HVAC BOQ

May 31, 2016 | Author: Balu Chouhan | Category: Types, Research
Share Embed Donate


Short Description

VRF Unit Billing...

Description

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

SUMMARY OF COSTS FOR HVAC (VRF SYSTEM) WORKS GRAPHICS PVT. LTD. PUNE SR. DESCRIPTION OF WORKS NO.

Import Supply Amount (Rs)

Indegenious Supply Amount (Rs)

5,724,033

385,350

OPTION-1

1

PART - 1

A

VRF / VRV SYSTEM IMPORTED ITEMS

SUB TOTAL PART - 1

FOR FOR NVIDIA

5,724,033

09.06.12-R1 Installation Amount (Rs)

0

385,350

0

2,089,289

972,908

2

PART - 2

B

VRV / VRF SYSTEM (LOCAL ITEMS)

C

AIR DISTRIBUTION:

695,737

136,610

D

INSULATION

275,600

119,700

E

VENTILATION AND EXHAUST

32,613

5,700

3,093,239

1,234,918

3,478,589

1,234,918

SUB TOTAL PART - 2

GRAND TOTAL - PART - 1 + PART - 2

VAT @ 12.5% on Indegenious supply Service Tax @ 12.36% on Installation GRAND TOTAL Including taxes AMC cost for 1st year after warranty (DLP period) - for the above HVAC System (AMC costs shall be comprehensive)

Escalation in AMC cost / year for upto 4 years (%) after 1st AMC period (AMC costs shall be comprehensive)

5,724,033

434824 152,636 11,024,999

480000

7.50%

Note All above rates are all inclusive and with full taxes, duties, octroi (No exemption / Concession / Import Duty benefit is considered) for respective items. Note: 1. Supply of VRV equipments is exclusive of Import duty and VAT. Import duty NIL against STPI documents. VAT NIL against High sea sale agreement basis 2. Exchange rate: We have considered 1 USD =

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - Cost Summary

Page 1 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

P

SCHEDULE OF QUANTITIES FOR VRF SYSTEM WORKS FOR NVIDIA GRAPHICS PVT. LTD. PUNE PART-1 Import Supply SR. NO.

DESCRIPTION OF WORKS

QTY

A]

VRF / VRV SYSTEM IMPORTED ITEMS Supply of Out Door Units suitable for VRF / VRV System The system shall comprise of Outdoor Units with Air-cooled condenser suitable for operation at ambient temp. of 38oC., high pressure Scroll Compressors with hermetic motor, assembled and wired in a single package complete, starting controls, safety controls, operating controls and with full feature microcomputer based controller with real time clock and programming / diagnosis facility. The unit is to be given a complete factory operating and control sequence test under load conditions with fluid hooked up, and is to be shipped with full operating charge of refrigerant and oil. Aircooled Condensor, refrigeration-piping controls, first charge of refrigerant etc.

Installation

Indegenious Supply

UNIT RATE (Rs.)

1.0

Indegenious Supply

AMOUNT (Rs.) RATE (Rs.)

AMOUNT (Rs.)

RATE (Rs.)

SUPPLY QTY

SUPPLY AMOUNT

% OF CLAMING NOW

The Refrigerant used shall be any CFC free gas either R407C/ R410A refrigerant OR any other variant of CFC free refrigerant gas. The Outdoor units shall be complete as per technical specifications. One / All Compressors shall be fixed / inverter type based on manufacturer's technology. Outdoor units suitable for following capacities: 1.1

48 HP VRF ODU (12 HP x 4 nos.)

RO

Set

1.2

36 HP VRF ODU (12 HP x 3 nos.)

RO

Sets

1.3

32 HP VRF ODU

RO

Set

1.4

24 HP VRF ODU (12 HP x 2 nos.)

5

Set

1.5

18 HP VRF ODU

RO

Set

1.6

16 HP VRF ODU

RO

Set

1.7

14 HP VRF ODU

RO

Set

1.8

12 HP VRF ODU

RO

Sets

1.9

10 HP VRF ODU

RO

Set

1.10

8 HP VRF ODU

RO

Set

2.0

INDOOR UNITS Supply of Ductable, TFA, Cassette & Hi-Wall Type Units as follows in VRF / VRV System suitable for functioning with above outdoor units: Indoor Fan coil unit consisting of 3/4 row-cooling coil blower with motor, filters, drain pan & casing. The indoor unit shall be complete with all necessary controls including air and refrigerant temperature sensors and electronic expansion valves thus giving individual, variable refrigerant flow.

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 1

507943

2,539,715

5

2539715

100%

Page 2 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

PART-1 Import Supply SR. NO.

