GouldPumpSpecs

March 18, 2018 | Author: Cristhyam Vargas | Category: Hydraulic Engineering, Gases, Building Engineering, Civil Engineering, Hydraulics
Share Embed Donate


Short Description

Download GouldPumpSpecs...

Description

IT T

Commercial Water

Goulds Pumps G&L Series SSH

S & M-Group 316 Stainless Steel End Suction Pumps Bombas de Succión Final de 316 Acero Inoxidable Grupo-M y S

Goulds Pumps is a brand of ITT Residential and Commercial Water. Goulds Pumps es una marca de fábrica de ITT Agua Residencial y Industrial. www.goulds.com

Engineered for life

A Full Range of Product Features, Una Gama Total de Características del Producto Superior Materials of Construction: AISI Type 316L stainless steel pump parts for reduced corrosion and improved strength and ductility. Frame Mounted Design: Flexibility of installation and driver arrangements. Back Pull-Out Design: Simplifies maintenance when used with spacer type coupling. Cast Iron Power Frame: Rigidly supported, grease lubricated ball bearing assembly. Mechanical Seal: Standard John Crane Type 21 mechanical seal.

GOULDS PUMPS Commercial Water

Drive Motors: Standard NEMA design T-frame or JM motors in single or three phase. Suction and Discharge Flanges: Mate with ANSI class 150 flanges. Close-Coupled Design: Compact design saves space and simplifies maintenance.

Materiales Superiores de Construcción: Partes de la bomba de acero inoxidable AISI Tipo 316L para corrosión reducida y fuerza y ductilidad mejoradas. Diseño de Armazón Montado: Flexibilidad de instalación y colocación del motor. Diseño de Extracción Trasera: Simplifica el mantenimiento cuando se usa con el acople tipo espaciador.

Motores de Accionamiento: Motores de armazón-T NEMA estándar unifásicos o trifásicos. Bridas de Succión y Descarga: Acoplan con bridas ANSI clase 150. Diseño de Acople Cerrado: El diseño compacto ahorra espacio y simplifica el mantenimiento.

Armazón del Motor de Hierro Fundido: Rígidamente soportado, con ensamblaje de balineras de bolas lubricadas con grasa . Sello Mecánico: Sello mecánico estándar John Crane Tipo 21.



Performance Coverage, 3500 and 1750 RPM Alcance de Funcionamiento, 3500 y 1750 RPM METERS (METROS)

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL)

175

150 125

FEET (PIES) 600

3500 RPM

500

400

100 300

27SH

24SH

28SH

11SH 25SH

75 200

23SH 10SH

50 25

0

100

8SH

9SH

6SH 5SH

4SH

0 0 0

METERS (METROS)

22SH

7SH

100

200

20

300

40

60

400 80

600

500

100

700

800

120 140 160 180 CAPACITY (CAPACIDAD) – U.S. GPM

900 200

1000 220

FEET (PIES) 150

1100 240

1200

260 m3/hr

1750 RPM

40

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL)

125

30

100

75 20 50 10

24SH 11SH

25

28SH

10SH

9SH

7SH

0 0 0

8SH

22SH

100 20

23SH

6SH

5SH

4SH

0

27SH

25SH

200 40

300 60

400

500

80 100 120 CAPACITY (CAPACIDAD) – U.S. GPM

600 140

700

800

160 m3/hr 180

GOULDS PUMPS Commercial Water



SSH S/M-Group Numbering System Sistema de Numeración del Grupo-S/M SSH Example Product Code, Ejemplo Código del Producto 24 SH 1 Q 1 2 A 0 Mechanical Seals and O-Ring 0 = Pre-engineered standard For optional mechanical seal modify catalog order no. with seal code listed below. Sello Mecánico y Anillo ‘0’ 0 = Estándar aprobado Para sello mecánico opcional modificar el número de orden del catálogo con el código del sello anotado abajo. John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Seal Code, Código del Sello

Rotary, Rotativo

Stationary, Estacionario

Elastomers, Elastómeros

0 Carbon Sil-Carb 2 5 Sil-Carb Sil-Carb

Part No., Pieza Número Metal Parts, 180-210 250-360 Partes Frames, Frames, Metálicas Armazones Armazones

Viton EPR Viton

316 SS, 316 Acero inoxidable

10K27 10K19 10K64

10K45 10K20 10K65

Impeller Option Code For optional impeller diameters modify catalog order no. with impeller code listed below. Select optional impeller diameter from pump performance curve. Código del Impulsor Opcional Para diámetros del impulsor opcional modificar el número de orden del catálogo con el código del impulsor anotado abajo. Seleccionar el diámetro del impulsor opcional de la curva de funcionamiento de la bomba. Pump Size, Tamaño de la Bomba Impeller Code, 9SH 10SH 11SH 4SH 7SH 5SH 8SH 6SH 22SH 23SH 24SH 25SH 27SH 28SH Código del 1 x 2-6 1 x 2-8 1 x 2-10 1½ x 2½-6 1½ x 2½-8 2 x 2½-6 2 x 2½-8 2½ x 3-6 2½ x 3 – 8 3 x 4 – 8 1½ x 2½ – 10 2 x 2½ – 10 2½ x 3 – 10 3 x 4 – 10 impulsor Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. A 65⁄8 827⁄64 103⁄32 6¾ 81⁄4 67⁄8 8¼ 75⁄16 91⁄16 91⁄16 97⁄8 97⁄8 103⁄8 105⁄8 B 67⁄16 81⁄16 917⁄32 63⁄8 713⁄16 67⁄16 7¾ 71⁄8 8¾ 811⁄16 9½ 9½ 915⁄16 10¼ 11 11 1 1 13 15 7 3 1 C 5 ⁄16 7 ⁄16 9 ⁄8 6 ⁄16 7 5 ⁄16 7½ 6 ⁄16 8½ 8 ⁄16 9 ⁄16 9 ⁄8 99⁄16 913⁄16 D 53⁄8 73⁄8 8¾ 55⁄8 6¾ 5½ 73⁄16 611⁄16 8¼ 81⁄16 87⁄8 813⁄16 9¼ 97⁄16 1 5 7 1 7 3 7 11 9 3 E 7 ⁄8 5 ⁄16 6 ⁄16 5 ⁄8 6 ⁄8 6 ⁄8 7 ⁄8 7 ⁄16 8 ⁄16 8 ⁄16 8¾ 91⁄16 F 411⁄16 61⁄8 413⁄16 63⁄16 61⁄16 7½ 7½ 8¼ 715⁄16 811⁄16 G 43⁄8 47⁄16 55⁄8 71⁄8 71⁄8 711⁄16 H 43⁄16 4¼ 611⁄16 67⁄8 J 37⁄8 6½ 6½ K 6 L 5½

Motor Enclosure, Caja del motor 1 = ODP 5 = TEFC Premium Eff., Eficiencia superior 2 = TEFC 6 = XP Premium Eff., Eficiencia superior 3 = Explosion Proof, Prueba de explosiones 7 = Wash down, Lavado 4 = ODP Premium Eff., Eficiencia superior Motor Voltage, Voltaje del motor 1 = 115/208-230 3 = 230 2 = 115/230 4 = 230/460

5 = 208-230/460 6 = 460

HP Rating, Potencia nominal, HP C = ½ F = 1.5 J = 5 M = 15 D = .75 G = 2 K = 7.5 N = 20 E = 1 H = 3 L = 10 P = 25

Q = 30 R = 40 S = 50

7 = 575

T = 60 U = 75 V = 100

Frame Options, Opciones de mando Substitute, Description, Substituto Descripción 7/8" Imp. Bore, Diámetro FRM2 interior del impulsor 7/ " 8 11/4" Imp. Bore, Diámetro FRM3 interior del impulsor 11/ " 4

Driver: Hertz/Pole/RPM, Fuerza motriz: Hertz/Polos/RPM 1 = 60/3500/1 3 = 60/1750/1 5 = 50/2900/1 2 = 60/3500/3 4 = 60/1750/3 6 = 50/2900/3 Material SH = 316L Stainless steel, Acero inoxidable Pump Size, Tamaño de la Bomba 9 = 1 x 2 – 6 4 = 1½ x 2½ – 6 10 = 1 x 2 – 8 7 = 1½ x 2½ – 8 11 = 1 x 2 – 10 5 = 2 x 2½ – 6 23 = 3 x 4 – 8 24 = 1½ x 2½ – 10 27 = 2½ x 3 – 10 28 = 3 x 4 – 10

GOULDS PUMPS Commercial Water

8 = 2 x 2½ – 8 6 = 2½ x 3 – 6 22 = 2½ x 3 – 8 25 = 2 x 2½ – 10

NOTE: Not all combinations of motor, impeller and seal options are available for every pump model. Please check with G&L on non-cataloged numbers. NOTA: No todas las combinaciones de las opciones de motor, impulsor y sello están disponibles para cada modelo de bombas. Por favor verifique con G&L en los números no catalogados.



Performance Curves – 60 Hz, 3500 RPM Curvas de Funcionamiento – 60 Hz, 3500 RPM METERS METROS

60

Model SSH / 9SH Size (Tamaño) 1 x 2-6 RPM 3500 Curve (Curva) CN0619R00

FEET PIES

200

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

5' NPSHR – FEET (PIES) 39

A 65⁄8" DIA.

50

B 6 ⁄16" 7

150

10'

54

40



8'

49

56 EFF%

C 511⁄16"

65⁄8" 67⁄16 511⁄16 53⁄8

5 5 3 3

NOTE: Pump will pass a sphere to 1⁄8" diameter. NOTA: La bomba pasará una esfera a 1⁄8" diámetro.

D 53⁄8"

30

A B C D

100

20

5 HP

50

3 HP

10

0

0 0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

25

0

50

5

75

10

100

15

125

20

25

U.S. GPM 150

30

m3⁄ hr

CAPACITY (CAPACIDAD) (Q)

METERS METROS

90

FEET PIES

300

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

80

Model SSH / 10SH Size (Tamaño) 1 x 2-8 RPM 3500 Curve (Curva) CN0613R00

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 827⁄64" DIA.



250 B 81⁄16" 70

60

6' NPSHR – FEET (PIES) 10' 42

33

C 711⁄16"

200

14' 18'

47

22'

D 73⁄8"

827⁄64" 81⁄16 711⁄16 73⁄8 71⁄8"

10 10 7½ 7½ 7½

NOTE: Pump will pass a sphere to 1⁄8" diameter. NOTA: La bomba pasará una esfera a 1⁄8" diámetro.

49 42 EFF%

E 71⁄8"

50

A B C D E

150 40

30

100

20 50 0 0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

25 5

50 10

75 15

71⁄2 HP

100 20

125 25

150 30

35

10 HP

175 U.S. GPM 200 40

m3⁄ hr

CAPACITY (CAPACIDAD) (Q)

GOULDS PUMPS Commercial Water



Performance Curves – 60 Hz, 3500 RPM Curvas de Funcionamiento – 60 Hz, 3500 RPM

METERS METROS

FEET PIES

450 130

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

120

NPSHR – FEET (PIES)

3 400 A 10 ⁄32" DIA.

