CONTENTS No. 1. 2. 3. 4. 5. 6. 7. 8. 9.

Category LED Solution New & Renewable Energy Intelligent Robot Automation System Pneumatic & Hydraulics Ubiquitous System Electrical & Electronics NI Application & PC Based Control Microprocessor

Pages 2-13 14-41 42-51 52-120 121-153 154-175 176-235 236-278 279-297 www.ptakasa.com

2

LED Solution No. Name of Equipment 1. LED Trainer (Portable Type) Features:           

Type IEG 6615

Quantity 1 Set

Please Contact

Price Picture

Available to understand the configuration of LED modules, the difference between parts, and the operation circuit Operated with program. Offers LED control device processor Supports series •parallel circuit type. Configured with the basic setting of buck, boost, power device control and each module dimming control Allows practicing the control of AC LED lamp power and the monitoring of measured values of control signals Control LED module in PC Emotion control algorithm by using sensors. Allows practicing the control with various sensors (music, temperature/humidity sensor, ambient light sensor, etc.) Supports DMX 512 protocol, and controls with the link with an external lighting controller Available to know the optical characteristics of LED Back Light Unit (BLU), and allows practicing how to measure (luminance, chromaticity, consistency, and viewing angle) according to the international standard Allows practicing each LED module operation control Allows practicing LED darkness & brightness control, PWM control, and dynamic control Allows practicing the connection of various modules, and the measurement with oscilloscope through T.P

www.ptakasa.com

3 Specification:  IEG 6615-1 Main Controller

 •RS485/422/MCU/Master/Slave module •MCU : ATmega 128 •Slave : ATtiny 2313 •RS232/485 Port x 1EA •Supporting ISP •Display : FND 4 Digits •PWM Control •RGB Control VR x 3EA

integrated

•Output Control Speed VR x 1EA •MIC Input Connector 1 x 1EA •Connector Control between modules (26P) 

IEG 6615-3 Bipolar RGB LED Control

IEG 6615-2 AC Dimming •AC Power Control •Power Supply: AC 24V Built-in •Chip LED Dimming x 8EA •Connection Control between modules (26P) •T.P Terminal x 4EA •Injection Case (assembly-type)

•FED Series/Parallel Connection Control •Bipolar, Series/Parallel Connection Control •FED Series Connection Control •Use of TR/MOSFET element •10 bit PWM Control • Injection Case (assembly-type) 

IEG 6615-4 Boost & Buck Control •Positive-electricity Control •Boost and Buck LED Control •Use of MOS FET Element , DC 5V •LED Series Connection Control

•Output Voltage & Current monitoring •10bit PWM, TP Control •Connection Control between Modules (26P) •Injection Case (assembly-type)

www.ptakasa.com

4 

IEG 6615-5 Buck Boost & CUK LED Control



IEG 6615-7 Sensor •Color Sensor •Illumination sensor •Temperature Sensor (Analogue) •Infrared Ray Sensor (Radiometry system) •Sound MIC •FED Serial LED Control •Connection Control between Modules (26P)

•Negative Current Control •Buck Boost and CUK LED Control •Use of MOS FET Element, DC 5V •LED Series Connection Control •10bit PWM, TP Control •Connection Control between Modules (26P) •Injection Case (assembly-type)



•Injection Case (assembly-type)

IEG 6615-6 LED Adjust •LED Current/Voltage Control •Constant Current Control •Injection Case (assembly-type) •RGB Control by classification (5Ф, 8Ф, Chip LED) •Use of MOS FET element, DC 5V •RGB LED Series Connection Control •Output Voltage and Current Monitoring

•Switch Control •Connection Control between modules (26P)  LED Monitoring Software



IEG 6615-8 Storage Box for Module



IEG 6615-9 LED Bar (R/G/B)

Accessories: •Connection Cable •LED Bar •Power code : 1 Set •Operation S/W •Storage Box for Module •Manual

www.ptakasa.com

5 No. Name of Equipment 2. LED Trainer Features:          

Type IEG 6611

Quantity 1 Set

Mount/Dismounts a module in LED practice equipment base. Support DMX 512 protocol and RS485 communications between main body and module LED practice equipment module is composed of 13 parts. Available to check the LED control principle using test point and module characteristic test Offers breadboard to allow practicing the control of various LEDs such as application cciruit configuration, brightness and color control, and how to turn on a ligthing Controls I-V monitoring with Zigbee, PLC, TCP/IP, and PC LabVIEW S/W while being connected with a PC. Allows practicing the basic operation method (Basic operation, constant voltage drive, constant-current drive, and series/parallel connection). Implements smart lighting in combination of LED lighting control, sensor & LED, and ocmmunications via ATmega 128 CPU, and allows parcticing the RS485 communications between modules. Allows practicing the LED control by using LED patern control and various sensors (CDS, IR sensor, compression sensor, and temperature sensor) according to the program. Monitors the measured values of basic circuit and control operation values PWM & Brightness Control, AC LED adjustment brightness and WebBench Steady/ PMW simulation practice. Zigbee & PLC, RS485 & USB communication support, Embedded (Option)

Please Contact

Price Picture



www.ptakasa.com

6 

IEG 6611-3 Control-2 •Full Color LED x 9EA (5V) •Character LCD 8 x 2 Line •ATmega 128 MCU •RS485 x 1EA •Tack S.W x 5EA •TP Point x 11EA •Power On/Off S.W x 1EA

•Connector (32Pin) x 2EA •12V, 5V Supply •AVR-ISP Port 

IEG 6611-4 Basic Circuit

Specification:  IEG 6611-1 Webbench •White LED x 2EA •Steady TP Point x 7EA •PWM TP Point x 8EA •Power On/Off S.W x 1EA •Connector (32Pin) x 2EA •12V, 5V Supply  IEG 6611-2 Control-1 •Full Color LED x 16EA (5V) •Character LCD 8 x 2 Line •ATmega 128 MCU •Connector (32Pin) x 2EA •RS485 x 1EA •12V, 5V Supply •Tack S.W x 5EA •AVR-ISP Port •TP Point x 18EA •Power On/Off S.W x 1EA

•Dip S.W x 3EA (Parallel,

•Base LED x 4EA(R.G.B.W.) Serial, Current) •Voltage LED x 4EA(R.G.B.W.) •TP Point x 24EA •Current LED x 4EA(R.G.B.W.) •Power On/Off S.W x 1EA •Connector (32Pin) x 2EA •Serial LED x 5EA(Red) •12V, 5V Supply •Parallel LED x 5EA(Red) •Selector S.W x 3EA (Color Selector, Voltage Setting,Current Setting)

www.ptakasa.com

7 

IEG 6611-5 Sensor Module •CDS Sensor : 0 ~ 25,000 Lux, DC5V •Pressure Sensor : Measures contact pressure with FSR, DC5V •IR Sensor : 10 ~ 80cm, DC5V •Thermister Sensor •ATmega 128 MCU •USB B Type x 1EA •Tack S.W x 1EA

•Power On/Off S.W x 1EA •Connector (32Pin) x 2EA •12V, 5V Supply •AVR-ISP Port •RS485 x 1EA  IEG 6611-7 Breadboard •12 Line x 35 Column •Power x 2EA, BUS x 1EA •Power protection circuit is mounted •Connector x 1EA (+12, +5V 20Pin) •GND 20Pin Connector x 1EA •Power On/Off S.W x 1EA •Connector (32Pin) x 2EA  IEG 6611-8 IrDA Communication •Infrared Data Com. IR (transmission & reception x 1 EA) •Tack S.W x 8EA •Power On/Off S.W x 1EA •ATmega 8 CPU x 1EA •Connector (32Pin) x 2EA •AVR-ISP Port

 IEG 6611-6 Monitoring Board •Character LCD 16 x 2 Line •ATmega 128 MCU •USB B Type x 1EA •RS485 x 1EA •Tack S.W x 5EA •Power On/Off S.W x 1EA •Connector(32Pin) x 2EA •12V, 5V Supply •16Channel, 1M IPS, 12bit A/D Converter •USB/RS485 Converter S.W x 1EA  IEG 6611-9 Color Detector •Color Sensor x 1EA •Dip S.W x 1EA (LED ON, RED ON, GREEN ON, BLUE ON) •RS485 x 1EA •Power On/Off S.W x 1EA •AVR-ISP Port •ATmega 8 CPU x 1EA •Connector (32Pin) x 2EA •12V, 5V Supply

www.ptakasa.com

8  IEG 6611-10 LED Driver •ATmega 8 CPU x 1EA •RS485 x 1EA •NCP3065 x 1EA (TP Point x 7EA) •FAN5622 x 1EA (TP Point x 3EA) •MAX1570 x 1EA (TP Point x 3EA) •Power On/Off S.W x 1EA •AVR-ISP Port •Connector (32Pin) x 2EA •12V, 5V Supply

www.ptakasa.com

9 No. Name of Equipment 3. Media Facade Trainer Features:        

Type IEG 6691

Quantity 1 Set

Please Contact

Price Picture

Available to practice for control, production and setting up, and lighting design of Media-Facade Implements full color videos: Max. 16-bit color gradation Adjusts the intervals of modules (pixels) freely, and allows module combination of various shapes and outputs It is possible to control by group and to practice interlock control using standalone type controller. Design for Protection against dust, protection against heat and waterproof of IP64 are applied Video Implementation and installation with many integrated systems Secures wide viewing angle with SMD LED Optical communication module, controller for PC control (Option)

Composition: 

IEG 6691-1 Working Board 

IEG 6691-3 Stand-alone type controller

www.ptakasa.com

10 



IEG 6691-2 Facade Module



IEG 6691-5 Terminal Block



IEG 6691-6 LED Software

IEG 6691-4 SMPS

www.ptakasa.com

11 No. Name of Equipment Type Quantity 4. LED & Dimming Control System IEG 6690 1 Set Features:        

Please Contact

Price Picture

Implement the Power line communication lighting control system integrally with Intelligent lighting equipment education system Install and control all types of the lighting including fluoerscent light and LED, and control On/Off Dimming in each lighting fixture Configures LED light devices through actual wiring, and allows parcticing them (for mounting /dismounting and disassembling/ assembling magnet module type) Available for separate control of 64 or 256 groups (extendable) with one controller. Up to 64 screens can be saved Accesses other networks such as Ethernet, and controls lights and load monitoring via a PC or thorugh the Internet in a ermote area Even though partition is changed, additional construction is not erquired. Only needs to change the adderss table allocated to each block With the interwork with a PC, the light in a cloation and the power in a socket can be turned off automatically when no one is theer In standby power, the power of the corresponding socket is automatically blocked. Easy to interwork with ambient light sensor, motion sensor, and intrusion detection sensor

www.ptakasa.com

12 Specification:  IEG 6690-1 Master Controller (MC-1) •Using the 32bit high performance CPU •Ethernet Interface -> LAN by Remote Control •PLC communications (built-in Phase Coupler) •The power consumption of each load can be scanned in real time •Control the lamps based on signals of aperture time, illumination sensor, human body detection sensor •Detecting standby power and controlling disconnection •Monitor displaying Operation- state •R-phase power : Use as a power for operation of master controller unit •S-phase, T-phase: Use it for controlling coupling and power line communication of closed circuit •Applying 4mm double safety protection terminal and magnetic removable module  IEG 6690-2 Lighting Control (LCU-64) •32Bit RISC CPU built-in to control High speed lamp •Applying 4mm double safety protection terminal and magnetic removable module •Up to 64 addresses can be allocated to each lighting fixture •Up to 20 A lighting fixture can be connected •Each lighting fixture enables 100-stage dimming •The current in a lighting fixture can be measured

 IEG 6690-3 UX-100 (LCD형 Controller) •256 lighting fixtures can be controlled in individual and block unit •Maximum 63 scene data can be saved •Function for setting multiple block (one lamp can be applied to various groups at the same time) •Daylight Saving interlocked with time, digital input, analogue input and security system; •Controlling the lighting scene sequentially with Dynamic scene function; •Function of Mode control due to preset scenario; •Displaying power consumption in LMU(Load Measuring Unit); •90~240V AC input power can be used; •5.5W; •RS-232C, RS-485, LAN, USB(master/slave), PLC •IrDA communication; •Built in 4.3” TFT COLOR LCD with a touch screen; •USB, Ethernet interface terminal •Applying 4mm double safety protection terminal and magnetic removable module 

IEG 6690-4 Node (UP-PWM4 / UP-LED 10W) x 2EA •Controls a lighting fixture without closed circuit power line communications function •UP-PWM4 : 400Hz PWM dimming signal output •UP-LED10W : Relay Control (On/Off Control) •Applying 4mm double safety protection magneticremovable module

terminal

and

www.ptakasa.com

13 

IEG 6690-5 Program Switch  IEG 6690-7 Fluorescent light Node •Built in 10 screen sensor switches •Controlling 5 groups of lamps •Set and change the groups without extra work of wiring  IEG 6690-8 LED Node •Blocks a load caused by a switch if it is used with a power control module •Controlling ON/OFF on all lighting fixtures with one switch •Applying 4mm double safety protection terminal and magneticremovable module  IEG 6690-T Working Board •This board consists of 10mm holes with geometric pattern and is  IEG 6690-6 Node (UP-PWM4 / UP-LED 10W) x 2EA color coated after perforating operation •Built in Closed Loop Power Line Control •All types of modules can be removable using magnetic clapping •Built in Color mixing Control device •Controlling 400MHz PWM dimming •Size : 1,000mm(W) x 1,500mm(H) •Controlling On/Off •4 wheels are attached •Applying 4mm double safety protection terminal and magneticremovable Module

Accessories: • Communication cable : 1Set • Power code : 1Set • Manual : 1EA • Download cable : 1EA

www.ptakasa.com

14

New & Renewable Energy No. Name of Equipment 1. Smart Grid Trainer Features:  

 

Type IEG 1800

Quantity 1 Set

Please Contact

Price Picture

It is possible to conduct experimental practice on the principle and operational control of the smart-grid intelligent power network system applied to industrial sites It is possible to measure and control in real time the power consumption of households, plants, buildings and charging stations by using the power source of local generators in case of the short circuits and overloading of commercial power sources through transmission/transformation controllers It is possible to use the power generated by power plants of sun light, wind and hydrogen fuel cells independently as local power plant porvides inverter, regional battery, rechargeable controller Control the power consumption of household devices with smart grid controllers, and, in case the power source turns of for a certain time, manage the eneti rpower and store the data ofr the main sevrer PC’s by cutting off the standby power and using various interfaces (Zigbee, PLC, TCP/IP, Wireless LAN, RS485 etc.)

www.ptakasa.com

15 Specification (Renewable Energy Part):  IEG 1800-1 Region 1, the solar power plant •PV Module - Voc : 21.5Volt / Isc : 690mA - Vop : 17.5Volt - Iop : 590mA / Pmax : 10Watt or higher •Artificial Lighting - Halogen Lamp 300W × 1EA, Protection Lamp, Angle Control •Light Source - Lamp POWER Switch , Brightness Control •DC Voltage Meter : 1EA, DC Ampere Meter : 1EA •Smart Meter - PXA 270 Embedded System - 4.3" TFT LCD Touch Display - Interface : USB Host/ Client, TCP/IP, RS485, RS232C, Zigbee & PLC  IEG 1800-3 Region 3, the fuel cell plant •STACK - H2/Air PEM Fuel Cell Stack × 10EA - Power : 200mW per cell / Power(10cells) : 2W - Electrode area : 4㎠ per cell - Fuel : H2/Air / Genearted voltage : 0.4~0.96 per cell •H2/Air Electrolyzer - Power : 15W at 4DC / Voltage : 3.0 ∼ 4.0V DC - Current : 0 ∼ 4.0A DC / Electrolyzer area : 16㎠ •DC Voltage Meter : 1 EA, DC Ampere Meter : 1 EA •Smart Meter - PXA 270 Embedded System / 4.3" TFT LCD Touch Display - Interface : USB Host/ Client, TCP/IP, RS485, RS232C, Zigbee & PLC



IEG 1800-2 Region 2, the wind power plant •Wind Power Generator - Maximum Power Consumption : 50W - Structure : It is possible to confirm the structure of motors with an ayclirc transparent cover. •Reducer - Reduction Gear : 4 : 1 (Acetal material /

Coupling Connenction) •DC Motor - Maximum Power Consumption : 30W - Input : DC24V / Motor Dricer : × 1EA - FAN × 1EA, RPM Measurement, Wind Speed Measurement •DC Voltage Meter : 1EA, DC Ampere Meter : 1EA •Smart Meter - PXA 270 Embedded System - 4.3" TFT LCD Touch Display - Interface : USB Host/ Client, TCP/IP, RS485, RS232C, Zigbee & PLC

www.ptakasa.com

16 Specification (Power Transmission and Distribution System):  IEG 1800-4 Smart Transmission / Distribution •Supply power to household devices through connection to the commercial power •Convert to local power plants in case of the short circuit and overload of the power •AC Part : AC Watt Meter x 1EA, Digital Watt Hour Meter x 1EA Input S.W xA 1 E •Renewable Energy AC Part : AC Watt Meter × 1EA, a Dtt igHitoaul rW Meter × 1EA, OWu ×tp u1t SEA., Multi Concent × 1EA •Smart Controller : LCD 20 × 4, 설정 Push S.W × 3EA (Resedt,e M, RoUN/STOP) •Interface : RS485, Pin (32pin × 2EA), 9600bps •Zigbee Module

•Region 2, Substation (Wind oPwer) Inverter - Input Voltage : DC10~15V - Output Voltage : AC 220V 50/60Hz - Rated Power : 600W - Output Pulse : Mdoified Sine Wave - 4Φ Terminal : Input, Output × Each 2AE •Region 3, Substation (Fuel Cell) Inverter - Input Voltage : DC 6V - Output Voltage : AC 220V/60Hz - Rated Power : 150W - Output Pulse : Squaer Wave - 4Φ Terminal : Input, Output × Each 2AE - Interface : RS485, Pin (32pin × 2AE)



