M-Group Stainless Steel End Suction Pumps
DD
Bombas de Succión Final de Acero Inoxidable Grupo-M
L 3
⁄8" NPT
X
D
HG
KEYWAY 3⁄16 X 3⁄8 3
⁄4 NPT HF
L
Y
51⁄8
DD
31⁄2
31⁄2
L
A Full Range of Product Features, Una Gama Total de Características del Producto Superior Materials of Construction: AISI Type 304SS pump parts for reduced corrosion and improved strength and ductility. Frame Mounted Design: Flexibility of installation and driver arrangements. Back Pull-Out Design: Simplifies maintenance when used with spacer type coupling.
Drive Motors: Standard NEMA design T-frame or JM motors in single or three phase. Suction and Discharge Flanges: Mate with ANSI class 150 flanges. Close-Coupled Design: Compact design saves space and simplifies maintenance.
Cast Iron Power Frame: Rigidly supported, grease lubricated ball bearing assembly.
Materiales Superiores de Construcción: Partes de la bomba de acero inoxidable AISI Tipo 304 para corrosión reducida y fuerza y ductilidad mejoradas.
Motores de Accionamiento: Motores de armazón-T NEMA estándar unifásicos o trifásicos. Bridas de Succión y Descarga: Acoplan con bridas ANSI clase 150.
Diseño de Armazón Montado: Flexibilidad de instalación y colocación del motor.
Diseño de Acople Cerrado: El diseño compacto ahorra espacio y simplifica el mantenimiento.
Diseño de Extracción Trasera: Simplifica el mantenimiento cuando se usa con el acople tipo espaciador. Armazón del Motor de Hierro Fundido: Rígidamente soportado, con ensamblaje de balineras de bolas lubricadas con grasa .
Mechanical Seal: Standard John Crane Type 21 mechanical seal.
Sello Mecánico: Sello mecánico estándar John Crane Tipo 21.
Performance Coverage, 3500 and 1750 RPM Alcance de Funcionamiento, 3500 y 1750 RPM
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
FEET (PIES) 1000 800 3500 RPM
600 500 400
24ST
300
25ST
26ST
27ST 28ST
21ST 200
22ST
23ST
150 100 80
24ST
60 50 40
25ST
26ST 27ST
28ST
21ST
30
23ST
1750 RPM
20
22ST
15 10 20
30
40
50 60 80 100 150 200 300 400 500 600 GALLONS PER MINUTE (GALONES POR MINUTO) Q
800 1000
1500
2
SST M-Group Numbering System Sistema de Numeración del Grupo-M SST Example Product Code, Ejemplo Código del Producto 21 ST 1 H 1 A 0 Mechanical Seals and O-Ring 0 = Pre-engineered standard For optional mechanical seal modify catalog order no. with seal code listed below. Sello Mecánico y Anillo ‘0’ 0 = Estándar aprobado Para sello mecánico opcional modificar el número de orden del catálogo con el código del sello anotado abajo. John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Seal Code, Código del Sello
Part No., Pieza Número Stationary, Estacionario
Elastomers, Elastómeros
0
Ceramic
BUNA
2
Ni-Resist
EPR
Rotary, Rotativo
Carbon
3 4
Ceramic
316 SS, 316 Acero inoxidable
Viton
Tung-Carb
Metal Parts, Partes Metálicas
180-210 Frames, Armazones
250-360 Frames, Armazones
10K13
10K16
10K19
10K20
10K25
10K26
10K27
10K45
Casing O-Ring, Carcasa Anillo ‘0’
BUNA Viton
Impeller Option Code For optional impeller diameters modify catalog order no. with impeller code listed below. Select optional impeller diameter from pump performance curve. Código del Impulsor Opcional Para diámetros del impulsor opcional modificar el número de orden del catálogo con el código del impulsor anotado abajo. Seleccionar el diámetro del impulsor opcional de la curva de funcionamiento de la bomba. Impeller Code, Código del impulsor A B C D E F G H J
Pump Size, Tamaño de la Bomba 21ST 2 x 21⁄2 – 8 Diameter 85⁄8 87⁄16 81⁄4 77⁄8 71⁄2 71⁄16 611⁄16 61⁄2 N/A
22ST 21⁄2 x 3 – 8 Diameter 91⁄16 83⁄4 81⁄2 81⁄4 77⁄8 71⁄2 71⁄8 611⁄16 61⁄2
23ST 3x4–8 Diameter 91⁄16 811⁄16 87⁄16 81⁄16 711⁄16 71⁄2 71⁄8 67⁄8 61⁄2
24ST 11⁄4 x 2 – 10 Diameter 101⁄16 913⁄16 91⁄4 87⁄8 85⁄8 81⁄4 77⁄8 73⁄4 N/A
25ST 11⁄2 x 21⁄2 – 10 Diameter 101⁄16 913⁄16 95⁄8 97⁄16 87⁄8 87⁄16 81⁄16 73⁄4 N/A
26ST 2 x 21⁄2 – 10 Diameter 101⁄16 913⁄16 97⁄16 91⁄16 87⁄8 85⁄8 87⁄16 81⁄16 N/A
27ST 21⁄2 x 3 – 10 Diameter 103⁄8 915⁄16 99⁄16 91⁄4 83⁄4 N/A N/A N/A N/A
Driver, Conductor 1 = 1 PH, ODP 3 = 575 V, ODP 2 = 3 PH, ODP 4 = 1 PH, TEFC
5 = 3 PH, TEFC 6 = 575 V, TEFC
7 = 3 PH, XP 8 = 575 V, XP
9 = 3 PH, TEFC Premium Eff.
HP Rating, HP Potencia E = 1 HP H = 3 HP F = 11⁄2 HP J = 5 HP G = 2 HP K = 71⁄2 HP
L = 10 HP M = 15 HP N = 20 HP
P = 25 HP Q = 30 HP R = 40 HP
S = 50 HP T = 60 HP U = 75 HP
Driver: Hertz/Pole/RPM, Conductor: Hercios/Polo/RPM 1 = 60 Hz, 2 pole, 3500 RPM 3 = 60 Hz, 6 pole, 1150 RPM 2 = 60 Hz, 4 pole, 1750 RPM 4 = 50 Hz, 2 pole, 2900 RPM Material ST = Stainless steel, Acero inoxidable Pump Size, Tamaño de la Bomba 21 = 2 x 21⁄2 – 8 24 = 11⁄4 x 2 – 10 22 = 21⁄2 x 3 – 8 25 = 11⁄2 x 21⁄2 – 10 23 = 3 x 4 – 8 26 = 2 x 21⁄2 – 10
27 = 21⁄2 x 3 – 10 28 = 3 x 4 – 10
V = 100 HP
5 = 50 Hz, 4 pole, 1450 RPM
28ST 3 x 4 – 10 Diameter 105⁄8 101⁄4 913⁄16 97⁄16 91⁄16 811⁄16 N/A N/A N/A
For frame mounted pumps substitute the letters “FRM”.
Para bombas con armazón montado sustituya las letras “FRM”.
NOTE: Not all combinations of motor, impeller and seal options are available for every pump model. Please check with G&L on non-cataloged numbers.
NOTA: No todas las combinaciones de las opciones de motor, impulsor y sello están disponibles para cada modelo de bombas. Por favor verifique con G&L en los números no catalogados.
