iCIM Manual A002

July 16, 2017 | Author: Abraham Torres | Category: Ac Power Plugs And Sockets, Numerical Control, Safety, Modularity, Automation
Share Embed Donate


Short Description

Download iCIM Manual A002...

Description

iCIM Manual

Order-NR.: Type:

Manual iCIM

Designation

iCIM_Manual_A002

Printed:

01.08.2003

Autor:

Schober

Graphics:

Schober

Layout:

Schober

© Festo Didactic GmbH & Co.KG, D-73770 Denkendorf, 2003 Internet: www.festo.com/didactic e-mail: [email protected] This manual, all text and illustrations contained included, is protected by copyright. Any utilisation outside the limits of the copyright law and other than training purposes are not permissible without our definite approval. This applies in particular to reproductions, operations, translations, micro filming and the storing and processing into electronic systems. Parts of this manual may be copied by the authorised user, exclusively for teaching purposes. Distribution of this documentation, as well as reproduction, use and spread of its contents is prohibited, insofar not permitted explicitly. Offences are liable to compensation. All rights reserved, especially the right to execute registrations concerning patents, designs for use and patterns.

2

© Festo Didactic GmbH & Co.KG. • FMS 100

1. Intended use

The User Manual must be to hand at all times. Keep it close to the machine.

This installation was developed and manufactured only for use in basic and further training in the fields of automation and communications. The training company and/or the training staff must ensure that the trainees observe the safety precautions described in the accompanying manuals. Furthermore this manual describes setup and possible uses of the singular stations. It contains all information and data required for commissioning, maintenance and operation. Festo Didactic accepts no liability for injury or harm to trainees, the training company and/or any third parties occurring when the installation is used for any purpose apart from training, except Festo Didactic has caused such injury or harm intentionally or by grossly negligence.

The manual is divided into different parts: • Part A In addition to technical data, Part A contains an overview of the possible uses of the station/System. • Part B Part B contains information’s witch are not assigned to the stations manual.

© Festo Didactic GmbH & Co.KG. • FMS100

3

List of applicable standards and regulations

The list below provides an overview of the most important standards and regulations relating to mechanical, electrical and safety-engineering design and production.

• • • • • • • • • •

DIN EN 292 -Machine safety DIN EN 60204 - Electrical equipment of industrial machines DIN VDE 0113 - See DIN EN 60204 DIN 40719 - Circuit documentation VDI 2853 - Technical safety requirements concerning the building, equipping and operation of industrial robots VDI 2853 - Technical safety requirements concerning automated production systems VDI 2411 - Terms and explanations in conveying and handling VDI 2860 - Assembly and robotics - terms VDI 2861 - Assembly and robotics - characteristic quantities DIN 19245 - PROFIBUS Part 1-3

As far as possible, the System is maintenance-free. All bearings are lubricated for life. The installation was designed in such a way as to keep the number of wearing parts to a minimum. This does not include machines that are part of optional expansions (such as industrial robots).

At this point we would like to point out that this manual and the concept of the operating instructions for a Flexible Training System of this type are regularly updated. To ensure that the instructions are ever more user-friendly, you would help us a great deal by passing on your suggestions for improvement. Please let us know of your suggestions, corrections or ideas, either in writing or via telephone: +49(711-3467-0)

4

© Festo Didactic GmbH & Co.KG. • FMS 100

2. Contents

1.

Intended use ___________________________________________________ 3

2.

Contents_______________________________________________________ 5

3.

Introduction ___________________________________________________ 11 3.1.

General_____________________________________________________ 11

3.2.

Resources __________________________________________________ 17

3.3.

Didactic structure ____________________________________________ 19

3.4.

Scope of tasks of the stations __________________________________ 20

3.4.1.

Mechanics ______________________________________________ 20

3.4.2.

Pneumatics _____________________________________________ 20

3.4.3.

Electrics ________________________________________________ 20

3.4.4.

Informatics______________________________________________ 20

3.4.5.

Bus technology __________________________________________ 20

4.

General safety instructions _______________________________________ 21 4.1.

Use according to regulations ___________________________________ 21

4.2.

Handling the system __________________________________________ 21

4.2.1.

Dangers in handling the machine ____________________________ 21

4.2.2.

Safety precautions in standard operation _____________________ 21

4.2.3.

Dangers due to electric current _____________________________ 22

4.2.4.

Dangers due to pneumatic energy ___________________________ 22

4.2.5.

Maintenance – Servicing – Malfunction removal ________________ 23

4.2.6.

Organizational measures __________________________________ 23

4.3.

© Festo Didactic GmbH & Co.KG. • FMS 100

Personnel___________________________________________________ 23

5

Contents

4.3.1.

Notes on personnel _______________________________________ 23

4.3.2.

Training operations _______________________________________ 23

4.3.3.

Outside training operations ________________________________ 23

4.3.4.

Safety symbols __________________________________________ 24

5.

Commissioning ________________________________________________ 25 5.1.

Transport ___________________________________________________ 25

5.2.

Set up______________________________________________________ 26

5.2.1. 5.3.

Commissioning ______________________________________________ 29

5.3.1.

Pneumatical commissioning ________________________________ 31

5.3.2.

Electrical commissioning __________________________________ 31

5.3.3.

Communication cables ____________________________________ 32

5.4.

6

General information ______________________________________ 26

Start up the system ___________________________________________ 34

5.4.1.

First time list ____________________________________________ 34

5.4.2.

Start up conditions _______________________________________ 36

5.4.3.

general information_______________________________________ 36

5.4.4.

Adjust AS/RS station______________________________________ 37

5.4.5.

CNC-coupling station______________________________________ 37

5.4.6.

Robot-Vision assembly station ______________________________ 38

5.4.7.

Adjust transport system ___________________________________ 38

5.4.8.

Start up cell control (COSIMIR CONTROL) _____________________ 39

5.4.9.

Start-up of processes _____________________________________ 39

© Festo Didactic GmbH & Co.KG. • FMS 100

Contents

5.5. 6.

Shut down the system_________________________________________ 39 Operation_____________________________________________________ 41

6.1.

General operation notes _______________________________________ 41

6.1.1.

Behavior rules ___________________________________________ 41

6.1.2.

Operation rules __________________________________________ 41

6.2.

Process description___________________________________________ 42

6.2.1. 6.3.

Process overview_____________________________________________ 44

6.3.1.

Sub-process 500 _________________________________________ 45

6.3.2.

Sub-process 501 _________________________________________ 46

6.3.3.

Sub-process 502 _________________________________________ 47

6.3.4.

Sub-process 503 _________________________________________ 48

6.3.5.

Sub-process 506 _________________________________________ 49

6.3.6.

Sub-process 507 _________________________________________ 50

6.3.7.

Sub-process 510 _________________________________________ 51

6.4.

Start up Cosimir Control _______________________________________ 52

6.4.1.

Choose project___________________________________________ 52

6.4.2.

Check adjustments _______________________________________ 54

6.4.3.

Change to production _____________________________________ 58

6.5.

COSIMIR CONTROL operation___________________________________ 59

6.5.1. 6.6.

© Festo Didactic GmbH & Co.KG. • FMS100

General information ______________________________________ 42

Start-up of processes _____________________________________ 59

COSIMIR CONTROL further information ___________________________ 66

7

Contents

6.6.1.

Further information about the stations _______________________ 66

6.6.2.

Further information about the zoom _________________________ 69

6.6.3.

Shut down COSIMIR CONTROL ______________________________ 70

6.7.

COSIMIR CONTROL AS/RS Manager______________________________ 72

6.7.1.

Modify function __________________________________________ 74

6.7.2.

Retrieve function / Search for part number ____________________ 77

6.7.3.

Retrieve function / retrieve shelf direct _______________________ 79

6.7.4.

Zoning _________________________________________________ 81

6.7.5.

Store function / search for empty shelf _______________________ 82

6.7.6.

Store function / store shelf direct ___________________________ 84

6.7.7.

Move part_______________________________________________ 86

6.7.8.

First time init ____________________________________________ 88

6.7.9.

Edit Product list __________________________________________ 90

6.7.10.

Trouble shooting / AS-RS-Manager ________________________ 93

6.7.11.

RETRIEVE mode / RETRIEVE SHELF DIRECT __________________ 94

6.8.

Order codes Transport system stoppers PLC – COSIMIR CONTROL _____ 96

6.9.

Order codes Transport system hubix PLC – COSIMIR CONTROL ________ 97

6.10.

Order codes AS/RS 40 PLC – COSIMIR CONTROL _________________ 98

6.11.

Order codes CNC-coupling station Drive Unit – COSIMIR CONTROL___ 99

6.12. Order codes Robot-vision assembly station Drive Unit – COSIMIR CONTROL ________________________________________________________ 102

8

6.13.

Cell control_______________________________________________ 106

6.14.

Partnumbers _____________________________________________ 107

© Festo Didactic GmbH & Co.KG. • FMS 100

Contents

6.15. 7.

Workpiece direction _______________________________________ 109

Pneumatic ___________________________________________________ 111 7.1.

The valve terminal ___________________________________________ 111

7.2.

Pneumatic supply ___________________________________________ 112

8.

Electrical system ______________________________________________ 113 8.1.

Power supply _______________________________________________ 113

8.2.

Controller example __________________________________________ 114

8.2.1. 8.3.

© Festo Didactic GmbH & Co.KG. • FMS100

Controller design S7 _____________________________________ 114

Electrical components________________________________________ 115

8.3.1.

I/O-Components ________________________________________ 115

8.3.2.

ASI ___________________________________________________ 117

9

Contents

10

© Festo Didactic GmbH & Co.KG. • FMS 100

3. Introduction

3.1. General

This user-defined installation contains parts of the iCIM system, mixed together with other components. The installation, thus created, is explained in the following operational manual and the respective station manuals. In the development of the system, various production technologies have been combined into one installation. The aim of the installation is the increase of competence, from a simple setting of examples up to a complete production process, including all features. Additionally, to technical and social competence, the comprehension of the process and the interaction of the respective components appear in clear presentation. This manual describes working with the iCIM system. Everything is explained and described for the operation of necessary events. With the help of graphics or pictures a simple communication should be obtain. Complete operating instructions which explain the processes of the system are available for working with the system. Station manuals are also available for the individual stations. Additionally to technical and social competence, the comprehension of the process and the interaction of the respective components appear in clear presentation. Festo Didactic succeeded in using the most updated industrial hard- and software for this model production.