DESCRIPTION OF WORKS The electronic expansion valve shall be controlled by the ‘fuzzy logic’ microprocessor control system via a control board within the indoor unit that includes a unit address recognition system. Indoor Units to trip incase of fire signal. Units for critical rooms on N+1 basis shall work on sequential basis as specified. All Indoor units located above alse ceiling shall include the standard condensate pump kit as supplied by the manufacturer. Units below false ceiling level may require an additional condensate pump and shall be supplied by the installation contractor. The indoor unit shall be suitable for a power supply of 240V/ 1 phase/ 50Hz OR 415V / 3 phase / 50Hz. The indoor units shall be complete as per Technical Specifications and requirements as specified below.

2 4 4

Nos. Nos. Nos.

22503 24423 25246

45,006 97,692 100,984

2 4 4

45006 97692 100984

100% 100% 100%

250,840 125,596 260,936

4 2 4

250840 125596 260936

100% 100% 100%

145,341 633,204

3 13

145341 633204

100% 100%

493,170

10

493170

100%

54,796

1

54796

100%

852,372

4

852372

100%

50

385350

100%

4

8700

100%

2.2 2.2.1 2.2.2 2.2.3 2.2.4 2.2.5

4 way Cassette Type Indoor Units (MINI) 0.65 TR Cassette Unit (Mini) 0.8 TR Cassette Unit (Mini) 1.07 TR Cassette Unit (Mini) 1.33 TR Cassette Unit (Mini) 1.64 TR Cassette Unit (Mini)

4 2 4 RO RO

Nos. Nos. Nos. No. No.

62710 62798 65234 92093 96698

2.4 2.4.1 2.4.2 2.4.3 2.4.4 2.4.5 2.4.6 2.4.7 2.4.8 2.4.9

4 way Cassette Type Indoor Units 1.0 TR Cassette Unit 1.3 TR Cassette Unit 1.64 TR Cassette Unit 2.07 TR Cassette Unit 2.3 TR Cassette Unit 2.64 TR Cassette Unit 3.0 TR Cassette Unit 3.3 TR Cassette Unit 4.0 TR Cassette Unit

RO 3 13 RO 10 RO 1 RO RO

No. Nos. Nos. No. Nos. No. No. No. No.

48447 48447 48708 48708 49317 51926 54796 63545 72755

Treated Fresh Air Units with min. ESP 20 mm complete with hi performance filter of 90 % down to 10 microns TFA Unit - 650 CFM/4.0TR TFA Unit - 1000 CFM/6.4TR TFA Unit - 1250 CFM/8.0TR

RO 4 RO

No. Nos. No.

213093

VRV Accessories Multi Kits / Ref Joints

50

Nos.

3.0 3.1 3.2

Wired Controllers (only for Ductable and TFA IDU)

3.3

Remote Controllers for Cassette's & Hi-wall Units

3.4

Group Controllers with open protocol and BMS compatible with suitable software and accessories. Necessary integrator, convertor, software, hardware, license's etc. as applicable for the VRF / VRVs / SETFREE / MMS to interact & be controllable thru' central BMS. Necessary protocol for connecting with MODBUS RTU, BACNET, LONWORKS etc. shall also be included. Control Logic for working on working or standby basis shall also be included.

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 1

Indegenious Supply

UNIT

Hi-wall Type Indoor Units 1.07 TR / 350 CFM - H.W.U 1.66 TR / 525 CFM - H.W.U 2.07 TR / 700 CFM - H.W.U

2.5

Installation

QTY

2.1 2.1.1 2.1.2 2.1.3

2.5.1 2.5.2 2.5.3

Indegenious Supply

4

Sets

7707 2175

8,700

385350

To be Included Alongwith Respective Units RO

Sets

Quoted for Modbus Interface Card

Page 3 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

PART-1 Import Supply

Indegenious Supply

SR. NO.

DESCRIPTION OF WORKS

QTY

UNIT

3.5

Master Central Controller / Central Remote Controller with open protocol as specified below and in Technical Specifications suitable for automatic operation of all indoor and outdoor units. The central controller shall have a liquid crystal display (LCD) and have the capability of controlling all indoor & outdoor units individually, in groups and unanimously. The central controller shall have the unique capability of arranging indoor units into groups (up to 16 groups per network). Refer technical specifications for further details. The central controller shall be time clocked by the 7-day-Year round programmable timer supplied by the manufacturer or by an external time clock (supplied by others). When used in conjunction with the 7-day programmable timer then different programme on/off times for each group of indoor units shall be available.

