Controller and drive upgrade to ACD2 MRL E&I panel change change to mini size Introduce OTIS PM door door operator NGSOK as Standard Standard door operator operator Layout changes changes accordingly accordingly
Gen2 Regen extended to 2000kg, 1.75m/s – Added Regen Regen function to 1150~2000kg 1150~2000kg as standard – Introduced Otis optimized optimized Gen2 machine machine – Introduced OTIS E3 qualified qualified HN6000 HN6000 progressive safety – Other configuration configuration (Controller& drive, E&I panel, door operator) operator) as per Gen2 Regen Regen ≤1000kg
•
Gen2 (1150~2000kg up to 1.75m/s,Non-regen) completely phase out Note: Gen2 Regen up to 2000kg is officially sales release on April 1st 2010 and Gen2 sales phase out at the same time
Configuration Upgrade
Gen2 Regen
≤1000kg configuration upgrade
Gen2 Regen extended to 2000kg to replace GeN2
Machine Upgrade
GeN2
GeN2-Regen
ABA20220AS
ABA20220BD Apply to 1150kg to 2000kg Gen2 Regen only - OTIS optimized Gen2 Machine from the same supplier as GeN2 - Noise and vibration performance is improved - Otis Optimized Gen2 machine for ≤1000kg will be introduced later once it’s available
Controller Upgrade
GeN2-Regen
GeN2 &Previous Gen2 Regen up to 1000kg -OTIS global new controller for MRL product -More compact - OH-CONB604B MRL will be phase out
OH-CON4424 (For GeN2) OH-CONB604MRL(for previous Gen 2 Regen up to 1000kg)
ACD2-MRL Controller Apply to 630kg to 2000kg Gen2 Regen
Regen function is added GeN2 &Previous Gen2 Regen up to 1000kg
GeN2-Regen
-OTIS global integrated regen drive for MRL - More compact - OH-CONB604B MRL will be phase out Non-Regen drive(OH-CON4424) Otis Regen drive for previous Gen2 Regen up to 1000kg
ACD2 MRL regen drive Apply to 630kg to 2000kg Gen2 Regen
E&I PANEL Upgrade
GeN2 & Previous Gen2 Regen up to 1000kg
GeN2-Regen
Min E&I PANEL Apply to 630kg to 2000kg Gen2 Regen
Door Operator upgrade
GeN2
GeN2-Regen
&Previous Gen2 Regen up to 1000kg
Apply to 630kg to 2000kg Gen2 Regen STD: AT120
STD: NGSOK - NGSOK is OTIS global PM operator - DO2000 is still optional
Safety Gear Upgrade
GeN2
STD:9672D/E
GeN2-Regen
STD:HN6000B/C
Apply to 1150kg to 2000kg only
- HN6000B/C are OTIS global E3 safety components - Bigger running clearance. Ride quality is improved and false tripping is eliminated - 9672D/E are still optional
Layout Changes
New Controller & Drive Architecture Previous Gen2 Regen (OH-CONB604MRL controller)
GeN2-Regen (ACD2 MRL)
GeN2(OH-CON4424 Controller)
k g 0 0 2 0 ~ g k 6 3 0
New arrangement is easier for controller and drive inspection
E&I PANEL cutout size
GeN2
GeN2-Regen Apply to 630kg to 2000kg Gen2 Regen
Top floor Min E&I PANEL size reduced, the cutout 1600(H)x250(W).
New Bracket Spacing for top floor GeN2
Gen2-Regen
Apply to 630kg to 2000kg Gen2 Regen Top floor brackets -Stronger rail bracket made machine more stable - Noise and vibration is improved