FW CentrimasterGT3

January 27, 2018 | Author: fenix73418 | Category: Mechanical Fan, Mechanical Engineering, Technology, Nature
Share Embed Donate


Short Description

Download FW CentrimasterGT3...

Description

Centrimaster GT-3 Belt driven, single inlet centrifugal fans Technical Data

Version 12/2002

Centrimaster GT-3

CATALOGUE

Contents Contents ...................................................................3 Belt-driven, Single-inlet Centrifugal Fans ...............4 Versions..............................................................5 General Survey Charts .............................................6 Design Fan casing ..........................................................7 Fan inlet.............................................................7 Impellers ............................................................8 Shafts .................................................................8 Bearings .............................................................9 Materials and Finish, Motor ..................................10 Starting of Fans ......................................................11 Tolerances and Quality ..........................................12 Specification Text GTLF...............................................................13 GTLB ..............................................................14 GTHB..............................................................15 Fan Charts – Explanation......................................17 Acoustic Data – Explanation .................................18 Dimensions and Weights, Fan Charts, Acoustic Data GTLF-3-025 ...............................................20-21 GTLB-3-025...............................................22-23 GTLF-3-031 ..............................................24-25 GTLB-3-031...............................................26-27 GTLF-3-040 ...............................................28-29 GTLB/GTHB-3-040 ...................................30-31 GTLF-3-045 ..............................................32-33 GTLB/GTHB-3-045 ...................................34-35 GTLF-3-050 ..............................................36-37 GTLB/GTHB-3-050 ...................................38-39 GTLF-3-056 ..............................................40-41 GTLB/GTHB-3-056 ...................................42-43 GTLF-3-063 ..............................................44-45 GTLB/GTHB-3-063 ...................................46-47 GTLF-3-071 ..............................................48-49 GTLB/GTHB-3-071 ...................................50-51 GTLB/GTHB-3-080 ...................................52-53 GTLB/GTHB-3-090 ...................................54-55 GTLB/GTHB-3-100 ...................................56-57 GTLB-3-112...............................................58-61 GTLB-3-125...............................................62-65 GTLB-3-140...............................................66-69 Motor Data .......................................................70-76 Accessories Plummer block with grease nipple ...................77 Flexible connections, inlet................................78 Protective screen, inlet .....................................78 Flexible connections, outlet..............................79 Protective screen, outlet ...................................79 Counterflange, outlet .......................................79 Inspection cover ...............................................80 Drain ...............................................................80 Anti-vibration mountings .................................80 Flow measurement device.................................81 Painted finish...................................................82 Motor cover .....................................................82 Ordering codes..................................................83-84

Fläkt Woods Oy

FIFLO 4249 GB 02.12

3

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Belt-driven, Single-inlet Centrifugal Fans

The type GT CENTRIMASTER belt-driven, singleinlet centrifugal fans cover air flows up to 27 m3/s and pressure rises up to 3.300 Pa. The fan series consists of centrifugal fans available with two types of impeller: – Impeller with forward-curved blades for the GTLF fans – Impeller with backward-curved blades for the GTLB and GTHB fans The backward-curved blades in the GTLB fans have the same aerodynamic characteristics as those in the GTHB fans, but the GTHB is a reinforced version for higher speeds.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

4

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Versions Besides the normal version, the fans are also available in a spark-proof version. The smoke extraction version of GT has been tested by the French CTICM institute and by the Russian VNIIPO institute. CTICM has tested the fans for +400 °C, 2 hours and the tests cover GTLB-3-025–140 as well as GTLF-3031–071. VNIIPO has tested the fans for +400 °C, 2 hours and for +600 °C, 1 hour and the tests cover all single inlet GT-fans. As compared with the normal version, the fans in the smoke extraction version have metallic bearing dampers. The fans in the spark-proof version conform to the provisions of German Standard VDMA 24 169 3.1 – 3.2 and 3.4. The inlet cone is made of brass and in the GTLF fans the inlet is fitted with a brass band.

GTLB

The single-inlet fans are rated for continuous operation at temperatures up to +80 °C if the inlet of the fan is connected to the ducting. If the motor is exposed to the air stream, i.e. on afree inlet fan, the ambient temperature must not exceed +40 °C. Motors for higher temperatures are available to special order.

GTHB with painted finish

GTLF

Fläkt Woods Oy

FIFLO 4249 GB 02.12

5

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

General Survey Charts GTLF-3250

500

1000

2500

5000

10 000

25 000

50 000

Air flow, m3/h 3000

Sizes 025–071 2000

025

1000

040

031

045

050

Total pressure rise, Pa

056

063

071

500

200 100 0

0,1

0,2

0,5

1

2

3

4

5

10

15

Air flow, m3/s

GTLB/GTHB-3200 250

500

1000

2500

5000

10 000

25 000

50 000

Air flow, m3/h 4000

Sizes 025–140 090 080

045

040

2000

050 056

063 071 025

1000

031 100 112

Total pressure rise, Pa

500

125 140

200

100 0

0,1

0,2

0,5

1

2

3

4

5

10

15

30

Air flow, m3/s

Fläkt Woods Oy

FIFLO 4249 GB 02.12

6

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Design Fan Casing – Sizes 025–071

Fan Inlet

The fan casing is made of Sendzimir galvanised sheet steel. The casing side plates are stamped in one piece and the inlets are deep-pressed in the end walls. The fan casing is jointed by the "Pittsburg folding method" which produces tight, strong joints. This jointing method and the deep-pressed inlets guarantee a stable design and high, consistent quality. The fan tongue has been specially designed to offer optimised aerodynamic properties.

The design of the fan inlet is of vital importance to high fan efficiency and a low level of sound generated by the fan. On the size 025–071 GTLF fans, the inlet is directly deep-pressed into the end walls. On the GTLB and GTHB fans the inlet must be deeper and must also extend into the impeller with a certain amount of overlap and a small, accurately predetermined radial gap. The inlet cones of the GTLB and GTHB fans are deepdrawn in one piece and are fitted to end walls of GTLF fans. This means that the GTLB and GTHB fans have a "double inlet" that gives the fan casing additional rigidity. On the size 080–140 fans, the inlet cone is made separately for both types of fan and directly fitted to the end walls.

Fan Casing – Sizes 080–140 The fan casing is made of Sendzimir galvanised sheet steel. The casing of the size 080 and 090 fans is jointed by the Pittsburg folding method and the casing is as standard equipped with a stable, welded frame. The casing of the size 100–140 fan consists of five flanged sections that can be dismantled.

Pittsburg

Tunga för GTLB- och GTHB-fläktar

Fläkt Woods Oy

FIFLO 4249 GB 02.12

7

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Design Fan Impellers

Shafts

The fan impellers with backward-curved blades (GTLB and GTHB) are made of sheet steel and welded, coated with 60 mm thick epoxy powder, (colour: AM 8043, dark grey). The fan impellers with forward-curved blades (GTLF) are made of Sendzimir galvanised sheet steel. The impellers of the size 040–140 GTLB and GTHB fans are dynamically balanced to an accuracy to ISO 1940–1973 G 2.5 at the maximum speed. The impeller of the size 025–031 GTLB fans and all sizes of GTLF fans are dynamically balanced to accuracy according to ISO Standard 1940–1973 G 6.3 at the maximum speed. The impeller of the size 025–100 fans is secured to the shaft by means of a key.

The shafts are made of steel and are provided with keyways for the belt pulleys. The shafts are designed with a high factor of safety against fatigue, and for a critical speed, which is at least 20% higher than the maximum fan speed. The shafts have anti-corrosion protection.

Fan impeller of the type GTHB fans

Fan impeller of the type GTLF fans

Fläkt Woods Oy

FIFLO 4249 GB 02.12

8

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Design Bearings The size 025–071 GTLB and GTLF fans are equipped with single-row, deep-groove ball bearings (Y-bearings) that are permanently lubricated and sealed on both sides. These bearings are secured to the shaft by means of an eccentric locking collar. The bearings are supported by robust three-armed or four-armed bearing support. The size 080–100 GTLB fans are equipped with singlerow, deep-groove ball bearings seated in plummer blocks with grease nipple. These bearings are secured to the shaft by means of a tapered adapter sleeve. The bearings of the GTLB and GTLF fans are designed for a life cycle of 20.000 hours. The plummer blocks with grease nipple are supplied as accessories for the size 025–071 GTLF and GTLB fans. See under Accessories.

Bearing of the type GTLF and GTLB fans up to size 071.

The size 040–071 GTHB fans are equipped with singlerow, deep-groove ball bearings that are permanently lubricated and sealed on both sides. These bearings are secured to the shaft by means of a tapered adapter sleeve. This means that the dimension of the bearing increases by 5 mm in relation to the shaft and this increases the useful life of the bearing. The bearings are supported by a robust three-armed or four-armed bearing support. Plummer blocks with grease nipple are also available as accessories.

Bearing of the size 080 – 100 GTLB fans.

The size 080–100 GTHB fans and the size 112–140 GTLB fans are equipped with plummer blocks with roller bearings secured to a sturdy bearing bracket made of welded flat iron bar. All the roller bearings are as standard equipped with grease nipples. The bearings of the GTHB fans are designed for a life cycle of 40.000 hours.

GTHB-040-071

GTHB-080-100 and GTLB-112-140

Fläkt Woods Oy

FIFLO 4249 GB 02.12

9

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Materials and Finish, Motor Selecting the Motor

Materials and Finish

The shaft power (P, kW) and the recommended min. permissible motor output for direct on-line starting (PM, kW) are specified in the fan charts, i.e. the safety factor is already included. Base your motor selection on this PM figure.

The GX fans in the standard version meet the provisions of Environmental Class M2. Fan casing: Inlet cone: Shaft: Fan impeller:

Sendzimir galvanised sheet steel, (275 g/ m2 thick zinc) Sendzimir galvanised sheet steel in the normal version. Brass in the spark-proof version. Centreless-ground steel with anti-corrosion protection. GTLB and GTHB: Sheet steel, welded, coated with 60 mm epoxy powder and baked, colour: AM8043, dark grey. GTLF: Sendzimir galvanised steel.

The safety factor covers belt losses that arise with standardised belt pulleys. Recommendations: When selecting GTLB and GTHB fans (with backward-curved blades) that at a given speed have an output peak within their operating range, use this output peak for selecting a motor and not the output at the duty point. When selecting GTLF fans (with forward-curved blades) whose power demand, at a given speed, continuously increases as the air flow increases, use the shaft power demand P at the duty point (adding the safety factor!) or the recommended min. permissible motor output PM. If you cannot with certainty plot the duty point in the fan chart, select a motor for an output that is another 15–20 % higher.

Motor The GT fans are normally supplied with the motor mounted. This enables the fan to be trial run prior to dispatch and ABB can assume undivided warranty liability. If the fan is supplied without motor, the size and speed of the motor must be specified when the order is placed so that the correct belt drive can be selected. Detailed motor data is tabulated in separate tables. See under Motor Data. Belt Drive The belt drive consists of belt pulleys and belt(s). The pulleys have a separate Taper-Lock-type hub, which is easy to fit and remove. The belt guard and slide rails are included in the GT fan delivery.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

10

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Starting of Fans Power demand of the fan Transmission losses Motor output required to operate fan Select the motor Select starting procedure Direct on-line or star-delta starting Calculate the starting time Starting time is too long

Check the permissible motor starting time

Equipment for heavy starting

Select the starter

Starting time is too long

Check the tripping time of the overload protection

To calculate the starting time in direct on-line starting Use the following formula:

Symbols used

The calculated starting time is the time needed for accelerating the fan from rest to full speed. To calculate the starting time in star-delta starting Use the following formula:

FIFLO 4249 GB 02.12

= motor rating ............................................ kW

Pm 1)

= power demand with the fan running at rated speed (including any belt-drive losses) ...... kW

PY/D

= lowest rating of motor for which star-delta staringcan be employed ............... kW

Mst 3) ––––– M Mmax3) ––––– M nf J2)

= ratio of motor starting torque to normal torque

t

= starting time ................................................ s

= ratio of maximum motor torque to normal torque = rated speed of fan ................................. r/min = Moment of inertia of the system referred to the fan shaft ........................ kg m2

1) PM som redovisas i vissa katalogavsnitt. 2) The moment of inertia of the impeller is given in the fan charts. The moment of inertia of the motor can generally be disregarded. 3) See the catalogue of the motor supplier.

The calculated starting time is the time during which the stardelta starter must be in star for the fan to reach about 90 % of full speed, whereupon the starter switches over to delta. On star-delta starting, also check that the motor curve is higher than the fan torque curve during the star connection period. The lowest possible motor rating for star-delta starting can be calculated from the following expression.

Fläkt Woods Oy

P

11

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Tolerances and Quality ISO 9001 and ISO 14001 Quality

Tolerances The particulars in the charts of the size 040–140 GTLB- and GTHB fans are given with the tolerance specified in the DIN 24 166 Standard, Class 1. Tolerance Class 2 is applicable to the size 025–031 GTLB fans and all the GTLF fans.

Fläkt Woods has received quality management certification in accordance with ISO 9001. We document our quality management responsibility at every stage of our business activities from the product development to production, procurement and marketing. We have received environmental management certification in accordance with ISO 14001. We aim to minimise the impact of our business activities and our products on the environment.

Tolerance Class DIN 24166

1

2

3

Air flow qv:

±2,5%

±5,0%

±10,0%

Pressure rise, ∆pt:

±2,5%

±5,0%

±10,0%

Shaft power demand*, P:

+3,0%

+8,0%

+16,0%

Efficiency**, h:

–2,0%

–5,0%



A-weighted sound power level*, LWA: +3 dB

+4 dB

+6 dB

* Negative tolerance permissible ** Positive tolerance permissible

Fläkt Woods Oy

FIFLO 4249 GB 02.12

12

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Specification Text – GTLF

GXLF

GTLF

Fan details for the GTLF in accordance with DIN 24166, Class 2

Single-inlet centrifugal fan for a belt-drive. The fan casing is made of Sendzimir galvanised sheet steel, jointed by the "Pittsburg folding method". Fan impeller with forward-curved blades, made of Sendzimir galvanised sheet steel. The fan impeller is dynamically balanced to accuracy according to ISO Standard 1940 – 1973 G 6.3. The shaft is designed for a critical speed, which is at least 20% higher than the maximum fan speed. Single-row, deep-groove ball bearings are permanently lubricated and sealed on both sides. These bearings are secured to the shaft by means of an eccentric locking collar. The bearings are supported by three-arm or four-arm bearing supports. The specified aerodynamic performance has been measured in accordance with AMCA 210-85 and 300-85.

The quality management system of the supplier has been granted ISO 9001 certification and his environmental management system has been granted ISO 14001 certification. Air flow, qv .........................................................m3/s Total pressure rise, ∆pt ........................................Pa Power demand, P................................................kW Min. fan efficiency, η .........................................% Max. A-weighted total sound power level, LWA ...dB

– Normal version – Smoke extraction version – can withstand 400 °C for 2 hours – Spark-proof version

Fläkt Woods Oy

FIFLO 4249 GB 02.12

13

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Specification Text – GTLB

GTLB

Fan details for the GTLB in accordance with DIN 24166 Sizes 040–140: Class 1 Sizes 025–031: Class 2 The quality management system of the supplier has been granted ISO 9001 certification and his environmental management system has been granted ISO 14001 certification.

Single-inlet centrifugal fan for a belt-drive. The fan casing is made of Sendzimir galvanised sheet steel, jointed by the "Pittsburg folding method", in size 100 consisting of five sections with flanges. Fan impeller with backward-curved blades, made of sheet steel, welded and coated with 60 mm thick epoxy powder. The fan impeller is dynamically balanced to accuracy according to ISO Standard 1940 – 1973 G 2.5 (sizes 040–140) or G 6.3 (sizes 025–031). The shaft is designed for a critical speed, which is at least 20% higher than the maximum fan speed. Singlerow, deep-groove ball bearings are permanently lubricated and sealed on both sides. These bearings are secured to the shaft by means of an eccentric locking collar. The bearings are supported by three-arm or four-arm bearing supports. The size 080–100 fans are equipped with plummer blocks with ball bearings and the size 112–140 with plummer blocks with roller bearings fitted to a sturdy bearing bracket made of welded flat iron bar. The specified aerodynamic performance has been measured in accordance with AMCA 210-85 and 300-85.

Air flow, qv................................................................m3/s Total pressure rise, ∆pt ..............................................Pa Power demand, P ......................................................kW Min. fan efficiency, η ................................................% Max. A-weighted total sound power level, LWA .........dB

– Normal version – Smoke extraction version – can withstand 400 °C for 2 hours – Spark-proof version

Fläkt Woods Oy

FIFLO 4249 GB 02.12

14

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Specification Text – GTHB

GTHB

Fan details for the GTHB in accordance with DIN 24166, Class 1 The quality management system of the supplier has been granted ISO 9001 certification and his environmental management system has been granted ISO 14001 certification.

Single-inlet centrifugal fan for a belt-drive. The fan casing is made of Sendzimir galvanised sheet steel, jointed by the "Pittsburg folding method", in size 100 consisting of five sections with flanges. Fan impeller with backward-curved blades, made of sheet steel, welded, coated with 60 mm thick epoxy powder and baked. The fan impeller is dynamically balanced to accuracy according to ISO Standard 1940 – 1973 G 2.5. The shaft is designed for a critical speed, which is at least 20% higher than the maximum fan speed. The size 040–071 GTHB fans are equipped with singlerow, deep-groove ball bearings that are permanently lubricated and sealed on both sides. These bearings are secured to the shaft by means of a tapered adapter sleeve. The bearings are supported by a robust three-armed or four-armed bearing support. The size 080–100 GTHB fans are equipped with plummer blocks with roller bearings secured to a sturdy bearing bracket made of welded flat iron bar. The roller bearings are as standard equipped with grease nipples. The specified aerodynamic performance has been measured in accordance with AMCA 210-85 and 300-85.

Air flow, qv................................................................m3/s Total pressure rise, ∆pt ..............................................Pa Power demand, P ......................................................kW Min. fan efficiency, η ................................................% Max. A-weighted total sound power level, LWA .........dB

– Normal version – Spark-proof version

Fläkt Woods Oy

FIFLO 4249 GB 02.12

15

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Notes

Fläkt Woods Oy

FIFLO 4249 GB 02.12

16

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Explanation 10

The GT fan charts on the following pages are applicable to air with a density of 1.2 kg/m3. 1 = Air flow, m3/s (x-axis)

3000

3

= Air flow,

80 3000

1000

7 8

3000 .997

60

2500 .991

2000 .981

40

1500 500 80

L wA,dB 75 1000 r/min

200

85

90

95

= Total sound power level LwA (dB), broken line

6 0

1 qv 2000

= Power demand, P (kW)

0.1

3 m 3/s

2

4000

6000

8000

7

10000

1

m 3/h 2

1000

0.2

= Min. recommended motor rating for direct online starting, PM (kW)

1500 .959

100

1000 .903

100 50

J = 0.24 kgm 2

9

1500

P,kW

6

75 5

4

∆p t ,Pa

= Fan efficiency η, %

3500 1

2000

3

5

r/min η-korr

2500

= Total pressure rise, Pa (y-axis) = Fan speed, r/min

η,%

GTLBmax 2800

(x-axis)

4

GTHB-3-040 GTLB-3-040

81

0.5 1

1

2000

P M ,kW

2

80

GTHBmax 3500

2000

m3/h

15

3500

8 2

9

= Moment of inertia, J (kg = Fan size

11

= Dynamic pressure at the outlet, pd

12

= Connection loss at the inlet, ∆p1

2800 3000

3

= Connection loss at the outlet, ∆p2 + pd 14 = Protective screen at the inlet, ∆p3

15

= Protective screen at the outlet, ∆p4

11

pd

∆p 1

12

∆ p 2 + pd 13

4 6

3500 r/min

6 7

14

16

2500

4

10

13

2

m2)

∆p 3 ∆p 4

10

20 5

8 60

10 40

80 100

20

30

100 10

160 40

200

250

60

200

Pa

80

Pa

400 Pa

300

20

40

60

70 Pa

20

40

60

Pa

= Correction factor for the efficiency kη = Recommended operating range = Recommended operating range of a heavy-duty fan

The charts for fans with backward-curved blades include a kη scale that indicates how much the efficiency will decrease if the fan is running at low speed. This scale can be applied with high precision within the normal operating range at which the power consumption of the fan at a given speed is fairly independent of the air flow.

