FlexiPacket MultiRadio Rel. 2.5 FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Issu Issue: e: 1
Iss Issue date ate: Ma May 201 2012
A25000-A1600-C040-01-76P1
Nokia Siemens Networks is continually str iving to reduce the adverse environmental effects of its products and services. We would like to encourage you as our customers and users t o join us in working towards a cleaner, safer environment. Please recycle product packaging and follow the recommendations for power use and proper disposal of our products and their components. If you should have questions regarding our Environmental P olicy or any of the environmental services we offer, please contact us at Nokia Siemens Networks for any additional information.
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
The information in this document i s subject to change without notice and descri bes only the product defined in the introduction of this documentation. This documentation is in tended for the use of Nokia Siemens Networks c ustomers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by pr ofessional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the pr ocess of continuous development and improvement of the documentation. The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or so ftware products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However , Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of m aterial errors and omissions. N okia Siemens Networks will, if deemed necessary by Nokia Siemens Networks , explain issues which may not be covered by the document. Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT. This documentation and the product it desc ribes are considered protected by copyrights and other intellectual property rights according to the applicable laws. The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG. Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only. Copyright © Nokia Siemens Networks 2012. All rights reserved.
f
Important Notice on Product Safety This product may present safety risks due to laser, electricity, heat, and other sources of danger. Only trained and qualified personnel may i nstall, operate, maintain or otherwise handle this product and only after having carefully read the safety information applicable to this product. The safety information is pr ovided in the Safety Information section in the “ Legal, Safety and Environmental Information” part of this document or documentation set.
The same text in German:
f
Wichtiger Hinweis zur Produktsicherheit Produktsicherheit Von diesem Produkt können Gefahren durch Laser, Elektrizität, Hitzeentwicklung oder andere Gefahrenquellen ausgehen. Installation, Betrieb, Wartung und sonstige Handhabung des Pr oduktes darf nur durch geschultes und qualifiziertes Personal unter Be achtung der anwendbaren Sicherheitsanforderungen erfolgen. Die Sicherheitsanforderungen finden Sie unter „Sicherheitshinweise“ im Teil „Legal, Safety and Environmental Information“ dieses Dokuments oder dieses Dokumentationssatzes.
2
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
The information in this document i s subject to change without notice and descri bes only the product defined in the introduction of this documentation. This documentation is in tended for the use of Nokia Siemens Networks c ustomers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by pr ofessional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the pr ocess of continuous development and improvement of the documentation. The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or so ftware products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However , Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of m aterial errors and omissions. N okia Siemens Networks will, if deemed necessary by Nokia Siemens Networks , explain issues which may not be covered by the document. Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT. This documentation and the product it desc ribes are considered protected by copyrights and other intellectual property rights according to the applicable laws. The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG. Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only. Copyright © Nokia Siemens Networks 2012. All rights reserved.
f
Important Notice on Product Safety This product may present safety risks due to laser, electricity, heat, and other sources of danger. Only trained and qualified personnel may i nstall, operate, maintain or otherwise handle this product and only after having carefully read the safety information applicable to this product. The safety information is pr ovided in the Safety Information section in the “ Legal, Safety and Environmental Information” part of this document or documentation set.
The same text in German:
f
Wichtiger Hinweis zur Produktsicherheit Produktsicherheit Von diesem Produkt können Gefahren durch Laser, Elektrizität, Hitzeentwicklung oder andere Gefahrenquellen ausgehen. Installation, Betrieb, Wartung und sonstige Handhabung des Pr oduktes darf nur durch geschultes und qualifiziertes Personal unter Be achtung der anwendbaren Sicherheitsanforderungen erfolgen. Die Sicherheitsanforderungen finden Sie unter „Sicherheitshinweise“ im Teil „Legal, Safety and Environmental Information“ dieses Dokuments oder dieses Dokumentationssatzes.