1

Set

54796

54,796

1

Lot

60885

60,885

Installation

Indegenious Supply

1

54796

100%

60885

100%

The particular set of indoor units shall be controlled in sequence when working on N+1 basis. Indoor Units to trip in case of fire signal. Master Controller / Central Controller shall be capable for sequencing, programming scheduling the # no. of N+1 units for critical room for equal run, auto stand-by change over, fault take off etc. as specified. Incase of BMS system not in operation for any reason, the Master Controller / Central Controller shall be capable to work on stand alone basis and should be able to indicate and control all indoor and outdoor units as specified. 3.6

BACnet gateway with required control cabling to Central BMS with suitable software and accessories. Necessary integrator, convertor, software, hardware, license's etc. as applicable for the VRF / VRVs / SETFREE / MMS to interact & be controllable thru' central BMS. Necessary protocol for connecting with MODBUS RTU, BACNET, LONWORKS etc. shall also be included.

3.7

Grill for Cassette and other accessories

3.8 3.8.1 3.8.2 3.8.3 3.8.4 3.9

1

Included in Above for each equipment

OTHER CHARGES Port Clearance Freight Insurance Handling + lifting & shifting

incl incl incl incl

Lot Lot Lot Lot

Included in above

Any other charges the vendor feels is necessary

incl

Lot

To be Included in above

TOTAL FOR 'A' - VRF / VRV SYSTEM IMPORTED ITEMS

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 1

5,724,033

385,350

6,109,383

Page 4 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

PART-1 Import Supply SR. NO.

DESCRIPTION OF WORKS

QTY

Indegenious Supply

Installation

Indegenious Supply

UNIT

NOTE1 Rates shall be all inclusive NOTE2 MS supporting structure for Indoor and Outdoor Units etc. to be included with respective items. NOTE3 BMS & connectivity for these machines to be integrated with the Central BMS & to be included in above rates.

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 1

Page 5 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

SCHEDULE OF QUANTITIES FOR VRF SYSTEM WORKS FOR NVIDIA GRAPHICS PVT. LTD. PUNE Designing, engineering, fabricating and supplying, unloading, shifting, lifting of the following equipment / material and erection, testing and commissioning of the HVAC Low side works as under: Prices offered for Imported Equipment if any shall be based on CIF-Site basis. The break up this pricing for all taxes, duties, surcharge, freight, insurance, transport, loading and unloading etc. to be indicated seperately. For indigenious items & associated low side works, the Contractor shall indicate all inclusive pricing in the BOQ (indicate seperately in % of quantum, the Service Tax, Works Contract Tax and all other taxes, duties, VAT, levies etc., as applicable over base price. Octroi Amount as applicable shall also be indicated seperately.

PART-2 Indegenious Supply SR. NO.

DESCRIPTION OF WORKS

QTY

Indegenious Supply

UNIT RATE (Rs.)

B] 1.0

VRV / VRF SYSTEM (LOCAL ITEMS) Lifting Shifting, Erection, Installation, Testing and Commissioning of Out Door Units suitable for VRF / VRV System & including refrigerant gas & oil upto commissioning & warranty period. Shall also include for installation & commissioning of all Controllers.

1.1

48 HP VRF ODU (12 HP x 4 nos.)

RO

Set

1.2

36 HP VRF ODU (12 HP x 3 nos.)

RO

Sets

1.3

32 HP VRF ODU

RO

Set

1.4

24 HP VRF ODU (12 HP x 2 nos.)

5

Set

1.5

18 HP VRF ODU

RO

Set

1.6

16 HP VRF ODU

RO

Set

1.7

14 HP VRF ODU

RO

Set

1.8

12 HP VRF ODU

RO

Sets

AMOUNT (Rs.)

RATE (Rs.) AMOUNT (Rs.)

% OF CLAMING INSTALLATIO NOW N QTY

5

INSTALLATION AMOUNT

418100

1,425 1,425 1,425

2,850 5,700 5,700

2 4 4

2850 5700 5700

5,700 2,850 5,700

4 2 4

5700 2850 5700

4,275 18,525

3 13

4275 18525

14,250

10

14250

1,425

1

1425

10 HP VRF ODU

RO

Set

8 HP VRF ODU

RO

Set

2.0

2.1 2.1.1 2.1.2 2.1.3

Lifting Shifting, Erection, Installation, Testing and Commissioning of Indoor Units suitable for VRF / VRV System. Hi-wall Type Indoor Units 1.07 TR / 350 CFM - H.W.U 1.66 TR / 525 CFM - H.W.U 2.07 TR / 700 CFM - H.W.U

2 4 4

Nos. Nos. Nos.

2.3 2.3.1 2.3.2 2.3.3 2.3.4 2.3.5

4 way Cassette Type Indoor Units (MINI) 0.6 TR Cassette Unit (Mini) 0.8 TR Cassette Unit (Mini) 1.0 TR Cassette Unit (Mini) 1.33 TR Cassette Unit (Mini) 1.64 TR Cassette Unit (Mini)

4 2 4 RO RO

Nos. Nos. Nos. Nos. Nos.