The bearing losses are included in the power consumption of the fan and influence its efficiency. The power consumed by the fan is defined in the fan chart as the power consumed at the shaft end and thus contains the bearing losses. The efficiency figures in the chart are applicable to a fan operating at max. speed.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

17

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Acoustic Data – Explanation Acoustic Data

Correction Kokt, dB

A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: LWokt(s) = LWA + Kokt(s) Where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

Speed range Sound path (s)

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz 1 000 2 000 4 000

LWA

LWA(s)

8 000

dB

dB

r/min

63

125

250

500

To outlet duct (1)

0 – 964 965 – 1928 1929 – 3200

0 -2 -3

5 -1 -4

2 3 -4

-3 -3 -1

-6 -6 -6

-9 -9 -8

-14 -14 -13

-18 -17 -16

0 0 0

8.2 6.4 4.1

To inlet duct (2)

0 – 964 965 – 1928 1929 – 3200

4 2 -2

3 -1 -5

0 0 -6

-3 -3 -2

-4 -5 -4

-9 -8 -7

-12 -10 -9

-14 -13 -14

0.4 0.3 0.8

7.8 6.2 3.3

To surroundings – the fan inlet and outlet ducted (3)

0 – 964 965 – 1928 1929 – 3200

-8 -10 -12

-5 -8 -14

-6 -6 -11

-8 -10 -8

-11 -12 -10

-15 -16 -16

-22 -25 -24

-33 -36 -35

-6.1 -7.3 -6.4

6.1 5.8 3.1

To fan outlet (open-discharge fan) (4)

0 – 964 965 – 1928 1929 – 3200

-9 -13 -17

0 -6 -9

0 1 -6

-3 -3 -1

-6 -6 -6

-9 -9 -8

-14 -14 -13

-18 -17 -16

-0.6 -0.5 -0.1

5.5 4.5 2.3

LWA(s) = LWA + [LWA(s) – LWA] where the correction figure LWA(s) – LWA can be obtained from the table. The table also includes correction figures LWt(s) – LWA(s) that can be used for obtaining the total sound power level on each sound path: LWt(s) = LWA(s) + [LWt(s) – LWA(s)] Description of sound path 1 = To outlet duct 2 = To inlet duct 3 = To inlet duct (the fan inlet and outlet ducted)

Test arrangement 2 1 3

4 = To fan outlet (for open-discharge fan)

2 4 3

Symbols used LWA s LWA(s) LWt(s) LWokt(s) Kokt(s) L ∆L LpA(s)

A-weighted sound power level emitted to outlet duct Sound path A-weighted sound power level equivalent to sound path s Total sound power level (without frequency weighting A), (corresponding to sound path s) Total sound power level at each octave band (without frequency weighting A), (corresponding to sound path s) Correction figure for breaking down sound level at each octave band, (corresponding to sound path s) Distance Distance absorption (applicable to ideal conditions with hemispherical sound propagation) A-weighted sound power level at distance L from fan, (corresponding to sound path s)

Fläkt Woods Oy

FIFLO 4249 GB 02.12

18

dB(A) dB(A) dB dB dB m dB dB(A)

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Acoustic Data – Explanation Distance absorption The following formula is used to obtain the sound pressure level LpA(s) on free sound emission to the surroundings (sound paths 3 and 4) at various distances L: LpA(s) = LWA(s) – ∆L where the distance absorption ∆L can be obtained from the table below: L, m

1

3

5

10

15

20

25

30

40

50

75

100

∆L, dB 8

17

22

28

31

34

36

37

40

42

45

48

Example: GTHB-3-045: Air flow qv = 2.2 m3/s, total pressure rise ∆pt = 1800 Pa. From fan chart:

Speed n = 2670 r/min. Power demand P = 5.25 kW. Fan efficiency η = 0.996 x 80% = 79.7%. A-weighted sound power level to outlet duct LWA = 95.7 dB(A).

If the fan has a ducted inlet and outlet, the sound level at each octave band and the total sound power level for each sound path will be the following: Inlet duct:

LW63Hz = 95.7 – 2 = 93.7 dB LWA = 95.7 + 0.8 = 96.5 dB(A) LWt = 96.5 + 3.3 = 99.8 dB

Sound path

63 Hz 125 Hz 250 Hz 500 Hz 1 kHz

2 kHz

4 kHz

8 kHz

LwA. dB(A)

Lwt. dB

Outlet duct

92.7

91.7

91.7

94.7

89.7

87.7

82.7

79.7

95.7

99.8

Inlet duct

93.7

90.7

89.7

93.7

91.7

88.7

86.7

81.7

96.5

99.8

Surroundings (the fan inlet and outlet ducted)

83.7

81.7

84.7

87.7

85.7

79.7

71.7

60.7

89.3

98.8

The A-weighted sound power level at a distance of one metre from the fan will be: LpA = 89.3–7 = 82.3 dB(A) If the fan has an open discharge, the A-weighted sound power level at the fan outlet will be: LwA = 95.7–0,1 = 95.6 dB(A). The corresponding sound power level at a distance of 50 metres will be: LpA = 95.6–42 = 53.6 dB(A).

Fläkt Woods Oy

FIFLO 4249 GB 02.12

19

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLF-3-025 Dimensions and Weights 381

Right-hand version with 90° direction of discharge shown

346

Fan shaft

45

239 6

174 ø9 22,5 Max. IEC112

20

213*)

248

388

486 ø 244 215

713*) 753

36*) 7

188

*) Distance between the anti-vibration mountings

30

Right-hand version (viewed from drive side) 322

30

473

322 456

493 322 299

261 167 33 43

771

30

230

90°

165

851

785



270°

Left-hand version (same dimensions as the right-hand version)

90°



Weight (kg) GTLF-3-025: 17,5 Belt drive: 3,0

270°

Outlet flange 239 ø10 15

19,5

15 19,5 15 4,5

322

179 209 219

Motor data: See separate motor list.

FIFLO 4249 GB 02.12

382

352

ø10

Fläkt Woods Oy

2 x 176

362

20

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLF-3-025 Belt-driven, single-inlet, forward-curved blades

2500

r/min 3000

58

50

GTLF-3-025

2000

η,%

Impeller diameter: 250 mm

50

2500

1000

1500

500

∆p t ,Pa

40

2000

95 90 1000

L wA,dB 85

200 100 50 0.2

0.6 qv

1000 0.1

1.4m 3/s

1

2000

3000

1000

J = 0.02 kgm 2 P M ,kW

0.2 P,kW

5000 m 3/h

4000

1500 2000 1

Acoustic Data

1

A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

2500 2

3000 2

r/min 4

3.5 pd

50

∆p 1

10

20

∆ p 2 + pd ∆p 3

Lwokt(s)=LWA+Kokt(s)

100

100

40

20

10

80

40

60

r/min

63

125

250

500

LWA(s)=LWA+[LwA(s)–LWA]

To outlet duct (1)

0 – 1116 1117 – 2233 2234 – 3000

4 5 5

5 4 2

1 -1 -3

-3 -6 -5

-7 -5 -7

-10 -8 -7

To inlet duct (2)

0 – 1116 1117 – 2233 2234 – 3000

8 7 6

-1 1 1

-4 -8 -5

-8 -11 -9

-6 -6 -9

To surroundings – the fan inlet and outlet ducted (3)

0 – 1116 1117 – 2233 2234– 3000

-8 -8 -8

-6 -7 -7

-5 -8 -10

-4 -10 -10

To fan outlet (open-discharge fan) (4)

0 – 1116 1117 – 2233 2234– 3000

-15 -16 -18

-3 -6 -10

-3 -5 -7

-5 -8 -6

Fläkt Woods Oy

80 80

Sound path (s)

Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)]

100

120 Pa

100

100

Correction, Kokt, dB Speed range

FIFLO 4249 GB 02.12

21

Pa

600

60

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path:

400 Pa

400 40

20

300

60

200

10

∆p 4

30

200

Pa

120 Pa

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz

LWA

LWA(s)

8 000

dB

dB

-10 -9 -8

-12 -11 -11

0 0 0

9 8.7 7.9

-12 -10 -8

-13 -10 -9

-19 -15 -12

-2.4 -2.0 -1.7

11.5 10.4 9.6

-7 -7 -8

-12 -9 -6

-17 -17 -13

-22 -23 -20

-2.6 -3.3 -2.1

4.1 3.2 2.2

-7 -5 -7

-10 -8 -7

-10 -9 -8

-12 -11 -11

-1.3 -0.6 -0.6

3.9 2.2 1.4

1 000 2 000 4 000

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLB-3-025 Dimensions and Weights 381

Right-hand version with 90° direction of discharge shown

346

Fan shaft

45

239 6

174 ø9 22,5 Max. IEC112

20

213*)

248

388

486 ø 244 215

713*) 753

36*) 7

188

*) Distance between the anti-vibration mountings

30

Right-hand version (viewed from drive side) 322

30

473

322 456

493 322 299

261 167 33 43

771

30

230

90°

165

851

785



270°

Left-hand version (same dimensions as the right-hand version)

90°



Weight (kg) GTLB-3-025: 18,5 Belt drive: 3,0

270°

Outlet flange 239 ø10 15

19,5

15 19,5 15 4,5

322

179 209 219

Motor data: See separate motor list.

FIFLO 4249 GB 02.12

382

352

ø10

Fläkt Woods Oy

2 x 176

362

22

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLB-3-025 Belt-driven, single-inlet, backward-curved blades

2200 2000

75

4500

75

4500 1

η,%

4000

Impeller diameter: 250 mm

r/min η-korr

GTLB-3-025

76

70

4000 .993

3500 3500 .982

60

1000 3000

3000 .966

2500 40

500

2500 .941

∆p t ,Pa

2000

Only the GTLB is available in the smoke extraction version.

L wA,dB 70 1500

200

75

80

85

90

95

2000 .898

r/min 1500 .817

100 50 0 500

0.2 qv

0.4 1000

0.6

1500

2000

1 m 3/s

0.8 2500

3500 m 3/h

3000

0.01 1500

J = 0.03 kgm 2 0.1

2000

0.1

0.2 2500

0.2

Acoustic Data

0.4

3000

A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

3500

0.6

0.8 1

4000 1

1.4

4500 r/min

1.8

1.6 pd

10

∆p 1

20 5

60 10

∆ p 2 + pd

Lwokt(s)=LWA+Kokt(s)

80 100 120

20

40

30

∆p 3

10

20

∆p 4

10

20

30

r/min

63

125

250

500

LWA(s)=LWA+[LwA(s)–LWA]

To outlet duct (1)

0 – 1928 1929 – 3857 3858 – 4500

1 -2 -4

2 0 -3

3 -7 -3

-4 0 -7

-7 -7 -3

-8 -10 -8

To inlet duct (2)

0 – 1928 1929 – 3857 3858 – 4500

1 -1 -4

2 0 -2

3 -8 -4

-4 -0 -7

-5 -5 -2

To surroundings – the fan inlet and outlet ducted(3)

0 – 1928 1929 – 3857 3858 – 4500

-7 -11 -13

-5 -10 -13

-4 -10 -9

-9 -8 -14

To fan outlet (open-discharge fan) (4)

0 – 1928 1929 – 3857 3858 – 4500

-16 -21 -25

-6 -9 -13

-1 -11 -7

-5 -1 -8

Fläkt Woods Oy

200 Pa

50

Pa 40

Pa

40

Pa

Correction, Kokt, dB Speed range

FIFLO 4249 GB 02.12

23

60 Pa

200

Sound path (s)

Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)]

160

40

100

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path:

P M ,kW

P,kW

0.05

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz

LWA

LWA(s)

8 000

dB

dB

-13 -12 -11

-16 -15 -15

0 0 0

7.5 5.1 3.7

-10 -11 -10

-13 -12 -12

-18 -17 -17

0 0.3 0.1

7.6 5.1 3.8

-12 -11 -10

-14 -18 -16

-21 -23 -22

-31 -34 -34

-6.1 -7.0 -7.5

6.7 4.3 3.5

-7 -7 -3

-8 -10 -8

-13 -12 -11

-16 -15 -15

-1.3 -0.8 0.3

3.9 2.3 1.0

1 000 2 000 4 000

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLF-3-031 Dimensions and Weights 419

Right-hand version with 90° direction of discharge shown

Fan shaft 50

393 277 8

212 ø9 28 Max. IEC132

25

253*)

286

495

591 ø 310 250

820*) 860

36*) 33

203

*) Distance between the anti-vibration mountings

30

Right-hand version (viewed from drive side) 404

30

548

404 528

613 404

379

292 187 38 92

935

33

249

90°

203

952

923



270°

Left-hand version (same dimensions as the right-hand version)

90°



Weight (kg) GTLF-3-031: 23,5 Belt drive: 4,0

270°

Outlet flange 277 ø10 15

19,5

15 19,5 15 4,5

404

217 247 257

Motor data: See separate motor list.

FIFLO 4249 GB 02.12

464

434

ø10

Fläkt Woods Oy

2 x 217

444

24

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLF-3-031 Belt-driven, single-inlet, forward-curved blades

2500

r/min 2400

50

60

η,%

62

60

2000 2200

Impeller diameter: 315 mm

2000

50

1800 1000

1600 40 1400 1200 95

1000 800

200

90 L wA,dB 85

600 100

GTLF-3-031

50 0.2

1 3000

1.4 4000

P,kW

0.2

1

Acoustic Data 2

2 m 3/s

1.8

5000

600 800 1000 1200 1400 1600 1800 2000 2200 2400 r/min

0.1

A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

0.6 qv 2000

7000 m 3/h

6000

0.2

J = 0.05 kgm 2

1

P M ,kW

∆p t ,Pa

500

2

4 4 7

6 pd

50

∆p 1

10

∆ p 2 + pd

50

20

200 40

40

20

80

Pa 100 Pa Pa

400

20

10

300

60

200

10

∆p 4

30

100

∆p 3

Lwokt(s)=LWA+Kokt(s)

100

60

40

60

80 80

Pa

100 Pa

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

Sound path (s)

r/min

63

125

250

500

8 000

dB

LWA(s)=LWA+[LwA(s)–LWA]

To outlet duct (1)

0 – 1010 1011 – 2020 2021 – 2400

3 5 5

4 4 4

-2 -2 -3

-2 -6 -7

-7 -5 -7

-9 -8 -6

-10 -9 -8

-11 -13 -12

0 0 0

8.0 8.6 8.5

To inlet duct (2)

0 – 1010 1011 – 2020 2021 – 2400

7 7 7

-3 -1 1

-6 -7 -6

-5 -9 -7

-4 -3 -8

-10 -8 -6

-12 -10 -8

-19 -15 -12

-0.8 -0.1 -0.5

9.0 8.5 9.2

To surroundings – the fan inlet and outlet ducted (3)

0 – 1010 1011 – 2020 2021 – 2400

-9 -8 -8

-6 -7 -9

-4 -6 -10

-3 -10 -12

-7 -7 -8

-11 -9 -5

-17 -17 -13

-21 -25 -21

-1.9 -3.3 -1.7

3.9 3.5 1.6

To fan outlet (open-discharge fan) (4)

0 – 1010 1011 – 2020 2021 – 2400

-13 -12 -13

-3 -4 -3

-5 -5 -6

-3 -7 -8

-7 -5 -7

-9 -8 -6

-10 -9 -8

-11 -13 -12

-0.7 -0.6 -0.5

3.4 2.7 2.6

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)]

Fläkt Woods Oy

Correction, Kokt, dB Speed range

FIFLO 4249 GB 02.12

25

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz 1 000 2 000 4 000

LWA

LWA(s)

dB

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLB-3-031 Dimensions and Weights 419

Right-hand version with 90° direction of discharge shown

Fan shaft 50

393 277 8

212 ø9 28 Max. IEC132

25

253*)

286

495

591 ø 310 250

820*) 860

36*) 33

203

*) Distance between the anti-vibration mountings

30

Right-hand version (viewed from drive side) 404

30

548

404 528

613 404

379

292 187 38 92

935

33

249

90°

203

952

923



270°

Left-hand version (same dimensions as the right-hand version)

90°



Weight (kg) GTLB-3-031: 25,0 Belt drive: 4,0

270°

Outlet flange 277 ø10 15

19,5

15 19,5 15 4,5

404

217 247 257

Motor data: See separate motor list.

FIFLO 4249 GB 02.12

464

434

ø10

Fläkt Woods Oy

2 x 217

444

26

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLB-3-031 Belt-driven, single-inlet, backward-curved blades

2200 2000

75

3600

77

3400 3200

Impeller diameter: 315 mm

r/min η-korr

GTLB-3-031

3600 1

η,%

3400 .997

75

3000

3200 .994

70

2800

3000 .99

2600

1000

2800 .985

60

2400

2600 .979

2200

2400 .972

2000

2200 .963

40

1800

500

2000 .951

∆p t ,Pa

1600

Only the GTLB is available in the smoke extraction version.

1800 .936

1400

1600 .915

1200 r/min L wA,dB 70

200

75

80

85

90

1200 .845

100 50 0

0.4 qv 1000

0.05

P,kW

0.1

Acoustic Data

0.2

0.6

A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

1 1.4 2 2.2

0.8 2000

10

∆p 1

4000

5

2 2.6 60 10

80 100 120

20

40

30

100

160

200

Pa

50

60

Pa

40

300 Pa

200

∆p 3

10

20

40

Pa

∆p 4

10

20

40

Pa

Sound path (s)

r/min

63

125

250

500

LWA(s)=LWA+[LwA(s)–LWA]

To outlet duct (1)

0 – 1928 1929 – 3600

1 -1

-1 -2

4 -6

-4 -2

-7 -6

-8 -7

To inlet duct (2)

0 – 1928 1929 – 3600

1 -2

-1 -5

3 -9

-1 0

-5 -4

To surroundings – the fan inlet and outlet ducted (3)

0 – 1928 1929 – 3600

-7 -10

-8 -12

-5 -9

-9 -9

To fan outlet (open-discharge fan) (4)

0 – 1928 1929 – 3600

-13 -18

-8 -9

1 -9

-5 -3

Fläkt Woods Oy

0.2

1

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)]

m 3/h 0.1

5000

J = 0.085 kgm2

20

∆ p 2 + pd

Lwokt(s)=LWA+Kokt(s)

3000

1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 r/min pd

1.6 m 3/s

1.2

P M ,kW

Note: Max. speed of the smoke extraction version is 3100 rpm.

