Jump Start: Assay Management in Aspen HYSYS ® Petroleum Refining A Brief Tutorial (and supplement to training and online documentation)
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-8225-1215
Jump Start: Assay Management in Aspen HYSYS ® Petroleum Refining
Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Scope of this Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Example Cases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Assay Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Adding a New Assay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Manually Creating an Assay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Characterizing Assays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Molecular Characterization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Reporting Assay Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Reporting Individual Assay Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Plotting Assay Comparison Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Exporting Assay Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Assays in the Simulation Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Attaching an Existing Assay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Creating a New Assay on a Stream . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Additional Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-8225-1215
b
Jump Start: Assay Management in Aspen HYSYS ® Petroleum Refining
Introduction The new Assay Management features in Aspen HYSYS Petroleum Refining allow users to utilize the same assay library and tools previously only available to Aspen PIMS users. These new features make crude characterization and management consistent across Aspen HYSYS and Aspen PIMS, maximizing opportunities for optimization. Assay Management allows users to: • Use the same assays in Aspen HYSYS Petroleum Refining and Aspen PIMS • Get better results for crude modeling using the improved characterization and property calculations of Aspen Assay Management • Access an extensive database of crudes and crude properties with the new assay library, and easily import data from other sources These features are now part of Aspen HYSYS Petroleum Refining, allowing users to seamlessly integrate it with existing Aspen HYSYS models for refinery simulation, as well as the planning capabilities of Aspen PIMS.
Scope of this Document This document is intended as a “getting started” guide. It will cover the process of adding an assay to an Aspen HYSYS Petroleum Refining model, characterizing it, and integrating it with the complete process simulation. It will also show you how to generate plots and extract information about these assays for review. It is not meant as a standalone reference document. We recommend pairing this guide with a range of other resources, including: • AspenTech knowledgebase items, training, and sample models available in aspenONE® Exchange • AspenTech Computer Based Training modules available from within Aspen HYSYS • AspenTech support website (support.aspentech.com) • AspenTech courseware available in on-line and in-person versions • AspenTech Business Consultants Knowledge of Aspen HYSYS V8 is assumed for this guide. Aspen HYSYS V8.4 needs to be installed for access to the functionality. If you do not know how to build a flowsheet in Aspen HYSYS, you should first consult reference material on this subject. We recommend the following: • Jump Start Guide: Getting Started with HYSYS V8 • AspenTech support website (support.aspentech.com) • Computer Based Training Module: Getting Started with Aspen HYSYS • Aspen HYSYS training course
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-8225-1215
1
Jump Start: Assay Management in Aspen HYSYS ® Petroleum Refining
Example Cases A sample Assay Management case named “REFSYS CDU DEMO BACKBLENDED ASSAY.hsc” is available in the Samples folder within Aspen HYSYS V8.4 and should be used for evaluating assay data. For this Jump Start Guide, we will be creating a HYSYS Petroleum Refining model from the beginning and adding the crude assay.
Assay Setup When setting up a refining case in Aspen HYSYS Petroleum Refining, the first step is to select and characterize crude assays. This is done within the HYSYS Properties Environment and will determine the characteristics of the incoming crude feeds before they can be used in the Simulation Environment. If a user has not defined a complete property package before creating a new assay, a default component list with hypothetical components and the Peng-Robinson fluid package will automatically be created and attached to the newly created assay.
Adding a New Assay First, we need to import the petroleum assay, using the “Petroleum Assays” button, as shown in Figure 1. This will take you to the HYSYS Petroleum Refining Assay Summary form where you can view and add assays to your case. By opening this page, you will get access to the Assay Management ribbon as shown in Figure 2. Here, you can find the “New Assay” button in the far left. Click on the dropdown arrow to select between these options: • Import from Library – Select an assay from the Assay Library • Import from File – Import a supported Excel, CSV, or .AFAM case with assay data • Manually Enter – Manually enter data into the Assay Table By default, clicking on the “New Assay” button will select the “Import from Library” option.
Figure 1: The Petroleum Assays button, located in the Home tab in the Properties Environment
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-8225-1215
2
Jump Start: Assay Management in Aspen HYSYS ® Petroleum Refining
Figure 2: The HYSYS Petroleum Refining Assay Summary form
Once the Assay Library has opened, there will be a large number of assays to select from and multiple ways to filter the results. In this example, we will import an existing assay from the Assay Library called Bachaquero crude. To find the specific crude to use in this case, type the name “Bachaquero” under “Assay name” and select the correct crude from the list, which will then be highlighted in yellow. To finalize the selection, click “OK” in the bottom-right corner, as shown in Figure 3. After the assay has been imported, you can verify stream properties by checking the “Input Assay” and “Conventional Results” plys in the left-hand Navigation Pane under the Assay name.