1,425 1,425 1,425 1,425 1,425

2.4 2.4.1 2.4.2 2.4.3 2.4.4 2.4.5 2.4.6 2.4.7

4 way Cassette Type Indoor Units 1.0 TR Cassette Unit 1.3 TR Cassette Unit 1.64 TR Cassette Unit 2.0 TR Cassette Unit 2.3 TR Cassette Unit 2.64 TR Cassette Unit 3.0 TR Cassette Unit

RO 3 13 RO 10 RO 1

No. Nos. Nos. No. Nos. No. No.

1,425 1,425 1,425 1,425 1,425 1,425 1,425

12332 24664 24664

SUPPLY AMOUNT

418,100

1.9

6166 6166 6166

SUPPLY QTY

Installation

83,620

1.10

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 2

RABILL NO-1

Installation

Page 6 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

PART-2 Indegenious Supply Unit 2.4.8 SR. NO. 3.3 TR Cassette DESCRIPTION OF WORKS 2.4.9 4.0 TR Cassette Unit 2.5 2.5.1 2.5.2 2.5.3

Treated Fresh Air Units TFA Unit - 650 CFM/4.0TR TFA Unit - 1000 CFM/6.4TR TFA Unit - 1250 CFM/8.0TR

3.0

Electrical Works for VRF system

3.1

Power Distribution Panels for VRF ODU Supply, Installation, Testing & Commissioning of Power Distribution Panel for VRF ODU comprising of fully compartmentalised cubicle type panel, as per specifications and complete with : (Incoming Power with earthing from the bus bar box shall be provided to each of the distribution panels by HVAC contractor) i) Tinned Al. Busbars ii) 7 tank pre-treatment, Panel with IP 65 construction

RABILL NO-1

Installation

Indegenious Supply

RO QTY RO

No. UNIT No.

1,425 1,425

RO 4 RO

No. Nos. Nos.

1,425 1,425 1,425

5,700

9,497

18,994

Installation

4

5700

2

18994

iii) Oven baked epoxy paint finish or powder coated iv) Incoming and outgoing feeders v) Indicating and measuring instruments vi) Interconnections, interlocking, earthing etc. vii) Energy meter Panel Cost should include also OLP, SPP, On/ Off push buttons with On / Off / Trip indications, 3 nos. non polarised NO-NC contacts tripping on signal from fire dampers / fire alarm panel & BMS. Panel costs should include provision of Automatic Power Factor Correction (APFC) System for achieving 0.99 P.F. of following capacity to be installed in each of Panel for required capacitance), fully automatic in Auto mode and comprising of following: 1) Thyristorised zero crossing Real Time cycle To cycle Power factor correction system suitable for following kVAR in suitable steps with MPP capacitor 440 V AC as per IS13340 low watt loss in cylindrical model with externally fitted discharge resistors, earthing terminal, self healing type having over pressure safety interrupter mechanism. 2) Sensing unit displaying various electrical parameters like, input voltage, current, KVA demand, KW, Power factor, self dignostic error code indication with printout facility. 3) Fast response time of switching ON and OFF of capacitor : 40 mS set able. 4) Necessary control card to control firing of thyristors. 5) LED indication for number of capacitors banks steps switched on, power factor lag/lead should be available.

3.1.1

PDB (for VRF ODUs 24 HP x 2 + 12 HP x 1) Panel with IP 65 construction. (i) Incomer MCCB suitable for above mentioned VRF ODUs complete with capacitor bank of 20 kVAR in steps as stated above. (ii) Outgoing feeders a) suitable for 24 HP x 2 Nos. + 12 HP x with ELCB c) Spare feeder 1 no. 40 A ELCB

2

Sets

157214

3.2

Outdoor type Isolators with IP 65 enclosure for each VRF ODU

RO

No.

11561

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 2

314428

2

314428

100%

950

Page 7 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

PART-2 Indegenious Supply

Installation

SR. NO. DESCRIPTION OF WORKS Power & Control cabling: 3.3 Electrical contractor shall terminate power in individual IDU and switch socket as per requirement. For VRF ODU incoming power shall be provided at the PDB, from there to each VRF ODU the cabling shall be carried out by HVAC contractor.

QTY

UNIT

Control cabling with copper conductor min. 2 core x 1.5 sq.mm. cable with end termination for Indoor units with Plug Top, Earthing connection etc. (from indoor to outdoor & interconnecting control cabling)

1,090

RMT

2C x 1.5 sq.mm Cu. Armoured shielded cable, as per specs. (for BMS connectivity between ODU and Master Controller)

360

3.3.3

2C x 2.5 sq.mm Cu. Armoured conductor cable, as per specs.