© Festo Didactic GmbH & Co.KG. • FMS 100

11

Introduction

The training equipment of the iCIM system consists of various stations, which can be configured individually, into single stations, or into a complete processing system in connection with other stations. This user manual applies to operations in a complete process. In case the stations are used in the “stand alone” mode, the respective programs have to be created by the user themselves. At the time, there is just one operation integrated for stand alone mode.

The iCIM System consists of the following stations

Transport system

In the whole system, the transport system is responsible for the transport of the work-pieces, which are placed upon special work-piece carriers. The controller for the transport system is a Siemens S7 313C 2DP

12

© Festo Didactic GmbH & Co.KG. • FMS 100

Introduction

AS-RS station

The AS/RS station has the function to provide and store the work-pieces and various palettes. There are 40 shelf’s available. The station is mounted at operating position 1. The controller is a Siemens S7-313C.

© Festo Didactic GmbH & Co.KG. • FMS100

13

Introduction

Robot assembly station

The robot assembly station has the function to collect the basic plate from the station before and to assemble it completely. Once the deskset has been assembled it is moved onto the following station. The station is standing at operation position 3. The controller is a Mitsubishi CR1 Drive Unit.

14

© Festo Didactic GmbH & Co.KG. • FMS 100

Introduction

CNC-coupling station

The CNC-coupling station is responsible for the production of the workpieces. Two CNC milling machines are available for the production. The transport paths and equipment of the machine is taken over by a RV-2A robot, which is mounted onto a linear axis. The station is standing at operation position 5. The controller is a Mitsubishi CR1 Drive Unit.

© Festo Didactic GmbH & Co.KG. • FMS100

15

Introduction

Cell control PC For operational executions a cell control is available, containing Lucas software, for operations of the processes. • • • • • •

16

Pentium min. 300 Mhz 128 MB main memory 20 GB hard disk Software: Windows NT and COSIMIR CONTROL ITEC-Profibus card EzDDE drive Min. 19” monitor

© Festo Didactic GmbH & Co.KG. • FMS 100

Introduction

3.2. Resources

The training equipment of the iCIM system consists of various resources. The varied resources are being used, according to the choice of operation. For the iCIM system following resources are available:

workpiece carrier

8 work-piece carriers are available for the transport of the work-piece pallets.

Pallet 1BP

20 pallets are also available for the reception of 1 base plate. The partnumber is 62201.

© Festo Didactic GmbH & Co.KG. • FMS100

17

Introduction

Palette 1PH

20 pallets are also available for the reception of 1 pen holder, processed or not. Partnumber 62200.

Work piece sets examples

Variant

Description

1

Desk set with 2 magnet, pen holder brass, without pen

2

Desk set with 2 magnet, pen holder aluminum, with pen

3

Desk set with 2 instruments, pen holder aluminum, with pen

4

Desk set with 1 magnet, 1 instrument, pen holder brass, with pen.

To fill all of the magazines for the production of various desk set, one work-piece set is enclosed with component parts for 10 desk set.

18

© Festo Didactic GmbH & Co.KG. • FMS 100

Introduction

3.3. Didactic structure

The installation is structured, to enable methodical learning, i.e. from single use of modules to the complex and complete installation. Perhaps even in combination with further systems. For example, it is possible to pick out a single module to start with the first steps, e.g. the robot. • First the mechanical assembly is considered. The robot’s radius of action requires integration into the location of the robot. • The following step could be the connection of all cables required for operation and the set-up of the robot. • Moving the robot and teaching the required positions are the first real operations with the robot, which introduces the user how to deal with the teach-box. • The robot’s programming can be started, as soon as the robot can be moved by the teach-box. Small programs, which can be created by using the Cosimir/Cosirob software, are expandable for the complex programs. • Orders to further stations and from other controls can be installed in the programs.

Once the learning process of this module has been concluded, these learning steps can be transferred to the next module. As soon as all of the modules have been processed individually, the modules can be interconnected and the programs can be adapted. A complete production process can be simulated. This is an ideal training area for the professional practice of mechatronis, as well as all of the technical ranges (mechanical, electrical and pneumatic processes) are represented in a simple and clearly way, concerning each one of the modules and the complete system.

© Festo Didactic GmbH & Co.KG. • FMS100

19

Introduction

3.4. Scope of tasks of the stations

The stations are possessing a varied range of functions. A small extraction of the various possibilities of the stations follows. 3.4.1.

Mechanics

• Obtaining basic mechanical skills about the assembly of basic modules • Obtaining complex mechanical skills about the assembly of a complete station or complex modules • Assembly provides instructions about the technical connections between the various components

3.4.2.

Pneumatics

• Understanding of a pneumatic circuit by set-up and pipe connection of the cylinders and valves

3.4.3.

Electrics

• Obtaining electrical knowledge of reading a circuit diagram, concerning the wiring of sensors and valves • Functional understanding of the individual modules e.g. in case of error detection, by means of a circuit diagram and a measuring device

3.4.4.

Informatics

• Understanding of programs receiving an insight by controlling the individual components of the programs • Changing and improving programs recognising and removing errors in a complete program • Writing new programs new programs can be written by combination of the skills obtained in the steps before.

3.4.5.

Bus technology

• Instructions in the various bus technologies avoidance to gain intimate knowledge about the various bus technologies is made impossible by working with the programs

20

© Festo Didactic GmbH & Co.KG. • FMS 100

4. General safety instructions

4.1. Use according to regulations

This installation has been developed and produced exclusively for training purposes in the fields of automation and communication. The training company, as well as the instructors have to ensure, that the trainees pay strict attention to the safety precautions, as described in the accompanying manuals. Festo Didactic accepts no liability charges for possible damages to any trainee of the training company and/or further third parties, which might occur during use/operation of the installation, if it is not part of a real training situation; except Festo Didactic caused such damages deliberately or by negligence. Due to the product liability law and various EC-directives, the following directions are required and are to be strictly observed by the operator.

4.2. Handling the system

4.2.1.

Dangers in handling the machine

The installation has been constructed technologically up to date and in conformance with the recognized rules of safety engineering. Nevertheless, during operation it is possible that harm might be caused to the user or third parties or that the installation or other property might get damaged. Therefore, the installation has to be handled according to specified operational use in perfect technical condition only. Safety endangering malfunctions can not be tolerated during training and have to be removed immediately.

4.2.2.

Safety precautions in standard operation

Put the installation into operation only, once all of the protection settings are completely functional. At least, before starting operation, check the installation for externally visible damages and for the reliability of the safety devices. Do not grip into the installation while in operation. Before circuit construction, circuit disassembly and circuit modification: switch off air pressure and power supply. General safety regulations are to be observed: DIN 58126 and VDE 0100.

© Festo Didactic GmbH & Co.KG. • FMS 100

21

General safety instructions

4.2.3.

Dangers due to electric current

As soon as maintenance is completed, check the function reliability of the safety devices. Only trained experts in electric or electronic engineering are permitted to carry out work on the electric supply system. The terminal boxes are to be kept closed at all times. Access must be permitted only under supervision of a member of the training staff. Do not activate electric limit switches manually during fault search. Tools are to be used. Only low voltage 24VDC is to be used. 4.2.4.

Dangers due to pneumatic energy

Accidents might occur due to bouncing off tubes, caused by air pressure. Interrupt air pressure supply immediately. Caution! When the air pressure supply is activated, cylinders may move in or out. Do not uncouple any tubes under air pressure supply. Exception: Fault finding. In this case, keep on holding the end of the tube. Do not exceed the permitted operating pressure. See data sheets.

22

© Festo Didactic GmbH & Co.KG. • FMS 100

General safety instructions

4.2.5.

Maintenance – Servicing – Malfunction removal

Carry out adjustments and inspections as instructed, in accordance with the specified intervals. Secure the compressed air and electricity supplies to prevent unintentional start-up. During inspections, maintenance and repair work, the machine must be deenergized, de-pressurized and secured against unexpected restart. All screw connections released during maintenance, inspection or repair work must be checked to ensure correct re-tightening. 4.2.6.

Organizational measures

All existing safety devices must be checked at regular intervals. 4.3. Personnel

4.3.1.

Notes on personnel

Basically two situations have to be considered, concerning matters on personnel. • Activities during training operations • Activities outside training operations

4.3.2.

Training operations

Trainees are permitted to work with the machine only under strict supervision of an experienced person or an instructor. Activities of trouble-shooting and fault correction are to be checked by the instructor. Special care should be taken regarding safety aspects. 4.3.3.

Outside training operations

Activities in the areas of maintenance, service and repair are to be carried out by only persons with appropriate technical qualifications.

© Festo Didactic GmbH & Co.KG. • FMS100

23

General safety instructions

4.3.4.

Safety symbols

In this manual the following danger designations and signs are being used:

This symbol indicates an immediate threat to a persons health or life. DANGER ! Failure to pay attention to this symbol may result in serious health damage, which may even lead to life-threatening injuries.

This symbol emphasizes important information for correct machine handling. IMPORTANT Failure to pay attention to this symbol may result in damages to the machine or to its surroundings.

This symbol indicates operational tips and especially useful directions.

i

INFORMATION This symbol assists you to make optimal use of all of your machine’s functions.

24

© Festo Didactic GmbH & Co.KG. • FMS 100

5. Commissioning

5.1. Transport

i

Care is to be taken that the transport of the stations is to be executed only by a suitable transport vehicle. The weight amounts up to 500 kg, depending on the station. The route of transport is to be cleared in advance, to be accessible to the transport vehicle. Installation of warning signs or barriers may be required. The transport boxes are to be opened with care, as additional components, such as computers may be contained in the delivery, which are to be protected from falling out. Once the transport box has been opened and the possibly contained additional components removed, the station can be taken out to be transported to its destination by means of two fork-lifts or one fork-lift truck. Please check the stability of all of the profile connectors by means of an Allen key size 6. The connectors may have come loose during transport, due to inevitable vibration. Pay special attention to all overhanging components. Sensors and similar small parts are very easily damaged in case of improper transport. The stations are not to be picked up by or even under the mounted feet – increased risk of becoming trapped or contused.

