Gesamtkatalog

March 8, 2018 | Author: Eduard Riemschneider | Category: Ac Power Plugs And Sockets, Pipe (Fluid Conveyance), Soldering, Screw, Manmade Materials
Share Embed Donate


Short Description

HZ Gesamtkatalog Englisch...

Description

2003 / 2004

Steigstrangprofile

Main Catalogue

Heizkörperanbindesysteme

Table of Contents

2

6

The different types of brackets

7

SLF 2000 – The universal profile for pipes up to 22 mm

8 / 9

SLT 2000 – The profile with self-adhesive tape for use with carpets, for pipes up to 22 mm

10 / 11

SLL 2000 – The profile for use with a cable duct or a 3rd pipe up to 22 mm

12 / 13

SLF 28-2000 – The profile for pipes up to 28 mm and when more space is needed

14

SLHW – Skirting board of wood-based material in natural, or in light oak or abachi veneers Range of corner moulded parts / Methods of installation BLF – Dummy skirting board profiles made of plastic hollow space profile

15 16 / 17 18

BLT / BL – Carpet dummy skirting board and dummy skirting board made of solid wood

19

Accessories for Skirting Boards

20

Radiator Connection Systems HKU - The easy and complete way to connect radiators

21

HKU - Radiator connections for soldering

22 / 23

HKU - Radiator connections for press-fitting

24 / 25

HKU - Radiator connections with tapered seal / female thread / for push-fitting

26 / 27

AWA / PBV – 90° elbows with shut off valve / 90° bends

28 / 29

Radiator Connection Systems Heizkörperanbindesysteme

The HZ System for Pre-Wall Installation

Skirting Board Profiles

Skirting Board Profiles

STK - Riser unions

30

STP U - Riser section, plastic, U-shaped

31

STP U - Riser section, plastic, L-shaped

32

Accessories for Riser Systems

33

Request for Promotional Material

34

Company Portrait

35

Riser Sectionsle Steigstrangprofi

Riser Sections

Please observe our guidelines for installation

3

4

Skirting Board Profiles Radiator Connection Systems Heizkörperanbindesysteme 2

1

1

HZ Skirting boards for concealing heating pipes and electrical wiring.

2

HZ Riser sections for concealing pipes on walls and ceilings.

3

HZ Radiator connections for quick connection of radiators with pre-wall installation.

Riser Sections Steigstrangprofile

3

5

The HZ System for Pre-Wall Installation

The advantages of pre-wall installation when modernising heating systems are obvious: no need to chisel out chasing, no rubble in rooms which are occupied, no extra renovation work, quick installation times, savings in expense. State-of-the-art pre-wall installation consists of cladding heating pipes that are laid on top of plaster. HZ supplies the right system for cladding pipes. Heating pipes parallel to the floor are concealed with the high-quality HZ skirting board profiles. A wide range of décors and different sized skirting boards will meet practically any conceivable requirement. HZ’s simple fixing methods ensure quick and easy installation. For vertical piping HZ supplies riser sections in U and L shapes in a total of seven different sizes. Pipes along walls and ceilings can be concealed without any difficulty. They are indispensable for cladding insulated risers. Fast and attractive fitting of radiators can be achieved using the HZ radiator connection systems for pre-wall installation. They are available for all types of connections: soldering - press-fitting - screwing - push-fitting. Use these and you will save considerable time in pre-wall installation. Particular importance is attached to easy installation for HZ products. Even with difficult installation situations in older buildings, fast and problem-free mounting is possible.

6

The different types of brackets

Open bracket 2150 for mounting after laying pipes* • Two-part adjustable-height bracket

• Suitable for pipes up to 22 mm Ø

• Attach with nail plug art. no. 208 or screw plug art. no. 209

• Adjustable-height slide locks into position

• Brackets art. nos. 2150 and 2250 can be combined

• Additional mounting with nail plug art. no. 204 for uneven walls

Skirting Board Profiles

Brackets

• Two-part adjustable-height bracket • Attach with nail plug art. no. 210 • Suitable for pipes up to 28 mm Ø

• Adjustable-height slide locks into position • Additional mounting with nail plug art. no. 204 for uneven walls

Closed bracket 2250 for mounting before laying pipes* • Three-part adjustable-height bracket

• Suitable for pipes up to 22 mm Ø

• Use the clasp to close up the bracket after inserting the pipes

• Large contact area with the wall ensures solid support on uneven walls and damaged plaster

• Attach with nail plug art. no. 208 or screw plug art. no. 209

• Adjustable-height slide locks into position

• Brackets art. no. 2150 and art. no. 2250 can be combined

Radiator Connection Systems

Open bracket 2450 for mounting after laying pipes*

Open inner corner bracket 2151 for mounting after laying pipes • The bracket fits corners from 85 °-100 °

• Suitable for pipes up to 22 mm Ø and press-fit systems up to 18 mm Ø

• Attach with nail plug art. no. 208 or screw plug art. no. 209

Open outer corner bracket 2152 for mounting after laying pipes • The bracket fits corners from 85 °-100 °

• Suitable for pipes up to 22 mm Ø and press-fit systems up to 18 mm Ø

• Stable guidance so that outer corner can be slid on easily • Adjustable-height slide locks into position

Riser Sections

• Stable guidance so that inner corner can be slid on easily • Adjustable-height slide locks into position

• Attach with nail plug art. no. 208 or screw plug art. no. 209

Brackets should not be spaced more than 50 cm apart. If the walls are damaged or uneven, reduce spacing accordingly. For brackets Art.nos. 2150, 2250 and 2450 the following applies: to ensure that mounting is not under any strain, we recommend positioning the bracket 1 – 3 mm from the floor.

7

SLF 2000

The universal profile up to 22 mm in eight finishes

The SLF 2000 profile is the universal skirting board profile for pipes up to 22 mm Ø. It is a robust plastic hollow space profile with a sealing lip on the wall in order to compensate for uneven walls. The outstanding feature of the profile‘s extremely durable material is its high impact resistance. Dummy skirting boards to match the SLF 2000 profile are available for walls without pipes (see page 18). The profile is attached after laying the pipes with the bracket art. no. 2150 or before laying pipes with bracket art. no. 2250.

39

95

34

80

35

72

Ø 22

~2 17

+17

0

The bracket art. no. 2250 is particularly well suited for uneven walls, damaged or soft plaster. We recommend spacing the brackets every 50 cm. If there are problems with the walls, space the brackets more closely together. The brackets are attached with nail plug art. no. 208. For corner solutions there is a choice between the HZ 2000 corners and the corners for custom solutions. You will find assistance in choosing the right corner solution on pages 16 and 17.

-7

Dimensions of SLF 2000 profile, here with bracket 2150

HZ bracket art. no. 2150 (SCH 2150) Bracket for mounting over pipes after laying, up to 22 mm. Fits all HZ SLF 2000, HZ SLT 2000 and HZ SLL 2000 profiles. Packing unit: 40 pces Number required: 2 per metre To ensure that mounting is not under any strain, we recommend positioning the bracket 1 – 3 mm from the floor.

HZ bracket art. no. 2250 (SCH 2250) Bracket for mounting under pipes prior to laying, up to 22 mm. Fits all HZ SLF 2000, HZ SLT 2000 and HZ SLL 2000 profiles. Packing unit: 40 pces Number required: 2 per metre To ensure that mounting is not under any strain, we recommend positioning the bracket 1 – 3 mm from the floor.

HZ bracket art. no. 2151 (IE SCH 2151) Bracket for mounting over pipes after laying, up to 22 mm, for press-fit systems up to 18 mm. Only for use with IE 2000, IET 2000 and IEL 2000 in matching finish. Packing unit: 40 pces Number required: 1 per inner corner

HZ bracket art. no. 2152 (IE SCH 2152) Bracket for mounting over the pipes after laying, up to 22 mm, for press-fit systems up to 18 mm. Only for use with AE 2000, AET 2000 and AEL 2000 in matching finish. Packing unit: 40 pces Number required: 1 per outer corner

Nail plug art. no. 208 (ND 80-8) Wall plug with countersunk head and threaded nail. Packing unit: 50 pces Requirements: 1 per bracket, 2 per corner bracket Please use article 204 to provide the bracket 2150 with additional fastening!

Nail plug art. no. 204 (ND 40-6) Wall plug with countersunk head and threaded nail. Packing unit: 50 pces Requirements: 1 pce. to provide the bracket 2150 with additional fastening.

Screw plug art. no. 209 (DHB 80-8)

8

Screw plug for hollow block & Rigips (plasterboard) walls Packing unit: 50 pces Number required:1 per bracket, 2 per corner bracket Note: Torx contour

Dark beech 2030

White ash 2040 When using the HZ 2000 inner corner you need an inner corner bracket (art. no. 2151), when using the HZ 2000 outer corner an outer corner bracket is needed (art. no. 2152). When cutting the skirting board profile to size, remember that for each inner corner bracket used the profile has to be shortened by 45 mm.