IEG 1800-5 Stand Alone Inverter / Charging Controller

•Zigbee Module

•Charging Controller - Transmit the output data to the smatr controller with Zigbae method through etxended communication ports since a charging controller is built in each of solar engery, wind power and fuel cells. - Rated Solar Current : 20A / Rated Load Current : 20A / Voltage : 12V - P.V, Load, Batter 4Φ Terminal : 6EA - LED Display : Power, Charging Display •Region 1, Substation (Solar Photovoltaic) Inverter - Input Voltage : DC10~15V - Output Voltage : AC 220V 50/60Hz - Rated Power : 600W - Output Pulse : Mdoified Sine Wave - 4Φ Terminal : Input, Output × Each 2AE

www.ptakasa.com

17 

•Solar Photovoltaic Battery

Specification (Smart Controller Part)  IEG 1800-7 Smart Controller

- Lead Storage Battery : 1EA

•Smart Web Controller

- Voltage : 12V

- Monitor the wattage, set the wattage of each port, and store the wattage data of

- Current : 20A

each port

- Input Terminal : 4Φ × 2EA

- Monitor in real time the operating conditions of household devices, and control the

•Hydrogen Battery : 1EA

power consumption and standby power

- Voltage : 6V

- Monitor in real time and control the equipment drives

- Current : 4A

- Control the conversion to local power plants in case of the overload of the commercial

- Input Terminal : 4Φ × 2EA

power source of Korea Electric Power Corporation

•Wind Power Battery : 1EA

- Implement remote monitoring and control, establish Web Server, and provide

- Voltage : 12V

various PC interfaces

- Current : 20A

- Provide smart grid operating S/W, PXA 270 Embedded System

- Input Terminal : 4Φ × 2EA

•PXA 270 Embedded System

IEG 1800-6 Smart Charging Station

- 7” TFT LCD Touch Display - USB Host/ Client, TCP/IP



IEG 1800-8 Smart illumination/Fan Controller

•AC Watt Meter x 1EA

•illumination, Fan, Power Consumption, Standby Power Control

•Interface : RS 485, RS232C, Zigbee & PLC (9600bps) Pin (32pin x 2EA)

•Fan Output : 10mW

- Zigbee Module

•MR-16 LED Lamp : 1EA •AC Lamp : 1EA •Digital Load : 1EA (Reset, Start, Up, Down Mode) LCD 16 × 2 Line •AC Watt Meter × 1EA •Smart Controller : LCD 20 × 4 Line -Set S.W(Push) × 3EA (Reset, Mode, RUN/STOP) •Interface : RS485, Pin (32pin × 2EA), 9600bps - Zigbee Module

www.ptakasa.com

18 Specification (Smart Home)  IEG 1800-9/13 Smart Fan/Washing Machine



•FAN

•Real time Power Consumption

- Input Power : 12V, Wings Size : 15Cm

Measurement

- AC Watt Meter × 1EA

•Gas Detector, Gas Drive Part, Gas

•Smart Controller : LCD 20 × 4 Line

Setting Meter

-

Push

S.W

×

3EA

(Reset,

Mode,

IEG 1800-10 Smart Curtain / GAS

•Curtain ON/OFF/ Power Consumption / Standby Power Control

•AC Watt Meter × 1 EA

RUN/STOP)

•Smart Controller : LCD 20 × 4

•Interface : RS485, Pin (32pin × 2 EA),

- Push S.W × 3EA (Reset, Mode,

9600bps

RUN/STOP)

- Zigbee Module

•Interface : RS485, Pin (32pin × 2 EA), 9600bps

- •Washing Machine

- Zigbee Module

- Capaciyt : 2Kg - Size : 565 x 335 x 560mm - Weight : 10kg



IEG 1800-12 Smart Refrigerator

- Power Consumption : Washing(160W), Dehydration(90W) - Fixed Profile (Move Type)

•Refrigerator Temperature/ Power Consumption /



•Standby Power Control

IEG 1800-11 Smart TV

•Antenna Input Port •LCD TV Bright / Volume / Power Consumption / Standby Power Control •Real time Power Consumption Measurement

•Real time Power Consumption Measurement •Refrigerator : Low Noise Refrigerator (4L)

•TV : 10.4" Touch LCD (Emebdded Speaker, TN Panel, Analog TV Reception)

(Cold and warmth : 0~5℃, Heat Insulation

•AC Watt Meter × 1 EA

: 50~55℃, o w Per Consumption:48~52W)

•Smart Controller : LCD 20 × 4 EA - Push S.W × 3EA (Reset, Mode, RUN/STOP) •Interface : RS485, Pin (32pin × 2 EA), 9600bps - Zigbee Module

•AC Watt Meter × 1 EA •Smart Controller : LCD 20 × 4

www.ptakasa.com

19 Smart Grid Operating Software:

- Push S.W × 3 EA (Reset, Mode, RUN/STOP) •Interface : RS485, Zigbee & PLC, Pin (32pin × 2 EA), 9600bps - Zigbee Module

Curriculum: Chapter 1. Smart Grid - Outline of Smart Grid - Smart Grid and IT - Stand-alone type Sun light/ Wind power/ Fuel cell generation system - Smart Grid and New & Renewable Energy Chapter 2. Home device for household - Outline of consumption of electrical power and standby power - Structure rand features of intelligent home device

- Establishing the environment of Ubiquitous using home device Chapter 3. Establishment of Intelligent electrical grid - Structure rand features of RS232C, Zigbee, PLC communication - Establishing the smart grid environment -Power transmission and wiring Practice - Monitoring electrical grid in real time - Establishing Web server using TCP/IP Chapter 4. Application practice

Accessories: •Communication cable : 1Set • Power code : 1Set • Manual : 1EA

- Controlling Standby power and power Consumption of home device

Monitoring and controlling Power consumption of home device using PLC(power line communication), USN (Zigbee) - Automatic Meter Reading (electricity, gas) practice

www.ptakasa.com

20 No. Name of Equipment 2. Smart Grid Trainer

Type IEG 1810

Quantity 1 Set

Please Contact

Price Picture

Features: •It is possible to conduct experimental practice on the principle and operational control of the smart-grid intelligent power network system applied to industrial sites •It is possible to measure and control in real time the power consumption of households, plants, buildings and charging stations by using the power source of local generators in case of the short circuits and overloading of commercial power sources through transmission/transformation controllers •Indicate the current status and flow of power supply on the LED display and reverse the flow of power supply on the LED display in case the power consumption of household lamps is greater than the power production. •Control the power consumption of household devices with smart grid controllers, and, in case the power source turns off for a certain time, manage the entire power and store the data for the main server PC's by cutting off the standby power and using various interfaces (Zigbee, PLC, TCP/IP, Wireless LAN, RS485 etc.). •It is possible to establish the web server through TCP/IP and to monitor in real time through the external environment. •In case of the short circuit at a specific position during power supply, it is possible to trace and check the position. In case of +,- connection error during wiring, inform users of the error through a buzzer. Specification:

www.ptakasa.com

21 Curriculum: •Electric power flow observation of electrical grid in real time (SCADA) •Fault section observation of electrical grid in real time (SCADA) •Electrical grid control in each section to restore the fault section •Service restoration by distributed power •Electronics control due to available capacity of ESS during blackout •Real-time management of power consumption graph •Automatic operation on power plant and distributed power management •Manual operation on power plant and distributed power management •Real-time management of graph indicating power consumption •Distributed power management and automatic operation on power plant •Distributed power management and manual operation on power plant •Urgent demand control during electricity peak •Energy storage using ESS •Power control by Korea electric power due to the amount of solar energy generation in household •Standby power of electric appliances/ monitoring driving power •Electric appliances operation due to real-time payment system

Application Software: Smart Grid Application Software: - Graph indicating generation quantity (Korea electric power, wind power) - Graph indicating consumption (household, factory, building, charging stations ) - Graph indicating reservation rate - Electric power transaction setup (setting the reservation rate and the distribution rate)

•Electric appliances control due to seting of the maximum power consumption

Accessories: •Power Code : 1Set •Manual : 1AE •Communication Cable : 1AE

www.ptakasa.com

22 No. Name of Equipment 3. New & Renewable Energy Trainer

Type IEG 1014

Quantity 1 Set

Please Contact

Price Picture

Features: •Fundamental principle on how light changes into electrical energy and each element in photovoltaic system •Experiment for stand-alone and grid connected sunlight generation, wind power, hydrogen hybrid as well as new renewable energy •Understand the structure, principle and concept of standalone inverter, grid connected inverter •Experiment for sunlight generation and series/parallel connection as providing PV 10W & 0.5W cells •Control the trainer and real-time monitoring through TFT LCD as providing Embedded Monitoring System •Measure the performance of PV and fuel cell, voltage/current/ wattage without extra measuring equipment as providing electronic measuring and electronic load, and measure the data of I-V-P characteristic graph and developing condition through PC, and remote monitoring is performed by Web •Environment construction of ubiquitous and various practices through Zigbee & PLC, RS485 using expanding port

Specification:  IEG 1014-1 Monitoring System •PXA 270 Embedded System - 7" TFT LCD Touch Display - USB Host/ Client, TCP/IP •Interface : RS485 (CH1/CH2), RS232C, Zigbee & PLC (9600bps) P i n (32pin × 4 EA) - Zigbee Module

IEG 1014-2 PV Cell (10W) •PV Module : Production of Electricity •Output : 10W x 1 EA (17V,0.59A) •Auxiliary lighting : 300W, Halogen Lamp, Angle Controller x 1 EA •Output Terminal : 2 EA

www.ptakasa.com

23 

IEG 1014-3 Photovoltaic



IEG 1014-4 Charge Controller

•Series-Parallel Connection of Solar Cell

•Charge Control, Reverse/Excess Current

•Rated Power : 0.5W x 6 EA

Protection

•Rated Voltage : 2V

•Capacity : Dedicated DC 12V / 7Ah

•Rated Current : 250mA

Battery × 1 EA

•Open Voltage : 2.3V

•LED Display : 3 EA (Power, Charge

•Maximum Current : 275mA

Indicator, Battery Output)

•Cell terminal : 12EA, Output terminal: 2EA

•Battery On/Off Select S.W: 1 EA •Remaining Charge Capacity LED Level Bar : 1 EA



IEG 1014-5 Digital Multimeter

•Input Voltage : AC 220V

•DC Voltage Meter : 2 EA •DC Ampere Meter : 2 EA



•AC Voltage Meter : 각 1 EA

•Input/Output Voltage : AC 220V

•AC Ampere Meter : 각 1 EA

•Voltage Measurement : 0~170kV

•RS485, Zigbee Connector : 1 EA

•Current Measurement : 0~20kV

IEG 1014-6 Digital Multi Meter

•Active Power : 2000MW ~ +2000MW



IEG 1014-7 AC Load

•Reactive Power : -2000Mvar ~ +2000Mvar

•Fluorescent Light

•Apparent Power : 0~2000Mvar

- Operating Voltage : AC 220V (7W/65Hz)

•Power Factor : -99.9% ~ +100%

•AC Motor

•Frequency : 45~65Hz

- Operating Voltage : AC 110/220V

•Positive Total : 0.000~999999Mwh

- Power Consumption / Speed : 3.5W / 36rpm

•Absolute Total : 0.000kvarh~999999Mvarh

•220V AC Input Terminal: 4EA

www.ptakasa.com

24 

IEG 1014-8 DC Load



IEG 1014-11 Watthour Meter

•DC LED : 3~12VDC

•Monitoring power consumption

•DC MOTOR

•CW during power consumption, CCW

- Operating Voltage : 12V

during general output transmission

- Consumption of electrical power / speed : 0.63W / 6,100rpm

•Single Phase 2 Wire

•DC 12V Input Terminal : 4EA

•Connection of Wire : Top/Bottom,



Left/Right

IEG 1014-9 DC Electronic Loader

•Auto-Increment LOAD Current •Configurable Delay jTiming (Delay Timing Setting) •Push S.W : 3 EA (Reset, Start, Up, Down Mode) •Display : LCD 16 X 2 Line •Input Load Terminal : 2 EA •Input power : AC220V

•Rating : 220V / 40(10)A 60Hz / degree of precision : 2.0 Class •Input(S) / Output(L) terminal : 2EA in each (4Ф safe terminal)



IEG 1014-12 Light Control

•AC/DC Power equipment •Dimmer, Control : Brightness control of the Light •AC Dimmer Controller : 1EA •DC Dimmer Controller : 1EA



IEG 1014-10 DC-DC Converter

•DC/DC Converter - Input/output Voltage : 10~36V / 12V - Output Current : 1.25A (single) •DC FAN - Operating Voltage / Power Consumption: DC 12V / 0.7W (Ball Bearing) - Variable Resistance: 1KΩ •Input Terminal : 2EA

•AC 220V Input Terminal : 3EA (4Ф safe terminal) •DC Input Terminal : 2EA



IEG 1014-13 Grid-Connected Inverter

•Input Voltage Range : DC 10.8 ~ 30V (250W) •AC Output Power : 225W (Maximum 250W) •AC Output Voltage : 220W / 60Hz •Voltage Meter : 1 EA •Ampere Meter : 1 EA •Zigbee Connector / RS-485 : 1EA in each

www.ptakasa.com

25 

IEG 1014-14 Single Phase Inverter



IEG 1010-5 Illuminometer (1~100,000lux)



IEG 1014-16 Infra Red thermometer (Measurable range : 32°C~300°C)

•Input Voltage : 10~15V •Output Voltage : AC 220V (60Hz) •Rated Power : 300W •Output Pulse : Modified Sine Wave •Input Terminal : 2EA •Output Terminal : 2EA (Double Protection) •Test Point Terminal : 6EA •Frequency VR : 1EA



IEG 1014-15 Power Supply

•DC Voltage : 0-30V •DC Current : 0~3A •Analog Voltage Meter : 1EA •Analog Current Meter : 1EA •Output Terminal : 2 EA •VR : 1 EA •Input Power : AC 220V



IEG 1014-16 Loader (LED/Resistor)

•Load (LED & Resistance Setps 11) •LED Loader x 3 EA •Resistor : 3.4 ~ 300Ω

Accessories: • Connection Cable : 1 Set • Manual : 1A E • Table : 1 EA

•Resistor Input Terminal : 2 EA

www.ptakasa.com

26 No. Name of Equipment 4. Renewable Energy Trainer

Type IEG 6615

Quantity 1 Set

Please Contact

Price Picture

Features: •All the modules at the stages of energy production and processing are integrated and it is possible to measure the energy efficiency during the processes of energy production and conversion. •It is possible to conduct the extended practice of new renewable energy by using the characteristic experiments of solar energy and such additional option modules as wind power and fuel cells. •Since AC/DC voltmeters and ampere meters are available, It is possible to confirm the values during the stage of energy conversion without separate measuring instruments. •It is possible to install driven loads to directly test produced energy. •Fabricate the module type so that the circuit may be wired and composed freely. •Provide a separate output port so that users may connect directly the loads except for basic driving parts. •Provide the function of charging fast the consumed batteries during the practice. (the built-in protection circuit operated in case of battery short circuiting) •It is possible to establish the ubiquitous environment and conduct various application practices by using Zigbee & PLC and RS485 through the extended port. Specification (Main Trainer): •AC LOAD 2 (AC Lamp Module)

•INVERTER MODULE

1) AC Power S.W : 1EA

1) DC INPUT

- Rating : AC 250V / 8A, AC 125V / 15A

- 4Pi Terminal 2EA

2) Fluorescent Light : 1EA

2) INVERTER

- Rating : CA 220V / 60Hz

- Input Voltage : 10~12V

- Power Consumption : 4W

- Output Voltage : AC220V, 60Hz

- Lamp Size : 136(W)X16(Φ)mm

- Maximum Output : 200W

- Double Protection Terminal x 2EA

- Reverse Voltage Protection Diode :

•Variable Resistor Module

1N5404

- 300[Ω], 30[W}

- Double Proction Terminal x 2EA

- DC INPUT : 4Pi Terminal x 2EA

3) Inverter Circuit T.P : 5EA

- LED Lamp : DC 12V

www.ptakasa.com

27 •SOLAR CHARGER MODULE 1) BATTERY CHARGER SMPS - Input Voltage : AC85~264V - Output Voltage : 15~18V (Variation through VR) - Output Current : 1A 2) Charging Controller - Input Voltage : DC 15V~30V - Block Over discharge: 11.1V - Block Overcharge : 13.8V - Variation of over-discharged / Overcharged voltage levels - Charging Circuit T.P : 4Point - Input Terminal : 4PI 2EA

•AC LOAD 1 (AC Motor Module) 1) AC Power S.W : 1EA - Rating : AC 250V/8A, AC 125V/15A 2) AC Synchro Motor : 1EA - Voltage : AC 220V - Frequency : 50/60Hz - Output : 2.5 ~ 3W / Seped : 3RPM - Double Proction Terminal x 2EA

•DC Voltage Meter, DC Ampere Meter - Electric Source Voltage : 100-240VAC 50/60Hz - Power Consumption: 5VA - Maximum Display : -1999 ~ 9999 (4 Digit) - RS-485 : 9600bps

•Monitoring System - Garphic LCD : 128X64 DOT - FB-103 SWITCH X 4EA (Reset Mode, RUN, Stop Buton) - I-V, P-V Cuvre Display

•AC Voltage Meter, AC Ampere Meter

- External communication port

- Electric Source Voltage : 100-240VAC 50/60Hz

Communucation : USB oPrt, ZigBee Communication port Support

- Power Consumption : 5VA

•Module Frame

- RS-485 : 9600bps

1) Size : 400(W) x 150(H)mm

- BATTERY Terminal : 4PI 2EA - LOAD OUTPUT : 4PI 2EA 3) Battery - Battery : DC 12V, 7A

•HALOGEN LAMP 1) Halogen Lamp / Floodlight - Floodlight distance : 35 ~45m - Rating: 200W - Material : AL 2) AC Power Input Terminal

2) Material : AL

•SOLAR CELL MODULE 1) Solar Photovoltaic Module - Max.Power : 5W - Max.Power Voltage : 18.5V - Max.Power Current) : 0.3A - Open Circuit Voltage) : 22.7V - Shotr Circuit Current) : 0.32A - Cell yTpe Crystalline Silicon - Cell Number : 36 Cells - Operating Temp. : -40˚C ~+85˚C 2) Solar Photovoltaic Module Frame