© Festo Didactic GmbH & Co.KG. • FMS 100

25

Commissioning

5.2. Set up

5.2.1.

General information

The installation is to be set up in a frost-free room with maximum relative air humidity of 70%. In countries with an atmospheric humidity over 70% and temperatures above 25 degrees Celsius are the premises to provide an air-conditioning system for constant surroundings conditions. To comply with the regulatory guidelines, sources of electrical interference such as welding plants, large motors and contactors are to be checked for electromagnetic compatibility in advance and screened where necessary. To ensure fault-free operation a load-bearing floor is required to avoid settling. Allow sufficient distance between the installation and the wall of the room. Any dust originating from construction work has to be kept off the installation (by covering).

26

© Festo Didactic GmbH & Co.KG. • FMS 100

Commissioning

For a more simple room planning the complete installation design is shown in the following.

Installation design iCIM system

Operating position 1

In operating position 1 the AS/RS is fixed to the transport system

Operating position 2

Operating position 2 is not occupied.

Operating position 3

In operating position 4 the robot assembly station is fixed to the transport system.

Operating position 4

Operating position 4 is not occupied.

Operating position 5

The CNC-coupling station is connected in operating position 5.

Operating position 6

Operating position 6 is not occupied.

© Festo Didactic GmbH & Co.KG. • FMS100

27

Commissioning

Dimension drawing iCIM system

28

© Festo Didactic GmbH & Co.KG. • FMS 100

Commissioning

5.3. Commissioning

For the set-up of the system please follow the instructions below: First, the room has to be measured, if not done so previously. The measures of all stations have to be marked roughly onto the floor space (i.e. with adhesive tape) to avoid shifting at a later stage. The positions and the detailed information for commissioning can be found in each of the station manuals. Please keep to the sequential order as listed below!

Set-up of the transport system

At first, the transport system has to be set up. The station is placed in its final position, before it is balanced, by means of a spirit-level. The conveyor belt should be at a height of 896mm, according to the height of the conveyor belt. All of the segments of the conveyor belt require to be screwed together tightly. An exact installation illustration is available from the station’s manual.

Set-up of the AS/RS station

The AS/RS station has to be mounted on operating position 1 of the transport system, utilizing the included profiles. Afterwards, the distance of the AS/RS station is fixed in such a way, that the telescopic transfer unit is able to move in extended status over operating position 1. At this point, screw and lean the profiles lightly onto the basic frame of the transport system station, by means of the angles. Align the AS/RS station by means of a spirit-level and tighten the connector profiles afterwards. It may be possible, that the transfer position of operating position 1must be taught corrected.

Set-up of the robot-vision assembly statoin

The robot vision assembly station is set up in its final position, at operating position 3. The installation is adjusted, by means of a spirit level, to a plate height of 785mm, by means of the adjustable feet. In case of very uneven ground, it may be necessary to underlay the adjustable feet. The station is connected to the transport system, by means of the assembly profile. The robot transfer position to the transport system and the positions for the work-piece transfer may require to be retaught.

© Festo Didactic GmbH & Co.KG. • FMS100

29

Commissioning

Set-up of the CNCCOUPLING station

The CNC-COUPLING station is set up in its final position, at operating position 5 The installation is adjusted, by means of a spirit level, to a plate height of 785mm, by means of the adjustable feet. In case of very uneven ground, it may be necessary to underlay the adjustable feet. The station is connected to the transport system, by means of the assembly profiles, which are mounted underneath the linear axis. The CNC machines are to be set up in such a way, that the robot is able to place a workpiece into the vice of the respective machine. The robot transfer position to the transport system and the positions for the workpiece transfer may require to be retaught.

At this point, the installation is completely aligned. All of the mechanical operations should run without problems. In some cases, the transfer positions of the workpieces or palettes require to be taught anew, as explained in detail in the respective chapters of the station’s manual.

30

© Festo Didactic GmbH & Co.KG. • FMS 100

Commissioning

5.3.1.

Pneumatical commissioning

The mechanical construction must be finished. At the beginning the stations have to be attached to the pneumatic system of the room. In most cases the maintenance unit is on the profile plate of the station. The coupling has a 5 mm nominal diameter. If the available system is equipped with 7.9 mm nominal diameter, it is possible to change the coupling of the maintenance unit with a greater one. (reducer 1/8 on 1/4 necessary). If this has been carried out, the stations can be provided with 6 bar and the pneumatic commissioning is realized. 5.3.2.

Electrical commissioning

The station must be provided with electrical voltage now. The control cabinets are provided with a voltage of 230 V. The delivered cable has a completely protected norm plug, this must be plugged into an electrical socket protected sufficiently. Distribution strips are, enclosed to this also for the connection of other stations. If an extension for the cable is necessary for the distribution strip, this can to be executed only by a trained expert. The electrical socket must be protected, corresponding to the customer. The power supply (24 VDC) of the sensoric and the actuators of the station is provided in each case by means of a 2-pin cable. The voltage supply is a 24 V power supply unit, contained in the control cabinet or somewhere in the station. Some of the stations are provided with a voltage of 380 V. The enclosed cable has a completely protected norm plug, this must be plugged into an electrical socket protected sufficiently. If an extension for the cable is necessary for the distribution strip, this can to be executed only by a trained expert. The electrical socket must be protected, corresponding to the customer. For more detailed information check the manual of the corresponding station.

© Festo Didactic GmbH & Co.KG. • FMS100

31

Commissioning

5.3.3.

Communication cables

The connections are different depending on the way of the stations. The main communication between all stations is done with Ethernet. The complete communication is shown in the illustration below.

Communication system

The data cable is plugged onto the Ethernet card of the control. A Ethernet distributor is required for transmission to the next stations.

32

© Festo Didactic GmbH & Co.KG. • FMS 100

Commissioning

The control layout is fixed, as shown in the previous illustration. The communication between the stations takes place in a standardized I/O-interface. The transport system is an exception; the communication in-between the station occurs right on the spot, by means of an ASi-bus. The communication in-between the stations and with the cell control occurs by Ethernet. Profibus DP is used as communication for the Ident system. Concerning their communication, the following addresses, have been allotted to the stations. Ethernet • • • • • •

AS/RS station Ethernet address # IP192.168.10.2 CNC-Coupling station Ethernet address # IP192.168.10.10 – Port 9002 Robot-Vision assembly station Ethernet address # IP192.168.10.12 – Port 9002 Camera on robot assembly station Ethernet address # IP192.168.10.120 Controller transport system Ethernet address # IP192.168.10.1 Cell control station Ethernet address # IP192.168.10.22

Profibus DP • Controller transport system address # 2 • Controller Pepperl & Fuchs address # 3 (Sensor 1-3) • Controller Pepperl & Fuchs address # 4 (Sensor 4-6)

© Festo Didactic GmbH & Co.KG. • FMS100

33

Commissioning

5.4. Start up the system

5.4.1.

First time list

This allocation of the AS/RS station fulfils the basic conditions to ensure the operation of the installation. This storage allocation is to be established with each production start-up.

34

Shelf

Part

number

number

Number

1

42000

Cylindrical raw material, Alu, d=30mm, l=80mm

8

2

42000

Cylindrical raw material, Alu, d=30mm, l=80mm

8

3

42000

Cylindrical raw material, Alu, d=30mm, l=80mm

8

4

42000

Cylindrical raw material, Alu, d=30mm, l=80mm

8

5

42000

Cylindrical raw material, Alu, d=30mm, l=80mm

8

6

42000

Cylindrical raw material, Alu, d=30mm, l=80mm

8

7

42000

Cylindrical raw material, Alu, d=30mm, l=80mm

8

8

42000

Cylindrical raw material, Alu, d=30mm, l=80mm

8

9

42001

Cylindrical raw material, Brass, d=30mm, l=80mm

8

10

42001

Cylindrical raw material, Brass, d=30mm, l=80mm

8

11

42001

Cylindrical raw material, Brass, d=30mm, l=80mm

8

12

42001

Cylindrical raw material, Brass, d=30mm, l=80mm

8

13

42001

Cylindrical raw material, Brass, d=30mm, l=80mm

8

14

42001

Cylindrical raw material, Brass, d=30mm, l=80mm

8

15

42001

Cylindrical raw material, Brass, d=30mm, l=80mm

8

16

42001

Cylindrical raw material, Brass, d=30mm, l=80mm

8

17

42010

Raw material, base plate, Alu, l=140mm, w=60mm

8

18

42010

Raw material, base plate, Alu, l=140mm, w=60mm

8

19

42010

Raw material, base plate, Alu, l=140mm, w=60mm

8

20

42010

Raw material, base plate, Alu, l=140mm, w=60mm

8

21

42010

Raw material, base plate, Alu, l=140mm, w=60mm

8

22

42010

Raw material, base plate, Alu, l=140mm, w=60mm

8

23

42010

Raw material, base plate, Alu, l=140mm, w=60mm

8

24

42010

Raw material, base plate, Alu, l=140mm, w=60mm

8

Designation

units

© Festo Didactic GmbH & Co.KG. • FMS 100

Commissioning

Shelf number

Part number

Designation

Number units

25

62200

Empty pallet for 1 cylindrical workpiece

8

26

62200

Empty pallet for 1 cylindrical workpiece

8

27

62200

Empty pallet for 1 cylindrical workpiece

8

28

62200

Empty pallet for 1 cylindrical workpiece

8

29

62200

Empty pallet for 1 cylindrical workpiece

8

30

62200

Empty pallet for 1 cylindrical workpiece

8

31

62200

Empty pallet for 1 cylindrical workpiece

8

32

62200

Empty pallet for 1 cylindrical workpiece

8

33

62201

Empty pallet for 1 base plate

8

34

62201

Empty pallet for 1 base plate

8

35

62201

Empty pallet for 1 base plate

8

36

62201

Empty pallet for 1 base plate

8

37

62201

Empty pallet for 1 base plate

8

38

62201

Empty pallet for 1 base plate

8

39

62201

Empty pallet for 1 base plate

8

40

62201

Empty pallet for 1 base plate

8

© Festo Didactic GmbH & Co.KG. • FMS100

35

Commissioning

5.4.2.

