ENSAYO DE PERMEABILIDAD LUGEON

PROYECTO:

ÁREA:

PROF. DE ENSAYO DE :

ESTUDIOS COMPLETARIOS DEL ESTUDIO DE FACTIBILIDAD DE LAS CC.HH. RAPAY 1 Y RAPAY 2

258.60

FECHA :

CASA DE MAQUINAS, PIQUE VETICAL Y CHIMENEA DE EQUILIBRIO DE LA C.H. RAPAY 1

A

3/20/2015

Hr.INIC.

263.90 12:30

m.

Hr.FIN.

SONDEO N°:

DDH-CHC-CM-01

ENSAYO N°

5

14:30

LITOLOGIA DEL TRAMO:

CAUDALIMETRO Long. Min. MANOMETRO

1.00 m

hm

=

ALTURA DEL MANÓMETRO

a

=

ALTURA SOBRE NIVEL DEL TERRENO

ha

=

PROFUNDIDAD NIVEL FREÁTICO

∆h

=

SOBRECARGA HIDRÁULICA

d

=

PROFUNDIDAD DEL OBTURADOR

L

=

PROFUNDIDAD DE PERFORACIÓN

a

=

INCLINACIÓN C/HORIZONTAL

∆h'

=

∆h CORREGIDA = Sen a x ∆h

l

=

LONGITUD TRAMO DE ENSAYO

Ø

=

DIÁMETRO DEL BULBO DEL ENSAYO

Cilindro de Expansión Bomba

hm h

a

ha

e d

=

PRESIÓN MANOMETRICA

PEF

=

PRESIÓN EFECTIVA EN EL PUNTO MEDIO DEL TRAMO DEL ENSAYO

∆p

=

PERDIDAS DE CARGA

q

=

VOLUMEN DE AGUA EN LITROS POR MINUTO DURANTE EL ENSAYO

qt

=

VOLUMEN TOTAL DE AGUA EN LITROS PARA CADA ESTADIO

G

=

CAUDAL EN LITROS POR MINUTO PARA CADA ESTADIO

Q

=

UL

=

CAUDAL EN LITROS POR MINUTO POR Mt. DE TRAMO DE ENSAYO UNIDAD LUGEON ( Q x 10 / PEF )

ha

l

l/2

DIÁMETRO DE LA TUBERÍA DE ENSAYO

PM

Dh

L

0.75 1.50 175.00 175.75 258.60 263.90 90 175.75 5.30 9.6 3.06

m m m m m m ° m m cm pulg

Ø

Kg/cm2 PM =

3.00

Kg/cm2 PM =

Kg/cm2 PM =

6.00

10.00

Kg/cm2 PM =

6.00

Kg/cm2 PM =

3.00 GRÁFICO DE PATRON DE RESULTADOS PARA LA SELECCIÓN DE UNIDADES LUGEON

TIEMPO EN

LECTURA

LECTURA

MINUTO

CAUDAL.

0

830.00

1

889.00

59.00

1,676.00

76.00

2,550.00

90.00

4,394.00

74.00

5,184.00

64.00

2

950.00

61.00

1,747.00

71.00

2,641.00

91.00

4,468.00

74.00

5,247.00

63.00

3

1,009.00

59.00

1,817.00

70.00

2,732.00

91.00

4,542.00

74.00

5,311.00

64.00

4

1,070.00

61.00

1,889.00

72.00

2,822.00

90.00

4,615.00

73.00

5,375.00

64.00

5

1,124.00

54.00

1,960.00

71.00

2,913.00

91.00

4,688.00

73.00

5,439.00

64.00

6

1,182.00

58.00

2,030.00

70.00

3,004.00

91.00

4,760.00

72.00

5,501.00

62.00

7

1,240.00

58.00

2,100.00

70.00

3,095.00

91.00

4,832.00

72.00

5,564.00

63.00

8

1,296.00

56.00

2,170.00

70.00

3,186.00

91.00

4,905.00

73.00

5,627.00

63.00

9

1,354.00

58.00

2,239.00

69.00

3,277.00

91.00

4,977.00

72.00

5,690.00

63.00

10

1,410.00

56.00

2,309.00

70.00

3,368.00

91.00

5,049.00

72.00

5,753.00

q (l)

LECTURA q (l)

CAUDAL.