Accessories: •Serial Cable : 1 EA •AC Core : 1 Set •Power Cable : 1 EA

- Material : AL, Plastic - Type : Stand Lock

www.ptakasa.com

28 No. Name of Equipment 4. Stand alone type Solar Photovoltaic Trainer (popular type)

Type IEG 1010

Quantity 1 Set

Please Contact

Price Picture

Features: • Provide modules needed to practice the principle of Stand-alone Solar Energy Generation so system configuration and characteristic principle of PV Cell (1.5W), series/paarllel connection, moving equipments for practice are available. • Practice to configure the Stand-alone system using by-pass diode, load module, digital multi meter, illuminometer, thermometer, chagre controller, inverter, battery, artificial illumination and scale •Possible to use Stand-alone system with PV Cell 50W (Option) applied to industrial field Specification:

www.ptakasa.com

29

www.ptakasa.com

30 No. Name of Equipment 5. Energy Conversion Trainer

Type IEG 1900

Quantity 1 Set

Please Contact

Price Picture

Features: •Practice to configure Stand-alone Photovoltaic system and basic course on electrical energy conversion •Consist of single phase of half-wave rectifier circuit, single phase of bridge rectifier circuit, 3 phase half-wave rectifier circuit and 3 phase of bridge rectifier circuit •Consist of Step-Down Converter, Step-Up Converter that can convert into proper voltage for using electrical appliances by utilizing given direct power •Configure DC-AC single-phase inverter, DC-AC three-phase inverter that make connection using solar cell or battery as a power •Configure energy converting circuit using AC voltage 1Ф 6/9/12/18/24V, 3Ф 6/12/18/24V •Configure Stand- alone Photovoltaic system as Generating data monitoring with Zigbee wireless communications using Embedded System and Remote monitoring using TCP/IP from PC and 2 PV Cells (5W), Halogen lamp(300W), Charger, Digital meter, Battery, Electronic load are built in Specification (Rectifier / Step-Down / Loader):  IEG 1900-1 AC-DC Rectifier (1) •Single-phase half wave & Single -phase bridge rectifier circuit •1Φ half wave rectifier circuit with 2 toggle switches and status monitoring LED •1Φ bridge rectifier circuit with status monitoring LED

www.ptakasa.com

31 

IEG 1900-3 Step-Down Power Circuit

•Power circuit down selector & Variable •0/ 5/ 6/ 8/ 9/ 10/ 12/ 15/ 18V Steps 9 •Variable Voltage Down VR



IEG 1900-5 Loader (LED/Resistor

•Load (LED & Resistance Steps 11) •LED Loader (3 color) •Resistor loader (3.4Ω ~ 300Ω)

Experiments: 1. Measuring brightness of light by various light source conditions 2. Experiments of Solar-Cell/ PV module characteristics 3. Measuring “No-load voltage” and “Short-circuit current” due to brightness of light 4. Measuring Voltage of PV module vs Current characteristics curve due to light

Specification (Rectifier / Converter)  IEG 1900-2 AC-DC Rectifier (2) •3Φ half wave rectifier circuit with 2 toggle switches and status monitoring LED •3Φ bridge rectifier circuit with status monitoring LED



IEG 1900-4 DC-DC/DC-AC Converter

•Step up converter (DC inputrange 4 ~ 40V, 4

intensity 5. Measuring Voltage vs Current characteristics curve due to series/parallel connection of PV module 6. Measuring Voltage vs Current characteristics curve due to surface temperature of PV module 7. Measuring output of Solar Cell/Module in a condition of defect of light exposure 8. Experiment of protecting from light- exposure defect of biped diode

9. Battery charging/discharging second time by Solar Cell/Module 10. AC-AC conversion experiment using Single-phase/Three transformer

test opint, separated on/off switch)

11. Experiment of single-phase half wave rectifier circuit

•Square wave inverter (DC 12V fixed input,

12. Experiment of single-phase bridge rectifier circuit

AC 220V output, output indication lamp, 4 test opint, separated on/off switch)

13. Experiment of three-phase half wave rectifier circuit 14. Experiment of three-phase bridge rectifier circuit 15. Experiment of DC-DC Step-Down Converter circuit 16. Experiment of DC-AC square wave inverter circuit

www.ptakasa.com

32 No. Name of Equipment 6. Stand-alone/ Connection form Photovoltaic System (3KW)

Type IEG 1900

Quantity 1 Set

Please Contact

Price Picture

1) The picture of Stand-alone/ Connection form Photovoltaic System 4) Wind speed, Illumination intensity/ amount of solar radiation/

temperature measurement.

2,3) Control part of Photovoltaic System 5) Side of Photovoltaic System 6) monitoring system

www.ptakasa.com

33 No. Name of Equipment 7. Stand Alone Type & Street Lamp

Type IEG 1025

Quantity 1 Set

Please Contact

Price Picture

Features: •Since it is possible to construct a connected system through frame assembling and PV Cell (180W) installation/ wiring, it is also possible to practice the principle, components and check of such a system as the independent streetlight applied to the industry. •Provide on-site practice conditions by supplying PV Cell (50W), PV Cell (180W), LED lamps, a distribution box, digital meters, a fixed frame, mobile illumination lamps, charged controllers, inverters, a connected inverter (600W), solar wiring, junction connectors, basic tools, a cell storage box for profile transfer, and an assembling drawing. •It is possible to practice the series/parallel connections of sunlight generation by supplying 1.5W Cell. •It is possible to practice the replacement and application of various application modules since they are constructed with the atachable/detachable pr ofile method. Street Lamp Laboratory:

www.ptakasa.com

34 No. Name of Equipment 8. Solar Tracker

Type IEG 1021

Quantity 1 Set

Please Contact

Price Picture

Features: •It is possible to display in real time through the PC monitoring system the PLC-based position tracing and operation conditions of the system for practice of solar generation. •Maintain and control at optimum conditions the azimuth and altitude of solar electronic panels by tracing the position of the sun which constantly changes during each hour and season. •Tracker (2-axis PLC control) can drive independently without an external power source since an automatic charging system and above-600W-class inverters are built in it. •By applying Embedded Monitoring System, it is possible to control and monitor in real time the equipment through 7” Touch TFT LCD and to monitor the voltage, electric current, current generation amount and cumulative generation amount of PC-based solar generation. •It is possible to monitor in real time the performance measurement of PV and sunlight, the measurement of voltage, electric current and wattage, and the data for measurement of I-V-P characteristic curve by supplying electronic instruments and load equipment. •It is possible to confirm in real time the wattage through the digital/analog integrating wattmeter on the equipment panel and to practice the analysis and operational characteristics of the wattage caused by overload of the input power source. •It is possible to conduct the control and data collection (providing PLC option) of communication by using ZigBee and RS485 communication and to remote-monitor the amount of generation by means of Embedded Linux Web Server.

www.ptakasa.com

35 Specification:

www.ptakasa.com

36 No. Name of Equipment 9. Hybrid Inverter Trainer

Type IEG 1104

Quantity 1 Set

Please Contact

Price Picture

Features: •It is possible to monitor Accumulated power amount , Current, Wind power generation voltage using PC and real-time monitoring through 7”Touch TFT LCD as applying Embedded Monitoring System •It is possible to monitor the data of I-V-P characteristic curve measurement, measure Wattage, current, voltage, PV and performance of Sunlight in real-time as providing electronic measurement and loading device •It is possible to check the Wattage in real time with power amount, accumulation amount, digital, analogue integrating wattage indicated on panel •It is possible to practice the principles and conceptual principles of 1.5KW hybrid gridconnected inverter system for the new renewable energies of wind power generation and solar generation •It is possible to practice indoors the use of 400W wind power generator (Option) and solar modules as the output power source of new renewable energy •It is possible to construct circuits by connecting them to the panel with 4Φ cable and operate various loads by using load-exchange fluorescent lamps and motor AC outlets. Specification:

www.ptakasa.com

37 No. Name of Equipment Type 10. Wind Power Generation Trainer IEG 1103 Features:

Quantity 1 Set

Please Contact

Price Picture

•Characteristic experiments on the principle of wind power •Controlling/monitoring of equipment by using RS-485 and Zigbee /PLC Modules •It is possible to practice the control and real-time monitoring of equipmentthrough 4.3”Touch TFT LCD by applying Embedded Monitoring System •In order to understand the drive principle of wind power generators and confirm with naked eyes the process of producing electricity, the inside is afbricated into the open type of DSC03233 by installing a generator, a rotor and a drive motor in a transparent acrylic •An inverter, a charged controller, and batteries are located inside the equipment •Provide various practice solutions ranging from the mechanical structure of a wind power generator to the generation principle by driving the load equipment with the power generated in real time •DC Voltage Meter, DC Ampere Meter, Wind Speed Controller 1EA in each

www.ptakasa.com

38

www.ptakasa.com

39 No. Name of Equipment 11. Hydrogen Fuel Cell Trainer Features:

Type IEG 1600

Quantity 1 Set

Please Contact

Price Picture

•Embedded Monitoring Part •It is possible to monitor Current, Voltage generating hydrogen using PC, and Equipment control and real-time monitoring is available with 7”Touch TFT LCD applied Embedded Monitoring System •PEM Fuel Cell Part - Practice with principle of new and renewable energy converted into electric energy using hydrogen fuel cells - Measure Voltage, Current in each PEM Fuel Cell and practice Power production - Support PEM Fuel cell stack generating total 2W (200mW per Cell, total 10 Cells) - Support Electrolysis type hydrogen/oxygen generating device (15W class) - DC Voltage Meter, DC Ampere Meter 1EA in each - DC Load Part : Built in DC voltmeter/amperemeter, LED lamp, DC Motor, adjustable resistance - Photovoltaic Part - DC Voltage Meter, DC Ampere Meter 1EA in each - PV Cell 10W, Halogen Lamp, Light Controller 1EA in each - Practice Energy generation using sunlight - Communication Part : Zigbee, control and collect Data using RS485 communication (PLC Option provided) Monitoring Software:

www.ptakasa.com

40 Specification:  IEG 1600-03 Embedded Monitoring System



IEG 1600-01 PEM Feul Cell Unit •Solar H2 Air PEM Fuel Cell Stick

•It is possible to monitor in eral time and

- Electricity per battery : 200mW

control the current status of hydrogen power

- Total Electric Power (10 EA) : 2W

generation and solar generation

- Fuel : H2/Air

•It is possible to confirm the graph for I-V-W

•H2, Air electrolyzer

output chaarcteristic curves

- Electric Power : 15W 3) Variable

- V: Persent Measured Voltage

Resistor

- A: Persent Measured Current

- Allowable Voltage : DC 0V~40V

- Voc : No-load Terminal Voltage (maximum

- Allowable Current : 1A~5A

voltage of sunlight module during no-load)

- Isc : Shotr-Circuit Current (maximum voltage of sunlight module during full-load) - Vm : Voltage of Maximum Curernt Point (Pmax) - Im : Cuerrnt of Maximum Curernt Point (Pmax); - FF : Fill aFctor

•PXA 270 Embedded System - 7” TFT LCD Touch Display - USB Host/Client, TCP/IP •Interface : RS485, RS232C, Zigbee & PLC (9600bps) Pin(32pin x 4EA) - Zigbee Module

•Variable Resistance : 3.4 ~ 300Ω •Motor (electricity power : 10mW) •LED Lamp : 2 EA •DC Voltmeter / DC Ammeter - Electric Source Voltage : 100~240VAC 50/60Hz - Power Consumption : 5VA - Maximum Display : -1999~9999(4 line) - Communication Type: ZigBee, RS-485 control

- PLC Module (Option) •Features of Voltage value and Current density on Maximum Current Point

www.ptakasa.com

41 

IEG 1600-02 Photovoltaic Unit

•PV Module - Porduction of electricity by PV Module - Efficient practice by brightness and angle of light - Output 10W x 1 AE (17V, 0.59A) - Output Terminal : 2EA •Halogen Lamp - Power : 220V/300W •Lighting Control - Working Voltage : AC220V - Rated Voltage : 1000KW •DC Voltmeter / DC Amperemeter - Power Supply Voltage : 100!240VAC 50/60Hz - Consumption Curernt : 5VA - Maximum Display Range : -1999~9999 (4 line) •Communication Type: ZigBee, RS-485 control

www.ptakasa.com

42

Intelligent Robot No. Name of Equipment 1. Robotics Trainer

Type IEG 2020

Quantity 1 Set

Please Contact

Price Picture

Features: •The basic practice for HRI (Human Robot Interaction), the technology of Perception → Cognition → Expression, which enables the robot to communicate and cooperate with humans by judging users' intent and conducting appropriate responses and behaviors. •Practice such modules as all sorts of sensors and drive parts applied to various intelligent robot platforms, image processing, and voice recognition and synthesis. •It is possible to practice each practice module without its attachment to the main board. •Embody a intelligent virtual scenario through the linkage and collaboration practices between modules. •The extension of additional modules is feasible since each component module is easily detachable/attachable. •It is possible to practice the RFID gang control, the PC gang control, and the gang control through communication from USB to RS232. •Control practice modules with smart phones by fabricating directly Android App. •It is possible to practice various high-performance CPU's by using ATmega128 and Cortex M3. MCU modules are attachable /detachable and other MCU's are convenient to apply. Specification:  IEG 2020-1 Main Controller •Main Controller - MCU : (Basic)ATmega 128 / (Option)Cortex M3, Etc - RS485 Communication, USB to Serial I/F - Display : Text LCD, LED Display X 2EA - CPU Download : ISP - Power : 12V - RFID : 13.56Mhz, ISO/1EC 1443 A/B Standadr - Confirm and control the conditions for the control board of each module.

www.ptakasa.com

43 

IEG 2020-3 Stepping Motor



IEG 2020-5Gripper & Pressure Sensor

•Stepping Motor

•Griper Module

- Power : 12V, 5V

- Power : 12V to 5V

- Phase Current : 1,2A

- Metal Frame

- Rated Torque : 2.06 ㎏/㎝

- RC Motor : 180˚ Rotate, 5V

- Step Angle : 1.8/0.9

- Speed : 0.2sec/60˚ , Torque : 3.2㎏/㎝

- Rotor Inertia Moment : 33g/㎠

•Press Sensor

- Step angle Checking Panel

- Power : 12v to 5V



- Active Area : 5Ø

IEG 2020-4 DC Motor

•DC Motor

- Force Sensitivity : 100g~10Kg

- Power : 12V, 5V

- Pressure Sensitivity : 0.1㎏/㎠ ~ 10㎏/㎠

- Rated Torque : 2.0 ㎏/㎝ - Rpm : 102, Reduction Gear Ratio : 1/50



- Geared Motor Encoder : 5V, A,/B Phase Output

•Ultrasonic Sensor

- Built in Photo Interrupter

- Power : 12V to 5V

- DC Motor Driver

- sensitivity : -63dB



- Directivity : 50˚

IEG 2020-2 RC Motor & Gyro Sensor

IEG 2020-6 Ultrasonic & IR Sensor

•Camera Module

- Measurement Distance : 0.2~6M

- Power : 5V

•IR Sensor

- CMOS IMAGE SENSOR

- Power : 12v, 5V

- 300 Megapixel, Static image capture (2560X1920)

- Measurement Distance : 10~80㎝

- Video Capture : 30 frame/sec

- Analog Output

•RC Motor - Power : 12Vto 5V



- Metal Gear

- Power : 2.7V ~ 5.5V

- (Pan) Rated Torque : 3.2 ㎏/㎝ (Speed : 0.1 sec/60°)

- RED, GREEN, BLUE

- (Tilt) Rated Torque : 1.5 ㎏/㎝ (Speed : 0.11sec/60°)

- Identification Type :

•Gyro Sensor

high-intensity LEDtation

IEG 2020-10 Color Sensor

- Power : 5V to 3.3V - 2AXIS; Analog Output : 1x, 4x amplified; - Bulit in Low Pass Filter

www.ptakasa.com

44 

IEG 2020-7 PIR/GAS/Cds Sensor



IEG 2020-9 Display

•PIR (Human Body Detecting) Sensor

- Power : 12v, 5V

- Power : 12V to 5V

- Dot Matrix(8X8) 2EA

- Sensor Window size : 4X3mm

- TEXT Display

- Output : more than 3.5V [Vp-p]

- Robot emotion representation

- Sensitivity : more than 3300V/W - NOISE : less than 70mV [Vp-p] •Gas Sensor - Power : 12V to 5V - heatung Type, Heater Voltage : 5V

WinAVR and MSRDS Programming:

- Sensor Resistance : (Rs: Methane at 1000ppm/air) •Illuminance Sensor - Power : 12V to 5V - Resistance value change due to brightness - Light : 5~10㏀ - Dark : 0.5~10㏁



IEG 2020-8 Touch & Bumper Sensor

•Touch Sensor - Power : 12V to 5V - Electronic Capacity Touch - Support for 3-stage sensitivity setting mode - Open-Drain Output - Power Inside : Reset - Built-in circuit for reduction of video and general noise •Bumper Sensor - Power : 12v to 5V - Open-Collector Output - Embodiment of bumper sensor by using micro-switch (hinge roller lever type)

Accessories: •Communication Cable : 1 SET •Manual : 1 AE •Sotfware CD : 1 EA • Download Cable : 1 EA

Software (PC Control):

www.ptakasa.com

45 Experiments: •DC

•Radiometry System

- Operation principle

- Principle of Sensor

- Understand Driving method and Circuit

- Understand Sensor I/F and Circuit

- Application and principle of Enocder

- Parctice with Micom

- Practice for location and speed control

(sensor sensing temeprature change)

•Stepping

•Intensity of illumination

- Operation principle

- Principle of Sensor

- Driving method and understanding Circuit

- Understand Sensor I/F and Circuit

- Parctice for location and speed control

- Parctice with Micom

•RC Servo

(measuring brightness of light)

- Operation principle

•Touch and bumper

- Driving method and understanding Circuit

- Principle of Sensor

- Parctice for location control

- Understand Sensor I/F and Circuit

- Parctice PAN/ TILT

- Conotrl Contact Sensor with capacitance

•Gas

•Ultrasonic Waves

type

- Principle of Sensor

- Principle of Sensor

- Parctice for Operation by impacts

- Understand Sensor I/F and Circuit

- Understand Sensor I/F and Circuit

•Camera

- Parctice with Micom

- Parctice with Micom

- Understand Image Sensor

(C O2 detected(heat transfer type of gas)

(detecting obstacle and measuring distance)

- Image acquisition and output

•Gripper & Pressure Sensor

•Infrared Light

- Pattern recognition of screen image

- Understand Pressure Sensor

•Production of Android App (Option) - App Porgramming - Robot monitoring using App - Robot control using App

- Principle of Sensor

- Parctice Sensor control

- Understand Sensor I/F and Circuit

- Parctice motor control for gripping

- Parctice with Micom (measuring distance)

