Header information Nominal Size Outside diameter of header pipe Material spec Thickness Allowable stress for header material from 31.3 Coeff from table 304.1 ( Pg. 20 - ANSI 31.3) Quality factor from 31.3 (E)
Branch information Nominal Size Outside diameter of branch pipe Material spec Thickness Branch inclination Allowable stress for branch material from 31.3 Co-eff. from table 304.1 Quality factor from 31.3 (E) Mill tolerance Min. thickness of main header (Th) Min. thickness of branch header (Tb) Pressure design thickness of main header (th) Pressure design thickness of branch header (tb)
Height of reinforcement zone outside run pipe (L4)
0.437
OR
Hence L4 (whichever is less)
0.437 inches
Effective length removed from pipe at branch (d1) / Half width reinforcement zone (d2) ( Whichever is greater)
507.65
OR
Hence d2/d1
507.65 inches
tc (whichever is less) Hence tc
0.17 OR 0.17 inches
Minimum leg dimension of fillet weld
0.23 inches
Reinforcement area required (A1)
4869.01 Sq. Inch
Reinforcement area available in run pipe (A2)
-4711.11 Sq. Inch
Reinforcement area available in run pipe (A3)
-4.50 Sq. Inch
Area of fillet welds(A4) Available reinforcement area (A5) RESULT REINFORCEMENT IS REQUIRED Incase additional reinforcement is required:
0.06 Sq. Inch -4715.55 Sq. Inch
0.778 inches
254.31 inches
0.25
inches
Thickness of RF pad (Tr) - assume Std. Thk.
0.000 inches
Diameter of RF pad (assume )
0.000 inches
Allowable stress for RF pad from ANSI 31.3
### PSI
Area available in RF pad (A6)
0.00 Sq. Inch
tc - For RF pad
0.00 inches
Minimum leg dimension of fillet weld
0.00 inches
Area available in fillet welds (A7) Available area (A8) RESULT REINFORCEMENT IS INSUFFICIENT
0.000 Sq. Inch -4715.55 Sq. Inch
DATE : 22/05/2001
SHEET No:
CALC. BY: YSR CHECKED BY : PLANT / UNIT No. : RPL
APPROVED BY: CALC No. :
SPEC.: EC32EA LINE SIZE : Branch Reinforcement Calculation (Only highlighted data to be filled) SPEC Branch dia/Header dia ratio (d/D) Design conditions As per LDT Design Temperature
Design Pressure
corrosion allowance (C) Header information Nominal Size Outside diameter of header pipe Material spec Thickness Allowable stress for header material from 31.3 Coeff from table 304.1 ( Pg. 20 - ANSI 31.3) Quality factor from 31.3 (E) Branch information Nominal Size Outside diameter of branch pipe Material spec Thickness Branch inclination Allowable stress for branch material from 31.3 Co-eff. from table 304.1 Quality factor from 31.3 (E) Mill tolerance Min. thickness of main header (Th) Min. thickness of branch header (Tb) Pressure design thickness of main header (th)
Hot Tap Cal.ref no. Dated: EC32EA 0.56 427.00 degrees 800.60 Fahrenheit 28.00 Kg/sqcm2 398.16 PSI 0.06 inches
Height of reinforcement zone outside run pipe (L4)
1.414
OR
Hence L4 (whichever is less)
1.414 inches
Effective length removed from pipe at branch (d1) /Half width reinforcement zone (d2) ( Whichever is greater)
19.47
Hence d2/d1 tc (whichever is less)
19.47 inches 0.26 OR
OR
Hence tc Minimum leg dimension of fillet weld
0.25 inches 0.35 inches
Reinforcement area required (A1)
2.28 Sq. Inch
Reinforcement area available in run pipe (A2)
9.28 Sq. Inch
Reinforcement area available in run pipe (A3)
0.66 Sq. Inch
Area of fillet welds(A4)
0.13 Sq. Inch
Available reinforcement area (A5)
10.06 Sq. Inch
RESULT NO ADDITIONAL REINFORCEMENT IS REQD. Incase additional reinforcement is required: Thickness of RF pad (Tr) - assume Std. Thk. Diameter of RF pad (assume )
0.750 inches 30.000 inches
Allowable stress for RF pad from ANSI 31.3
17500.00 PSI
Area available in RF pad (A6)
7.50 Sq. Inch
tc - For RF pad Minimum leg dimension of fillet weld
0.38 inches 0.53 inches
Area available in fillet welds (A7)
0.281 Sq. Inch
Available area (A8)
17.84 Sq. Inch
RESULT REINFORCEMENT WITH ASSUMED RF PAD SIZE IS O.K