Start up conditions

For the iCIM system a first commissioning at Festo was already executed. The following explanation is for the commissioning at customer’s side. It is required, that all of the stations are set up, aligned and adjusted, before starting the system. All of the transfer and assembly positions have to be adjusted or taught. The first start-up and teaching of each station is explained in detail in the station’s manual and has to be executed before. 5.4.3. • • • • • • • • • • • •

36

general information

Switch on distribution strips Activate air supply for all stations min. 4 bar – max. 6 bar Activate master switch of the AS/RS station AUTO/MAN switch on AUTO Activate distribution strip of CNC-coupling station Do not activate the key switches of the CNC machines and the drive unit of the stations robot Activate distribution strip of robot-vision assembly station Do not activate the drive unit of the stations robot Unlock the emergency-off switch of all of the stations and confirm with the CONTROLLER ON button. Switch on the PC - COSIMIR CONTROL The switches of all teach-boxes of the robots are to be set to Disable. Activate the master switch of the CNC machines and the Drive units, once all of the controls have been started up. The key actuators of the CNC machine is to be set to FMS mode.

© Festo Didactic GmbH & Co.KG. • FMS 100

Commissioning

5.4.4.

Adjust AS/RS station

Danger of collision. In case the transfer handling is very close to or in imminent danger of collision with the transport system station, it is to be moved out of the danger area manually. The axis are to be moved very slowly only, otherwise voltage induction may occur. • If a palette is positioned in the transfer unit, it has to be removed. • The selector switch has to be in auto-mode • If the RESET lamp is flashing, start the adjustment operation by using the RESET button. • If the AUTOMATIC ON lamp is flashing, use the AUTOMATIC ON button to activate the station’s automatic mode.

5.4.5.

CNC-coupling station

Danger of collision. The linear axis of the CNC station moves to the stations table. Danger of collision. The arms of the robot have to be removed from any danger area of the CNC machines • Before starting the adjustment process, work-pieces and palletes remaining in the station or in the vice of the processing machines have to be removed. • Fill up all magazines • Start the adjustment process by using the RESET button. • Use the START button to activate the station’s automatic mode.

© Festo Didactic GmbH & Co.KG. • FMS100

37

Commissioning

5.4.6.

Robot-Vision assembly station

Danger of collision. The arms of the robot have to be removed from any danger area of the station. • Before starting the adjustment process, work-pieces and palletes remaining in the station have to be removed. • Fill up all magazines, pen magazines have to be filled up completely. • Start the adjustment process by using the RESET button. • Use the START button to activate the station’s automatic mode.

5.4.7.

Adjust transport system

• The transport system does not require a special adjustment mode. • All palettes have to be removed from the workpiece carriers • Use the AUTOMATIC ON button to activate the station’s automatic mode.

38

© Festo Didactic GmbH & Co.KG. • FMS 100

Commissioning

5.4.8.

Start up cell control (COSIMIR CONTROL)

• • • •

Start up cell control. Double click COSIMIR CONTROL icon Once the COSIMIR CONTROL picture display appears, a project can be chosen. Under “File” you can choose the project C:\ProgramFiles\COSIMIRCONTROL\Projects\Juarez\Juarez.lpj • Change to production (See chapter START UP COSIMIR CONTROL in this manual)

5.4.9.

Start-up of processes

At this point all of the stations are in automatic mode and fully operational. Existing or newly created processes can be started by means of the cell control. The creation of processes is described in detail in the station’s manual.

5.5. Shut down the system

To shut down the system its necessary to proceed as follows: • • • • • • • • • •

© Festo Didactic GmbH & Co.KG. • FMS100

Stop production of COSIMIR CONTROL Shut down COSIMIR CONTROL software Shut down windows and switch of PC. (press power button min. 3 sec.) Shut down the CNC-software at the CNC-machines with ALT + F4 Shut down windows Switch off main switch CNC-machines Switch off Mitsubishi Drive Units Press EMERGENCY button at all other stations Switch off all main switches Switch off all distribution stripes

39

Commissioning

40

© Festo Didactic GmbH & Co.KG. • FMS 100

6. Operation

This chapter describes the necessary control units for starting and stopping the system, as well as operating with the system. 6.1. General operation notes

The stations require some rules of operation witch should be observed. If they are not complied, faults in the processes are possible. Dangers for the physical health also cannot be excluded. It is recommended to observe the following rules strictly. 6.1.1. • • • •

Behavior rules

During the operation of the stations it is forbidden to grip in by hand. With larger audience a mechanical protection of the stations is necessary. Removing any cable under tension is forbidden. Water has to be kept away from the plant.

6.1.2.

Operation rules

• The stations only may be used by introduced persons. • The operation has to be carried out according to the operating instructions. • A pushing the different switches/push buttons of all control units uncheckedly has to be stopped. • No workpiece carriers may be taken by the system.

© Festo Didactic GmbH & Co.KG. • FMS 100

41

Operation

6.2. Process description

6.2.1.

General information

This description serves as a example for an complete process. To produce a deskset with two instruments, one penholder aluminum and one pen. The process plan is to split into 2 parallel process parts (P1 and P2). part P1:

Retrieve a processed penholder (aluminum, type 1) from stock and transport the pallet to scara station. Take the pallet from transport carrier to scara station.

part P2:

Retrieve a processed base plate from stock and transport the pallet to robot assembly station. Take the pallet from transport carrier to robot assembly station.

Merge:

Move base plate from pallet to assembly position. Assemble instrument 1 from magazine 1 to base plate. Assemble instrument 2 from magazine 2 to base plate. Assemble pen holder from pallet to base plate and assemble pen from pen magazine to penholder. Split process plan into 2 parallel process parts (P3 and P4)

part P3:

Request a empty carrier from transport system (REQUIRE). Move empty pallet from robot assembly station to transport carrier. Transport pallet to AS-RS to store empty pallet in AS-RS.

part P4:

Request a empty carrier from transport system (REQUIRE). Move pallet with complete deskset from robot assembly station to transport carrier. Transport pallet to AS-RS to store complete deskset in AS-RS

Merge:

end of process

42

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

Some of the stations and resources of the TRAINING FACTORY are product-neutral; others cannot be completely product-neutral, due to means of clamping devices or special grippers and palettes. Examples of product-neutral resources: • • • •

Transport system with carrier (without palettes) AS/RS station Robot (without special grip) CNC machines (without clamping jaws)

Examples of product-specified resources: • • • •

Robot assembly station with magazines Transport palettes with work-piece nests Robot grippers Clamping jaws for the CNC machines

The product-specified resources of the system are intended for the manufacture and assembly of a product family: Example of product family:

© Festo Didactic GmbH & Co.KG. • FMS100

43

Operation

6.3. Process overview

Process No.

500

44

Process description

Available

Produce a pen holder in 10 variant’s (only 1 variant is implemented at the moment). Raw material is coming from AS/RS

501

Produce a pen holder in 10 variant’s (only 1 variant is implemented at

502

Produce a base plate in 5 variant’s (only 1 variant is implemented at the

503

Produce a base plate in 5 variant’s (only 1 variant is implemented at the

506

Assemble a desk set 3 with 2 instruments, 1 pen holder made from

507

Assemble a desk set 5 with 2 instruments, 1 pen holder made from

510

Assemble a desk set 3 with 2 instruments, 1 pen holder made from aluminum with a pencil.

the moment). Raw material is coming from magazines on CNC-station

moment). Raw material is coming from AS/RS

moment). Raw material is coming from magazines on CNC-station

aluminum with a pencil.

brass with a pencil.

X

X

X

X

X

x

X

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

6.3.1.

Sub-process 500

To produce a penholder for a deskset, first is to retrieve a raw cylindrical workpiece from AS-RS (material, brass or aluminum, depends on user selection). Then transport the raw cylinder to CNC-coupling station. Move pallet from workpiece carrier onto CNC-coupling station. Load CNC-Turning machine with the raw cylindrical workpiece and select the respective CNC program. Start CNC program and process workpiece. Unload processed penholder from CNC machine back to pallet and request a empty carrier from transport system (REQUIRE). Move the pallet with the pen holder from CNC-coupling station to workpiece carrier. Transport the processed penholder back to AS-RS and store the penholder in AS-RS with the respective workpiece number. end of process To execute sub-process 500 the following equipment is required: • • • •

Transport system station CNC-coupling station AS/RS station Pallet Type 1PH

© Festo Didactic GmbH & Co.KG. • FMS100

45

Operation

6.3.2.

Sub-process 501

To produce a penholder for a deskset, first is to retrieve a empty pallet for one cylindrical workpiece from AS-RS and transport the pallet to CNC-coupling station. Move pallet from workpiece carrier onto CNC-coupling station and load CNC-turning machine with raw cylindrical workpiece from magazine 3 or 4. Magazine 3, if material brass is selected and magazine 4, if material aluminum is selected. Select CNC program, start CNC program and process workpiece. Unload processed penholder from CNC machine back to pallet and request a empty carrier from transport system (REQUIRE). Move the pallet with the pen holder from CNC-coupling station to workpiece carrier. Transport the processed penholder back to AS-RS and store the penholder in AS-RS with the respective workpiece number. end of process To execute sub-process 501 the following equipment is required: • • • •

46

Transport system station CNC-coupling station AS/RS station Pallet Type 1PH

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

6.3.3.