•Integration Coupling Project on Practice Module

•Tilt

- Vitrual practice with Robot for guide and PR

- Principle of Sensor

- Vitrual practice with Robot for surveillance

- Understand Sensor I/F and Circuit

- Virtual practice with Robot for medical rehabilitation

- Parctice with Micom

- Virtual practice with Robot for domestic

(measuring tilt of X axis and Y axis)

www.ptakasa.com

46 No. Name of Equipment 2. Manipulator Trainer Features:

Type IEG 2040

Quantity 1 Set

Please Contact

Price Picture

•It is possible to understand the structure and principle of robot manipulators and practice the operation and control technology of industrial manipulators and humanoidtype manipulators. •it is possible to practice professionally the Forward Kinematics and Inverse Kinematics due to adoption of 5-axis multi-joint . •Practice the functions of vertical multi-joint robots including object sensing, phage, classification, and transfer control. •It is possible to practice the arm operation of humanoid robots. •It is possible to practice motion generation by using the 3D motion generation simulator. •It is possible to adjust and control in real time the PID Gain of each joint. •It is possible to practice experiments on various high-performance CPU's by using ATmega128 and Cortex M3. •It is possible to apply various MCU's since they are detachable /attachable. Specification: •Digital Servo Motor A(1EA) - Size : 44.5mm(W) X 24.0mm(D) X 32.0(H) - Weight : 60g - Input Voltage : 7 ~ 12V DC - Stop Torque : [email protected] - Operating Angle : 320˚, continuous Rotation - Feedback : Position, Speed, Temp, Overload, Voltage, etc - Features : PID, Feedforward, Ladder Type Speed Profile, Speed Override, Torque Saturator & Offset, Overload Prevention, Absolute Position Adjustment, Deadband, etc •Digital Servo Motor B(4EA) - Size : 44.5mm(W) X 24.0mm(D) X 32.0(H) - Weight : 45g - Input Voltage : 7.4V DC - Stop Torque : [email protected] - Operating Angle : 320˚, continuous Rotation

www.ptakasa.com

47 - Feedback : Position, Speed, Temp, Overload, Voltage, etc - Features : PID, Feedforward, Ladder Type Speed Profile, Speed Override, Torque Saturator & Offset, Overload Prevention, Absolute Position Adjustment, Deadband, etc •Control Board - MCU : (Basic) ATmega128 / (Option) Cortex-M3, Etc - Download Type : ISP - 5 Dof(1 Gripper) - Color Sensor : Power (2.7V ~ 5.5V) RED, GREENU, EB L Identification type (high-intensity LED) - Press Sensor : Power (12v to 5V) Active Area : 5Ø Force Sensitivity : 100g~10Kg Pressure Sensitivity (0.1㎏/㎠ ~ 10㎏/㎠)

① Spot for object (can be designated by users) ② 5-Axis Multi-joint Robot (gripper is included) ③ 3Supply place of Object (analyzing object detecting colors)

Experiments:

④ Practice Module of Twinaxis Joint Robot

•General information

(Motor setup, direct kinematics/ inverse kinematics practice)

•Types of manipulator

⑤ I/O Port (possible for porting robot control program)

•Experiment of motor characteristic

⑥ Monitoring (monitoring Manipulator condition)

•Practice for designing equipment of twinaxis manipulator

⑦ Control button for Manipulator

•Practice for disassembling / assembling twinaxis manipulator

⑧ Emergency Switch

•Practice control programming of manipulator •Understand Kinematics (direct kinematics/inverse kinematics) of manipulator •Create Manipulator track •Practice End-Effect control •Practice Pick & Place using Five-axis machining •Analyze Object - grip - transfer - load using Five-axis machining •Design and simulate Manipulator using Simulator( twinaxis ~ five-axis)

www.ptakasa.com

48

Accessories: •Communication Cable : 1 Set •Manual : 1 AE •Sotfware CD : 1 EA •Download Cable : 1 EA

www.ptakasa.com

49 No. Name of Equipment 3. Multi Robot Trainer

Type IEG 2010

Quantity 1 Set

Please Contact

Price Picture

Features: •Practice Micom Programming and expect best result from the basic to application courses •Micro Mouse, Line Tracer, RC Soccer Robot are possible with one robot •Support 3 MUs - 8051, AVR, PIC •Downloading ISP (In System Programming) is available •Practice Programming with C-Language •Acquiring technique to control the robot to play Soccer game, obstacle tournament and to drive in the maze using RC controller •Specially designed Robot Base Plate provides safe robot practical practice of Stepping motor control, Infrared ray sensor detection, character LCD display, digital I/O control, buzzer control and RF control on the experimental table •It is ranked No.1 in obstacle avoidance in 2006 Robot Olympia (in Sydney, Australia) 



IEG 2010-1 •8051 (T89C51AC2)

IEG 2010-3

•CPU : T89C51AC2

•PIC (18F452)

•System Clock : 20MHz

•CPU : 18F452

•Flash Memory : 32kbyte

•System Clock : 10MHz

•ISP Port : 3 Pin

•Flash Memory : 32kbyte •ISP Port : 3 Pin



IEG 2010-2

•AVR (ATmega32) •CPU : ATmega32 •System Clock : 16MHz •Flash Memory : 32kbyte •ISP Port : 3 Pin •J-Tag Port : 6 Pin

www.ptakasa.com

50 

IEG 2014 Multi-RC Robot

•High-speed RF Control Method using 3 kinds of MCU (8051, AVR, PIC) •Driving in the maze, playing soccer game, obstacle

tournament are available with using RC controller •Acquiring Control Technique needed to control Robot Combat using RC controller •Providing development library and source •MCU :T89C51AC2/ ATmega32/PIC18F452 •Motor : Stepping Motor x 2EA •RC Body: Aluminum Set

www.ptakasa.com

51 No. Name of Equipment 4. Automation Robot System Features:

Type IEG 2050

Quantity 1 Set

Please Contact

Price Picture

•This is the automated robot fabrication system based on ATmega128 and Cortex M3 MCU used a lot in the industry. It is possible to control PC's and LabVIEW monitoring. •This is the equipment from which it is possible to know various processes to perform tasks related to production, the requisite of process automation, and it is composed of supply equipment, drill processing equipment, belt conveyor transfer equipment, sensor sensing equipment, off-spec extraction equipment, vision system and a good-product loading warehouse. •Since air units, solenoid valves and controlling cylinders are built in the system, if air is supplied, it is operated without separate equipment, and the independent self-operation and interlocked experiments are feasible. •Construct a vision system with the smart cameras driven by processors for the real-time target of machine vision. •It is possible to operate all the processes in real time. Control the precise position of the good-product loading warehouse system by using high-performance DC motors and drives. •It is possible to conduct the real wiring connection and PC control experiments of the automated robot fabrication system by using MCU and PLC.

www.ptakasa.com

52

Automation System No. Name of Equipment 1. SIEMENS PLC System

Type IEG 3210-S

Quantity 1 Set

Please Contact

Price Picture

Features: •SIEMENS STEP 7300 PLC Module loading type •PLC Module replacement type according to various PLC model •Peripheral device is modularized, so appropriate teaching and practice for driving control is available by using DC motor, DC Geared motor and stepping motor •Practice for I/O control and various PLC application control •Input 32 points, Output 32 points, built-in connector •Possible to practice as changing various application module

www.ptakasa.com

53 No. Name of Equipment 2. SIEMENS PLC Trainer (S7-300)

Type IEG 3221S

Quantity 1 Set

3. PLC Trainer (SIEMENS S7200CN)

IEG R3220S7

1 Set

Please Contact

Price Picture

Picture

www.ptakasa.com

54 No. Name of Equipment 4. Control Application Trainer (S7-1200)

Type IEG 3241

Quantity 1 Set

5. PLC Trainer (SIEMEN S7-300 CPU)

IEG 3226S10

1 Set

Please Contact

Price Picture

Picture

www.ptakasa.com

55 No. Name of Equipment 6. PLC Trainer (SIEMENS S7-300)

IEG 3226-17

Type

7. PLC Trainer (SIEMENS SIMATIC S7-300)

IEG 3226S11

Quantity 1 Set

1 Set

Please Contact

Price Picture

Picture

www.ptakasa.com

56 No. Name of Equipment 8. X-Y-Z Gantry Robot Trainer

Type IEG 2600

Quantity 1 Set

9. Inverter Trainer

IEG 3770

1 Set

(SIEMENS S7-30D)

Please Contact

Price Picture

Picture

www.ptakasa.com

57 No. Name of Equipment 10. PLC Trainer (SIEMENS S7-200CN)

Type IEG 3120

11. Mechatronics Trainer (SIEMENS S7-300) IEG 3130

Quantity 1 Set

1 Set

Please Contact

Price Picture

Picture

www.ptakasa.com

58 No. Name of Equipment Type 12. PLC Trainer (SIMENS S7-300 CPU) IEG 3746

13. Control Application Trainer

IEG 3249L

Quantity 1 Set

1 Set

Please Contact

Price Picture

Picture

www.ptakasa.com

59 No. Name of Equipment 14. SMSCP Training equipment (Pallet transfer method

Type IEG 3430

Quantity 1 Set

IEG 3432

1 Set

Please Contact

Price Picture

1) Provide pallet 2) Provide material 3) Provide bearing & test 4) Provide press 5) Provide shaft & test 6) Provide vision & cover & monitoring 7) Robot & assembly (ABB Robot) 8) Storage 9) Lift

15. SMSCP Training equipment (Profibus Remote I/O)

Picture

1) Provide material 2) Inspect material 3) Inspect product 4) sorting/queuing station 5) Robot application assembly (ABB Robot) 6) Bolt fastened method 7) Storage

www.ptakasa.com

60 No. Name of Equipment 16. SMSCP Training equipment (Cell transfer method

Type IEG 3433

Quantity 1 Set

IEG 2212

1 Set

Please Contact

Price Picture

1) Provide material 2) Inspect material 3) Inspect product 4) Queuing station & standby 5) Assembly (PTP Robot) 6) Store product

17. SMSCP Training equipment (Cell transfer method)

Picture

www.ptakasa.com

61 No. Name of Equipment 18. SMSCP Training equipment

Type IEG 3432

Quantity 1 Set

Please Contact

Price Picture

Features: •Device for license acquisition of SMSCP Level 1,2,3 from German SIMENS and possible to acquire electrical/mechanical control skill, analog sensor control skill, pneumatic control skill •One or more than 2 stations are practiced with using 8 devices on stations •Practice for configuring of Profibus PLC Network using DP Port as applying Siemens S7-300 Series 314C-2DP model to each station •Understanding mechanism through disassembly/assembly of hardware by user •Cell transfer method such as conveyor, robot, index table for distribution application of production system. System configuration (H/W):

www.ptakasa.com

62 

IEG 3432-1 Pick and Place Feeding Station (provide material)



IEG 3431-3 Indexing Station (Inspect product)

Main components:

Main components:

•Material supply

•Index table module

•Pneumatic robot

- Motor and all kinds of sensor

transfer system

- Cylinder

•Pneumatic gripper

•Pneumatic gripper

transfer system

transfer device

•Control system (PLC)

•Control system (PLC)

•O/P Panel

•O/P Panel

Content of Practice:

Content of Practice:

•Practice for material transfer process

•Understanding about equipments of material

•Principle and operation training of vacuum generator

supply typed

•Use of pneumatic device such as loadless cylinder

•Application for all kinds of sensing sensor and

•Transfer using vacuum generator and vacuum adsorption

understanding of the features

•Practice for PLC program control and defect tracking

•Operation principle of sensor and practice for operation •Practice for drive control of pneumatic module



IEG 3432-2 Gauging Station (inspect material)

Main components:

•Control index table using stepping motor •Practice for PLC program control and defect tracking

•Material transfer module - Ball Screw - DC Geared MOTOR •Control system (PLC) •O/P Panel Content of Practice: •Material transfer process and practice for pneumatic module drive control •Practice for controlling clockwise/ counterclockwise direction on DC motor and practice for brake control •Ball screw and guide : rotation -> direct motion control •Control the material test with displacement sensor

www.ptakasa.com

63 

IEG 3432-4 Sorting and Queuing Station

Main components

•Bolt fastened module

- Motor, all kinds of sensor

- Motor, all kinds of sensor, cylinder

- Cylinder and etc

•Belt driven type of transfer module for light

•Control system (PLC)

weighted high speed

•O/P Panel

•Control system (PLC)

Content of Practice •Practice for material transfer process •Sorting control using DC motor and conveyor •Sorting process control of material using sensor •Practice drive control of pneumatic module •Practice PLC program control and defect tracking

IEG 3432-5 Servo Robotic Assembly (robot application assembly)

Main components •Provide control valve handle •Provide control valve shaft

•Practice bolt fastened method with DC motor •Practice for bolt fastened process with sensor •Practice drive control of pneumatic module •Practice PLC program control and defect tracking Main components

•Practice temperature assembly of •Practice drive control of pneumatic

•O/P Panel

•Practice for material transfer process



•Double acting cylinder

•Control system (PLC)

Content of Practice:

•Practice material transfer process bolt using DC motor

•Articulated robot (six axis)

•O/P Panel

Content of Practice

•Bolt supply module for material transfer

IEG 3432-6 Torquing Station (bolt fastened method)

Main components:

•Conveyor module





IEG 3432-7 Parts Storage

•Pneumatic robot system •Control system (PLC)

module

•O/P Panel; •Storage Module

•Practice PLC program control and

Content of Practice

defect tracking

•Practice for material transfer process

•Position control with vertical articulated

•Practice pneumatic and position control using

robot

pneumatic cylinder •Practice for bolt fastened process using sensor •Practice drive control of pneumatic module •Practice PLC program control and defect tracking

www.ptakasa.com

64 No. Name of Equipment 19. OMRON PLC System

Type IEG 3230

Quantity 1 Set

Please Contact

Price Picture

www.ptakasa.com

65

www.ptakasa.com

66

www.ptakasa.com

67 No. Name of Equipment 20. AB PLC System

Type IEG 3210-A

Quantity 1 Set

Please Contact

Price Picture

Features: •All kinds of equipments such as PLC, sequence control needed of automatic control skill are provided as a module form to be able to practice for application experiment •Possible to practice for controlling clock wise/counterclockwise direction and rectilineal movement by using DC motor, DC Geard motor, stepping motor •Possible to practice basic I/O control and various PLC applications with using module •Structured to control and operate all kinds of modules such as electropneumatic control, PLC control, sensor control, all kinds of motor controls, handling control, microprocessor control, HMI(MMI) control •Possible to practice various applications as interlocked with all kinds of motor control, sequence control, all kinds of sensors by using AB PLC

www.ptakasa.com

68 IEG 3226-A PLC Trainer (AB Compact Logix L32E CPU) •Logix controller : compact flash memory, embedded communication •Digital Input / Output : input 16 / output 16 •Analog Input / Output : input 4 / output 4 •Power supply : 1EA - Compact 124/240V ac expanded power supply device - Operating voltage range : 85~265V AC, 47-63Hz - Current capacity : 2.0A @5V, 0.8A@24V - 24V DC user’s electricity capacity : 250mA - Instant Compensation for circuit loss: 10ms-10s

www.ptakasa.com

69 No. Name of Equipment 21. MITSUBISHI PLC System

Type IEG 3210-M

Quantity 1 Set

Please Contact

Price Picture

Features: •MITSUBISH Q01/Q02 PLC Module loading type •PLC module replacement type according to various PLC model •Peripheral device is modularized, so appropriate teaching and practice for straight forward control is available by using DC motor, DC Geared motor and stepping motor •Practice for basic I/O control using module and various PLC application test •Input 32 points, Output 32 points •Possible for practice as changing various application modules

www.ptakasa.com

70

www.ptakasa.com

71

www.ptakasa.com

72

www.ptakasa.com

73

www.ptakasa.com

74

www.ptakasa.com

75

www.ptakasa.com

76 No. Name of Equipment 22. Process Control System

Type IEG 3450

Quantity 1 Set

Please Contact

Price Picture

www.ptakasa.com

77

www.ptakasa.com

78 No. Name of Equipment 23. LS Industrial system PLC System

Type IEG 3210-LX

Quantity 1 Set

Please Contact

Price Picture

Features: •LS Industrial Systems XGT CPU mounted type PLC trainer •PLC module replacement type according to various PLC models •Peripheral device is modularized, so appropriate teaching and practicing of driving control is available by using DC motor, DC Geared motor and stepping motor •Basic I/O control with module •Modularization of I/O device needed for PLC input/output programming and practice for various programming of basic and operation process •Possible to practice speed of motor, normal rotation/counterturn, and position control •Possible to practice as replacing various application modules

www.ptakasa.com

79

www.ptakasa.com

80

www.ptakasa.com

81

www.ptakasa.com

82

www.ptakasa.com

83

www.ptakasa.com

84 No. Name of Equipment 24. Mini MPS Trainer

Type IEG 3400

Quantity 1 Set

Please Contact

Price Picture

Features: •Training device for the Korean National Certification Practical Test of Certified Mechatronics Technician or Industrial Technician •Fostering an application technique through multi-organization of various control components •Control components of machine, electricity and electronic are installed •USB interface date communication and control are available •Fostering a control ability of various programs such as PLC and microprocessor •Providing a 3D assembly simulation sotfware through flash and assembly/disassembly drawings to understand the tool design and assembly porcess easily

www.ptakasa.com

85

www.ptakasa.com

86 No. Name of Equipment 25. Automated Manufacturing System

Type IEG 3100

Quantity 1 Set

Please Contact

Price Picture

IEG 3100 Automated Manufacturing System (LS Glofa GM6) •KOREA national certification practical test device for certified production automation technician •Consist of component feeder, drill processing system, belt conveyer transfer equipment, sensor sensing device, extractiondevice for defective product, loading case for imported goods, loading case ofr defective product and etc. •Air unit, solenoid valve and control cylinder are equipped so that it operates without any additional device once air is provided, and possible for self driving and linkage with other equipments •Comprehension and controlling practice on production automation process such as supply, manufacture, sort and storage processing •Practice for basic control of automation system using various kinds of PLC •Interlocking operation with counter/ timer function and motor control