Light oak 2060

The corner brackets provide solid support for the profile and the corner moulded parts and no mitre cut is needed. This saves valuable time in installation. The profile is pressed against the wall and pushed down into the brackets. The inner and outer corners are slid over the square-cut skirting boards onto the corner brackets.

Dark oak 2070

With the SLF 2000 profile you can choose from eight finishes and matching White (≈RAL 9010) moulded parts. 2080 Together with the HZ radiator connections you can achieve a technically sophisticated solution and an attractive appearance. With very uneven walls and floors we recommend using an additional sealing lip which can be stuck on (see page 20).

SLF 2000 profile Skirting board made of plastic hollow space profile Packing unit: 40 m Length: 4 m

Inside corner IMPORTANT: Only for use in combination with IE SCH 2151 Packing unit: 10 pces

Outside corner IMPORTANT: Only for use in combination with AE SCH 2152 Packing unit: 10 pces

Butt joint Packing unit: 10 pces Same article also for BLF, see page 18

Grey (≈RAL 7035) 2090

Left end piece

Right end piece

Packing unit: 10 pces Same article also for BLF, see page 18

Packing unit: 10 pces Same article also for BLF, see page 18

Inner corner for Outer corner for custom solutions custom solutions For working without inner corner brackets, (also for BLF or transition piece from BLF to SLF) Packing unit: 10 pces

For working without outer corner brackets, (also for BLF or transition piece from BLF to SLF) Packing unit: 10 pces

Maple Art. no. 2010 (SLF 2000 A)

Maple Art. no. 2011 (IE 2000 A)

Maple Art. no. 2012 (AE 2000 A)

Maple Art. no. 2013 (ST A)

Maple Art. no. 2014 (ES A left)

Maple Art. no. 2015 (ES A right)

Maple Art. no. 2016 (IE A)

Maple Art. no. 2017 (AE A)

Light beech Art. no. 2020 (SLF 2000 BH)

Light beech Art. no. 2021 (IE 2000 BH)

Light beech Art. no. 2022 (AE 2000 BH)

Light beech Art. no. 2023 (ST BH)

Light beech Art. no. 2024 (ES BH left)

Light beech Art. no. 2025 (ES BH right)

Light beech Art. no. 2026 (IE BH)

Light beech Art. no. 2027 (AE BH)

Dark beech Art. no. 2030 (SLF 2000 BD)

Dark beech Art. no. 2031 (IE 2000 BD)

Dark beech Art. no. 2032 (AE 2000 BD)

Dark beech Art. no. 4133 (ST BD)

Dark beech Art. no. 4134 (ES BD left)

Dark beech Art. no. 4135 (ES BD right)

Dark beech Art. no. 4131 (IE BD)

Dark beech Art. no. 4132 (AE BD)

White ash Art. no. 2040 (SLF 2000 EW)

White ash Art. no. 2041 (IE 2000 EW)

White ash Art. no. 2042 (AE 2000 EW)

White ash Art. no. 4143 (ST EW)

White ash Art. no. 4144 (ES EW left)

White ash Art. no. 4145 (ES EW right)

White ash Art. no. 4141 (IE EW)

White ash Art. no. 4142 (AE EW)

Light oak Art. no. 2060 (SLF 2000 EH)

Light oak Art. no. 2061 (IE 2000 EH)

Light oak Art. no. 2062 (AE 2000 EH)

Light oak Art. no. 163 (ST EH)

Light oak Art. no. 164 (ES EH left)

Light oak Art. no. 165 (ES EH right)

Light oak Art. no. 161 (IE EH)

Light oak Art. no. 162 (AE EH)

Dark oak Art. no. 2070 (SLF 2000 ED)

Dark oak Art. no. 2071 (IE 2000 ED)

Dark oak Art. no. 2072 (AE 2000 ED)

Dark oak Art. no. 173 (ST ED)

Dark oak Art. no. 174 (ES ED left)

Dark oak Art. no. 175 (ES ED right)

Dark oak Art. no. 171 (IE ED)

Dark oak Art. no. 172 (AE ED)

White Art. no. 2080 (SLF 2000 W)

White Art. no. 2081 (IE 2000 W)

White Art. no. 2082 (AE 2000 W)

White Art. no. 183 (ST W)

White Art. no. 184 (ES W left)

White Art. no. 185 (ES W right)

White Art. no. 181 (IE W)

White Art. no. 182 (AE W)

Grey Art. no. 2090 (SLF 2000 G)

Grey Art. no. 2091 (IE 2000 G)

Grey Art. no. 2092 (AE 2000 G)

Grey Art. no. 193 (ST G)

Grey Art. no. 194 (ES G left)

Grey Art. no. 195 (ES G right)

Grey Art. no. 191 (IE G)

Grey Art. no. 192 (AE G)

Riser Sections

Light beech 2020

Radiator Connection Systems

Skirting Board Profiles

Maple 2010

9

SLT 2000

The profile with self-adhesive tape for laying carpets, for pipes up to 22 mm in two finishes

The SLT 2000 profile is used when you want the carpet to determine the appearance of the skirting board. The profile has self-adhesive tape so that the carpet can be laid. It is a robust plastic hollow space profile with a sealing lip on the wall to compensate for uneven surfaces. The outstanding feature of the profile’s extremely durable material is its high impact resistance. Matching dummy skirting boards (see page 18) are also available.

46

40

35

79 96

Ø 22

+19

~2

23

Carpet depth: 80 mm

7

0

The self-adhesive tape is only suitable for carpets with a smooth foam coating. With other carpeting additional contact adhesive or additional double-sided adhesive tape is necessary. The profile is attached similarly to the SLF 2000 profile with the bracket art. no. 2150 after laying pipes, or with the bracket art. no. 2250 before laying pipes, in which case bracket art. no. 2250 is also particularly well suited for uneven walls. We recommend spacing the brackets every 50 cm. If there are problems with the walls, space the brackets more closely together.

-5

The brackets are attached with nail plug art. no. 208. Dimensions of SLT 2000 profile, here with bracket 2250

HZ bracket art. no. 2150 (SCH 2150) Bracket for mounting over pipes after they have been laid, up to 22 mm. Fits all HZ SLF 2000, HZ SLT 2000 and HZ SLL 2000 profiles. Packing unit: 40 pces Number required: 2 per metre. To ensure that mounting is not under any strain, we recommend positioning the bracket 1–3 mm from the floor.

HZ bracket art. no. 2250 (SCH 2250) Bracket for mounting under pipes prior to laying, up to 22 mm. Fits all HZ SLF 2000, HZ SLT 2000 and HZ SLL 2000 profiles. Packing unit: 40 pces Number required: 2 per metre To ensure that mounting is not under any strain, we recommend positioning the bracket 1–3 mm from the floor.

HZ bracket art. no. 2151 (SCH 2151) Bracket for mounting over pipes after they have been laid, up to 22 mm, for press-fit systems up to 18 mm. Only for use with IE 2000, IET 2000 and IEL 2000 in matching finish. Packing unit: 40 pces Number required: 1 per inner corner

HZ bracket art. no. 2152 (SCH 2152) Bracket for mounting over pipes after they have been laid, up to 22 mm, for press-fit systems up to 18 mm. Only for use with AE 2000, AET 2000 and AEL 2000 in matching finish. Packing unit: 40 pces Number required: 1 per outer corner

Nail plug art. no. 208 (ND 80-8) Wall plug with countersunk head and threaded nail. Packing unit: 50 pces. Requirements: 1 per bracket, 2 per corner bracket Please use article 204 to provide additional mounting for bracket 2150!

Screw plug art. no. 209 (DHB 80-8) Screw plug for hollow block & Rigips (plasterboard) walls Packing unit: 50 pces Number required:1 per bracket, 2 per corner bracket Note: Torx contour

10

Skirting Board Profiles

Light oak 2260

White (≈RAL 9010) 2280

With the corners of the SLT 2000 profile you can also choose between the HZ 2000 corners and the corners for custom solutions. When using the HZ 2000 inner corner you need an inner corner bracket (art. no. 2151), when using the HZ 2000 outer corner an outer corner bracket is needed (art. no. 2152). When cutting the skirting board profile to size, remember that for each inner corner bracket used the profile has to be shortened by 45 mm.