RO

RMT

119

30

3.3.4

4C X 4 sq.mm Cu. Armoured conductor cable, as per specs

RO

RMT

167

31

3.3.5

4C X 6 sq.mm Cu. Armoured conductor cable, as per specs

120

RMT

301

3.3.6

4C X 10 sq.mm Cu. Armoured conductor cable, as per specs

RO

RMT

464

49

3.3.7

4C X 16 sq.mm Cu. Armoured conductor cable, as per specs

RO

RMT

711

49

3.4

Double Earthing with GI wire as required min. 8 SWG for Outdoor Units and Indoor Units as required.

1

LOT

12331

3.3.1

3.3.2

NOTE:

All Indoor and Outdoor units shall be provided with 3 m & 15 m of Power cord respectively with end termination and plug top / MCB at other end. All Cabling rates to include End terminations as per specifications.

4.0

Refrigerant piping Hard Copper refrigerant piping of required sizes for pair of gas (suction) & liquid, with 19 mm EPDM Closed Cell foam insulation material / 60 kg/m3 density for the gas line. The piping system must be supported at 1.75 m distance. Rates to include special damping and supporting system including installation of factory made joints as required. tray Outdoor piping on Terrace to be provided with ladder type tray for below and GI cover on the top. Gas Liquid 41.3 mm dia 22.2 mm dia 41.3 mm dia 19.1 mm dia 38.1 mm dia 15.9 mm dia 34.9 mm dia 19.1 mm dia 31.7 mm dia 15.9 mm dia 28.6 mm dia 15.9 mm dia 28.6 mm dia 12.7 mm dia 25.4 mm dia 12.7 mm dia 22.2 mm dia 19.1 mm dia 22.2 mm dia 12.7 mm dia 22.2 mm dia 9.5 mm dia 19.1 mm dia 9.5 mm dia 15.9 mm dia 9.5 mm dia

4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10' 4.11 4.12 4.13

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 2

RO RO RO 260 RO 20 80 20 20 40 10 20 480

RMT

RMT RMT RMT RMT RMT RMT RMT RMT RMT RMT RMT RMT RMT

135

190

3207 3086 2738 2274 2062 1802 1432 1312 1466 1190 1104 984 867

147150

68400

36120

12331

591240 36040 114560 26240 29320 47600 11040 19680 416160

RABILL NO-1

72

101

43

3,799

323 323 323 323 323 323 285 285 323 285 285 285 285

Indegenious Supply

Installation

78,480 1090

147150

100%

1090

78480

182

34580

100%

182

18382

114

34314

100%

114

4902

1

12331

100%

1

3799

83,980

260

591240

100%

260

83980

6,460 22,800 5,700 6,460 11,400 2,850 5,700 136,800

20 13

36040 17900

100% 100%

20 13

6460 3562.5

40

47600

100%

40

11400

232

201144

100%

232

66120

36,360

5,160

3,799

Page 8 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

PART-2 Indegenious Supply 4.14 SR. NO. 4.15 4.16 4.17

15.9 mm dia DESCRIPTION 6.4OF mm dia WORKS 12.7 mm dia 9.5 mm dia 12.7 mm dia 6.4 mm dia (Any other size the vendor feels is necessary for the ODUs)

5.0 5.1

Drain Piping Drain piping in hard PVC with all fittings, supports and clamps upto 80 mm dia. including drilling hole in wall chipping wall etc to conceal and to route the drain pipe. The piping shall be suitably insulated with 19 mm thk Closed cell foam insulation Class O stuck with approved adhesive compound. The insulation shall be covered with glass cloth and painted with rubberised paint.

5.2

GI 'B' class make up / drain piping with elbows, bends, tees, cleanouts etc. from pipe sizes 19 mm upto 80 mm dia (without insulation) complete as per Technical Specifications. The piping shall be suitably insulated with 19 mm thk Closed cell foam insulation Class O stuck with approved adhesive compound. The insulation shall be covered with glass cloth and painted with rubberised paint.

C]

AIR DISTRIBUTION: GSS DUCTING Rectangular / Circular Ducting in Galvanised Steel

Installation

Indegenious Supply

20 QTY 20 RO RO

RMT UNIT RMT RMT RMT

786 605 525

15720 12100

285 247 247

5,700 4,940

350

RMT

370

129500

133

46,550

RO

RMT

838

Installation

350

129500

100%

350

46550

82,080 27,360

240 137

173280 106489

100% 100%

240 137

41040 23375.7

7,600

29

32146

100%

29

5434

285

2,089,289

TOTAL FOR 'B' - VRF / VRV LOCAL ITEMS

1.0

RABILL NO-1

972,908

Supply, fabrication, installation and testing of GSS metal ducts as per IS-277 (120 GSM both sides, LFQ & confirming to Class VII) for GS Sheets and IS-655 for fabrication of following thicknesses including necessary G.I. hangers/ supports, volume control duct dampers, accessories, vanes, 3 mm neoprene rubber gasket etc. complete as per specifications in accordance with the approved shop drawings.

