gesolar_installationguideedition2011-1

July 26, 2018 | Author: Raam Perumal | Category: Photovoltaics, Electrical Wiring, Solar Panel, Screw, Fuse (Electrical)
Share Embed Donate


Short Description

Download gesolar_installationguideedition2011-1...

Description

Insta Insta lla tion tio n Guid G uid e for fo r G ESO LA R Photovo lta ic Mo Mod d ule ule

G ES-5Mxxx -5M xxx (xxx=170~200) (xxx=170~ 200) G ES-6Mxxx -6M xxx (xxx=205~320) (xxx=205~ 320) GES-6Pxxx (xxx=180~300)

Issue

EN-2011-1

1 / 14

Content Content............................................................................................................................... 1 Introduction ........................................................................................................................ 2 Disc laim er o f liab ility .................................................................................................. 2 Gene ral Safety and Warnings................................................................................... 2 Dimension .......................................................................................................................... 6 Installation .......................................................................................................................... 6 Mec hanica l installation ............................................................................................. 7 Grounding ................................................................................................................. 10 Wiring ................................................................................................................................ 13 Ma inte na nc e & inspe c tio n ............................................................................................. 14 Wa rranty ........................................................................................................................... 14

GESOLAR, Sa inty Interna tion al Grou p Tel: +86-25-52874084 Fa x: +86-25-52875828 中国南京雨花台区软件大道 21 号 C 座 邮编:210012

www.gesolar-power.com

Building C, 21 Ruanjian Road, Nanjing 210012, China

2 / 14

Introduction Tha nk you fo r c ho o sing GESOLAR p ho to vo ltaic (PV) mo d ules. This insta lla tion m a nua l co nta ins imp ortant informa tion ab out safe ty, mec hanica l and electric al installa tion that you m ust know b efo re insta lling GESOLAR PV m o d ules. With p rop er op era tion a nd m a intena nc e, G ESOLAR PV mo d ules will provide you w ith c lea n, rene wa ble sola r elec tricity for ma ny yea rs.

Disc laim er o f Liab ility G ESOLAR d o e s no t a ssum e re sp o nsibility a nd e xpressly d isc laim s lia b ility fo r loss, da m a g e , or expe nse a rising out o f or in a ny wa y c onn ec ted with suc h insta lla tion, op eration use o r ma intena nc e by using this ma nual. No resp o nsibility is a ssum e d b y GESOLAR fo r a ny infring em en t o f p a te nts o r o the r rig hts o f third p a rties, which m a y result from use o f the PV p rod uc t. No licen se is g ra nted b y im plic a tion or oth erwise und er any p at ent or pa tent rig hts. The informa tion in this ma nua l is b elieve d to b e reliab le, but d o es no t c o nstitute a n e xpressed a nd im p lied w a rra nty. GESOA LR reserves the rig ht to m ake c hang es to the p rod uc t, sp ec ific ations, or ma nual without prior notic e.

Gene ral Safety and Warnings In o rd er to use the mo du les p rop erly, avo iding p rop erty losses or injuring the op erato r or anyone else, wa rning s a nd som e o the r c a ution signs a re p rinte d on the solar mo d ules a nd ma nua ls.

■Sign

Introduction

Sign

Warning

Introduction

Me a ns ” Miso p era tion w ill ca use a risk of leth a l or p erso na l serio us injury ”

Me a ns” Miso p era tion w ill c a use a risk of injuring o r prop erty loss ” Caution

GESOLAR, Sa inty Interna tion al Grou p Tel: +86-25-52874084 Fa x: +86-25-52875828 中国南京雨花台区软件大道 21 号 C 座 邮编:210012

www.gesolar-power.com

Building C, 21 Ruanjian Road, Nanjing 210012, China

3 / 14

■Graph

Introduction

Graph

Introduction Prohibited (proc ee ding not p ermitted ) The d et a ils will b e d esc rib ed in the signs, g ra p hs a nd te xts Co mp ulsion (proc ee d ing is c om p ulsory ) The d et a ils will b e d esc rib ed in the signs ,grap hs a nd te xts Ca ution (Wa rning include d ) The d et a ils will b e d esc rib ed in the signs o r g ra p hs a nd te xts