The inner and outer corners for custom solutions are used when more space is needed in the corners. This may be the case with press-fit systems. The corners are then pressed sideways onto the skirting boards which have a mitre cut. You will find assistance in choosing the right corner solution on pages 16 and 17. The profile is pressed against the wall and pushed down into the brackets. The inner and outer corners are slid over the square-cut skirting boards onto the corner brackets. Combined with the HZ radiator connections you will be able to obtain a perfect appearance. In the case of walls which are very uneven we recommend using an additional sealing lip that is stuck on. You can find these on page 20.

Carpet skirting boards Skirting boards for carpet insert with self-adhesive tape Packing unit: 40 m Length: 4 m

Inner corner

Outer corner

Butt joint

Left end piece

Right end piece

IMPORTANT: Only for use in combination with IE SCH 2151 Packing unit: 10 pces

IMPORTANT: Only for use in combination with AE SCH 2152 Packing unit: 10 pces

Packing unit: 10 pces

Packing unit: 10 pces

Packing unit: 10 pces

Inner corner for Outer corner for custom solutions custom solutions For working without inner corner brackets, Packing unit: 10

For working without outer corner brackets, Packing unit: 10

Light oak Art. no. 2260 (SLT 2000 EH)

Light oak Art. no. 2261 (IET 2000 EH)

Light oak Art. no. 2262 (AET 2000 EH)

Light oak Art. no. 263 (STT EH)

Light oak Art. no. 264 (EST EH left)

Light oak Art. no. 265 (EST EH right)

Light oak Art. no. 261 (IET EH)

Light oak Art. no. 262 (AET EH)

White Art. no. 2280 (SLT 2000 W)

White Art. no. 2281 (IET 2000 W)

White Art. no. 2282 (AET 2000 W)

White Art. no. 283 (STT W)

White Art. no. 284 (EST W left)

White Art. no. 285 (EST W right)

White Art. no. 281 (IET W)

White Art. no. 282 (AET W)

Riser Sections

Radiator Connection Systems

The corner brackets provide firm support for the profile and the corner moulded parts. When using the corner brackets no mitre cut is required. This saves valuable time in installation.

11

SLL 2000

SLL 2000 – The profile for inserting a cable duct or a 3rd pipe up to 22 mm, in three finishes

The SLL 2000 profile is used when a cable duct is also laid (recommended 30 x 30 mm) or when laying a 3rd pipe. It is a robust plastic hollow space profile with a sealing lip on the wall in order to compensate for uneven walls. When used in conjunction with the socket container it is the ideal profile for quick and inexpensive modernisation of your home. It is mounted after laying the pipes with the bracket art. no. 2150 or before laying them with bracket art. no. 2250.

39

127

35

107

Ø 22

30

0

51

68

(+20)

Dimensions of the SLL 2000 profile, here with bracket 2250 and commercial cable duct e.g. Tehalit 30 x 30 mm

We recommend spacing the brackets every 50 cm. If there are problems with the walls, space the brackets more closely together. When cutting the skirting board profile to size, remember that for each inner corner bracket used the profile has to be shortened by 45 mm. If a cable duct is also laid, the bracket is mounted above the cable duct and the slide can be slid on as far as the cable duct. With bracket art. no. 2150 care must be taken that a minimum spacing of at least 6 mm is kept to and that it is not mounted on top of the cable duct. When laying a third pipe the bracket is positioned between the two top pipes. The bracket art. no. 2150 should also be mounted between the two lower pipes without a slide, in order to give the 3rd pipe solid support. There is a choice for corner solutions between the HZ 2000 corners and the corners for custom solutions. You will find assistance in choosing the right corner solution on pages 16 and 17.

HZ bracket art. no. 2150 (SCH 2150) Bracket for mounting over pipes after laying, up to 22 mm. Fits all HZ SLF 2000, HZ SLT 2000 and HZ SLL 2000 profiles. Packing unit: 40 pces Number required: 2 per metre.

HZ bracket art. no. 2250 (SCH 2250) Bracket for mounting under pipes prior to laying, up to 22 mm. Fits all HZ SLF 2000, HZ SLT 2000 and HZ SLL 2000 profiles. Packing unit: 40 pces Number required: 2 per metre.

HZ bracket art. no. 2151 (IE SCH 2151) Bracket for mounting over the pipes after laying them, up to 22 mm, for press-fit systems up to 18 mm. Only for use with IE 2000, IET 2000 and IEL 2000 in matching finish. Packing unit: 40 pces Number required: 1 per inner corner

HZ bracket art. no. 2152 (IE SCH 2152) Bracket for mounting over the pipes after laying them, up to 22 mm, for press-fit systems up to 18 mm. Only for use with AE 2000, AET 2000 and AEL 2000 in matching finish Packing unit: 40 pces Number required: 1 per outer corner

Nail plug art. no. 208 (ND 80-8) Wall plug with countersunk head and threaded nail. Packing unit: 50 pces Requirements: 1 per bracket, 2 per corner bracket Please use article 204 to provide additional mounting for bracket 2150!

Screw plug art. no. 209 (DHB 80-8) Screw plug for hollow block & Rigips (plasterboard) walls Packing unit: 50 pces Number required:1 per bracket, 2 per corner bracket Note: Torx contour

12

Grey (≈RAL 7035) 2390

The profile is pressed against the wall and pushed down into the brackets. The inner and outer corners are slid over the square-cut skirting boards onto the corner brackets. With the SLL 2000 profile you can choose from three finishes and matching moulded parts.

The test report from the informative inspection by the VDE institute dated 21.06.96, ref. 196928100-4001-A3D, is available from Hans Weitzel GmbH & Co. KG. Please request our separate planning instructions and the guidelines for installation.

The SLL profile is suitable for HZ radiator connections.

Rules for installation: 1. Forward - always upper pipe 2. Backflow - always lower pipe 3. Cable ducts from 30 x 30 mm, use those with VDE approval symbol (e.g. Tehalit LF 30030) 4. It is essential to observe the separate instructions for planning and guidelines for installation.

The socket container matching the SLL profile is suitable for sockets, TV aerial and telephone outlets as well as outlets for data transmission. The socket containers in white plastic are available in two different designs. The container, consisting of rear and front pieces, is easy to install. The socket container art. no. 331 is designed for sockets with a central disc and without frame (recess opening 62 x 62 mm, make GIRA, SCHUKO socket 16/250, art. no. 188XX), the socket container art. no. 332 is designed for commercial electrical outlets and Schuko earthed sockets with a full plate (recess opening 73 x 73 mm).

90

a

222

a

a

The sockets themselves are not included in the scope of supply!

68+3

Ø 22

52

Refer to description of article for outlet dimensions

HZ socket container art. no. 331 (SDC 62x62) Socket container: plastic, white, similar to RAL 9010, recess opening 62x62 mm, suitable for sockets, TV aerial and telephone outlets, outlets for data transmission, not included in the scope of supply, container consists of front and rear pieces for simple mounting. Only suitable for Gira sockets (S-Color)

Radiator Connection Systems

White (≈RAL 9010) 2380

Skirting Board Profiles

Light oak 2360

HZ socket container art. no. 332 (SDC 73x73)

SLL 2000 profile Inner corner Skirting boards made of plastic hollow space profile for cable duct or 3rd pipe Packing unit: 40 m Length: 4 m

IMPORTANT: Only use in combination with IE SCH 2151 Packing unit: 10 pces

Outer corner

Butt joint

Left end piece

Right end piece

IMPORTANT: Only use in combination with AE SCH 2152 Packing unit: 10 pces

Packing unit: 10 pces

Packing unit: 10 pces

Packing unit: 10 pces

Inner corner for Outer corner for custom solutions custom solutions For working without inner corner brackets Packing unit: 10 pces

For working without outer corner brackets Packing unit: 10 pces

Light oak Art. no. 2360 (SLL 2000 EH)

Light oak Art. no. 2361 (IEL 2000 EH)

Light oak Art. no. 2362 (AEL 2000 EH)

Light oak Art. no. 363 (STL EH)

Light oak Art. no. 364 (ESL EH left)

Light oak Art. no. 365 (ESL EH right)

Light oak Art. no. 361 (IEL EH)

Light oak Art. no. 362 (AEL EH)

White Art. no. 2380 SLL 2000 W)

White Art. no. 2381 (IEL 2000 W)

White Art. no. 2382 (AEL 2000 W)

White Art. no. 383 (STL W)

White Art. no. 384 (ESL W left)

White Art. no. 385 (ESL W right)

White Art. no. 381 (IEL W)

White Art. no. 382 (AEL W)

Grey Art. no. 2390 (SLL 2000 G)

Grey Art. no. 2391 (IEL 2000 G)

Grey Art. no. 2392 (AEL 2000 G)

Grey Art. no. 393 (STL G)

Grey Art. no. 394 (ESL G left)

Grey Art. no. 395 (ESL G right)

Grey Art. no. 391 (IEL G)

Grey Art. no. 392 (AEL G)

Riser Sections

Socket container: plastic, white, similar to RAL 9010, recess opening 73x73 mm, suitable for sockets, TV aerial and telephone outlets, outlets for data transmission, not included in the scope of supply, container consists of front and rear pieces for simple mounting.