30

17 350 B 9 ⁄32"

90 80

43

25'

27'

100 300

250



22’

38

110

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

Model SSH / 11SH Size (Tamaño) 1 x 2-10 RPM 3500 Curve (Curva) CN0616R00

C 91⁄8"

45

103⁄32" 917⁄32 91⁄8 8¾

20 15 15 15

NOTE: Pump will pass a sphere to 1⁄8" diameter. NOTA: La bomba pasará una esfera a 1⁄8" diámetro.

29' 43 EFF%

D 83⁄4"

A B C D

70 60 50

200 10 HP

150

20 HP

40 30 20

100 50 0

15 HP

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

25

0

50

5

10

75

100

15

20

125 25

150 30

175 U.S. GPM 200

35

40

m3⁄ hr

CAPACITY (CAPACIDAD) (Q)

METERS METROS

Model SSH / 4SH Size (Tamaño) 11⁄2 x 21⁄2- 6 RPM 3500 Curve (Curva) CN0488R01

FEET PIES

60

5' NPSHR – FEET (PIES)

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

175 50

55

A 6 ⁄4" DIA. 3

8'

59 61

B 6 ⁄8" 3

150 40

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia 63



65

C 61⁄16" 65 12'



125 D 55⁄8"

61 EFF%

E 55⁄16"

30

100

20



6¾" 63⁄8 61⁄16 55⁄8 55⁄16

10 7½ 7½ 5 5

F G H J

411⁄16 43⁄8 43⁄16 33⁄8

3 3 2 2

NOTE: Pump will pass a sphere to 3⁄16" diameter. NOTA: La bomba pasará una esfera a 3⁄16" diámetro.

7 ⁄ HP 12

H 43⁄16"

50 J 37⁄8"

0



10 HP

F 411⁄16" 75 G 43⁄8"

10



63

A B C D E

5 HP 3 HP

25

0 0 0

2 HP

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

50 10

100 20

150 30

200 40

250 U.S. GPM 50

60 m3⁄ hr

CAPACITY (CAPACIDAD) (Q)

GOULDS PUMPS Commercial Water



Performance Curves – 60 Hz, 3500 RPM Curvas de Funcionamiento – 60 Hz, 3500 RPM

METERS METROS

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

80

Model SSH / 7SH Size (Tamaño) 11⁄2 x 21⁄2-8 RPM 3500 Curve (Curva) CN0491R00

FEET PIES

1 275 A 8 ⁄4" DIA.

6' NPSHR – FEET (PIES)

40

60 50

30 20

55

56 57

225

8' 58 59 10'

200 C 7"



14'

D 63⁄4"

175 E 67⁄16" 150

40



50

250 B 713⁄16" 70

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

59

F 61⁄8"



58

100

8¼" 713⁄16 7 6¾ 67⁄16 61⁄8

15 15 10 10 7½ 7½

NOTE: Pump will pass a sphere to 3⁄16" diameter. NOTA: La bomba pasará una esfera a 3⁄16" diámetro.

57 EFF%

15 HP

125

A B C D E F

10 HP 71⁄2 HP

75 50

10 0

25 0 0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

25

0

50

75

10

100

125

20

150

175

30

200

225

40

250

50

275 U.S. GPM 60

m3⁄ hr

CAPACITY (CAPACIDAD) (Q)

METERS METROS

Model SSH / 5SH Size (Tamaño) 2 x 21⁄2- 6 RPM 3500 Curve (Curva) CN0494R01

FEET PIES

60

50

A 67⁄8" DIA.

6' NPSHR – FEET (PIES) 60

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

175

64

B 67⁄16"

50

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

66 67

150 40

30

14'

68 C 5 ⁄16" 13

125 100 75

20 50



10'

68 19' 67

D 51⁄2"



66 EFF%

E 51⁄8"



F 413⁄16"

H 41⁄4"

67⁄8" 67⁄16 513⁄16 5½ 51⁄8

15 15 10 10 7½

F G H

413⁄16 47⁄16 4¼

7½ 5 5

NOTE: Pump will pass a sphere to 5⁄32" diameter. NOTA: La bomba pasará una esfera a 5⁄32" diámetro.

15 HP

G 47⁄16"

A B C D E

10 HP 71⁄2 HP

10

0

25 0 0 0

5 HP

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

50

100 20

150

200 40

250

300 60

350 80

400

U.S. GPM

100

m3⁄ hr

CAPACITY (CAPACIDAD) (Q)

GOULDS PUMPS Commercial Water



Performance Curves – 60 Hz, 3500 RPM Curvas de Funcionamiento – 60 Hz, 3500 RPM Model SSH / 8SH Size (Tamaño) 2 x 21⁄2- 8 RPM 3500 Curve (Curva) CN0497R01

METERS METROS

FEET PIES

90

300

8' NPSHR – FEET (PIES) 50

A 81⁄4" DIA. TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

60

10'

65



69

80 250 70

71

B 73⁄4"

13'

C 71⁄2"

16'

D 7 ⁄16" 3

60

200

50 150



71

E 67⁄8"

21'



69

8¼" 7¾ 7½ 73⁄16 67⁄8 63⁄16

25 20 20 15 15 10

NOTE: Pump will pass a sphere to ¼" diameter. NOTA: La bomba pasará una esfera a ¼" diámetro.

65 EFF%

F 63⁄16"

A B C D E F

40 25 HP

30

10 HP

100

20 HP

15 HP

20 50 10 0

0 0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

50

100

0

150

20

200

250

40

300

350

60

400

U.S. GPM

80

100

m3⁄ hr

CAPACITY (CAPACIDAD) (Q)

METERS METROS

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

80

Model SSH / 6SH Size (Tamaño) 21⁄2 x 3-6 RPM 3500 Curve (Curva) CN0500R00

FEET PIES

7' NPSHR – FEET (PIES)

250 60

70 60

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 75⁄16" DIA.

200

65

B 71⁄8" C 615⁄16"

8' 70 70

10' 68

D 611⁄16"

13'

E 63⁄8"

50

66

150 F 61⁄16" 40 30

20'

G 55⁄8"

25' 63

100

60 EFF%

50

20 HP

20

75⁄16" 71⁄8 615⁄16 611⁄16 63⁄8

25 25 20 20 15



F G

61⁄16 55⁄8

15 10

NOTE: Pump will pass a sphere to 5⁄16" diameter. NOTA: La bomba pasará una esfera a 5⁄16" diámetro.

25 HP

10 0

A B C D E



15' 65



15 HP

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0 0 0

100 25

200 50

300

10 HP

400 75

500 100

600 125

700 150

U.S. GPM m3⁄ hr 175

CAPACITY (CAPACIDAD) (Q)

GOULDS PUMPS Commercial Water



Performance Curves – 60 Hz, 1750 RPM Curvas de Funcionamiento – 60 Hz, 1750 RPM

FEET PIES

50

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

Model SSH / 9SH Size (Tamaño) 1 x 2-6 RPM 1750 Curve (Curva) CN0620R00 NPSHR – FEET (PIES) A 65⁄8" DIA.

50

4'

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

B 67⁄16"



55

40

5'

56

6' 8'

C 511⁄16"

55 EFF%

3 30 D 5 ⁄8"

20

3

1

A B C D

65⁄8" 67⁄16 511⁄16 53⁄8

¾ ¾ ½ ½

NOTE: Pump will pass a sphere to 1⁄8" diameter. NOTA: La bomba pasará una esfera a 1⁄8" diámetro.

⁄4 HP

⁄2 HP

10

0 0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

10

20

30

40

50

60

70 U.S. GPM 80

CAPACITY (CAPACIDAD) (Q)

FEET PIES

70

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

60

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

Model SSH / 10SH Size (Tamaño) 1 x 2-8 RPM 1750 Curve (Curva) CN0614R00 A 827⁄64" DIA.

4' NPSHR – FEET (PIES) 5'

B 81⁄16"

6'

C 711⁄16"

50

40



42 47

8' 49 EFF%

D 73⁄8" E 71⁄8"

11⁄2 HP

30

3

⁄4 HP

A B C D E

827⁄64" 81⁄16 711⁄16 73⁄8 71⁄8

1½ 1½ 1 ¾ ¾

NOTE: Pump will pass a sphere to 1⁄8" diameter. NOTA: La bomba pasará una esfera a 1⁄8" diámetro.

1 HP

20

10

0 0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

10

20

30

40

50

60

70 U.S. GPM 80

CAPACITY (CAPACIDAD) (Q)

GOULDS PUMPS Commercial Water



Performance Curves – 60 Hz, 1750 RPM Curvas de Funcionamiento – 60 Hz, 1750 RPM Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

Model SSH / 11SH Size (Tamaño) 1 x 2-10 RPM 1750 Curve (Curva) CN0617R00

FEET PIES

120

NPSHR – FEET (PIES)

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

36 3 100 A 10 ⁄32" DIA.



38

8’

14'

12’

43

17'

B 917⁄32" 45

80 C 91⁄8"

1 HP

40

103⁄32" 917⁄32 91⁄8 8¾

3 3 2 2

NOTE: Pump will pass a sphere to 1⁄8" diameter. NOTA: La bomba pasará una esfera a 1⁄8" diámetro.

43 EFF%

D 83⁄4"

60

A B C D

3 HP

2 HP

20

0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0

25

50

75

U.S. GPM 100

CAPACITY (CAPACIDAD) (Q)

METERS METROS

15

Model SSH / 4SH Size (Tamaño) 11⁄2 x 21⁄2- 6 RPM 1750 Curve (Curva) CN0489R01

FEET PIES

4' NPSHR – FEET (PIES) 54

A 6 ⁄4" DIA. 3

6'

59 60

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

40 B 63⁄8"

61



62

C 61⁄16" 62 8'

10 30



D 55⁄8"



61 60 EFF%

E 55⁄16"



11 20 F 4 3 ⁄16"

G 4 ⁄8" H 43⁄16"

5

3

10

0

0 0 0

1

6¾" 63⁄8 61⁄16 55⁄8 55⁄16

1 1 1 ¾ ¾

F G H J

411⁄16 43⁄8 43⁄16 33⁄8

½ ½ ½ ½

NOTE: Pump will pass a sphere to 3⁄16" diameter. NOTA: La bomba pasará una esfera a 3⁄16" diámetro.

1 HP

J 37⁄8"

A B C D E

⁄4 HP

⁄2 HP

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

20 5

40

60 10

80 15

100 20

120 25

U.S. GPM

30 m3⁄ hr

CAPACITY (CAPACIDAD) (Q)

GOULDS PUMPS Commercial Water

10

Performance Curves – 60 Hz, 1750 RPM Curvas de Funcionamiento – 60 Hz, 1750 RPM

METERS METROS

Model SSH / 7SH Size (Tamaño) 11⁄2 x 21⁄2-8 RPM 1750 Curve (Curva) CN0492R00

FEET PIES

6' NPSHR – FEET (PIES)

A 81⁄4" DIA.