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path:

1400 .886

95

Correction Kokt, dB Sound path (s)

FIFLO 4249 GB 02.12

27

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz

LWA

LWA(s)

8 000

dB

dB

-15 -12

-17 -16

0 0

7.3 4.5

-10 -8

-11 -10

-16 -16

0.9 1.0

6.4 3.4

-12 -10

-14 -15

-23 -23

-32 -35

-6.4 -6.4

6.0 3.8

-7 -6

-8 -7

-15 -12

-17 -16

-1.1 -0.6

4.5 1.8

1 000 2 000 4 000

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLF-3-040 Dimensions and Weights 516

Right-hand version with 90° direction of discharge shown

452

Fan shaft

50

329 8

263 ø9 33 Max. IEC132

30

303*)

338

543

744 ø 388 312

945*) 985

36*) 41

249

*) Distance between the anti-vibration mountings

30

Right-hand version (viewed from drive side) 507

30

600

507 764

653

507

469

363 239 38 121

1075

41

310

203

1130 90°

1041



270°

Left-hand version (same dimensions as the right-hand version)

90°



Weight (kg) GTLF-3-040: 39,0 Belt drive: 4,0

270°

Outlet flange 329 -

149,5 ø10 15

19,5

15 19,5 15 ø10 4,5

Motor data: See separate motor list.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

4x 134,3

546

567

537 507

269 299 308 28

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLF-3-040 Belt-driven, single-inlet, forward-curved blades

2000

r/min 1700

65 η,%

60

1600

60

Impeller diameter: 400 mm 1400 1000 1200

50

1000 40

500 100 600

200

95

90

L wA,dB 85 100

GTLF-3-040

50 0.5

1 qv 4000

2000

3 m 3/s

2 6000

8000

10000

m 3/h

0.1

0.2

0.2

600

P,kW

1000 1

1

1200

Acoustic Data 2

A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

J = 0.14 kgm 2

800

1400

2

1600 1700 r/min

3

5

4

7

6 pd

50

∆p 1

100

10

∆ p 2 + pd

20

50

40

20

10

40

20

40

60

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

Sound path (s)

r/min

63

125

250

500

LWA(s)=LWA+[LwA(s)–LWA]

To outlet duct (1)

0 – 1010 1011 – 1700

4 5

3 2

-2 -4

-3 -6

-6 -5

-8 -7

To inlet duct (2)

0 – 1010 1011 – 1700

5 6

2 -1

-7 -10

-6 -8

-3 -3

To surroundings – the fan inlet and outlet ducted (3)

0 – 1010 1011 – 1700

-8 -8

-6 -7

-4 -8

-4 -10

To fan outlet (open-discharge fan) (4)

0 – 1010 1011 – 1700

-11 -11

-3 -4

-4 -6

-4 -7

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] Fläkt Woods Oy

Pa

60

200

10

∆p 4

200

30

100

∆p 3

Lwokt(s)=LWA+Kokt(s)

80

Speed range

29

Pa

400

Pa

60

Pa 80

Correction, Kokt, dB

FIFLO 4249 GB 02.12

P M ,kW

∆p t ,Pa

800

Pa

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz

LWA

LWA(s)

8 000

dB

dB

-10 -9

-14 -13

0 0

7.9 7.8

-7 -6

-10 -10

-16 -14

0.4 0.4

7.4 7.3

-6 -7

-10 -8

-17 -17

-24 -25

-1.8 -3.0

3.8 3.0

-6 -5

-8 -7

-10 -9

-14 -13

-0.6 -0.4

3.4 2.5

1 000 2 000 4 000

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLB/GTHB-3-040 Dimensions and Weights 516

Right-hand version with 90° direction of discharge shown

452

Fan shaft

50

329 8

263 ø9 33 Max. IEC132

30

303*)

338

543

744 ø 388 312

945*) 985

36*) 41

*) Distance between the anti-vibration mountings

249 30

Right-hand version (viewed from drive side) 507

30

600

507 764

653

507

469

363 239 38 121

1075

41

310

203

1130 90°

1041



270°

Left-hand version (same dimensions as the right-hand version)

90°



Weight (kg) GTLB/HB-3-040: 41,0 Belt drive: 4,0

270°

Outlet flange 329 -

149,5 ø10 15

19,5

15 19,5 15 ø10 4,5

Motor data: See separate motor list.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

4x 134,3

546

567

537 507

269 299 308 30

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLB/GTHB-3-040 Belt-driven, single-inlet, backward-curved blades

3500 80

GTHBmax 3500

3000

Impeller diameter: 400 mm

r/min η-korr

GTHB-3-040 80 GTLB-3-040

81

3500 1

η,%

3000

75 3000 .997

GTLBmax 2800

2000

2500 60

2500 .991

2000

1000

2000 .981

40

Only the GTLB is available in the smoke extraction version.

80

L wA,dB 75 1000 r/min

200

85

90

95

1500 .959

100

1000 .903

100 50 0

1 qv 2000

0.1

3 m 3/s

2

4000

6000

8000

10000

m 3/h

1000

0.2

J = 0.24 kgm 2 0.5

P,kW

1500

1

1

2000

Acoustic Data

2 2

A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

2500 2800 3000

3 4

4 6

3500 r/min

6 7 pd

10

∆p 1

20 5

∆ p 2 + pd

8 60

10

80 100

20

40

∆p 3

Lwokt(s)=LWA+Kokt(s)

30

100 10

∆p 4

160 40

60

80

60

70 Pa

20

40

60

Pa

63

125

250

500

LWA(s)=LWA+[LwA(s)–LWA]

To outlet duct (1)

0 – 1928 1929 – 3500

1 -1

-2 -3

2 -7

-5 -2

-5 -5

-8 -7

To inlet duct (2)

0 – 1928 1929 – 3500

2 -1

0 -4

-2 -10

-3 -2

-6 -4

To surroundings – the fan inlet and outlet ducted (3)

0 – 1928 1929 – 3500

-7 -10

-9 -13

-6 -10

-10 -9

To fan outlet (open-discharge fan) (4)

0 – 1928 1929 – 3500

-11 -16

-7 -8

0 -9

-6 -3

FIFLO 4249 GB 02.12

31

Pa

400 Pa

300

Correction, Kokt, dB Speed range

Pa

40

r/min

Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)]

250

20

Sound path (s)

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path:

200

200

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

Fläkt Woods Oy

P M ,kW

∆p t ,Pa

1500 500

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz

LWA

LWA(s)

8 000

dB

dB

-15 -12

-18 -17

0 0

6.3 4.4

-9 -6

-11 -8

-11 -15

-0.3 1.1

6.6 3.3

-10 -9

-14 -15

-23 -23

-33 -36

-6.2 -6.0

5.3 3.3

-5 -5

-8 -7

-15 -12

-18 -17

-0.8 -0.3

3.9 1.8

1 000 2 000 4 000

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLF-3-045 Dimensions and Weights 545

Right-hand version with 90° direction of discharge shown

Fan shaft 55

488 359 10

293 ø9 38 Max. IEC160

35

338*) 378

621

824 ø 445 338

1080*) 1120

36*) 41

282

*) Distance between the anti-vibration mountings

30

Right-hand version (viewed from drive side) 569

30

685

569 858

718

569

525

396 257 41 133

1205

38

354

282

1252 90°

1161



270°

Left-hand version (same dimensions as the right-hand version)

90°



Weight (kg) GTLF-3-045: 45,0 Belt drive: 5,0

270°

Outlet flange 359 -

164,5 ø10 15

19,5

15 19,5 15 ø10 4,5

Motor data: See separate motor list.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

4x 149,8

608

629

599 569

299 329 338 32

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLF-3-045 Belt-driven, single-inlet, forward-curved blades

2000

r/min 1500

60

65

η,%

1400

Impeller diameter: 450 mm

60

1300 1200 1000

50

1100 1000 900

40

800

500

100

600 95

200 L wA,dB 85

90

100

GTLF-3-045

50 0.5

1

2

qv 4000

6000

4 m 3/s

3 8000

10000

14000 m /h

12000

P,kW

0.2

1

2

Acoustic Data A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

0.4

600 700 800 900 1000 1100 1200 1300 1400 1500 r/min

J = 0.23 kgm 2 1 2

5

5 8 10

8 pd

50

∆p 1

10

∆ p 2 + pd ∆p 3

Lwokt(s)=LWA+Kokt(s)

100 20

50

30

100 10

∆p 4

10

200 40

200 40 40

60

r/min

63

125

250

500

LWA(s)=LWA+[LwA(s)–LWA]

To outlet duct (1)

0 – 1010 1011 – 1500

1 1

3 2

-2 -4

-3 -5

-6 -5

-7 -7

To inlet duct (2)

0 – 1010 1011 – 1500

3 3

1 -2

-5 -8

-5 -6

-2 -2

To surroundings – the fan inlet and outlet ducted (3)

0 – 1010 1011 – 1500

-11 -12

-6 -9

-5 -8

-4 -9

To fan outlet (open-discharge fan) (4)

0 – 1010 1011 – 1500

-14 -15

-2 -3

-4 -6

-3 -5

Fläkt Woods Oy

100

80 80

100

Correction, Kokt, dB Speed range

FIFLO 4249 GB 02.12

33

Pa

600 Pa

60

Sound path (s)

Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)]

80

Pa

400

20 20

300

60

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path:

P M ,kW

∆p t ,Pa

700

Pa Pa

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz

LWA

LWA(s)

8 000

dB

dB

-11 -10

-15 -14

0 0

6.9 6.2

-7 -6

-10 -9

-15 -13

1.0 1.2

7.9 7.3

-6 -7

-9 -8

-18 -18

-25 -26

-1.7 -2.9

3.3 2.2

-6 -5

-7 -7

-11 -10

-15 -14

-0.2 -0.3

3.5 2.7

1 000 2 000 4 000

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLB/GTHB-3-045 Dimensions and Weights 545

Right-hand version with 90° direction of discharge shown

Fan shaft 55

488 359 10

293 ø9 38 Max. IEC160

35

338*) 378

621

824 ø 445 338

1080*) 1120

36*) 41

*) Distance between the anti-vibration mountings

282 30

Right-hand version (viewed from drive side) 569

30

685

569 858

718

569

525

396 257 41 133

1205

38

354

282

1252 90°

1161



270°

Left-hand version (same dimensions as the right-hand version)

90°



Weight (kg) GTLG/HB-3-045: 49,5 Belt drive: 5,0

270°

Outlet flange 359 -

164,5 ø10 15

19,5

15 19,5 15 ø10 4,5

Motor data: See separate motor list.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

4x 149,8

608

629

599 569

299 329 338 34

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLB/GTHB-3-045 Belt-driven, single-inlet, backward-curved blades

3500

80

GTHBmax 3200 3000

3000

81 80

r/min η-korr

GTHB-3-045 GTLB-3-045

3200 1

η,%

Impeller diameter: 450 mm

3000 .999

75 GTLBmax 2500

2000

2500 .995

60 2000 1000

2000 .987

∆p t ,Pa

1500

Only the GTLB is available in the smoke extraction version.

40

500

1500 .972

1000 r/min

200

L wA,dB 80

85

95

90

100 1000 .93

100 50 0

1 qv

2000 0.2

2

4000

6000

8000

10000

0.5 1

1500 1

1.5 2

2000

P M ,kW

P,kW

J = 0.46 kgm 2

2

3 3

A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

4

2500

4

6 6

3000

8

3200 r/min

8

10

10 pd

10

∆p 1

20 5

40 10

∆ p 2 + pd

Lwokt(s)=LWA+Kokt(s)

40

60 80 100 20

30

100

150 40

60

200

100

500 Pa

400

10

20

40

60

80

Pa

∆p 4

10

20

40

60

80

Pa

63

125

250

500

LWA(s)=LWA+[LwA(s)–LWA]

To outlet duct (1)

0 – 964 965 – 1928 1929 – 3200

0 -2 -3

5 -1 -4

2 3 -4

-3 -3 -1

-6 -6 -6

-9 -9 -8

To inlet duct (2)

0 – 964 965 – 1928 1929 – 3200

4 2 -2

3 -1 -5

0 0 -6

-3 -3 -2

-4 -5 -4

To surroundings – the fan inlet and outlet ducted (3)

0 – 964 965 – 1928 1929 – 3200

-8 -10 -12

-5 -8 -14

-6 -6 -11

-8 -10 -8

To fan outlet (open-discharge fan) (4)

0 – 964 965 – 1928 1929 – 3200

-9 -13 -17

0 -6 -9

0 1 -6

-3 -3 -1

Correction, Kokt, dB Speed range

FIFLO 4249 GB 02.12

Pa

∆p 3

r/min

Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)]

80

300

Sound path (s)

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path:

12 250 300 350 Pa

200

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

Fläkt Woods Oy

14000 m 3/h

12000

1000

0.5

Acoustic Data

4 m 3/s

3

35

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz

LWA

LWA(s)

8 000

dB

dB

-14 -14 -13

-18 -17 -16

0 0 0

8.2 6.4 4.1

-9 -8 -7

-12 -10 -9

-14 -13 -14

0.4 0.3 0.8

7.8 6.2 3.3

-11 -12 -10

-15 -16 -16

-22 -25 -24

-33 -36 -35

-6.1 -7.3 -6.4

6.1 5.8 3.1

-6 -6 -6

-9 -9 -8

-14 -14 -13

-18 -17 -16

-0.6 -0.5 -0.1

5.5 4.5 2.3

1 000 2 000 4 000

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLF-3-050 Dimensions and Weights 581

Right-hand version with 90° direction of discharge shown

533

Fan shaft

65

394 10

328 ø 12 38 Max. IEC160

35

383*)

433

657

912 ø 495 372

1200*) 1250

36*) 48

304

*) Distance between the anti-vibration mountings

30

Right-hand version (viewed from drive side) 638

30

722

638 950

801

638

580

449 276 40 109

1331

48

432

304

1388 90°

1298



270°

Left-hand version (same dimensions as the right-hand version)

90°



Weight (kg) GTLF-3-050: 56,0 Belt drive: 5,0

270°

Outlet flange 394 -

182 ø10 15

19,5

15 19,5 15 ø10 4,5

Motor data: See separate motor list.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

4 x 167

677

698

668 638

334 364 373 36

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLF-3-050 Belt-driven, single-inlet, forward-curved blades

2000 r/min 1300

Impeller diameter: 500 mm

η,%

65

60

60

1200 50

1100 1000

1000 40

900 800 700 105

600 100

500

200

L wA,dB 85

400

90

95

100

GTLF-3-050

50 0.5

1

2

qv 4000 6000

P,kW

0.2

A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

8000

1

10000

12000

14000

1 2

5

10

pd

50

∆p 1

100

10

∆ p 2 + pd ∆p 3

50

20

30

100

200 40

200

10

40

20

80

100

40

60 60

Sound path (s)

r/min

63

125

250

500

LWA(s)=LWA+[LwA(s)–LWA]

To outlet duct (1)

0 – 1010 1011 – 1300

-2 -2

2 1

-2 -5

-3 -4

-6 -5

-7 -7

To inlet duct (2)

0 – 1010 1011 – 1300

1 0

-2 -3

-3 -8

-4 -3

-2 -2

To surroundings – the fan inlet and outlet ducted (3)

0 – 1010 1011 – 1300

-14 -15

-7 -8

-5 -9

-4 -8

To fan outlet (open-discharge fan) (4)

0 – 1010 1011 – 1300

-14 -14

-2 -3

-4 -7

-3 -4

80 80

FIFLO 4249 GB 02.12

37

Pa

100

Correction, Kokt, dB Speed range

Pa

600 Pa

400

20

10

14 Pa

300

60

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

Fläkt Woods Oy

0.4

J = 0.32 kgm 2

10 11

∆p 4

Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)]

18000 m 3/h

16000

5

Lwokt(s)=LWA+Kokt(s)

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path:

5 m 3/s

4

400 500 600 700 800 900 1000 1100 1200 1300 r/min

2

Acoustic Data

3

P M ,kW

∆p t ,Pa

500

Pa

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz

LWA

LWA(s)

8 000

dB

dB

-11 -10

-15 -14

0 0

5.9 5.1

-7 -6

-9 -8

-15 -13

1.3 1.7

7.1 6.8

-6 -7

-9 -8

-18 -18

-25 -26

-1.7 -2.8

3.0 2.1

-6 -5

-7 -7

-11 -10

-15 -14

-0.2 -0.2

3.5 2.7

1 000 2 000 4 000

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLB/GTHB-3-050 Dimensions and Weights 581

Right-hand version with 90° direction of discharge shown Fan shaft 65

533 394 10

328 ø 12 38 Max. IEC160

35

383*)

433

657

912 ø 495 372

1200*) 1250

36*) 48

304

*) Distance between the anti-vibration mountings

30

Right-hand version (viewed from drive side) 638

30

722

638 801

950 638

580

449 276 40 109

1331

48

432

304

1388 90°

1298



270°

Left-hand version (same dimensions as the right-hand version)

90°

Weight (kg) GTLB/HB-3-050: Belt drive:



270°

Outlet flange 61,0 5,0

394 -

182 ø10 15

19,5

15 19,5 15 ø10 4,5

Motor data: See separate motor list.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

4 x 167

677

698

668 638

334 364 373 38

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLB/GTHB-3-050 3500 80

GTHBmax 2800 2600

80

Impeller diameter: 500 mm

r/min η-korr

GTHB-3-050 GTLB-3-050

82

3000 2400

2800 1

η,%

2600 .999

75

2400 .998

2200 GTLBmax 2100 2000

2000

2200 .996

60

1800

2000 .994 1800 .992

1600

1000

1600 .988

1400 40

∆p t ,Pa

1200

Only the GTLB is available in the smoke extraction version.

1200 .975

1000

L wA,dB 80

85

90

95

100 1000 .961

800 r/min

200

800 .938

100 50

Note: Max. speed of the smoke extraction version is 870 rpm.