Figure 3: The window for selecting crudes from the assay library
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-8225-1215
3
Jump Start: Assay Management in Aspen HYSYS ® Petroleum Refining
Manually Creating Assays Since there are a variety of ways that assay information can be entered into a refining model, Aspen HYSYS Petroleum Refining provides a way for users to manually enter assay data by choosing the Manually Enter option when creating a new assay. This will open up the New Assay window, giving a number of custom options to format your assay table, as shown in Figure 4.
Figure 4: Options for manually entering assay data
There are three options to enter assay data: • Multi Cut Properties – This is ideal if you have data for specific assay cuts that you wish to enter, such as Cut Yields. Here, you can set the number of cuts from your data and enter the boiling point ranges in the table provided. • Single-stream Properties – This option is ideal if you want to evaluate an assay from distillation data and bulk (whole crude) properties to create a single-stream for your model. • Backblending – This will open a custom form designed specifically for users who have data from product streams and wish to simulate a backblended feed by entering pure component, distillation, and property data for specific products.
Characterizing Assays Under the Assay Management tab, there are also options for different assay characterizations using the “Characterize” button. The options include matching assay cut properties and whole crude properties, and molecular characterization, as shown in Figure 5. The default option to characterize when clicking the characterize button will be to match the Whole Crude properties given in the Input Assay table, which means matching the bulk values that have been given by the user will take precedence over matching values for specific cuts.
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-8225-1215
4
Jump Start: Assay Management in Aspen HYSYS ® Petroleum Refining
Figure 5: Different options for assay characterization, including matching assay cut properties
The tables shown under “Input Assay” can be customized with additional rows for other crude properties for each specified cut, as shown in Figure 6. The columns can also be customized, with new columns added for more custom cuts.
Figure 6: Option to include additional crude properties by adding rows to the Input Assay data table
Molecular Characterization When Molecular Characterization is selected, the user is given a list of hydrocarbon molecules present in the crude and is shown three editable columns: weight percent (Wt %), and the alpha and beta coefficients (Figure 7). In addition, viscosity coefficients are also available. These three variables can be modified prior to the molecular characterization step. Once they are selected, you can click the “Run Evaluation” button to characterize the assay using this data. After the assay has been characterized using Molecular Characterization, the user can change the characterization method by unchecking the “Molecular Characterization” box and using the “Characterize” button.
Figure 7: The Data Setup tab for Molecular Characterization
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-8225-1215
5
Jump Start: Assay Management in Aspen HYSYS ® Petroleum Refining
Reporting Assay Data A useful tool in the new Assay Management feature in Aspen HYSYS is the ability to plot assay data. This tool makes it easier to visualize the characteristics of a crude stream and it enables users to compare the features of several different crudes. The properties that can be plotted for assays are shown under the “Assay management” tab, in the “Plot Gallery” section.
Reporting Individual Assay Data When plotting data from an individual crude assay, you can select the desired plot from the gallery. In this example, we have plotted a distillation curve for the Bachaquero crude, as shown in Figure 8. You can change the graph’s coordinates, type, legend, text, etc. from the ribbon.
Figure 8: Distillation plot for Bachaquero crude
Plotting Assay Comparison Data To compare data from more than one crude assay, the second crude must be added—following the procedure we outlined earlier in this guide. In this example, we will compare Bachaquero and Shengli crudes. After Shengli has been added to the Petroleum Assays list, you can add it to the plot by clicking “Select Assays” under the Format tab when the Plot is selected, as shown in Figure 9.
Figure 9: The option to add more assays to a plot is possible using the “Select Assays” button, highlighted
When the additional assay is included in the plot, you can compare the properties—in this case the distillation curve of both assays side-by-side, as shown in Figure 10.
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-8225-1215
6
Jump Start: Assay Management in Aspen HYSYS ® Petroleum Refining
Figure 10: Plot showing the comparison between the Distillation curve for Bachaquero and Shengli
Exporting Assay Data Assays can be exported from a HYSYS Petroleum Refining case while in the Properties Environment. Go into the Petroleum Assays node to access the Assay Summary, select the assays to export, and click the Export button as shown in Figure 11. The assays can be saved as an AFAM case, which can be imported into another HYSYS Petroleum Refining case or Aspen PIMS for consistency of models for planning and engineering.