38

20 TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia A 8¼" 2 B 713⁄16 2 C 7 1½ D 6¾ 1½ E 67⁄16 1 F 61⁄8 1

48

60

B 713⁄16"

53

54 55

8' 56 57 10'

C 7"

15

13'

D 63⁄4"

57

E 67⁄16"

40 F 61⁄8"

56

NOTE: Pump will pass a sphere to 3⁄16" diameter. NOTA: La bomba pasará una esfera a 3⁄16" diámetro.

55 EFF%

2 HP

10

11⁄2 HP

20

1 HP

5

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0

0 0

20

0

40

5

60

80

10

15

100 20

120 25

U.S. GPM

30

m3⁄ hr

CAPACITY (CAPACIDAD) (Q)

METERS METROS

Model SSH / 5SH Size (Tamaño) 2 x 21⁄2-6 RPM 1750 Curve (Curva) CN0495R00

FEET PIES

A 67⁄8" DIA.

48

4' NPSHR – FEET (PIES) 58

7 40 B 6 ⁄16"

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

63 7' 65 66 67

C 513⁄16"

10 30

9'

D 51⁄2"

67 12' 66

E 51⁄8"



65 EFF%

F 413⁄16"

20 5



2 HP

G 47⁄16" H 41⁄4"

11⁄2 HP

A B C D E

67⁄8" 67⁄16 513⁄16 5½ 51⁄8

2 2 1½ 1½ 1

F G H

413⁄16 47⁄16 4¼

1 ¾ ¾

NOTE: Pump will pass a sphere to 5⁄32" diameter. NOTA: La bomba pasará una esfera a 5⁄32" diámetro.

1 HP

10

0

0 0 0

⁄ HP

34

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

40 10

80

120 20

160 30

200 40

U.S. GPM

50

m3⁄ hr

CAPACITY (CAPACIDAD) (Q)

GOULDS PUMPS Commercial Water

11

Performance Curves – 60 Hz, 1750 RPM Curvas de Funcionamiento – 60 Hz, 1750 RPM

METERS METROS

Model SSH / 8SH Size (Tamaño) 2 x 21⁄2-8 RPM 1750 Curve (Curva) CN0498R01

FEET PIES

A 81⁄4" DIA.

20

48

58

B 73⁄4"

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

60 C 71⁄2"

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

5' NPSHR – FEET (PIES) 67 63 7' 69

D 73⁄16"

15



9'

7 50 E 6 ⁄8"

11' 69



F 63⁄16"

67 EFF%



40 10

8¼" 7¾ 7½ 73⁄16 67⁄8 63⁄16

3 3 2 2 1½ 1½

NOTE: Pump will pass a sphere to 5⁄32" diameter. NOTA: La bomba pasará una esfera a 5⁄32" diámetro.

3 HP

30 2 HP

11⁄2 HP

20

A B C D E F

5 10 NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0

0 0

40

0

80

10

120 20

160

200

30

40

U.S. GPM

50

m3⁄ hr

CAPACITY (CAPACIDAD) (Q)

METERS METROS

Model SSH / 6SH Size (Tamaño) 21⁄2 x 3-6 RPM 1750 Curve (Curva) CN0502R00

FEET PIES

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

20 4' NPSHR – FEET (PIES)

60 TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

57 A 75⁄16" DIA.

15

62

50 B 71⁄8"

5' 67 67

C 6 ⁄16" 15

7' 65

D 611⁄16"

9'

40 E 6 ⁄8" 3

63

F 61⁄16"

10



A B C D E

75⁄16" 71⁄8 615⁄16 611⁄16 63⁄8

3 3 3 3 2



F G

61⁄16 55⁄8

2 1½



11' 15' 62

30 G 55⁄8"

NOTE: Pump will pass a sphere to 5⁄16" diameter. NOTA: La bomba pasará una esfera a 5⁄16" diámetro.

19' 60 57 EFF%

20 5

3 HP

10

0

2 HP 11⁄2 HP

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0 0 0

100 25

200

300 50

U.S. GPM 400

75

m3⁄ hr

CAPACITY (CAPACIDAD) (Q)

GOULDS PUMPS Commercial Water

12

Performance Curves – 50 Hz, 2900 RPM Curvas de Funcionamiento – 50 Hz, 2900 RPM

FEET PIES

120

Model SSH / 9SH Size (Tamaño) 1 x 2-6 RPM 2900 Curve (Curva) CN0621R00 50

40

A 65⁄8" DIA.

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

4'

B 67⁄16"

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

100

55



5' NPSHR – FEET (PIES) 56 7'

C 5 ⁄16" 11

80 D 53⁄8"

55 EFF%

A B C D

65⁄8" 67⁄16 511⁄16 53⁄8

3 3 2 2

NOTE: Pump will pass a sphere to 1⁄8" diameter. NOTA: La bomba pasará una esfera a 1⁄8" diámetro.

60 3 HP

40 1

2 HP

⁄2 HP

20

0 0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

20

40

60

80

100

U.S. GPM 120

CAPACITY (CAPACIDAD) (Q)

FEET PIES

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

250

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

Model SSH / 10SH Size (Tamaño) 1 x 2-8 RPM 2900 Curve (Curva) CN0615R00

5' NPSHR – FEET (PIES)

200

42

7'

A 83⁄8" DIA.

47

B 81⁄16"

150



9’

12’

C 75⁄8"

A B C D E

83⁄8" 81⁄16 75⁄8 71⁄8 71⁄8

5 5 5 5 3

NOTE: Pump will pass a sphere to 1⁄8" diameter. NOTA: La bomba pasará una esfera a 1⁄8" diámetro.

49 EFF%

D 75⁄16" E 71⁄8"

100

5 HP 3 HP

50

0 0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

25

50

75

100

125

U.S. GPM 150

CAPACITY (CAPACIDAD) (Q)

GOULDS PUMPS Commercial Water

13

Performance Curves – 50 Hz, 2900 RPM Curvas de Funcionamiento – 50 Hz, 2900 RPM

300

30

A 103⁄32" DIA. TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

Model SSH / 11SH Size (Tamaño) 1 x 2-10 RPM 2900 Curve (Curva) CN0618R00

FEET PIES

NPSHR – FEET (PIES) 8’

250



18'

38 14’

B 917⁄32"

20'

43

45

C 91⁄8"

103⁄32" 917⁄32 91⁄8 8¾

15 10 10 7½

NOTE: Pump will pass a sphere to 1⁄8" diameter. NOTA: La bomba pasará una esfera a 1⁄8" diámetro.

43 EFF%

200

A B C D

D 83⁄4"

150 10 HP

100

50

71⁄2 HP NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0

25

50

75

100

125

150

U.S. GPM 175

CAPACITY (CAPACIDAD) (Q)

METERS METROS

Model SSH / 4SH Size (Tamaño) 11⁄2 x 21⁄2-6 RPM 2900 Curve (Curva) CN0490R01

FEET PIES

4' NPSHR – FEET (PIES)

40

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

120

55

A 63⁄4" DIA.

6'

60 61

B 63⁄8"

30

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia 62



64

100 C 61⁄16" 64 8' D 55⁄8"

80





62 61 EFF%

E 5 ⁄16" 5



20 60

10



F 411⁄16" G 43⁄8" H 43⁄16" 3 HP

0

F G H J

411⁄16 43⁄8 43⁄16 33⁄8

2 2 1½ 1

1 HP

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0 0

5 5 5 3 3

2 HP

20

0

6¾" 63⁄8 61⁄16 55⁄8 55⁄16

NOTE: Pump will pass a sphere to 3⁄16" diameter. NOTA: La bomba pasará una esfera a 3⁄16" diámetro.

5 HP

40 J 37⁄8"

A B C D E

40 10

80

120 20

160 30

200 40

U.S. GPM

50 m3⁄ hr

CAPACITY (CAPACIDAD) (Q)

GOULDS PUMPS Commercial Water

14

Performance Curves – 50 Hz, 2900 RPM Curvas de Funcionamiento – 50 Hz, 2900 RPM

METERS METROS

60

Model SSH / 7SH Size (Tamaño) 11⁄2 x 21⁄2- 8 RPM 2900 Curve (Curva) CN0493R00

FEET PIES

200 A 81⁄4" DIA.

39

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

6' NPSHR – FEET (PIES)

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

49

50

B 713⁄16"

54

160

55 56

57 58 13'

C 7"

40



8'



17'

D 63⁄4"

120 E 6 ⁄16"

58

7

F 61⁄8"



57

30

8¼" 713⁄16 7 6¾ 67⁄16 61⁄8

10 7½ 7½ 7½ 5 5

NOTE: Pump will pass a sphere to 3⁄16" diameter. NOTA: La bomba pasará una esfera a 3⁄16" diámetro.

56 EFF% 10 HP

71⁄2 HP

80

A B C D E F

20 5 HP

10

0

40

0 0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

40

0

80

10

120

160

20

200

30

U.S. GPM

40

50

m3⁄ hr

CAPACITY (CAPACIDAD) (Q)

METERS METROS

40

49

A 67⁄8" DIA.

5' NPSHR – FEET (PIES) 59

120 TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

Model SSH / 5SH Size (Tamaño) 2 x 21⁄2-6 RPM 2900 Curve (Curva) CN0496R01

FEET PIES



64 7'

B 67⁄16"

66 67

30

100

68

10'

C 5 ⁄16" 13

80



68 14' 67

D 51⁄2"

66 EFF%

E 51⁄8"

20 60

10 HP

F 413⁄16" G 4 ⁄16" 7

71⁄2 HP

H 41⁄4"

40



A B C D E

67⁄8" 67⁄16 513⁄16 5½ 51⁄8

10 7½ 7½ 5 5

F G H

413⁄16 47⁄16 4¼

3 3 3

NOTE: Pump will pass a sphere to 5⁄32" diameter. NOTA: La bomba pasará una esfera a 5⁄32" diámetro.

5 HP

10 20

0

0 0 0

3 HP NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

40 10

80 20

120

160 30

200 40

240 50

280 60

320 70

360 U.S. GPM 80

m3⁄ hr

CAPACITY (CAPACIDAD) (Q)

GOULDS PUMPS Commercial Water

15

Performance Curves – 50 Hz, 2900 RPM Curvas de Funcionamiento – 50 Hz, 2900 RPM

METERS METROS

Model SSH / 8SH Size (Tamaño) 2 x 21⁄2-8 RPM 2900 Curve (Curva) CN0499R01

FEET PIES

6' NPSHR – FEET (PIES)

A 81⁄4" DIA.

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

50

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

49

B 73⁄4"

59

7'

64

1 160 C 7 ⁄2"



68

D 73⁄16"

70

9'

E 67⁄8"

13'

71

40



70

120 F 63⁄16"

16'



68

30

64 EFF% 15 HP

80

A B C D E F

8¼" 7¾ 7½ 73⁄16 67⁄8 63⁄16

15 15 10 10 7½ 7½

NOTE: Pump will pass a sphere to 5⁄32" diameter. NOTA: La bomba pasará una esfera a 5⁄32" diámetro.