0

1 qv 4000

2000 0.1 0.2

2 6000

3 8000

5 m 3/s

4

m 3/h

10000 12000 14000 16000

800 0.5

J = 0.70 kgm 2

1000 P,kW

1400 .983

500

1200 1

1

1400 1600

2

3

2000 2100 2200

4

A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

2

1800

Acoustic Data

4 6

2400 2600 8

8

2800 r/min 10

∆p 1

20 5

60 80 100 10

∆ p 2 + pd

40

∆p 3

Lwokt(s)=LWA+Kokt(s)

20

30

100 10

∆p 4

160 200 40

60

200

500Pa

400 60

80

Pa

20

40

60

80

Pa

63

125

250

500

LWA(s)=LWA+[LwA(s)–LWA]

To outlet duct (1)

0 – 964 965 – 1928 1929 – 2800

-4 -4 -5

5 0 -4

2 3 -2

-5 -5 0

-5 -5 -6

-9 -9 -10

To inlet duct (2)

0 – 964 965 – 1928 1929 – 2800

4 1 -4

2 -2 -6

-1 1 -3

-3 -4 -1

-3 -4 -4

To surroundings – the fan inlet and outlet ducted (3)

0 – 964 965 – 1928 1929 – 2800

-12 -12 -14

-6 -7 -14

-7 -5 -9

-10 -12 -7

To fan outlet (open-discharge fan) (4)

0 – 964 965 – 1928 1929 – 2800

-12 -13 -17

1 -4 -8

1 2 -3

-5 -5 0

Correction, Kokt, dB Speed range

FIFLO 4249 GB 02.12

39

Pa

40

r/min

Fläkt Woods Oy

100

20

Sound path (s)

Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)]

80

300

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path:

10 12 14 250 300 350 Pa

12 pd

P M ,kW

Belt-driven, single-inlet, backward-curved blades

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz

LWA

LWA(s)

8 000

dB

dB

-14 -14 -14

-19 -17 -17

0 0 0

7.7 6.2 4.4

-10 -8 -8

-13 -11 -10

-17 -16 -14

0.4 0.4 0.9

7.4 5.8 3.3

-10 -11 -10

-15 -16 -18

-22 -25 -25

-34 -36 -36

-6.4 -7.2 -6.2

5.2 6.0 3.4

-5 -5 -6

-9 -9 -10

-14 -14 -14

-19 -17 -17

-0.5 -0.4 0

5.8 5.0 3.2

1 000 2 000 4 000

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLF-3-056 Dimensions and Weights 632

Right-hand version with 90° direction of discharge shown Fan shaft 65

585 435 12

368 ø 12 43 Max. IEC180

40

424*)

474

686

1030 ø 562 422

1314*) 1364

36*) 55

335

*) Distance between the anti-vibration mountings

30

Right-hand version (viewed from drive side) 715

30

790

715 1060

902

715

644

512 315 34 141

1493

37

467

90°

335

1561

1435



270°

Left-hand version (same dimensions as the right-hand version)

90°



Weight (kg) GTLF-3-056: 84,0 Belt drive: 6,0

270°

Outlet flange 109,3 ø10 15

435 186,3

19,5

15 19,5 15 ø10 4,5

Motor data: See separate motor list.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

4x 186,3

754

775

745 715

375 405 414 40

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLF-3-056 Belt-driven, single-inlet, forward-curved blades

2200 2000

r/min 1300

65

60

η,%

1200

Impeller diameter: 560 mm

60

1100 50

1000 1000

900 40 800 700

30

500

∆p t ,Pa

600 500 200

L wA,dB 80

85

90

95

100

100

GTLF-3-056

50 1

2 5000

3 qv

4

10000

5

15000

6.5 m 3/s

6

m 3/h

20000

0.5 500 600 700 800 900 1000 1100 1200 1300 r/min

2

Acoustic Data A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

16

14 pd

40

∆p 1

60

10

80 100 120

20

∆ p 2 + pd

Sound path (s)

LWA(s)=LWA+[LwA(s)–LWA]

To outlet duct (1)

30

100

∆p 3

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

Fläkt Woods Oy

4

10

10

160

200

40 300

40

80

350 Pa 100

60 60

80 80

LWA

LWA(s)

8 000

dB

dB

-11 -10

-16 -14

0 0

5.7 5.2

-6 -7

-10 -10

-15 -14

1.2 1.5

4.6 3.7

-6 -7

-9 -8

-18 -18

-26 -26

-1.7 -2.8

3.0 2.0

-6 -5

-7 -7

-11 -10

-16 -14

-0.2 -0.1

3.7 2.9

125

250

500

0 – 884 885 – 1200

-2 -2

1 1

-1 -4

-3 -4

-6 -5

-7 -7

To outlet duct (2)

0 – 884 885 – 1200

2 1

-3 -4

-4 -7

-5 -5

-2 -1

To surroundings – the fan inlet and outlet ducted (3)

0 – 884 885 – 1200

-14 -15

-7 -10

-5 -8

-4 -8

To fan outlet (open-discharge fan) (4)

0 – 884 885 – 1200

-13 -14

-3 -3

-2 -5

-3 -4

41

Pa

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz 63

FIFLO 4249 GB 02.12

r/min

Pa

100

Correction, Kokt, dB Speed range

Pa Pa

400

40

20

300

60

160 200 20

∆p 4

Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)]

2

10

Lwokt(s)=LWA+Kokt(s)

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path:

1 J = 0.60 kgm 2 P M ,kW

P,kW

1

1 000 2 000 4 000

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLB/GTHB-3-056 Dimensions and Weights 632

Right-hand version with 90° direction of discharge shown

585

Fan shaft

65

435 12

368 ø 12 43 Max. IEC180

40

424*)

474

686

1030 ø 562 422

1314*) 1364

36*) 55

335

*) Distance between the anti-vibration mountings

30

Right-hand version (viewed from drive side) 715

30

790

715 1060

902

715

644

512 315 34 141

1493

37

467

90°

335

1561

1435



270°

Left-hand version (same dimensions as the right-hand version)

90°

Weight (kg) GTLB/HB-3-056: Belt drive:



270°

Outlet flange 91,0 8,0

109,3 ø10 15

435 186,3

19,5

15 19,5 15 ø10 4,5

Motor data: See separate motor list.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

4x 186,3

754

775

745 715

375 405 414 42

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLB/GTHB-3-056 Belt-driven, single-inlet, backward-curved blades

3500

GTHBmax 2500 2400

3000

80

82

η,%

80

r/min η-korr

GTHB-3-056 GTLB-3-056

2500 1 2400 1

2200

Impeller diameter: 560 mm

75 GTLBmax 2000

2000

2200 .998

1800

2000 .997

60

1600

1800 .995

1400

1000

1600 .993

Only the GTLB is available in the smoke extraction version.

500

40

1000 r/min

1400 .989

100 L wA,dB 80

90

85

95

1200 .983

200

1000 .973

100 50 0.5

1

2000

2 qv 6000

4000

3

4

6 m 3/s

5

8000 10000 12000 14000 16000 18000 20000

m 3/h

0.5

1

1000

P,kW

1

1200

A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

6

3

1600

3 4

2

1400

2

Acoustic Data

J = 1.10 kgm 2

4 5 6

1800 2000

8

2200

10

2400 2500 r/min

10

20

∆p 1

60

5

∆ p 2 + pd

Lwokt(s)=LWA+Kokt(s)

10

100

20

40

140

30

200

40

100

200

400 Pa

∆p 3

10

20

40

60

Pa

∆p 4

10

20

40

60

Pa

r/min

63

125

250

500

LWA(s)=LWA+[LwA(s)–LWA]

To outlet duct (1)

0 – 964 965 – 1928 1929 – 2500

-5 -5 -6

4 -2 -5

1 2 -3

-5 -5 -1

-4 -4 -5

-9 -9 -9

To inlet duct (2)

0 – 964 965 – 1928 1929 – 2500

0 -2 -5

3 -3 -6

0 1 -5

-5 -6 -1

-3 -3 -4

To surroundings – the fan inlet and outlet ducted (3)

0 – 964 965 – 1928 1929 – 2500

-13 -13 -14

-5 -9 -12

-7 -5 -10

-10 -12 -8

To fan outlet (open-discharge fan) (4)

0 – 964 965 – 1928 1929 – 2500

-13 -14 -16

0 -6 -9

0 1 -4

-5 -5 -1

Fläkt Woods Oy

80 90 Pa

300

Sound path (s)

Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)]

250

60

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path:

12 14 16 300Pa

14 pd

Correction, Kokt, dB Speed range

FIFLO 4249 GB 02.12

43

P M ,kW

∆p t ,Pa

1200

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz

LWA

LWA(s)

8 000

dB

dB

-14 -14 -14

-18 -17 -17

0 0 0

7.0 5.4 3.7

-8 -8 -8

-12 -12 -11

-15 -15 -14

0.6 0.4 0.7

6.4 4.9 3.0

-9 -10 -11

-15 -16 -16

-22 -25 -25

-33 -36 -36

-5.9 -6.8 -6.8

5.1 5.1 3.5

-4 -4 -5

-9 -9 -9

-14 -14 -14

-18 -17 -17

-0.3 -0.2 0

5.0 4.1 2.7

1 000 2 000 4 000

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLF-3-063 Dimensions and Weights 674

Right-hand version with 90° direction of discharge shown

628

Fan shaft

65

477 14

409 ø 12 48,5 Max. IEC180

45

466*)

516

706

1149 ø 620 468

1395*) 1445

36*) 59

375

*) Distance between the anti-vibration mountings

50

Right-hand version (viewed from drive side) 801

30

845

801 1188

1000

801

722

566 350 41 199

1504

59

482

90°

375

1716

1539



270°

Left-hand version (same dimensions as the right-hand version)

90°



Weight (kg) GTLF-3-063: 107,0 Belt drive: 6,0

270°

Outlet flange 119,6 ø10 15

477 207,8

19,5

15 19,5 15 ø10 4,5

Motor data: See separate motor list.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

4x 207,8

840

861

831 801

417 447 456 44

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLF-3-063 Belt-driven, single-inlet, forward-curved blades

1800

r/min 1000

Impeller diameter: 630 mm

69

65

60

η,% 65 60

900 1000

800 700

500

90

500 85

400 200 L wA,dB 80

300 100

GTLF-3-063

50 1

P,kW

5000

5 15000

1 2

8 m 3/s

7 20000

m 3/h

25000

300 400 500 600 700

J = 0.90 kgm 2 2

800

Acoustic Data

4

900 1000 r/min

A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

10 10 18

16 pd

40

∆p 1

10

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

Sound path (s)

LWA(s)=LWA+[LwA(s)–LWA]

To outlet duct (1)

Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)]

100 30

100

∆p 3 10

160

200

50

60

40 200

300

20

∆p 4

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path:

60 20

∆ p 2 + pd 40

Lwokt(s)=LWA+Kokt(s)

Fläkt Woods Oy

3 qv 10000

P M ,kW

∆p t ,Pa

40

95

600

40

80

350 Pa 100

60 60

80 80

LWA

LWA(s)

8 000

dB

dB

-11 -10

-16 -15

0 0

5.7 5.7

-6 -6

-10 -9

-16 -15

1.2 1.2

4.5 4.4

-6 -7

-9 -8

-18 -18

-26 -27

-1.8 -3

2.9 2.2

-6 -5

-7 -7

-11 -10

-16 -15

-0.1 -0.3

3.9 3.7

125

250

500

0 – 785 786 – 1000

-2 -1

1 2

-1 -4

-3 -5

-6 -5

-7 -7

To inlet duct (2)

0 – 785 786 – 1000

2 2

-4 -5

-4 -4

-5 -6

-2 -2

To surroundings – the fan inlet and outlet ducted (3)

0 – 785 786 – 1000

-14 -14

-7 -8

-6 -9

-4 -9

To fan outlet (open-discharge fan) (4)

0 – 785 786 – 1000

-10 -9

-2 -1

-2 -5

-3 -5

45

Pa

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz 63

FIFLO 4249 GB 02.12

r/min

Pa

100

Correction, Kokt, dB Speed range

Pa

600 Pa

400

40

20

300

1 000 2 000 4 000

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLB/GTHB-3-063 Dimensions and Weights 674

Right-hand version with 90° direction of discharge shown

628

Fan shaft

65

477 14

409 ø 12 48,5 Max. IEC180

45

466*)

516

706

1149 ø 620 468

1395*) 1445

36*) 59

375

*) Distance between the anti-vibration mountings

50

Right-hand version (viewed from drive side) 801

30

845

801 1188

1000

801

722

566 350 41 199

1504

59

482

90°

375

1716

1539



270°

Left-hand version (same dimensions as the right-hand version)

90°



Weight (kg) GTLB/HB-3-063: 115,0 Belt drive: 8,0

270°

Outlet flange 119,6 ø10 15

477 207,8

19,5

15 19,5 15 ø10 4,5

Motor data: See separate motor list.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

4x 207,8

840

861

831 801

417 447 456 46

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLB/GTHB-3-063 Belt-driven, single-inlet, backward-curved blades

3500 80

r/min η-korr

GTHB-3-063 η,% GTLB-3-063

84

GTHBmax 2100 2000

3000

2100 1 2000 1

80

Impeller diameter: 630 mm

1800

75

2000

1800 .999

GTLBmax 1600

1600 .997

60

1400

1400 .995

1000

1200 1200 .992

40

Only the GTLB is available in the smoke extraction version.

1000 .986

500

800 L wA,dB 80

600 r/min

200

85

90

95

600 .956

100 50 0

1

2

3

qv 5000 0.2

4

10000

5

15000

6

P,kW

Acoustic Data

0.5 J = 2.0 kgm 2

1000 2

2

1200

3 4

1400

6 8

1800 10

10

2000 2100 r/min

14 16 pd

10

∆p 1

20 5

60 80 100 10

∆ p 2 + pd

40

∆p 3

15

20

30

100 10

∆p 4

160 200 40

250 300 350 Pa

60

200

80

300

100

Pa

400

40

60

80

Pa

20

40

60

80

Pa

Sound path (s)

r/min

63

125

250

500

LWA(s)=LWA+[LwA(s)–LWA]

To outlet duct (1)

0 – 815 816 – 1631 1632 – 2100

-5 -6 -7

3 -4 -6

0 1 -5

-5 -5 -1

-4 -4 -5

-8 -8 -9

To inlet duct (2)

0 – 815 816 – 1631 1632 – 2100

-4 -5 -8

3 -4 -7

0 1 -5

-7 -8 -2

-3 -3 -3

To surroundings – the fan inlet and outlet ducted (3)

0 – 815 816 – 1631 1632 – 2100

-13 -14 -15

-6 -11 -13

-7 -7 -9

-10 -10 -8

To fan outlet (open-discharge fan) (4)

0 – 815 816 – 1631 1632 – 2100

-12 -13 -15

0 -7 -9

-1 0 -6

-5 -5 -1

Correction, Kokt, dB Speed range

FIFLO 4249 GB 02.12

47

25 Pa

20

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

Fläkt Woods Oy

1

1

1600

Lwokt(s)=LWA+Kokt(s)

Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)]

m 3/h

25000

600

4

A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

8 m 3/s

7

20000

800

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path:

800 .977

100

P M ,kW

∆p t ,Pa

1000

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz

LWA

LWA(s)

8 000

dB

dB

-14 -14 -14

-17 -17 -17

0 0 0

6.3 4.5 3.1

-9 -9 -9

-11 -13 -12

-14 -14 -14

0.3 0 0.5

6.1 4.5 2.6

-9 -9 -11

-14 -14 -16

-22 -22 -25

-32 -32 -36

-5.7 -5.8 -6.7

4.6 3.5 3.5

-4 -4 -5

-8 -8 -9

-14 -14 -14

-17 -17 -17

-0.2 -0.2 -0.1

4.7 3.6 2.4

1 000 2 000 4 000

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLF-3-071 Dimensions and Weights 723

Right-hand version with 90° direction of discharge shown

678 526

Fan shaft

65

14

458 ø 12 48,5 Max. IEC180

45

525*)

585

723

1297 ø 710 529

1510*) 1560

36*) 59

427

*) Distance between the anti-vibration mountings

50

Right-hand version (viewed from drive side) 898

30

884

898 1331

1124

898

806

639 399 38 222

1619

59

546

427

1858 90°

1643



270°

Left-hand version (same dimensions as the right-hand version)

90°



Weight (kg) GTLF-3-071: 134,0 Belt drive: 6,0

270°

Outlet flange 132 ø10 15

526 232

19,5

15 19,5 15 ø10 4,5

Motor data: See separate motor list.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

4 x 232

937

958

928 898

466 496 505 48

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLF-3-071 Belt-driven, single-inlet, forward-curved blades

1800

69 r/min 850

Impeller diameter: 710 mm

η,%

65

60

65

800 1000

60

700

50

600 40

∆p t ,Pa

500

500 400 95 90

300

200

L wA,dB 85 100

GTLF-3-071

50 2

4 10000

qv

6

15000

10 m 3/s

8

20000

25000

35000 m 3/h

30000

0.5

P,kW

J = 2.20 kgm 2

400

2

600

4

700

Acoustic Data

800 850 r/min

A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

10

10

20 22

18 pd

40

∆p 1

60 15

∆ p 2 + pd

80 100 120

20

30

100

200

40

40

60

Sound path (s)

r/min

63

125

250

500

LWA(s)=LWA+[LwA(s)–LWA]

To outlet duct (1)

0 – 558 559 – 850

-2 -2

-1 0

1 -1

-2 -3

-7 -5

-8 -8

To inlet duct (2)

0 – 558 559 – 850

1 1

-2 -3

-1 -4

-6 -5

-3 -2

To surroundings – the fan inlet and outlet ducted (3)

0 – 558 559 – 850

-14 -15

-6 -8

-4 -8

-3 -7

To fan outlet (open-discharge fan) (4)

0 – 558 559 – 850

-9 -10

-4 -3

0 -2

-2 -3

Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)]

Pa

500 80 80

FIFLO 4249 GB 02.12

49

Pa

100 Pa

Correction, Kokt, dB Speed range

Pa 100 Pa

60

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path:

80 400

40

20

300

60 300

20

∆p 4

160

160 200

∆p 3

Lwokt(s)=LWA+Kokt(s)

Fläkt Woods Oy

2

500

P M ,kW

300 1

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz

LWA

LWA(s)

8 000

dB

dB

-13 -12

-18 -16

0 0

5.7 5.4

-8 -7

-11 -10

-17 -16

0.3 1.0

5.4 4.4

-7 -7

-10 -9

-20 -20

-28 -28

-1.9 -3.0

3.7 2.5

-7 -5

-8 -8

-13 -12

-18 -16

-0.3 -0.2

4.4 3.8

1 000 2 000 4 000

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLB/GTHB-3-071 Dimensions and Weights 723

Right-hand version with 90° direction of discharge shown

678 526

Fan shaft

65

14

458 ø 12 48,5 Max. IEC180

45

525*)

585

723

1297 ø 710 529

1510*) 1560

36*) 59

427

*) Distance between the anti-vibration mountings

50

Right-hand version (viewed from drive side) 898

30

884

898 1331

1124

898

806

639 399 38 222

1619

59

546

427

1858 90°

1643



270°

Left-hand version (same dimensions as the right-hand version)

90°



Weight (kg) GTLB/HB-3-071: 144,0 Belt drive: 10,0

270°

Outlet flange 132 ø10 15

526 232

19,5

15 19,5 15 ø10 4,5

Motor data: See separate motor list.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

4 x 232

937

958

928 898

466 496 505 50

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLB/GTHB-3-071 Belt-driven, single-inlet, backward-curved blades

3500

80

GTHBmax 1900 1800

3000

84

r/min η-korr

GTHB-3-071

η,% GTLB-3-071

1900 1 1800 1

80

Impeller diameter: 710 mm

1600

75

2000

1600 .999

GTLBmax 1450 1400 1400 .998

60 1200 1000

1200 .996

1000

40

∆p t ,Pa

1000 .992

Only the GTLB is available in the smoke extraction version.