Gene ral Warnings Solar mo d ule insta llation, ma inten an c e, rem ova l and resetting sha ll only be d o ne b y distrib uto r o r p ro fessio na ls If the re a re d efe c ts, there is a risk of e lec tric sho c k or fire. When insta lling , wiring , op erating, rem oving a nd m a inta ining mod ules, p a y a ttent ion to the risk of elec tric shoc k. ●If mo d ule is shined b y sunlig ht o r o the r illumina to r, the DC elec tric ity will be produced.  Artific ially c onc entrate d sunlight shall not b e d irec ted on the m od ule.  Under normal conditions, a photovoltaic module is likely to experience conditions that produce more current and/or voltage than reported at sta nd a rd test c on d itions. Ac c ordingly, the v a lues of ISC a n d VOC ma rked on this module should be multipled by a factor of 1.25 when determining component voltage ratings, conductor ampacities, fuse size, and size of c ontrols c onn ec ted to the PV outp ut. Plea se refer to Sec tion 690-8 of the Nationa l Electric al Co de for an ad ditiona l multiplying fac tor of 125 pe rc ent (80 percent d erating) which ma y be ap plica ble. If modules are connected in series or parallel, the voltage and current  will inc rea se, the d a ng er will b e increa sed trem end ously a c c ordingly. When installing, wiring or maintaining modules, in order to prevent  producing the DC electricity, please cover the module surface with suffic iently o p a q ue stuff. When installing, wiring or maintaining modules, please use protective  instrume nts suc h a s rub b er g love s. If hig h relia b ility is req uired (the m a c hine is rela te d to p erson life), p lea se d on’ t use tho se m od ules. ●Outp ut is unsta b le, serious a c c idenc e suc h a s leth al injure m a y oc c ur. ●The m o d ules a re q ua lified fo r a p p lic a tion c lass A: Ha za rd o us vo ltag e (IEC 61730: higher than 50V DC; EN 61730: higher than 120V), hazardous power a pp lic a tions(highe r than 240W) wh ere ge neral c onta c t a c c ess is a ntic ipa ted (Modules qualified for safety through EN IEC 61730-1 and -2 within this a p p lic a tion c lass a re c onsidered to me et the req uirem ents for Sa fety C la ss II)

GESOLAR, Sa inty Interna tion al Grou p Tel: +86-25-52874084 Fa x: +86-25-52875828 中国南京雨花台区软件大道 21 号 C 座 邮编:210012

www.gesolar-power.com

Building C, 21 Ruanjian Road, Nanjing 210012, China

4 / 14

Wa rning for Installa tion

Insta lling, m a inta ining , rem oving a nd resetting mo d ules sha ll only be d one by distributor or professionals.

Don’t stand or stam p on the sola r mo d ules. Bec a use g lass fac e o f the mo dule will be da ma ge d and it is slipp ery which m ay m a ke injure to someone.

Don’ t to uc h the terminals. The re is a risk of ele c tric shock.

Don ’ t we a r ste el stuff like rings. The re is a risk of ele c tric sho c k.

Sha rp stuff p ro hibited . It m a y punc ture the ba c k of mod ule. The re is a risk of ele c tric sho c k, elec tric ity lea kage and solar mo d ule’s servic e life m ay b e shortened.

Don’t p ut wires be twe en fram e and prop. The w ire m ay b e da ma ged and c ause elec tric shoc k and fire.

When c onnec ting mo dules with othe r controlling de vice , please entrust distributors or professionals.

Don’t d am ag e o r proc ess wiring ma terial. It m a y c a use a risk of elec tric shoc k.

Grounding If not c onnec ted prop erly, it will c a use a risk of e lec tric shoc k. Please d on’ t c onnec t the c ab le with any other p ipes suc h a s g a s pip e, wa ter pipe , thunde r-avoiding rod , etc . Ea c h PV mo d ule ha s a hole on e ac h sid e w ith a g ro und ing sign. The use o f the listed grounding a nd bo nd ing eq uipm en t (KDER), typ e 1954381-1, b y Tyc o Elec tron ic s Corp (E69905), is in order to provide a reliab le grounding c onnec tion to the mod ule frame.

Don ’ t insta ll sola r m o d ules o n mo va b le ob jec ts suc h a s d oo rs, ve hic les. The g la ss m a y b e da ma ge d and c auses injury.

