In-band EMS Guidelines for IPASOLINK

April 21, 2017 | Author: Mahbub Uzzaman | Category: N/A
Share Embed Donate


Short Description

hgfhgfhfkkj jgh jhg hjgjhg j gjg jhghgg jk ghg j hgjh g jk jhgjhgj g...

Description

Inband EMS Guidelines for iPASOLINK RTSO/MTS (http://10.7.44.64/)

Step-1( Check Plan)

For Rest of the NE, Root NE IP as GW

For Root NE, Switch/Router IP as GW

Step-2(Check backhaul configuration part from office) START>RUN>cmd Ping GW IP(Router/Switch) -t If successful, go to next step. If not, confirm configuration part from OTS in case of IPBH nodes and from SCL/F&H in case of NTTN cisco/juniper nodes.

Step-3(Adding access for SNMP service) •

User Account/Security Setting>Security Management>Service Status Setting

Step-4(Add VLAN) VLAN service creation:



Provisioning>Eth Function Setting>VLAN Setting>VLAN List>Add VLAN ID

Add VLAN @ Eth port:



Provisioning>Eth Function Setting>VLAN Setting>MC-A4(Main Board) >Port0X

Step-5 (Add VLAN..contd) •

Assign VLAN by checking ENABLE

Add VLAN @ Modem port:





Provisioning>Eth Function Setting>VLAN Setting>MODEM> Port0Y Assign VLAN by checking ENABLE(as previous)

N.B. Add VLAN @ all possible Eth and IF ports for both HW and NEC as per planned NE diagram.

Step-6( Network Management Configuration) •



Equipment Setup>Network Management Configuration>General Setting>Set up

Enter(As per NE diagram)

• • • •

IPAddress Subnet Mask Default GW Set “No” for Connect NMS Port to NMS

Step-7(Inband Management) •

Equipment Setup>Network Management Configuration>General Setting(Details)>Setup

Step-8(Auto Discovery Usage)

Check Used at all possible Eth ports as per NE diagram to connect following NE

Step-9 ( Modem port naming) • •

Provisioning>Modem Function Setting>Modem port Setting> Select MODEM Type Modem Name

Step-10( Check connectivity with Server) •

Complete successful ping test to ensure reachability from each NE to server Server-1: 172.27.13.41 (Dhaka, Mymensingh) Server-2: 10.183.102.11 (Sylhet, Khulna, Barisal) Server-3: 10.183.31.50 (Bogra, Chittagong, Comilla)

Notes • Better to start from remote end. • For any cluster, GW of root NE is router IP and GW for other NE of same cluster is root NE IP. • Recommended F/W version is 3.XX.XX. • For iPASO400, NE1 port mode should be user instead of management. Equipment setup>Network management configuration>General setting (Details)>setup

• Must Remove all old EMS cables from NMS and NE1 ports. • Ensure each Modem port naming and each used Ethernet port naming during working with each NE. • For any query or observation, send e-mail to [email protected]

Thank you