assign VLAN by checking ENABLE
Add VLAN @ Modem port:
•
•
Provisioning>Eth Function Setting>VLAN Setting>MODEM> Port0Y Assign VLAN by checking ENABLE(as previous)
N.B. Add VLAN @ all possible Eth and IF ports for both HW and NEC as per planned NE diagram.
Step-6( Network Management Configuration) •
•
Equipment Setup>Network Management Configuration>General Setting>Set up
Enter(As per NE diagram)
• • • •
IPAddress Subnet Mask Default GW Set “No” for Connect NMS Port to NMS
Step-7(Inband Management) •
Equipment Setup>Network Management Configuration>General Setting(Details)>Setup
Step-8(Auto Discovery Usage)
Check Used at all possible Eth ports as per NE diagram to connect following NE
Step-9 ( Modem port naming) • •
Provisioning>Modem Function Setting>Modem port Setting> Select MODEM Type Modem Name
Step-10( Check connectivity with Server) •
Complete successful ping test to ensure reachability from each NE to server Server-1: 172.27.13.41 (Dhaka, Mymensingh) Server-2: 10.183.102.11 (Sylhet, Khulna, Barisal) Server-3: 10.183.31.50 (Bogra, Chittagong, Comilla)
Notes • Better to start from remote end. • For any cluster, GW of root NE is router IP and GW for other NE of same cluster is root NE IP. • Recommended F/W version is 3.XX.XX. • For iPASO400, NE1 port mode should be user instead of management. Equipment setup>Network management configuration>General setting (Details)>setup
• Must Remove all old EMS cables from NMS and NE1 ports. • Ensure each Modem port naming and each used Ethernet port naming during working with each NE. • For any query or observation, send e-mail to
[email protected]