Sub-process 502

To produce a base plate for a deskset, first is to retrieve a raw base from AS-RS and transport the pallet with the base plate to CNC-coupling station. Move pallet from workpiece carrier onto CNC-coupling station and load CNC-milling machine with raw base plate. Select CNC program, start CNC program and process workpiece. Unload processed base plate from CNC machine back to pallet and request a empty carrier from transport system (REQUIRE). Move the pallet with the base plate from CNC-coupling station to workpiece carrier. Transport the processed base plate back to AS-RS and store the base plate in AS-RS with the respective workpiece number. end of process To execute sub-process 502 the following equipment is required: • • • •

Transport system station CNC-coupling station AS/RS station Pallet Type 1BP

© Festo Didactic GmbH & Co.KG. • FMS100

47

Operation

6.3.4.

Sub-process 503

To produce a base plate for a deskset, first is to retrieve a empty pallet from AS-RS and transport the pallet to CNC-coupling station. Move pallet from workpiece carrier onto CNC-coupling station. Load CNC-milling machine with raw base plate coming from magazine 5. Select CNC program, start CNC program and process workpiece. Unload processed base plate from CNC machine to empty pallet and request a empty carrier from transport system (REQUIRE). Move the pallet with the base plate from CNC-coupling station to workpiece carrier. Transport the processed base plate back to AS-RS and store the base plate in AS-RS with the respective workpiece number. end of process To execute sub-process 503 the following equipment is required: • • • •

48

Transport system station CNC-coupling station AS/RS station Pallet Type 1BP

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

6.3.5.

Sub-process 506

To produce a deskset with two instruments, one penholder aluminum and one pen. The process plan is to split into 2 parallel process parts (P1 and P2). part P1:

Retrieve a processed penholder (aluminum, type 1) from stock and transport the pallet to scara station. Take the pallet from transport carrier to scara station.

part P2:

Retrieve a processed base plate from stock and transport the pallet to robot assembly station. Take the pallet from transport carrier to robot assembly station.

Merge:

Move base plate from pallet to assembly position. Assemble instrument 1 from magazine 1 to base plate. Assemble instrument 2 from magazine 2 to base plate. Assemble pen holder from pallet to base plate and assemble pen from pen magazine to penholder. Split process plan into 2 parallel process parts (P3 and P4)

part P3:

Request a empty carrier from transport system (REQUIRE). Move empty pallet from robot assembly station to transport carrier. Transport pallet to AS-RS to store empty pallet in AS-RS.

part P4:

Request a empty carrier from transport system (REQUIRE). Move pallet with complete deskset from robot assembly station to transport carrier. Transport pallet to AS-RS to store complete deskset in AS-RS

Merge:

end of process

To execute sub-process 506 the following equipment is required:

• • • • •

Transport system station Robot assembly vision station AS/RS station Pallet Type 1PH Pallet Type 1BP

© Festo Didactic GmbH & Co.KG. • FMS100

49

Operation

6.3.6.

Sub-process 507

produce a deskset with two instruments, one penholder brass and one pen to process plan is to split into 2 parallel process parts (P1 and P2) part P1:

Retrieve a processed penholder (brass, type 1) from stock. Transport palette to Robot assembly vision station. Move palette from transport carrier to robot assembly vision station.

part P2:

Retrieve a processed base plate from stock. Transport palette to robot assembly vision station. Move pallet from transport carrier to robot assembly vision station.

Merge:

Move base plate from palette to assembly position. Assemble instrument 1 from magazine 1 to base plate. Assemble instrument 2 from magazine 2 to base plate. Assemble pen holder from palette to base plate and split process plan into 2 parallel process parts (P3 and P4).

part P3:

Request a empty carrier from transport system (REQUIRE). Move empty palette from robot assembly vision station to transport carrier and transport palette to AS-RS. Store empty palette in AS-RS.

part P4:

Request a empty carrier from transport system (REQUIRE). Move palette with complete deskset from robot assembly vision station to transport carrier and transport palette to AS-RS. Store complete deskset in AS-RS

Merge:

end of process To execute sub-process 507 the following equipment is required: • • • • •

50

Transport system station Robot assembly vision station AS/RS station Pallet Type 1PH Pallet Type 1BP

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

6.3.7.

Sub-process 510

To produce a deskset with two instruments, one penholder aluminum and one pen the process plan is to split into 2 parallel process parts (P1 and P2) part P1:

Retrieve a unprocessed penholder (aluminum) from stock and transport the pallet to CNC-coupling station. Take the pallet from transport carrier to CNC-coupling station and process workpiece in turning machine. After processing unload part back on pallet and move pallet to robot assembly station.

part P2:

Retrieve a unprocessed base plate from stock and transport the pallet to CNCcoupling station. Take the pallet from transport carrier to CNC-coupling station and process workpiece in milling machine. After processing unload part back on pallet and move pallet to robot assembly station.

Merge:

Move base plate from pallet to assembly position. Assemble instrument 1 to base plate. Assemble instrument 2 to base plate. Assemble pen-holder from pallet position to base plate. Move base plate from assembly position to pallet. Split process plan into 2 parallel process parts (P3 and P4)

part P3:

Request a empty carrier from transport system (REQUIRE). Move empty pallet from robot assembly station to transport carrier. Transport pallet to AS-RS to store empty pallet in AS-RS.

part P4:

Request a empty carrier from transport system (REQUIRE). Move pallet with complete deskset from robot assembly station to transport carrier. Transport pallet to AS-RS to store complete deskset in AS-RS

Merge:

end of process

To execute sub-process 510 the following equipment is required: • • • • •

Transport system station Robot assembly vision station AS/RS station Pallet Type 1PH Pallet Type 1BP

© Festo Didactic GmbH & Co.KG. • FMS100

51

Operation

6.4. Start up Cosimir Control

If not happened, Start up COSIMIR CONTROL PC. For documentation the Columbia project serves as an example. 6.4.1.

Choose project

Double click COSIMIR CONTROL icon on desktop

Once the COSIMIR CONTROL display appears, a project can be chosen.

52

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

There are two ways for getting the project, the shortcut if the project has already been active, or the longer way with the File/Menu.

Shortcut / Columbia Project

Under File / Open choose the project

File Menu step 1

Under project choose Columbia.LPJ

File Menu step 2

C:\ProgramFiles\COSIMIRCONTROL\Projects\Columbia\Columbia.lpj (example)

© Festo Didactic GmbH & Co.KG. • FMS100

53

Operation

6.4.2.

Check adjustments

After activating the project, the following picture appears on the screen.

Ready for production

Before changing to production mode, it is necessary to check the devices!!

Check for KTPROFI Check for INFO Check for SERIAL

Device check

Check for KTPROFI Check for FILE_IO Check for ODBC_SQL Check for KTPROFI Check for MATFLOW Simula possible for training Must be adjusted like here

54

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

If the devices are not adjusted as shown in the picture, it is necessary to change them. First the COSIMIR CONTROL has to be changed to SETUP mode. Click on Setup button. Wait untill button is active. The following screens are just examples.

Change to SETUP mode

To activate the wrong device, click the corresponding icon

Choose the wrong device

Move the mouse on Off Line and click on it.

Activate the wrong device

Now it is possible to choose the right device.

Click on the correct device and it will be active. After check/adjust all devices, it is possible to check the drivers, libraries and process plans.

© Festo Didactic GmbH & Co.KG. • FMS100

55

Operation

Do not edit the drivers and libraries, they are adjusted while commissioning.

Here the drivers are listed

Here the libraries are listed

56

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

All sub processes are listed under the Process plans. Here it is possible to create a new process, in this example processes 1-11 are prepared for the customer.

Activated and prepared Process plans

© Festo Didactic GmbH & Co.KG. • FMS100

57

Operation

6.4.3.

Change to production

With the production button the production can be started. Click on the production button, and wait untill a new window is opened.

Start Info

Remove all pallets from the carriers and confirm info-box window with OK. Insert number of carriers, if working in simula mode. System is ready to start processes.

58

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

6.5.1.

6.5. COSIMIR CONTROL operation

Start-up of processes

At this point all of the stations are in automatic mode and completely operational. Existing or newly created processes can be started by means of the cell control. The colors of the stations, the carriers and the processes have different functions. For an easier understanding these functions are shown in the following picture.

Inactive station Active process

Inactive process

Occupied pallet reception Free pallet reception

Executing carrier

Occupied carrier

Clamped carrier ready for pallet Waiting carrier Expected carrier

Active Station Working position 2

Index unit Ix2

Actual task of active station

Stopper St2

Functions of the colors in COSIMIR CONTROL

© Festo Didactic GmbH & Co.KG. • FMS100

59

Operation

COSIMIR CONTROL after start up

In this example process 102 / 103 / 125 are programmed, process 1-11 are prepared for the customer. The carriers are green, that means the system is already started. For the example the process 102 is executed and described in the following.

Choose process 102

Click on the Process 102 button to choose this process.

60

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

Process describtion

Insert number of parallel processes. If parallel process is active, the system will execute the given “number of processes” simultaneously, but at max. as many as defined with “max.no. Parallel processes”. If parallel processes is not active, the number of processes will be executed sequencly.

Process description

Change to page two (not available for each process- here you get further information to the process descripten) Choose parallel processing if more than 1 process should be done parallel.

Insert number of max. Parallel processes (only possible if parallel processing mode is active) Real cutting on(if the workpiece should be processed). Choose type of cover (example octagonal with 36mm

Cancel or start process

Click on OK to start the process with the chosen settings.

© Festo Didactic GmbH & Co.KG. • FMS100

61

Operation

Process 102 is active

Now process 102 is active, the carrier (blue) which is clamped in front of the AS/RS is waitung for the pallet.

Clamp carrier at AS/RS

The different steps are announced at the screen. A Pallet with Partnumber 60200 is retrieved and moved on the waiting carrier.

62

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

Transport carrier to working position

The carrier with loaded part number 60 200 is transported to the CNC-coupling station.

Take pallet into CNC-coupling station

The pallet is picked up by the robot and moved to the reserved pallet reception on CNC-coupling station.

© Festo Didactic GmbH & Co.KG. • FMS100

63

Operation

Load and process workpiece

The workpiece is loaded into the CNC-milling machine and the carrier is released.