13

SLF 28-2000

The profile for pipes up to 28 mm and when more space is needed, in two finishes

The SLF 28-2000 profile is a robust plastic hollow space profile with a sealing lip on the wall in order to compensate for uneven walls. It is used for example with pipes up to 28 mm, with press fittings up to 22 mm and with the HZ insulation hose for pipes up to 22 mm. You will find a detailed summary of areas of application depending on the pipes used on pages 16 and 17. Corner brackets are dispensed with in the case of the SLF 28-2000 profile in order to ensure maximum free space in the corners.

45

83 40 40

92 110

Ø 28

~2 20

+17

0 -7

Bracket art. no. 2450 is used for mounting, providing all the advantages of bracket art. no. 2150 with larger dimensions. The profile and the matching moulded parts are available in light oak and white finishes. We recommend spacing the brackets every 50 cm. If there are problems with the walls, space the brackets more closely together. When walls and floors are very uneven we recommend using an additional sealing lip. This can be stuck on the skirting board both towards the wall and towards the floor. This achieves an extra 10 mm length in the profile. The sealing lip and other accessory parts for the skirting boards can be found on page 20.

Dimensions of SLF 28 -2000 profile, with bracket 2450

HZ bracket art. no. 2450 (SCH 2450) Bracket for mounting over pipes once they have been laid, up to 28 mm. Fits all HZ SLF 28-2000 profiles. Packing unit: 40 pces Number required: 2 per metre. To ensure that mounting is not under any strain, we recommend positioning the bracket 1–3 mm from the floor.

Nail plug art. no. 210 (ND 100-8) Wall plug with countersunk head and threaded nail. Packing unit: 50 pces Requirements: 1 per bracket SCH 2450 The nail wall plug is also suitable for soft surfaces for all other HZ 2000 brackets.

Nail plug art. no. 204 (ND 40-6) Wall plug with countersunk head and threaded nail. Packing unit: 50 pces Requirements: 1 pce. for additional mounting of the bracket 2450.

SLF 28 -2000 profile

Light oak

Skirting board for pipes up to 28 mm, plastic hollow space profile. Packing unit: 40 m Length: 4 m

Inside corner

Outer corner

Butt joint

Left end piece

Right end piece

Packing unit: 10 pces

Packing unit: 10 pces

Packing unit: 10 pces

Packing unit: 10 pces

Packing unit: 10 pces

White (≈RAL 9010)

14

Light oak Art. no. 2460 (SLF 28-2000 EH)

Light oak Art. no. 5161 (IE 28 EH)

Light oak Art. no. 5162 (AE 28 EH)

Light oak Art. no. 5163 (ST 28 EH)

Light oak Art. no. 5164 (ES 28 EH left)

Light oak Art. no. 5165 (ES 28 EH right)

White Art. no. 2480 (SLF 28-2000 W)

White Art. no. 5181 (IE 28 W)

White Art. no. 5182 (AE 28 W)

White Art. no. 5183 (ST 28 W)

White Art. no. 5184 (ES 28 W left)

White Art. no. 5185 (ES 28 W right)

Skirting Board Profiles

SLHW

Skirting board of wood-based material

The HW – skirting board from robust wood-based material is available in natural, or in light oak or abachi veneers. It is suitable for pipes up to 22 mm in diameter with fitting for soldering and up to 18 mm diameter with press fitting.

To achieve a high quality opaque paint finish the Caparol company recommends sanding the profile and applying a coat of primer (Capacryl Haftprimer).Then apply an opaque coat of paint with Capacryl Seidenglanz paint (various colours) or Capalac Superweiss (similar to RAL 9010). The HW – skirting boards with a veneer are for staining, for varnishing or applying an opaque coat of paint. The HZ radiator connection art. no. 1315 / 1318 can be used in conjunction with the HW skirting board for copper soldering DN 15 and DN 18. Remove the centre ridge using pliers!

SLHW skirting board

Skirting board for 2 pipes for 18 mm Ø press-fit and 22 mm Ø solder systems Packing unit: 20 m Length: 4 m

Dimensions of the SLHW wood-based material skirting board

End piece Suitable for art. nos. 134, 136 and 138 Can be used on the left and the right Packing unit: 10 pces

Natural Natural End piece Art. no. 134 Art. no. 133 (SLHW can be painted) (HW E)

~22

~44

28

The HW – skirting board Natural is only intended for painting (NOT for staining).

Riser Sections

~44

29

90

In order to obtain an accurate mitre cut we offer our mitre cutting device or precision saw (see page 20). Please note that laying HZ insulation hoses (see page 20) over the entire area under the skirting board will reduce noise emission and loss of heat.

Radiator Connection Systems

34

It is mounted with a cheese-head or spax screw. In the corners the profile is given an exact mitre cut.

Light oak

Light oak Art. no. 136 (SLHW EH can be stained) Abachi Art. no. 138 (SLHW A can be stained)

Abachi 15

Different methods of installation in corners offered by the HZ 2000 System

1

Use of inner and outer corner moulded parts in matching finish plus inner and outer corner brackets (with SLF 2000, SLT 2000, SLL 2000). The profile is cut to length at a right angle.

2

Use of inner and outer corner moulded parts for custom solutions without corner bracket (for SLF 2000, SLT 2000, SLL 2000) The profile is MITRE CUT.

3

Use of the SLF 28-2000 profile with matching inner and outer corner form parts without corner bracket. The profile is MITRE CUT.

Which of the various methods of installation is chosen depends on the available space in each case. When more space is needed, using the above solution 2 or 3 is possible without any problems. More space is needed, for instance, when larger diameter pipes are used entailing the use of larger fittings or bending radii. Fittings and pipes from various manufacturers were tested in conjunction with the installation of the HZ 2000 System in a 90 ° corner. The following possible solutions for mounting different pipe diameters have proven themselves (see chart on right):

Note: When mounting an inner or outer corner bracket the maximum outer diameter of the fitting and the pipe should be checked, unless the system is listed on the next page. 16

W ith

Be n

Aquatherm SHT

16

16

20

20*

20

20

Fränkische

Alpex duo

16

16

20

20*

26

20

Geberit

Mepla Quattro

20

16

20

20

26

20

Giacomini

R 999

--

18

20

20*

20

20

IBP

B-press

18

--

18

--

22

--

IBP

Cuprofit

18

--

18

--

22

--

JRG

Sanipex MT

16

16

16

20

20

20

Mapress

Mapress copper

18

--

18

--

22

--

Mapress

c-steel

18

--

18

--

22

--

Oventrop

Copipe

20

18

20

20*

26

20

Polytherm

Polyfix MT

20

16

20

20*

26

20

Roth

Roth Alu Laserpex

17

17

20* 20*

25

20

TC

TECEflex

20

16

20

20*

25

20

Uponor

Unipipe

20

18

20

20*

20

20

Wirsbo-Velta

Rapex multi

20

16

20

20*

26

20

Woeste-Ysh.

Tectite

18

--

18

--

22

--

Woeste-Ysh.

Copper, press-fit

18

--

18

--

22

--

Viega

Profipress

18

--

18

--

22

--

Viega

Sanfix Fosta

16

16

20

20*

25

20

General

Copper, soldering

22

--

22

--

28

--

Remarks: 1. number „with fitting“ gives the max. outer pipe diameter usable for use of fittings. (system specific 90 °- angles / bends )

20

18 2. number „bent“ gives the max. pipe outer diameter which can be used with hand bending. (bending with spring, bending radius = 3 x pipe outer diameter). * = chiselling out recess on wall for outside corner (with hand bending with spring, bending radius = 3 x pipe outer diameter. (chiselling out recess is no longer necessary with bending radius < 2.5 x pipe outer diameter when using bending tool. Observe any instructions from pipe manufacturers!)

Skirting Board Profiles

g t

Be n

Fi tti n

g W ith

t

Fi tti n

g Be n

Fi tti n W ith

Aquatherm

Radiator Connection Systems

3

2

t

1

Manufacturer Name of system

Riser Sections

Which corner solution fits which pipe system?

The fittings and pipes from the various manufacturers have been tested in conjunction with installation of the HZ 2000 - System in 90° inner and outer corners. As of: January 2003. The table may not be complete. The details given here and in our overall documentation - including the illustrations - correspond to the information currently available to us and are, to the best of our knowledge, correct and reliable. However they do not constitute a binding guarantee of their properties. Such a guarantee can only be given for the standards of our own products. The user of these products must check, test and decide with all due care on their appropriateness for the intended use at their own risk. Our liability extends only to the extent given in our General Terms and Conditions. We reserve the right to make technical modifications. Hans Weitzel GmbH & Co. KG can as a rule only give the buyer support on technical user aspects. If you have any queries please contact us directly: +49 (0)6132- 790 890.