1.1 1.2 1.3 1.4 1.5

Ducts to be sent in Factory fabricated in Box form at the jobsite. Site work shall be limited to assembly, installation and suit to site pieces and collars/ droppers. The factory fabricated ducts shall be as per approved make list only. The quoted costs should include: i) Ducts with reinforcement/ strengthening ii) Air tight joints iii) Accessories such as splitter, damper, guide vane etc. iv) Hangers and supports v) Painting with Black color paint for duct sides behind the grills. vi) The gasket used in case for all ducts shall be fire retardant type vii) Ducts shall be fully sealed with Silicon Sealant for leak tight installation. 0.50 mm (26 SWG) GSS ducting 0.63 mm (24 SWG) GSS ducting 0.80 mm (22 SWG) GSS ducting 1.00 mm (20 SWG) GSS ducting 1.25 mm (18 SWG) GSS ducting

2.0

FLEXIBLE DUCTS

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 2

480 160 RO 40 RO

Sq.M. Sq.M. Sq.M. Sq.M.

722 779 938 1124 1310

346560 124640 44960

171 171 171 190 190

Page 9 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

PART-2 Indegenious Supply Testing OF and Commissioning of SR. NO. Supply, Installation, DESCRIPTION WORKS insulated flexible ducts. The insulated flexible duct shall have inner core made of double lamination of metalized polyster film permenantly bonded to a coated spring steel wire helix.

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 2

QTY

Installation

RABILL NO-1 Indegenious Supply

Installation

UNIT

Page 10 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

PART-2 Indegenious Supply of minimum 14 kg.cu.m. density SR. NO. Fibreglass insulation DESCRIPTION OF WORKS having a R-value 4.2oF-Ft2-hr/btu and 25 mm thk shall be wrapped over the inner core and covered with stronger outer jacket cum vapor barrier made of fibreglass reinforced metalized polyester film laminate.

2.1 2.2 2.3

The insulated flexible duct should be fire retardant type. Limit Flexible Duct to not more than 3 Ft Length for Diffuser Connection Insulated Flexible ducts of 75 mm dia Insulated Flexible ducts of 100 mm dia Insulated Flexible ducts of 150 mm dia

3.0

DUCTING ACCESSORIES Supply, fabrication, assembling, installation, adjusting & testing of air distribution accessories of assorted size as specified and shown on the drawing:

3.1

Volume Control Dampers Supply, installation and adjusting of GSS Volume Control Damper within ducts complete with suitable links, levers. Blades should be opposed blades.The blades should be mounted in nylon bushes operated by an interior wheel gear system. Manual quadrant control with position indicator to be provided to enable adjust volume of air as required.

3.2

Fire and Smoke Dampers with Fusible Link Fire and Smoke Dampers (FSD) shall be installed in supply air duct when they pass through AHU room walls as shown in the drawings and as per specfications.The Fire Dampers shall be operated with atleast 90 minutes fire rating as per UL 555S - Class II for fire and smoke management rated for 90 min. & tested at CBRI Roorkee, India.

RABILL NO-1

Installation

Indegenious Supply

QTY

UNIT

5 50 5

RMT RMT RMT

236 236 278

1180 11800 1390

95 95 95

475 4,750 475

2

Sq.M.

7285

14570

950

1,900

4

Nos.

12920

51680

570

Installation

48 5

11328 1390

100% 100%

48 5

4560 475

0

2186

100%

0

285

4

51680

100%

4

2280

2,280

Fusible Link should be rated for 72oC. Each FSD shall be of multi leaf type, low leakage and shall be tested in the factory and will be certified by the manufacturer in form of the test certificate. Each FSD shall be supplied with matching extended sleeve (factory supply) and set of retaining angles for installation on wall / slab as indicated on drawings. [up to max size of 1800 mm x 550 mm - This duct size is given as guideline for estimate, actual duct sizes in the approved drawings shall prevail]. Fire Dampers shall be provided with access doors in ducts / false ceiling.

3.3

Fire & Smoke Dampers with same specifications as above item 3.2 but suitable for motorised operation. Motorised Dampers (To be installed in Supply Air Duct)

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 2

RO

SQ.M.

11764

950

Page 11 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

PART-2 Indegenious Supply SR. NO. DESCRIPTION OF WORKS Motorised Actutator for item C-3.3 3.4 The Actuator shall be direct coupled spring return type and motorised. The Actuator shall be in line with the Technical Specifications and shall be maintenance free direct coupled spring return type suitable to work on 24 V electric supply. The torque rating of the actuator shall exceed at least by 15% over torque required to open / close the damper. Shall have manual over ride facility.The selection of actuator size shall be the responsibility of the manufacturer. Power on indicating lamps with 230 V / 24 V transformer,damper close & open indication, reset push button, push button for manual running of actuator for periodic inspection, auxiliary contacts 24V & 230 V, contact points to receive signal from smoke detector / fire alarm panel etc. should be provided.