The workpiece is processed

The Emco CNC-machine is processing the workpiece.

64

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

The cycle to process the cylinders is done 4 times. After processing the workpiece number is changed into the new one.

Unload CNC-machine and take pallet on carrier

When all covers are processed, the pallet is removed on a carrier and stored back into the AS/RS.

store processed covers

After storing the parts, the process is ready.

© Festo Didactic GmbH & Co.KG. • FMS100

65

Operation

6.6. COSIMIR CONTROL further information

6.6.1.

Further information about the stations

For further information of the stations, there are some additional buttons. The CNC-machine solves as an example. Data acquisition CNCmachine

Click on Data Acq. for further information of the CNC-machine.

Data acquisition

The average usage and a picture of the station is shown under data acq. The data can be different, depending on the station.

Back to system Click on System and get back to main system view.

66

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

Infos CNC-Machine

Click on Info to get some more information of the CNC-machine.

Information CNC-milling machine

The process task and the device description of the station are shown under info. The information can be different, depending on the station.

Back to system Click on System and get back to main system view.

© Festo Didactic GmbH & Co.KG. • FMS100

67

Operation

Further information about the stations Process 102-4

Click on NEXT button and processes 5-11 are available

Process 5-11

Click on BACK button to get to process 102-4 and the main system view

68

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

6.6.2.

Further information about the zoom

Zoom functions

With the zoom it is possible to close up the different areas.

With a second click on zoom button, the main view will be shown.

© Festo Didactic GmbH & Co.KG. • FMS100

69

Operation

6.6.3.

Shut down COSIMIR CONTROL

Change COSIMIR window

Activate COSIMIR CONTROL window, click on COSIMIR button on window task bar.

Stop production

Click on PRODUCTION button to stop all production processes.

70

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

Wait for production end

Important: Wait!! Don’t click on buttons, the production will finish on its one.

Production finish

After production has stopped, and this window appears, it is possible to change again to production or to shut down the COSIMIR CONTROL program and the PC.

© Festo Didactic GmbH & Co.KG. • FMS100

71

Operation

6.7. COSIMIR CONTROL AS/RS Manager

The following project serves as an example. The operation for other projects is the same. It is also the same operation for AS/RS with 48 shelves.

Change to AS/RS Manager

The AS/RS-Manager is started automatically while starting COSIMIR CONTROL. To change into the AS/RS-Manger menu click on STOCK ADMINISTRATION button on the windows task bar.

AS/RS-Manager

72

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

Move one shelf backwards

Move to shelf 1

Move one shelf forwards

Move to shelf 40

Move in AS/RS-Manager

Black frame/active shelf

To choose a shelf it is possible to click directly onto the shelf, or move with the buttons to the chosen shelf. If a AGV is integrated in the system, shelf 13 is reserved for pallet handling. The reserved shelf 13 is marked with a blue frame like in the picture below.

© Festo Didactic GmbH & Co.KG. • FMS100

73

Operation

6.7.1.

Modify function

Modify parts

Click on chosen part – part is shown in detail shelf view. To edit a zone number, it is the same procedure.

Click on modify button to get into shelf edit mode.

74

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

Part ready for changes

Change partnumber

Click onto partnumber and change partnumber manually

Activate new settings

Click on update to take over the new settings

New settings

New settings are active.

© Festo Didactic GmbH & Co.KG. • FMS100

75

Operation

Reserve part

Click on MODIFY button, click on RESERVED field, insert 1 and click on update to activate the settings.

Reserved shelf

The key is the sign for a reserved shelf. Now it is not possible to retrieve or move the pallet of this shelf. If the shelf would be empty, it is not possible to store something in this shelf.

76

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

6.7.2.

Retrieve function / Search for part number

Click on RETRIEVE button to activate retrieve mode. Activate SEARCH FOR PART NUMBER / the first shelf witch is occupied with the chosen part number will give over the pallet.

Retrieve part 60 244

To retrieve a part, insert the chosen part number in field PART NO. ORDER NO. is always 0. Click on START button.

© Festo Didactic GmbH & Co.KG. • FMS100

77

Operation

Retrieve order active

Chosen part is reserved for retrieve.

Part is retrieved

Part is retrieved, shelf 12 is empty

78

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

6.7.3.

Retrieve function / retrieve shelf direct

Click on RETRIEVE button to activate retrieve mode. Activate RETRIEVE SHELF DIRECT / Choose shelf, insert number in field SHELF NO.

Retrieve shelf 10

To retrieve a part, insert the chosen shelf number in field SHELF NO. Click on START button.

Retrieve order active

Chosen shelf is reserved for retrieve.

© Festo Didactic GmbH & Co.KG. • FMS100

79

Operation

Part is retrieved

Part is retrieved, shelf 10 is empty

80

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

6.7.4.

Zoning

It is possible to devide the stock in different zones. So it is possible to store different parts in different zones of the stock. For example all black parts are in zone 1 (shelf 1 to 8), all red parts are in zone 2 (shelf 9 to 16). In the main screen of the AS/RSManager, in edit mode, it is possible to edit the shelves and give them a zone number (see chapter modify function). The parts are edited in the product list. If the ENABLE ZONING button in store mode is active, the parts need a zone number. In this case it is only possible to store the parts in the respective zone of the stock, if the zone numbers of the part and of the shelf are identical.

Open product list Click on PRODUCT LIST button to edit parts for zoning.

Edit part

Click on chosen part in product list. Change zone number in edit field, for example to 5. Click on UPDATE button to activate the new settings. New settings The new settings are active. Now part number 60 245 can only be stored in zone 5 of the stock. © Festo Didactic GmbH & Co.KG. • FMS100

81

Operation

6.7.5.

Store function / search for empty shelf

In store mode SEARCH FOR EMPTY SHELF there is an order ENABLE ZONING: it is possible to distribute the stock in different zones. If the ENABLE ZONING button is active, the parts need a zone number and it is only possible to store them in the respective zone of the stock. See chapter zoning. If the button is inactive, the parts are stored in the first empty shelf. Click on STORE button to activate store mode. Activate SEARCH FOR EMPTY SHELF and ENABLE ZONING.

Store part no 60245

To store a part, insert the chosen part number in field PART NO. The ORDER NO. is always 0. Click on the START button. The part will be stored in the first empty shelf.

82

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

Store order active

Shelf 7 is reserved to store part no. 60 245. It is the first empty shelf in stock.

Part 60 245 is stored

Part is stored in the first empty shelf.

© Festo Didactic GmbH & Co.KG. • FMS100

83

Operation

6.7.6.

Store function / store shelf direct

Click on STORE button to activate store mode. Activate STORE SHELF DIRECT.

Store part no 60245

To store a part, insert the chosen part number in field PART NO. The ORDER NO. is always 0, insert the chosen SHELF NO (Take care that the shelf is empty). Click on the START button.

84

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

Store order active

Shelf no.12 is reserved to store part no. 60 245.

Part 60 245 is stored

Part is stored in shelf no. 12

© Festo Didactic GmbH & Co.KG. • FMS100

85

Operation

6.7.7.

Move part

Click on the MOVE button to activate move mode.

Move part no 62 101 from shelf 27 to shelf 14

To move a part, insert the actual shelf number of the chosen part in field SOURCE SHELF, insert the number of the destination shelf into DESTINATION SHELF field. Click on START button.

Move order active

Shelf number 27 and 14 are reserved to move part number 62 101.

86

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

Part 62 101 is moved

Part number 62 101 is moved from shelf 27 to shelf no. 14

© Festo Didactic GmbH & Co.KG. • FMS100

87

Operation

6.7.8.

First time init

To get initial conditions the button FIRST TIME INIT has to be activated. If the function is executed, the stock is in original conditions. These conditions depend on the project.

Start first time init

Click on FIRST-TIME-INIT button to start the first time initial mode.

Confirm window

Confirm with yes and OK button to start first time init.

88

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

New conditions

New conditions are active, Click on OK to continue.

© Festo Didactic GmbH & Co.KG. • FMS100

89

Operation

6.7.9.

Edit Product list

It is possible to edit available parts or to insert new parts in product list. Product classes

No parts No processed parts Processed covers Processed cylinders Palette for clinders Palette for Covers Change to product list.

Open product list Click on button PRODUCT LIST button to edit parts.

Edit part

Click on chosen part in product list. Change settings in edit field, for example change zone number from 1 to 5. Click on UPDATE button to activate the new settings. New settings The new settings are active. Part number 60 245 is configured for zone 5.

90

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

Create new part

To create a new part, click on NEW button.

Edit settings for new part

Insert settings for new part in edit field.

Save settings

Save settings for new part. Click on SAVE button.

© Festo Didactic GmbH & Co.KG. • FMS100

91

Operation

New product is active

The new product is active.

Delete part

To delete a part, activate the part and click on DELETE button.

92

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

6.7.10.

Trouble shooting / AS-RS-Manager

RETRIEVE mode / SEARCH FOR PART NUMBER

No entry found in database

No entry found in database - There is no part with the chosen part number in the stock.

Confirm message

Confirm message and insert new part number.

© Festo Didactic GmbH & Co.KG. • FMS100

93

Operation

6.7.11.

RETRIEVE mode / RETRIEVE SHELF DIRECT

No part available

No part available in selected source shelf - There is no part in chosen shelf. Confirm message and insert new shelf number.

Wrong zoning number

The zoning number is wrong, edit zoning number from shelf or part. Confirm message and edit zoning number.

94

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

Destination shelf occupied

Move order, destination shelf already occupied, confirm message, edit destination shelf. Take care that destination shelf is free.

Wrong partnumber

The part number is wrong, there is no part with this number in product list. Confirm message, insert new part number or edit product list and create a new part.

© Festo Didactic GmbH & Co.KG. • FMS100

95

Operation

6.8. Order codes Transport system stoppers PLC – COSIMIR CONTROL

Station

Type / Parameter

Nr.

Description

Available

Ordernumber/ Orderdescription 16 # 1031

Parameter 1

16#0001

Function code Release stopper

Parameter 2

ST1

Parameter 3

Station

X

Return code

65535

Invalid input parameters

x

Type / Parameter

Nr.