17

BLF

Dummy skirting board profiles of plastic hollow space profile

16

We recommend using dummy skirting profiles along walls without heating pipes. They consist of a robust plastic hollow space profile with a sealing lip to the wall and are available in eight finishes matching the skirting boards SLF 2000 up to 22 mm. The dummy skirting boards can be mounted easily with the dummy skirting board holder art. no.155. Dummy skirting board holders should be spaced every 50 cm. Dummy skirting board holders are mounted with the nail plug art. no. 204.

87

The moulded parts for the SLF profile illustrated below have a breaking piece on the underside. This means they can be used both as moulded parts for dummy skirting boards and also for transition from skirting board to dummy skirting board. We recommend cutting the breaking points off with a carpet knife or scissors. HZ Dummy skirting board holder art. no. 155 (BLH) Dummy skirting board holders for mounting BLF dummy skirting boards. The dummy skirting boards BLT and BL are mounted using only a screw without the dummy skirting board holder. Packing unit: 40 pces Number required: 2 per metre Nail plug art. no. 204 see page 19

Dimensions of BLF with BLH

Dummy skirting Inside corner for Outer corner for Butt joint board custom solutions custom solutions from plastic hollow space profile Packing unit: 40 m Length: 4 m

18

for BLF or transition from BLF to SLF Packing unit: 10 pces

for BLF or transition from BLF to SLF Packing unit: 10 pces

Packing unit: 10 pces

Left end piece

Right end piece

Packing unit: 10 pces

Packing unit: 10 pces

Maple Art. no. 2019 (BLF A)

Maple Art. no. 2016 (IE A)

Maple Art. no. 2017 (AE A)

Maple Art. no. 2013 (ST A)

Maple Art. no. 2014 (ES A left)

Maple Art. no. 2015 (ES A right)

Light beech Art. no. 2029 (BLF BH)

Light beech Art. no. 2026 (IE BH)

Light beech Art. no. 2027 (AE BH)

Light beech Art. no. 2023 (ST BH)

Light beech Art. no. 2024 (ES BH left)

Light beech Art. no. 2025 (ES BH right)

Dark beech Art. no. 4139 (BLF BD)

Dark beech Art. no. 4131 (IE BD)

Dark beech Art. no. 4132 (AE BD)

Dark beech Art. no. 4133 (ST BD)

Dark beech Art. no. 4134 (ES BD left)

Dark beech Art. no. 4135 (ES BD right)

White ash Art. no. 4149 (BLF EW)

White ash Art. no. 4141 (IE EW)

White ash Art. no. 4142 (AE EW)

White ash Art. no. 4143 (ST EW)

White ash Art. no. 4144 (ES EW left)

White ash Art. no. 4145 (ES EW right)

Light oak Art. no. 169 (BLF EH)

Light oak Art. no. 161 (IE EH)

Light oak Art. no. 162 (AE EH)

Light oak Art. no. 163 (ST EH)

Light oak Art. no. 164 (ES EH left)

Light oak Art. no. 165 (ES EH right)

Dark oak Art. no. 179 (BLF ED)

Dark oak Art. no. 171 (IE ED)

Dark oak Art. no. 172 (AE ED)

Dark oak Art. no. 173 (ST ED)

Dark oak Art. no. 174 (ES ED left)

Dark oak Art. no. 175 (ES ED right)

White Art. no. 189 (BLF W)

White Art. no. 181 (IE W)

White Art. no. 182 (AE W)

White Art. no. 183 (ST W)

White Art. no. 184 (ES W left)

White Art. no. 185 (ES W right)

Grey Art. no. 199 (BLF G)

Grey Art. no. 191 (IE G)

Grey Art. no. 192 (AE G)

Grey Art. no. 193 (ST G)

Grey Art. no. 194 (ES G left)

Grey Art.-no . 195 (ES G right)

Dummy skirting board for carpets and dummy skirting board made of solid wood

BLT: The carpet dummy skirting boards are used along walls where no pipes have been laid. The carpet dummy skirting board BLT is made of a robust plastic hollow space profile and is provided with self-adhesive tape for inserting the carpet.

15

The dummy skirting boards are mounted with the nail plug art. no. 204. The screw head is covered by the carpet once it is stuck down. Dummy skirting board holders are unnecessary. Precise mitre cuts are needed in the corners. No moulded parts are needed due to the shallow depth.

BL: Solid wood dummy skirting boards are available in two finishes matching the solid wood and wood-based material skirting boards (see page 15), in abachi solid wood (unfinished, can be stained) and genuine wood veneer in light oak. To obtain a better appearance a brass cheese head screw and wall plug should be used for mounting.

Dimensions of BLT

Precise mitre cuts are needed in the corners. In order to obtain an accurate mitre cut we offer our mitre cutting device or precision saw. 13

Radiator Connection Systems

The self-adhesive tape is only suitable for carpets with a smooth foam coating. With other carpeting extra contact adhesive or double-sided adhesive tape is necessary.

Carpet depth: 80 mm

7

87

The profile is available in the finishes light oak and white matching the SLT 2000 profile (see pages 10 and 11).

Skirting Board Profiles

BLT / BL

85

Wall plug with countersunk head and threaded nail. Packing unit: 50 pces Requirements: 1 per 50 cm

Carpet dummy skirting board

With self-adhesive tape, to match SLT 2000. Packing unit: 40 m Length: 4 m (Installation without BLH)

Wood dummy skirting board

HZ dummy skirting board in solid abachi wood Packing unit: 40 m Length: 4 m

Dimensions of BL

Light oak Art. no. 269 (BLT EH)

Natural, can be stained Art. no. 158 (BL A)

White Art. no. 289 (BLT W)

Genuine oak veneer Art. no. 159 (BL EH)

Riser Sections

Nail plug art. no. 204 (ND 40-6)

19

Accessories for skirting boards

The HZ 2000 brackets art. nos. 2150, 2250, 2151 and 2152 are supplied together with the slides. If a slide is misplaced you can order a spare slide art. no. 2001 separately. The notching pliers and the cover strip, together with the HZ plastic skirting boards, make finishing work to the HZ radiator connections fast and neat. Use the flexible, self-adhesive sealing lip to extend the HZ profiles by 10 mm towards the floor or the wall, which enables you to compensate for unevenness in the wall or floor. Apart from heat insulation the insulation hose will also reduce noise in prewall installation of pipework. Use of the precision mitre saw or the mitre cutting device will enable you to achieve an exact mitre cut.

HZ 2000 spare slide

Suitable for all HZ 2000 brackets (except SCH 2450) Packing unit: 40 pces

Art. no. 2001 (S 2001)

Notching pliers For making recesses in skirting boards for the HZ radiator connection quickly and neatly

Art. no. 9150 (AKZ)

Cover strip For covering the recess for the HZ radiator connection in the skirting board Packing unit: 25 pces

Precision mitre saw

Flexible, self-adhesive For perfect cutting sealing lip for extending with all HZ profiles the skirting board along the wall and towards the floor Length: 4 m

Mitre cutting device

Suitable for cutting all HZ profiles

Insulation hose

Packing Film

Roll: 20 m length

PE, transparent 1 Roll = 100 m length Hose width: 50 cm

Maple Art. no. 1310 (AB A)

Dark beech Art. no. 2138 (DLW BD)

Light beech Art. no. 1320 (AB BH)

Light oak/light beech Art. no. 2168 (DLW EH)

18-4-26 for Ø 18* Art. no. 1918 (DS 18)

Dark beech Art. no. 1330 (AB BD)

Dark oak Art. no. 2178 (DLW ED)

22-4-30 for Ø 22* Art. no. 1922 (DS 22)

Light oak Art. no. 1360 (AB EH)

White/white ash Art. no. 2188 (DLW W)

Dark oak Art. no. 1370 (AB ED)

Grey Art. no. 2198 (DLW G)

* for DS 15 use bracket 2150 or 2250 ; for DS 18 und DS 22 use bracket 2450

White Art. no. 1380 (AB W)

20

Sealing lip

Grey Art. no. 1390 (AB G)

Art. no. 147 (GS)

Art. no. 146 (GSL)

15-4-23 for Ø 15* Art. no. 1915 (DS 15)

Packing film Art. no. 9148 (VF)

90° elbow with shut-off valve and 90° bend Pages 28 - 29

Radiator connection Pages 22 - 27

Skirting Board Profiles Radiator Connection Systems

Compression joint Page 29

Riser Sections

The easy and complete way to connect radiators

21

HKU - Radiator connections for soldering Radiator connection, single-piece, for soldering art. no. 1315R/1315L/1318R/1318L 50 26