20 10 HP

10

40

71⁄2 HP NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0

0 0

40

0

80

10

120

20

160 30

200 40

240 50

280 60

320

360 U.S. GPM

70

80

m3⁄ hr

CAPACITY (CAPACIDAD) (Q)

METERS METROS

FEET PIES

Model SSH / 6SH Size (Tamaño) 21⁄2 x 3-6 RPM 2900 Curve (Curva) CN0501R00 6' NPSHR – FEET (PIES)

175 TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

50

58

150 40

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 75⁄16" DIA.

64

B 71⁄8" C 615⁄16"

7' 69 69

8' 67

125 D 611⁄16"

11'

E 63⁄8"

30

100

65

F 61⁄16"

17'

G 5 ⁄8"

21'

5

62

75

58 EFF%

20 50 10

0

25

0 0 0

A B C D E

75⁄16" 71⁄8 615⁄16 611⁄16 63⁄8

15 15 15 10 10



F G

61⁄16 55⁄8

7½ 7½



13' 64



NOTE: Pump will pass a sphere to 5⁄16" diameter. NOTA: La bomba pasará una esfera a 5⁄16" diámetro.

15 HP 10 HP 71⁄2 HP

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

100 25

200

300 50

400 75

500 100

600 U.S. GPM 125

m3⁄ hr

CAPACITY (CAPACIDAD) (Q)

GOULDS PUMPS Commercial Water

16

Performance Curves – 60 Hz, 3500 RPM Curvas de Funcionamiento – 60 Hz, 3500 RPM

METERS METROS

Model SSH – 24SH / Size (Tamaño) 11⁄2 x 21⁄2-10 RPM 3500 Curve (Curva) CN0503R00

FEET PIES

450

130

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

120 110

50% EFF 55

B 9 ⁄2" 1

350

8'

57

D 87⁄8"

90

300 E 89⁄16"

60 12'

59

55

F 81⁄4"

250

70 60 50 40 30 20 10



10'

59

C 93⁄16"

100

80

6' NPSHR – FEET (PIES)

A 97⁄8" DIA.

400

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

30

200

25 20

150

A B C D E F

97⁄8" 9½ 93⁄16 87⁄8 89⁄16 8¼

30 30 25 25 20 20

NOTE: Pump will pass a sphere to 5⁄16" diameter.

HP

HP

NOTA: La bomba pasará una esfera a 5⁄16" diámetro.

HP

100 50 0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0

50

100

0

150

200

20

250

40

300 U.S. GPM m3⁄hr

60

CAPACITY (CAPACIDAD) Q

METERS METROS

FEET PIES

450

130

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

120 110

Model SSH – 25SH / Size (Tamaño) 2 x 21⁄2-10 RPM 3500 Curve (Curva) CN0506R00 A 9 ⁄8" DIA.

20 10

9' 63



11'

64

D 813⁄16"

80

30

62

350 C 91⁄8"

E 83⁄16" F 715⁄16" 250 G 711⁄16"

40

60

B 91⁄2"

300

50

55% EFF

400

90

60

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

7' NPSHR – FEET (PIES)

7

100

70

Optional Impeller, Impulsor Opcional

20'

64

63 50 40

200 30

150

25



HP





HP

A B C D E F G

97⁄8" 9½ 91⁄8 813⁄16 83⁄16 715⁄16 711⁄16

50 40 40 30 30 25 25

NOTE: Pump will pass a sphere to ½" diameter.

HP

NOTA: La bomba pasará una esfera a ½" diámetro.

HP

100 50 0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0 0

50

100 20

150

200 40

250

300 60

350 80

400

450 100

500 U.S. GPM m3⁄hr

CAPACITY (CAPACIDAD) Q

GOULDS PUMPS Commercial Water

17

Performance Curves – 60 Hz, 3500 RPM Curvas de Funcionamiento – 60 Hz, 3500 RPM

METERS METROS

Model SSH – 22SH / Size (Tamaño) 21⁄2 x 3-8 RPM 3500 Curve (Curva) CN0509R00

FEET PIES

40% EFF

350

90

70 60 50

12' 15'

68 70

D 81⁄4"

275 80

10'

65

C 81⁄2"

300

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia 20'

25'

68 30'

65

7 250 E 7 ⁄8"

60 71

1 225 F 7 ⁄2"

200 G 7 ⁄8" 1

11 175 H 6 ⁄16"

60

J 61⁄2"

150

100 75 50

91⁄16"

60



B



50



C



50



D



40



E

77⁄8

40



F



30



G

71⁄8

25



H

6 ⁄16

20



J



20

11

NOTA: La bomba pasará una esfera a 19⁄32" diámetro.

25

0

100

0

20

200

300

40

400

60

500

80

30

HP 20 HP

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

100

HP

20

HP

A

40

30

15

125

HP

40



NOTE: Pump will pass a sphere to 19⁄32" diameter.

HP

50

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

100

A 91⁄16" DIA. 3 325 B 8 ⁄4"

(PIES) 7' NPSHR – FEET 8' 50 60

Optional Impeller, Impulsor Opcional

HP

600

120

700

140

800

160

180

U.S. GPM m3⁄hr

CAPACITY (CAPACIDAD) Q

METERS METROS

Model SSH – 27SH / Size (Tamaño) 21⁄2 x 3-10 RPM 3500 Curve (Curva) CN0512R00

FEET PIES

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

600 175

7' NPSHR – FEET (PIES)

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

550 150

500

45% EFF

55

8' 60

10' 12'

65

A 10 ⁄8" DIA. 3

125

15'

69

450 B 915⁄16"

20' 70

9 400 C 9 ⁄16"

30'

69

D 9 ⁄4" 1

100

350

10

E 83⁄4"

300 75

40

250

HP

25

60 50

150

103⁄8"

100

B

915⁄16

75



C

9 ⁄16

75



D



60



E



50

9

NOTA: La bomba pasará una esfera a 19⁄32" diámetro.

HP

HP

100 50

0

A



NOTE: Pump will pass a sphere to 19⁄32" diameter.

P

75 H 65 P

200 50

0H



0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0

100

0

20

200 40

300 60

400 80

500 100

120

600 140

700

800

U.S. GPM

160

180

m3⁄hr

CAPACITY (CAPACIDAD) Q

GOULDS PUMPS Commercial Water

18

Performance Curves – 60 Hz, 3500 RPM Curvas de Funcionamiento – 60 Hz, 3500 RPM

METERS METROS

FEET PIES

10' 50% EFF

350

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

100 90 80 70 60 50

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Model SSH – 23SH / Size (Tamaño) 3 x 4-8 RPM 3500 Curve (Curva) CN0515R00

70

325

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

12' NPSHR – FEET (PIES) 60 14'

A 91⁄16" DIA. B 811⁄16"

17'

75

77

300 C 8 ⁄16" 7

20' 78

275 D 81⁄16"

78 25' 77

30'

250 E 711⁄16"

30 20

0H

P

G 71⁄8"

200

75

H 67⁄8"

175

J 61⁄2"

60

150 40

10

75

F 71⁄2"

225

70 50

125 K 6" 100

40

L 51⁄2"

75 50

15

0

200

0

40

400 80

600 120

HP

HP



A

91⁄16"



B

811⁄16

75



C

87⁄16

60



D

81⁄16

50



E

7 ⁄16

50



F



40



G

71⁄8

40



H

67⁄8

30



J



25



K

6

20



L



15

11

75

NOTE: Pump will pass a sphere to ¾" diameter. NOTA: La bomba pasará una esfera a ¾" diámetro.

HP

1000

200

HP

HP

3 25 0 HP H 20 HP P

800 160

Optional Impeller, Impulsor Opcional

1200

240

1400

280

320

1600 360

U.S. GPM m3⁄hr

CAPACITY (CAPACIDAD) Q

METERS METROS

Model SSH – 28SH / Size (Tamaño) 3 x 4-10 RPM 3500 Curve (Curva) CN0518R00

FEET PIES

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

600

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

175

150

125

100

550 NPSHR – FEET (PIES) 500 8' 10' 45% EFF 55 65 450 70 C 913⁄16" DIA.

400

75

25

25' 75

250

60

73

913⁄16" 97⁄16 91⁄16 811⁄16

100 100 75 75

NOTA: La bomba pasará una esfera a ¾" diámetro.

30'

10 HP

C D E F

NOTE: Pump will pass a sphere to ¾" diameter.

20' 76

F 811⁄16"

75

0H

P

HP

150 100 50

0

17' 76

350 E 91⁄16"

200 50

14'

73

D 97⁄16"

300 75

12'



0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0 0

200 40

400 80

600 120

800 160

1000 200

240

1200 280

1400 320

1600 360

U.S. GPM m3⁄hr

CAPACITY (CAPACIDAD) Q

GOULDS PUMPS Commercial Water

19

Performance Curves – 60 Hz, 1750 RPM Curvas de Funcionamiento – 60 Hz, 1750 RPM

METERS METROS

Model SSH – 24SH / Size (Tamaño) 11⁄2 x 21⁄2-10 RPM 1750 Curve (Curva) CN0505R00

FEET PIES

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

110

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

30

3' NPSHR – FEET (PIES)

A 97⁄8" DIA.

100

45% EFF 50



A

97⁄8"

5



B



5



C

93⁄16

3



D

87⁄8

3



E

89⁄16

3

60



F



2

50

NOTE: Pump will pass a sphere to 5⁄16" diameter.

1 90 B 9 ⁄2"

25

52

4'

54

C 93⁄16"

56

7 80 D 8 ⁄8"

54

E 8 ⁄16" 9

20

15

70 F 81⁄4"

5

52 50

3H

40 10

5'

2H

P

NOTA: La bomba pasará una esfera a 5⁄16" diámetro.

P

30 20 10 0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0

10

20

0

30

40

5

50

60

10

70

80

90

15

100

20

110

120

25

130

140

150 U.S. GPM m3⁄hr

30

CAPACITY (CAPACIDAD) Q

METERS METROS

110

A 9 ⁄8" DIA.

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

100

25

20

15

55

B 91⁄2"

90

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

4' NPSHR – FEET (PIES) 50% EFF

7

30

Optional Impeller, Impulsor Opcional

Model SSH – 25SH / Size (Tamaño) 2 x 21⁄2-10 RPM 1750 Curve (Curva) CN0508R00

FEET PIES

57

58

5'

59

C 9 ⁄8 " 1

13 80 D 8 ⁄16"

59

8' 58

70 E 83⁄16"

7.5

HP

F 715⁄16" 60 G 711⁄16" 5H P

50

5

A

97⁄8"





B



5



C

91⁄8

5



D

813⁄16

5



E

83⁄16

3



F

715⁄16

3



G

7 ⁄16

3

11

NOTE: Pump will pass a sphere to ½" diameter.

40 10



30

NOTA: La bomba pasará una esfera a ½" diámetro.