www.ptakasa.com

87 No. Name of Equipment 26. Production automation (Vision System)

Type IEG 3101

Quantity 1 Set

Please Contact

Price Picture

IEG 3101 Production automation (Vision System) •Practice equipment linked to machine vision cameras and production automation •Same structure as the production automation test equipment of licensed technicians and consist of the supply, processing, delivery, transfer, inspection, and purge processes of the product •Possible to practice controlling device with PLC programming and distinguish more than two items through machine vision cameras during inspection process •Understand the basic principle and concept of the vision practice, and practice such application as camera sensing •All the input/output signals are digitally communicated with PC’s through signal transmission cables •Possible to practice the application of RFID experimental equipment in linkage to USN experimental equipment

www.ptakasa.com

88 No. Name of Equipment 27. Mechatronics Project Trainer

Type IEG 3104

Quantity 1 Set

Please Contact

Price Picture

Features: • Training equipment for national technical conference, mechatronics 2,4,6 •Using pneumatic, electron, electricity components applied to industrial field •Fostering application technique as consisting of various control elements •Components are equipped to control the machine, electricity, electron elements •Providing electronic statistical textbook and library for 3D assembly simulation •Providing electronic statistical textbook and library for 3D assembly simulation Product Configuration:

www.ptakasa.com

89

www.ptakasa.com

90

www.ptakasa.com

91

www.ptakasa.com

92

Automation Simulation Software / Manual:

www.ptakasa.com

93 No. Name of Equipment 28. Mechatronics Project Trainer

Type IEG 3103

Quantity 1 Set

Please Contact

Price Picture

Features: • Training equipment for national technical conference, mechatronics 2,4,6 •Using pneumatic, electron, electricity components applied to industrial field •Fostering application technique as consisting of various control elements •Possible to mount PLC with Multi PLC system •Components are equipped to control the machine, electricity, electron elements •Providing electronic statistical textbook and library for 3D assembly simulation •Possible to attach/detach the part for actual assembly after simulation •Attach the I/O terminal to each module to practice with wirings Product Configuration:

www.ptakasa.com

94

www.ptakasa.com

95

www.ptakasa.com

96

www.ptakasa.com

97

www.ptakasa.com

98 No. Name of Equipment 29. ABB educational robot System

Type IEG IRB120

Quantity 1 Set

Please Contact

Price Picture

The importance of in dustrial robot Industrial robot plays a very important role on the production in various fields. Industrial robot has come into greater prominence in recent years as it takes care of hard work and operates in various fields. Application of robot is an essential element especially for quality improvement as well as decrease in product loss, and it leads to manufacturers’competitiveness. It is true that most of manufactures are hiring skilled manpower e specializing in robots to increase their competitiveness. ABB educational robot package Robot educational programs are needed more than ever in colleges and schools, and it is necessary to provide those programs to go into the robot automation industrial field and to ensure the competitiveness. Therefore, we educate the concept, programming and operation principle of robot and provide one package with miniaturized robot. This can make you understand overall automated system needed on the industrial field as well as robot technology education. It also develops the operation and the management ability of the robot automation system more effectively. Application areas for robot Education areas through package  Operation principle of industrial robot  Composition and control principle of industrial robot automation  Design for work area and system control with robot  ABB robot programming by using offline programming software RobotStudio  Understand safety, maintenance and risk elements when working with robot

www.ptakasa.com

99 RobotStudio, ABB Simulation & Offline Programming:  RobotStudio which is ABB Simulation, Offline Programming Software is actual Simulation Software of robot application that students actually practice in class  Possible for 50 users to use RobotStudio ata nytime, anywhere simultaneously as provided 50 User licenses

ABB Automation Application Trainer:

www.ptakasa.com

100

www.ptakasa.com

101 No. Name of Equipment 30. 6 Axis Multi Joint Robot Training System

Type IEG 2211

Quantity 1 Set

Please Contact

Price Picture

Features: •Possible to practice assembling fuel cell with advanced 6 axis multi joint robot •Possible to practice integrated system consisting of 2X3 storage for storing fuel cell Cover(+),(-), the supply magazine providing fuel cell, conveyor for fuel cell transfer, sensor section for cell inspection, assembly line, storage, and etc. •Multi joint robot is used for practicing basic robot program, and index module control for transfer & storage and assembly process control for integrated fuel cell by teaching the position •Possible to practice exterior I/O control of robot with program as well as actual wiring by using basic I/O of robot Specification: Fuel Cell Materials for Robot Assembling Work 1. Stack Cover (+) : 1 piece 1) + connector 2) Embossed Hole for Hydrogen input 3) Hole for Bolt 2. Stack Cover (-) : 1 piece 1) - connector 2) Embossed Hole for gas exhaust 3) Hole with nut 3. Stackable Fuel cell : 3 pieces 1) Hydrogen Fuel Cell 2) Transparency structure 3) Hole for Bolt

www.ptakasa.com

102 Warehouse for Fuel Cell Cover : 1 set 1. Supply Magazine for hydrogen fuel cell materials 1) Storage Capacity for Hydrogen Fuel cells : 9 sets 2) Material detecting Sensor 3) Pneumatic cylinder 2. Fuel cell Cover storage 1) 2X3 storage using AL Profile 2) Possible structure to store the fuel cells and deliver using robot 3) The bottom of Stack Cover loads (+) 3, the top of Stack Cover loads (-) 3 3. Conveyor unit 1) Test the anode of Cell using proximity sensor while transfer the fuel cell 2) Conveyor system : 1EA - Size: 300(L) x 50(W) x 100(H) mm - Material : Poly urethane 2T, width 50mm, Black color - Structure : Endless adhesion - Power roller: 1EA - Idle roller : 1EA - Roller : 1EA 3) Gear motor - DC 24V, 3000rpm - Reduction ration over 100:1 4. Fuel cell assembly station 1) Possible to assemble 3 Cells and Stack Cover (+),(-) 2) Provide Stack Cover(+) and load 3 Cells after transferring Stack Cover(-) by robot 3) Provide bolts and fasten 4bolts using robot 4) Possible to assemble the Stack Cover and Cell by using magazine 5) Completely assembled fuel cell can be loaded into warehouse 5. Warehouse storage capacity 1)Storage for the completely assembled fuel cell

www.ptakasa.com

103 6 Axis Multi Joint Robot with Controller : 1 set 1. Body 1) Moving type: vertical articulated type 2) Number of axis controlled: 6 3) Reach : 580mm 4) Payload : 3 kg 5) Armload : 0.3 kg 6) Integrated signal supply : 10 signals on wrist 7) Integrated air supply : 4 air on wrist (5 bar) 8) Position repeatability : 0.01 mm 9) Robot mounting Any : angle 10) Degree of protection : IP30 11) Axis movements(MAX Speed) - Axis 1 : +165° to -165° 250°/s - Axis 2 : +110° to -110° 250°/s - Axis 3 : +70° to -90° 250°/s - Axis 4 : +160° to -160° 320°/s - Axis 5 : +120° to -120° 320°/s - Axis 6 : +400° to -400° 420°/s 2. Robot Controller 1) Controller hardware - Multi-processor system - PCI bus - Flash disk mass memory - Energy back-up power failure handling - USB memory interface 2) Control software - Well proven real-time OS - High-level RAPID programming language - PC-DOS file ofrmat Preloaded software, available on DVD - Extensive functionality set, see separate - Robotware data sheet 3. Control panel : On cabinet or remote

www.ptakasa.com

104 4. Flex Pendant 1) Weight 1 kg 2) Graphical color touch screen Joystick 3) Emergency stop 4) Support for right- and left hand operators 5) USB Memory support 5. Machine Interface 1) Inputs/outputs : Standard 16/16 (up to 2200) 2) Digital: 24V DC or erlay signals 3) Analogue: 2 x 0-10V, 3x ±10V, 1x4-20mA 4) Serial channel: 1 x RS 232 (RS422 with adaptor) 5) Network: Ethernet (10/100 Mbits per second) 6) Two channels: Service and LAN 7) Field bus Master: DeviceNetTM, PROFINET, PROFIBUS DP, EtherneTtM/IP 8) Field bus Slave: PROFINET (8192 I/O signals), PROFIBUS DP, E t h e rnet/IPTM Allen-Bradley Remote I/O, CC-link 6. Sensor Interfaces 1) Search stop with automatic program shift Seam/contour tracking 2) Conveyor tracking 3) Machine vision 4) Force control 7. Educational Software Package 1) Multitasking 2) Sensor Interface 3) Production Manager 4) Advanced shape tuning 5) World Zones 6) Independent Axis 7) Path Recovery 8) Path Offset 9) Soft Move 10) Collision Detection

11) FTP and NFS client 12) Flex Pendant Interface 8. Working Table 1) Dimension : 1200(W)*1200(D)*1800(H) mm 2) Transparency front fence with safety materials 3) Transparency side fence with safety materials 4) Slot interval of aluminum base plate : 25mm 5) 4 wheels with locking function 6) I/O Terminal - Terminal for 6 Axis Robot interface - 16 inputs, 16 outputs - Digital I/O interface through D-sub Connector 7) Acrylic panel for robot teaching practice

www.ptakasa.com

105 Auto Robot Hand and Tool Changer : 1 set : Automatic tool changer makes 6 axis multi joint robot can changes grippers and automatic screw driver for specific working. 1. Master Plate - 1set 1) Ball locking type 2) Provides 2 air supplying ports and electric power supplying contacts 3) Tool Plates can be automatically assemble and disassemble on Master Plate 2. Tool Plate - 3sa/set 1) End-Effector adaptor module 2) provide the port delivering the electronic signal as well as pneumatic form robot 3) Design of mechanical Fall-Safe from which Tool Plate is not separated even if the pneumatic is blocked after jointing 3. Tool Changer 1) Payload : 49N (5Kg) 2) Accuracy : ± 0.01mm 3) Clamping power : 612.5N (under air pressure 0.49MPa) 4) Materials for Master Plate : Stainless steel Materials for tool plate (Alluminum) 5) Dimensions : 49mm × 48.5mm 6) Weights of Master Plate : 260g Weights of Tool Plate : 100g 7) Removal type : Ball Locking type 8) Air Service Port : 6 ports M5 size 9) Power Service terminal : 10 terminals (3A for each terminals) 4. Parallel air chuck (2 fingers) - 1set 1) Air pressure : 0.1 ~ 0.7MPa 2) Accuracy : ±0.01mm 3) oilless 4) Double acting type 5) Internal diameter of cylinder: 16mm 6) External gripper power: 34N 7) Internal gripper power: 45N 8) Stroke: 6mm 9) Finger set for transferring pencil and cell for robot teaching 10) Connecting wiring with bracket Tool Plate is applied

5. Parallel air chuck (3 fingers) - 1set 1) Air pressure : 0.1 ~ 0.6MPa 2) Accuracy : ±0.01mm 3) oilless 4) Double acting type 5) nternal diameter of cylinder: 10mm 6) External gripper power: 25N 7) Internal gripper power: 28N 8) Stroke: 4mm 9) Finger set for transferring bolt and work piece 10) Connecting wiring with bracket Tool Plate is applied 6. Automatic screw driver - 1set 1) Available screw size : M2.6 ~ M4 2) Torque : 4.0 ~ 18.0 kgf/cm 3) Weight : 500g 4) Speed : 1000RPM 5) Connecting wiring with bracket Tool Plate is applied

www.ptakasa.com

106 No. Name of Equipment 31. PLC Application Trainer

Type IEG 3163

Quantity 1 Set

Please Contact

Price Picture

www.ptakasa.com

107

www.ptakasa.com

108

www.ptakasa.com

109

www.ptakasa.com

110

www.ptakasa.com

111

www.ptakasa.com

112 No. Name of Equipment 32. Displacement Sensor Trainer

Type IEG 3250

Quantity 1 Set

Please Contact

Price Picture

Features: •Practice all kinds of motors and sensor by using industrial sensors •Practice the change and the measuerment of displacement sensor by using AD Converter •Practice DC motor, Step motor, 3 phases induction generator AC Servo motor control •Consist of sensor for environmental measure, distance measurement (laser, ultrasonic waves, magnetic sensor), rpm measurement and digital sensor •Possible to practice automated sensor control with PLC •Possible to practice sensor measurement with DAQ •Possible to practice sensor application with breadboard •Possible to control clock wise/counterclockwise direction, speed, and 485 communication by Motor Control Module

www.ptakasa.com

113

www.ptakasa.com

114

www.ptakasa.com

115

www.ptakasa.com

116 No. Name of Equipment 33. Proximity Sensor Trainer

Type IEG 3230-01

Quantity 1 Set

Please Contact

Price Picture

•Proximity : capacitance type sensor (M18,M30), induction type proximity sensor (M8, M12), spatter induction type sensor (M12), prismatic shape sensor (□17mm, □50mm), Flat type sensor (□25mm) •Photoelectric : direct reflection type photosensor, mirror reflection type photosensor, transmission type sensor light projector, BGS reflection type photosensor •Magnet(Reed) : Reed Switch(cylinder) •Photo Micro : transmission type photomicrosensor (T,L,K,U Type)

34. Photoelectric & Optical Fiber Sensor Trainer

IEG 332002

1 Set

Picture

•Optical Fiber : optical fiber for light transmission type sensor, basic type of optical fiber amp, external synchronous input type of optical fiber amp, Remote sensitivity setup type of optical fiber amp •Photoelectric : transmission type photosensor light projector, transmission photosensor (M18), mirro reflection type photosensor, mirro reflection type photosensor(M18), direct reflection type phtosensor

www.ptakasa.com

117 No. Name of Equipment 35. Switch & Lamp Trainer

Type IEG 3320-03

Quantity 1 Set

Please Contact

Price Picture

•Lamp : red round lamp, green square lamp, yellow rectangle lamp (8 Ф,12 Ф,16 Ф / switch to hold the push-butot n) •Switch : red round switch, green square switch, yellow rectangle switch (8 Ф,12 Ф,16 Ф / switch to hold the pushbutton), 2 level selector switch, emergency switch, key built-in selector switch, dimmer switch (push-button(return type), push-button(holding type), emergency, selector, push-button(square shape), pilot lamp, plunger type (short plunger, plunger, roller), lever type (hinge, roller,bending, one direction), push foothold, Sum Rotary •Signal Lamp, Buzzer

36. Tower Lamp & Limit Switch Trainer

IEG 3320-04

1 Set

Picture

•Tower Lamp : 4 level tower lamp, toggle switch (red, yellow, green, blue) •집합형 LED Lamp(10단) •Limit Switch : top plunger type limit switch, roller plunger type limit switch, ball plunger ytpe limit switch, roller lever type limit switch, variable roller lever type limit switch, variable rod lever type limit switch, side roller plunger type limit switch, 4level self-hold type cam switch, 3level reset type cam switch

www.ptakasa.com

118 No. Name of Equipment 37. Encoder Trainer

Type IEG 3320-05

Quantity 1 Set

Please Contact

Price Picture

•Linear Encoder : linear encoder + counter, reset switch, LED (Phase A,B,Z) •Rotary Encoder : absolute-type rotary encoder, absolutetype BCD rotary encoder, hollow type rotary encoder •Rotary Encoder (Haddle Type): handle type encoder, digital counter, reset switch, LED (Phase A,B,Z)

38. Area Sensor & Linear Sensor Trainer

IEG 3320-06

1 Set

Picture

•Area Sensor : transmission type area sensor •Linear Sensor : linear sensor, linear LVDT •Ampere Meter : 4Digit, 2 Ф terminal x 2EA (DC4~20mA) •Volt Meter : 4Digit, 2 Ф terminal x 2EA (DC1~10V)

www.ptakasa.com

119 No. Name of Equipment 39. Sensor Table

Type IEG 3310-08

Quantity 1 Set

Please Contact

Price Picture

www.ptakasa.com

120 No. Name of Equipment 40. Total Flexible Manufacturing System

Type IEG 3420

Quantity 1 Set

Please Contact

Price Picture

Features: •Intelligent Conveyor System •Robot Control System •PLC & HMI System •Vision Control System •System Integration

www.ptakasa.com

121

Pneumatics & Hydraulics No. Name of Equipment 1. Pneumatic trainer

Type IEG 4000

Quantity 1 Set

Please Contact

Price Picture

Features: •Suitable for education to improve an automation job ability based on real industry fields and Certification Training Device relating to pneumatic •Safer and faster composition of pneumatic circuits (Vertical and horizontal installation is possible) on a profile working board is available through a hand-lever fixing device with one-touch cam type •Composed with various electrical and electronic control units, all sorts of sensors and pneumatic components •Composed with a pneumatic automation system by basic and application steps •Provide pneumatic simulation software for education purpose •Possible to customize extra pneumatic valve such as Combination Valve Specification:  IEG 4000-102 Silent Air Compressor •Input Voltage : AC 220V •Electric Power : 3/4HP •Discharge Pressure : 8kg f/cm² •Tank Capacity: More than 20ℓ •Quantity : 1 EA

www.ptakasa.com

122  IEG 4000-1 / IEG 4000-2 Pneumatics Working Table Set (Single/Both Sided) •Working Table - Table size : 1400(W)×1600(H)×800(D)mm - Components Cabinet: A three stages or four stages type’s drawer is equipped with a table and it is movable and detachable, and a cushion board to fix components is inside the drawer - Movable wheels are equipped •Working Board - Working Board Size: 1100(W) x 760(D) mm (Single: 1 EA / Double: 2 EA) - Aluminum Profile Type - Slot Interval: 25mm - Slot Quantity: 29Line - Possible to be vertically and horizontally installed through a cam type’s tightening - Sub-profile panel is attached for electric control and module installation  IEG 4000-6 Double Acting Cylinder (single: 1 EA / Double: 2 EA) •Built in sensor magnet and Air cushion •Operating pressure: 0.5~10kgf/㎠  IEG 4000-5 Single Acting Cylinder •Tube inside diameter : 25 Ф / sotrke distance : more than •Built in sensor magnet and rubber cushion 125mm •Operating pressure: 0.5~10kgf/㎠ •Forward movement output: 30.1kg f(294N) •Tube inside diameter : 25Ф/ storke distance : more than 125mm •Cylinder output / resetting force (based on 6bar): •Backward movement output: 25.2kg f(247N) 25.3kg f(248N)/2.5kg f(25N) •Hand lever : one-touch method •Hand lever : one-touch method •Quantity: 1EA •Quantity : 1EA

www.ptakasa.com

123  IEG 4000-7 Double Acting Cylinder (Flow control valve) •Built in sensor magnet and rubber cushion •Operating pressure: 0.5~10kgf/㎠ •Cylinder inside diameter : 25 mm / sotrke distance : more than 125mm •Forward movement output: 30.1kg f(294N) •Backward movement output: 25.2kg f(247N) •Valve mounted to control the rate of flow •Hand lever : one-touch method •Quantity: 1EA  IEG 4000-35 Single Acting Cylinder •Built in sensor magnet and rubber cushion •Operating pressure: 0.5~10kgf/㎠ •Tube inside diameter : 25 Ф / sotrke distance : more than 75mm •Cylinder output / resetting force (based on 6bar): 25.3kg f(248N)/2.5kg f(25N) •Hand lever : one-touch method •Quantity: 1EA  IEG 4000-4 Air Distributor •Operating pressure: -1 ~10 kgf/㎠ •Output connector port : more than 8EA (self locking type) •Input connection port : 1EA •Hand lever : one-touch method •Quantity : 1EA