GESOLAR, Sa inty Interna tion al Grou p Tel: +86-25-52874084 Fa x: +86-25-52875828 中国南京雨花台区软件大道 21 号 C 座 邮编:210012

www.gesolar-power.com

Building C, 21 Ruanjian Road, Nanjing 210012, China

5 / 14

Warning for Operating

Do not op en c over of junction b o x, it ma y result in e lec tric shock.

Don’t let c hildren ap proa c h m o d ule s. The re is a risk of elec tric sho c k or injury.

Do not dam ag e or process wiring m a teria l, whic h ma y c a use a risk of elec tric sho c k.

Do not p ric k ba c k of solar mo dule with sharp ob jec ts ot he rw ise m a y result in elec tric shock, electricity leakage or ma ke solar mo dule dam ag ed .

■Warning

for Maintenanc e

Don’t op en c over of junction bo x and c lea n inside with liq uid, it m a y result in elec tric shock.

Don’ t imme rse t he solar mo d ules in liquid , it m a y result in elec tric shoc k.

Do not use d ama ged , ab norma l solar mod ule w hic h ma y c a use risk of elec tric shoc k. If so, p lease c onta c t d istrib uto r or p rofe ssiona ls.

Don’t d eform, me nd solar Mo d ule, it m a y result in elec tric shoc k or be wo unded .

■Caution

Don’t touc h solar mod ules. The m od ule w ill bec om e high temp erature und er sunshine, a nd m a y c a use a risk of sc a lding .

GESOLAR, Sa inty Interna tion al Grou p Tel: +86-25-52874084 Fa x: +86-25-52875828 中国南京雨花台区软件大道 21 号 C 座 邮编:210012

www.gesolar-power.com

Building C, 21 Ruanjian Road, Nanjing 210012, China

6 / 14

Dimension (Mod ule type : GES-5Mxxx, w ith Junc tion b ox, c a ble a nd c onn ec tor)

Front

Side

Backside

Figure 1

GESOLAR, Sa inty Interna tion al Grou p Tel: +86-25-52874084 Fa x: +86-25-52875828 中国南京雨花台区软件大道 21 号 C 座 邮编:210012

www.gesolar-power.com

Building C, 21 Ruanjian Road, Nanjing 210012, China

7 / 14

Installation Mec hanica l Installation Site Sele c tion Plea se selec t the site witho ut sha do ws from tree s or bu ildings, ena b ling the mo d ule t o b e shined b y sun freq uent ly. Esp ec ially in very hot w ea ther, p lease p a y atte ntion the m od ules c a n’ t b e sha d ow ed p a rtly. Furthermo re, in d ifferent sea son , the d ime nsion o f sha d ow c a used b y plan t or a ny othe r ob jec ts will b e c ha ng ed a nd ma y sha d ow som e p ortions of sola r mo d ules, resulting in po wer ge neration red ucing. Plea se m a ke sure tha t th ere a re no ob struct ions in the surro und ing s o f the insta lla tion site. Ta ke p rop er step s in o rd er to ma inta in relia bility a nd sa fety in c a se the PV mo d ules a re insta lled in a rea s tha t ha ve hea vy snow , extrem e c old, stron g winds , insta llations ove r or nea r wa ter an d a rea s wh ere insta lla tions a re p ron e t o sa lt wa te r expo sure o r o n sm a ll island s o r in de sert a rea s. Installa tion Direc tion In orde r to g et b est p ow er prod uc tion, PV mo d ules should typ ic a lly fac e sout h in the no rthern hem isp here, and typic a lly fac e no rth in the south ern hemisp here. Tilt A ng le The tilt a ng le of the PV mo d ule is the an g el be tw ee n PV mo d ule surfa c e a nd horizon ta l leve l. There should b e 5 c m m inimum airspa c e b etw een the lowe st p oint of PV mo d ule a nd mo unting surface.

Rec om m end ed Tilt Angle for a Fixed System Site La titud e in Deg re e s

Fixed Tilt An g le

0° to 15°

15°

15°to 25°

Sa m e a s la titud e

25°to 30°

La titud e + 5°

30°to 35°

La titud e + 10°

35°to 40°

La titud e +15°

40°+

La titu d e +20°

GESOLAR, Sa inty Interna tion al Grou p Tel: +86-25-52874084 Fa x: +86-25-52875828 中国南京雨花台区软件大道 21 号 C 座 邮编:210012