3.5

Supply, Installation, Testing and commissioning of Fresh Air Assembly comprises of Cowl, birdscreen, VCD etc. complete as required

4.0 4.1

GRILLES Supply / Return Air L-bar Continous Grill with extruded aluminimum aerofoil construction with end flanges as required. 6" wide Cont. Straight Grill 6" wide Cont. Curved Grill 18" x 8" Door Transfer grill 24" x 8" Door Transfer grill 6" dia Disc Valve 9" dia Disc Valve Assorted Size

4.1.1 4.1.2 4.1.3 4.1.4 4.1.5 4.1.6 4.1.7

QTY RO

UNIT No.

2

nos

2 RO 4 RO RO RO 1

RMT RMT Sets Sets Nos. Nos. Sq.m.

711 852 846 1185 675 987 4601

1422

23526

RABILL NO-1

Installation

Indegenious Supply

950

Already provided by Developer in AHU /

190

2

1422

100%

2

190

380

4

3384

100%

4

380

1

2787

100%

1

608

26

58292

100%

26

4940

4601

95 95 95 95 95 95 950

4.2

Box type dampers in Aluminum construction duly powder coated (black matt finish)

1

sq.m.

4354

4354

950

950

5.0

Air Volume Regulator - Aldes Equi. Make in 3" / 4"dia as required for fixed flow range with regulation.

38

Nos.

2242

85196

190

7,220

6.0 6.1

Square Diffusers: Supply Air Diffuser for Modular FC The 4-way square supply air terminal should be in Al powder coated construction with easily removable central core & 4-way uniform air distribution complete Volume control damper to be of opposed blade, nylon geared with aerofoil blades & black matt powder coated. Factory Installed G.I plenum black painted from inside shall be mounted with a circular neck to accept the insulated flexible duct from side. (Out to Out Size of 24"x24" with required neck size as per approved layouts) & as per approved sample.

RO

No.

2373

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 2

Installation

3384

950

190

Page 12 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

PART-2 Indegenious Supply SR. NO. DESCRIPTION OF WORKS Supply Air Diffuser for Gypsum FC 6.2 The 4-way square supply air terminal should be in Al powder coated construction with easily removable central core & 4-way uniform air distribution. Volume control damper to be of opposed blade, nylon geared with aerofoil blades & black matt powder coated. Factory Installed G.I plenum black painted from inside shall be mounted above the opposed blade damper & with a circular neck to accept the insulated flexible duct from side. (Maximum Out to Out Size 24"x24" with required neck size as per approved layouts) & as per approved sample.

QTY RO

UNIT No.

Return Air Diffuser The return air terminal should be in Al powder coated construction with easily removable central core & 4-way uniform air distribution. Diffuser Size: 24" x 24" 21" x 21" 18" x 18" 15" x 15"

RO

Nos.

6.3

6.3.1 6.3.2 6.3.3 6.3.4

D]

INSULATION

1.0

ACOUSTIC INSULATION OF FALSE CEILING Supply, fabrication and installation of Acoustic insulation on walls and ceiling of AHU rooms as specified and shown on the drawing complete with: 10 mm thick acoustic insulation with Nitrile rubber Insulation / Thermal conductivity 0.045 W/m deg.K / density 140~180 kg/m3, with manufacturer recommended adhesive bonding.

2.0

THERMAL INSULATION Supply, fabrication & Installation of thermal insulation on GI ducts complete with Closed Cell foam with minimum density of 40 Kg/m3 with minimum R Value 4.1/inch & thermal conductivity -0.035 w/mok confirming to Class 'O' & the inner side stuck to the outer facia of the GI ducts with recommended / Proprietory Synthetic adhesive bonding (SR998 or equivalent) & installed as per manufacturers recommendation. The insulation joints shall be sealed with 3" wide Black Tape.

2.1 2.2

9 mm thick Insulation 13 mm thick Insulation

3.0

ACOUSTIC INSULATION Supply, fabrication and installation of acoustic lining of supply and return air ducts as specified and shown on the drawing complete with: a) 48 kg/cum Rigid Board Fibreglass b) CPRX Cold compound bonding. c) RP tissue paper c) 26 G Perforated aluminium cladding 12.5 mm rigid board acoustic lining 10 mm thick acoustic insulation with Closed Cell Foam Armasound / Kfonic / Thermal conductivity 0.045 W/m deg.K / density 140~180 kg/m3, with manufacturer recommended adhesive 520 bonding.

3.1 3.2

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 2

Installation

2315

Indegenious Supply

Installation

190

695,737

TOTAL FOR 'C' - AIR DISRIBUTION

RABILL NO-1

136,610

BY INTERIOR AGENCY AS REQUIRED

RO

sq.m.