3H P

20 10 0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0

20

0

5

40

60

10

100

80 15

20

120 25

140 30

160 35

180 40

200

220

45

50

240 55

U.S. GPM m3⁄hr

CAPACITY (CAPACIDAD) Q

GOULDS PUMPS Commercial Water

20

Performance Curves – 60 Hz, 1725 RPM Curvas de Funcionamiento – 60 Hz, 1725 RPM

METERS METROS

Model SSH – 22SH / Size (Tamaño) 21⁄2 x 3-8 RPM 1750 Curve (Curva) CN0511R00

FEET PIES

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

120

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

35

30

110



100 90

25

40% EFF

5' 50

NPSHR – FEET (PIES) 6'

55

80 A 9 ⁄16" DIA.

60

1

8'

62

C 8 ⁄2"

70

64

D 81⁄4"

10'

62

60 E 7 ⁄8"

60

7

15

50

15'

55





C







D



5



E

77⁄8

5



G

71⁄8

3

NOTA: La bomba pasará una esfera a 19⁄32" diámetro.

50

G 7 ⁄8" 1

91⁄16"

H 611⁄16 3 NOTE: Pump will pass a sphere to 19⁄32" diameter.

1

20

A

40 H 611⁄16" 10

5

2H

30

71 ⁄2 H

20 5H

10 0

P

3H

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0

0

50

0

10

100 20

150 30

200

250

40

50

300 60

P

P

350

70

P

400

80

450 U.S. GPM

90

100

m3⁄hr

CAPACITY (CAPACIDAD) Q

METERS METROS

Model SSH – 27SH / Size (Tamaño) 21⁄2 x 3-10 RPM 1750 Curve (Curva) CN0514R00

FEET PIES

50% EFF

120

3

110 100

63

A 103⁄8" DIA.

5' 66 68

B 915⁄16"

7' 68

10' 15'

66

D 9 ⁄4" 1

20'

63

80

E 83⁄4"

60

70 60 HP

15

50

A

103⁄8"

15



B

915⁄16

10



C

99⁄16

10



D







E





NOTA: La bomba pasará una esfera a 19⁄32" diámetro.

HP

55



NOTE: Pump will pass a sphere to 19⁄32" diameter.

15

2

NPSHR – FEET (PIES)

60

C 99⁄16"

90 2

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

5 10



1 2

HP

5

HP

40 10

7

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

3

55

Optional Impeller, Impulsor Opcional

30 20 10

0

0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0 0

50 10

100 20

150 30

200 40

250 50

300 60

70

350 80

400 90

450 U.S. GPM 100

m3⁄hr

CAPACITY (CAPACIDAD) Q

GOULDS PUMPS Commercial Water

21

Performance Curves – 60 Hz, 1725 RPM Curvas de Funcionamiento – 60 Hz, 1725 RPM

METERS METROS

Model SSH – 23SH / Size (Tamaño) 3 x 4-8 RPM 1750 Curve (Curva) CN0517R00

FEET PIES

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

120

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

35

30

110



A

91⁄16"

10

100



C

87⁄16





D

81⁄16





F



5



G

71⁄8

5

45% EFF

90 25

20

55

1 80 A 9 ⁄16" DIA.

5

8'

73

15' 73

F 71⁄2"

50

NOTA: La bomba pasará una esfera a ½" diámetro.

71 68

G 71⁄8"

65

J 61⁄2"

55

30 3

20

71 ⁄2 H

HP

5H

10 0

J 6½ 3 NOTE: Pump will pass a sphere to ½" diameter.

10'

74

D 8 ⁄16" 1

40 10

5' NPSHR – FEET (PIES) 68 6' 71

70 C 87⁄16" 60

15

65

0

0

100

0

20

200 40

300 60

400 80

500 100

600

120

10

HP

P

P

700

140

800

160

900 U.S. GPM

180

200

m3⁄hr

CAPACITY (CAPACIDAD) Q

FEET PIES

40

130

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

METERS METROS

35

30

Model SSH – 28SH / Size (Tamaño) 3 x 4-10 RPM 1750 Curve (Curva) CN0520R00

45% EFF 55

65

120 A 105⁄8" DIA.

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

7' NPSHR – FEET (PIES) 70 73

110 B 101⁄4"

8' 10'

100 C 913⁄16"

74

25

20

10

20

50

15

30 20

20



B

10¼

15



C

913⁄16

15



D

97⁄16

15

NOTA: La bomba pasará una esfera a ¾" diámetro.

30'

HP

40 10

105⁄8"

65

70 60

15

20' 70

80

A

NOTE: Pump will pass a sphere to ¾" diameter.

15' 73

7 90 D 9 ⁄16"



HP

HP

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0 0

100 20

200 40

300 60

400 80

500 100

120

600 140

700 160

800 180

900 U.S. GPM 200

m3⁄hr

CAPACITY (CAPACIDAD) Q

GOULDS PUMPS Commercial Water

22

Performance Curves – 50 Hz, 2900 RPM Curvas de Funcionamiento – 50 Hz, 2900 RPM

METERS METROS

90

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

80

Model SSH – 24SH / Size (Tamaño) 11⁄2 x 21⁄2-10 RPM 2900 Curve (Curva) CN0504R00

FEET PIES

300

50

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

3' NPSHR – FEET (PIES)

A 97⁄8" DIA.

48% EFF 53

250 B 91⁄2"

6'

55

A 97⁄8" 20 B 9½ 15 C 93⁄16 15 D 87⁄8 15 9 E 8 ⁄ 10 16 F 8¼ 10 NOTE: Pump will pass a sphere to ½" diameter.

58

D 87⁄8"

57

9 200 E 8 ⁄16"

10' 55

53

F 81⁄4"

20

HP

150 15

40 30



8'

57

C 93⁄16"

70 60

Optional Impeller, Impulsor Opcional

100

10

HP

NOTA: La bomba pasará una esfera a ½" diámetro.

HP

20 50 10 0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0

20

0

40

60

80

10

100

120

20

140

160

30

180

200

220

40

240

U.S. GPM m3⁄hr

50

CAPACITY (CAPACIDAD) Q

METERS METROS

90

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

80

FEET PIES

300

250

50

Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

6' NPSHR – FEET (PIES) 53% EFF

A 97⁄8" DIA.

58

B 91⁄2"

60

8' 61 62

C 9 ⁄8" 1

70 60

Model SSH – 25SH / Size (Tamaño) 2 x 21⁄2-10 RPM 2900 Curve (Curva) CN0507R00



10'

D 813⁄16"

200

62

E 83⁄16" F 715⁄16" G 711⁄16"

30

B



25



C

91⁄8

20

61



D

813⁄16

20



E

83⁄16

15



F

715⁄16

15



G

7 ⁄16

15

20 15

100

30



30

40

97⁄8"

17'

25

150

A

HP

HP

11

NOTE: Pump will pass a sphere to 5⁄16" diameter.

HP

HP

NOTA: La bomba pasará una esfera a 5⁄16" diámetro.

20 50 10 NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0

0 0

40

80 20

120

160

200

240

40

280 60

320

360 80

400

U.S. GPM m3⁄hr

CAPACITY (CAPACIDAD) Q

GOULDS PUMPS Commercial Water

23

Performance Curves – 50 Hz, 2900 RPM Curvas de Funcionamiento – 50 Hz, 2900 RPM METERS METROS

Model SSH – 22SH / Size (Tamaño) 21⁄2 x 3-8 RPM 2900 Curve (Curva) CN0510R00

FEET PIES

250

40% EFF

70

50

A 91⁄16" DIA.

Optional Impeller, Impulsor Opcional

6' NPSHR – FEET (PIES) 7' 8' 60

10'

225 B 83⁄4"

50

65

C 81⁄2"

200

12'

67

D 81⁄4"

15' 18'

65

68

F 71⁄2"

150 40

20'

60

175 E 77⁄8"

40

G 71⁄8"

125 H 611⁄16" 30

100

50 25

HP

20

HP

J 61⁄2"

10

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

60

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

75

20

50 10 0

15

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0

100

0

20

200

300

40

60

400 80

A

91⁄16"

40



B



30



C



30



D



25



E

77⁄8

20



F



20



G

71⁄8

15



H

6 ⁄16

15



J



15

11

NOTE: Pump will pass a sphere to 19⁄32" diameter.

HP

NOTA: La bomba pasará una esfera a 19⁄32" diámetro.

HP

HP

HP

500 100

30



600 120

140

U.S. GPM 700 m3⁄hr

CAPACITY (CAPACIDAD) Q

METERS METROS

Model SSH – 27SH / Size (Tamaño) 21⁄2 x 3-10 RPM 2900 Curve (Curva) CN0513R00

FEET PIES

400

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

6'

55

100

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

NPSHR – FEET (PIES)

45% EFF

350

Optional Impeller, Impulsor Opcional

8'

60

10'

65

A 103⁄8" DIA.

68

300 B 915⁄16"

12' 15' 69

C 99⁄16"

75

20'

68

65

250 D 91⁄4" E 83⁄4"

50

200 25

50

HP

40

150 30

100



A

103⁄8"



B

9 ⁄16

40



C

9 9⁄16

40



D



30



E



30

15

50

NOTE: Pump will pass a sphere to 19⁄32" diameter.

HP

NOTA: La bomba pasará una esfera a 19⁄32" diámetro.

HP

HP

25 50

0

0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0 0

100 20

200 40

300 60

400 80

500 100

600 120

140

U.S. GPM 700 m3⁄hr

CAPACITY (CAPACIDAD) Q

GOULDS PUMPS Commercial Water

24

Performance Curves – 50 Hz, 2900 RPM Curvas de Funcionamiento – 50 Hz, 2900 RPM

METERS METROS

Model SSH – 23SH / Size (Tamaño) 3 x 4-8 RPM 2900 Curve (Curva) CN0516R00

FEET PIES

250

50% EFF

70

60

A 91⁄16" DIA.

9'

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

12' 72

70

B 811⁄16" C 87⁄16"

200

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

10' NPSHR – FEET (PIES)

225 60

Optional Impeller, Impulsor Opcional

15'

74

76 D 81⁄16"

50

20'

76 74

175

E 711⁄16"

72

F 71⁄2"

150

50

G 71⁄8"

40

125 H 6 ⁄8"

HP

30

40

70

20

HP

75

25 20

50

15

10 0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0

200

0

400

40

600

80

120

91⁄16"



B

811⁄16

50 40



C

87⁄16

40



D

81⁄16

30



E

711⁄16

30



F



25



G

71⁄8

20



H

67⁄8

20

NOTA: La bomba pasará una esfera a ½" diámetro.

100 30

A

J 6½ 15 NOTE: Pump will pass a sphere to ½" diameter.

7

J 61⁄2"



HP

HP

HP

HP

800 160

1000 200

1200 240

280

U.S. GPM 1400 m3⁄hr

CAPACITY (CAPACIDAD) Q

METERS METROS

Model SSH – 28SH / Size (Tamaño) 3 x 4-10 RPM 2900 Curve (Curva) CN0519R00

FEET PIES

400

350

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

50% EFF

300

8' 60

9' 65

C 9 ⁄16" DIA. 13

10' 70

12'

14'

73

17'

75

D 97⁄16"

250

75

E 91⁄16"

73

F 811⁄16"

200 50

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

NPSHR – FEET (PIES)

100

75

Optional Impeller, Impulsor Opcional

30

150

HP 40

50 HP

C

913⁄16"

60



D

9 ⁄16

50



E

91⁄16

50



F

811⁄16

40

7

NOTE: Pump will pass a sphere to ¾" diameter.