IEG 4000-88 Double Acting Cylinder (cushion equipped, proximity switch mounted) •Built in sensor magnet and rubber cushion •Operating pressure: 0.5~10kgf/㎠ •Cylinder inside diameter : 25 mm / sotrke distance : more than 125mm •Forward movement output: 30.1kg f(294N) •Backward movement output: 25.2kg f(247N) •Electricity proximity switch : 2EA •Hand lever : one-touch method •Quantity: 1EA  IEG 4000-3 Air Service Unit •Consists of air Filter, Regulator, Lubricator, Shut-Off S.W as mounted •Operating pressure: 0~10 kgf/㎠ •Set pressure: 0.5~7 kgf/㎠ •Pressure gauge (W/Limit Indicator): 0~10.0 kgf/㎠ •Filter’s filtration : Less than 5㎛ / Automatic Drain Valve •Lubricator : Turbine oil class 1 (ISO VG#32) •Hand lever : one-touch method

www.ptakasa.com

124  IEG 4000-8 Pressure Control valve •Operating pressure: 0 ~10 kgf/㎠ •Set pressure range: 0.5~8.5 kgf/㎠ •Guaranteed pressure: 15 kgf/㎠ •Structure : Relief type •Pressure gauge (W/Limit Indicator): 0~10.0 kgf/㎠ •Hand lever : one-touch method •Quantity : 1EA  IEG 4000-9 Time delay valve (N/C) •Operating pressure: 0 ~10 kgf/㎠ •Delay interval : 1~10sec •Signal pressure: 1.5~8 kgf/㎠ •Normal close type valve •Hand lever : one-touch method •Quantity : 1EA IEG 4000-10 Time delay valve (N/O) •Operating pressure: 0 ~8.5 kgf/㎠ •Delay interval : 0.5~6sec •Signal pressure: 1.5~8 kgf/㎠ •Normal open type valve •Hand lever : one-touch method •Quantity : 1EA



IEG 4000-11 One way Flow control valve

•Operating pressure: 0.5~10 kgf/㎠ •Free flow (Out-> In) rate : 340ℓ/min •Control flow (In-> Out) rate: 250 ℓ/min •Hand lever : one-touch method •Quantity : 1EA

 IEG 4000-12 Pressure Sequence Valve •Operating pressure: 0.5~8 kgf/㎠ •Control pressure range: 01.0~8 kgf/㎠ •Spring set mounted for pressure control •Hand lever : one-touch method •Quantity : 1EA



IEG 4000-13 Quick Exhaust Valve

•Possible to make quick move when cylinder forwars/backwards •Operating pressure: 0~10 kgf/㎠ •Normal flow(P -> A)rate : 780 ℓ/min •Quick Exhaust(A -> R) rate : 890 ℓ/min •Exhaust port : Silence attachment •Hand lever : one-touch method •Quantity : 1EA

www.ptakasa.com

125 

IEG 4000-14 3/2-way 3/2-way Push Switch Valve (N/C)



IEG 4000-17 5/2-way Manual Transfer Valve

•Operating pressure: -1~10 kgf/㎠

•Operating pressure: 1.5~7 kgf/㎠

•Spring return type

•Spring return type / Direct operation valve

•Direct operation valve

•Two position selector switch

•Protrusion type Push Button

•Hand lever : one-touch method

•Normal close type

•Quantity : 1EA

•Hand lever : one-touch method •Quantity : 1EA



 IEG 4000-15 3/2-way Push Switch Valve (N/O)

IEG 4000-18 3/2-way Both Sides Roller Lever Valve

•Two way roller lever operation

•Operating pressure: -1~10 kgf/㎠

•Operating pressure: -1~10 kgf/㎠

•Spring return type

•Spring return type / Direct operation valve

•Direct operation valve

•Normal close type / left type

•Protrusion type Push Button

•Hand lever : one-touch method

•Normal open type

•Quantity : 1EA

•Hand lever : one-touch method •Quantity : 1EA

 

IEG 4000-16 3/2-way Manual Transfer Valve

•Operating pressure: -1~10 kgf/㎠ •Spring return type •Direct operation valve •Two position selector switch •Normal close type

IEG 4000-19 3/2-way One Sides Roller Lever Valve (L)

•One way roller lever operation •Operating pressure: -1~10 kgf/㎠ •Spring return type / Direct operation valve •Normal close type /l eft type •Hand lever : one-touch method •Quantity : 1EA

•Hand lever : one-touch method •Quantity : 1EA

www.ptakasa.com

126 

IEG 4000-20 3/2-way One Sides Roller Lever Valve (R)

•One way roller lever operation •Operating pressure: -1~10 kgf/㎠ •Spring return type / Direct operation valve •Normal close type/right type •Hand lever : one-touch method •Quantity : 1EA



IEG 4000-21 3/2-way Pneumatic Valve (N/C)

•Structure : Inner Pilot, spool type •Operating pressure: 1.5 ~7 kgf/㎠ •Pilot pressure : 1.5~7 kgf/㎠ •Normal close type •Piston return type / Possible for manual operation •Hand lever : one-touch method



IEG 4000-23 4/2-way Single Acting Pneumatic Valve

•Structure : Inner Pilot, spool type •Operating pressure: 1.5 ~7 kgf/㎠ •Pilot pressure : 2.0 ~7 kgf/㎠ •Piston return type / Possible for manual operation •Hand lever : one-touch method •Quantity : 1EA



IEG 4000-24 4/2-way Double Acting Pneumatic Valve

•Structure : Inner Pilot, spool type •Operating pressure: -1 ~7 kgf/㎠ •Pilot pressure : 2.0 ~7 kgf/㎠ •Double Piston return type / Possible for manual operation •Hand lever : one-touch method •Quantity : 1EA

•Quantity : 1EA

IEG 4000-22 3/2-way Pneumatic Valve (N/O) •Structure : Inner Pilot, spool type •Operating pressure: 1.5 ~7 kgf/㎠ •Pilot pressure : 1.5~7 kgf/㎠ •Normal open type •Piston return type / Possible for manual operation •Hand lever : one-touch method



IEG 4000-25 5/2-way Single Acting Pneumatic Valve

•Structure : Inner Pilot, spool type •Operating pressure: 1.5 ~7 kgf/㎠ •Pilot pressure : 2.0 ~7 kgf/㎠ •Piston return type / Possible for manual operation •Hand lever : one-touch method •Quantity : 1EA

•Quantity : 1EA

www.ptakasa.com

127 

IEG 4000-26 5/2-way Double Acting Pneumatic Valve

IEG 4000-29 Check Valve

•Structure : Inner Pilot, spool type

•Operating pressure: 0.2 ~10 kgf/㎠

•Operating pressure: -1 ~7 kgf/㎠

•Cracking pressure : 0.2 kgf/㎠

•Pilot pressure : 1 ~7 kgf/㎠

•Hand lever : one-touch method

•Double Piston return type / Possible for manual operation

•Quantity : 1EA

•Hand lever : one-touch method •Quantity : 1EA



IEG 4000-27 AND Valve

•Operating pressure: 0.5 ~9.9 kgf/㎠ •Low pressure preferable 2 pressure valve •Normal flow (X,Y -> A) : 480Nℓ/min •Implement AND Logic •Hand lever : one-touch method •Quantity : 1EA



IEG 4000-28 OR Valve

•Operating pressure: 0.5 ~9.9 kgf/㎠ •High pressure preferable shuttle valve •Normal flow (X,Y -> A) : 700Nℓ/min •Implement OR Logic •Hand lever : one-touch method •Quantity : 1EA



IEG 4000-30 Pressure Gauge

•Indicating range : 0 ~ 10kg f/cm² •Display : 42.5ø •Bourdon tube type / Direct pressure display •Input connector port : 2 EA (Built in check valve) •Hand lever : one-touch method •Quantity : 1EA



IEG 4000-37 3/2-way Single Acting Solenoid Valve (N/C)

•Operating pressure: 1.5 ~7 kgf/㎠ •Response time : Less than 30ms / Normal close ytpe •Piston return type / Low consumer electric power :0.35W(24V DC) •Solenoid coil : built in non polar Lamp and surge voltage protective circuit •Integral 4mm socket-coil / Can be operated manually (Non-Lock Push type) •Hand lever : one-touch method •Quantity : 1EA

www.ptakasa.com

128 

IEG 4000-38 5/2-way Single Acting Solenoid Valve



IEG 4000-40 Pneumatic - Electric Signal Converter

•Operating pressure: 1.5 ~7 kgf/㎠

•Operating pressure: 1 ~7 kgf/㎠

•Response time : Less than 26ms / Piston return type

•Set pressure range : 1 ~6 kgf/㎠

•Low consumer electric power :0.35W(24V DC)

•Set pressure adjustable and indication lamp

•Solenoid coil : built in non polar Lamp and surge voltage protective circuit

mounted

•Integral 4mm socket-coil / Can be operated manually (Non-Lock Push type)

•Contact composition : 1a

•Hand lever : one-touch method

•Switch rating : DC 24V

•Quantity : 1EA

•Hand lever : one-touch method •Quantity : 1EA



IEG 4000-39 5/2-way Double Acting Solenoid Valve



IEG 4000-92 3/2-way Single Acting Solenoid Valve (N/O)

•Operating pressure: 1 ~7 kgf/㎠

•Operating pressure: 1.5 ~7 kgf/㎠

•Response time : Less than 22ms

•Response time : Less than 30ms / Normal open type

•Low consumer electric power :0.35W(24V DC)

•Piston return type

•Solenoid coil : built in non polar Lamp and surge voltage protective circuit

•Low consumer electric power :0.35W(24V DC)

•Integral 4mm socket-coil

•Solenoid coil : built in non polar Lamp and surge voltage protective circuit

•Can be operated manually (Non-Lock Push type)

•Integral 4mm socket-coil / Can be operated manually (Non-Lock Push type)

•Hand lever : one-touch method

•Hand lever : one-touch method

•Quantity : 1EA

•Quantity : 1EA

www.ptakasa.com

129 

IEG 4000-93 3/2-way Double Acting Solenoid Valve



IEG 4000-97 5/3-way Double Acting Solenoid Valve (ABR)

•Operating pressure: 1.0 ~7.1 kgf/㎠

•Operating pressure: 2 ~7 kgf/㎠

•Response time : Less than 22ms

•Response time : Less than 38ms / Exhaust center type

•Low consumer electric power :0.35W(24V DC, 41mA)

•Low consumer electric power :0.35W(24V DC)

•Solenoid coil : built in non polar Lamp and surge voltage protective circuit

•Solenoid coil : built in non polar Lamp and surge voltage protective circuit

•Integral 4mm socket-coil / Can be operated manually (Non-Lock Push type)

•Integral 4mm socket-coil / Can be operated manually (Non-Lock Push type)

•Hand lever : one-touch method

•Hand lever : one-touch method

•Quantity : 1EA

•Quantity : 1EA





IEG 4000-96 5/3-way Double Acting Solenoid Valve (All Block)

IEG 4000-98 5/3-way Double Acting Solenoid Valve (PAB)

•Operating pressure: 2 ~7 kgf/㎠

•Operating pressure: 2 ~7 kgf/㎠

•Response time : Less than 38ms / Close center type

•Response time : Less than 38ms / Pressure center type

•Low consumer electric power :0.35W(24V DC)

•Low consumer electric power :0.35W(24V DC)

•Solenoid coil : built in non polar Lamp and surge voltage protective circuit

•Solenoid coil : built in non polar Lamp and surge voltage protective circuit

•Integral 4mm socket-coil / Can be operated manually (Non-Lock Push type)

•Integral 4mm socket-coil / Can be operated manually (Non-Lock Push type)

•Hand lever : one-touch method

•Hand lever : one-touch method

•Quantity : 1EA

•Quantity : 1EA

www.ptakasa.com

130 

IEG 4000-100 5/3-way Single Acting Solenoid Combination Valve



IEG 4000-49 Photo Sensor

•5/2-Way Single Solenoid Valve : 2EA

•Sensing distance : Maximum 100mm

•Operating pressure: 1.5 ~7 kgf/㎠

•Power : DC 12~25V ± 10%

•Response time : Less than 26ms / Piston Return

•Current consumption : Less than 40mA

•Low consumer electric power :0.35W(24V DC)

•Output : NPN Open Collector / Response time : Less than 3ms

•Solenoid coil : built in non polar Lamp and surge voltage protective circuit

•Rated output : current 100mA / voltage (less than 30V)

•Integral 4mm socket-coil / Can be operated manually (Non-Lock Push type)

•Possible to change (atach/detach) it vertically and horizontally at profile using

•Hand lever : one-touch method

lever and cam ※Select NPN/ PNP Type

•Quantity : 1EA



IEG 4000-50 Capacitive Sensor

•Sensing distance : 8mm



IEG 4000-101 5/3-way Double Acting Solenoid Combination Valve

•Power : DC 10~30V

•5/2-Way Single Solenoid Valve : 2EA

•Current consumption : Less than 15 mA

•Operating pressure: 1.0 ~7 kgf/㎠

•Load current : Less than 200 mA

•Piston Return

•Output : NPN Open Collector / Response time : Less than 3ms

•Low consumer electric power :0.35W(24V DC)

•Possible to change (atach/detach) it vertically and horizontally at profile using

•Solenoid coil : built in non polar Lamp and surge voltage

lever and cam

protective circuit

•Quantity : 1EA

•Integral 4mm socket-coil

※Select NPN/ PNP Type

•Can be operated manually (Non-Lock Push type) •Hand lever : one-touch method •Quantity : 1EA

www.ptakasa.com

131 

IEG 4000-51 High-frequency oscillator-typed proximity Sensor (NPN)



IEG 4000-54 Limit Switch (R)

•Sensing distance : 8mm

•Roller lever operational type

•Power : DC 10~30V

•Contact composition : 1c

•Current consumption : 10 mA

•Contact rating : DC 24V 5A

•Load current : Less than 200 mA (R Load)

•Possible to change (atach/detach) it vertically and

•Possible to change (atach/detach) it vertically and horizontally

horizontally

at profile using lever and cam

at profile using lever and cam

•Quantity : 1EA

•Quantity : 1EA



IEG 4000-55 Power Supply

IEG 4000-52 High-frequency oscillator-typed proximity Sensor (PNP)

•Sensing distance : 8mm

•Input voltage : AC 220V/50~60Hz

•Power : DC 10~30V

•Output : more than 24V 5A

•Current consumption : 10 mA

•Built in over current protection circuit

•Load current : Less than 200 mA (R Load)

•Buzzer sounds at the occurrence of

•Response frequency : 100Hz

overload

•Diameter of detected side : 30mm

•Possible to change (atach/detach) it

•Possible to change (attach/detach) it vertically and horizontally

vertically and horizontally

at profile using lever and cam

at profile using lever and cam

•Quantity : 1EA

•Quantity : 1EA





IEG 4000-53 Limit Switch (L)

IEG 4000-67 4/3-way Manual Valve (All Block)

•Roller lever operational type

•Structure : direct operational, spool type

•Contact composition : 1c

•Close center type

•Contact rating : DC 24V 5A

•Operating pressure : 0~ 8.0 kgf/㎠

•Possible to change (atach/detach) it vertically and

•Hand lever : one-touch method

horizontally

•Quantity : 1EA

at profile using lever and cam •Quantity : 1EA

www.ptakasa.com

132 

IEG 4000-64 5/3-way Double Pneumatic Valve (All Block)



•Structure : Inner Pilot, Spool type

IEG 4000-68 4/3-way Manual Valve (ABR)

•close center type

•Structure : direct operational, spool type

•Operating pressure : 1.0~ 10 kgf/㎠

•Exhaust center type

•Pilot pressure : 1.0 ~ 7 kgf/㎠

•Operating pressure : 0~ 8.0 kgf/㎠

•Double pilot operation / can be operated manually

•Hand lever : one-touch method

•Hand lever : one-touch method

•Quantity : 1EA

•Quantity : 1EA





IEG 4000-65 5/3-way Double Pneumatic Valve (ABR)

IEG 4000-77 Vacuum Valve with Vacuum Cup

•Operating pressure : 1.5 ~ 10kg f/cm²

•Structure : Inner Pilot, Spool type, exhaust center type

•Vacuum formation pressure (105kgf/cm²) : -0.7kg f/cm²

•close center type

•Theory of vacuum generating : Ventury theory

•Operating pressure : 1.0~ 10 kgf/㎠

•Air Consumption : 15Nℓ/min

•Pilot pressure : 1.0 ~ 7 kgf/㎠

•Suction cup diameter : 30mm (Bufter mounted)

•Double pilot operation / can be operated manually

•Hand lever : one-touch method

•Hand lever : one-touch method

•Quantity : 1 EA

•Quantity : 1EA

IEG 4000-66 5/3-way Double Pneumatic Valve (PAB) •Structure : Inner Pilot, Spool type, exhaust center type •Operating pressure : 1.0~ 10 kgf/㎠ •Pilot pressure : 1.0 ~ 7 kgf/㎠ •Double pilot operation / can be operated manually



IEG 4000-83 Pilot Check Valve

•Operating pressure : 2 ~ 10kg f/cm²

•Hand lever : one-touch method

•Indirect operation type

•Quantity : 1EA

•Normal flow (5.5bar) rate : 15Nℓ/min •Use : intermediate stop and fall prevention

of

the cylinder •Hand lever : one-touch method •Quantity : 1 EA

www.ptakasa.com

133 

IEG 4000-78 Vacuum Pressure Gauge

IEG 4000-99 Pressure Switch

•Indicating range : -1 ~ 0kg f/cm² (760 ~ 0mmHg)