800

500

L wA,dB 80

85

90

100

95

105

800 .987

600 r/min

200

600 .974

100 50 0

2 qv

5000

4 10000

6

15000

10 m 3/s

8

20000

25000

35000 m 3/h

30000

0.2 1

600 800

2

2 3

1000

4

4

Acoustic Data

J = 4.5 kgm 2

1200

6

1400 1450

A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

10

8 10

1600 15

1800 1900 r/min

20 22 pd

10

∆p 1

20 5

∆ p 2 + pd

20

60 80 100 10

20

40

∆p 3

Lwokt(s)=LWA+Kokt(s)

30

160 200 40

100 10

∆p 4

200

300

Pa

400

40

60

80

Pa

20

40

60

80

Pa

r/min

63

125

250

500

LWA(s)=LWA+[LwA(s)–LWA]

To outlet duct (1)

0 – 815 816 – 1631 1632 – 1900

-5 -5 -6

2 -6 -6

-1 -1 -4

-4 -4 -2

-4 -3 -4

-9 -9 -9

To inlet duct (2)

0 – 815 816 – 1631 1632 – 1900

-3 -3 -5

2 -5 -6

-1 0 -5

-6 -7 -2

-5 -5 -5

To surroundings – the fan inlet and outlet ducted (3)

0 – 815 816 – 1631 1632 – 1900

-13 -13 -14

-6 -13 -13

-7 -7 -10

-9 -9 -9

To fan outlet (open-discharge fan) (4)

0 – 815 816 – 1631 1632 – 1900

-11 -11 -13

-1 -9 -9

-2 -2 -5

-4 -4 -2

Fläkt Woods Oy

100 Pa

20

Sound path (s)

Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)]

80

Correction, Kokt, dB Speed range

FIFLO 4249 GB 02.12

51

25 Pa

250 300

60

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path:

P M ,kW

P,kW

1

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz

LWA

LWA(s)

8 000

dB

dB

-14 -15 -14

-20 -20 -19

0 0 0

5.6 3.9 3.2

-9 -10 -9

-14 -14 -13

-19 -19 -18

-1.0 -1.3 -0.4

6.6 5.3 3.5

-9 -8 -10

-15 -15 -16

-22 -23 -25

-35 -35 -38

-5.7 -5.3 -6.7

4.7 3.2 3.2

-4 -3 -4

-9 -9 -9

-14 -15 -14

-20 -20 -19

-0.4 0 -0.1

4.3 2.8 2.4

1 000 2 000 4 000

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLB/GTHB-3-080 Dimensions and Weights Right-hand version with 90° direction of discharge shown Fan shaft

1256 40

12

80 70

ø 806

ø90 86

525

8

43

40

Anti-vibration mountings

GTLB: 820 GTHB: 840 GTLB: 770 GTHB: 810

45

40

M10 101

ø 40 h 8

124 151

1470

1510

ø 11,5

1007

872

ø 806

965

50

598 589 494

722

ø 15 633

1216

Right-hand version (viewed from drive side)40

1470

40

40 965

494

494

598

40 40 1555

1515

767

60

30 605

917

1096

550 60

30 1350

605

1096

40

30

60

2045 2210

1791 2000 90°

605

45

45

643

1301

45

1010

1791 2000



270°

Left-hand version (same dimensions as the right-hand version)

90°

Weight (kg) GTLB/HB-3-080: 267,0 Belt drive: 12,0



270°

Outlet flange 212 ø10 15

613 153

212

19,5

15 19,5 15 ø10 4,5

Motor data: See separate motor list.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

5 x 212

1065

1095

1056 1015

533 573 583 52

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLB/GTHB-3-080 3500

Belt-driven, single-inlet, backward-curved blades

r/min 76 GTHBmax 1660 1600

3000

Impeller diameter: 800 mm

80

82

r/min η-korr

GTHB-3-080 GTLB-3-080

η%

1660 1 1600 1

80

1500

1500 .999

75

1400 GTLBmax 1350 1300

2000

1400 .998

70 1300 .997

1200

60

1200 .996

1100 1100 .995

50

1000

1000

1000 .993

900

900 .99

∆p t ,Pa

800

Only the GTLB is available in the smoke extraction version.

L wA,dB 88

700

500

92

100

96

104

108

800 .986 700 .981

600

600 .973

200 100 2

4 qv

10000

6

8

20000

12 m 3/s

10

30000

40000

m 3/h

0.5

2

r/min 600 700 800

JL = 3.10 kgm 2 JH = 4.30 kgm2

2 4

900 1000 1100

Acoustic Data

1200

A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

10

10

1300 1350 1400 1500

20

20

1600 1660

26 pd

30

∆p 1

50

10

100 20

∆ p 2 + pd 40

Lwokt(s)=LWA+Kokt(s)

30

40

100

50

200

70

80

400 Pa

10

20

40

60

Pa

∆p 4

10

20

40

60

Pa

63

125

250

500

LWA(s)=LWA+[LwA(s)–LWA]

To outlet duct (1)

0 – 815 816 – 1631 1632 – 1660

-4 -4 -4

0 -8 -6

-2 -4 -5

-3 -3 -3

-3 -3 -4

-10 -9 -7

To inlet duct (2)

0 – 815 816 – 1631 1632 – 1660

-2 -2 -3

0 -5 -5

-1 -2 -4

-5 -6 -4

-6 -7 -6

To surroundings – the fan inlet and outlet ducted (3)

0 – 815 816 – 1631 1632 – 1660

-11 -11 -10

-7 -16 -13

-9 -11 -12

-8 -9 -10

To fan outlet (open-discharge fan) (4)

0 – 815 816 – 1631 1632 – 1660

-10 -10 -10

-2 -10 -8

-2 -4 -5

-3 -3 -3

Correction, Kokt, dB Speed range

FIFLO 4249 GB 02.12

Pa

∆p 3

r/min

Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)]

60 300

Sound path (s)

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path:

30 Pa

200

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

Fläkt Woods Oy

P M ,kW

P,kW

1

53

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz

LWA

LWA(s)

8 000

dB

dB

-15 -15 -14

-23 -23 -21

0 0 0

5.0 3.3 3.2

-11 -11 -9

-17 -17 -15

-24 -24 -23

-1.8 -2.7 -1.5

6.7 6.0 4.6

-8 -11 -9

-15 -14 -13

-23 -23 -22

-33 -33 -31

-5.1 -6.8 -5.9

3.9 3.2 2.9

-3 -3 -4

-10 -9 -7

-15 -15 -14

-23 -23 -21

0.1 0 0

4.1 2.5 2.4

1 000 2 000 4 000

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLB/GTHB-3-090 Dimensions and Weights Right-hand version with 90° direction of discharge shown Fan shaft

1405 40

14

80 70

ø 911 40

ø90 85

587

9

48,5

Anti-vibration mountings

GTLB: 900 GTHB: 980 GTLB: 831 GTHB: 879

45

40

M10 101

ø 45 h 8

978

124 151

1648

1688

ø 11,5

1130

ø 911

1080

50

670 651 557

809

ø 15 695

1366

Right-hand version (viewed from drive side)

40

1648

40

40

1080

557

557

670

40 40 1734

1693

45

30

854

60

605

1023

1246

614 60

30 1528

605

1246

40

30

60

2223 2390

1940 2150 90°

605

45

715

1454

45

1125

1940 2150



270°

Left-hand version (same dimensions as the right-hand version)

90°

Weight (kg) GTLB/HB-3-090: 320,0 Belt drive: 21,0



270°

Outlet flange 236 ø10 15

675 165

236

19,5

15 19,5 15 ø10 4,5

Motor data: See separate motor list.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

5 x 236

1185

1218

1175 1138

595 632 642 54

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLB/GTHB-3-090 3500

Belt-driven, single-inlet, backward-curved blades

r/min 77 80 GTHBmax 1480

3000

82

η%

1400 1350 1300

Impeller diameter: 900 mm 2000

r/min η-korr

GTHB-3-090 GTLB-3-090

1480 1 1400 1

80

1300 .999

75

GTLBmax 1200

70

1200 .998

1100

1100 .997

60

1000

1000 .996

900

1000

50

900 .994

800 800 .992

Only the GTLB is available in the smoke extraction version.

500

700 .989

600 95

90

L wA,dB 85

600 .983

105

100

500 .975

200 100 2

4

6 qv

10000

8

20000

10

30000

12

15 m 3/s

14

40000

50000

m 3/h

0.5 1 2

1 r/min 600

J L = 4.50 kgm 2 J H = 5.30 kgm 2

P,kW

700

2 4

800

P M ,kW

∆p t ,Pa

700

900

Acoustic Data A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

25 30 35 pd

To outlet duct (1)

20 30 35

50

10

∆ p 2 + pd

LWA(s)=LWA+[LwA(s)–LWA]

Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)]

30

∆p 1

Sound path (s)

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path:

1200 1300 1350 1400 1480

20

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

10

1100

15

Lwokt(s)=LWA+Kokt(s)

Fläkt Woods Oy

1000

10

100 20

40

30

200 40

100

50

200

60

250 70

Pa

80

400 Pa

300

∆p 3

10

20

40

60

Pa

∆p 4

10

20

40

60

Pa

Correction, Kokt, dB Speed range r/min

LWA

LWA(s)

8 000

dB

dB

-15 -14

-20 -20

0 0

4.8 3.5

-11 -10

-17 -17

-23 -22

-1.8 -1.8

3.0 1.7

-8 -11

-14 -13

-23 -22

-30 -30

-5.2 -6.7

3.7 3.3

-3 -3

-9 -8

-15 -14

-20 -20

0 0.1

3.7 2.7

125

250

500

0 – 815 816 – 1480

-3 -4

-1 -6

-2 -3

-4 -4

-3 -3

-9 -8

To inlet duct (2)

0 – 815 816 – 1480

-3 -3

0 -4

-1 -2

-4 -5

-7 -6

To surroundings – the fan inlet and outlet ducted (3)

0 – 815 816 – 1480

-10 -11

-8 -14

-9 -10

-9 -10

To fan outlet (open-discharge fan) (4)

0 – 815 816 – 1480

-8 -9

-3 -8

-2 -3

-4 -4

55

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz 63

FIFLO 4249 GB 02.12

Pa

1 000 2 000 4 000

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLB/GTHB-3-100 Dimensions and Weights Fan shaft 14

90 80

ø 911

Anti-vibration mountings

GTLB: 1005 GTHB: 1005 GTLB: 955 GTHB: 955

9

45,8

50

Right-hand version with 90° direction of discharge shown

ø90 45

85

670

M10 101

ø 45 h 8 1125

1267 1860

ø 911

1176

50

735 657

884

ø 11,5 124 151

ø 15

730 770

1541

Right-hand version (viewed from drive side) 657

657

1860 1176 735 1905 1905

45

780

575 30

1586

1170

929

729 30

1481 30

2116

45

30

1800

217

1234

575 2435

2280

2116 2280

2600 90°

635 30

45

1221



270°

Left-hand version (same dimensions as the right-hand version)

90°

Weight (kg) GTLB/HB-3-100: 367,0 Belt drive: 34,0



270°

Outlet flange 227

770 270

227

27 50

6 x 220 1367

1267

Motor data: See separate motor list.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

ø12

670

56

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLB/GTHB-3-100 r/min 77 80 GTHBmax 1360 1300

3000

Impeller diameter: 1000 mm

80

1200

1300 1

75

1200 .999

70

1100 .999 1000 .998

60

900

900 .997

50

800

1000

1360 1

η%

1100 GTLBmax 1030 1000

2000

r/min η-korr

GTHB-3-100 GTLB-3-100

82.2

∆p t ,Pa

700

Only the GTLB is available in the smoke extraction version.

700 .994

600 L wA,dB 86 500

500

94

90

600 .99

106

102

98

500 .985 400 .976

200 100 2

4

6

2

8

qv

10000 0.5 1

10

12

14

30000

m 3/h 2

JL = 8.40 kgm 2 JH=10.9 kgm2

600

P,kW

18 m 3/s

16

50000

r/min 500

4

700 800 10

Acoustic Data A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: LWA(s)=LWA+[LwA(s)–LWA] where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] Fläkt Woods Oy

10

900 1000 1030 1100

20

20

1200 30

30

1300 1360

40 45 pd

30

∆p 1

5

∆ p 2 + pd

Lwokt(s)=LWA+Kokt(s)

40

50

10

100 20

40

200

30

40

100

50

Pa

60

200

70

80 Pa Pa

300

∆p 3

10

20

40

60

Pa

∆p 4

10

20

40

60

Pa

Correction, Kokt, dB Speed range Sound path (s)

800 .996

r/min

P M ,kW

Belt-driven, single-inlet, backward-curved blades

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz 63

125

250

500

1 000 2 000 4 000

LWA

LWA(s)

8 000

dB

dB

To outlet duct (1)

0 – 815 816 – 1360

-1 -4

-1 -6

-3 -3

-4 -5

-4 -4

-7 -6

-13 -13

-20 -21

0 0

5.0 3.4

To inlet duct (2)

0 – 815 816 – 1360

-2 -3

0 -5

-2 -2

-3 -4

-5 -6

-11 -11

-17 -17

-23 -22

-1.0 -1.7

6.0 5.1

To surroundings – the fan inlet and outlet ducted (3)

0 – 815 816 – 1360

-8 -11

-7 -14

-10 -10

-9 -11

-9 -10

-12 -11

-21 -21

-30 -31

-5.3 -5.8

4.2 2.7

To fan outlet (open-discharge fan) (4)

0 – 815 816 – 1360

-5 -8

-2 -7

-3 -3

-4 -5

-4 -4

-7 -6

-13 -13

-20 -21

0 0

4.0 2.7

FIFLO 4249 GB 02.12

57

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLB-3-112 Dimensions and Weights, motor in line with the fan Outlet flange

Fan shaft 14

115 100

ø 1000

80 710

9

53,5

1120

2099

ø90

ø 15 7 x 150

1220

1120

Anti-vibration mountings

1489

45 810

M10 101 1049

65

710

ø1000

879

835

85

65

ø 50 h 8

1220 2099

4 x 150

85

1040

50

Right-hand version with 90° direction of discharge shown

ø 15

ø 11,5 124 151

1884

120

45

770 810

Right-hand version (viewed from drive side) With motor IEC 132-180 1884

2099 1220

1884 835

835

610

2264

25

1350

1350

25

IEC 132 IEC 160 IEC 180

1385 1214

45 120

120 45

1654 1044

2264

IEC 132 IEC 160 IEC 180

2049

25

1450

775

25

1450

45 120

IEC 132 IEC 160 IEC 180

25

1350

2950

2750

1884

2099 1220

835

25

2750

With motor IEC 200–225 1884

1350

835

610 2264

120 45

1654

25

1044

1450

1450

25

2049

IEC 200 IEC 225

IEC 200 IEC 225 1385

1214

25

1550

1550 3150

2950 90°



775

25

25

45 120

2264

45 120

IEC 200 IEC 225

1450

1450

25

2950 270°

Left-hand version (same dimensions as the right-hand version)

90°



270°

Weight (kg) GTLB-3-112: 353,0 Base frame: 130,0 Belt drive: 40,0 Motor data: See separate motor list. Fläkt Woods Oy

FIFLO 4249 GB 02.12

58

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLB-3-112 Dimensions and Weights, motor placed beside the fan Right-hand version with 90° direction of discharge shown Fan shaft

Outlet flange 14

1040

9

53,5

ø 1000

4 x 150

85 80

85

50

115 100

710

65

ø 50 h 8

1220 2099

ø 15 7 x 150

1220

1120

Anti-vibration mountings

1120

ø90 1489

ø1000

45 879

835

ø 15

1049

2099

M10 101

810

ø 11,5

100 810

124 151

1884

65

710

20

1660

45 20

1700

Right-hand version (viewed from drive side) 2099

1884

1884

1220 610

835

835 2244

2244 2029 1634

30

912

912

30

30

1020

100

755

807

1020 30

90°

45

1024

45 100

100 45

1365 1194



807

240

30 270°

Left-hand version (same dimensions as the right-hand version)

90°



270°

Weight (kg) GTLB-3-112: 353,0 Base frame: 150,0 Belt drive: 40,0 Motor data: See separate motor list. Fläkt Woods Oy

FIFLO 4249 GB 02.12

59

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Notes

Fläkt Woods Oy

FIFLO 4249 GB 02.12

60

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLB-3-112 Belt-driven, single-inlet, backward-curved blades

3000

Impeller diameter: 1120 mm

1100 1

85

η%

1000

2000

r/min η-korr

GTLB-3-112

r/min 83 1100

1000 1

80 900

900 .999

70

800

800 .998

60

700

1000

700 .997

600

∆p t ,Pa

600 .995

Only the GTLB is available in the smoke extraction version.

500

500

L wA,dB 88

92

40 100

96

500 .992

400 400 .987

200 100 2

6

10000

18 m 3/s

14

30000

m 3/h

50000

400

2

4

P,kW

500 J=18.2 kgm2

600

P M ,kW

1

10

qv

700 10

Acoustic Data A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

900

pd

30

∆p 1

LWA(s)=LWA+[LwA(s)–LWA]

To outlet duct (1)

50

10

∆ p 2 + pd

Sound path (s)

Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)]

1100 r/min

30

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path:

20

1000 20

Lwokt(s)=LWA+Kokt(s)

Fläkt Woods Oy

800

10

100 20

40

30

30 35 300 Pa

200 40

100

50

200

60

70

80 90 Pa 400 Pa

300

∆p 3

10

20

40

60

Pa

∆p 4

10

20

40

60

Pa

Correction, Kokt, dB Speed range

Octave band, mid-frequency, Hz

LWA

LWA(s)

8 000

dB

dB

-14 -13 -14

-27 -24 -25

0 0 0

6,2 6,5 4,9

-7 -8 -8

-14 -13 -14

-27 -24 -25

0 0 0

6,2 6,5 4,9

-11 -10 -10

-12 -13 -13

-22 -21 -22

-37 -34 -35

-6,1 -5,4 -5,7

5,5 5,8 4,0

-5 -5 -5

-7 -8 -8

-14 -13 -14

-27 -24 -25

0 -0,1 0

4,8 5,6 4,4

63

125

250

500

0 – 400 401 – 800 801 – 1100

2 0 -4

-1 2 -2

-2 -1 0

-3 -3 -2

-5 -5 -5

-7 -8 -8

To inlet duct (2)

0 – 400 401 – 800 801 – 1100

2 0 -4

-1 2 -2

-2 -1 0

-3 -3 -2

-5 -5 -5

To surroundings – the fan inlet and outlet ducted (3)

0 – 400 401 – 800 801 – 1100

-5 -7 -11

-8 -4 -10

-9 -8 -7

-10 -8 -8

To fan outlet (open-discharge fan) (4)

0 – 400 401 – 800 801 – 1100

-2 -4 -8

-2 1 -3

-2 -1 0

-3 -3 -2

FIFLO 4249 GB 02.12

r/min

61

LWA(s) – LWt(s) –

1 000 2 000 4 000

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLB-3-125 Dimensions and Weights, motor in line with the fan Outlet flange

Fan shaft 14

115 100

ø 1120

80 800

9

53,5

986

1250

2357

ø90

ø 15 8 x 150

1350

1250

Anti-vibration mountings

1682

55

55

ø 50 h 8

1371 2357

5 x 150

55

1140

50

Right-hand version with 90° direction of discharge shown

55

800

ø1120 63

900 920

M12 ø 14,5

1179

ø 15

120 150

2099

120

63

860 900

Right-hand version (viewed from drive side) With motor IEC 132-180 2099

2357 1371

2099 920

920

675

2540

25

1450

1450

25

IEC 132 IEC 160 IEC 180

1554 1362

63 120

120 63

1865 1169

2540

IEC 132 IEC 160 IEC 180

2282

25

1575

858

25

1575

63 120

IEC 132 IEC 160 IEC 180

25

1450

3200

2950

2099

2357 1371

920

25

2950

With motor IEC 200–225 2099

1450

920

675

120 63

1865

25

1169

1575

1575

25

2540

IEC 200 IEC 225 IEC 250

2282

IEC 200 IEC 225 IEC 250

1554 1362

25

3200 90°

1675

1675 3400 0°

858

25

25

63 120

2540

63 120

IEC 200 IEC 225 IEC 250

1575

1575 3200 270°

Left-hand version (same dimensions as the right-hand version)

90°



270°

Weight (kg) GTLB-3-125: 421,0 Base frame: 140,0 Belt drive: 40,0 Motor data: See separate motor list. Fläkt Woods Oy

FIFLO 4249 GB 02.12

62

Specifications are subject to alteration without notice

25

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLB-3-125 Dimensions and Weights, motor placed beside the fan Right-hand version with 90° direction of discharge shown Fan shaft

Outlet flange 14

1140

9

53,5

ø 1120

5 x 150

55 80

55

50

115 100

800

55

ø 50 h 8

1371 2357

1350

1250

Anti-vibration mountings

ø 15 8 x 150

1250

ø90 1682

ø1120

63

986

ø 15

1179

900

120 150

2099

2357 900

M12 ø 14,5 920

55

800

25

1755

63

120

25

1805

Right-hand version (viewed from drive side) With motor IEC 132-250 2357

2099

2099

1371 675

920

920 2540

2540 2282 1865

30

1020

1020

30

30

1149

120

858

907

1149 30

90°

63

1169

63 120

120 63

1554 1362



907

255

30 270°

Left-hand version (same dimensions as the right-hand version)

90°



270°

Weight (kg) GTLB-3-125: 421,0 Base frame: 190,0 Belt drive: 40,0 Motor data: See separate motor list. Fläkt Woods Oy

FIFLO 4249 GB 02.12

63

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Notes

Fläkt Woods Oy

FIFLO 4249 GB 02.12

64

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLB-3-125 Belt-driven, single-inlet, backward-curved blades

3000 r/min 83 1000

Impeller diameter: 1250 mm

1000 1

η%

900

2000

r/min η-korr

GTLB-3-125 85

900 1

80 800

800 .999

70 700 60 1000

700 .998

600 600 .997

∆p t ,Pa

500

Only the GTLB is available in the smoke extraction version.