1/2''

da

70

~13

35

(R)

>15

di

(L) 117

Type HKU-E 15LR HKU-E 18LR

Art. no. 1315R 1318R

di 15 18

da 18 22

Valve right right

HKU-E 15LL HKU-E 18LL

1315L 1318L

15 18

18 22

left left

Radiator connection, two-piece, for soldering art. no. 1415/1418 1/2''

~25,5

35

di

da

70

~13

Type HKU 15 HKU 18

Art. no. 1415 1418

>15

194

di 15 18

da 18 22

Radiator connection, two-piece, for soldering art. no. 1015/1018 ~25,5

1/2"

Type HKU 15 L HKU 18 L

Art. no. 1015 1018

di 15 18

>15

59

da

di

35

70

~13

da 18 22

IMPORTANT for all HZ radiator connections for soldering: The upper pipe is the forward flow. The lower pipe is the backflow. When using the HZ skirting board profiles the following minimum clearances must be observed between the connection thread of the radiator and the finished floor level: When using SLF, SLT and SLHW* - at least 160 mm When using SLF 28-2000 - at least 180 mm When using SLL - at least 190 mm 22

*When using SLHW only the single-piece radiator connection (DN 15 and DN 18) can be used. For braze joints we recommend Braze Tec Flussmittel Degussa h and Braze Tec Hartlot Degussa 4576. If expansion of the pipes without stress is not possible, standard commercial expansion joints should be used.

No need for chiselling out recess on wall, made of brass, for copper pipes, suitable for AWA-E, AWA and PBV

No need for chiselling out recess on wall, made of brass, for copper pipes, suitable for AWA-E, AWA and PBV

di=15mm da=18mm Art. no. 1315 R (HKU E 15 LR)

di=15mm da=18mm Art. no. 1315 L (HKU E 15 LL)

di=18mm da=22mm Art. no. 1318 R (HKU E 18 LR)

di=18mm da=22mm Art. no. 1318 L (HKU E 18 LL)

Due its flat back there is no need for chiselling out a recess in the wall. Valve group at the lower right of the radiator. Valve group at the lower left of the radiator.

Use art. no. 1315R or 1318R Use art. no. 1315L or 1318L

The single-piece radiator connection is the only HZ radiator connection which can also be worked with the wood-based material skirting board SLHW. Remove the centre ridge using pliers!

HKU two-piece for soldering

The two-piece HZ brass radiator connection is suitable for soldering with copper pipes. It can be used both for the right and the left-hand radiator connection. Due its flat backflow there is no need for chiselling out a recess in the wall.

No chiselling out of recess in wall, can be used on right and on left, brass, suitable for AWA-E, AWA, PBV and PBV-L

di=15mm da=18mm Art. no. 1415 (HKU 15 ) di=18mm da=22mm Art. no. 1418 (HKU 18 )

HKU two-piece for soldering

The two-piece HZ brass radiator connection is suitable for soldering with copper pipes. It can be used both for the right and the left-hand radiator connection.

Brass, for copper pipes, suitable for AWA-E, AWA, PBV and PBV-L

Skirting Board Profiles

The single-piece HZ brass radiator connection is suitable for soldering with copper pipes. It is used for valve compact radiators with connection on bottom left or right and a 50 mm spacing between forward and backflow.

HKU singlepiece, left

Radiator Connection Systems

HKU singlepiece, right

di=15mm da=18mm Art. no. 1015 (HKU 15 L)

The simplest method of making the recess in the skirting board is to use our notching pliers (art. no.9150). For an attractive finish we recommend cover strips in the matching décor (refer to page 20). These can be fitted or stuck over the recess. We offer various alternatives for fitting the radiator connection to the radiator using a 90° elbow with shut-off valve or a 90° bend, as on pages 28/29.

NOTE min. 160 mm from finished floor level to connection thread

di=18mm da=22mm Art. no. 1018 (HKU 18 L) min. 55 max. 145

min. 40 max. 100

The HKU is suitable for: copper pipes

Riser Sections

At the junction of forward and backflow chisel out a recess in the plaster about 15mm deep and about 30mm wide for the radiator connection.

min. 160 max. 235 min.120 max.135

23

HKU - Radiator connections for press-fitting Radiator connection, two-piece for copper press-fitting art. no. 1445/1448 ~25,5

1/2''

>15

35

di

70

~13

~255

Type HKU U 15 VP HKU U 18 VP

Art. no. 1445 1448

di 15 18

Radiator connection, two-piece for copper press-fitting art. no. 1515/1518 ~29

1/2"

>15

35

70

~14

di

96

Type HKU 15 VP HKU 18 VP

Art. no. 1515 1518

di 15 18

Radiator connection, two-piece for press-fitting art. no. 1465/1468

~25,5

1/2''

>15 35

di

70

~13

~245

Type HKU U 15 M HKU U 18 M

Art. no. 1465 1468

di 15 18

IMPORTANT for all HZ radiator connections for press-fitting:

24

The upper pipe is the forward flow. The lower pipe is the backflow.

When using SLF and SLT When using SLF 28-2000 When using SLL

- at least 160 mm - at least 180 mm - at least 190 mm

When using HZ skirting board profiles the following clearances must be observed between the connection thread of the radiator and the finished floor level:

If expansion of the pipes without stress is not possible, standard commercial expansion joints should be used.

No need for chiselling out recess in wall, can be used on left and right, HKU brass with Viega red brass contour, suitable for AWA-E, AWA, PBV and PBV – L

The two-piece brass HZ radiator connection for copper press-fitting is suitable for the Viega ‘profipress’ system. It can be used both for the right and the left-hand radiator connection. Due its flat backflow there is no need for chiselling out a recess in the wall.

di=15mm Art. no. 1445 (HKU U 15 VP)

Skirting Board Profiles

HKU two-piece for copper press-fitting

HKU two-piece for copper press-fitting

The two-piece red brass HZ radiator connection for copper press-fitting is suitable for the Viega ‘profipress’ System. It can be used both for the right and the left-hand radiator connection.

Red brass, for Viega ’profipress‘ system, suitable for AWA-E, AWA, PBV and PBV-L

At the junction of the forward and backflow chisel out a recess in the plaster about 15 mm deep and about 30 mm wide for the radiator connection.

di=15 mm Art. no. 1515 (HKU 15 VP) di=18 mm Art. no. 1518 (HKU 18 VP)

HKU two-piece mapress pressfitting system

The two-piece HZ brass radiator connection for press-fitting is suitable for the mapress press-fitting system. It can be used both for the right and the left-hand radiator connection.

No need for chiselling out recess in wall, can be used on left and right, HKU brass with mapress red brass contour, suitable for AWA-E, AWA, PBV and PBV – L

Radiator Connection Systems

di=18mm Art. no. 1448 (HKU U 18 VP)

di=15mm Art. no. 1465 (HKU 15 M)

The simplest method of making the recess in the skirting board is to use our notching pliers (art. no.9150). For an attractive finish we recommend cover strips in the matching décor (refer to page 20). These can be fitted or stuck over the recess. We offer various alternatives for fitting the radiator connection to the radiator using a 90° elbow with shut-off valve or 90° bend, as on pages 28/29.

NOTE min. 160 mm from finished floor level to connection thread

di=18mm Art. no. 1468 (HKU 18 M) min. 55 max. 145

min. 40 max. 100 min. 160 max. 235 min.120 max.135

The HKU is suitable for: copper pipes

Riser Sections

Due its flat backflow there is no need for chiselling out a recess in the wall.

galvanised steel pipes

25

HKU – radiator connections with tapered seal, Two-piece radiator connection with 3⁄4” male thread/tapered seal art. no. 1434 1/2''

~25,5

da= 3/4''

>15 35

70

~13

194

Type HKU 3/4E

Art. no. 1434

da 3/4“

Two-piece radiator connection with 1/2” female thread art. no. 1412

~25,5

1/2''

di= 1/2''

>15 35

70

~13

194

Type HKU 1/2 I

Art. no. 1412

di 1/2“

Radiator connection, two-piece for copper push-fitting art. no. 1455/1458 ~25,5

1/2"

~233

Type HKU U 15 CF HKU U 18 CF

Art. no. 1455 1458

>15 35

di

70

~13

di 15 18

IMPORTANT for all radiator connections with tapered seal / female thread / for push-fitting:

26

The upper pipe is the forward flow. The lower pipe is the backflow.

When using SLF and SLT When using SLF 28-2000 When using SLL

- at least 160 mm - at least 180 mm - at least 190 mm

When using HZ skirting board profiles the following clearances must be observed between the connection thread of the radiator and the finished floor level:

If expansion of the pipes without stress is not possible, standard commercial expansion joints should be used.

