Download HAZOP Case Studies for Workshop Session...
Description
HAZOP Case Studies – Example 1 Cooling Coils Monomer Feed
Refer to reactor system shown.
Cooling Water to Sewer
The reaction is exothermic. A cooling system is provided to remove the excess energy of reaction. In the event of cooling function is lost, the temperature of reactor would increase. This would lead to an increase in reaction rate leading to additional energy release.
Cooling Water In
T C
Thermocouple
The result could be a runaway reaction with pressures exceeding the bursting pressure of the reactor. The temperature within the reactor is measured and is used to control the cooling water flow rate by a valve. Perform HAZOP Study
1
Process Risk Seminar 22nd Dec 2009 Workshop Session
Preliminary HAZOP on Reactor – Example – fill in the gaps Guide Word
Deviation
Causes
Consequences
Action
NO
No cooling
REVERSE
Reverse cooling flow
MORE
More cooling flow
Instruct operators on procedures
AS WELL AS
Reactor product in coils
Check maintenance procedures and schedules
OTHER THAN
Another material besides cooling water
Temperature increase in reactor Failure of water source resulting in backward flow
Water source contaminated
Process Risk Seminar 22nd Dec 2009 Workshop Session
2
Case Study – Shell & Tube Heat Exchanger Using relevant guide works, perform HAZOP study on shell & tube heat exchanger
Process fluid
Cooling water
3
Process Risk Seminar 22nd Dec 2009 Workshop Session
HAZOP Study Form HAZOP STUDY REPORT FORM TITLE :
Sheet 1 of LINE 1 : CAUSES
CONSEQUENCES
DEVIATION
4
Process Risk Seminar 22nd Dec 2009 Workshop Session
Thank you for interesting in our services. We are a non-profit group that run this website to share documents. We need your help to maintenance this website.