40

500 400

L wA,dB 88

92

96

500 .995

100

400 .992

200 100 2

6

10

qv 20000

14

18

40000

24 m 3/s

22

60000

m 3/h

80000

1

500 5

10 600

800 20 900 30

pd

30

∆p 1

Sound path (s)

LWA(s)=LWA+[LwA(s)–LWA]

To outlet duct (1)

35

50

10

∆ p 2 + pd

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

30

1000 r/min

40

Lwokt(s)=LWA+Kokt(s)

Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)]

700 20

A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path:

5

J = 36.6 kgm 2

10

Acoustic Data

Fläkt Woods Oy

400

P M ,kW

P,kW

2

100 20

40

30

100

200 40

50

300

60

200

80 300

100 Pa Pa

400

∆p 3

10

20

40

60

80

Pa

∆p 4

10

20

40

60

80

Pa

Correction, Kokt, dB Speed range r/min

LWA

LWA(s)

8 000

dB

dB

-14 -13 -14

-27 -24 -25

0 0 0

6,2 6,5 4,9

-7 -8 -8

-14 -13 -14

-27 -24 -25

0 0 0

6,2 6,5 4,9

-11 -10 -10

-12 -13 -13

-22 -21 -22

-37 -34 -35

-6,1 -5,4 -5,7

5,5 5,8 4,0

-5 -5 -5

-7 -8 -8

-14 -13 -14

-27 -24 -25

0 -0,1 0

4,8 5,6 4,4

125

250

500

0 – 400 401 – 800 801 – 1000

2 0 -4

-1 2 -2

-2 -1 0

-3 -3 -2

-5 -5 -5

-7 -8 -8

To inlet duct (2)

0 – 400 401 – 800 801 – 1000

2 0 -4

-1 2 -2

-2 -1 0

-3 -3 -2

-5 -5 -5

To surroundings – the fan inlet and outlet ducted (3)

0 – 400 401 – 800 801 – 1000

-5 -7 -11

-8 -4 -10

-9 -8 -7

-10 -8 -8

To fan outlet (open-discharge fan) (4)

0 – 400 401 – 800 801 – 1000

-2 -4 -8

-2 1 -3

-2 -1 0

-3 -3 -2

65

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz 63

FIFLO 4249 GB 02.12

40 45 Pa

1 000 2 000 4 000

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLB-3-140 Dimensions and Weights, motor in line with the fan Outlet flange

Fan shaft 18

130 100

ø 1250

80 900

11

64

ø 15 9 x 150

1500

1400

Anti-vibration mountings

1400

2660

ø90

1910

105

55

ø 60 h 8

1550 2660

5 x 150

105

1220

50

Right-hand version with 90° direction of discharge shown

55

900

ø1250 63

1110

1000 1010

M12 ø 14,5

1330

ø 15

120 150

2340

140

63

965 1000

Right-hand version (viewed from drive side) With motor IEC 132-180 2340

2660 1550

2340 1010

1010

750

2863

30

1570

1570

30

IEC 132 IEC 160 IEC 180

1752 1533

63 140

140 63

2113 1313

2863

IEC 132 IEC 160 IEC 180

2543

30

1720

953

30

1720

63 140

IEC 132 IEC 160 IEC 180

30

1570

3500

3200

2340

2660 1550

1010

30

3200

With motor IEC 200–225 2340

1570

1010

750

140 63

2113

30

1313

1720

1720

30

2863

IEC 200 IEC 225 IEC 250

2543

IEC 200 IEC 225 IEC 250

1752 1533

30

3500 90°

1820

1820 3700 0°

953

30

30

63 140

2863

63 140

IEC 200 IEC 225 IEC 250

1720

1720 3500 270°

Left-hand version (same dimensions as the right-hand version)

90°



270°

Weight (kg) GTLB-3-140: 555,0 Base frame: 180,0 Belt drive: 50,0 Motor data: See separate motor list. Fläkt Woods Oy

FIFLO 4249 GB 02.12

66

Specifications are subject to alteration without notice

30

Centrimaster GT-3

CATALOGUE

Dimensions and Weights – GTLB-3-140 Dimensions and Weights, motor placed beside the fan Right-hand version with 90° direction of discharge shown Fan shaft

Outlet flange 18

1220

11

64

ø 1250

5 x 150

105 80

105

50

130 100

900

55

ø 60 h 8

1550 2660

ø 15 9 x 150

1500

1400

Anti-vibration mountings

1400

ø90 1910

ø1250

63

1110

ø 15

1330

140 1000

120 150

2340

2660 1000

M12 ø 14,5 1010

55

900

30

1875

63 30

1935

Right-hand version (viewed from drive side) 2660

2340

2340

1550 750

1010

1010 2863

2863 2543 2113

30

1140

1140

30

30

1300

140

953

1021

1300 30

90°

63

1313

63 140

140 63

1753 1533



1021

268

30 270°

Left-hand version (same dimensions as the right-hand version)

90°



270°

Weight (kg) GTLB-3-140: 555,0 Base frame: 240,0 Belt drive: 50,0 Motor data: See separate motor list. Fläkt Woods Oy

FIFLO 4249 GB 02.12

67

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Notes

Fläkt Woods Oy

FIFLO 4249 GB 02.12

68

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Fan Charts – Acoustic Data – GTLB-3-140 3000

Belt-driven, single-inlet, backward-curved blades

r/min 83 900

r/min η-korr

GTLB-3-140

85

900 1

η%

Impeller diameter: 1400 mm

800

2000

80

800 1

700 70 700 .999

600

60

1000

600 .998

∆p t ,Pa

500

Only the GTLB is available in the smoke extraction version.

40

400

500

500 .997

L wA,dB 85

90

95

100 400 .995

200 100

Note: Max. speed of the smoke extraction version is 870 rpm.

2

6

10 qv

20000

14

40000

18

22

60000

30 m 3/s

26

80000

100000

m 3/h

2

P,kW

6

J = 61.4 kgm 2

10

500

10

20

600

Acoustic Data

700

20

A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path:

30 800

30 40

40 900

50

r/min

60

60 pd

30

∆p 1

5

∆ p 2 + pd

Lwokt(s)=LWA+Kokt(s)

50

10

100 20

40

30

40

100

50

70

80

400 Pa

300

10

20

40

60

Pa

∆p 4

10

20

40

60

Pa

63

125

250

500

LWA(s)=LWA+[LwA(s)–LWA]

To outlet duct (1)

0 – 400 401 – 800 801 – 900

2 0 -4

-1 2 -2

-2 -1 0

-3 -3 -2

-5 -5 -5

-7 -8 -8

To inlet duct (2)

0 – 400 401 – 800 801 – 900

2 0 -4

-1 2 -2

-2 -1 0

-3 -3 -2

-5 -5 -5

To surroundings – the fan inlet and outlet ducted (3)

0 – 400 401 – 800 801 – 900

-5 -7 -11

-8 -4 -10

-9 -8 -7

-10 -8 -8

To fan outlet (open-discharge fan) (4)

0 – 400 401 – 800 801 – 900

-1 -3 -7

-2 1 -3

-2 -1 0

-3 -3 -2

Correction, Kokt, dB Speed range

FIFLO 4249 GB 02.12

Pa

∆p 3

r/min

Fläkt Woods Oy

60

200

Sound path (s)

Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)]

70 Pa

200

where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path:

where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path:

69

P M ,kW

400

4

LWA(s) – LWt(s) –

Octave band, mid-frequency, Hz

LWA

LWA(s)

8 000

dB

dB

-14 -13 -14

-27 -24 -25

0 0 0

6,2 6,5 4,9

-7 -8 -8

-14 -13 -14

-27 -24 -25

0 0 0

6,2 6,5 4,9

-11 -10 -10

-12 -13 -13

-22 -21 -22

-37 -34 -35

-5 -5 -5

-7 -8 -8

-14 -13 -14

-27 -24 -25

1 000 2 000 4 000

-6,1 -5,4 -5,7 0 0 0

5,5 5,8 4,0 5,0 5,6 4,4

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Motor Data – Single-speed Motors, 50 Hz 2 poles = 3000 r/min Size designation

IEC

ABB Motors

Rated output,

Speed,

Ordering code APAL-

kW

r/min

At rated output Current at 400 V, ca A

1)

lst 2) l

Mst M

Mmax M

Efficiency, η%

Power factors, cos ϕ

Weight, kg

71A 71B 80A

M2VA 71A M2VA 71B M2VA 80A

2-90037-c-d 2-90055-c-d 2-90075-c-d

0,37 0,55 0,75

2840 2830 2870

1,05 1,39 1,8

5,5 5,7 6,2

3,8 3,6 2,9

3,9 3,7 3,6

77,1 79,2 81,2

0,77 0,78 0,75

5,5 6,5 9

80B 90S 90L

M2VA 80B M2AA 90S M2AA 90L

2-90110-c-d 2-90150-c-d 2-90220-c-d

1,1 1,5 2,2

2850 2870 2870

2,5 3,35 4,55

6,1 5,5 7

2,3 2,4 2,7

3,5 3,0 3,0

82,2 80,1 80,8

0,78 0,82 0,86

11 13 16

100L 112 M 132 SM

M2AA 100L M2AA 112 M M2AA 132 SA

2-90300-c-d 2-00400-c-d 2-00550-c-d

3 4 5,5

2900 2850 2855

5,95 7,4 10,5

7,5 7,5 7,8

2,7 2,8 3,2

3,6 3 3,4

86 86 86

0,88 0,91 0,88

21 25 37

132 S 160 M 160 M

M2AA 132 SB M2AA 160 MA M2AA 160 M

2-00750-c-d 2-01100-c-d 2-01500-c-d

7,5 11 15

2855 2930 2920

13,9 20 26,5

8,5 6,3 6,6

3,4 1,9 2,3

3,6 2,5 2,5

87 91,2 91,7

0,90 0,88 0,90

42 73 84

160 L 180 M 200 ML

M2AA 160 L M2AA 180 M M2AA 200 MLA

2-01850-c-d 2-02200-c-d 2-03000-c-d

18,5 22 30

2920 2930 2955

32 38,5 53

7,3 7,2 7,3

2,6 2,5 2,4

2,7 2,7 3,1

92,4 92,8 93,2

0,91 0,89 0,88

94 119 175

200 ML 225 SM 250 SM

M2AA 200 MLB M2AA 225 SMB M2AA 250 SMA

2-03700-c-d 2-04500-c-d 2-05500-c-d

37 45 55

2950 2960 2970

64 79 95

7,3 7,3 7,5

2,5 2,5 2

3,2 2,8 3

93,6 93,9 94,4

0,89 0,88 0,89

200 235 285

280 S 280 SM 315 S

M2CA 280 SA M2CA 280 SMA M2CA 315 SA

2-07500-c-d 2-09000-c-d 2-11000-c-d

75 90 110

2977 2975 2982

131 152 194

7,4 7,2 7,6

2 2,1 2

2,9 2,7 3

94,9 95,3 95,5

0,88 0,90 0,86

480 545 695

315 SM 315 M

M2CA 315 SMA M2CA 315 MB

2-13200-c-d 2-16000-c-d

132 160

2982 2981

228 269

7,4 7,5

2,2 2,3

3 3

95,7 96,1

0,88 0,89

770 840

1) Correction factors The current values in the tables are applicable to motors wound for 400 V. All motors can be used for voltages between 380 and 420 V. Motors with voltage code c=1 can be connected in delta to operate in the range of 220–240 V. Motors with voltage code c=2 can be connected in star to operate in the range of 660–690 V. The correction factors on the current in the range of 400 V will then be: 220–240 V = 1.73 and 660–690 V = 0.58.

Code suffix for voltage (c) 1 = 220–240 V delta/380–420 V star

The motors can also be wound for 500 V, and the voltage code is then c=5. The correction factor on the current at 400 V is then 0.8.

5 = 500 V star (sizes 71–100) 500 V delta (sizes 112–315)

The speeds, efficiencies and power factors are applicable at 230, 400, 690 and 500 V.

2)

Temperature sensors in the stator winding, code suffix (d) 0 = without 1 = with bimetal temperature contacts 2 = with thermistor

lst = Ratio of motor starting current to full-load current.

l

Fläkt Woods Oy

FIFLO 4249 GB 02.12

2 = 380–420 V delta/660–690 V star

70

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Motor Data – Single-speed Motors, 50 Hz 4 poles = 1500 r/min Size designation

IEC

ABB Motors

Rated output,

Speed,

Ordering code APAL-

kW

r/min

At rated output Current at 400 V, ca A

1)

lst 2) l

Mst M

Mmax M

Efficiency, η%

Power factors, cos ϕ

Weight, kg

71A 71B 80A

M2VA 71A M2VA 71B M2VA 80A

4-90025-c-d 4-90037-c-d 4-90055-c-d

0,25 0,37 0,55

1410 1420 1390

0,78 1,05 1,55

4,3 4,4 4,6

2,7 2,6 2,6

2,9 2,8 2,9

70,4 74,6 75,3

0,71 0,69 0,71

5,5 6,5 9

80B 90S 90L

M2VA 80B M2AA 90S M2AA 90L

4-90075-c-d 4-90110-c-d 4-90150-c-d

0,75 1,1 1,5

1400 1410 1420

2,15 2,59 3,45

4,7 5 5

3,5 2,2 2,4

3,9 2,7 2,9

78,2 77,5 80,3

0,66 0,81 0,79

10,5 13 16

100LA 100LB 112 M

M2AA100 LA M2AA100 LB M2AA 112 M

4-90220-c-d 4-90300-c-d 4-00400-c-d

2,2 3 4

1430 1430 1435

4,8 6,48 8,6

5,5 5,5 7

2,4 2,5 2,9

2,9 2,9 3,1

83 85 85

0,81 0,81 0,80

21 24 27

132 S 132 M 160 M

M2AA 132 S M2AA 132 M M2AA 160 M

4-00550-c-d 4-00750-c-d 4-01100-c-d

5,5 7,5 11

1450 1450 1460

11,1 14,8 21,5

7,3 7,9 6,7

2,2 2,5 2,9

3 3,2 2,8

87 88 90,3

0,83 0,83 0,81

40 48 75

160 L 180 M 180 L

M2AA 160 L M2AA 180 M M2AA 180 L

4-01500-c-d 4-01850-c-d 4-02200-c-d

15 18,5 22

1455 1470 1470

28,5 35 41

6,8 7 7

3 3,1 2,9

2,8 2,7 2,8

91,1 92,3 92,4

0,84 0,84 0,83

94 124 141

200 ML 225 SM 225 SM

M2AA 200 MLA M2AA 225 SMA M2AA 225 SMB

4-03000-c-d 4-03700-c-d 4-04500-c-d

30 37 45

1475 1480 1480

56 68 83

6,7 6,6 6,7

2,6 2,4 2,7

2,8 2,5 2,6

92,9 93,6 94,2

0,83 0,84 0,83

180 215 230

250 SM 280 S 280 SM

M2AA 250 SMA M2CA 280 SA M2CA 280 SMA

4-05500-c-d 4-07500-c-d 4-09000-c-d

55 75 90

1480 1483 1484

98 137 163

7,5 6,9 7,6

2,3 2,2 2,5

2,8 2,8 2,9

94,6 94,6 95

0,86 0,84 0,85

275 445 490

315 S 315 SM 315 M

M2CA 315 SA M2CA 315 SMA M2CA 315 MB

4-11000-c-d 4-13200-c-d 4-16000-c-d

110 132 160

1487 1486 1486

198 238 282

6,5 7,3 7

2,1 2,2 2,4

2,6 2,7 2,7

95,4 95,6 96

0,85 0,85 0,86

675 730 850

1) Correction factors The current values in the tables are applicable to motors wound for 400 V. All motors can be used for voltages between 380 and 420 V. Motors with voltage code c=1 can be connected in delta to operate in the range of 220–240 V. Motors with voltage code c=2 can be connected in star to operate in the range of 660–690 V. The correction factors on the current in the range of 400 V will then be: 220–240 V = 1.73 and 660–690 V = 0.58. The motors can also be wound for 500 V, and the voltage code is then c=5. The correction factor on the current at 400 V is then 0.8 .