998

600 RO

sq.m. sq.m.

293 396

RO 100

sq.m. sq.m.

433 998

171

175800

99800

171 171

228 171

102,600

370

108410

100%

370

63270

81

80439

100%

81

13782.6

17,100

Page 13 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

PART-2 Indegenious Supply 4.0 INSULATION OF WORKS SR. NO. UNDERDECKDESCRIPTION Supply, fabrication and laying of under deck thermal insulation of approved make as specified and shown on the drawing complete with 25mm Closed Cell Foam Insulation - 40 kg/cu.m density stuck to the underside of the exposed slab with recommended /proprietory synthetic adhesive bonding and held in place with GI wire 16 SWG lacing and GI washers at approved distance.

QTY RO

UNIT Sq.M.

E]

VENTILATION AND EXHAUST

1.0

EXHAUST AIR FANS Inline Ducted Fans (To be installed in Existing Toilet Extract Ducts with suitable duct modifications). Pantry fans to be hooked up to Developer's duct. Fans shall be of Low noise. Selection to be approved by Consultant. Fans to be inserted in existing ducting provided by Developer with suitable mounting arrangement and with back draft damper)

1.1 1.2

Inline Ducted Circular / Rectangular fans shall be direct driven type with all accessories etc.complete as per specifications & drawings shall be included. Quoted cost shall include control & starter panel, OLP, SPP, ON/OFF push buttons with ON indications, 2nos. non polarised NO-NC contacts. Panel shall be suitable for outdoor duty application. Cabling: Power cabling of copper armoured cable from control panel to motor with double compression gland. Power & control Cabling and earthing limited to 10 RMT max. Control cabling for hook up to BMS is not included here. (Installation of fans shall mean unloading, liftingshifting, positioning, levelling & installation in place) EF-1000 cfm / 12 mm ESP EF-500 cfm / 12 mm ESP low noise

RO 3

Nos. Nos.

Rs.

25013 10871

Indegenious Supply

Installation

380

275,600

TOTAL FOR 'E' - VENTILATION & EXHAUST

GRAND TOTAL of 'B' + 'C' + 'D' +'E'

Installation

769

TOTAL FOR 'D' - INSULATION

RABILL NO-1

119,700

1,900 1,900

32613

5,700

32,613

5,700

3,093,239

1,234,918

[email protected]% on supply value

1

10871

100%

2210330.56

NOTE1

1900

995,925

276291.32

123096.3053

service [email protected]% on installation value

Grand Total

1

3,605,643

Rates shall be all inclusive

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 2

Page 14 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

% OF CLAMING NOW

100%

100% 100% 100%

100% 100% 100%

100% 100% 100% 100% NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 2

Page 15 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

100%

100%

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 2

Page 16 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

100%

100%

100%

100%

100% 100% 100%

100%

100% NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 2

Page 17 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

100%

100% 100% 100%

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 2

Page 18 of 24

R C Architecture Pvt. Ltd

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 2

N M Deodhar Consulting Engineers HVAC CONSULTANT

Page 19 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

100% 100%

100%

100%

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 2

Page 20 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

100% 100%

100%

100%

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 2

Page 21 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

100%

100%

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 2

Page 22 of 24

N M Deodhar Consulting Engineers HVAC CONSULTANT

R C Architecture Pvt. Ltd

100%

NVIDIA Graphics Pvt. Ltd. Low Side HVAC Works Tender - BOQ - Part 2

Page 23 of 24

MMY-MAP1204T8 MMY-MAP1604T8 MMY-MAP1004T8 MMU-AP0152H MMU-AP0182H MMU-AP0272H MMU-AP0362H MMU-AP0074MH MMU-AP0094MH MMU-AP0124MH MMD-AP0724HFE RBC-AX32U(W)-E TCB-SC642TLE2 RBC-U31PG(W)-E RBC-UM11PG(W)-E TCB-IFMB640TLE RBC-AMT32E

2276021 404506 254000 128339 559322 438828 50379 165725 83108 175041 663390 158738 31870 135693 84579 34322 2329 5646190

12 HP 16HP 10HP 1.3TR- 4 way cassette 1.6TR- 4 way cassette 2.4TR- 4 way cassette 3.2TR- 4 way cassette 0.6TR Compact cassette 0.8TR Compact cassette 1.0TR Compact cassette 6.4 TR TFA Cordless remote CRC Panel for Standard Cassete Panel for Compact Cassete Modbus Corded remote

284503

2560524

373862

373862

42780

128339

43025

559322

43883

438828

50379

50379

41431

165725

41554

83108

43760

175041

165848

663390

4290

158738

31870

31870

5026

135693

8458

84579

34322

34322

582

2329 5646048 142