2
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Table of Contents This document has 61 pages. 1 1.1 1. 1
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Inte ten nded aud udiience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.2 1.2 1.3 1. 3 1.4 1. 4
Str truc ucttur ure e of thi his s doc docum umen ent. t. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Symb mbo ols and co conventi tio ons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Histor ory y of of ch change ges. s. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.5 1.5 1.6 1. 6 1.7 1. 7
Waste ele lect ctrrica call an and ele elec ctronic equip ipme men nt (W (WEE EEE E) . . . . . . . . . . . . . . . . 9 RoHS comp mpllia ian nce . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Saf afe ety in instru ruct ctiions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.7.1 1.7. 1 1.7. 1. 7.2 2 1.7. 1. 7.3 3
RF En Ener ergy gy He Heal alth th Ha Haza zard rd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Prot Pr otec ecti tion on ag agai ains nstt Lig Light htni ning ng . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Prot Pr otec ecti tion on fr from om RF Bu Burn rns s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.7. 1. 7.4 4
Warn Wa rnin ing g – Tur Turn n off off al alll po powe werr be befo fore re se serv rvic icin ing g . . . . . . . . . . . . . . . . . . . . 11
2 2.1 2. 1
FlexiPac ack ket Microwave scenarios . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Ove verv rviiew . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.2 2.2 2.3 2. 3 2.4 2. 4
Pro roce cedu durre ov ove ervi view. ew. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 PC re req quir ire emen entts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Comm Co mmis issi sion onin ing g pr proc oced edur ures es for the Sy Syst stem em Ty Type pes s al alre read ady y av avai aila labl ble e wi with FlexiPacket MultiRadio SVR 2.4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.5 2.5 2.5. 2. 5.1 1 2.5. 2. 5.2 2
Comm mmis issi sion oniing procedure for for 2+2 XP XPIIC . . . . . . . . . . . . . . . . . . . . . . . . 14 IDU ID U con confi figu gura rati tion. on. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 IDUID U-OD ODU U co conf nfig igur urat atio ion n . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
2.5.3 2.5. 3 2.6 2. 6 2.6 2. 6.1
Exampl Exam ple: e: EE-LA LAN N fo forr Et Ethe hern rnet et tr traf affi fic c wit with h VI VID D 10 1000 00 . . . . . . . . . . . . . . . . 50 Comm mmis issi sion oniing pro roce ced dure for for 2+0 XP XPIIC Ri Ring. . . . . . . . . . . . . . . . . . . . 56 How to co conf nfiigu gure re the Ring Hea ead d NE NE . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
2.6 2. 6.2
How to co conf nfiigu gure re the Ring Nod ode e NE NE . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
3
Acronyms and abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
3
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
List of Figures
4
Figure 1
WEEE label. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Figure 2 Figure 3 Figure 4
Station block diagram (Example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Single IDU solution (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Two IDUs solution (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Figure 5 Figure 6 Figure 7
Acting Master (Radio) Sync Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Acting Slave (Radio) Sync Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Acting Master (GbE) Sync Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Figure 8
Acting Slave (GbE) Sync Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
List of Tables Table 1
Structure of this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Table 2 Table 3 Table 4
List of symbols and conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 History of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Supported IDUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Table 5
System Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
5
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
6
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Preface
1 Preface This document provides a guideline for placing into service a FlexiPacket MultiRadio link.
1.1
Intended audience This document is intended to the commissioning technicians in charge to commission a FlexiPacket MultiRadio link (IDU+ODU).
1.2
Structure of this document The document is divided into the following main chapters: Chapter
Subject
Chapter 1
Preface
Provides an introduction to the document and the safety instructions
Chapter 2
FlexiPacket Microwave scenarios
Provides the procedure to line-up and commission the FlexiPacket MultiRadio connected to a Nokia Siemens Networks Hub
Chapter 3
Acronyms and abbreviations
Lists the acronyms and abbreviations used in this document
Table 1
1.3
Title
Structure of this document
Symbols and conventions The following symbols and mark-up conventions are used in this document: Representation
f DANGER! f WARNING! f CAUTION!
Meaning
A safety message indicates a dangerous situation where personal injury is possible. The keywords denote hazard levels with the following meaning: DANGER! - Indicates a hazardous situation which, if not avoided, will result in death or serious (irreversible) personal injury. WARNING! - Indicates a hazardous situation which, if not avoided, could result in death or serious (irreversible) personal injury. CAUTION! - Indicates a hazardous situation which, if not avoided, may result in minor or moderate (reversible) personal injury.
w NOTICE: Table 2
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
A property damage message indicates a hazard that may result in equipment damage, data loss, traffic interruption, and so on.
List of symbols and conventions
7
Preface
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Representation
Meaning
g
A note provides important information related to the topic, for example, not obvious exceptions to a rule or side effects.
t
A tip provides additional information related to the topic which is not essential in the context, but given for convenience.
Bold
•
•
•
Italic
•
•
typewriter
•
All names of graphical user interface (GUI) objects, such as windows, field names, buttons, and so on. Example: Select the Full Screen check box and press OK . Terms and abbreviations which are linked to an entry in the glossary and list of abbreviations respectively. Important key words. Files, folders, and file system paths. Example: /usr/etc/sbin/ftpd.exe Emphasized words. Input to be typed in a command line or a GUI field. Examples: ping -t 192.168.0.1
Enter World in the Domain field. •
•
Output from a command, error messages, content of a status line, and so on. File content, such as program sources, scripts, logs, and s ettings.
Placeholders, for example as part of a file name or field value. Examples: .png or :
[square brackets]
A key to be pressed on a PC keyboard, for example [F11]. Keys to be pressed simultaneously are concatenated with a “+” sign, for example [CTRL]+[ALT]+[DEL]. Keys to be pressed one after another are concatenated with spaces, for example [ESC] [SPACE] [M].
>
The greater than symbol “>” is used to concatenate a series of GUI items in order to depict a GUI path. This is an abridged presentation of a procedure to be carried out in order to perform an action or display a window or dialog box. Examples: A simple menu path: File > Save as ... A more complex GUI path: > Nokia Siemens Networks TransNet window > File menu > Change Password command > Change Password dialog box
Table 2
8
List of symbols and conventions (Cont.)
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Preface
Representation
x (in card names)
Meaning
For convenience, card names are sometimes listed with a lower case x variable, in order to concisely represent multiple cards. Example: I01T40G-x (is to be interpreted as I01T40G-1 and I01T40G-2)
Table 2
List of symbols and conventions (Cont.)
Screenshots of the graphical user interface are examples only to illustrate principles. This especially applies to a software version number visible in a screenshot.
1.4
History of changes Issue
1
Table 3
1.5
Issue date
May 2012
Remarks
1st version
History of changes
Waste electrical and electronic equipment (WEEE) All waste electrical and electronic products must be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities. The WEEE label (see Figure 1) is applied to all such devices.
Figure 1
WEEE label
The correct disposal and separate collection of waste equipment will help prevent potential negative consequences for the environment and human health. It is a precondition for reuse and recycling of used electrical and electronic equipment. For more detailed information about disposal of such equipment, please contact Nokia Siemens Networks. The above statements are fully valid only for equipment installed in the countries of the European Union and is covered by the directive 2002/96/EC. Countries outside the European Union may have other regulations regarding the disposal of electrical and electronic equipment.
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
9
Preface
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
1.6
RoHS compliance FlexiPacket MultiRadio complies with the European Union RoHS Directive 2002/95/EC on the restriction of use of certain hazardous substances in electrical and electronic equipment. The directive applies to the use of le ad, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB), and polybrominated diphenylethers (PBDE) in electrical and electronic equipment put on the market after 1 July 2006. Materials usage information on Nokia Siemens Networks Electronic Information Products imported or sold in the People’s Republic of China
FlexiPacket MultiRadio complies with the Chinese standard SJ/T 11364-2006 on the restriction of the use of certain hazardo us substances in electrical and electronic equipment. The standard applies to the use of lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB), and polybrominated diph enyl ethers (PBDE) in electrical and electronic equipment put on the market after 1 March 2007.
1.7
Safety instructions In this paragraph are indicated all the safety rules and the precautionary measures to follow while carrying out operations on the equipment in order to prevent injuries to personnel and/or damages to the equipment components.
t 1.7.1
PLEASE READ THESE SAFETY PRECAUTIONS!
RF Energy Health Hazard
This symbol indicates a risk of personal injury due to radio frequency exposure. The radio equipment described in this guide uses radio frequency transmitters. No one shall be allowed to come in the close proximity of the antenna's front while the transmitter is operating. The antenn a will be professionally installed on the outdoor permanent fix-mounted structures in order to keep it separate from any other antenna and from everybody else.
f
WARNING!
RF Energy Exposure Limits and Applicable Rules for 6-38 GHz. It is recommended that for each radio equipment deployment site th e radio equipment operator refers to the RF exposure rules and precaution for each frequency band and to all ot her applicable rules and precautions with respect to transmitters, facilities, and operations that may affect the environment due to the RF emissions.
10
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Preface
Appropriate warning signs must be properly placed and affixed at the equipment site and access entries.
1.7.2
Protection against Lightning
Article 810 of the US National Electric Department of Energy Handbook 1996 specifies that radio and television lead-in cables must have adequate surge prot ection at or near the point of entry to the building. The code specifies that any shielded cable from an external antenna must have the shield directly connected to a 10 AWG wire that connects to the building ground electrode. Do not turn on power before reading product do cumentation. This device has a -48 VDC direct current input.
1.7.3
Protection from RF Burns It is dangerous to stare into or stand in front of an active antenna aperture. Do not stand in front of or look into an antenna without first ensuring that the associated transmitter or transmitters are switched off. Do not stare into the waveguide port of a n ODU (if applicable) when the radio is active.
1.7.4
f
Warning – Turn off all power before servicing WARNING!
Turn off all power before servicing.
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
11
FlexiPacket Microwave scenarios
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
2 FlexiPacket Microwave scenarios 2.1
Overview This document describes the sequence of steps to be adopted in order to install a site with Hub+FPMR(P) SVR 2.5 Network Elements. The supported Hubs are listed in Table 4 and are already supported by t he Commissioning Tool CT1.3SU2. Supported IDUs
Abbreviations
FlexiPacket Hub A1200 R5.0 (drop1, 2, 3)
A1200 or FPH1200
FlexiPacket Hub A2200 R4.5, R4.5 EP1,R5.0
A2200 or FPH2200
FlexiPacket FirstMile 200 R1.0 EP1
FirstMile 200 or FPFM200
FlexiPacket FirstMile 200 R2.0
FirstMile 200 or FPFM200
FlexiPacket Hub 800 R2.0
Hub 800 or FPH800
Table 4
Supported IDUs
In case of the usage of NON-NSN IDUs, the ODUs must be configured connecting directly the management PC, either via CT o r (in this case better) with the WebLCT just to avoid to use two different tools. In these scenarios the powering of the ODUs should be already in place without the P+E support. With the FPMR(P) SVR 2.5 the System Types in Table 5 are available: No.
Available in SVR
1
1+0/1+0 Ring
2.4
2
1+1 Hot Stand-by - two cables
2.4
3
1+1 Hot Stand-by - single cable
2.4
4
1+1 FD - two cables
2.4
5
1+1 SD - two cables
2.4
6
2+0 FD - two cables
2.4
7
2+0 XPIC - two cables
2.4
8
2+0 XPIC - single cable
2.4
9
2+2 XPIC - two cables
2.5
10
2+0 XPIC Ring - two cables
2.5
Table 5
12
System Type
System Types
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
2.2
FlexiPacket Microwave scenarios
Procedure overview Here below are listed the “main” steps to configure for the first time a link made up of FlexiPacket MultiRadio and Nokia Siemens Networks Hub. Steps
Build the site as in the final set-up (Hub+ODUs and related cabling). The NE should be powered as in the final set-up (P+E, Power Injector or Direct Power). Connect the CT PC to the reserved DCN Port of the Hub. If the system type to be configured is: •
•
•
a system type already available with t he SVR 2.4 (from 1 to 8 in Table 5) follow the procedure in paragraph 2.4 on page 13; a 2+2 XPIC system type (available only in SVR 2. 5) follow the procedure in paragraph 2.5 on page 14; a 2+0 XPIC Ring system type (available only in SVR 2.5) follow the procedure in paragraph 2.6 on page 56.
t
The ODU software can be 2.5 or 2.4 or 2.1 (in the last two cases the ODU can be upgraded also in field).
2.3
PC requirements Refer to paragraph 2.2 of FlexiPacket Commissioning Tool, Rel. 1.3SU2, Operating Documentation, Issue 1 - A25000-A1400-D000-01-76P1.
2.4
Commissioning procedures for the System Types already available with FlexiPacket MultiRadio SVR 2.4 Steps
Follow the procedure explained in document FlexiPacket Commissioning Tool, Rel. 1.3SU2, Operating Documentation, Issue 1 - A25000-A1400-D000-01-76P1. At the end of the operations in Step 1 open the ODU WebLCT and upgrade the ODU SW from SVR 2.4 to SVR 2.5.
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
13
FlexiPacket Microwave scenarios
2.5
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Commissioning procedure for 2+2 XPIC This paragraph gives the procedures to install for the first time (starting from scratch) the FlexiPacket Hub 800 and the FlexiPacket MultiRadio to commission the radio link. The initial ODU SVR is 2.1. The Commissioning Tool configures the ODUs with svr 2.4 and system type 2+0 XPIC. Figure 2 shows an example of the configuration with all the parameters to b e configured.
Figure 2
Station block diagram (Example)
Follow the steps here below and the steps in paragraphs 2.5.1 on page 16 and 2.5.2 on page 40. Steps
Connect the Ethernet cable from your computer Et hernet port to the OBB connector of the FlexiPacket Hub 800. OOB IP address is 192.168.254.100 Upgrade the FlexiPacket Hub 800 to R 2.0. Connect the Ethernet cable from your computer Ethernet port to the DCN connector of the FlexiPacket Hub 800 (DCN default IP address: 192.168.255.100). Run the FlexiPacket Commissioning Tool application from Start > Programs > Nokia Siemens Networks > Commissioning Tool > Run CT .
14
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
FlexiPacket Microwave scenarios
Select FPH800 .
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
15
FlexiPacket Microwave scenarios
2.5.1
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
IDU configuration
Steps
Click Next.
16
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
FlexiPacket Microwave scenarios
Click Next (Add Row if you have License key).
Configure and click Next.
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
17
FlexiPacket Microwave scenarios
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Configure and click Add . ODU type must be 2xFPMR(P). Power supply must be Enable. PWR source must be PWR on integrate device.
Configure and click Add . ODU type must be 2xFPMR(P). Power supply must be Enable.
18
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
FlexiPacket Microwave scenarios
PWR source must be PWR on integrate device.
Check and click Next.
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
19
FlexiPacket Microwave scenarios
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Add if you want another Management Port and click Next.
Configure and click Add . ODU type must be 2xFPMR(P). ODU system type must be 2+0 XPIC 1 Cable .
20
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
FlexiPacket Microwave scenarios
Configure and click Add . ODU type must be 2xFPMR(P). ODU system type must be 2+0 XPIC 1 Cable .
Check and click Next.
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
21
FlexiPacket Microwave scenarios
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Browse and select FPMR 2.4 software file for both row to upgrade from SVR 2.1 to SVR 2.4. Click Modify .
Fill Licence key and click Add .
22
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
FlexiPacket Microwave scenarios
Fill Licence key and click Add .
Click Next.
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
23
FlexiPacket Microwave scenarios
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Configure and click Modify .
Configure and click Modify . Click Next.
24
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
FlexiPacket Microwave scenarios
Configure and click Modify .
Configure and click Modify . Click Next.
Configure and click Modify .
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
25
FlexiPacket Microwave scenarios
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Set Source SyncE transfer: NCT (if no clock transfer).
Configure and click Modify . Set Source SyncE transfer: NCT (if no clock transfer).
26
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
t
FlexiPacket Microwave scenarios
Set Source SyncE setting “ Radio ” for remote 4 ODUs, if Source SyncE transfer Fixed and Source SyncE setting “ Ethernet” in the local ODU.
Modify if necessary and click Next.
Configure and click Modify .
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
27
FlexiPacket Microwave scenarios
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Radio port service status must be down .
Configure and click Modify . Radio port service status must be down . Click Next.
28
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
FlexiPacket Microwave scenarios
Modify if necessary and click Next.
Click on Save As. Click Next.
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
29
FlexiPacket Microwave scenarios
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Select Use default IP .
Click Next.
30
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
FlexiPacket Microwave scenarios
Click Yes.
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
31
FlexiPacket Microwave scenarios
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Click OK .
Click Yes .
32
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
FlexiPacket Microwave scenarios
Click Validate.
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
33
FlexiPacket Microwave scenarios
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Write the IP address.
34
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
FlexiPacket Microwave scenarios
Click Next.
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
35
FlexiPacket Microwave scenarios
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Click Run .
36
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket Microwave scenarios
37
FlexiPacket Microwave scenarios
38
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
FlexiPacket Microwave scenarios
Click Next.
Check and click Next. Click Exit.
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
39
FlexiPacket Microwave scenarios
2.5. 2.5.2 2
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
IDUIDU-OD ODU U conf config igur urat atio ion n Steps
On the FlexiPacket Hub 800 disable E-CCM.
40
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
FlexiPacket Microwave scenarios
Open the ODU WebLCT and upgrade the ODU from SVR 2.4 to SVR 2.5 (starting from co-located). Switch the sw version. Close and restart the ODU WebLCT and web browser. Open again the ODU WebLCT. Change the system type to 2+2 XPIC.
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
41
FlexiPacket Microwave scenarios
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Set P-CCM.
Align the SVR loads.
42
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
FlexiPacket Microwave scenarios
Open the IDU WebLCT and create IDU E-LINE for P-CCM.
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
43
FlexiPacket Microwave scenarios
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Configure and click Next.
44
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
FlexiPacket Microwave scenarios
VLAN ID is P-CCM of ODU.
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
45
FlexiPacket Microwave scenarios
46
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
FlexiPacket Microwave scenarios
With the ODU WebLCT set for each ODU of the 4 ODU group: •
ODU role
•
ODU radio Priority
•
Switch mode
according to the ODU parameters shown in Figure 2 on page 14 (only as example).
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
47
FlexiPacket Microwave scenarios
48
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
FlexiPacket Microwave scenarios
After the setting of the 4 ODUs, set the service state to Up.
With the IDU WebLCT set the IDU synchronization in Menu Clock Sych > Create . The procedure is complete.
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
49
FlexiPacket Microwave scenarios
2.5.3
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Example: E-LAN for Ethernet traffic with VID 1000 Steps
Set the Admin Status to UP and the mode to UNI for the port GE 0/1.
50
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket Microwave scenarios
51
FlexiPacket Microwave scenarios
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Set VLAN ID to 1000.