Description

Available

Ordernumber/ Orderdescription 16 # 1032

Parameter 1

16#0001

Function code Release stopper

Parameter 2

ST2

Parameter 3

Station

x

Return code

65535

Invalid input parameters

x

Type / Parameter

Nr.

Description

Available

Ordernumber/ Orderdescription 16 # 1033

Parameter 1

16#0001

Function code Release stopper

Parameter 2

ST3

Parameter 3

Station

x

Return code

65535

Invalid input parameters

x

Type / Parameter

Nr.

Description

Available

Ordernumber/ Orderdescription 16 # 1034

Parameter 1

16#0001

Function code Release stopper

Parameter 2

ST4

Parameter 3 Return code

96

65535

Invalid input parameters

x

x

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

6.9. Order codes Transport system hubix PLC – COSIMIR CONTROL

Station

Type / Parameter

Nr.

Description

Available

Ordernumber/ Orderdescription 16 # 1011

Parameter 1

16#0020

Function code Release hubix IX1

x

Parameter 2 Parameter 3

Station

Return code

65535

Invalid input parameters

x

Type / Parameter

Nr.

Description

Available

Ordernumber/ Orderdescription 16 # 1012

Parameter 1

16#0020

Function code Release hubix IX2

x

Parameter 2 Parameter 3

Station

Return code

65535

Invalid input parameters

x

Type / Parameter

Nr.

Description

Available

Ordernumber/ Orderdescription 16 # 1013

Parameter 1

16#0020

Function code Release hubix IX3

x

Parameter 2 Parameter 3

Station

Return code

65535

Invalid input parameters

x

Type / Parameter

Nr.

Description

Available

Ordernumber/ Orderdescription 16 # 1014

Parameter 1

16#0001

Function code Release hubix IX4

x

Parameter 2 Parameter 3 Return code

© Festo Didactic GmbH & Co.KG. • FMS100

65535

Invalid input parameters

x

97

Operation

6.10. Order codes AS/RS 40 PLC – COSIMIR CONTROL

Station

Type / Parameter

Nr.

Description

Available

Parameter 1

1

Shelf 1

X

Source position

2

Shelf 2

X

3

Shelf 3

X

4

Shelf 4

X

5

Shelf 5

X

……

Shelf 6 – Shelf 36

X

37

Shelf 37

X

38

Shelf 38

X

39

Shelf 39

X

40

Shelf 40

X

90

Position 90

X

91

Position 91

X

92

Position 92

X

93

Position 93

X

94

Position 94

X

Parameter 2

1

Shelf 1

X

Target position

2

Shelf 2

X

3

Shelf 3

X

4

Shelf 4

X

5

Shelf 5

X

……

Shelf 6 – Shelf 36

X

37

Shelf 37

X

38

Shelf 38

X

39

Shelf 39

X

40

Shelf 40

X

90

Position 90

X

91

Position 91

X

92

Position 92

X

93

Position 93

X

94

Position 94

X

0

No errors

X

No palette at source

X

Ordernumber/ Orderdescription 16 # 1100 Move pallet

Parameter 3 Type Return code

1 2 3

98

position Target position occupied

X

Telescope not in middle

X

position

15

Timeout

X

65535

Invalid input parameters

X

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

6.11. Order codes CNC-coupling station Drive Unit – COSIMIR CONTROL

Station Ordernumber/ Orderdescription StartPrg

Type / Parameter

Nr.

Description

Available

MP

Move palette

X

Parameter 1

1

Palette place 1

x

Source-

2

Palette place 2

X

position

15

Conveyor pickup/place position

X

Parameter 2

1

Palette place 1

X

Target

2

Palette place 2

X

position

15

Conveyor pickup/place position

X

0

No errors

X

1

No palette at source position

X

2

Target position occupied

X

10

Station not ready

X

15

Run-time error

X

30

Source position does not exist

X

40

Target position does not exist

X

65535

Invalid input parameters

x

Nr.

Description

Available

MCyl

Move cylinder

X

Parameter 1

1

Palette place 1

x

Source-

2

Palette place 2

X

position

3

Brass feeder (magazine)

X

Robot program name

Parameter 3 Return-Code

Station Ordernumber/ Orderdescription StartPrg

Type / Parameter

Robot program name

Parameter 2 Target position

4

Aluminum feeder (magazine)

X

1

Palette place 1

X

2

Palette place 2

0

No errors

X

1

No pallet at source position

X

2

No pallet at target position

X

3

No part at magazine

X

10

Station not ready

X

15

Run-time error

X

30

Source position does not exist

X

40

Target position does not exist

X

65535

Invalid input parameters

x

X

Parameter 3 Return-Code

© Festo Didactic GmbH & Co.KG. • FMS100

99

Operation

Station Ordernumber/ Orderdescription StartPrg#

Type / Parameter

Nr.

Description

Available

LMILL

Load milling machine

X

Parameter 1

1

Palette 1

X

Source-

2

Palette 2

X

position

5

Base plate feeder( Magazine)

X

0

No errors

X

1

No palette at source position

X

2

No part at feeder (magazine)

X

3

Run-time error milling machine

X

10

Station not ready

X

15

Run-time error

X

Robot program name

Parameter 2 Parameter 3 Return-Code

Station Ordernumber/ Orderdescription StartPrg#

Type /

30

Source position does not exist

X

65535

Invalid input parameters

X

Nr.

Description

Available

ULMILL

Unload milling machine

X

1

Palette 1

X

2

Palette 2

0

No errors

X

1

No pallet at target position

X

3

Run-time error milling machine

X

10

Station not ready

X

15

Run-time error

X

40

Target position does not exist

X

65535

Invalid input parameters

X

Parameter

Robot program name Parameter 1 Targetposition

X

Parameter 2 Parameter 3 Return-Code

100

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

Station Ordernumber/ Orderdescription StartPrg

Type /

Nr.

Description

Available

LTURN

Load turn

X

Parameter 1

1

Palette 1

X

Source-

2

Palette 2

X

position

3

Feeder brass pen holder

X

4

Feeder aluminium pen holder

X

0

No errors

X

1

No palette at source position

X

2

No part at magazine

X

3

Run-time error turning machine

X

10

Station not ready

X

15

Run-time error

X

30

Source position does not exist

X

65535

Invalid input parameters

X

Parameter

Robot program name

Parameter 2 Parameter 3 Return-Code

Station Ordernumber/ Orderdescription StartPrg

Type /

Nr.

Description

Available

ULTURN

Unload turn

X

1

Palette 1

X

2

Palette 2

X

0

No errors

X

1

No pallet at target position

X

3

Run-time error turning machine

X

10

Station not ready

X

15

Run-time error

X

40

Target position does not exist

X

65535

Invalid input parameters

X

Parameter

Robot program name Parameter 1 Targetposition Parameter 2 Parameter 3 Return-Code

© Festo Didactic GmbH & Co.KG. • FMS100

101

Operation

6.12. Order codes Robot-vision assembly station Drive Unit – COSIMIR CONTROL

Station Ordernumber/ Orderdescription StartPrg

Type /

Nr.

Description

Available

MP

Move palette

X

Parameter 1

1

Palette 1

x

Source-

2

Palette 2

X

position

3

Palette 3

x

4

Palette 4

X

15

Conveyor pickup/place position

X

Parameter 2

1

Palette 1

X

Target

2

Palette 2

X

position

3

Palette 3

x

4

Palette 4

X

15

Conveyor pickup/place position

X

0

No errors

X

1

No palette at source position

X

2

Target position occupied

X

10

Station not ready

X

15

Time out

X

30

Source position does not exist

X

40

Target position does not exist

X

65535

Invalid input parameters

x

Parameter

Robot program name

Parameter 3 Return-Code

102

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

Station Ordernumber/ Orderdescription StartPrg

Type / Parameter

Nr.

Description

Available

MBP

Move base plate

X

Parameter 1

1

Palette 1

X

Source-

2

Palette 2

X

position

3

Palette 3

X

4

Palette 4

X

81

Assembly position

X

Parameter 2

1

Palette 1

X

Target

2

Palette 2

X

position

3

Palette 3

X

4

Palette 4

X

5

Assembly position

X

0

No errors

X

1

No palette at source position

X

2

Target position occupied

X

3

Assembly position occupied

X

10

Station not ready

X

15

Time out

X

30

Source position does not exist

X

40

Target position does not exist

X

65535

Invalid input parameters

x

Robot program name

Parameter 3 Return-Code

© Festo Didactic GmbH & Co.KG. • FMS100

103

Operation

Station Ordernumber/ Orderdescription StartPrg

Type /

Nr.

Description

Available

ASMPH

Assemble pen holder

X

Parameter 1

1

Palette place 1

X

Source-

2

Palette place 2

X

position

3

Palette place 3

X

4

Palette place 4

X

0

No errors

X

1

No palette at source position

X

2

No base plate clamped

X

10

Station not ready

X

15

Time out

X

Parameter

Robot program name

Parameter 2 Parameter 3 Return-Code

Station Ordernumber/ Orderdescription StartPrg

Type / Parameter

30

Source position does not exist

X

65535

Invalid input parameters

x

Nr.

Description

Available

ASMFF

Assemble magnet from feeder

X

1

Feeder 1 (magazine 1)

Robot program name Parameter 1 Sourceposition Parameter 2 Target position

2

Feeder 2 (magazine 2)

1

Assembly position 1

X X X X

2

Assembly position 2

0

No errors

1

No part in feeder (magazine)

X

2

No base plate clamped

X

3

Test place occupied

4

No orientation found

10

Station not ready

15

Time out

X

30

Source position does not exist

X

65535

Invalid input parameters

x

Parameter 3 Return-Code

104

X

X

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

Station Ordernumber/ Orderdescription StartPrg

Type / Parameter

Nr.

Description

Available

ASMP

Assemble pen

X

0

No errors

X

2

No base plate clamped

X

10

Start

X

15

Time out

X

65535

Invalid input parameters

x

Robot program name Parameter 1 Parameter 2 Parameter 3 Return-Code

© Festo Didactic GmbH & Co.KG. • FMS100

105

Operation

6.13.