3
Performance Curves – 60 Hz, 3500 RPM Curvas de Funcionamiento – 60 Hz, 3500 RPM
METERS METROS
FEET PIES
Model SST – 21ST / Size (Tamaño) 2 x 21⁄2-8 RPM 3500 Curve (Curva) CN0256R00 IMP. DWG. No. 452303321 (M) NPSHR – FEET (PIES) 6' 50 60
10' 65
5 350 A 8 ⁄8" DIA.
67
B 87⁄16"
15'
100
20' C 81⁄4"
90 80
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
69 70
25'
300
69 D 77⁄8"
67 65
250 E 7 ⁄2" 1
70 60
60 EFF%
F 71⁄16"
Optional Impeller, Impulsor Opcional Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia A B C D E F G H
85⁄8" 87⁄16 81⁄4 77⁄8 71⁄2 71⁄16 611⁄16 61⁄2
50 50 40 40 30 25 25 20
NOTE: Pump will pass a sphere to 9⁄16" diameter.
11 200 G 6 ⁄16"
50
H 61⁄2"
NOTA: La bomba pasará una esfera a 9⁄16" diámetro.
HP
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
110
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
40
50
H P
150
20
40 100 0
100
0
20
200
300
30 P
25
400
60
40
H
80
HP
HP
500 100
U.S. GPM
600 120
m3⁄hr
140
CAPACITY (CAPACIDAD) Q
METERS METROS
Model SST – 26ST / Size (Tamaño) 2 x 21⁄2-10 RPM 3500 Curve (Curva) CN0248R03 IMP. DWG. No. 452303331 (M)
FEET PIES
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
NPSHR – FEET (PIES)
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
6' 10' 55 1 500 A 10 ⁄16" DIA.
60
15' 65
67
B 9 ⁄16" 13
140
20' 69
72
C 97⁄16"
120
400 D 9 ⁄16"
100
E 87⁄8" F 85⁄8" G 87⁄16"
25' 30'
70 71
71
70
69 EFF%
1
67
75
300 H 81⁄16" 60
80 60
30
200
50 HP
40
HP
Optional Impeller, Impulsor Opcional Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia A B C D E F G H
75 75 60 60 50 50 40 40
101⁄16" 913⁄16 97⁄16 91⁄16 87⁄8 85⁄8 87⁄16 81⁄16
NOTE: Pump will pass a sphere to 1⁄2" diameter.
HP
NOTA: La bomba pasará una esfera a 1⁄2" diámetro.
HP
HP
40 100 20
0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0 0
100 20
200 40
300 60
400 80
500 100
600 120
140
700
U.S. GPM
160
m3⁄hr
CAPACITY (CAPACIDAD) Q
4
Performance Curves – 60 Hz, 3500 RPM Curvas de Funcionamiento – 60 Hz, 3500 RPM
METERS METROS
Model SST – 25ST / Size (Tamaño) 11/2 x 21⁄2-10 RPM 3500 Curve (Curva) CN0244R03 IMP. DWG. No. 452303231 (M)
FEET PIES
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
NPSHR – FEET (PIES) 6'
7' 8'
A 10 ⁄16" DIA. 1
500
45
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
50
55
60
10'
64
65
66 67
D 97⁄16"
120
400
65 EFF%
50
E 87⁄8" F 87⁄16"
100
64 4 0
G 81⁄16" H 73⁄4"
300
20'
80 60
66
30 15
200
20
HP
25
HP
HP
40 30 25 25 20 20 15 15
101⁄16" 913⁄16 91⁄4 87⁄8 85⁄8 81⁄4 77⁄8 73⁄4
NOTE: Pump will pass a sphere to 5⁄32" diameter.
HP
HP
HP
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia A B C D E F G H
15' 20'
62
C 95⁄8"
140
12'
Optional Impeller, Impulsor Opcional
NOTA: La bomba pasará una esfera a 5⁄32" diámetro.
40 100 20
0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
50
0
10
100
150
20
200
30
40
250 50
300 60
350
400
m3⁄hr
80
70
U.S. GPM
CAPACITY (CAPACIDAD) Q
METERS METROS
Model SST – 25ST / Size (Tamaño) 11/2 x 21⁄2-10 RPM 3500 Curve (Curva) CN0244R03 IMP. DWG. No. 452303231 (M)
FEET PIES
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
NPSHR – FEET (PIES) 6'
7' 8'
A 101⁄16" DIA.
500
45
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
50
55
60
10'
64
5
65
66 67
D 97⁄16"
120
400
66
65 EFF%
50
E 87⁄8" F 8 ⁄16"
HP
7
100
64 4 0
G 81⁄16" H 73⁄4"
300
20'
80 60
30 15
200
20
HP
25 HP
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia A C D E F G H
15' 20'
62
C 9 ⁄8"
140
12'
Optional Impeller, Impulsor Opcional
HP
50 40 40 30 25 25 20
101⁄16" 95⁄8 97⁄16 87⁄8 87⁄16 81⁄16 73⁄4
NOTE: Pump will pass a sphere to 5⁄16" diameter.
HP
NOTA: La bomba pasará una esfera a 5⁄16" diámetro.
HP
40 100 20
0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0 0
50 10
100 20
150 30
200 40
250 50
300 60
70
350 80
400
U.S. GPM m3⁄hr
CAPACITY (CAPACIDAD) Q
5
Performance Curves – 60 Hz, 3500 RPM Curvas de Funcionamiento – 60 Hz, 3500 RPM
METERS METROS
Model SST – 22ST / Size (Tamaño) 21⁄2 x 3-8 RPM 3500 Curve (Curva) CN0354R00 IMP. DWG. No. 119-74
FEET PIES
40% EFF
350
90
300 275
80 70 60
A 91⁄16" DIA.
65
3 325 B 8 ⁄4"
10' 12'
C 81⁄2"
68
D 81⁄4"
70
15' 20' 25' 68 30'
65
7 250 E 7 ⁄8"
60 71
1 225 F 7 ⁄2"
200 G 71⁄8" 11 175 H 6 ⁄16"
60
J 61⁄2"
50 150
60 50 50 40 40 30 25 20
91⁄16" 83⁄4 81⁄2 81⁄4 77⁄8 71⁄2 71⁄8 611⁄16
J
20
61⁄2
NOTA: La bomba pasará una esfera a 19⁄32" diámetro.
P
100 75 50
A B C D E F G H
25
100
0
20
200
300
400
60
40
500
80
H
H P 20 HP
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
30
HP
20
50 H
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia
40
30
15
125
Optional Impeller, Impulsor Opcional
NOTE: Pump will pass a sphere to 19⁄32" diameter.
P
HP
40
H
50
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
100
(PIES) 7' NPSHR – FEET 8' 50 60
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
100
600 120
P
800
700 160
140
180
U.S. GPM m3⁄hr
CAPACITY (CAPACIDAD) Q
METERS METROS
Model SST – 27ST / Size (Tamaño) 21⁄2 x 3-10 RPM 3525 Curve (Curva) CN0352R00 IMP. DWG. No. 119-74
FEET PIES
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
600 175
7' NPSHR – FEET (PIES)
550
45% EFF
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
150
500
10'
60
12'
65
A 103⁄8" DIA.
450 B 915⁄16" 125
15'
69
20' 30' 70
9 400 C 9 ⁄16"
350 100
69
D 91⁄4"
10
E 83⁄4"
300 75
40
250
25
60
150
100 75 75 60 50
103⁄8" 915⁄16 99⁄16 91⁄4 83⁄4
NOTE: Pump will pass a sphere to 19⁄32" diameter.
