Gen2 Regen Upgrade Xizi Xizi Otis, Otis, April April 20 2010 10

1

Summary •

Gen2 Regen ≤1000kg,1.7 1000kg,1.75m/s 5m/s configuration upgrade  –  –  –  –



Controller and drive upgrade to ACD2 MRL E&I panel change change to mini size Introduce OTIS PM door door operator NGSOK as Standard Standard door operator operator Layout changes changes accordingly accordingly

Gen2 Regen extended to 2000kg, 1.75m/s  – Added Regen Regen function to 1150~2000kg 1150~2000kg as standard  – Introduced Otis optimized optimized Gen2 machine machine  – Introduced OTIS E3 qualified qualified HN6000 HN6000 progressive safety  – Other configuration configuration (Controller& drive, E&I panel, door operator) operator) as per Gen2 Regen Regen ≤1000kg



Gen2 (1150~2000kg up to 1.75m/s,Non-regen) completely phase out Note: Gen2 Regen up to 2000kg is officially sales release on April 1st 2010 and Gen2 sales phase out at the same time

Configuration Upgrade 

Gen2 Regen

≤1000kg configuration upgrade



Gen2 Regen extended to 2000kg to replace GeN2

Machine Upgrade

GeN2

GeN2-Regen 

ABA20220AS

ABA20220BD Apply to 1150kg to 2000kg Gen2 Regen only - OTIS optimized Gen2 Machine from the same supplier as GeN2 - Noise and vibration performance is improved - Otis Optimized Gen2 machine for ≤1000kg will be introduced later once it’s available

Controller Upgrade

GeN2-Regen 

GeN2  &Previous Gen2 Regen up to 1000kg -OTIS global new controller for MRL product -More compact - OH-CONB604B MRL will be phase out

OH-CON4424 (For GeN2) OH-CONB604MRL(for previous Gen 2 Regen up to 1000kg)

ACD2-MRL Controller Apply to 630kg to 2000kg Gen2 Regen

Regen function is added GeN2 &Previous Gen2 Regen up to 1000kg

GeN2-Regen 

-OTIS global integrated regen drive for MRL - More compact - OH-CONB604B MRL will be phase out Non-Regen drive(OH-CON4424) Otis Regen drive for previous Gen2 Regen up to 1000kg

ACD2 MRL regen drive Apply to 630kg to 2000kg Gen2 Regen

E&I PANEL Upgrade

GeN2  & Previous Gen2 Regen up to 1000kg

 

GeN2-Regen 

Min E&I PANEL Apply to 630kg to 2000kg Gen2 Regen

Door Operator upgrade

GeN2 

 

GeN2-Regen 

&Previous Gen2 Regen up to 1000kg

Apply to 630kg to 2000kg Gen2 Regen STD: AT120

STD: NGSOK - NGSOK is OTIS global PM operator - DO2000 is still optional

Safety Gear Upgrade

GeN2 

STD:9672D/E

 

GeN2-Regen 

STD:HN6000B/C

Apply to 1150kg to 2000kg only

- HN6000B/C are OTIS global E3 safety components - Bigger running clearance. Ride quality is improved and false tripping is eliminated - 9672D/E are still optional

Layout Changes

New Controller & Drive Architecture Previous Gen2 Regen (OH-CONB604MRL controller) 

GeN2-Regen (ACD2 MRL)

GeN2(OH-CON4424 Controller) 

 k g  0  0  2 0 ~  g  k  6 3 0

New arrangement is easier for controller and drive inspection

E&I PANEL cutout size

GeN2 

 

GeN2-Regen  Apply to 630kg to 2000kg Gen2 Regen

Top floor  Min E&I PANEL size reduced, the cutout 1600(H)x250(W).

New Bracket Spacing for top floor GeN2 

 

Gen2-Regen 

Apply to 630kg to 2000kg Gen2 Regen Top floor brackets -Stronger rail bracket made machine more stable - Noise and vibration is improved

Back up

ACD2 MRL Introduction

PRODUCT DESCRIPTION 

Integrated Regen controller

Improve

aesthetics and performance

OTIS

WWE (World Wide Engineering) lead design

OTIS

global source and SSI management

Drive

E&I Panel 210W x 540H x 90D

Controller 320W x1300H x 160D

Duty Table

Controller Operational Parameters Feature

Values

Feature

Values

Baseline Product

GCS -EN

Max Speed (m /s)

1.75

Operation Control

Max 8 Car Group

Max Duty (kg)

2000

Maximum # of Stops

24

Maximum # of Opening

32

Drive Door

OVFR2B-402,403,404, OVFR1A-406 NGSOK/AT120/AT400  /DO2000

LWD

Analog LWD

Service Tool

OTIS SVT

Machine

Opt. GeN2

Rescue operation

MRO*

Position Reference Photo-sensor 75 Max Rise (m)

Note: MRO function is standard. ARO function should be offered as an optional function after June 2010.

Performance Parameter

Target

Min. Floor Distance (mm)

350 @ 1.0m/s 500 @ 1.5m/s ~1.75m/s

Max Floor Distance (m)

11

Maximum Acceleration (PMT measurement: m/s2)

View more...