Cell control

Each station of the installation is equipped with its own control, though for an efficient and complete process the station controls require to be coordinated on a higher level. This co-ordination ensues via iCIM by means of the SCADA system COSIMIR CONTROL.

Order interface

The co-ordination of the station controls is actuated by orders, which are sent from SCADA, by means of Profibus, to the station controls. All of the orders are processed in accordance with the same principle: • • • •

SCADA sends order to station, incl. parameter Station acknowledges order with ACK (or NACK) Station in operation Station reports conclusion of order, incl. parameter

As soon as the individual stations are set up, the order interfaces in the station controls are activated from the cell control. The cell control tests the status of the stations in a 5 second interval, in case the cell control is activated before completion of the loading of the station controls. The order interfaces are activated, as soon as the stations are fully in operational starting position. If the cell control is not loaded, the station controls remain in STAND ALONE mode. No reciprocal synchronization ensues. At this point the stations can be started from the control desk.

106

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

6.14.

Partnumbers

All part numbers ever used in iCIM – System are described in the following. Partnumber

Description

Class

42000

Cylindrical raw material, Alu, d=30mm, l=80mm

1

42001

Cylindrical raw material, Brass, d=30mm, l=80mm

1

42010

Raw material, base plate, Alu, l=140mm, w=

1

42100

Penholder, Alu, Type 1

2

42101

Penholder, Alu, Type 2

2

42102

Penholder, Alu, Type 3

2

42103

Penholder, Alu, Type 4

2

42104

Penholder, Alu, Type 5

2

42120

Penholder, Brass, Type 1

2

42121

Penholder, Brass, Type 2

2

42122

Penholder, Brass, Type 3

2

42123

Penholder, Brass, Type 4

2

42124

Penholder, Brass, Type 5

2

42140

Base plate for deskset, Alu, Type 1

2

42141

Base plate for deskset, Alu, Type 2

2

42142

Base plate for deskset, Alu, Type 3

2

42143

Base plate for deskset, Alu, Type 4

2

42144

Base plate for deskset, Alu, Type 5

2

52000

Deskset Type 1 ( 2 Magnets, 1 Penholder Brass Type 1 without Pen )

3

52001

Deskset Type 2 ( 2 Magnets, 1 Penholder Alu Type 1, 1 Pen )

3

52002

Deskset Type 3 ( 2 Instruments, 1 Penholder Alu Type 1, 1 Pen )

3

52003

Deskset Type 4 ( 1 Magnet, 1 Instrument, 1 Penholder Brass Type 1, 1 Pen )

3

52004

Deskset Type 5 ( 2 Instruments, 1 Penholder Brass Type 1, 1 Pen )

3

62200

Empty pallet for 1 cylindrical workpiece

4

62201

Empty pallet for 1 base plate

5

© Festo Didactic GmbH & Co.KG. • FMS100

107

Operation

108

Program

Program

mill

turn

Penholder, Alu, Type 1

61

40

X

42101

Penholder, Alu, Type 2

61

40

X

42102

Penholder, Alu, Type 3

61

40

X

42103

Penholder, Alu, Type 4

61

40

X

42104

Penholder, Alu, Type 5

61

40

X

42120

Penholder, Brass, Type 1

61

40

X

42121

Penholder, Brass, Type 2

61

40

X

42122

Penholder, Brass, Type 3

61

40

X

42123

Penholder, Brass, Type 4

61

40

X

42124

Penholder, Brass, Type 5

61

40

X

42140

Base plate for deskset, Alu, Type 1

62

40

X

42141

Base plate for deskset, Alu, Type 2

62

40

X

42142

Base plate for deskset, Alu, Type 3

62

40

X

42143

Base plate for deskset, Alu, Type 4

62

40

X

42144

Base plate for deskset, Alu, Type 5

62

40

X

Partnumber

Description

42100

Available

© Festo Didactic GmbH & Co.KG. • FMS 100

Operation

6.15. Workpiece direction

Transport direction work piece carrier example

© Festo Didactic GmbH & Co.KG. • FMS100

109

Operation

110

© Festo Didactic GmbH & Co.KG. • FMS 100

7. Pneumatic

With the help of pneumatic cylinders, axes and grabs, the workpieces and the workpiece carriers get clamped, distributed or just moved. The valve terminal necessary for the control, consist from different, the use purpose, individual valves. The cylinders and the valves are described in the following. 7.1. The valve terminal

Example Valve terminal

Pos.

Name

1

Odernumber

18 200

2

Ordername

10P-10-6B-IC-N-V-2M4J+HZ

© Festo Didactic GmbH & Co.KG. • FMS 100

111

Pneumatic

7.2. Pneumatic supply

The pressure in the supply line must not exceed 10 bar. A fine filter has to be installed, to prevent contamination by rust or similar. A stop cock is required for the supply of the installation. The pressure regulators should be set in between 5 and 6 bar. The filter and water separators require maintenance according to the instructions of the documentation of these components. The exact allocation of the valve terminal can be found in the pneumatic plan.

Service unit

112

© Festo Didactic GmbH & Co.KG. • FMS 100

8. Electrical system

To operate the system it is required to connect all of the supply cables and communication lines included. The cables used to program the system are explained additionally. To give you a better overview of the being lines used in the plant, these are explained in the following. 8.1. Power supply

The devices are delivered together with the respective power supply plugs, protectively contact covered, in case they require power supply. The customer must ensure that the power supply is earthed correctly and is equipped with a fault current monitor. If it is required for several devices to be in operation at the same time, it is possible to connect these to a switchboard containing distribution board, provided that the permissible maximum rating is not exceeded. Each station contains its own individual EMERGENCY STOP switch, which at first reacts to its respective station only. It has to be clarified in advance, if a central ROOM EMERGENCY STOP switch is required.

© Festo Didactic GmbH & Co.KG. • FMS 100

113

Electrical system

8.2. Controller example

The control of the stations can be taken on by different control types. An example is described in the following. The function and the sequence of the processes are the same. 8.2.1.

Controller design S7

No.

Card location

Module

Name

Comment

1

2

Controller

CPU-313C

3

For operation panel

2

4

For I/O communication

3

5

IT-card

CP343-1IT

For Ethernet communication

4

6

Servo card

FM 354

For x-axis

5

7

Servo card

FM 354

For y-axis

7

8

Servo card

FM 354

For handling / z-axis

S7 controller example

The communication ensues by means of Ethernet, should the station be connected to another station, as described under the point complete process, for example. Two possibilities are available to program the Siemens controls. A MPI cable is sufficient for programming, if a special programming unit is available. If a common PC is used for programming, a MPI card needs to be installed into the PC. If such a card containing PC is available, a common MPI cable may be used. A MPI cable inclusive adapter box is required, if a PC without MPI card is used for programming. The interface for programming is on the CPU313 –Card.

114

© Festo Didactic GmbH & Co.KG. • FMS 100

Electrical system

8.3. Electrical components

The wiring within the station and the wiring to the other stations are explained in the following. 8.3.1.

I/O-Components

The operating strip, the modules from the profile plate and the z-axis are pluggable connected via I/O-terminals to the SM323 I/O-cards from the control. So that a perfect communication can be ensured, the I/O interface is standardized. The I/O terminal is at all work positions at the disposal.

I/O-Terminal

Technical data

© Festo Didactic GmbH & Co.KG. • FMS100

Plug type

IEEE 488 24 pins

Inputs

8

Outputs

8

Current consumption

Max. 1A/PIN

Power supply

24 VDC

115

Electrical system

OUT BIT 0 OUT BIT 1 OUT BIT 2 OUT BIT 3 OUT BIT 4 OUT BIT 5 OUT BIT 6 OUT BIT 7 POWER 24 VDC POWER 24 VDC POWER 0 VDC POWER 0 VDC

1 2 3 4 5 6 7 8 9 10 11 12

13 14 15 16 17 18 19 20 21 22 23 24

IN BIT 0 IN BIT 1 IN BIT 2 IN BIT 3 IN BIT 4 IN BIT 5 IN BIT 6 IN BIT 7 POWER 24 VDC POWER 24 VDC POWER 0 VDC POWER 0 VDC

syslink pin assignment 01 02 03 04 05 06 07 08 09 10 11 12

Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 24 V

Output word Output word Output word Output word Output word Output word Output word Output word Power supply

white brown green yellow grey pink blue red black

0 V Power supply pink-brown 0 V Power supply purple

13 14 15 16 17 18 19 20 21 22 23 24

Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 24 V

Input word Input word Input word Input word Input word Input word Input word Input word Power supply

0 V Power supply

grey-pink red-blue white-green brown-green white-yellow yellow-brown white-grey grey-brown white-pink white-blue

Allocation I/O- Terminal

Clamp

Bit

Function

Colour

Clamp

Bit

Function

Colour

01

0

Output

White

13

0

Input

Grey-pink

02

1

Output

Brown

14

1

Input

Red-blue

03

2

Output

Green

15

2

Input

White-green

04

3

Output

Yellow

16

3

Input

Brown-green

05

4

Output

Grey

17

4

Input

White-yellow

06

5

Output

Pink

18

5

Input

Yellow-brown

07

6

Output

Blue

19

6

Input

White-grey

08

7

Output

Red

20

7

Input

Grey-brown

24V

Power supply

Black

21

24V

Power supply

White-pink

09

10 11

12

116

22 0V

Power supply

Pink-brown

23

0V

Power supply

purple

24

0V

Power supply

White-blue

© Festo Didactic GmbH & Co.KG. • FMS 100

Electrical system

8.3.2.

ASI

There is an ASi-circuit to the control of the transport system. The ASi participants are connected to the control over an ASi cable which is yellow and protected by its form against incorrect polarity. The number of ASi participants is restricted, at most 31 participants can be attached at one ASi-circuit.

Example Asi-wiring

© Festo Didactic GmbH & Co.KG. • FMS100

117

View more...

Comments

Copyright ©2017 KUPDF Inc.
SUPPORT KUPDF