P
NOTA: La bomba pasará una esfera a 19⁄32" diámetro.
75 H 65 P
50
HP
HP
100 50
0
0H
HP
200 50
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia A B C D E
8' 55
Optional Impeller, Impulsor Opcional
0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0 0
100 20
200 40
300 60
400 80
500 100
600 120
140
700 160
800 180
U.S. GPM m3⁄hr
CAPACITY (CAPACIDAD) Q
6
Performance Curves – 60 Hz, 3500 RPM Curvas de Funcionamiento – 60 Hz, 3500 RPM
METERS METROS
Model SST – 23ST / Size (Tamaño) 3 x 4-8 RPM 3500 Curve (Curva) CN0363R00 IMP. DWG. No. 119-72
FEET PIES
10' 50% EFF
350
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
100 90 80
A 91⁄16" DIA.
12' NPSHR – FEET (PIES) 60 14' 70
325
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
B 811⁄16"
17'
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
75
300 C 8 ⁄16" 7
20'
77
25'
78
275 D 81⁄16"
77
250 E 711⁄16" 70 60
30'
78
75
1 225 F 7 ⁄2"
G 71⁄8"
200
75
H 67⁄8"
175 50
30 20
125 100
40
75 50
25
0
200
0
40
400
600 120
80
30 HP
800 160
A B C D E F G H
75 75 60 50 50 40 40 30
91⁄16" 811⁄16 87⁄16 81⁄16 711⁄16 71⁄2 71⁄8 67⁄8
J
25
61⁄2
NOTA: La bomba pasará una esfera a 3⁄4" diámetro.
HP
HP
1000 200
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia
NOTE: Pump will pass a sphere to 3⁄4" diameter.
60 70 HP 50 HP
150 40
HP
J 61⁄2"
Optional Impeller, Impulsor Opcional
1200
240
280
1400 320
1600
U.S. GPM m3⁄hr
360
CAPACITY (CAPACIDAD) Q
METERS METROS
Model SST – 28ST / Size (Tamaño) 3 x 4-10 RPM 3525 Curve (Curva) CN0361R00 IMP. DWG. No. 119-72
FEET PIES
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering.
Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
600 175
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
550 150
125
NPSHR – FEET (PIES) 500 8' 10' 45% EFF 55 12' 65 450 70 73 C 913⁄16" DIA.
400
14' 17' 75
D 9 ⁄16" 7
100
20'
76
75
60
H
10
P
200 50
30'
73
75
C D E F
100 100 75 75
913⁄16" 97⁄16 91⁄16 811⁄16
NOTA: La bomba pasará una esfera a 3⁄4" diámetro.
F 811⁄16"
250
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia
NOTE: Pump will pass a sphere to 3⁄4" diameter.
25'
76
350 E 91⁄16" 300
75
Optional Impeller, Impulsor Opcional
0
HP
HP
150 100
25 50 0
0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0 0
200 40
400 80
600 120
800 160
1000 200
240
1200 280
1400 320
1600 360
U.S. GPM m3⁄hr
CAPACITY (CAPACIDAD) Q
7
Performance Curves – 60 Hz, 1750 RPM Curvas de Funcionamiento – 60 Hz, 1750 RPM
FEET PIES
30
100
NPSHR – FEET (PIES) 4' 50
55
A 85⁄8" DIA.
25
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
60
63
B 8 ⁄16"
80
65
6' 66
67
8' 67
D 77⁄8"
10'
66
E 71⁄2"
20
65 15'
63
60
60 G 6 ⁄16" H 61⁄2"
15 40
50 EFF%
NOTA: La bomba pasará una esfera a 9⁄16" diámetro.
HP
⁄ H
10
85⁄8" 87⁄16 77⁄8 71⁄2 611⁄16 61⁄2
1 2
2
71⁄2 71⁄2 5 5 3 3
NOTE: Pump will pass a sphere to 9⁄16" diameter.
55
11
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia A B D E G H
5'
7
Optional Impeller, Impulsor Opcional
7
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
METERS METROS
Model SST – 21ST / Size (Tamaño) 2 x 21⁄2-8 RPM 1750 Curve (Curva) CN0258R00 IMP. DWG. No. 452301621 (S)
P
5 H P
5
0
20
0
3
HP
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
50
0
100
10
150 30
20
200 40
250 50
350
300 60
80
70
U.S. GPM m3⁄hr
CAPACITY (CAPACIDAD) Q
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
METERS METROS
Model SST – 26ST / Size (Tamaño) 2 x 21⁄2-10 RPM 1750 Curve (Curva) CN0250R01 IMP. DWG. No. 452301631 (S)
FEET PIES
NPSHR – FEET (PIES) 5'
40 125
A 101⁄16" DIA.
35 30
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
55
60
B 9 ⁄16"
63
13
8'
67
10'
C 97⁄16"
100
65
D 91⁄16"
25 20 15
63
10
71 ⁄2
50 5
25 0
10 10 71⁄2 71⁄2 5 5
101⁄16" 913⁄16 97⁄16 91⁄16 87⁄16 81⁄16
NOTE: Pump will pass a sphere to 1⁄2" diameter.
60 EFF% 7 75 G 8 ⁄16" H 81⁄16"
10 5
20'
67
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia A B C D G H
6' 65
Optional Impeller, Impulsor Opcional
NOTA: La bomba pasará una esfera a 1⁄2" diámetro.
HP
HP
HP
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0 0
50 10
100 20
150 30
200 40
250 50
300 60
70
350
U.S. GPM
80
m3⁄hr
CAPACITY (CAPACIDAD) Q
8
Performance Curves – 60 Hz, 1750 RPM Curvas de Funcionamiento – 60 Hz, 1750 RPM
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
METERS METROS
Model SST – 24ST / Size (Tamaño) 11⁄4 x 2-10 RPM 1750 Curve (Curva) CN0254R01 IMP. DWG. No. 452301431 (S)
FEET PIES
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
35
NPSHR – FEET (PIES)
40
A 10 ⁄16" DIA. B 913⁄16" 1
30
100
45
4' 48
50
6' 10'
51
20' 50
25
D 8 ⁄8" 7
5H
G 77⁄8"
20
H 7 ⁄4"
15
50
3 2
10 25 5
0
101⁄16" 913⁄16 87⁄8 85⁄8 77⁄8 73⁄4
NOTA: La bomba pasará una esfera a 5⁄32" diámetro.
P
45
3
5 5 3 3 2 2
NOTE: Pump will pass a sphere to 5⁄32" diameter.
48 EFF%
75 E 85⁄8"
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia A B D E G H
125 35
Optional Impeller, Impulsor Opcional
HP
HP
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
20
40
0
60
80
100
140
120
20
10
U.S. GPM m3⁄hr
30
CAPACITY (CAPACIDAD) Q
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
METERS METROS
Model SST – 25ST / Size (Tamaño) 11⁄2 x 21⁄2-10 RPM 1750 Curve (Curva) CN0246R02 IMP. DWG. No. 452301531 (S)
FEET PIES
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
NPSHR – FEET (PIES) 4' A 101⁄16" DIA.