20'

60



NOTA: La bomba pasará una esfera a ¾" diámetro. HP

HP

100 25 50

0

0

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

0 0

200 40

400 80

600 120

800 160

1000 200

1200 240

280

U.S. GPM 1400 m3⁄hr

CAPACITY (CAPACIDAD) Q

GOULDS PUMPS Commercial Water

25

SSH Close Coupled – Materials of Construction SSH Acople Cerrado – Materiales de Construcción 101

100

178

108

101

100

370

103

SSH Frame Mounted – Materials of Construction SSH Armazón Montado – Materiales de Construcción 513

370

228

383 108

184

412A

513

134 184

370C 333A

412A

383

199 422 408 412F 126 Item No., Description, Parte No. Descripción

371

103 Materials, Materiales

199 422 408 178 412F Item No., Description, Parte No. Descripción

126

370B

123

168 112

382

122

Materials, Materiales

100

Casing, Carcasa

100

Casing, Carcasa

101

Impeller, Impulsor

101

Impeller, Impulsor

103

Wear ring, Anillo de desgaste

103

Wear ring, Anillo de desgaste

184

Seal housing, Alojamiento del sello

184

Seal housing, Alojamiento del sello

126

Shaft sleeve, Camisa del eje

316 SS, 316 acero inox.

126

Shaft sleeve, Camisa del eje

316 SS, 316 acero inox.

422

Impeller stud, Perno del impulsor

Steel, Acero

178

Impeller key, Llave del impulsor

178

Impeller key, Llave del impulsor

Carbon steel, Acero al carbono

422

Impeller Stud, Perno del impulsor

Carbon steel, Acero al carbono

199

Impeller washer, Arandela del impulsor

316 SS, 316 acero inox.

199

Impeller washer, Arandela del impulsor

316 SS, 316 acero inox.

370

370

Casing bolt with nut (casing to adapter), 316L SS, Tornillo de la carcasa con tuerca 316L acero inoxidable (carcasa para adaptador)

408

Casing bolt with nut, Tornillo de la carcasa con tuerca 316L SS, Drain plug – 3⁄8 NPT, Válvula de drenaje – 3⁄8 NPT 316L acero inox.

513

O-ring, Anillo ‘O’

Viton

Cast iron ASTM A48 CL20, Hierro fundido ASTM A48CL20

383

Mechanical seal, Sello mecánico

See seal chart, Ver tabla del sello

108

Adapter, Adaptador

Steel SAE 1200 series, Acero SAE series 1200

228

Bearing frame, Armazón de balineras

134

Bearing cover, Cubierta de balineras

122

Pump shaft, Eje de la bomba

Cast iron ASTM A48CL20, Hierro fundido ASTM A48CL20 Carbon steel, Acero al carbono

168

Ball bearing (inboard), Balineras de bolas (interior)

112

Ball bearing (outboard), Balineras de bolas (exterior)

382

Retaining ring, Anillo de sujeción

108 Adapter, Adaptador 371

Hex head cap screw (adapter to motor), Tornillo de cabeza hexagonal (adaptador para motor)

316L SS, 316L acero inox.

412A O-ring, Impeller, Anillo en O, impulsor 412F

O-ring, shaft sleeve, Anillo en O, camisa del eje

513

O-ring, Anillo 'O'

408

Drain plug – 3⁄8 NPT, Válvula de drenaje – 3⁄8 NPT

316L SS, 316 acero inoxidable

383

Mechanical seal, Sello mecánico

See seal chart, Ver tabla del sello

Viton

Mechanical Seal, Sello Mecánico John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Part No., Metal Intended Pleza Número Item, Rotary, Stationary, Elastomers, Parts, Duty, 180-210 250-360 Parte Rotativo Estacionario Elastómeros Partes Servicio Frames, Frames, Metálicas Propuesto Armazones Armazones

316L SS, 316L acero inox.

Hex head cap screw (adapter to bearing frame), 370B Tornillo de cabeza hexagonal Steel, Acero (adaptador para armazón de balineras) Hex head cap screw (bearing frame to cover), 370C Tornillo de cabeza hexagonal (armazón de balineras para cubierta) 333A Lip seal, Sello cubierto

BUNA-N

193

*Grease fitting, Accesorio de grasa

Steel, Acero

123

V-ring deflector, Deflector anillo ‘V’

BUNA-N

* M-Group only

Hot Water, 10K19 10K20 EPR 383 Carbon, Silicon 316 SS, Agua Caliente Options, Carbone Carbide, 316 Mild Abrasive, 10K27 10K45 383 Carburo de Acero Abrasivo Suave Viton inoxidable Severe Duty, Opciones silicona 10K64 10K65 Sil-Carb. Deber Severo

GOULDS PUMPS Commercial Water

26

SSH – Engineering Data SSH – Información Técnica

S-Group Grupo-S

Channel Steel Bedplate, Clockwise Rotation Viewed from Drive End; Fundación de Acero, Rotación en Dirección de las Agujas del Reloj Visto desde el Extremo del Motor DISCHARGE DESCARGA

AB MAX.

CP



PRIME PLUG SUCTION SUCCIÓN DC DD MAX.

SINGLE PHASE ONLY, SOLO UNIFÁSICOS

KEYWAY 1⁄8 x ¼ CHAVETERO 1⁄8 x ¼

(4) HOLES 5 P ⁄8 DIA. MAX. (4) AGUJEROS 5 ⁄8 DIA.

HG

DRAIN PLUG HE

SPACER COUPLING ACOPLE DEL ESPACIADOR COUPLING GUARD, GUARDA ACOPLE

3 1.125 Ø 1.124

X

HD

CREF

Z

Y

HE

⁄8" – 19 BSP

3

HA

HL

HP

HF HB

– Determined Dimensions and Weights by Pump, Dimension “HL” Determined Dimensiones y Pesos – Determinados por la Bomba by Pump and Bedplate, Dimensión “HL” determinada la bomba y el motor Motor Frame Size, Tamaño del bastidor del motor Pump, Bomba Suction*, Discharge*, CP DC Max., DD X Y Z Wt. (lbs.), 143/ 183/ 213/ 254/ 284/ Sución* Descarga* DC Máx. Peso (lib.) 145 184 215 256 286 9ASH 1 X 2–6 5 4¾ 63⁄8 56 163⁄8 91⁄8 75⁄8 37⁄8 10ASH 1 X 2–8 2 1 55⁄8 53⁄8 71⁄8 31⁄8 37⁄8 64 11ASH 1 X 2–10 17¼ 67⁄8 65⁄8 87⁄8 86 10 8½ 4¾ 4SH 1½ X 2½–6 16½ 5 4¾ 63⁄8 3¼ 57 9¼ 7¾ 4 1½ 7SH 1½ X 2½–8 55⁄8 53⁄8 1 66 2½ 7 ⁄8 5SH 2 X 2½–6 5 4¾ 35⁄8 57 2 17¼ 4 10 8½ 4¾ 8SH 2 X 2½–8 68 6 5¾ 715⁄16 6SH 2½ X 3–6 3 2½ 59 * For use with ANSI Class 150 mating flanges. * Para usar con bridas que casan ANSI clase 150. Available Motor and Bedplate Dimensions and Weights, Pesos y Dimensiones Disponibles de la Fundación y del Motor

NOTES: 1. All pumps shipped in vertical discharge position. May be rotated in 90° increments. Tighten 3⁄8 – 16 casing bolts to 12 ft./lbs. torque. 2. Dimensions in inches. 3. Motor dimensions may vary with motor manufacturer. 4. Not to be used for construction purposes. NOTAS: 1. Todas las bombas transportadas en posición de descarga vertical. Pueden rotarse en aumentos de 90º. Apretar 3⁄8 – 16 tornillos de carcasa a 12 pies/libras potencia. 2. Las dimensiones en pulgadas. 3. Las dimensiones puede que varíen con los fabricantes.. 4. No para propósitos de construcción.

HP @ 3500 RPM, HP @ 1750 RPM, Motor HP a 3500 RPM HP a 1750 RPM Frame, Armazón Single Phase, Three Phase, Single Phase, Three Phase, Trifásicos Monofásicos Trifásicos del Monofásicos Motor ODP TEFC ODP TEFC ODP TEFC ODP TEFC 143T

1

145T

2

2

2 – 3

2

182T

3

3

5

3

1½ 2

184T

5

5



5

3 or 5

213T

10

215T

Bedplate Data, Datos de la Fundación AB P Wt. Wt. Max., CREF Max., Max., Bearing AB P Peso HA HB HD** HE HF HG HP* (lbs.), Motor Frame Peso Shim Máx. Máx. Máx. (libras) Shim 1 1 1 133⁄8 45 5 5¼ 6 ⁄8 1¾ 1½ 1½ – 2 1½ – 2 14¼ 53 10 28 8 3¾ 24 2¾ ¾ 48 — 2 3 3 165⁄8 74 57⁄8 77⁄8 ¾ 3 5 3 181⁄8 95



15

73⁄8 10

254T

20

15

256T

25

101⁄8 20

13 233⁄8

284TS

30

25

247⁄8

286TS

40

125⁄8 30

18

95⁄8 19 ⁄8

116

1

136

215⁄8

266 13 42 10¼ 5¼ 38½ 4 264 1¾ 392 15 44 10½ 5¾ 40½ 3½ 432

15 26 ⁄8 5

12 31

8¼ 4¼ 29

3

1

65





110



1

124





Dimensions and weights vary with manufacturers. Dimensions in inches and weights in lbs. * “HP” Dimensions at motor end only. ** “HD” Dimension for 254T/256T motor frame on 1 x 2-10 only is 11"; A ¾" motor shim and a 1¾" bearing frame shim are required. Dimensiones y pesos varían con los fabricantes. Dimensiones en pulgadas y pesos en libras. * Dimensiones “HP” sólo en el extremo del motor. ** La dimensión “HD” para el bastidor del motor 254T/256T de 1 x 2 - 10 es sólo 11"; se requieren una cuña del motor de ¾" y una cuña del bastidor de apoyo de 1¾".

GOULDS PUMPS Commercial Water

27

SSH-F – Engineering Data SSH-F – Información Técnica

M-Group Grupo-M

Channel Steel Bedplate, Clockwise Rotation Viewed from Drive End; Fundación de Acero, Rotación en Dirección de las Agujas del Reloj Visto desde el Extremo del Motor C REF.

CP

DISCHARGE

ABMAX.

3 3⁄4

41 5 ⁄ 1 6

Y

SPACER COUPLING

3 7⁄ 8

PRIME PLUG

COUPLING GUARD SINGLE PHASE ONLY

1.625 1.624 SUCTION

PMAX. DC

MAX.

DD

4 HOLES

KEYWAY

5⁄8

3/16 X 3/8

HD

HG

DRAIN PLUG HE

HE HA

HB

NOTE: 1. Pumps will be shipped with top vertical discharge as standard. For other orientations, remove casing bolts, rotate discharge to desired position and tighten 3⁄8 – 16 bolts to 12 ft./lbs. 2. ALL dimensions in inches. 3. Not for construction purposes.