•Operating pressure : 0.5 ~ 8kg f/cm²

•Indicator's diameter : 40ø

•Set pressure range : 1 ~ 7.0kg f/cm²

•Vacuum pressure display

•Set pressure adjustable and indication lamp

•Hand lever : one-touch method

mounted

•Quantity : 1 EA

•Contact composition : 1a, 1b •Rated switch : DC 30V, 4A •Quantity : 1 EA



 IEG 4000-80 Low Pressure Control Valve

IEG 4000-61 Double Load Cylinder

•Built in sensor magnet and rubber cushion

•Operating pressure : 10kg f/cm²

•Operating pressure : 0.5 ~ 9.9kg f/cm²

•Set pressure range : 0 ~ 2kg f/cm²

•Cylinder inside Diameter : 25mm / Stroke distance : 125mm

•Structure : Relief Type

•Forward movement output : 29.5kg f(290N)

•Pressure Gauge (W/Limit Indicator) : 0 ~ 2.0 kg f/cm²

•Backward movement output : 24.7kg f(242N)

•Hand lever : one-touch method

•Flow control valve (Attachable type)

•Quantity : 1 EA

•Hand lever : one-touch method



•Quantity : 1 EA

IEG 4000-82 Pressure Control Valve

•Operating pressure : 0 ~ 10kg f/cm² •Set pressure range : 1.0 ~ 9kg f/cm²

IEG 4000-74 Pneumatic Indicator Lamp

•Structure : Relief Type

•Operating pressure : 1 ~ 8kg f/cm²

•Built in check valve

•Lamp color : Red

•Hand lever : one-touch method

•Lamp diameter : 22mm

•Quantity : 1 EA

•Hand lever : one-touch method •Quantity : 1 EA

www.ptakasa.com

134 

IEG 4000-62 Rodless Cylinder



IEG 4000-75 OR Block

•Built in sensor magnet and rubber cushion

•Operating pressure : 1~9.9 kgf/㎠

•Operating pressure: 2.0~7.0 kgf/㎠

•High pressure priority type shuttle valve

•Cylinder inside diameter : 16mm / Sotrke distance :

•Normal flow (X,Y -> A) arte : 90Nℓ /min

200mm

•OR Valve : 3EA

•Operating system : magnetic type

•Hand lever : one-touch method

•Flow control valve (Attachable type)

•Quantity : 1EA

•Quantity : 1EA



IEG 4000-63 Rotary Cylinder



IEG 4000-76 AND Block

•Operating pressure : 1.5 ~ 10kg f/cm²

•Operating pressure : 1~9.9 kgf/㎠

•Rotary angle : 0 ~ 180˚

•High pressure priority type shuttle valve

•Flow control valve and rotary sensor plate as mounted

•Normal flow (X,Y -> A) arte : 90Nℓ /min

•Hand lever : one-touch method

•OR Valve : 3EA

•Quantity : 1 EA

•Hand lever : one-touch method



•Quantity : 1EA

IEG 4000-73 Pneumatic Signal Counter

•Operating pressure : 1.5 ~ 10kg f/cm² •Count Display : 5 Digits •Rest type : Pneumatic and manual •Hand lever : one-touch method •Quantity : 1 EA



IEG 4000-85 Back Pressure Sensor

•Operating pressure : 0 ~ 9.9kg f/cm² •Normal flow rate : 90Nℓ/min •Hand lever : one-touch method •Quantity : 1 EA

www.ptakasa.com

135 

IEG 4000-79 Low Pressure Pneumatic Sensor

IEG 4000-86 Stepper Module A

•Non contacting pressure sensor

•Operating pressure : 2 ~ 8kg f/cm²

•Operating pressure : 0.1 ~ 9.9kg f/cm²

•Poppet valve type

•Supplied pressure range : 0.1 ~ 0.25kg f/cm²

•AND/OR gate combination

•Sensing distance : 2 ~ 5mm

•Built in penumatic lamp

•Hand lever : one-touch method

•A-A-A-A type (4a)

•Quantity : 1 EA

•Hand lever : one-touch method •Quantity : 1 EA

IEG 4000-87 Stepper module B •Operating pressure : 2~8



IEG 4000-81 Pneumatic Pressure Amp.

•Poppet valve type/ built in pneumatic

•Non lubrication compressed air

display lamp

•Operating pressure : 2 ~ 8.5kg f/cm²

•A-A-A-B type (3a+1b)

•Px supplied pressure range : 0.1 ~ 0.25kg f/cm²

•Hand lever : one-touch method

•a Supplied pressure range : 0.0005 ~ 0.2kg f/cm²

•Quantity : 1EA

•Maximum oerating frequency : 10Hz



•Hand lever : one-touch method

•Timer : 2EA

•Quantity : 1 EA

•Contact composition : 2a,2b/ 1EA

IEG 4000-42 Digital Time Relay Unit

•Input voltage : DC 24V / Delay Timer : 0.5~10sec



•Type of operation : Time ON Delay

IEG 4000-84 Air Tank

•Tank Capacity : 0.5 ℓ •Operating pressure : 0~10 kgf/㎠ •Input connector port (Built in check valve) :2EA •Hand lever : one-touch method •Quantity : 1EA

•Auxiliary power terminal : +Terminal(6EA), -Terminal(6EA) •Injection cases that are able to extend side frame on insulation box •Possible to change(attach/detach) it vertically and horizontally at profile using lever and cam •Quantity : 1EA

www.ptakasa.com

136 IEG 4000-89 Air Chuck



•Operating pressure : 1~9.9 kgf/㎠

•Contact composition : 1a,1b

•Cylinder internal diameter : 20mm

•Input voltage : DC 24V, Built in protection circuit

•Operating system: Link & Lever

•Output contact : AC250V 3A (when resistance is on load)

•Rotary angle : -5° ~ +20°

•Electro signal, manually reset / Counter

•Output when cylinder backwards : 24.7kgf(242N)

function : Forward, Backward

•Electricity proximity switch and flow control valve mounted

•Counting signal : signal for contact/non-

•Quantity : 1EA

contact point

IEG 4000-43 Digital Counter Unit

•Injection cases that are able to extend side



IEG 4000-41 3Fold Relay Unit

frame on insulation box

•Relay : 3EA

•Possible to change(attach/detach) it

•Contact composition : 4c/ 1EA

vertically and horizontally

•Contact rating : DC 24V 3A / Input ovltage : DC 24V

at profile using lever and cam

•Auxiliary power terminal : +Terminal(6EA), -Terminal(6EA)

•Quantity : 1EA

•Injection cases that are able to extend side frame on insulation box •Possible to change(attach/detach) it vertically and horizontally



at profile using lever and cam

•Push button with red lock function

•Quantity : 1EA

•Contact composition : 1a � 1b

IEG 4000-46 Emergency Switch Unit

•Rated current : DC 24V 5A •Built in insulation box •Quantity : 1EA

www.ptakasa.com

137 

IEG 4000-44 Electro Signal Switch Unit A



IEG 4000- 47A Electrical distribution Unit

•Return type switch: 2 EA (equipped)

•+,- Contact : 2 circuits with each 6 ports on the top and the bottom

•Lock type switch: 1 EA (equipped)

•Contact for load : composed of 8 lines (Red/Green Lamp display)

•DC 24V Lamp (Red, Green, Yellow)

•Possible to install vertically and horizontally with tightening method

•Contact composition: 2a, 2b, 2c/ 1EA

•Quantity : 1EA

•Rated current: DC 24V 1.5A •Injection cases that are able to extend side frame on insulation box •Possible to change(attach/detach) it vertically and horizontally at profile using lever and cam •Quantity : 1EA



IEG 4000-45 Electro Signal Switch Unit B

•Return type switch: 1 EA (equipped) / Lock type switch: 2 EA (equipped)

•DC 24V Lamp (Red, Green, Yellow) •Contact composition: 2a, 2b, 2c/ 1EA



•Rated current: DC 24V 1.5A

•A tool for cutting the air hose

•Injection cases that are able to extend side frame on

•Quantity : 1 EA

IEG 4000-33 Hose Cutter

insulation box •Possible to change(attach/detach) it vertically and horizontally at profile using lever and cam •Quantity : 1EA

www.ptakasa.com

138 

IEG 4000-48 Buzzer & Lamp Unit



IEG 4000-34 Support Component Set

•DC 24V Buzzer: 1EA

•L-shaped fitting

•DC 24V Lamp : 4EA (Red, Green, Yellow, White)

- 1/4 : 5 EA 1/8 : 5ea

•Injection cases that are able to extend side frame on

•Straight fitting

insulation box

- 1/4 : 5 AE 1/8 : 5A E M5 : 5 AE

•Possible to change(attach/detach) it vertically and

•Quantity : 1 SET

horizontally at profile using lever and cam •Quantity : 1EA

IEG 4000-56 Connection Cable Set



•Red

IEG 4000-31 T Type Connector

- 200mm : 5 EA/500mm : 10 EA

•Operating pressure :

- 1000mm : 10 EA/1500mm : 10 EA

0-9.9kg f/cm²

•Black

•Hose diameter : Outside

- 200mm : 5 EA/500mm : 10 EA

/Inside-6mm/4mm

- 1000mm : 10 EA/1500mm : 10 EA

•Connector for 3 directional

•Blue

divergence

- 200mm : 10 EA/500mm : 10 EA

•Quantity : 1 Set

- 1000mm : 10 EA/1500mm : 5 EA



•Quantity : 1 SET

IEG 4000-32 Air Hose

•Diameter : Outside/ Inside-4ø/6ø (50m) •It is possible to select blue & black •Material : Soft nylon •Quantity : 1 EA

www.ptakasa.com

139 No. Name of Equipment 1. Hydraulic trainer

Type IEG 4100

Quantity 1 Set

Please Contact

Price Picture

Features: •Continually providing various valves to an application set in order to experience a basic practice on hydraulics and electro hydraulic and an additional practice on a high-level application hydraulic system applied to automation fields •Suitable for education to improve an automation job ability based on on-site and training device for Certification Test •Composed with various electrical and electronic control units, all sorts of sensors and hydraulic components •Composed with a hydraulic automation system by each procedure, Basis, Application, Proportion, Servo Control •Providing a hydraulic simulation system for education •Faster and safer than aluminum profile Working Board and possible to organize hydraulic circuit by using one-touch hand lever method •Possible to customize additional hydraulic valve such as Combination Valve IEG 4100-1 Hydrulics Working Table •Working Table (Single Sided) - Table Dimension : 1500(W)×1650(H)×850(D)mm - Equipped with By-pass and Drain Valve for unloading driving of pump - Components Cabinet - Movable wheels are equipped •Working Board - Board Size : 1100(W)×760(D)mm×1 EA - Aluminum Profile Type - Slot Interval: 25mm - Slot Quantity: 29Line - Possible to be vertically and horizontally installed through a cam type tightening - Sub-profile panel is attached for electric control and module installation - Install a cable cradle for circuit links (Option)

www.ptakasa.com

140 IEG 4100-2 Hydrulics Working Table

IEG 4100-4 Hydraulic Pump Unit (2HP)

•Working Table (Double Sided)

•Motor : AC220V Single phase (2HP)

-Table Dimension : 1500(W)×1650(H)×850(D)mm

•External gear type

- Equipped with By-pass and Drain Valve for unloading

•Discharge capacity : 6.3ℓ/min

driving of pump

•Tank capacity : 50ℓ (520L×420W×280H)

- Components Cabinet

•Operating pressure : 40 ~ 60 kg f/cm²

- Movable wheels are equipped

•Attachment of oil level gauge and

•Working Board

hydraulic oil thermometer

- Board Size : 1100(W)×760(D)mm×2 EA

•Block type P, T Port 2 EA

- Aluminum Profile Type

•Flowmeter connection port 30Φ

- Slot Interval: 25mm

•Applicable for both sides of hydraulic working board

- Slot Quantity: 29Line - Possible to be vertically and horizontally installed

IEG 4100-5 Overload Circuit Breaker

through a cam type tightening

•Built in power LED Lamp display

- Sub-profile panel is attached for electric control and module installation

•Maximum allowable current : 15A

- Install a cable cardle for circuit links (Option)

•Overload circuit breaker of hydraulic pump •Matrial : AL

IEG 4100-3 Hydraulic Pump Unit (1HP)

•Hand lever : one-touch method

•Motor : AC220V Single phase (1HP)

•Quantity : 1 EA

•Discharge capacity : 4.3ℓ/min •Tank capacity : 30ℓ (520L×420W×200H) •Operating pressure : 40 ~ 60 kg f/cm² •Attachment of oil level gauge and hydraulic oil thermometer •Block type P, T Port •Flowmeter connection port 30Φ •Applicable for cross section of hydraulic working board

IEG 4100-6 Flow Meter •Transparency acrylic : Maximum 2ℓ •Built in drain protection device •Check valve type coupling x 4 EA, Suction filter x 1 EA •Attachment of hand lever for Oil Drain •level attached for flux indication •Quantity : (Option)

www.ptakasa.com

141 IEG 4100-11 Transparancy Double Acting Cylinder

IEG 4100-36 Double Acting Cylinder

•Operating pressure : 60 kg f/cm²

•Operating pressure : 60 kg f/cm²

•Cylinder inside diameter : 25mm

•Cylinder inside diameter : 25mm

(stroke diameter : 150mm)

(Stroke distance : 150mm)

•Piston Rod’s diameter : 12mm

•Piston Rod’s diameter : 12mm

•Cross section ratio : 2.78:1

•Plate material : AL 5t

•Plate Material : AL 5t

•Hand lever : one-touch method

•Transparency type

•Quantity : 1 EA

•Hand lever : one-touch method •Quantity : 1 EA

IEG 4100-12 Differential Cylinder •Operating pressure : 60 kg f/cm² •Cylinder inside diameter : 25mm (Stroke distance : 150mm) •Piston Rod’s diameter : 18mm •Cross section rate : 1.93:1 •Plate material : AL 5t •Hand lever : one-touch method •Quantity : 1 EA IEG 4100-13 Single Acting Cylinder •Operating pressure : 60 kg f/cm² •Cylinder inside diameter : 25mm •Stroke diameter : 150mm •Piston Rod’s diameter : 12mm •Plate material : AL 5t •Hand lever : one-touch method •Quantity : 1 EA

IEG 4100-37 Double Acting Cylinder with Break •Operating pressure : 60 kg f/cm² •Cylinder inside diameter : 25mm (Stroke distance : 150mm) •Piston Rod’s diameter : 14mm •Plate material : AL 5t •Hand brake type •Hand lever : one-touch method •Quantity : 1 EA

IEG 4100-32 Pressure Gauge with Flow Divider •Operating pressure : 0 ~ 100kg f/cm² •Nonimal diameter : 60mm •Viscosity : 1.6% •Buffering oil : Glycerin •Distribution coupling : 4 EA •Hand lever : one-touch method •Quantity : 1 EA

www.ptakasa.com

142 IEG 4100-34 Flow Divider with 6 ports

IEG 4100-10 Hydraulic Fluids

•Operating pressure: 0~100 kgf/㎠

•Turbine oil : IS0 VG # 46

•Distribution coupling : 6EA

•Kinematic viscosity cSt (mm²/s) 40℃ : 41.4 ~ 50.6

•Hand lever : one-touch method

•Viscosity index : more than 95

•Quantity : 1EA

•Flash point : 200℃ •Pour point : -7.5℃ •Oil capacity : 20 Liter •Quantity : 1 EA

IEG 4100-35 Flow Divider with 3 Port and 2rows •Maximum operating pressure: 120 kgf/㎠ •3-way Distributor x 2EA

IEG 4100-14 2/2-Way Roller Lever Valve (N/O)

•Distribution coupling : 6EA

•Maximum operating pressure : 140kg f/cm²

•Hand lever : one-touch method

•Type of operation : mechanical

•Quantity : 1EA

•Type of return : spring return •Normally Opened •Hand lever : one-touch method •Quantity : 1 EA

IEG 4100-8 Hydraulic Hose SET •Maximum operating pressure: 120 kgf/㎠ •Radius of bending : Less than 50mm •Diameter of hose : 6mm

IEG 4100-15 2/2-Way Direction Control Valve

•600mm : 12EA , 1000mm : 6EA , 1500mm : 2EA

•Maximum operating pressure :

•Quantity : 1 SET

120kg f/cm² •Type of operation : manual lever •Type of return : spring return •Normally Closed •Valve nonimal size : NG4

www.ptakasa.com

143 IEG 4100-16 3/2-Way Direction Control Valve

IEG 4100-19 4/3-Way Direction Control Valve (By -Pass)

•Maximum operating pressure : 120kg f/cm²

•Operating pressure : 120kg f/cm²

•Type of operation : manual lever

•Type of operation : manual lever, detent function

•Type of return : spring return

•PT Junction (by pass)

•Valve nonimal size : NG4

•Valve nonimal size : NG4

•Hand lever : one-touch method

•Hand lever : one-touch method

•Quantity : 1 EA

•Quantity : 1 EA

IEG 4100-17 4/2-Way Direction Control Valve •Maximum operating pressure : 120kg f/cm² •Type of operation : manual lever

IEG 4100-20 Direct-acting Pressure Relief Valve

•Type of return : spring return

•Operating pressure : 120 kgf/㎠

•Valve nonimal size : NG4

•Hydraulic type

•Hand lever : one-touch method

•Control method : manual

•Quantity : 1 EA

•Hand lever : one-touch method •Quantity : 1EA

IEG 4100-18 4/3-Way Direction Control Valve (All Block) •Operating pressure : 120kg f/cm² •Type of operation : manual lever, detent function •PABT cut off type (all block)

IEG 4100-21 Pressure Sequence Valve

•Valve nonimal size : NG4

•Operating pressure : 120 kgf/㎠

•Hand lever : one-touch method

•Hydraulic type

•Quantity : 1 EA

•Control method : manual •Hand lever : one-touch method •Quantity : 1EA

www.ptakasa.com

144 IEG 4100-22 Counter Balance Valve

IEG 4100-39 Pressure Relief Valve

•Operating pressure : 120 kgf/㎠

•Maximum operating pressure : 120kg f/cm²

•Hydraulic type

•Normal flow rate : 10ℓ/min

•Control method : manual

•Type of operation : hydraulic, manual control

•Hand lever : one-touch method

•Valve nonimal size : NG4

•Quantity : 1EA

•Hand lever : one-touch method •Quantity : 1 EA

IEG 4100-23 3-Way Pressure Reducing Valve

IEG 4100-40 2/2-Way Roller Lever Valve

•Maximum operating pressure : 120 kgf/㎠

•Type of operation : mechanical

•Normal flow rate : 9 ℓ/min

•Type of return : spring return

•Hydraulic type

•Normally Closed

•Control method : manual

•Hand lever : one-touch method

•Hand lever : one-touch method

•Quantity : 1 EA

•Maximum operating pressure : 120kg f/cm²

•Quantity : 1EA

IEG 4100-24 Check Valve •Maximum operating pressure : 120kg f/cm² •Normal flow rate : 10ℓ/min •Type of operation : hydraulic •Cracking pressure : 2kg f/cm² •Built in non-return v/v •Rate of effective area 5:1 •Valve nonimal size : NG4