www.gesolar-power.com

Building C, 21 Ruanjian Road, Nanjing 210012, China

8 / 14

Sun light

PV mo d ule

Tilt a ng le ≧5

cm

Ho rizon ta l leve l Mounting g round

Figure 2

Irra d ia tion ea c h d a y will b e d ifferent ac c ording to d ifferent la titude s a ll ove r the e a rth. The op timum an gle is eq ual to latitud e b ut a lso sub jec t to t he d esig n c on d itions suc h a s site a nd de sign ang le, etc . Mo d ules a re a llowe d fo r roo f mo unting a nd should b e m oun ted ove r a fire resista nt roo f c ove ring rate d for the ap plic a tion. But if op era ting time and op erating p urpo se a re limited, the ab ove m entioned d esign m ay no t be op timum , you c an a lso c onta c t distrib utor ab out this. Support Structure Selection In orde r to m a ke PV mod ules ha ve a lon g servic e life o utside p lease p a y atte ntion to the following items: 

Ad op t stron g a nd sa fety struc ture.



Choose durable, corrosion-resistant and UV-resistant material for support module mounting structure.



Follow all kinds of regulations concerned



Don’ t da ma ge a ny pa rts of mo dules for p ow er ge nera tion.



Be ea sy to ma intena nc e



The fo und a tion sha ll b e d one b y professiona l de signer or c onstruc tion c om p a ny Mounting Methods

1. Mo unting w ith Bolts The mo dule must be atta c hed and supp orted by a t lea st four b olts throug h the indica ted m ou nting ho les, as sho wn in Figure 3. Mo st insta lla tions w ill use the fou r inne r mo unting ho les on the m od ule fram e. Dep end ing o n the loc al wind a nd snow loa ds, ad ditiona l mo unting p oints ma y be req uired .

GESOLAR, Sa inty Interna tion al Grou p Tel: +86-25-52874084 Fa x: +86-25-52875828 中国南京雨花台区软件大道 21 号 C 座 邮编:210012

www.gesolar-power.com

Building C, 21 Ruanjian Road, Nanjing 210012, China

9 / 14

Com p onent

Qua ntity

Dime ntion

Ma terial

Bo lt

4

M8

Sta inless ste el

Nut

4

M8

Sta inless ste el

Wa she r

8

M8

Sta inless ste el

Flexib le w a she r

4

M8

Sta inless ste el

Ba c k View of PV Mo d ule

PV Mo d ule Bolt Washer

Sup p o rt Element

Washer Flexible Wa she r 2

3

4

Figure 3

2. Mounting with Clam ping Hardw are

Figure4 GESOLAR, Sa inty Interna tion al Grou p Tel: +86-25-52874084 Fa x: +86-25-52875828 中国南京雨花台区软件大道 21 号 C 座 邮编:210012

www.gesolar-power.com

Building C, 21 Ruanjian Road, Nanjing 210012, China

10 / 14

If mod ule c lam ps are used to sec ure the mo d ule, the torque o n the c lam p bo lt should b e a roun d 8–10 Nm. Four mod ule clam p s sho uld b e used a t least two on e a c h long fra me sid e. Depe nding on the loc al wind a nd snow load s, a d ditiona l mo d ule c lam p s ma y be req uired .

Grounding Introduction All the m od ules should b e g roun d -co nnec ted with the g roun d h oles of the mo d ules. Size o f ea rth and the eq uipm ent g rounding c onduc tor are in a cc orda nce with loc al requireme nts. Attac h the eq uipm ent g rounding c onduc tor to the mo dule fram e using the g rounding hole and hardw are provide d. The g ro und ing c lip a ssem b ly co nsists o f a slid er, ba se, a nd a 8-32 sc rew a nd he x nut. The sc rew is used to mo unt the ground ing c lip to the fram e of the solar mo d ule. The slider is used to hold the wire. The slid er fea tures a m ulti–d ime nsiona l c urved wire slot tha t p rovide s enha nc ed wire rete ntion. The b a se is used to terminate the w ire. The b a se fe a tures p ointed la nc es tha t p rovide four points of c onta c t to the frame for high relia bility and anti–rota tion o f the grounding c lip . The rem ova l slot a c c ep ts the tip o f a fla t–hea d sc rew d rive r wh ic h is used to d iseng a ge the slid er. When t he slid er is d iseng a ge d , the w ire c a n b e rem ove d , a nd the sc rew is expo sed for rem ova l.