Figure 11: Form showing how to Export assays from a HYSYS Petroleum Refining case
Assays in the Simulation Environment The main goal of being able to bring in and create assays in Aspen HYSYS Petroleum Refining is being able to evaluate the behavior of various crudes within a refinery process model. There are a number of ways to use these assays and their results when using the new Aspen Assay Management. To begin using assays in the simulation, proceed to the Simulation Environment.
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-8225-1215
7
Jump Start: Assay Management in Aspen HYSYS ® Petroleum Refining
Attaching an Existing Assay When an assay has been created and characterized in the Properties Environment, it can be immediately used for modeling in the Simulation Environment. To bring the assay into the simulation, it must be either attached to a stream or added to a Petroleum Feeder unit operation. If the assay will be modeled as a single-stream, you can typically attach it to a material stream in the flowsheet. First, add a material stream to the flowsheet using the model palette. Then, open up the stream view by double-clicking the newly created stream and click on the “Petroleum Assay” option in the Worksheet tab. Once in the Assay form, select the Attach Existing option which will show a dropdown list where the previously created assay can be selected as shown in Figure 12. Once a characterized assay is attached, it will define the composition and the properties of the stream so that the user just has to enter the conditions of the stream for it to be fully defined. If more than one assay will be used or if the assay will be mixed with another stream, they can be added to a Petroleum Feeder, shown in the palette in Figure 13. In the Feeder, you can select input feed streams and feed assays (as well as mixing specifications including a fluid package) and Aspen HYSYS will calculate a product stream that can be used in the flowsheet.
Figure 12: Attaching an existing assay to a material stream
© 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-8225-1215
8
Jump Start: Assay Management in Aspen HYSYS ® Petroleum Refining
Figure 13: Petroleum feeder shown in the Refining palette
Creating a New Assay on a Stream In some cases, creating a new assay on a stream may be necessary. To do so, add a stream to the simulation and proceed directly to the “Petroleum Assay” option in the stream view. From this form, there are a number of options to add assays, similar to when creating an assay in the Properties Environment. The user can select Attach Existing, Import from File, Import from Library, or if they click the “Create” button, it will open the Manual Entry dialog for the user to begin entering assay data for the stream. Once the assay has been created on the stream, click the “View Assay” button at the bottom of the stream view at any time to open up the assay table for that specific stream. Figure 14 shows the view of the assay table while in the Simulation Environment.
Figure 14: Image showing the assay table in the Simulation Environment © 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-8225-1215
9
Additional Resources Public Website: http://www.aspentech.com/products/aspen-refsys.aspx
Aspen Online Training: http://www.aspentech.com/products/aspen-online-training
On-demand Short Presentations: Intro to Aspen HYSYS Petroleum Refining V8.4 https://www.brainshark.com/aspentech1/aspen-refsys-v84
Jump Start Tutorial Series: Jump Start: Aspen HYSYS V8.0 http://www.aspentech.com/JumpStart_HYSYSV8/
About AspenTech AspenTech is a leading supplier of software that optimizes process manufacturing—for energy, chemicals, pharmaceuticals, engineering and construction, and other industries that manufacture and produce products from a chemical process. With integrated aspenONE® solutions, process manufacturers can implement best practices for optimizing their engineering, manufacturing, and supply chain operations. As a result, AspenTech customers are better able to increase capacity, improve margins, reduce costs, and become more energy efficient. To see how the world’s leading process manufacturers rely on AspenTech to achieve their operational excellence goals, visit www.aspentech.com.
Worldwide Headquarters Aspen Technology, Inc. 20 Crosby Drive Bedford, MA 01730 United States phone: +1–781–221–6400 fax: +1–781–221–6410
[email protected]
Regional Headquarters Houston, TX | USA phone: +1–281–584–1000 São Paulo | Brazil phone: +55–11–3443–6261 Reading | United Kingdom phone: +44–(0)–1189–226400 Singapore | Republic of Singapore phone: +65–6395–3900 Manama | Bahrain phone: +973–17–50–3000 © 2015 Aspen Technology, Inc. AspenTech®, aspenONE®, the aspenONE® logo, the Aspen leaf logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. All other trademarks are property of their respective owners. 11-8225-1215
For a complete list of offices, please visit www.aspentech.com/locations