125
40
45
50
52
35
54
7'
56 57
D 97⁄16"
30
100
10' 14'
58 58
25
56 EFF%
71 ⁄2 H
G 81⁄16"
75
H 7 ⁄4"
5
50
3
71⁄2 71⁄2 5 5 3 3
101⁄16" 95⁄8 97⁄16 87⁄8 81⁄16 73⁄4
NOTE: Pump will pass a sphere to 5⁄16" diameter.
P
3
20 15
57
E 87⁄8"
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia A C D E G H
5'
C 95⁄8"
Optional Impeller, Impulsor Opcional
NOTA: La bomba pasará una esfera a 5⁄16" diámetro.
HP
HP
10 25 5
0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0 0
25 5
50 10
75 15
100 20
125 25
150 30
35
175 40
200
U.S. GPM m3⁄hr
CAPACITY (CAPACIDAD) Q
9
Performance Curves – 60 Hz, 1750 RPM Curvas de Funcionamiento – 60 Hz, 1750 RPM
METERS METROS
Model SST – 22ST / Size (Tamaño) 21⁄2 x 3-8 RPM 1725 Curve (Curva) CN0353R00 IMP. DWG. No. 119-75
FEET PIES
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
120 35
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
110 30
40% EFF
5' 50
A C D E G H
NPSHR – FEET (PIES) 6'
55
80 A 91⁄16" DIA.
60
8'
62
C 81⁄2"
70
64
D 81⁄4"
20
10'
60 E 7 ⁄8"
60
15'
55
50
G 7 ⁄8"
91⁄16" 81⁄2 81⁄4 77⁄8 71⁄8 611⁄16
NOTA: La bomba pasará una esfera a 19⁄32" diámetro.
50
1
71⁄2 71⁄2 5 5 3 3
NOTE: Pump will pass a sphere to 19⁄32" diameter.
62
7
15
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia
100 90
25
Optional Impeller, Impulsor Opcional
40 H 611⁄16" 10
2H
30
P
71 ⁄2 H
20 5
5H
10 0
0
3H
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
50
0
10
100
150 30
20
200 40
250 60
70
P
P
350
300
50
P
400
450 U.S. GPM
90
80
m3⁄hr
100
CAPACITY (CAPACIDAD) Q
METERS METROS
Model SST – 27ST / Size (Tamaño) 21⁄2 x 3-10 RPM 1725 Curve (Curva) CN0340R00 IMP. DWG. No. 119-75
FEET PIES
NPSHR – FEET (PIES)
50% EFF
120
55
35
60
110
5'
63
A 103⁄8" DIA.
66 68
30
25
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia
7'
A B C D E
10'
100
68
C 99⁄16"
90
Optional Impeller, Impulsor Opcional
15'
66
D 91⁄4"
20' 63
80
E 83⁄4"
60
15
20
HP
55
60 50
103⁄8" 915⁄16 99⁄16 91⁄4 83⁄4
NOTA: La bomba pasará una esfera a 19⁄32" diámetro.
HP
15
15 10 10 71⁄2 71⁄2
NOTE: Pump will pass a sphere to 19⁄32" diameter.
70
5 10 HP
40
⁄
1 2
7
5
P
10
H
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
B 915⁄16"
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
30 20 10
0
0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0 0
50 10
100 20
150 30
200 40
250 50
300 60
70
350 80
400 90
450 U.S. GPM 100
m3⁄hr
CAPACITY (CAPACIDAD) Q
10
Performance Curves – 60 Hz, 1750 RPM Curvas de Funcionamiento – 60 Hz, 1750 RPM
METERS METROS
Model SST – 23ST / Size (Tamaño) 3 x 4-8 RPM 1725 Curve (Curva) CN0362R00 IMP. DWG. No. 119-73
FEET PIES
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
120 35
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
110 30
Optional Impeller, Impulsor Opcional Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia A C D F G J
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
100 45% EFF 55 1 80 A 9 ⁄16" DIA.
90 25
65
5' NPSHR – FEET (PIES) 68 6' 71
70 C 87⁄16" 20
5
74 73
NOTA: La bomba pasará una esfera a 3⁄4" diámetro.
71 68
G 71⁄8"
65 J 61⁄2"
55
30 3
20
10
7 1⁄
HP
5H
10 0
NOTE: Pump will pass a sphere to 3⁄4" diameter.
15'
E 71⁄2"
50 40
10
10'
D 8 ⁄16"
60 15
8'
73
1
91⁄16" 87⁄16 81⁄16 71⁄2 71⁄8 61⁄2
10 71⁄2 71⁄2 5 5 3
0
0
100 20
0
200 40
300
400 80
60
500 100
600 120
140
2
HP
HP
P
900 U.S. GPM
800
700
180
160
200
m3⁄hr
CAPACITY (CAPACIDAD) Q
FEET PIES
40
130
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
METERS METROS
45% EFF 55
65
120 A 105⁄8" DIA.
A B C D
8'
73
110 B 10 ⁄4"
10'
100 C 913⁄16"
74
7 90 D 9 ⁄16"
20' 70 65
10
60
H
P
20
50
15
40 30 20
105⁄8" 101⁄4 913⁄16 97⁄16
NOTA: La bomba pasará una esfera a 3⁄4" diámetro.
30'
80 70
10
20 15 15 15
NOTE: Pump will pass a sphere to 3⁄4" diameter.
15' 73
20
15
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia
7' NPSHR – FEET (PIES)
1
25
Optional Impeller, Impulsor Opcional
70
35
30
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
Model SST – 28ST / Size (Tamaño) 3 x 4-10 RPM 1725 Curve (Curva) CN0360R00 IMP. DWG. No. 119-72
H
H
P
P
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0 0
100 20
200 40
300 60
400 80
500 100
600 120
140
700 160
800 180
900 U.S. GPM 200
m3⁄hr
CAPACITY (CAPACIDAD) Q
11
Performance Curves – 50 Hz, 2900 RPM Curvas de Funcionamiento – 50 Hz, 2900 RPM
METERS METROS
FEET PIES
275 80
Model SST – 21ST / Size (Tamaño) 2 x 21⁄2-8 RPM 2900 Curve (Curva) CN0365R00 IMP. DWG. No. 452303321 (M) NPSHR – FEET (PIES)
5' 6'
50
250
8'
60
A 8 ⁄8" DIA.
10'
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
5
70
65
B 8 ⁄16"
12'
7
225
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
68
60
200
69 68
D 77⁄8"
20' 65
175 E 71⁄2"
60
50 150
F 71⁄16"
30
G 611⁄16"
40
25
1 125 H 6 ⁄2"
10
30
100
H
20 P 15
H
75 20
H
H
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia A B C D E F G H
15'
C 81⁄4"
Optional Impeller, Impulsor Opcional
H
P
85⁄8" 87⁄16 81⁄4 77⁄8 71⁄2 71⁄16 611⁄16 61⁄2
30 30 25 25 20 15 15 15
NOTE: Pump will pass a sphere to 9⁄16" diameter.
P
NOTA: La bomba pasará una esfera a 9⁄16" diámetro.