IEG 4100-41 2/2-Way Direction control Valve •Maximum operating pressure : 120kg f/cm² •Type of operation : memual lever •Type of return : spring return •Normally Opend •Valve nonimal size : NG4 •Hand lever : one-touch method •Quantity : 1 EA

•Hand lever : one-touch method •Quantity : 1 EA

www.ptakasa.com

145 IEG 4100-42 4/3-Way Direction control Valve (ABT)

IEG 4100-52 Flow Divider Valve

•Maximum operating pressure : 120kg f/cm²

•Maximum operating pressure : 120kg f/cm²

•Type of operation : manual lever, detent function

•Division/merge ratio : 50:50

•Connection : ABT Type

•Flow distribution ratio : fixed

•Valve nonimal size : NG4

•Quantity : 1 EA

•Hand lever : one-touch method •Quantity : 1 EA

IEG 4100-53 Un-loading valve IEG 4100-43 4/3-Way Direction control Valve (All Open) •Maximum operating pressure : 120kg f/cm² •Type of operation : manual lever, detent function •Connection : PABT Type (all open) •Valve nonimal size : NG4 •Hand lever : one-touch method

•Maximum operating pressure : 120kg f/cm² •Operating pressure : 60 kgf/㎠/min •Hydraulic type •Control method : manual •Hand lever : one-touch method •Quantity : 1 EA

•Quantity : 1 EA

IEG 4100-44 4/3-Way Direction control Valve (PAB) •Maximum operating pressure : 120kg f/cm² •Type of operation : manual lever, detent function •Connection : PAT Type •Valve nonimal size : NG4 •Hand lever : one-touch method •Quantity : 1 EA

IEG 4100-54 Deceleration Valve •Maximum operating pressure : 120kg f/cm² •Control flow : 0.01-4ℓ/min •Type of operation : mechanical (forward/backward roller) •Tempreature compensation type valve •Quantity : 1 EA

www.ptakasa.com

146 IEG 4100-7 Pressure Eliminator

IEG 4100-28 Shut off Valve

•Residual pressure eliminator device

•Hand Lever type

•Manual Operation type

•Maximum operating pressure : 120kg f/cm²

•Quantity : 1 EA

•Pressure shut off valve •Inline type •Coupling socket/Nipple (Built in Check Valve) •Quantity : 1 EA

IEG 4100-25 One-way Flow Control Valve •Maximum operating pressure : 120kg f/cm² •Normal flow rate : 10ℓ/min •Cracking pressure : 1kg f/cm² •Coupling socket/Nipple (Built in Check Valve) •Inline Type •Quantity : 1 EA

IEG 4100-29 Line Check Valve-1 •Maximum operating pressure : 120kg f/cm²

IEG 4100-26 Bidirectional Flow Control Valve •Maximum operating pressure : 120kg f/cm² •Normal flow rate : 10ℓ/min •Inline type •Coupling socket/Nipple (Built in Check Valve)

•Cracking pressure : 1.0kg f/cm² •Inline type •Coupling socket/Nipple (Built in Check Valve) •Quantity : 1 EA

•Quantity : 1 EA

IEG 4100-27 Pressure compensation Flow Control Valve •Maximum operating pressure : 120kg f/cm² •Inline type •Coupling socket/Nipple (Built in Check Valve) •Quantity : 1 EA

www.ptakasa.com

147 IEG 4100-30 Line Check Valve-2

IEG 4100-38 Hydraulic Motor

•Maximum operating pressure : 120kg f/cm²

•Operating pressure : 120 kg f/cm²

•Cracking pressure : 5.0kg f/cm²

•Structure : Internal gear

•Inline type

•CW, CCW direction working

•Coupling socket/Nipple (Built in Check Valve)

•Maximum RPM : 1950 RPM

•Quantity : 1 EA

•Quantity : 1 EA

IEG 4100-31 T-Connector •Maximum operating pressure : 120kg f/cm² •Purpose of use : circuit wiring (Divergence) •Inline type •Coupling socket (Built in Check Valve) •Quantity : 1 EA

IEG 4100-45 Throttle Tranparancy Block •Maximum operating pressure : 60kg f/cm² •Throttle diameter : 2mm •Throttle length : 30mm •Identifiable by the transparent block •Hand lever : one-touch method •Quantity : 1 EA

IEG 4100-33 Pressure Gauge •Maximum operating pressure : 0 ~ 100kg f/cm² •Nominal diameter : 60mm •Viscosity : 1.6%

IEG 4100-46 Orifice Tranparancy Block

•Buffering oil : Glycerin

•Maximum operating pressure : 60kg f/cm²

•Inline type

•Length of Orifice : 0.5mm

•Coupling socket/Nipple (Built in Check Valve)

•Identifiable by transparent block

•Quantity : 1 EA

•Hand lever : one-touch method •Quantity : 1EA

www.ptakasa.com

148 IEG 4100-47 Accumulator

IEG 4100-50 Flow Resistence Hose (Type B)

•Nitrogen pressure : 10kg f/cm²

•Maximum operating pressure : 0~30 kgf/㎠

•Gas in use : nitrogen

•Length of hose : 6Ф 1300mm (Approx.)

•Accumulator volume : 0.7ℓ

•Cylindrical type

•Type of operation : hydraulic

•Quantity : 1EA

•Control method : manual •Relief valve as mounted •Quantity : 1 EA

IEG 4100-48 Load

IEG 4100-51 Flow Resistence Hose (C type)

•Weight : 10Kg

•Maximum operating pressure : 0~30 kgf/㎠

•Diameter : 100mm

•Length of hose : 4Ф 2500mm (Approx.)

•Length : 160mm

•Cylindrical type

•Quantity : 1 EA

•Quantity : 1EA

IEG 4100-49 Flow Resistence Hose (Type A)

IEG 4100-55 Pressure Filter

•Maximum operating pressure : 0~30kg f/cm²

•Maximum operating pressure : 120kg f/cm²

•Length of hose : 4Ф 1300mm (Approx.)

•Control flow : 0.01-4ℓ/min

•Cylindrical type

•Type of operation : mechanical

•Quantity : 1EA

(forward/backward roller) •Tempreature compensation type valve •Quantity : 1 EA

www.ptakasa.com

149 IEG 4100-57 Accumulator charging devices

IEG 4100-59 3/2-Way Solenoid Valve

•Accumulator charging : nitrogen

•Maximum operating pressure: 120 kgf/㎠

•Hydraulic Valve and hose

•Working voltage : DC24V / 6.5W

•Quantity : 1 EA

•Coil current : 1.17A •Built in LED protection circuit •Type of return : spring return/Normal closed •Valve nominal size : NG4 •Hand lever : one-touch method •Quantity : 1EA

IEG 4100-64 Pressure Switch •Operating pressure : 10-160kg f/cm² •Contact composition : 1a, 1b, load capability 3A

IEG 4100-60 4/2-way Single Acting Solenoid Valve •Maximum operating pressure : 120kg f/cm²

•Controllable of pressure sensor

•Working voltage : DC24V / 6.5W

•Quantity : 1 EA

•Built in LED protection circuit •Type of return : spring return •Valve nominal size : NG4 •Hand lever : one-touch method

IEG 4100-58 2/2-Way Solenoid Valve •Maximum operating pressure : 120kg f/cm² •Working voltage : DC24V / 6.5W •Built in LED protection circuit •Type of return : spring return/Normal closed •Valve nominal size : NG4 •Hand lever : one-touch method •Quantity : 1EA

•Quantity : 1EA

IEG 4100-61 4/2-way Double Acting Solenoid Valve •Maximum operating pressure : 120kg f/cm² •Working voltage : DC24V / 6.5W •Built in LED protection circuit •Detant (Locking) function •Valve nominal size : NG4 •Hand lever : one-touch method •Quantity : 1EA

www.ptakasa.com

150 IEG 4100-62 4/3-way Double Acting Solenoid Valve (All Block)

IEG4100-66 4/3-way Double Acting Solenoid Valve (All Open)

•Maximum operating pressure : 120kg f/cm²

•Maximum operating pressure: 120 kgf/㎠

•Working voltage : DC24V / 6.5W

•Working voltage : DC24V / 6.5W

•Built in LED protection circuit

•PABT Junction (all open)

•PABT cut off type (all block)

•Valve nominal size : NG4

•Valve nominal size : NG4

•Hand lever : one-touch method

•Hand lever : one-touch method

•Quantity : 1EA

•Quantity : 1EA

IEG4100-67 4/3-way Double Acting Solenoid Valve (PAB)

IEG 4100-63 4/3-way Double Acting Solenoid Valve (By-Pass) •Maximum operating pressure: 120 kgf/㎠ •Working voltage : DC24V / 6.5W •Built in LED protection circuit •PT Junction (by pass) •Valve nominal size : NG4 •Including connector after completing inside of sub-base •Hand lever : one-touch method •Quantity : 1EA

•Maximum operating pressure : 120 kgf/㎠ •Working voltage : DC24V / 6.5W •Built in LED protection circuit •PAB Junction •Valve nominal size : NG4 •Hand lever : one-touch method •Quantity : 1EA

IEG 4000-49 Photo Sensor •Sensing distance : Maximum 100mm •Power : DC 12 ~ 25V ±10%

IEG4100-65 4/3-way Double Acting Solenoid Valve (ABT) •Maximum operating pressure: 120 kgf/㎠ •Working voltage : DC24V / 6.5W •Coil current : 1.17A •Built in LED protection circuit/ ABT Junction •Valve nominal size : NG4 •Hand lever : one-touch method •Quantity : 1EA

•Current consumption : Less than 40mA •Output : NPN Open Collector •Response time : Less than 3ms •Rated output : current 100mA / voltage (less than 30V) •Possible to change (attach/detach) it vertically and horizontally at profile using lever and cam •Quantity : 1EA

www.ptakasa.com

151 IEG 4000-50 Capacitive Sensor

IEG 4000-53 Limit Switch (L)

•Sensing distance : 8mm

•Roller lever operational type

•Power : DC 10~30V

•Contact composition : 1c

•Current consumption : Less than 15 mA

•Contact rating : DC 24V 5A

•Load current : Less than 200 mA

•Possible to change (attach/detach) it vertically

•Output : NPN Open Collector

and horizontally at profile using lever and cam

•Response time : Less than 3ms

•Quantity : 1 EA

•Possible to change (attach/detach) it vertically and horizontally at profile using lever and cam

IEG 4000-54 Limit Switch (R)

•Quantity : 1EA

•Roller lever operational type •Contact composition : 1c

IEG 4000-51 High-frequency oscillator-typed proximity Sensor (NPN)

•Contact rating : DC 24V 5A

•Sensing distance : 8mm

•Possible to change (attach/detach) it vertically

•Power : DC 10~30V

and horizontally at profile using lever and cam

•Current consumption : 10 mA

•Quantity : 1EA

•Load current : Less than 200 mA (R Load) •Possible to change (attach/detach) it vertically

IEG 4000-55 Power Supply

and horizontally at profile using lever and cam

•Input voltage : AC 220V/50~60Hz

•Quantity : 1EA

•Output : more than 24V 8A •Built in over current protection circuit •Buzzer sounds at the occurrence of overload

IEG 4000-52 High-frequency oscillator-typed proximity Sensor (PNP)

•Possible to change (attach/detach) it vertically

•Sensing distance : 8mm

and horizontally at profile using lever

•Power : DC 10~30V

and cam

•Current consumption : 10 mA

•Quantity : 1EA

•Load current : Less than 200 mA (R Load) •Response frequency : 100Hz •Diameter of detected side : 30mm •Possible to change (attach/detach) it vertically and horizontally at profile using lever and cam •Quantity : 1EA

www.ptakasa.com

152 IEG 4000-41 3 Fold Relay Unit

IEG 4000-43 Digital Counter Unit

•Relay : 3EA

•Contact composition : 1a,1b

•Contact composition : 4c/ 1EA

•Input voltage : DC 24V, Built in protection circuit

•Contact rating : DC 24V 3A

•Output contact : AC250V 3A (when resistance is on load)

•Input voltage : DC 24V

•Electro signal, manually reset

•Auxiliary power terminal : +Terminal(6EA), -Terminal(6EA)

•Counter function : adding, deducting

•Injection cases that are able to extend side frame on insulation

•Counting signal : signal for contact/non-contact point

box

•Injection cases that are able to extend side frame on insulation box

•Possible to change(attach/detach) it vertically

•Possible to change(attach/detach) it vertically

and horizontally at profile using lever and cam

and horizontally at profile using lever and cam

•Quantity : 1EA

•Quantity : 1EA

IEG 4000-42 Digital Time Relay Unit

IEG 4000-44 Electro Signal Switch Unit A

•Timer : 2EA

•Return type switch: 2 EA (equipped)

•Contact composition : 2a,2b/ 1EA

•Lock type switch: 1 EA (equipped)

•Input voltage : DC 24V

•DC 24V Lamp (Red, Green, Yellow)

•Delay Timer : 0.5~10sec

•Contact composition: 2a, 2b, 2c/ 1EA

•Type of operation : Time ON Delay

•Rated current: DC 24V 1.5A

•Auxiliary power terminal : +Terminal(6EA), -Terminal(6EA)

•Injection cases that are able to extend side frame on insulation box

•Injection cases that are able to extend side frame on

•Possible to change(attach/detach) it

insulation box

vertically

•Possible to change(attach/detach) it vertically

and horizontally at profile using lever and cam

and horizontally at profile using lever and cam

•Quantity : 1EA

•Quantity : 1EA

www.ptakasa.com

153 IEG 4000-45 Electro Signal Switch Unit B

IEG 4000-48 Buzzer & Lamp Unit

•Return type switch: 1 EA (equipped)

•DC 24V Buzzer: 1EA

•Lock type switch: 2 EA (equipped)

•DC 24V Lamp : 4EA (Red, Green, Yellow, White)

•DC 24V Lamp (Red, Green, Yellow)

•Injection cases that are able to extend side frame

•Contact composition: 2a, 2b, 2c/ 1EA

on insulation box

•Rated current: DC 24V 1.5A

•Possible to change(attach/detach) it vertically

•Injection cases that are able to extend side frame on

and horizontally at profile using lever and cam

insulation box

•Quantity : 1EA

•Possible to change(attach/detach) it vertically and

horizontally at profile using lever and cam

IEG 4000-56 Connection Cable Set

•Quantity : 1EA

•Red - 200mm : 5 EA / 500mm : 10 EA

IEG 4000-46 Emergency Switch Unit

- 1000mm : 10 EA / 1500mm : 10 EA

•Push button with lock function

•Black

•Contact composition : 1a � 1b

- 200mm : 5 EA / 500mm : 10 EA

•Rated current : DC 24V 5A

- 1000mm : 10 EA / 1500mm : 10 EA

•Built in insulation box

•Blue

•Quantity : 1EA

- 200mm : 10 EA / 500mm : 10 EA - 1000mm : 10 EA / 1500mm : 5 EA

IEG 4000-47A Electrical Distribution Unit

•Quantity : 1 SET

•+,- Contact : 2 circuits with each 6 ports on the top and the bottom •Contact for load : composed of 8 lines (Red/Green Lamp display) •Possible to install vertically and horizontally with tightening method •Quantity : 1EA

www.ptakasa.com

154

Ubiquitous System No. Name of Equipment 1. RFID Trainer Features:

Type IEG 5101

Quantity 1 Set

Please Contact

Price Picture

•900MHz RFID Reader supports Multi Protocol to satisfy both ISO, the international standard, and USA EPC Global Standard. •The multiple Tag Recognition is feasible and it is suitable to establishment of lagrescale logistics and distribution systems (widely used in such applied fields as assets, inventory, and product management.) •900MHz ISO18000-6C/EPC Global Gen2 Multi Protocol Support, 13.56MHz Supports ISO/IEC 14443 Type A,B and ISO/IEC 15693 Standards Protocol Support, 125KHz Protocols(Air Interface) ISO18000-2 Protocol Support •It is possible to practice the sensitivity measurement in accordance with the size of antenna by supplying the 13.56 MHz antenna of RFID Reader and adjust the antenna sensitivyit by using two trimmers of the antenna. •It is possible to control monitoring on PC's the RFID linkage to USB & RS232C by using Zigbee & PLC Modules. •It is possible to control home devices by using TCP/IP (Network) and upgrade the Firmware based on USB. •Practice the tag information and applications based on ATmega 89C51 and ATmega128 processors. •Provide Embedded (PXA270)-based RFID home-network system DC fAN, LED lamp, heating valve, outlet AC 220V, relay, ext port-linked control and relevant application S/W. •Provide 900MHz,13.56MHz, and 125kHz RFID application programs (based on Visual C++, LabVIEW, and QT(Linux) and the manual.

www.ptakasa.com

155 Specification (Antenna):  IEG 5101-1A Antenna 125KHz



IEG 5101-2A Antenna 13.56MHz

Specification (RFID Reader):  IEG 5101-1 RFID Reader (125KHz) • Main Component : Coil Antenna, ATmega128 JTAG Port, ISP Port USB 2.0 UART Test Port Array • Modulation : ASK (Amplitude Shift Keying) • 10cm Detection range (Dependent on Air-Interface protocols and Tag Brands) • Protocols (Air Interface) : ISO 18000-2 • Communication : RS232 Port, USB Port



IEG 5101-3A Antenna 900MHz



IEG 5101-3 RFID Reader (900MHz)

 IEG 5101-2 RFID Reader (13.56MHz) • Control Unit : CPU Core Module : AT89C51, Atmega128 • Multi-protocol RFID Reader : TRH0M31 • Protocol : ISO/IEC 14443 A/B, 15693 Standards • Modulation Type : ASK 8 ~ 100% • Operating Range : ISO 14443 A/B
View more...