CAUDAL.

1,600.00

LECTURA q (l)

2,460.00

CAUDAL.

LECTURA q (l)

4,320.00

CAUDAL.

q (l)

U.L.

5,120.00 0.00

580.00

709.00

908.00

729.00

633.00

G ( l/min )

58.00

70.90

90.80

72.90

63.30

Q ( l/min/m )

10.94

13.38

17.13

13.75

11.94

∆p ( kg/cm2 )

0.04

0.06

0.10

0.07

0.05

CH(∆h'/10)

17.58

17.58

17.58

17.58

17.58

PEF ( kg/cm2 )

20.54

23.52

27.48

23.51

20.53

UL

5.33

5.69

6.24

5.85

5.82

1

2

3

4

5

REPRESENTACIÓN GRAFICA

6.00

8.00

10.00

2

3

4

5

UNIDAD LUGEON SELECCIONADA :

K

(PERMEABILIDAD):

5.85

UL

7.61E-05

cm/s

K = UL x 1.3 x 10-5 cm/seg

OBSERVACIONES:

FLUJO LAMINAR

CLASIFICACION DEL VALOR LUGEON

27.00 26.00 25.00

PEF24.00 23.00 22.00 21.00 20.00 9.00

12.00

ESTADIO

PEF = (PM - ΔP) + (Δh' / 10)

28.00

4.00

1

63.00

qt(l)

2.00

10.00

11.00

12.00

13.00

Q

14.00

15.00

16.00

17.00

18.00

CESEL INGENIEROS

GEOTECNIA PERUANA S.R.L.

ENSAYO DE PERMEABILIDAD LUGEON

PROYECTO:

PROF. DE ENSAYO DE :

PERFORACION DE MONITOREO ZONA LVUSF RIOLITA

A

FECHA :

UBICACIÓN

m.

Hr.INIC.

SONDEO N°:

Hr.FIN.

LITOLOGIA DEL TRAMO:

ENSAYO N°

6

CAUDALIMETRO Long. Min. MANOMETRO

1.00 m

hm

=

ALTURA DEL MANÓMETRO

a

=

ALTURA SOBRE NIVEL DEL TERRENO

ha

=

PROFUNDIDAD NIVEL FREÁTICO

∆h

=

SOBRECARGA HIDRÁULICA

d

=

PROFUNDIDAD DEL OBTURADOR

L

=

PROFUNDIDAD DE PERFORACIÓN

a

=

INCLINACIÓN C/HORIZONTAL

∆h'

=

∆h CORREGIDA = Sen a x ∆h

l

=

LONGITUD TRAMO DE ENSAYO

Ø

=

DIÁMETRO DEL BULBO DEL ENSAYO

Cilindro de Expansión Bomba

hm h

a

ha

e d

=

PRESIÓN MANOMETRICA

PEF

=

PRESIÓN EFECTIVA EN EL PUNTO MEDIO DEL TRAMO DEL ENSAYO

∆p

=

PERDIDAS DE CARGA

q

=

VOLUMEN DE AGUA EN LITROS POR MINUTO DURANTE EL ENSAYO

qt

=

VOLUMEN TOTAL DE AGUA EN LITROS PARA CADA ESTADIO

G

=

CAUDAL EN LITROS POR MINUTO PARA CADA ESTADIO

Q

=

UL

=

CAUDAL EN LITROS POR MINUTO POR Mt. DE TRAMO DE ENSAYO UNIDAD LUGEON ( Q x 10 / PEF )

ha

l l/2

DIÁMETRO DE LA TUBERÍA DE ENSAYO

PM

Dh

L

0.75 1.50 175.00 175.75 0.00 0.00 90 175.75 0.00 9.6 3.06

m m m m m m ° m m cm pulg

Ø

Kg/cm2 PM =

Kg/cm2 PM =

1.50

Kg/cm2 PM =

3.00

6.00

Kg/cm2 PM =

3.00

Kg/cm2 PM =

1.50 GRÁFICO DE PATRON DE RESULTADOS PARA LA SELECCIÓN DE UNIDADES LUGEON

TIEMPO EN

LECTURA

LECTURA

MINUTO

CAUDAL.