For composite pipes, no chiselling out of recess in wall, can be used on right and on left, brass, suitable for AWA-E, AWA, PBV and PBV-L

Due its flat backflow there is no need for chiselling out a recess in the wall.

f. adaptor union da= 3/4“ male thread / tapered seal Art. no. 1434 (HKU 3/4 E)

HKU two-piece, 1⁄2” female thread

The two-piece HZ brass radiator connection is suitable for adaptor unions with 1⁄2” female thread. It can be used both for the right and the left-hand radiator connection.

No chiselling out of recess in wall, can be used on right and on left, brass, for adapter union, suitable for AWAE, AWA, PBV and PBV-L

Due its flat backflow there is no need for chiselling out a recess in the wall.

di=1/2“ Art. no. 1412 (HKU 1/2 I)

HKU two-piece for copper push-fitting

The two-piece HZ brass radiator connection for copper push-fitting is suitable for Cuprofit push-fit systems. Only DIN EN 1057 and RAL 641/1 tested copper pipe may be used. It can be used both for the right and the left-hand radiator connection.

No chiselling out of recess in wall, can be used on right and on left, brass, for Cuprofit push-fit system, suitable of AWA-E, AWA, PBV and PBV-L

Skirting Board Profiles

The two-piece HZ brass radiator connection with 3⁄4” male thread/tapered seal is suitable for composite pipes. The pipe is connected with an adaptor union fitting the 3⁄4” male thread/tapered seal from the relevant pipe manufacturer. It can be used both for the right and the left-hand radiator connection.

HKU, two-piece with 3⁄4” male thread/tapered seal

Radiator Connection Systems

female thread and for copper push-fitting

Due its flat backflow there is no need for chiselling out a recess in the wall.

The simplest method of making the recess in the skirting board is to use our notching pliers (art. no.9150). For a more attractive finish we recommend cover strips in the matching décor (refer to page 20). These can be fitted or stuck over the recess. We offer various alternatives for fitting the radiator connection to the radiator using a 90° elbow with shut-off valve or 90° bend, as on pages 28/29.

NOTE min. 160 mm from finished floor level to connection thread

1. Cut the copper system pipe to length using a pipe cutter. 2. Trim the end of the pipe carefully and calibrate with pin and ring. 3. Mark the insert depth for the push-fitting. 4. Slip the push-fitting onto the pipe as far as the marking. 5. With soft copper pipe use appropriate support sleeves.

di=15mm Art. no. 1455 (HKU U 15 CF) di=18mm Art. no. 1458 (HKU U 18 CF)

min. 55 max. 145

min. 40 max. 100

Riser Sections

Observe the following steps in installation:

min. 160 max. 235 min.120 max.135

27

AWA

the fast and flexible connection between the HZ radiator connector and compact radiator with integrated valve

90° elbow with shut-off valve, can be shut off/drained 90° elbow with shut-off valve, can be drained, nickel plated

90° elbow with shut-off valve, nickel plated

Made of copper pipe with compression joint 1⁄2”, Ø 15 mm, for connection between HZ HKU and compact radiator with integrated valve, nickel plated, no. required: 1 pair/HZ radiator connection

Made of copper pipe with compression joint 1⁄2”, Ø 15 mm, for connection between HZ HKU and compact radiator with integrated valve, nickel plated, no. required: 1 pair/HZ radiator connection

• • • • • • • •



art. nos. 1022/1023

can be shut off can be drained ( art no. 1023) 15 mm copper pipe, nickel plated fits all HZ radiator connections Length: 125 mm Height: 100 mm can be trimmed to required height and depth incl. compression joint to the radiator connector compression joint between 90° elbow and the radiator art. nos. 1025 / 1026 see page 29 Cock block not required

Art. no. 1022 (AWA)

Art. no. 1023 (AWA-E)

min. 55 max. 145

min. 40 max. 100 min. 160 max. 235 min.120 max.135

Note: min. 160 mm from finished floor level to connection thread

90° elbow with shut-off valve, can be shut off/ long art. no. 1022L • • • •

90° elbow with shut-off valve long, nickel plated Made of copper pipe with compression joint 1⁄2”, Ø 15 mm, length of the pipe sockets: 150 mm, for connecting HZ HKU and compact radiator with integrated valve. no. required: 1 pair/HZ radiator connection

• • •



can be shut off 15 mm copper pipe, nickel plated fits all HZ radiator connections Length: 150 mm Height: 150 mm can be trimmed to required height and depth incl. compression joint to the radiator connector compression joint between 90° elbow and the radiator art. nos. 1025 / 1026 see page 29 Cock block not required

min. 55 max. 170

min. 40 max. 150 min. 160 max. 285

min. 120 max. 135

Art. no. 1022L (AWA-L) Note: min. 160 mm from finished floor level to connection thread

Adjustment of flow rate for art. nos. 1022, 1023 und 1022L dp [bar] 1

flow restrictor [m3/h]: 0,42

1

2

3

0,71 0,94 1,29 1,66 2,07 2,46

4

5

6

Turns of adjusting nipple

7

0,1

0,01 50

28

100

500

1000

2000 3000 Flow [l/h]

5000

1

2,5 turns

2

3,5 turns

3

4,5 turns

4

5,5 turns

5

6,5 turns

6

7,5 turns

7

8,5 turns

The following applies to all HZ compression joints: tighten the union nut as far as possible by hand and then one more turn max. using a spanner.

Made of copper pipe with compression joint 1⁄2”, Ø 15 mm, for connection between HZ HKU and compact radiator with integrated valve No. required: 1 pair/HZ radiator connection

• 15 mm copper pipe, nickel plated • fits all HZ radiator connections • Length: 115 mm Height: 72 mm • can be trimmed to required height and depth • incl. compression joint to the radiator connector • compression joint between 90° bend and the radiator art. nos. 1025 / 1026 see below • Cock block not required

min. 65 max. 130

min. 40 max. 70 min. 160 max. 205 min.120 max.135

Note: min. 160 mm from finished floor level to connection thread

Art. no. 1021 (PBV)

90° bend art. no. 1031 90° bend, long, chromium plated Made of precision steel tube with compression joint 1⁄2”, Ø 15 mm, for radiators with lateral connection using HZ HKU two-piece, no. required:1 pair/HZ radiator connection

Art. no. 1031 (PBV-L)

• 15 mm precision steel tube, chromium plated • Length: Forward flow 1000 mm Backflow 72 mm Height: Forward flow

120 mm

Backflow

min. 65 max. 130

115 mm

• can be trimmed to required height and depth • forward flow with thermostat head and backflow must be valve in axial or angular form with locking ring for 15 mm Ø • incl. compression joint to the radiator connector

min. 40 max. 1000 min. 160 max. 1135

• 90° bend 1031 for fitting two-piece, flat radiator connections (14XX) can only be used with composite pipes up to 20 mm Ø or with copper pipes up to 18 mm Ø • compression joint between 90° bend and the radiator art. nos. 1025 / 1026 see below • Cock block not required

min.120 max.135

Note: min. 160 mm from finished floor level to connection thread

Compression joint for connecting AWA and PBV to the radiator Compression joint art. no. 1026 (KVI) With self-sealing double nipple for fitting 90° bend (PBV) or 90° elbow with shut-off valve (AWA-E, AWA) and the compact radiator with integrated valve with 1⁄2” female thread, nickel plated, package quantity: 10 pces

Compression joint art. no. 1025 (KVA)

Skirting Board Profiles

90° bend art. no. 1021 90° bend nickel plated

Radiator Connection Systems

the fast and flexible connection between the HZ radiator connector and compact radiator with integrated valve

Riser Sections

PBV

for connecting 90° bend (PBV) or 90° elbow with shut-off valve (AWA-E, AWA) and compact radiator with integrated valve with 3/4” male thread, nickel plated, package quantity: 10 pces

Compression joint 15 x 1⁄2“ art. no. 1034 (KV 15) To fit the top connector for all HZ radiator connections, for CU and soft steel pipes, Ø 15 mm, nickel plated, package quantity: 10 pces

29

STK

Riser unions

HZ riser unions allow you to save both space and time in installation for the transition from horizontal to vertical copper pipes. This convincing and inexpensive solution in red brass for soldering is available in four different sizes. This is where multi-storey pipe distribution is made easy!

70

Hda

For cladding junctions we recommend using the riser sections art. no. 980 and 6580 (see page 31).

a Vdi

Vda

c

b

Hdi

70

If expansion of the pipes without stress is not possible, standard commercial expansion joints should be used.