Figure 5

Installation 

The g round ing c lip m ust b e p lac ed onto the frame so th a t the sc rew stra d d les a p re–drilled 4.09mm diameter hole.



The sc rew should b e tighte ned to a torque of 2.3 and 2.8 Nm.



The h ea d of the sc rew m ust b e flush with the b a se a nd the b a se m ust b e flush with the frame.



The hex nut m ust b e tight.

GESOLAR, Sa inty Interna tion al Grou p Tel: +86-25-52874084 Fa x: +86-25-52875828 中国南京雨花台区软件大道 21 号 C 座 邮编:210012

www.gesolar-power.com

Building C, 21 Ruanjian Road, Nanjing 210012, China

11 / 14

1 ○

2

3

Figure 6

Rem ova l The w ire c an b e remo ved from the ground ing c lip w hen th e slid er is d iseng a g ed (slid er and sc rew a re exposed ). The sc rew must b e loo sened be fore the g round ing c lip c an b e remove d from the fram e. The g round ing c lip c a n b e re–used up to 5 times a fter prop er rem ova ls (the 8–  32 sc rew and hex nut ca n b e reused ). Repair The grounding c lip is not rep a irab le. Disc ard any d efec tive or da ma ge d grounding c lips.

GESOLAR, Sa inty Interna tion al Grou p Tel: +86-25-52874084 Fa x: +86-25-52875828 中国南京雨花台区软件大道 21 号 C 座 邮编:210012

www.gesolar-power.com

Building C, 21 Ruanjian Road, Nanjing 210012, China

12 / 14

Wiring 

Please notice the correct cable connection polarity when installing the modules. If not connected properly, the bypass diode would be destroyed. For bypass diode, rated current of 15A and Maximum reversing voltage of 45V are chosen for Junction box. Ma xim um

Series fuse ra ting : 8A for GES-5Mxxx (xxx=170~200); 13A for GES-6Mxxx

(xxx=205~320) a nd G ES-6Pxxx (xxx=180~300). 

Modules are equipped with Multi-contact connector as electrical connections. Use the National Electric Code to determine system wiring size (refer to NEC clause 310), type and temperature rating of conductors to be connected to the module's connectors. Wiring connected to the module's wiring should be 1X4.0mm2 (minimum) and rated at 90℃ (minimum).



PV modules can be wired in series to increase voltage as shown in figure 7. In this case, the maximum open circuit voltage must not be greater than the specified maximum system volta ge . The volta ge is p rop ortiona l to the numb er of series.



PV mo d ules c a n b e w ired in pa ra llel to in inc rea se th e c urrent a s sho wn in figure 8. In c a se of parallel connection, please take proper measure to block the reverse current flow. Otherwise, the current may easily flow in a reverse direction.

Figure 7

Figure 8

GESOLAR, Sa inty Interna tion al Grou p Tel: +86-25-52874084 Fa x: +86-25-52875828 中国南京雨花台区软件大道 21 号 C 座 邮编:210012

www.gesolar-power.com

Building C, 21 Ruanjian Road, Nanjing 210012, China

13 / 14

Ma intenanc e & inspe c tion Solar mo d ules req uire ve ry little ma inte na nc e. It is no t unc om mo n for a rem ote site to b e c hec ked b ut onc e p er yea r. Und er mo st c ond itions, norma l ra infa ll is suffic ient to keep the mo d ule g lass c lea n. If d irt b uild -up b ec om es exce ssive, c lean the gla ss with a soft c loth using mild d etergent a nd wa ter. Mod ules that are mo unted , flat (0° tilt angle) should b e c lea ned mo re o ften, as the y won ’ t "self clea n" a s effe c tively as mo d ules mo unted a t 15° or a g rea ter tilt. Onc e a year, c hec k the tightness of te rminal sc rew s and the ge neral cond ition of the wiring. Also, c hec k to b e sure th a t mo unting ha rdw a re is tight. Loo se b olts c ould result in a d a ma ge d mo d ule or a rra y.

Warranty Deta iled w a rra nty te rms p lease refe r to “ Limited Pow er Wa rra nty fo r PV Mo d ules” .

GESOLAR, Sa inty Interna tion al Grou p Tel: +86-25-52874084 Fa x: +86-25-52875828 中国南京雨花台区软件大道 21 号 C 座 邮编:210012

www.gesolar-power.com

Building C, 21 Ruanjian Road, Nanjing 210012, China

View more...