P
P
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
50 0
100
0
200
300
40
20
60
400 80
500 100
600 120
140
U.S. GPM 700 m3⁄hr
CAPACITY (CAPACIDAD) Q
METERS METROS
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
125
100
FEET PIES
Model SST – 26ST / Size (Tamaño) 2 x 21⁄2-10 RPM 2900 Curve (Curva) CN0370R00 IMP. DWG. No. 452303331 (M)
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díamet ro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
NPSHR – FEET (PIES)
400
6'
350 A 101⁄16" DIA.
50
60
8'
11'
65
B 913⁄16"
17' 69
20' 25'
70
300 C 97⁄16"
69 67
D 91⁄16"
75
250
65
50
F 8 ⁄8" G 87⁄16" 1 200 H 8 ⁄16" 5
40
50
30
150 20
HP
25
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia A B C D F G H
14'
67
Optional Impeller, Impulsor Opcional
HP
HP
50 40 40 30 30 25 20
101⁄16" 913⁄16 97⁄16 91⁄16 85⁄8 87⁄16 81⁄16
NOTE: Pump will pass a sphere to 1⁄2" diameter.
HP
NOTA: La bomba pasará una esfera a 1⁄2" diámetro.
HP
100 25 50 NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
0 0 0
100 20
200 40
300 60
400 80
500 100
600 120
140
U.S. GPM 700 m3⁄hr
CAPACITY (CAPACIDAD) Q
12
Performance Curves – 50 Hz, 2900 RPM Curvas de Funcionamiento – 50 Hz, 2900 RPM
METERS METROS
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
125
Model SST – 24ST / Size (Tamaño) 11⁄4 x 2-10 RPM 2900 Curve (Curva) CN0368R00 IMP. DWG. No. 452303131 (M)
FEET PIES
400 NPSHR – FEET (PIES) 4' 5' 40 45
350 100
A 101⁄16" DIA.
300
75
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
7' 50
B 9 ⁄16" 13
9' 11' 52 53
20' 53 52
C 9 ⁄4"
250
50
D 87⁄8" F 81⁄4"
200
20
G 77⁄8"
15
H 73⁄4"
50 150
71 ⁄2
10
HP
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia A B C D F G H
15'
1
Optional Impeller, Impulsor Opcional
HP
20 20 15 15 10 10 71⁄2
101⁄16" 913⁄16 91⁄4 87⁄8 81⁄4 77⁄8 73⁄4
NOTE: Pump will pass a sphere to 5⁄32" diameter.
HP
NOTA: La bomba pasará una esfera a 5⁄32" diámetro.
HP
100 25 50 NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
0 0
40
0
80
120 20
10
160 30
200
U.S. GPM 280
240
40
60 m3⁄hr
50
CAPACITY (CAPACIDAD) Q
METERS METROS
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
125
FEET PIES
Model SST – 25ST / Size (Tamaño) 11⁄2 x 21⁄2-10 RPM 2900 Curve (Curva) CN0369R00 IMP. DWG. No. 452303231 (M)
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
NPSHR – FEET (PIES)
400
5'
350 100
6' 8'
40
50
10'
55
A 101⁄16" DIA.
60
12' 62 63
62
C 9 ⁄16" 7
75
250 D 87⁄8"
25
E 87⁄16"
60
200 F 8 ⁄16"
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia A B C D E F G
15' 63
300 B 95⁄8"
Optional Impeller, Impulsor Opcional
HP
25 25 20 20 15 15 15
101⁄16" 95⁄8 97⁄16 87⁄8 87⁄16 81⁄16 73⁄4
1
20
G 73⁄4"
10
50 150
HP
15
NOTE: Pump will pass a sphere to 5⁄16" diameter.
HP
NOTA: La bomba pasará una esfera a 5⁄16" diámetro.
HP
100 25 50 NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
0 0 0
50 10
100 20
150 30
200 40
250 50
U.S. GPM 350
300 60
70
m3⁄hr
CAPACITY (CAPACIDAD) Q
13
Performance Curves – 50 Hz, 2900 RPM Curvas de Funcionamiento – 50 Hz, 2900 RPM
METERS METROS
Model SST – 22ST / Size (Tamaño) 21⁄2 x 3-8 RPM 2900 Curve (Curva) CN0366R00 IMP. DWG. No. 119-74
FEET PIES
250 70
40% EFF 50
A 91⁄16" DIA.
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 10' 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
6' NPSHR – FEET (PIES) 7' 8' 60
225 B 83⁄4" 65
C 81⁄2" D 81⁄4"
50
12'
15'
200 67
18'
65
68
G 71⁄2"
150 40
20'
60
175 E 77⁄8"
H 71⁄8"
40
125 J 611⁄16"
HP
K 61⁄2"
30
100
50
30
25
HP
20
75
20
50
15
10
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
0
100
0
20
200
300
40
60
400 80
A B C D E G H
40 30 30 25 20 20 15
91⁄16" 83⁄4 81⁄2 81⁄4 77⁄8 71⁄2 71⁄8
J
15
611⁄16
K
15
61⁄2
NOTA: La bomba pasará una esfera a 19⁄32" diámetro.
HP
HP
HP
500 100
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia
NOTE: Pump will pass a sphere to 19⁄32" diameter.
HP
10
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
60
Optional Impeller, Impulsor Opcional
600 140
120
U.S. GPM 700 m3⁄hr
CAPACITY (CAPACIDAD) Q
METERS METROS
Model SST – 27ST / Size (Tamaño) 21⁄2 x 3-10 RPM 2900 Curve (Curva) CN0371R00 IMP. DWG. No. 119-74
FEET PIES
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
400 NPSHR – FEET (PIES) 45% EFF
350 100 TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
6' 55
8'
60
A 103⁄8" DIA.
12'
68
300 B 915⁄16"
15' 69
C 99⁄16"
75
20'
68
65
250 D 91⁄4" E 83⁄4"
50
200 25
50
HP
40
150 30
100
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia A B C D E
10'
65
Optional Impeller, Impulsor Opcional
50 40 40 30 30
103⁄8" 915⁄16 99⁄16 91⁄4 83⁄4
NOTE: Pump will pass a sphere to 19⁄32" diameter.
HP
NOTA: La bomba pasará una esfera a 19⁄32" diámetro.
HP
HP
25 50
0
0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0 0
100 20
200 40
300 60
400 80
500 100
600 120
140
U.S. GPM 700 m3⁄hr
CAPACITY (CAPACIDAD) Q
14
Performance Curves – 50 Hz, 2900 RPM Curvas de Funcionamiento – 50 Hz, 2900 RPM
METERS METROS
Model SST – 23ST / Size (Tamaño) 3 x 4-8 RPM 2900 Curve (Curva) CN0367R00 IMP. DWG. No. 119-72
FEET PIES
250
50% EFF
70
9' 10' NPSHR – FEET (PIES)
60
A 91⁄16" DIA.
225
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
12' 72
70
B 811⁄16"
60
C 87⁄16"
200
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
15'
74
76 D 81⁄16"
50
20'
76 74
175
E 711⁄16"
72
F 71⁄2"
150
50
G 71⁄8"
40
7 125 H 6 ⁄8"
40
J 61⁄2"
70
30
HP
20
75
25 20
50
15
10 0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
200
0
400
600
80
40
120
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia A B C D E F G H
50 40 40 30 30 25 20 20
91⁄16" 811⁄16 87⁄16 81⁄16 711⁄16 71⁄2 71⁄8 67⁄8
J
15
61⁄2
NOTE: Pump will pass a sphere to 3⁄4" diameter.
HP
NOTA: La bomba pasará una esfera a 3⁄4" diámetro.
