968XTP Maximum Security Switch - Installation Instructions 968XTP
Z (inward
Axis
swinging)
BALANCED MAGNETIC HIGH SECURITY SWITCH
X
Y (outward
swinging)
Minimum Make / Approach Distance
Maximum Break / Removal Distance
inches / mm
inches / mm
0.17 / 4.3 0.53 / 13.5 0.23 / 5.7
0.42 / 10.6 0.72 / 18.2 0.54 / 13.7
X Y Z
Inswinging Door Instructions Honeywell’s 968XTP Maxiumum Security Magnetic Switch is intended to monitor the open or closed position of doors, windows, machinery safety barriers or other movable assemblies in critical environments where an attempt to defeat the switch is a concern. The switch includes numerous design features that make it highly defeat-resistant, reduce false alarms and provide for easy and accurate installation. The performance of the 968XTP is unaffected by the type of surface on which it is mounted (steel or wood). The 968XTP features an attack-resistant steel jacketed cable.
Step 1 - Install the Tamper Plate
Step 2 - Install the Switch
• Line up the edge of the tamper plate with the edge of the door frame, 1/2” (12.7 mm) [minimum] from the side edge. The arrows on the tamper plate must be pointing toward the door. • Mark the six hole centers for drilling pilot mounting holes. • Drill two #6 (3.5 mm) pilot holes where shown. • Drill four #8 (4.1 mm) pilot holes where shown. • Mount the tamper plate in place using two #6 (3.5 mm) screws [provided].
• Install the switch assembly to the tamper plate with four #8 (4.1 mm) screws [provided]. Make sure that the arrow is pointing toward the door.
#6 (3.5 mm) #8 Screw (4.1 mm) Screw
#8 (4.1 mm) Screw DOO
Open
DOO
R
R
1/2” (12.7 mm)
Frame
Door
Step 3 - Install the Magnet • • • • • • • •
Align the edges of the magnet assembly to the edges of the switch assembly. Position the magnet assembly so the arrow faces the arrow of the switch assembly. Important: Gap distance must be 7/16 ±1/16” (11.1 mm ±1.6 mm). Mark the mounting holes, drill pilot holes for #8 (4.1 mm) screws [provided]. Use the magnet spacer plates to align the front surface of the magnet to match the front surface of the switch. Verify that the arrow on the magnet assembly is facing the arrow on the switch assembly. Install the necessary spacer plates and magnet assembly on the door with two #8 (4.1 mm) screws [provided]. See Supplemental Information for wiring instructions. Switch Assembly
Align edges
Align edges 7/16” (11.1 mm) Gap
SEPA WIT RATE HM FO AGN R USE ET O NLY
TAM PE SCR R EW
Magnet Assembly
Adjust height with spacers -1-
PRELIMINARY DRAFT 11/4/09
968XTP Maximum Security Switch - Installation Instructions Outswinging Door Instructions General Guidelines
Step 3 - Install the Switch
• Mount the magnet assembly to the door, mount the switch assembly to the frame.
• Verify that the arrow on the switch assembly is facing the arrow on the magnet assembly. • Mount the switch assembly to the tamper plate using four #8 (4.1 mm) screws [provided]. • See Supplemental Information for wiring instructions.
Frame
Align Edges Area to be protected
3/16” 4.8 mm
Door 7/16” 11.1 mm
OPEN
Step 1 - Install the Magnet • Place the magnet 2” (51 mm) [minimum] from the side of the door frame and 3/16” 3/16” (4.8 mm) (4.8 mm) from the top. • Mark the two mounting holes and drill pilot holes for #8 Door (4.1 mm) screws 2” (51 mm) [provided]. Frame Minimum • Mount the magnet on the door using two #8 (4.1 mm) screws with the Honeywell label surface facing down and the arrow pointing away from the door.
Step 2 - Install the Tamper Plate • Line up the edge of the tamper plate to the edge of the magnet. Make sure the #8 arrows on the (4.1 mm) #6 tamper plate Screw (3.5 mm) 7/16” are pointing #8 Screw (11.1 mm) toward the (4.1 mm) door. Screw • Measure the Align edges OR DO gap distance 7/16” ±1/16” (11.1 mm ±1.6 mm). • Mark the mounting holes Door and drill pilot Frame holes for two #6 (3.5mm) and four #8 (4.1 mm) screws [provided]. • Mount the tamper plate in place using two #6 (3.5 mm) screws. For the latest U.S. warranty information, please go to: www.honeywell.com/security/hsc/resources/wa or Please contact your local authorized Honeywell representative for product warranty information. ! 2006 Honeywell International Inc. Honeywell is a registered trademark of Honeywell International Inc. All other trademarks are the properties of their respective owners. All rights reserved. Assembled in Mexico.
OR
DO
Door
Frame
Supplemental Information Wiring • The normal condition of the 968XTP is when it is reporting secure, energized by the magnet. • The two white tamper wires will be closed when the tamper switch is in secure condition. • The tamper contacts should be connected to a 24 hour circuit to trigger an alarm any time the switch module is tampered with. • Maximum contact ratings depend on the voltage put through the switch. They are 250 mA at 12 V or less and 125 mA at 24 V. The tamper circuit can handle a maximum of 1 Amp. Black Green Red White White
Common Normally Closed (NC) Normally Open (NO) Tamper NC Tamper NC
Green Red Black White White
NC NO COM Tamper NC Tamper NC
Notes • To minimize tamper potential, the 968XTP should be installed inside the perimeter being protected. • The switch assembly / magnet combination is designed to have a nominal gap of 0.45” (11.4 mm). The system will go into alarm condition if the gap is approximately 0.63” (16.0 mm) and greater, or approximately 0.27” (6.9 mm) or less. To account for system tolerances, a 7/16” ±1/16” (11.1 mm ±1.6 mm) gap has been specified in these instructions. The minimum make gap is 0.53” (13.5 mm). • Approvals/listings: cULus listed EN 50131-1:2006 and EN 50131-2-6:2008 Security Grade 3 Environmental Class II; Certified by VdS. Suitable for connection to an EN 60950 Class II Limited Power Source in European Installations. For any additional information, please refer to our Website, www.honeywell.com/security/emea/hscdownload or contact: Honeywell Security Group Quality Assurance Dept. Newhouse Industrial Estate Tel: +44(0)1698 738200 Motherwell Email: