FSMF-Site Engineering-v1.pdf

January 9, 2020 | Author: Anonymous | Category: Electrical Connector, Cable, Fuse (Electrical), Telecommunications, Equipment
Share Embed Donate


Short Description

Download FSMF-Site Engineering-v1.pdf...

Description

FSMF module and FPFD optional module Site Engineering/ 25.01.2014 ©2013 Nokia Solutions and Networks. All rights reserved.

Contents of delivery of Flexi Multiradio 10 modules (1/3)

2

25-Jan-14

©2013 Nokia Solutions and Networks. All rights reserved.

Contents of delivery of Flexi Multiradio 10 modules (2/3)

3

25-Jan-14

©2013 Nokia Solutions and Networks. All rights reserved.

Contents of delivery of Flexi Multiradio 10 modules (3/3)

4

25-Jan-14

©2013 Nokia Solutions and Networks. All rights reserved.

FSMF plug in modules Optional, one integrated DC power distribution (FPFD)

Without covers for cabinet and rack installation

Optional, one transport sub-module

Optional baseband capacity and technology extension sub-module (0-2 pieces) With covers for stack, wall and pole installation

5

25-Jan-14

©2013 Nokia Solutions and Networks. All rights reserved.

FSMF External connectors External Connectors DC-Out 4x 16mm²

DC-out DC-in LMP PwrProfile 2x 16mm² RJ45

EIF2/RF/6 SFP+

RF/EXT1..3 3x SFP+

sRIO SFP+

DC-out DC-in PwrProfile PwrProfile

BB EXT1 BB EXT2 EIF1 QSFP QSFP RJ45

sRIO SFP+

EAC Sync In Sync Out HDMI HDMI HDMI

BB EXT RF/EXT QSFP SFP+

•EAC: 6 Alarm signals and 6 signals that are SW assignable for either Alarm or Control signals CAN bus interface . HDMI is the connector type used for the EAC interface •FSMF has a 48V input screw terminal connector on the front panel for power input of its own, if FPFD is not used. 6

25-Jan-14

©2013 Nokia Solutions and Networks. All rights reserved.

Power connection to FSMF (when optional FPFD is not used) Installation of FSMF front panel DC interface port (without optional FPFD PDU installed) requires a dedicated fuse. The fuse size should be between 20 A and 30 A.

7

25-Jan-14

©2013 Nokia Solutions and Networks. All rights reserved.

Integrated optional (FPFD) module Flexi Power Distribution Sub-Module (FPFD) is a highly integrated optional size-optimized power distribution unit (PDU) for System Module variant FSMF. It is installed in the top left slot of the System Module. FPFD provides four external -48 V DC outputs (fixed to 1100 W) for Flexi Modules (RF Module, RRH, or external System Module) or any standard 48 V DC device at the site, and one internal DC output to System Module itself via internal connector (MEC8).

FPFD has integrated basic Over Voltage Protection (OVP Type approval level with 2kV/1kV), EMC filtering and reverse polarity protection. It is IP65 rated. Flexi Power Distribution Sub-Module (FPFD) can be used for stacked and feederless configurations in the same way as earlier integrated Flexi PDUs.

8

25-Jan-14

©2013 Nokia Solutions and Networks. All rights reserved.

FPFD interfaces The FPFD provides the following external interfaces: One -48 V DC input (4-25 mm2/4 AWG) Four external -48 V DC outputs (4-16 mm2/6 AWG screw terminals) One internal DC output to the System Module ON/OFF switches & status LEDs at the control panel

The control panel is located on the front panel of the Flexi Multiradio 10 BTS Power Distribution Sub-Module (FPFD). There are five LEDs for the corresponding output ports, and two push buttons for the ON/OFF functionality of the outputs.

9

25-Jan-14

©2013 Nokia Solutions and Networks. All rights reserved.

Power connection to FPFD (FSMF powered via FPFD) When FPFD is in use, it feeds the FSMF core DC in port internally. In this case make sure that the FSMF front panel DC interface port is covered with IP seal and not used. The fuse size should be between 100 A and 125A if all 4 ports will be connected to 1100W .

10

25-Jan-14

©2013 Nokia Solutions and Networks. All rights reserved.

Routing the FPFD power input cable The two FPFD DC input cables can be routed between FPFD and dummy unit or transmission card. If there is no space for both cables, one of them can be routed at the right side of FTIF card.

11

25-Jan-14

©2013 Nokia Solutions and Networks. All rights reserved.

DC cable requirements for 80 W RF Modules The DC cable is not included in the 80 W RF Module delivery. 48 VDC power can be fed from a System Module or directly from an external power source If FXEB/FRGT is used with FSMC/D/E or FPFC/FPFD (30A PDU), then the rules of below table should apply. 472806A:FPCA DC cable 2xmultibeam cut off-open 2 m (dual cable) Only if low voltage in RFM DC input

3x80w RFM SM rel3+FPFD

3x80w RFM SM rel3+FPFD

12

25-Jan-14

Standard DC cable open-open (single cable) for outdoor use ©2013 Nokia Solutions and Networks. All rights reserved.

FPMA AC wiring and fuse requirements The recommended wire cross section and fuse size for FPMA is listed below

13

25-Jan-14

©2013 Nokia Solutions and Networks. All rights reserved.

EAC cable(FTSI 472578A) wiring

14

25-Jan-14

©2013 Nokia Solutions and Networks. All rights reserved.

Thank you