Dimensions and Weights – Determined by Pump, Dimensiones y Pesos – Determinados por la Bomba Wt. DC Pump Size, (lbs.), Max., S uction*, D ischarge*, DD L X Y Tamaño de Pump CP DC Peso Descarga* la Bomba Succión* Máx. (libras) 24SH 1½ x 2½-10 1½ 125 2½ 67⁄8 65⁄8 25SH 2 x 2½-10 2 815⁄16 125 1 23 10 ⁄8 4 22SH 2½ x 3-8 61⁄8 57⁄8 125 3 2½ 27SH 2½ x 3-10 15 134 7 5 6 ⁄8 6 ⁄8 9 ⁄16 23SH 3 x 4-8 136 1 4 3 24 11 ⁄ 8 5 28SH 3 x 4-10 75⁄8 73⁄8 111⁄8 148

NOTA: 1. Las bombas se transportarán con la descarga vertical superior como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 12 pies/libras. 2. TODAS las dimensiones en pulgadas. 3. No para propósitos de construcción.

* For use with ANSI class 150 mating flanges. * Para usar con bridas que casan ANSI clase 150.

Available Motor and Bedplate Dimensions and Weights, Pesos y Dimensiones Disponibles de la Fundación y del Motor Motor HP @ 3500 RPM Frame, Three Phase, Armazón Trifásicos del Motor ODP TEFC

HP @ 1750 RPM – T-Frame Only

184T

AB P Wt. Max., C Max., Max., AB Ref. P Peso HA Máx. Máx. Máx.

Single Phase, Monofásicos

Three Phase, Trifásicos

ODP

TEFC

ODP

TEFC

3 or 5

3

5

5

213T





215T

15

10

73⁄8 10

95⁄8 191⁄8

254T

20

15

15

15

215⁄8

256T

25

20

20

91⁄2 20



13 3 23 ⁄8

284TS/T

30

25

25

25

247⁄8

286TS/T

40

125⁄8 30



324TS/T

50

40



283⁄4

326TS/T 364TS/T 365TS/T

100

57⁄8

Bedplate Data, Datos de la Fundación HF

HG

Wt. (lbs.), Peso (libras)

51⁄4

38½

4

111



40½



124

4

183

4

214

HB

HD

HE

42

101⁄4

392 15 44 10½ 422

181⁄8

77⁄8

95

18



116 136

13

266 264

15 265⁄8

151⁄8 75

187⁄8 325⁄8

12 634 18 48 7¼ 44½ 834 13 1000

100

367⁄8

1060

60

141⁄8 50

173⁄8 30¼

75

60

315⁄8

405TS/T

13 ⁄ 4

HF

L

3/8” 3GAS ⁄8" –THREAD 19 BSP UNI ISO 228/1

18

205⁄8

592

22

56

14



52½

Dimensions and weights vary with manufacturers. Dimensions in inches and weights in lbs. Dimensiones y pesos varían con los fabricantes. Dimensiones en pulgadas y pesos en libras.

GOULDS PUMPS Commercial Water

28

S-Group Grupo-S

SSH Close Coupled – Dimensions and Weights SSH Acople Cerrado – Dimensiones y Pesos (All dimensions in inches and weights in lbs. Do not use for construction purposes.) (Todas las dimensiones en pulgadas y pesos en libras. No usar para propósitos de construcción.)

DISCHARGE DESCARGA

AB MAX.

Y

CREF

Z

PRIME PLUG X SUCTION SUCCIÓN P MAX. G

E

E

D

DC DD MAX.

DRAIN PLUG

A

L 3 ⁄8" – 19 BSP

150 lb. Flange, DC Wt. DIM. “L” (Motor Frame Size) Brida de 150 lib. Max., Pump, (lbs.), DIM. “L” (Tamaño del Armazón del Motor) X Y Z Bomba DC DD Pesos Suct.*, Disch.*, Máx. 143/145 182/184 213/215 254/256 (libras) Succ.* Desc.* 9ASH 1 x 2 – 6 5 4¾ 63⁄8 24 31⁄8 93⁄8 10½ 11½ — 10ASH 1 x 2 – 8 2 1 55⁄8 53⁄8 71⁄8 37⁄8 32 11ASH 1 x 2 – 10 67⁄8 65⁄8 87⁄8 4 10¾ 113⁄8 123⁄8 125⁄8 54 4SH 1½ x 2½ – 6 5 4¾ 63⁄8 3¼ 9¾ 103⁄8 113⁄8 — 25 1½ 7SH 1½ x 2½ – 8 55⁄8 53⁄8 71⁄8 34 2½ 5SH 2 x 2½ – 6 5 4¾ 71⁄8 4 35⁄8 25 2 10½ 111⁄8 121⁄8 123⁄8 8SH 2 x 2½ – 8 5¾ 36 15 6 7 ⁄16 6SH 2½ x 3 – 6 3 2½ 4¾ 27 * For use with ANSI class 150 mating flanges. * Para usar con bridas que casan ANSI clase 150.

Dimensions Determined by JM Motor Frame, Dimensiones Determinadas por el Armazón del Motor JM P Motor Wt. H Max., (lbs.) Dia., D E F G CREF P Peso Motor H (lib.) Diám. Máx. 143JM 2 1 41 6½ 5¼ 6 3½ 2¾ ⁄8 11¼ 11⁄32 65⁄8 145JM 2½ 57 182JM 2¼ 3 77 8½ 67⁄8 6½ 4½ 3¾ ⁄16 13½ 77⁄8 184JM 97 13 2¾ ⁄32 213JM 122 7 9½ 73⁄8 8 5¼ 4¼ ⁄32 15½ 95⁄8 215JM 3½ 155 254TCZ 9½ 41⁄8 265 5 17 11¼ 9 6¼ 5 ¼ 18 ⁄8 ⁄32 11½ 256TCZ 11¾ 5 320

JM Frame, JM A AB B Armazón

F

F

H-(4) HOLES H-(4) AGUJEROS

B

NOTE: 1. Pumps shipped in vertical discharge as standard. For other orientations, remove casing bolts, rotate discharge to desired position, and tighten 3⁄8 – 16 bolts to 12 ft./lbs., 7⁄16 – 14 bolts to 20 ft./lbs. 2. ALL dimensions in inches. 3. Motor dimensions may vary with motor manufacturer. 4. Not for construction purposes. NOTA: 1. Las bombas se transportarán en descarga vertical como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 12 pies/libras, 7⁄16 – 14 tornillos a 20 pies/libras. 2. TODAS las dimensiones en pulgadas. 3. Las dimensiones puede que varíen con los fabricantes. 4. No para propósitos de construcción.

Motor Frame Selections, Selecciones del Armazón del Motor Motor Horsepower, Potencia del Motor Motor Frame, 3500 RPM, 3500 RPM 1750 RPM, 1750 RPM Armazón 1Ø, Monofásicos 3Ø, Trifásicos 1Ø, Monofásicos 3Ø, Trifásicos del Motor ODP TEFC ODP TEFC ODP TEFC ODP TEFC 143JM – – – – – – 1 1 145JM 2 2 2-3 2 1-1½ 1-1½ 1½-2 1½-2 182JM 3 3 5 3 2 2-3 3 3 184JM 5 5 7½ 5 3 – 5 5 213JM 7½ – 10 7½ 5 – 7½ 7½ 215JM 10 – 15 10-15 – – – – 254TCZ – – 20 – – – – – 256TCZ – – 25 20 – – – –

GOULDS PUMPS Commercial Water

29

SSH Close Coupled – Dimensions and Weights SSH Acople Cerrado – Dimensiones y Pesos

M-Group Grupo-M

(All dimensions in inches and weights in lbs. Do not use for construction purposes.)

(Todas las dimensiones en pulgadas y pesos en libras. No usar para propósitos de construcción.) CPMAX.

AB

DISCHARGE

MAX.

415⁄16

Y

PRIME PLUG

SUCTION P MAX.

G

E

D

DC DD MAX.

DRAIN PLUG

E

L 3

A

⁄8-19 BSF

F

F

H-4 HOLES

B

Dimensions “L” Determined by Pump and Motor, Dimensiones “L” Determinadas por la Bomba y el Motor CP Max., CP Máx.

Wt. DC Motor Frame Size, Max., (lbs.), Tamaño del Armazón del Motor DD X Y Pump DC Peso Máx. (libras) 140 180 210 250 280 320 360 24SH 1½ x 2 ½-10 1½ 34½ 75 10½ — 2½ 67⁄8 65⁄8 25SH 2 x 2½-10 2 815⁄16 75 111⁄8 4 121⁄8 137⁄8 143⁄8 22SH 2½ x 3-8 36 61⁄8 57⁄8 72 — 15 3 2½ 27SH 2½ x 3-10 84 — — 67⁄8 65⁄8 915⁄16 23SH 3 x 4-8 86 11½ 121⁄8 4 3 37 5 133⁄8 147⁄8 153⁄8 16 28SH 3 x 4-10 75⁄8 73⁄8 111⁄8 98 — — NOTES: NOTAS: * For use with ANSI class 150 mating flanges. * Para usar con bridas que casan ANSI clase 150. 1. Pumps shipped in vertical discharge as standard. 1. Las bombas se transportarán en descarga vertical como Pump Size, Tamaño de la Bomba

Suction*, Discharge*, Succión* Descarga*

For other orientations, remove casing bolts, rotate discharge to desired position, and tighten 3⁄8 – 16 bolts to 12 ft./lbs., 7⁄16 – 14 bolts to 20 ft./lbs., ½ – 13 bolts to 35 ft./lbs. 2. Motor dimensions may vary with motor manufacturer. 3. Not for construction purposes.

Dimensions Determined by JM Motor Frame, Dimensiones Determinadas por el Armazón del Motor JM Frame, Armazón

AB A Max.

B

D

E

F

G

P Max., P Máx. 11 ⁄32 73⁄16 H

1 145JM 6½ 5¼ 6 3½ 2¾ 2½ ⁄8 182JM 2¼ 7 3 8½ 5 ⁄8 6½ 4½ 3¾ ⁄16 8½ 184JM 13 2¾ ⁄32 213JM 7 9½ 73⁄8 8 5¼ 4¼ ⁄32 103⁄16 215JM 3½ 254JM 41⁄8 11¼ 9 11¾ 6¼ 5 13¼ 256JM 5 ¼ 17⁄32 284JM 4¾ 12¼ 12¼ 12¼ 7 5½ 15 286JM 5½ 324JM 5¼ 5 14 13¼ 14 8 6¼ ⁄16 1615⁄16 326JM 6 21 ⁄32 364TCZ 55⁄8 17¾ 151⁄8 15½ 9 7 1 19 1 365TCZ 6 ⁄8

364TCZ and 365TCZ frames are built with 326JM shaft extensions. Dimensions may vary with manufacturer. Los armazones 364TCZ y 365TCZ se construyen con extensiones del eje 326JM. Las dimensiones puede que varíen con los fabricantes.