Code suffix for voltage (c) 1 = 220–240 V delat/380–420 V star 2 = 380–420 V delta/660–690 V star 5 = 500 V star (sizes 71–100) 500 V delta (sizes 112–315) Temperature sensors in the stator winding, code suffix (d) 0 = without 1 = with bimetal temperature contacts 2 = with thermistor

The speeds, efficiencies and power factors are applicable at 230, 400, 690 and 500 V. 2)

lst = Ratio of motor starting current to full-load current.

l

Fläkt Woods Oy

FIFLO 4249 GB 02.12

71

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Motor Data – Single-speed Motors, 50 Hz 6 poles = 1000 r/min Size designation

IEC

ABB Motors

Rated output,

Speed,

Ordering code APAL-

kW

r/min

At rated output Current at 400 V, ca A

1)

lst 2) l

Mst M

Mmax M

Efficiency, η%

Power factors, cos ϕ

Weight, kg

71A 71B 80A

M2VA 71A M2VA 71B M2VA 80A

6-90018-c-d 6-90025-c-d 6-90037-c-d

0,18 0,25 0,37

920 920 915

0,65 0,86 1,15

2,9 3,2 3,8

2,1 2,5 3,1

2,2 2,7 3,4

61,1 64,9 72,9

0,69 0,64 0,65

80B 90S 90L

M2VA 80B M2AA 90S M2AA 90L

6-90055-c-d 6-90075-c-d 6-90110-c-d

0,55 0,75 1,1

900 930 930

1,72 2,36 3,25

3,4 4 4

2,9 1,9 1,9

3,1 2,3 2,3

73,3 71,5 74,4

0,64 0,67 0,69

10 13 16

100L 112 M 132 S

M2AA 100L M2AA 112 M M2AA 132 S

6-90150-c-d 6-00220-c-d 6-00300-c-d

1,5 2,2 3

950 940 960

3,92 5,4 6,9

4,5 5,6 6,1

1,9 2,1 2,4

2,3 2,7 2,6

80 80,5 84,5

0,71 0,74 0,75

23 27 39

132 M 132 M 160 M

M2AA 132 MA M2AA 132 MB M2AA 160 M

6-00400-c-d 6-00550-c-d 6-00750-c-d

4 5,5 7,5

960 955 970

8,7 11,9 15,4

7,1 6,9 6,7

2,6 2,8 2

2,8 2,8 2,8

85,5 86 89,3

0,78 0,78 0,79

46 54 88

160 L 180 L 200 ML

M2AA 160 L M2AA 180 L M2AA 200 MLA

6-01100-c-d 6-01500-c-d 6-01850-c-d

11 15 18,5

970 970 985

23 31 36

7,1 7 7

2,2 2,1 2,5

2,9 3 2,7

89,8 90,8 91,1

0,78 0,78 0,81

102 151 165

200 ML 225 SM 250 SM

M2AA 200 MLB M2AA 225 SMB M2AA 250 SMA

6-02200-c-d 6-03000-c-d 6-03700-c-d

22 30 37

980 985 985

43 56 69

7,2 6,6 7,3

2,5 2,5 2,8

2,7 2,7 2,8

91,7 92,8 93,7

0,81 0,83 0,83

185 225 280

280 S 280 SM 315 S

M2CA 280 SA M2CA 280 SMA M2CA 315 SA

6-04500-c-d 6-05500-c-d 6-07500-c-d

45 55 75

990 989 990

85 102 143

7 7 6,8

2,6 2,7 2,2

2,6 2,6 2,6

94,2 94,5 94,7

0,82 0,83 0,81

440 475 630

315 SM 315 M

M2CA 315 SMA M2CA 315 MB

6-09000-c-d 6-11000-c-d

90 110

989 988

163 198

7 6,8

2,3 2,4

2,5 2,5

95,2 95,3

0,84 0,84

720 805

1) Correction factors The current values in the tables are applicable to motors wound for 400 V. All motors can be used for voltages between 380 and 420 V. Motors with voltage code c=1 can be connected in delta to operate in the range of 220–240 V. Motors with voltage code c=2 can be connected in star to operate in the range of 660–690 V. The correction factors on the current in the range of 400 V will then be: 220–240 V = 1.73 and 660–690 V = 0.58. The motors can also be wound for 500 V, and the voltage code is then c=5. The correction factor on the current at 400 V is then 0.8. The speeds, efficiencies and power factors are applicable at 230, 400, 690 and 500 V.

2)

5,5 6,5 9

Code suffix for voltage (c) 1 = 220–240 V delta/380–420 V star 2 = 380–420 V delta/660–690 V star 5 = 500 V star (sizes 71–100) 500 V delta (sizes 112–315)

Temperature sensors in the stator winding, code suffix (d) 0 = without 1 = with bimetal temperature contacts 2 = with thermistor

lst = Ratio of motor starting current to full-load current.

l

Fläkt Woods Oy

FIFLO 4249 GB 02.12

72

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Motor Data – Single-speed Motors, 50 Hz 8 poles = 750 r/min Size designation

IEC

ABB Motors

Rated output,

Speed,

Ordering code APAL-

kW

r/min

At rated output Current at 400 V, ca A

1)

lst 2) l

Mst M

Mmax M

Efficiency, η%

Power factors, cos ϕ

Weight, kg

80 A 80 B 90 S

M2VA 80A M2VA 80B M2AA 90S

8-90018-c-d 8-90025-c-d 8-90037-c-d

0,18 0,25 0,37

700 680 700

0,85 0,95 1,6

3,1 3,1 3

3,2 2,9 1,9

3,6 3,1 2,4

59,9 70,7 61,5

0,53 0,56 0,56

10 10,5 13

90 L 100 L 100 L

M2AA 90L M2AA 100LA M2AA 100LB

8-90055-c-d 8-90075-c-d 8-90110-c-d

0,55 0,75 1,1

690 700 700

2,35 2,55 3,35

3 3,5 3,5

1,7 2,1 2,1

2,1 2,7 2,7

62,9 72 73

0,57 0,59 0,64

16,5 20 22

112 M 132 S 132 M

M2AA 112 M M2AA 132 S M2AA 132 M

8-00150-c-d 8-00220-c-d 8-00300-c-d

1,5 2,2 3

695 720 720

4,5 5,9 7,8

4,1 5,3 5,5

1,9 1,9 2,4

2,4 2,5 2,6

75 81 82

0,65 0,67 0,68

28 46 53

160 M 160 M 160 L

M2AA 160 MA M2AA 160 M M2AA 160 L

8-00400-c-d 8-00550-c-d 8-00750-c-d

4 5,5 7,5

715 710 715

10 13,4 18,1

5,2 5,4 5,4

2,1 2,4 2,4

2,4 2,6 2,8

84 85 86

0,69 0,70 0,70

75 88 118

180 L 200 ML 225 SM

M2AA 180 L M2AA 200 MLA M2AA 225 SMA

8-01100-c-d 8-01500-c-d 8-01850-c-d

11 15 18,5

720 740 730

23,5 29 37

5,9 7,4 6,2

2,4 1,8 1,9

2,6 3 2,7

89 91,1 91,1

0,76 0,82 0,79

147 175 210

225 SM 250 SM 280 S

M2AA 225 SMB M2AA 250 SMA M2CA 280 SA

8-02200-c-d 8-03000-c-d 8-03700-c-d

22 30 37

730 735 741

45 59 74

6 6,9 6,8

1,9 1,9 1,6

2,7 2,9 2,7

91,5 92,8 93

0,77 0,79 0,78

225 280 460

280 SM 315 S 315 SM

M2CA 280 SMA M2CA 315 SA M2CA 315 SMA

8-04500-c-d 8-05500-c-d 8-07500-c-d

45 55 75

741 741 740

90 107 142

7,1 7,1 7,1

1,8 1,8 1,8

2,8 2,8 2,8

93,5 94 94,5

0,78 0,80 0,81

500 630 715

315 M

M2CA 315 MB

8-09000-c-d

90

740

169

7,3

1,9

2,8

94,7

0,82

800

1) Correction factors The current values in the tables are applicable to motors wound for 400 V. All motors can be used for voltages between 380 and 420 V.

Code suffix for voltage (c) 1 = 220–240 V delta/380–420 V star

Motors with voltage code c=1 can be connected in delta to operate in the range of 220–240 V. Motors with voltage code c=2 can be connected in star to operate in the range of 660–690 V. The correction factors on the current in the range of 400 V will then be: 220–240 V = 1.73 and 660–690 V = 0.58.

2 = 380–420 V delta/660–690 V star

The motors can also be wound for 500 V, and the voltage code is then c=5. The correction factor on the current at 400 V is then 0.8.

Temperature sensors in the stator winding, code suffix (d) 0 = without 1 = with bimetal temperature contacts 2 = with thermistor

The speeds, efficiencies and power factors are applicable at 230, 400, 690 and 500 V.

2)

lst = Ratio of motor starting current to full-load current.

l

Fläkt Woods Oy

FIFLO 4249 GB 02.12

5 = 500 V star (sizes 71–100) 500 V delta (sizes 112–315)

73

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Motor Data – Two-speed Motors, 50 Hz 2/4 poles = 3000/1500 r/min One stator winding (Dahlander wound) Size designation

IEC

ABB Motors

No. of Ordering code motor ARAL-2poles

Rated output,

Speed,

kW

r/min

At rated output Current at 400 V, ca A

1)

lst 2) l

Mst M

Mmax M

Efficiency, η%

Power factors, cos ϕ

Weight, kg

71

M2VA 71 B

90055-c-d

2 4

0,55 0,12

2700 1470

1,3 0,75

3,8 3,4

1,4 2,2

1,5 2,3

67 55

0,91 0,42

6,5

80

M2VA 80 A

90075-c-d

2 4

0,75 0,15

2850 1430

1,8 0,65

4,9 3,9

2,2 2,4

2,3 2,5

73 52

0,83 0,65

9

80

M2VA 80 B

90110-c-d

2 4

1,1 0,25

2840 1430

2,6 0,9

4,9 3,9

2,2 2,2

2,3 2,3

73 60

0,84 0,67

11

90 S

M2AA 90 S

90150-c-d

2 4

1,5 0,33

2860 1460

3,3 1,1

5,2 3,9

1,8 1,1

2,4 2,1

77 66

0,87 0,67

13

90 L

M2AA 90 L

90220-c-d

2 4

2,2 0,45

2860 1460

4,6 1,4

5,9 4,4

2,1 1,2

2,6 2,3

80 73

0,88 0,65

16

100 L

M2AA 100 LB

90350-c-d

2 4

3,5 0,7

2880 1470

7 2

6,2 4,8

2,1 1,2

2,6 3

80 77

0,91 0,65

25

112 M

M2AA 112 M

00451-c-d

2 4

4,5 1

2875 1450

8,4 2,4

7 6

1,8 1,9

2,3 2,8

83 80

0,93 0,76

32

132 S

M2AA 132 S

00620-c-d

2 4

6,2 1,3

2880 1455

11,8 3,5

7 6,5

2 2,6

2,6 3,3

84 80

0,91 0,67

42

132 M

M2AA 132 M

00830-c-d

2 4

8,3 1,7

2875 1455

15,4 4,2

7,4 6,6

2,5 2,7

2,7 3,3

84 82

0,93 0,71

56

160 M

M2AA 160MA

01000-c-d

2 4

10 2

2910 1465

19 4,8

5,9 6,1

1,5 2,4

2,3 2,8

85 83,5

0,89 0,73

73

160 M

M2AA 160 M

01600-c-d

2 4

16 3,2

2915 1465

28,5 7

6,6 6,3

1,8 2,5

2,4 2,8

87,5 86,5

0,92 0,76

94

160 L

M2AA 160 L

01950-c-d

2 4

19,5 4,5

2930 1465

36 9,7

7,6 6,4

2,3 2,5

2,9 2,8

89 88

0,89 0,77

100

180 M

M2AA 180 M

02150-c-d

2 4

21,5 4,7

2935 1465

38 10

7 5,3

2,1 2,1

2,6 2,3

90 88

0,91 0,77

137

180 L

M2AA 180 L

02600-c-d

2 4

26 5,2

2940 1470

47 11

6,9 5,8

2,3 2,4

2,6 2,4

90,5 89,5

0,89 0,75

151

200 ML

M2AA 200 MLA

03200-c-d

2 4

32 8

2940 1465

58 16

7,1 6,2

2 2

2,5 2,2

90 89

0,89 0,85

180

200 ML

M2AA 200 MLB

03900-c-d

2 4

39 10

2950 1475

69 19

7,4 6,2

2 2

2,6 2,3

91,5 91

0,89 0,85

205

200 ML

M2AA 200 MLC

04200-c-d

2 4

42 11

2950 1470

75 23

7,7 5,6

2,2 2,1

3 2,5

92,5 91

0,89 0,77

205

225 SM

M2AA 225 SMB

04500-c-d

2 4

45 13

2955 1475

76 25

7,4 5,3

2 2

2,6 2,1

93 91,5

0,92 0,82

235

225 SM

M2AA 225 SMC

05500-c-d

2 4

55 15

2955 1475

94 29

7,3 5,4

2 2

2,6 2,2

93,5 92,5

0,91 0,82

260

250 SM

M2AA 250 SMB

07500-c-d

2 4

75 25

2955 1475

125 48

8,9 5,5

2,3 2

3,1 2,2

94,5 93

0,92 0,82

330

Code suffix for voltage (c) 1) Correction factors Correction factors for current at other voltages: 230 V = 1.74 ; 500 V = 0.80 The speeds, efficiencies and power factors are applicable at 230, 400 and 500 V. l 2) st = Ratio of motor starting current to full-load current l

Fläkt Woods Oy

FIFLO 4249 GB 02.12

V (sizes 71–132) 1 = 220–230 230 V (sizes 160–250) V (sizes 112–132) 2 = 380–400 400 V (sizes 160–315) V (sizes 71–100) 4 = 400–415 415 V (sizes 160–315) 5 = 500 V

74

(sizes 71–315)

Temperature sensors in the stator winding, code suffix (d) 0 = without 1 = with bimetal temperature contacts 2 = with thermistor

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Motor Data – Two-speed Motors, 50 Hz 4/6 poles = 1500/1000 r/min Two separate windings Size designation

IEC

ABB Motors

No. of Ordering code motor ATAL-4poles

Rated output,

Speed,

kW

r/min

At rated output Current at 400 V, ca A

1)

lst 2) l

Mst M

Mmax M

Efficiency, η%

Power factors, cos ϕ

Weight, kg

71

M2VA 71 B

90030-c-d

4 6

0,3 0,1

1350 900

0,9 0,6

2,8 2

1 1,05

1,1 1,15

54 30

0,86 0,79

6,5

80

M2VA 80 A

90045-c-d

4 6

0,45 0,15

1390 945

1,2 0,7

3,2 3

1,6 1,5

1,7 1,6

65 42

0,85 0,75

10

80

M2VA 80 B

90075-c-d

4 6

0,75 0,22

1400 955

1,9 0,9

3,3 3,2

1,7 1,6

1,8 1,7

67 48

0,86 0,74

10,5

90 S

M2AA 90 S

90100-c-d

4 6

1 0,3

1400 940

2,5 1,2

4,3 2,6

1,8 1

2,2 1,7

73 53

0,83 0,7

13

90 L

M2AA 90 L

90150-c-d

4 6

1,5 0,45

1400 930

3,5 1,6

4,3 2,9

1,7 1

2,1 1,8

72 52

0,84 0,73

16

100 L

M2AA 100 LA

90200-c-d

4 6

2 0,6

1430 960

4,5 2

5 3,3

1,8 1

2,4 1,9

77 62

0,85 0,72

20

100 L

M2AA 100 LB

90250-c-d

4 6

2,5 0,8

1430 960

5,5 2,5

5,6 3,5

2 1,1

2,5 2

79 68

0,84 0,71

23

112 M

M2AA 112 M

00300-c-d

4 6

3 1

1445 975

6,3 3,1

6 4

1,3 1

2,3 2,2

82 67

0,84 0,68

33

132 S

M2AA 132 S

00450-c-d

4 6

4,5 1,5

1460 985

9,2 5,1

6,5 4,2

1,5 1

2,3 2,2

83 67

0,85 0,64

48

132 M

M2AA 132 M

00600-c-d

4 6

6 2

1460 980

12 5,6

7,1 4,5

1,8 1,3

2,5 2

84 71

0,86 0,73

59

160 M

M2AA 160 M

01050-c-d

4 6

10,5 3,5

1460 965

21 8,6

6,4 4,1

2 1,3

2,5 1,7

87 75,5

0,84 0,78

94

160 L

M2AA 160 L

01450-c-d

4 6

14,5 4,5

1460 970

28 11

6,9 4,6

2,2 1,5

2,6 1,9

88,5 77

0,85 0,76

117

180 M

M2AA 180 M

01601-c-d

4 6

16 5

1470 980

31 12,5

6,3 4,6

1,9 1,5

2,5 2

89 78

0,83 0,73

137

180 L

M2AA 180 L

02001-c-d

4 6

20 6,5

1470 980

39 16

7,2 5

2,4 1,8

2,7 2

90 79,5

0,83 0,74

161

200 ML

M2AA 200 MLA

02300-c-d

4 6

23 7,2

1475 985

43 15

7,7 7,8

1,6 1,9

2,8 2,9

89,5 84

0,88 0,87

175

200 ML

M2AA 200 MLB

03000-c-d

4 6

30 9

1470 985

54 18

7,7 7,9

1,6 1,7

2,7 2,5

90 83,5

0,90 0,89

200

225 SM

M2AA 225 SMB

03400-c-d

4 6

34 11

1470 985

60 21

7,7 6,7

1,5 1,3

2,7 2,3

91 85

0,91 0,89

225

225 SM

M2AA 225 SMC

04200-c-d

4 6

42 14

1475 985

75 27

8,4 6,8

1,7 1,4

3 2,3

91,5 89

0,89 0,89

255

250 SM

M2AA 250 SMB

06300-c-d

4 6

63 18,5

1475 985

110 40

7,5 7,3

2,4 3

2,7 2,6

93,5 87

0,89 0,79

335

280 SM

M2CA 280 SMA

07700-c-d

4 6

77 25

1486 991

144 54

7,6 7,7

2,4 3,2

2,9 2,7

93,9 89,3

0,83 0,76

490

280 M

M2CA 280 MB

09000-c-d

4 6

90 28

1485 991

161 58

7,4 7,7

2,3 3,2

2,7 2,8

94,2 89,8

0,86 0,78

550

315 SM

M2CA 315 SMA

11000-c-d

4 6

110 32

1489 992

199 67

6,6 6,5

1,9 2,8

2,6 2,9

95,2 91,2

0,85 0,78

730

315 M

M2CA 315 MB

12500-c-d

4 6

125 37

1488 992

219 75

6,6 6,4

1,9 2,9

2,4 2,8

95,5 92,2

0,86 0,79

850

315 L

M2CA 315 LA

15000-c-d

4 6

150 44

1488 991

260 88

6,6 6,4

1,9 3

2,4 2,7

95,7 92,6

0,87 0,79

970

Code suffix for voltage (c) 1) Correction factors Correction factors for current at other voltages: 230 V = 1.74 ; 500 V = 0.80 The speeds, efficiencies and power factors are applicable at 230, 400 and 500 V. l 2) st = Ratio of motor starting current to full-load current l

Fläkt Woods Oy

FIFLO 4249 GB 02.12

V (sizes 71–132) 1 = 220–230 230 V (sizes 160–250) V (sizes 112–132) 2 = 380–400 400 V (sizes 160–315)

Temperature sensors in the stator winding, code suffix (d)

V (sizes 71–100) 4 = 400–415 415 V (sizes 160–315)