52
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket Microwave scenarios
53
FlexiPacket Microwave scenarios
54
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket Microwave scenarios
55
FlexiPacket Microwave scenarios
2.6
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Commissioning procedure for 2+0 XPIC Ring The 2+0 XPIC Ring System Type can be implemented only with FirstMile and FlexiPacket Hub800. Two IDU solutions can be adopted: •
with Single IDU: only 1 IDU in the Station (refer to Figure 3)
•
with Two IDUs: 2 IDUs in the Station (refer to Figure 4)
Figure 3
56
Single IDU solution (example)
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Figure 4
FlexiPacket Microwave scenarios
Two IDUs solution (example)
In the Two IDUs Solution the 2 IDUs must be of the same type. In the figures the arrow shows the synch direction (clockwise). In the Ring Head NE the configured system type must be “2+0 XPIC”, in all the other NEs (Ring Node) the configured system type must be “2+0 XPIC Ring”.
2.6.1
How to configure the Ring Head NE Steps
Follow the procedure explained in document FlexiPacket Commissioning Tool, Rel. 1.3SU2, Operating Documentation, Issue 1 - A25000-A1400-D000-01-76P1 and select the System Type 2+0 XPIC . At the end of the operations in Step 1 open the ODU WebLCT and upgrade the ODU SW from SVR 2.4 to SVR 2.5. The procedure is complete.
2.6.2
How to configure the Ring Node NE Steps
Follow the procedure explained in document FlexiPacket Commissioning Tool, Rel. 1.3SU2, Operating Documentation, Issue 1 - A25000-A1400-D000-01-76P1 and select the System Type 2+0 XPIC . At the end of the operations in Step 1 open the ODU WebLCT and upgrade the ODU SW from SVR 2.4 to SVR 2.5. With the ODU WebLCT change the System Type to “ 2+0 XPIC Ring ”.
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
57
FlexiPacket Microwave scenarios
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
With the ODU WebLCT configure the Synchronization according to the information shown (as example) in Figure 3 and Figure 4. Four different configurations must be configured:
58
•
Acting Master (Radio) (refer to Figure 5)
•
Acting Slave (Radio) (refer to Figure 6)
•
Acting Master (GbE) (refer to Figure 7)
•
Acting Slave (GbE) (refer to Figure 8)
Figure 5
Acting Master (Radio) Sync Settings
Figure 6
Acting Slave (Radio) Sync Settings
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
Figure 7
Acting Master (GbE) Sync Settings
Figure 8
Acting Slave (GbE) Sync Settings
FlexiPacket Microwave scenarios
The procedure is complete.
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012
59
Acronyms and abbreviations
FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning
3 Acronyms and abbreviations BER
Bit Error Rate
BFD
Bidirectional Forwarding Detection
BGP
Border gateway Protocol
BSC
Base Station Controller
BTS
Base Transceiver Station
BW COS DSCP
Class of Service Differentiated Services Code Point
ECC
Embedded Communication Channel
ESW
Element SW
EVC
Ethernet Virtual Container
FPR
FlexiPacket Radio
HSPA IGP IMIX IP VPN
High Speed Packet Access Interior Gateway Protocol Internet Mix Traffic Virtual Private IP network
IS-IS
Dynamic routing protocol inside autonomous system
LCT
Local Craft Terminal
LDP
Label Distribution Protocol
LPG
Link Protection Group
LTE
Long Term Evolution
MGW
Media Gateway
MWR
Microwave Radio
MPLS
Multi Protocol Label Switching
Node B OSPF
WCDMA BTS (e.g. Flexi/Ultrasite WCDMA BTS) Open Shortest Path First routing protocol
PCP
Priority Code Point (p-bit)
PHB
Per Hop Behavior
PSN
Packet Switched Network
PW
60
Channel Bandwidth
Pseudo-wire
A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012