100 30
Optional Impeller, Impulsor Opcional
HP
HP
HP
HP
800
1000
160
200
1200 240
280
U.S. GPM 1400 m3⁄hr
CAPACITY (CAPACIDAD) Q
METERS METROS
Model SST – 28ST / Size (Tamaño) 3 x 4-10 RPM 2900 Curve (Curva) CN0372R00 IMP. DWG. No. 119-72
FEET PIES
Impeller Selection Key : Indicates stock pump impeller diameter for motor RPM and HP per price page. May utilize 1.15 motor service factor. For non-overloading at 1.0 S.F. select Option diameter. : Indicates optional diameter. See price list for ordering. Referencia de Selección del Impulsor : Indica el díametro del impulsor de la bomba en almacón para los HP y RPM del motor por página de precios. Puede utilizar 1,15 porcentaje de sobrecarga del motor. Para no sobrecarga a 1,0 S.F. seleccionar el diámetro de opción. : Indica diámetro opcional. Ver lista de precios para pedidos.
400
350
NPSHR – FEET (PIES)
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H
100
50% EFF
8' 65
C 9 ⁄16" DIA. 13
10' 70
12' 73
75
D 9 ⁄16"
250
14' 17'
75
7
75
E 9 ⁄16" 1
30
50
60
HP
50
150 40
HP
60 50 50 40
913⁄16" 97⁄16 91⁄16 811⁄16
NOTE: Pump will pass a sphere to 19⁄32" diameter.
20' 73
F 811⁄16"
200
Ordering Standard Code, HP Rating, Dia. Código Estándar HP de Pedido Potencia C D E F
9'
60
300
Optional Impeller, Impulsor Opcional
NOTA: La bomba pasará una esfera a 19⁄32" diámetro. HP
HP
100 25 50
0
0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0 0
200 40
400 80
600 120
800 160
1000 200
1200 240
280
U.S. GPM 1400 m3⁄hr
CAPACITY (CAPACIDAD) Q
15
SST Close Coupled – Materials of Construction SST Acople Cerrado – Materiales de Construcción 101
100
178
370
108
103
SST Frame Mounted – Materials of Construction SST Armazón Montado – Materiales de Construcción 100
101
513
370
184
383 108
228
513 134 184
370C 333A
383
198 199
408 126
Item No., Description, Parte No. Descripción
371
103 Materials, Materiales
198 199
408
178
126
370B 123
168
Item No., Description, Parte No. Descripción
112
193 382 371
Materials, Materiales
100
Casing, Carcasa
100
Casing, Carcasa
101
Impeller, Impulsor
101
Impeller, Impulsor
103
Wear ring, Anillo de desgaste
103
Wear ring, Anillo de desgaste
184
Seal housing, Alojamiento del sello
184
Seal housing, Alojamiento del sello
126
Shaft sleeve, Camisa del eje
126
Shaft sleeve, Camisa del eje
178
Impeller key, Llave del impulsor
178
Impeller key, Llave del impulsor
198
Impeller bolt, Tornillo del impulsor
198
Impeller bolt, Tornillo del impulsor
199
Impeller washer, Arandela del impulsor
199
Impeller washer, Arandela del impulsor
370
Casing bolt with nut (casing to adapter), Tornillo de la carcasa con tuerca (carcasa para adaptador)
370
Casing bolt with nut, Tornillo de la carcasa con tuerca
408
Drain plug – 3⁄8 NPT, Válvula de drenaje – 3⁄8 NPT
513
O-ring, Anillo ‘O’
BUNA-N
383
Mechanical seal, standard part No. 10K16, Sello mecánico, parte estándar Número 10K16
Carbon/ceramic BUNA-N elastomers 300 SS metal parts, Carbón/cerámica elastómeros BUNA-N partes metálicas 300 SS
108
Adapter, Adaptador
228
Bearing frame, Armazón de balineras
134
Bearing cover, Cubierta de balineras
Cast iron ASTM A48CL20, Hierro fundido ASTM A48CL20
122
Pump shaft, Eje de la bomba
168
Ball bearing (inboard), Balineras de bolas (interior)
112
Ball bearing (outboard), Balineras de bolas (exterior)
382
Retaining ring, Anillo de sujeción
370B
Hex head cap screw (adapter to bearing frame), Tornillo de cabeza hexagonal (adaptador para armazón de balineras)
370C
Hex head cap screw (bearing frame to cover), Tornillo de cabeza hexagonal (armazón de balineras para cubierta)
108
371
AISI 300 series SS, AISI 300 series acero inoxidable
Adapter, Adaptador
Cast iron ASTM A48 CL20, Hierro fundido ASTM A48CL20
Hex head cap screw (adapter to motor), Tornillo de cabeza hexagonal (adaptador para motor)
Steel SAE 1200 series, Acero SAE series 1200
513
O-ring, Anillo 'O'
BUNA-N
408
Drain plug – 3⁄8 NPT, Válvula de drenaje – 3⁄8 NPT AISI 304 SS, AISI 304 acero inoxidable
383
Mechanical seal, Sello mecánico
See seal chart, Ver tabla del sello
Mechanical Seal, Sello Mecánico John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Item, Parte
383 Options, 383 Opciones
Part No., Pleza Número
Metal Intended Rotary, Stationary, Elastomers, Parts, Duty, 180-210 250-360 Rotativo Estacionario Elastómeros Partes Servicio Frames, Frames, Metálicas Propuesto Armazones Armazones 10K13
10K16
Ceramic
BUNA
10K19
10K20
Ni-Resist
EPR
10K25
10K26
10K27
10K45
Carbon
Ceramic Viton Tung. Carb.
Standard 316 SS, Hi–Temp. 316 Chemical Acero inoxidable Mild Abrasive
AISI 300 series SS, AISI 300 series acero inoxidable
AISI 300 series SS, AISI 300 series acero inoxidable
Steel, Acero
333A
Lip seal, Sello cubierto
BUNA-N
193
Grease fitting, Accesorio de grasa
Steel, Acero
123
V-ring deflector, Deflector anillo ‘V’
BUNA-N
16
SST-F – Engineering Data SST-F – Información Técnica Channel Steel Bedplate, Clockwise Rotation Viewed from Drive End; Fundación de Acero, Rotación en Dirección de las Agujas del Reloj Visto desde el Extremo del Motor CP AB MAX.
DISCHARGE DESCARGA
33⁄4
C MAX. SPACER COUPLING ACOPLE DEL ESPACIADOR COUPLING GUARD, GUARDA ACOPLE
51⁄8
Y
37⁄8 1.625 DIA. 1.624
X
SINGLE PHASE ONLY, SOLO UNIFÁSICOS
SUCTION SUCCIÓN
P MAX.
DC DD MAX.
HD
KEYWAY 3⁄16 x 3⁄8 CHAVETERO 3⁄16 x 3⁄8
HG HE
3
⁄8 NPT L
HE
(4) HOLES 5 ⁄8 DIA. (4) AGUJEROS 5 ⁄8 DIA. 13⁄4
HF HB
HA
Dimensions and Weights – Determined by Pump, Dimensiones y Pesos – Determinados por la Bomba Pump Size, Tamaño de Suction*, Discharge*, CP la Bomba Succión* Descarga* 11⁄4 x 2-10 1 ⁄2 x 2 1⁄2-10 2 x 2 1⁄2-8 2 x 2 1⁄2-10 21⁄2 x 3-8 21⁄2 x 3-10 3 x 4-8 3 x 4-10
11⁄4 11⁄2
2
1
21⁄2
2
23
21⁄2
3 4
3
24
DC Max., DC DD Máx.