0 = without 1 = with bimetal temperature contacts 2 = with thermistor

5 = 500 V

(sizes 71–315)

75

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Motor Data – Two-speed Motors, 50 Hz 4/8 poles = 1500/750 r/min One stator winding (Dahlander-connection) Size designation

IEC

ABB Motors

No. of Ordering code motor ARAL-4poles

71

M2VA 71 B

90037-c-d

80

M2VA 80 A

90055-c-d

80

M2VA 80 B

90075-c-d

90 S

M2AA 90 S

90110-c-d

90 L

M2AA 90 L

90170-c-d

100 L

M2AA 100 LA

90230-c-d

100 L

M2AA 100 LB

90280-c-d

112 M

M2AA 112 M

00350-c-d

132 S

M2AA 132 S

00500-c-d

132 M

M2AA 132 M

00680-c-d

160 M

M2AA 160 M

01050-c-d

160 L

M2AA 160 L

01550-c-d

180 M

M2AA 180 M

01700-c-d

180 L

M2AA 180 L

02200-c-d

200 ML

M2AA 200 MLA

02900-c-d

200 ML

M2AA 200 MLB

03300-c-d

225 SM

M2AA 225 SMB

04200-c-d

225 SM

M2AA 225 SMC

05000-c-d

250 SM

M2AA 250 SMB

06000-c-d

280 S

M2CA 280 SA

06500-c-d

280 SM

M2CA 280 SMA

08000-c-d

280 M

M2CA 280 MB

09000-c-d

315 SM

M2CA 315 SMA

11000-c-d

315 M

M2CA 315 MB

13200-c-d

315 L

M2CA 315 LA

16000-c-d

4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8

Rated output,

Speed,

kW

r/min

0,37 0,09 0,55 0,11 0,75 0,2 1,1 0,26 1,7 0,35 2,3 0,5 2,8 0,6 3,5 0,7 5 1 6,8 1,4 10,5 2,2 15,5 2,7 17 3,4 22 4,4 29 6,5 33 8 42 10 50 11 60 15 65 15 80 20 90 23 110 22 132 26 160 32

1360 700 1410 690 1410 690 1410 700 1390 700 1415 715 1430 720 1430 720 1450 725 1460 730 1460 735 1460 735 1470 730 1475 735 1470 730 1475 730 1480 740 1465 735 1475 735 1484 743 1486 743 1486 742 1487 744 1486 746 1486 743

1) Correction factors Correction factors for current at other voltages: 230 V = 1.74 ; 500 V = 0.80 The speeds, efficiencies and power factors are applicable at 230, 400 and 500 V. l 2) st = Ratio of motor starting current to full-load current l

At rated output Current at 400 V, ca A 1,1 0,48 1,7 0,6 2,1 1 2,8 1,2 4,0 1,6 5,2 1,9 6,4 2,2 7 2,5 9,9 3,3 13,7 5,1 21 7,4 30 9,5 33 11 43 15 54 17 61 21 85 27 91 28 104 34 121 38 150 50 164 56 197 56 235 65 283 80

FIFLO 4249 GB 02.12

lst 2) l 3,1 1,7 3,6 2,4 3,7 2,4 4,2 2,4 4,5 2,5 4,6 2,7 5,2 3 6,8 4,4 6,4 3,6 7,6 3,6 6,9 3,7 6,9 3,9 5,8 4,3 6,7 3,9 6,9 4,2 7,8 4,2 7,8 5 7,3 4,7 7,9 4,7 7,5 5,3 8,5 5,4 8,8 5,4 6,8 4,9 6,8 4,8 7 4,8

Mst M 1,3 1,8 1,9 1,6 2 1,6 1, 8 1,2 2,2 1,5 1,8 1,2 2 1,2 1,6 1,7 1,5 1 2 1,4 2,2 1,5 2,2 1,7 1,7 1,2 2 1,7 2,2 1,9 2,6 1,9 2,5 2,2 2,3 2 2,6 2,1 2,7 2,8 3,3 2,9 3,6 2,8 1,9 2,1 2 2 2,1 2,1

Mmax M 1,4 1,9 2 1,7 2,1 1,7 2,3 1,9 2,6 2,1 2,4 1,9 2,6 2,2 2,5 2,7 2,3 2 2,8 2,7 2,7 2,3 2,6 2,6 2,3 1,9 2,6 2,3 2,4 1,9 2,6 1,8 3 2,3 2,5 2 2,7 2 2,9 2,3 3,4 2,6 3,5 2,6 2,6 2,5 2,6 2,4 2,7 2,5

Efficiency, η%

Power factors, cos ϕ

Weight,

58 19 62 40 69 46 73 53 74 57 76 63 81 68 81 71 83 74 85 73 87,5 79 88,5 79,5 88,5 78 89,5 79 90,5 86 91,5 86,5 92 89,5 92,5 89,5 93 90 93,2 90 93,8 91,5 94,1 91,8 94,6 92,5 94,9 93 95,2 93,4

0,84 0,52 0,74 0,65 0,76 0,64 0,80 0,63 0,82 0,57 0,84 0,6 0,82 0,58 0,89 0,58 0,87 0,59 0,84 0,55 0,84 0,54 0,85 0,51 0,85 0,56 0,83 0,53 0,86 0,64 0,86 0,64 0,78 0,61 0,87 0,65 0,86 0,70 0,84 0,63 0,83 0,63 0,85 0,64 0,85 0,62 0,86 0,64 0,86 0,64

6,5

kg

9 10,5 13 16 20 23 32 48 59 94 117 137 161 180 205 265 265 335 445 490 550 730 850 970

Delkod för spänning (c) V (sizes 71–132) 1 = 220–230 230 V (sizes 160–250) V (sizes 112–132) 2 = 380–400 400 V (sizes 160–315)

Temperature sensors in the stator winding, code suffix (d)

V (sizes 71–100) 4 = 400–415 415 V (sizes 160–315)

0 = without 1 = with bimetal temperature contacts 2 = with thermistor

5 = 500 V

Fläkt Woods Oy

1)

76

(sizes 71–315)

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Accessories Plummer block with grease nipple GTLZ-06-3-ccc-d-0 Plummer block with grease nipple for the GTHB-3 (for size 040–071) GTLZ-09-3-ccc-d-0 Plummer block with grease nipple for the GTLB and GTLF (for sizes 025–071) d = 1 for right-hand version d = 2 for left-hand version The type GTLZ-06 and -09 Plummer block with grease nipple is mounted on a welded, compact frame with

bearing bracket. Single-row, deep-groove ball bearings designed to be secured to the shaft by means of a tapered adapter sleeve are used in GTLZ-06 and -09 plummer blocks. If the fan is supplied with a flat belt drive, it should be equipped with the GTLZ-06/09.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

77

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Accessories Flexible connections, inlet

Protective screen, inlet

GTLZ-11-3-ccc-1-0 Normal version, max. +80 °C

GTLZ-13-3-ccc-1-0

Protective screen

GTLZ-12-3-ccc-1-0 Smoke extraction version, max. +400 °C/2 hours

Fläkt Woods Oy

FIFLO 4249 GB 02.12

78

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Accessories Flexible connections, outlet

Protective screen, outlet

GTLZ-21-3-ccc-1-0 Normal version, max. +80 °C

GTLZ-23-3-ccc-1-0 Protective screen, outlet

GTLZ-22-3-ccc-1-0 Smoke extraction version, max. +400 °C/2 hours

Counterflange, outlet

Dimension sketch

GTLZ-24-3-ccc-1-0 Counterflange

B out Z

X

A out

A2 A1 A in

YxW

L

B in B1 B2

Size

A in

A out

A1

A2

B in

B out

B1

B2

Z

X

Y

W

n

D

L

025 031 040 045 050 056 063 071 080 090 100 112 125 140

322 404 507 569 638 715 801 898 1015 1138 1267 1120 1250 1400

382 465 567 629 698 775 861 958 1095 1218 1367 1220 1350 1500

352 434 537 599 668 745 831 928 1056 1175 -

362 444 546 530 677 754 840 937 1065 1185 1320 1180 1310 1460

179 217 269 299 334 375 417 466 533 595 670 710 800 /900

239 277 329 359 394 435 477 526 613 675 770 810 900 1000

209 247 299 329 364 405 447 496 573 632 -

219 257 308 338 373 414 456 505 583 642 723 770 860 960

– – 149,5 164,5 182,0 109,3 119,6 132,0 212,0 236,0 227,0 150 150 150

– – – – – 186,3 207,8 232,0 153,0 165,0 270,0 300,0 450,0 450,0

2 2 4 4 4 4 4 4 5 5 6 7 8 9

176,0 217,0 134,3 149,8 167,0 186,3 207,8 232,0 212,0 236,0 220,0 150,0 150,0 150,0

6 6 12 12 12 14 14 14 16 16 18 20 24 24

10 10 10 10 10 10 10 10 10 10 10 15 15 15

115 115 115 150 150 150 150 150 145 145 150 150 150 150

Fläkt Woods Oy

FIFLO 4249 GB 02.12

79

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Accessories Inspection cover

Anti-vibration mountings

GTLZ-32-3-ccc-d-0 Inspection cover Mounted on the back plate of the fan. Made of galvanised sheet steel. d = location on fan casing, 0 – 4, see illustration

GTLZ-42-3-ccc-d-0 Anti-vibration mountings, rubber GT-3-025–071 d = 1 GTLB and GTLF ( 4 pc.) d = 2 GTHB (4 pc.) GT-3-080–100 d = 1 with motor IEC 100–132 (4 pc.) d = 2 with motor IEC 160–225 (6 pc.)

0 1

GT-3-112–140 d = 1 ( 6 pc.)

2

3 4

Drain GTLZ-34-3-ccc-d-0 Drain Mounted on the back plate of the fan. Made of galvanised sheet steel. d = location on fan casing, 0 – 4, see illustration 0 1

2

3 4

Note! The position of the inspection cover and drain depends on the discharge direction. Recommended positions are: GT…-3-bbb-c-d1-00 (0°)

GTLZ-32-3-ccc-4-0 GTLZ-34-3-ccc-2-0

GT…-3-bbb-c-d3-00 (90°)

GTLZ-32-3-ccc-1-0 GTLZ-34-3-ccc-4-0

GT…-3-bbb-c-d7-00 (270°)

GTLZ-32-3-ccc-3-0 GTLZ-34-3-ccc-0-0

Fläkt Woods Oy

FIFLO 4249 GB 02.12

80

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Accessories Flow Measurement Device

Flow Measurement Device with manometer

GTLZ-50-3-ccc-1-0

Flow measurement device for the GTLF

GTLZ-53-3-ccc-1-0

Flow measurement device with manometer for the GTLF

GTLZ-51-3-ccc-1-0

Flow measurement device for the GTLB, (not for sizes 112–140)

GTLZ-54-3-ccc-1-0

Flow measurement device with manometer for the GTLB, (not for sizes 112–140)

GTLZ-52-3-ccc-1-0

Flow measurement device for the GTHB

GTLZ-55-3-ccc-1-0

Flow measurement device with manometer for the GTHB

GTLZ-50, 51, 52 Flow measurement devices The flow measurement device is used for measuring the air flow in type GT fans. This is done by measuring the differential pressure in the device. The flow measurement device should be mounted in the fan inlet. The air flow is calculated as a function of coefficient k and the differential pressure reading ∆pm in the following manner:

1 q=— x k där q ∆pm k

GTLZ-53, 54, 55 Flow measurement devices The flow measurement device is supplied with a manometer as well. The supply includes flow measuring device, manometer with scale and mounting bracket for the measuring device and hoses. For a technical specification, see the GTLZ-50, 51, 52 on the preceding page.

pm

3

= air flow (m /s) = differential pressure reading (Pa) = coefficient unique to the fan selected

The air flow that corresponds to the differential pressure reading can most easily be read with a manometer whose scale is graduated in accordance with the function above for a specific fan. On request, detailed charts can be supplied. The accuracy of the readings is ±10 %. If the flow measurement device is recalibrated at the site (for instance in an air handling unit), an accuracy of ±5 % can be achieved.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

81

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Accessories Painted finish GTLZ-60-3-ccc-d-0

Painted finish, inner and outer surfaces d = 1 Epoxy powder coated and baked. 60 µm, colour: AM 8043, dark grey, M2 d = 2 Epoxy powder coated and baked. 100 µm, colour: AM 8043, dark grey, M3 d = 3 Wet-painted finish in three layers. 250 µm, colour: SSG28, light grey

d =1 60 µm thick painted finish The fan casing, impeller and bearing bracket as well as accessories are coated with 60 mm thick epoxy powder and baked. The colour is AM 8043, dark grey. All bolts and nuts must be made of stainless steel. Painting process: – Alkali degreasing – Iron phosphate pre-treatment – Flushing with +40 °C water – Drying at 150 °C – Powder painting, 60 µm coat in one layer – Drying at 215 °C

Motor cover GTLZ-77-3-ccc-d-0

Motor cover, made of galvanised steel. d = motor size (IEC) For fan sizes 025–071 1 = 071–100 2 = 112–132 3 = 160–180

Epoxy powder is well suited for coating objects that are subject to mechanical and chemical stress. It is an excellent rust-inhibitor and can withstand acids, alkaline solutions, greases and solvents.

For fan sizes 080–140 4 = 100–160 5 = 180–250

d =2 100 µm thick painted finish; meets the provisions for Environmental Class M3. The fan casing, impeller and bearing bracket as well as accessories are coated with 100 µm thick epoxy powder and baked. The colour is AM 8043, dark grey. All bolts and nuts must be made of stainless steel. The coating process and epoxy powder are the same as in version d = 1; the coat is 100 µm thick in one layer. d = 3 250 µm wet painted finish in three coats. The fan casing and bearing bracket as well as accessories are painted with 250 µm thick epoxy in 3 layers. The colour is SSG28, light grey. The impeller is coated with 100 µm thick epoxy powder and baked. The colour is AM 8043, dark grey. All bolts and nuts must be made of stainless steel.

Fläkt Woods Oy

FIFLO 4249 GB 02.12

82

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Ordering Codes Centrifugal fan

GTLB-a-bbb-c-dd-ee GTHB-a-bbb-c-dd-ee GTLF -a-bbb-c-dd-ee

Plummer block with grease nipple GTLZ-06-3-ccc-d-0 for GTHB (for sizes 040–071)

LB = centrifugal fan with backward curved blades (Sizes 025–140) HB =centrifugal fan with backward curved blades (Sizes 040–100) LF = centrifugal fan with forward curved blades (Sizes 025–071)

Fan size (ccc)

Fan type (a) 3 = single-inlet fan for a belt drive

Plummer block with grease nipple GTLZ-09-3-ccc-d-0 for GTLB and GTLF (for sizes 025–071)

Delivery version (d) 1 for right-hand version 2 for left-hand version

Size (bbb) 025, 031,040, 045, 050, 056, 063, 071, 080, 090, 100, 112, 125, 140

Fan size (ccc)

Version (c) 1 = normal version 6 = smoke extraction version (only GTLB and GTLF) 8 = spark-proof version

Delivery version (d) 1 for right-hand version 2 for left-hand version

Version and direction of discharge (dd) First d: 1 = right-hand version 2 = left-hand version

Flexible connection, inlet Normal version, max. +80 °C

Second d: 1 = 0º 3 = 90º 7 = 270º Motor location and generation (ee) First e: 0 = motor behind fan First e: 1 = motor alongside the fan (sizes 112-140) Second e: 0 = first generation Belt drive for GTLF-3 GTRF-3-bbb-1-dddd Belt drive for GTLB/GTHB-3 GTRB-3-bbb-1-dddd

Fan size (ccc) Flexible connection, inlet Smoke extraction version, max. +400 °C

Protective screen, inlet

Fan speed, r/min (dddd) (If a two-speed motor is used, specify the higher speed.) APAL-a-bbbbb-c-d ARAL-a-bbbbb-c-d ATAL-a-bbbbb-c-d

Flexible connection, outlet Normal version, max. +80 °C

GTLZ-21-3-ccc-1-0

Fan size (ccc) Flexible connection, outlet Smoke extraction version, max. +400 °C

Note: Due to generation change of motors the first digit “b” is 9 instead of 0 in motor sizes IEC 071–100. Accessories GTLZ-aa-b-ccc-d-e (aa) Type of accessory (b) 3 = Accessory for the GT..-3 (ccc) Fan size (d) 1 = to be supplied with fan (specify d = 0 if you are placing an order for individual accessories only). See the ordering code as well. (e) Generation digit. FIFLO 4249 GB 02.12

GTLZ-13-3-ccc-1-0

Fan size (ccc)

See tabels on pages 70–76 Select the number of motor poles as follows: Fan speed < 459 r/min = 6-pole motor Fan speed 460-2344 r/min = 4-pole motor Fan speed > 2345 r/min = 2-pole motor

Fläkt Woods Oy

GTLZ-12-3-ccc-1-0

Fan size (ccc)

Fan size (bbb)

Motor

GTLZ-11-3-ccc-1-0

GTLZ-22-3-ccc-1-0

Fan size (ccc) Protective screen, outlet

GTLZ-23-3-ccc-1-0

Fan size (ccc)

83

Specifications are subject to alteration without notice

Centrimaster GT-3

CATALOGUE

Ordering Codes Accessories Counterflange, outlet

Accessories Anti-vibration mountings

GTLZ-24-3-ccc-1-0

Fan size (ccc)

Fan size (ccc)

Inspection cover

Version (d) 1 = for GTLB and GTLF 2 = for GTHB

GTLZ-32-3-ccc-d-0

Fan size (ccc)

GTLZ-42-3-ccc-d-0

Flow measurement device for GTLF

Location, se illustration (d) d= 0 1 2 3 1 4

GTLZ-50-3-ccc-1-0

Fan size (ccc) 0

Flow measurement device for GTLB (not for sizes 112–140)

GTLZ-51-3-ccc-1-0

Fan size (ccc)

2

Flow measurement device for GTHB

3 4

GTLZ-52-3-ccc-1-0

Fan size (ccc)

Drain

Flow measurement device with manometer GTLF

GTLZ-34-3-ccc-d-0

GTLZ-53-3-ccc-1-0

Fan size (ccc)

Fan size (ccc) Location, se illustration (d) d= 0 1 2 3 1 4

0

2

Flow measurement device with manometer GTLB (not for sizes 112–140) Fan size (ccc)

GTLZ-54-3-ccc-1-0

Flow measurement device with manometer GTHB

GTLZ-55-3-ccc-1-0

Fan size (ccc) Painted finish, inner and outer surfaces

3 4

GTLZ-60-3-ccc-d-0

Fan size (ccc) Version (d) 1 = painted finish, 60 µm 2 = painted finish, 100 µm 3 = wet-painted finish, 250 µm in three layers Motor cover

Fläkt Woods Oy

FIFLO 4249 GB 02.12

84

GTLZ-77-3-ccc-d-0

Specifications are subject to alteration without notice

Fläkt Woods Oy, Kalevantie 39, FI-205 20 Turku, Finland

FIFLO 4249A GB 02.12

teleskop reklambyrå 036-30 83 80

t +358-102 230 000

f +358-102 233 475 w www.flaktwoods.com

View more...

Comments

Copyright ©2017 KUPDF Inc.
SUPPORT KUPDF