GOULDS PUMPS Commercial Water

estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 12 pies/libras, 7⁄16 – 14 tornillos a 20 pies/libras, ½ – 13 tornillos a 35 pies/libras. 2. TODAS las dimensiones en pulgadas. 3. No para propósitos de construcción.

Motor Frame Selections, Selecciones del Armazón del Motor Motor Horsepower, Potencia del Motor Wt. 3500 RPM 1750 RPM Frame, Max., Armazón 3 PH, Trifásicos 1 PH, Monofásicos 3 PH, Trifásicos Peso Máx. ODP TEFC ODP TEFC ODP TEFC 145JM – – – – 2 2 57 182JM – – 2 2, 3 3 3 77 184JM – – 3 – 5 5 97 213JM 10 – 5 – 7½ 7½ 141 215JM 15 10 – – 10 10 155 254JM 20 15 – – 15 15 265 256JM 25 20 – – 20 20 320 284JM 30 25 – – 25 25 419 286JM 40 30 – – – – 422 324JM 50 40 – – – – 562 326JM 60 50 – – – – 625 364TCZ 75 60 – – – – 775 365TCZ 100 75, 100 – – – – 905

364TCZ and 365TCZ frames are built with 326JM shaft extensions. Los armazones 364TCZ y 365TCZ se construyen con extensiones del eje 326JM.

30

SSH Frame Mounted – Dimensions and Weights SSH Armazón Montado – Dimensiones y Pesos

S-Group Grupo-S

CP

DISCHARGE DESCARGA

Y

Z

PRIME PLUG X

3

SUCTION SUCCIÓN







1.125 DIA. 1.124 KEYWAY 1⁄8 x ¼, CHAVETERO 1⁄8 x ¼ 7 ⁄16 DIA. – (4) HOLES 7 ⁄16 DIA. – (4) AGUJEROS

DC MAX.DD

DRAIN PLUG

5

L

7

⁄8" – 19 BSP

3

¾

½



Dimensions and Weights – Bare Pump Only, Dimensiones y Pesos – Solamente Bomba 150 lb. Flange, DC CP Brida de 150 lib. Pump, Max., DD Max., L Bomba DC CP Suction*, Discharge*, Máx. Máx. Succión* Descarga* 9SH 10SH 11SH 4SH 7SH 5SH 8SH 6SH

X

Y

Wt. Z (lbs.), Peso (libras)

1 x 2 – 6 5 4¾ 63⁄8 1 163⁄8 77⁄8 3 ⁄8 1 x 2 – 8 2 1 55⁄8 53⁄8 71⁄8 37⁄8 1 x 2 – 10 67⁄8 65⁄8 17¼ 8¾ 87⁄8 4 1½ x 2½ – 6 5 4¾ 16½ 7¾ 63⁄8 3¼ 1½ 1½ x 2½ – 8 55⁄8 53⁄8 2½ 71⁄8 2 x 2½ – 6 5 4¾ 35⁄8 2 17¼ 8½ 4 2 x 2½ – 8 6 5¾ 715⁄16 2½ x 3 – 6 3 2½

* For use with ANSI class 150 mating flanges. * Para usar con bridas que casan ANSI clase 150.

56 64 86 57 65 57 68 59

NOTE: 1. Pumps will be shipped with top vertical discharge as standard. For other orientations, remove casing bolts, rotate discharge to desired position, and tighten 3 ⁄8 –16 bolts to 12 ft./lbs., 7 ⁄16 – 14 bolts to 20 ft./lbs. 2. ALL dimensions in inches. 3. Not for construction purposes.

NOTA: 1. Las bombas se transportarán con la descarga vertical superior como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 12 pies/libras, 7⁄16 – 14 tornillos a 20 pies/libras. 2. TODAS las dimensiones en pulgadas. 3. No para propósitos de construcción.

GOULDS PUMPS Commercial Water

31

SSH Frame Mounted – Dimensions and Weights SSH Armazón Montado – Dimensiones y Pesos

M-Group Grupo-M

CP DISCHARGE

415⁄16

Y

PRIME PLUG

37⁄8 SUCTION

1.625 DIA. 1.624 KEYWAY

61⁄4

3 1 ⁄2

31⁄2

DC

MAX.

DRAIN PLUG

8 1 ⁄2

3⁄16X3⁄8

DD

4 HOLES 9⁄16 DIA .

L

61⁄2

3/8” – BSP

81⁄2

1”

1 ⁄2

Dimensions and Weights – Bare Pump Only, Dimensiones y Pesos – Solamente Bomba Wt. DC Pump Size, (lbs.), Max., S uction*, D ischarge*, DD L X Y Tamaño de Pump CP DC Peso Descarga* la Bomba Succión* Máx. (libras) 24SH 1½ x 2½-10 1½ 125 2½ 67⁄8 65⁄8 25SH 2 x 2½-10 2 815⁄16 125 23 10¼ 4 22SH 2½ x 3-8 61⁄8 57⁄8 125 3 2½ 27SH 2½ x 3-10 134 67⁄8 65⁄8 915⁄16 23SH 3 x 4-8 136 4 3 24 11¼ 5 28SH 3 x 4-10 75⁄8 73⁄8 111⁄8 148 * For use with ANSI class 150 mating flanges. * Para usar con bridas que casan ANSI clase 150.

NOTES: 1. Pumps will be shipped with top vertical discharge as standard. For other orientations, remove casing bolts, rotate discharge to desired position, replace and tighten 3 ⁄8 –16 bolts to 12 ft./lbs. 2. Motor dimensions may vary with motor manufacturer. 3. Not for construction purposes.

GOULDS PUMPS Commercial Water

NOTAS: 1. Las bombas se transportarán con la descarga vertical superior como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 12 pies/libras. 2. TODAS las dimensiones en pulgadas. 3. No para propósitos de construcción.

32

Specifications Especificaciones Capacities to: 1100 GPM (250 m3/hr) at 3500 RPM 775 GPM (177 m3/hr) at 1750 RPM Heads to: 525 feet THD (158 m) at 3500 RPM 130 feet THD (40 m) at 1750 RPM Maximum working pressures to: 230 PSI (15 bars) Maximum temperatures to: 250°F (121°C) All wetted components of AISI: Type 316L stainless steel material. Rotation: Clockwise when viewed from motor end. Enclosed impeller and replaceable wear ring: for high efficiency and maximum wear life. Motor (close coupled): NEMA standard JM shaft open drip-proof, totally enclosed and explosion-proof enclosures, 60 Hz, 1750 or 3500 RPM. Single phase ODP (115/230 V) 1750 RPM, 1 – 5 HP. Three phase ODP. TEFC/Exp. proof (208 – 230/460 V). 3500 RPM, 2 – 100 HP 1750 RPM, 1 – 25 HP

NOTE: Overload protection must be provided. Contactor with overload for single phase or starter with heaters for three phase ordered separately. Motor (frame mounted): NEMA standard T-frame open drip-proof, totally enclosed and explosion-proof (three phase only) enclosures 60 Hz, 1750 or 3500 RPM. Single phase (115/230 V) 1750 RPM, 1 – 5 HP Three phase (208 – 230/460 V) 3500 RPM, 3 – 125 HP 1750 RPM, 1 – 25 HP NOTE: Overload protection must be provided. Contactor with overload for single phase or starter with heaters for three phase ordered separately. Optional: Rigid carbon steel bedplate, sheet metal coupling guard designed to OSHA specifications and T.B. WOODS type “SC” spacer couplings.

Capacidades: 1100 GPM (105 m 3/hr) a 3500 RPM 775 GPM (177 m3/hr) a 1750 RPM Cargas: 525 pies THD (158 m) a 3500 RPM 130 pies THD (40 m) a 1750 RPM Presión de trabajo máxima: 230 PSI (15 baras) Temperatura máxima: 250°F (121°C) Todos los componentes mojados de AISI: Material de acero inoxidable tipo 316L. Rotación: En dirección de las agujas del reloj visto desde el extremo final del motor. Impulsor encerrado y anillo de desgaste reemplazable: para alta eficiencia y máxima durabilidad. Motor (acople cerrado): Eje a prueba de goteo JM estándar NEMA, totalmente encerrado y recintos a prueba de explosión, 60 Hz, 1750 ó 3500 RPM. Unifásicos ODP (115/230 V) 1750 RPM, 1 – 5 HP Trifásicos ODP. TEFC/a prueba de explosión (208 – 230/460 V). 3500 RPM, 2 – 100 HP 1750 RPM, 1 – 25 HP

NOTA: Se debe de proporcionar protección térmica contra sobrecarga. Contactor con protección térmica contra sobrecarga para unifásicos o arrancadores con calentadores para trifásicos se piden por separado. Motor (armazón montado): Armazón abierto T a prueba de goteo estándar NEMA, totalmente encerrado y recintos a prueba de explosión (trifásicos solamente) 60 Hz, 1750 ó 3500 RPM. Unifásicos (115/230 V) 1750 RPM, 1 – 5 HP. Trifásicos (208 – 230/460 V) 3500 RPM, 3 – 125 HP 1750 RPM, 1 – 25 HP NOTA: Se debe de proporcionar protección térmica contra sobrecarga. Contactor con protección térmica contra sobrecarga para unifásicos o arrancadores con calentadores para trifásicos se piden por separado. Opcional: Fundación rígida de acero al carbono, guarda acople de metal laminado diseñado según las especificaciones OSHA y acoples del espaciador T.B. WOODS tipo “SC”.

GOULDS PUMPS Commercial Water

33

Typical Applications Aplicaciones Típicas HVAC, Calefacción, Ventilación y Aire Acondicionado

Water truck, Camión cisterna

GOULDS PUMPS Commercial Water

Specifically designed for all traditional cast iron or bronze fitted water and low grade corrosive services.

Diseñada específicamente para todos los servicios de agua de hierro fundido o recubiertas de bronce y servicios corrosivos de bajo grado.

• Water circulation

• Circulación de Agua

• Booster systems

• Aumento de presión

• Liquid transfer

• Transferencia de líquidos

• HVAC pump replacements

• Reemplazos para bombas HVAC

• General service pumping

• Bombeo de servicios generales

PCB washer, Arandela PCB

Tubing washer, Arandela de tubería

Textile dyes, Colorantes textiles

Reverse osmosis, Ósmosis invertida

Boiler feed, Alimentación de caldera

34

Notes Notas

GOULDS PUMPS Commercial Water

35

IT T

Commercial Water

Goulds Pumps, G&L and the ITT Engineered Blocks Symbol are registered trademarks and tradenames of ITT Industries Inc.

Goulds Pumps, G&L y el símbolo ITT Engineered Blocks son marcas registradas y marcas comerciales de ITT Industries.

SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

LAS ESPECIFICACIONES ESTÁN SUJETAS A CAMBIO SIN PREVIO AVISO.

GLSSH May, 2006 © 2006 ITT Water Technology, Inc.

Mayo, 2006

Engineered for life

View more...

Comments

Copyright ©2017 KUPDF Inc.
SUPPORT KUPDF