Specifications in mm Art.no. 12215 12218 12815 12818

Vertical Vdi Vda 22 28 22 28 28 35 28 35

Horizontal Hdi Hda 15 18 18 22 15 18 18 22

a 52 52 69 69

b 36 36 50 50

c 25 25 37 37

Riser union

Riser union

Riser union

Riser union

from red brass, for soldering Diameter: vertical ID=22mm / OD=28mm horizontal ID=15mm / OD=18mm

from red brass, for soldering Diameter: vertical ID=22mm / OD=28mm horizontal ID=18mm / OD=22mm

from red brass, for soldering Diameter: vertical ID=28mm / OD=35mm horizontal ID=15mm / OD=18mm

from red brass, for soldering Diameter: vertical ID=28mm / OD=35mm Horizontal ID=18mm / OD=22mm

Art. no. 12215 (STK 22/15 L)

30

Art. no. 12218 (STK 22/18 L)

Art. no. 12815 (STK 28/15 L)

Art. no. 12818 (STK 28/18 L)

Riser section, plastic, U-shaped

The U-shaped HZ riser sections are robust, plastic hollow space profiles, which have been dyed white all the way through (similar to RAL 9010). They are three metres long and are available in four different sizes.

114 100 7

Dimensions of STP U art. no. 780

50 x 100 mm

When laying riser sections on the ceiling, it is essential that wall plugs and screws are also used to attach the section as a safety measure.

164 150 82 75

7

Dimensions of STP U art. no. 880

75 x 150 mm

Nail plug art. no. 204 (ND 40-6) 214 200

107 100

Wall plug with countersunk head and threaded nail. Packing unit: 50 pces Requirements: 2 pces. per mounting bracket

Plastic hollow space profile, white, length:3 m Packing unit: 24 m

7

Mounting bracket HZ end cover For U-shaped riser HZ plastic end cover section for STP U Requirements: 2 pces/metre Packing unit: 40 pces

Dimensions of STP U art. no. 980

100 x 200 mm

Internal dimensions 50x100 mm

Art. no. 780 (STP 50-100)

Internal dimensions 75x150 mm

Art. no. 880 (STP 75-150)

Internal dimensions 100x200 mm

Art. no. 980 (STP100-200)

Internal dimensions 150x250 mm

Art. no. 6580* (STP150-250)

*With art. no. 6580 packing unit: 6 m in box

for STP 50-100 Art. no. 78 (BFK 100)

for STP 50-100 Art. no. 784 (ES STP 100)

for STP 75-150 Art. no. 889 (BFK 150)

for STP 75-150 Art. no. 884 (ES STP 150)

for STP 100-200 Art. no. 989 (BFK 200)

for STP 100-200 Art. no. 984 (ES STP 200)

157 150

264 250

7

Dimensions of STP U art. no. 6580

Riser Sections

U-shaped riser section

Radiator Connection Systems

The HZ riser sections are very versatile in application. They can be used both for cladding vertical heating pipes and also for concealing water pipes. In this case the pipes can be provided with heat insulation. Use the HZ riser sections to conceal pipes on ceilings quickly and easily!

57 50

The riser sections are mounted with matching mounting brackets, which are spaced approximately every 50 cm. Nail plugs, art. no. 204, are used to attach the brackets.

Skirting Board Profiles

STP U

150 x 250 mm

for STP 150-250 Art. no. 6589 (BFK 250)

31

STP L

Riser section, plastic, L-shaped

The L-shaped HZ riser sections are robust, plastic hollow space profiles, which have been dyed white all the way through (similar to RAL 9010). They are three metres long and are available in three different sizes.

82 75

164 157

The riser sections are mounted with matching mounting brackets, which are spaced approximately every 50 cm. Nail plugs, art. no. 204, are used to attach the brackets.

7

Dimensions of STP L art. no. 6280

75 x 150 mm

Four mounting brackets art. no. 989 are required per metre to install the riser section art. no. 6480.

214 207

107 100

They are intended for cladding pipes laid in corners in particular. In this case the pipes can also be provided with heat insulation. They can also be used as skirting board profiles for larger pipes.

7

Dimensions of STP L art. no. 6380

100 x 200 mm

Nail plug art. no. 204 (ND 40-6) Wall plug with countersunk head and threaded nail. Packing unit: 50 pces Number required: 2 pces. per mounting bracket

214 207

214 207

L-shaped riser section

White plastic hollow space profile, length: 3 m, packing unit: 24 m in box

7

Dimensions of STP L art. no. 6480

Mounting bracket

For L-shaped riser section Number required: 2 pces/metre Packing unit: 40 pces

200 x 200 mm

Internal dimensions 75x150mm

Art. no. 6280 (STP L 75-150)

Internal dimensions 100x200 mm

Art. no. 6380 (STP L 100-200)

Internal dimensions 200x200 mm

Art. no. 6480 (STP L 200x200)

for STP L 75-150 Art. no. 6289 (BFK L 75-150) for STP L 100-200 Art. no. 6389 (BFK L 100-200) for STP L 200-200 2x Art. no. 989* (BFK 200) *4 pces per metre required

32

for STP 6480

Nail plug art. no. 204 (ND 40-6) Wall plug with countersunk head and threaded nail. Packing unit: 50 pces. Number required: 2 pces. per mounting bracket

Riser rosette art. no. 6081 (STR 18) For pipe outlets at the side of riser sections, suitable for pipes up to 18 mm

Riser rosette art. no. 6082 (STR 22) For pipe outlets at the side of riser sections, suitable for pipes up to 22 mm

Flexible sealing lip art. no. 6088 (DLW) For sealing the STP on the wall, white, self-adhesive, length: 3 m, packing unit: 48 m

Skirting Board Profiles

Accessories for riser sections

Radiator Connection Systems

Accessories

Butt joint cover section art. no. 6078 (ST STP) For all HZ riser sections, white, self-adhesive, length: 1 m, packing unit: 25 m

Sheet steel, for installing in STP no. 980, 6380, 6480, 6580, white

Inspection door 15 x 20 cm art. no. 6028 (RT 15-20) Sheet steel, for installing in STP no. 980, 6380, 6480, 6580, white

Inspection door 15 x 25 cm art. no. 6038 (RT 15-25)

Riser Sections

Inspection door 15 x 15 cm art. no. 6018 (RT 15-15)

Sheet steel, for installing in STP no. 980, 6380, 6480, 6580, white

HZ lifting tool art. no. 9151 (AW) For removing HZ riser sections

33

+49 (0) 6132 / 78 36 21

Fax reply to Hans Weitzel GmbH & Co. KG Ingelheim am Rhein

Request for Promotional Material

or download from: http://www.hz-weitzel.de

Please send us free of charge and without obligation: HZ sample box incl. HZ Main Catalogue HZ Price List HZ Installation Instructions HZ End Consumer Folder

Sample of art. no.

We want more! We would like ........... Visit by representative from sales force Telephone consultation

(Please complete missing information in capitals in dark-coloured ink, if this is not included in your firm‘s stamp.) Customer reference: Company: Attn / Position: Street no.: Postal code City: Country: Language for correspondance: Tel.: Fax.: Email: 34

Date: We are a Plumbing and fitting company Wholesaler Educational institution End consumer Property company Planner Other

Since the company was founded in 1963 the idea of pipe cladding for pre-wall installation has given rise to an all-round package for heating and piping. Nowadays our family business which is rich in tradition presents itself as a system provider for pre-wall installation with three product groups. Apart from the skirting board profiles developed by Hans Weitzel we also offer the HZ riser sections for vertical pipe cladding and the HZ connector groups for fitting radiators. Over the past decades HZ has proven its spirit of innovation again and again. The range of HZ 2000 Skirting Boards was launched on the market a while back. The advantages in installation, typical of HZ, have been further improved on. Our modern production sites are in Ingelheim am Rhein, about 60 km south west of Frankfurt am Main. This is where our high-quality products are manufactured under constant quality control in state-of-the-art production sites in round-the-clock operation. Environmentally friendly production is a particularly high priority here. Service for our customers in the western states of Germany and abroad is managed at our headquarters in Ingelheim, to which a modern logistics centre is attached. Our customers in the eastern part of Germany, the new states, are served by our branch founded in 1997 in Radefeld near Leipzig. The export department has been expanded in order to meet the demand stemming from an increasing presence in foreign markets. Sales of our products are handled via trade wholesalers and guarantee you prompt availability.

Hans Weitzel GmbH & Co. KG Konrad-Adenauer-Straße 20 D-55218 Ingelheim Export: Tel.:

+49 (0) 61 32 / 790 89- 10

Tel.:

+49 (0) 61 32 / 790 89- 12

Fax:

+49 (0) 61 32 / 78 36 - 10

Fax:

+49 (0) 61 32 / 78 36 - 12

e-mail: [email protected]

www.hz-weitzel.de

View more...