L
X
67⁄8
65⁄8
61⁄8 67⁄8 61⁄8
57⁄8 715⁄16 101⁄2 4 5 6 ⁄8 815⁄16 57⁄8
67⁄8
65⁄8
815⁄16
915⁄16 1
75⁄8
73⁄8
11 ⁄2
NOTE: All pumps shipped in vertical discharge position. May be rotated in 90° increments. Tighten 3⁄8 – 16 casing bolts to 15 ft./lbs. torque. 1⁄2 – 13 bolts to 30 ft./lbs.
Wt. (lbs.), Y Peso (libras)
5
111⁄8
125 125 120 125 125 134 136 148
NOTA: Todas las bombas transportadas en posición de descarga vertical. Pueden rotarse en aumentos de 90 °. Apretar 3⁄8 – 16 tornillos de carcasa a 15 pies/libras potencia. 1 ⁄2 – 13 tuercas a 30 pies/libras.
* For use with ANSI class 150 mating flanges. * Para usar con bridas que casan ANSI clase 150.
Available Motor and Bedplate Dimensions and Weights, Pesos y Dimensiones Disponibles de la Fundación y del Motor Motor Frame, Armazón del Motor
HP @ 3500 RPM Three Phase, Trifásicos ODP
TEFC
184T 213T
Single Phase, Monofásicos
Three Phase, Trifásicos
ODP
TEFC
ODP
TEFC
3 or 5
3
5
5
1
7 ⁄2
1
7 ⁄2
10
10
215T
15
254T
20
15
15
15
256T
25
20
20
20
284TS/T
30
25
25
25
286TS/T
40
30
324TS/T
50
40
326TS/T
60
50
364TS/T
75
60
Bedplate Data, Datos de la Fundación
HP @ 1750 RPM – T-Frame Only AB C Max., Max., AB C Máx. Máx. 57⁄8
181⁄8
365TS/T
100
75 100
77⁄8
18 73⁄8 91⁄2 125⁄8
191⁄8 215⁄8 233⁄8 247⁄8 265⁄8 1
30 ⁄4
95⁄8 13 15
18
HB
HD
HE
HF
HG
Wt. (lbs.), Peso (libras)
13
42
101⁄4
51⁄4
381⁄2
4
111
15
44
101⁄2
53⁄4
401⁄2
31⁄2
124
71⁄4
441⁄2
4
183
71⁄4
521⁄2
4
214
95 136 266 264 392 422 592
173⁄8
315⁄8 15 ⁄8
HA
116
283⁄4 141⁄8 1
405TS/T
P Wt. Max., Max., P Peso Máx. Máx.
12
634 834
18
48
7
5
32 ⁄8 367⁄8
18 ⁄8 205⁄8
13
1000 1060
22
56
14
Dimensions and weights vary with manufacturers. Dimensions in inches and weights in lbs. Dimensiones y pesos varían con los fabricantes. Dimensiones en pulgadas y pesos en libras.
17
SST Close Coupled – Dimensions and Weights SST Acople Cerrado – Dimensiones y Pesos (All dimensions in inches and weights in lbs. Do not use for construction purposes.) (Todas las dimensiones en pulgadas y pesos en libras. No usar para propósitos de construcción.) CP MAX. DISCHARGE DESCARGA
AB MAX.
W
Y
X SUCTION SUCCIÓN P MAX.
G
D
DC DD MAX.
L
E
E
F
3
⁄8" NPT
A
11⁄4 x 2-10 11⁄2 x 21⁄2-10 2 x 21⁄2-8 2 x 21⁄2-10 21⁄2 x 3-8 21⁄2 x 3-10 3 x 4-8 3 x 4-10
2
11⁄4 11⁄2
21⁄2 3
341⁄2
2 36
1
2 ⁄2
4
3
37
Wt. Motor Frame Size, (lbs.), Tamaño del Armazón del Motor Y Pesos (libras) 140 180 210 250 280 320 360
DD
X
67⁄8
65⁄8
815⁄16
61⁄8 67⁄8 61⁄8
57⁄8 65⁄8 57⁄8
715⁄16
67⁄8
65⁄8
915⁄16
75⁄8
73⁄8
111⁄8
75
101⁄2
67 75 72 84 86 98
4
15
8 ⁄16
5
111⁄8 121⁄8
137⁄8
145⁄8
* For use with ANSI class 150 mating flanges. * Para usar con bridas que casan ANSI clase 150.
Dimensions Determined by JM Motor Frame, Dimensiones Determinadas por el Armazón del Motor JM Frame, Armazón 145JM 182JM 184JM 213JM 215JM 254JM 256JM 284JM 286JM 324JM 326JM 364TCZ 365TCZ
A
AB
B
D
E
F
61⁄2
51⁄4
6
31⁄2
23⁄4
81⁄2
57⁄8
61⁄2
41⁄2
33⁄4
21⁄2 21⁄4
G 1 3
⁄8
1
11 ⁄4
73⁄8 9
121⁄4 121⁄4 14
131⁄4
173⁄4 151⁄8
8 3
11 ⁄4
51⁄4
41⁄4
1
5
6 ⁄4
121⁄4
7
51⁄2
14
8
61⁄4
151⁄2
9
7
7 1
3 ⁄2 41⁄8 5 43⁄4 51⁄2 51⁄4 51⁄2 55⁄8 61⁄8
11
⁄32
13
⁄32
P Max., P Máx.
W
65⁄8 35⁄8
95⁄8
⁄32
111⁄2 1
⁄4
17
⁄32 131⁄4 51⁄8
5
151⁄8
⁄16 21
1
147⁄8
153⁄8
16
NOTES: 1. Pumps shipped in vertical discharge as standard. For other orientations, remove casing bolts, rotate discharge to desired position, and tighten 3⁄8 – 16 bolts to 15 ft./lbs., 1⁄2 – 13 bolts to 35 ft./lbs. 2. ALL dimensions in inches. 3. Not for construction purposes.
NOTAS: 1. Las bombas se transportarán en descarga vertical como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 15 pies/libras, 1⁄2 – 13 tornillos a 35 pies/libras. 2. TODAS las dimensiones en pulgadas. 3. No para propósitos de construcción.
Motor Frame Selections, Selecciones del Armazón del Motor
77⁄8
⁄16
23⁄4 91⁄2
H
143⁄8 15
121⁄8
H-(4) HOLES H-(4) AGUJEROS
B
Dimensions “L” Determined by Pump and Motor, Dimensiones “L” Determinadas por la Bomba y el Motor Pump CP DC Suction*, Disch.*, Max., Max., Size, DC Tamaño Succión Descarga CP Máx. Máx. de la Bomba
F
⁄32 19
364TCZ and 365TCZ frames are built with 326JM shaft extensions. Dimensions may vary with manufacturer. Los armazones 364TCZ y 365TCZ se construyen con extensiones del eje 326JM. Las dimensiones puede que varíen con los fabricantes.
Frame, Armazón 145JM 182JM 184JM 213JM 215JM 254JM 256JM 284JM 286JM 324JM 326JM 364TCZ 365TCZ
Motor Horsepower, Potencia del Motor Wt. Max., 3500 RPM 1750 RPM 3 PH, Trifásicos 1 PH, Monofásicos 3 PH, Trifásicos Peso Máx. ODP TEFC ODP TEFC ODP TEFC – – – – 2 2 57 – – 2 2-3 3 3 77 – – 3 – 5 5 97 – – 5 – 71⁄2 71⁄2 122 15 – – – 10 10 155 20 15 – – 15 15 265 25 20 – – 20 20 320 30 25 – – 25 25 419 40 30 – – – – 422 50 40 – – – – 562 60 50 – – – – 625 75 60 – – – – 775 100 100, 75 – – – – 905
364TCZ and 365TCZ frames are built with 326JM shaft extensions. Los armazones 364TCZ y 365TCZ se construyen con extensiones del eje 326JM.
18
SST Frame Mounted – Dimensions and Weights SST Armazón Montado – Dimensiones y Pesos CP 51⁄8
Y
X
37⁄8 1.625 DIA. 1.624
DC MAX.
61⁄4
KEYWAY 3⁄16 x 3⁄8, CHAVETERO 3⁄16 x 3⁄8 DD
9
⁄16 DIA. – (4) HOLES ⁄16 DIA. – (4) AGUJEROS
9
1
31⁄2
L
31⁄2 3
61⁄2
⁄2
1
⁄8 NPT 81⁄2
81⁄2
Dimensions and Weights – Bare Pump Only, Dimensiones y Pesos – Solamente Bomba Pump Size, Tamaño de Suction*, Discharge*, CP la Bomba Succión* Descarga* 11⁄4 x 2-10 11⁄2 x 2 1⁄2-10 2 x 2 1⁄2-8 2 x 2 1⁄2-10 21⁄2 x 3-8 21⁄2 x 3-10 3 x 4-8 3 x 4-10
2 21⁄2
3 4
11⁄4 11⁄2 2
23
21⁄2 3
24
DC Max., DC DD Máx.
L
X
Wt. (lbs.), Y Peso (libras)
67⁄8
65⁄8
815⁄16
61⁄8 67⁄8 61⁄8
57⁄8 715⁄16 101⁄8 4 65⁄8 815⁄16 57⁄8
67⁄8
65⁄8
915⁄16 1
75⁄8
73⁄8
11 ⁄8
111⁄8
5
125 125 120 125 125 134 136 148
NOTES: 1. Pumps will be shipped with top vertical discharge as standard. For other orientations, remove casing bolts, rotate discharge to desired position, and tighten 3⁄8 –16 bolts to 15 ft./lbs., 1⁄2 – 13 bolts to 35 ft./lbs. 2. ALL dimensions in inches. 3. Not for construction purposes.
NOTAS: 1. Las bombas se transportarán con la descarga vertical superior como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 15 pies/libras, 1⁄2 – 13 tornillos a 35 pies/libras. 2. TODAS las dimensiones en pulgadas. 3. No para propósitos de construcción.
* For use with ANSI class 150 mating flanges. * Para usar con bridas que casan ANSI clase 150.
19
Specifications Especificaciones Capacities to: 1100 GPM (250 m3/hr) at 3500 RPM 775 GPM (177 m3/hr) at 1750 RPM Heads to: 520 feet THD (158 m) at 3500 RPM 130 feet THD (40 m) at 1750 RPM Maximum working pressures to: 230 PSI (15 bars) Maximum temperatures to: 212°F (100°C) with standard seal or 250°F (121°C) with optional high temperature seal. All wetted components of AISI: Type 304 stainless steel material. Rotation: Clockwise when viewed from motor end. Enclosed impeller and replaceable wear ring: for high efficiency and maximum wear life. Motor (close coupled): NEMA standard JM shaft open drip-proof, totally enclosed and explosion-proof enclosures, 60 Hz, 1750 or 3500 RPM. Single phase ODP (115/230 V) 1750 RPM, 2 – 5 HP.
Three phase ODP. TEFC/Exp. proof (208 – 230/460 V). 3500 RPM, 15 – 100 HP 1750 RPM, 2 – 75 HP NOTE: Overload protection must be provided. Contactor with overload for single phase or starter with heaters for three phase ordered separately. Motor (frame mounted): NEMA standard T-frame open drip-proof, totally enclosed and explosion-proof (three phase only) enclosures 60 Hz, 1750 or 3500 RPM. Single phase (115/230 V) 1750 RPM, 3 – 5 HP Three phase (208 – 230/460 V) 3500 RPM, 15 – 100 HP 1750 RPM, 5 – 70 HP NOTE: Overload protection must be provided. Contactor with overload for single phase or starter with heaters for three phase ordered separately. Optional: Rigid carbon steel bedplate, sheet metal coupling guard designed to OSHA specifications and T.B. WOODS type “SC” spacer couplings.
Capacidades: 1100 GPM (250 m3/hr) a 3500 RPM 775 GPM (177 m3/hr) a 1750 RPM Cargas: 520 pies THD (158 m) a 3500 RPM 130 pies THD (40 m) a 1750 RPM Presión de trabajo máxima: 230 PSI (15 baras) Temperatura máxima: 212°F (100°C) con sello estándar o 250°F (121°C) con sello opcional para alta temperatura. Todos los componentes mojados de AISI: Material de acero inoxidable tipo 304. Rotación: En dirección de las agujas del reloj visto desde el extremo final del motor. Impulsor encerrado y anillo de desgaste reemplazable: para alta eficiencia y máxima durabilidad. Motor (acople cerrado): Eje a prueba de goteo JM estándar NEMA, totalmente encerrado y recintos a prueba de explosión, 60 Hz, 1750 ó 3500 RPM. Unifásicos ODP (115/230 V) 1750 RPM, 2 – 5 HP
Trifásicos ODP. TEFC/a prueba de explosión (208 – 230/460 V). 3500 RPM, 15 – 100 HP 1750 RPM, 2 – 75 HP NOTA: Se debe de proporcionar protección térmica contra sobrecarga. Contactor con protección térmica contra sobrecarga para unifásicos o arrancadores con calentadores para trifásicos se piden por separado. Motor (armazón montado): Armazón abierto T a prueba de goteo estándar NEMA, totalmente encerrado y recintos a prueba de explosión (trifásicos solamente) 60 Hz, 1750 ó 3500 RPM. Unifásicos (115/230 V) 1750 RPM, 3 – 5 HP. Trifásicos (208 – 230/460 V) 3500 RPM, 15 – 100 HP 1750 RPM, 5 – 70 HP NOTA: Se debe de proporcionar protección térmica contra sobrecarga. Contactor con protección térmica contra sobrecarga para unifásicos o arrancadores con calentadores para trifásicos se piden por separado. Opcional: Fundación rígida de acero al carbono, guarda acople de metal laminado diseñado según las especificaciones OSHA y acoples del espaciador T.B. WOODS tipo “SC”.
Typical Applications Aplicaciones Típicas Specifically designed for all traditional cast iron or bronze fitted water and low grade corrosive services.
Diseñada específicamente para todos los servicios de agua de hierro fundido o recubiertas de bronce y servicios corrosivos de bajo grado.
• Water circulation
• Circulación de Agua
• Booster systems
• Aumento de presión
• Liquid transfer
• Transferencia de líquidos
• HVAC pump replacements
• Reemplazos para bombas HVAC
• General service pumping
• Bombeo de servicios generales
HVAC, Calefacción, Ventilación y Aire Acondicionado
Tubing washer, Arandela de tubería
© 1996 Goulds Pumps Printed in USA GLSST
Goulds Pumps 240 Fall Street Seneca Falls, NY 13148
Water truck, Camión cisterna
Printed on recycled paper.
View more...