0

800.00

1

848.00

48.00

1,536.00

56.00

2,216.00

106.00

3,452.00

52.00

4,107.00

47.00

2

895.00

47.00

1,593.00

57.00

2,321.00

105.00

3,505.00

53.00

4,153.00

46.00

3

943.00

48.00

1,648.00

55.00

2,428.00

107.00

3,559.00

54.00

4,200.00

47.00

4

990.00

47.00

1,703.00

55.00

2,534.00

106.00

3,612.00

53.00

4,247.00

47.00

5

1,038.00

48.00

1,758.00

55.00

2,640.00

106.00

3,665.00

53.00

4,293.00

46.00

6

1,085.00

47.00

1,812.00

54.00

2,746.00

106.00

3,719.00

54.00

4,339.00

46.00

7

1,132.00

47.00

1,867.00

55.00

2,851.00

105.00

3,772.00

53.00

4,386.00

47.00

8

1,179.00

47.00

1,922.00

55.00

2,956.00

105.00

3,826.00

54.00

4,432.00

46.00

9

1,226.00

47.00

1,975.00

53.00

3,061.00

105.00

3,879.00

53.00

4,478.00

46.00

10

1,273.00

47.00

2,029.00

54.00

3,166.00

105.00

3,933.00

54.00

4,525.00

47.00

q (l)

CAUDAL.

LECTURA q (l)

CAUDAL.

1,480.00

qt(l)

473.00

G ( l/min )

47.30

q (l)

2110.00

549.00

Q ( l/min/m ) #DIV/0!

LECTURA CAUDAL.

LECTURA q (l)

3,400.00

1056.00

CAUDAL.

q (l)

533.00

0.00

54.90

105.60

53.30

46.50

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

0.00

0.00

0.00

0.00

0.00

CH(∆h'/10)

17.58

17.58

17.58

17.58

17.58

PEF ( kg/cm2 )

19.08

20.58

23.58

20.58

19.08

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

3

4

5

1

2

2.00

4.00

6.00

8.00

10.00

12.00

1

2

ESTADIO 3

4

5

465.00

∆p ( kg/cm2 )

U L #DIV/0!

U.L.

4,060.00

PEF = (PM - ΔP) + (Δh' / 10)

UNIDAD LUGEON SELECCIONADA :

K

(PERMEABILIDAD):

4.88

UL

6.34E-05

cm/s

K = UL x 1.3 x 10-5 cm/seg

REPRESENTACIÓN GRAFICA

OBSERVACIONES:

36.00

CLASIFICACION DEL VALOR LUGEON

34.00 32.00 30.00 28.00

PEF

26.00 24.00 22.00 20.00 18.00 8.00

9.00

10.00

11.00

12.00

Q

13.00

14.00

15.00

16.00

CESEL INGENIEROS

GEOTECNIA PERUANA S.R.L.

WATER PRESSURE TEST Job No. :

Hole No :

Client :

Antamina

Project :

Stage V Dam Raise

Location :

Antamina

0.096

Interval Top (m) :

0.00

Tested Length (m) :

0.00

Pressure Gauge Height (m agl) :

Interval Base (m) :

0.00

Pneumatic - Wireline - Double

Presumed Water Temperature :

Date :

Packer Type :

Gauge Pressure kPa

No

P5

Discharge/m (L/min/m)

0.00 48.00 47.00 48.00 47.00 48.00 47.00

0.00 48.00 47.00 48.00 47.00 48.00 47.00

0.00 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

300

1480.0 1536.0 1593.0 1648.0 1703.0 1758.0

Total : Average: 0.00 56.00 57.00 55.00 55.00 55.00

285.00 47.500 0.00 56.00 57.00 55.00 55.00 55.00

#DIV/0! #DIV/0! 0.00 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

600

0 1 2 3 4 5 6 7 8 9 10

0:00:00 0:01:00 0:02:00 0:03:00 0:04:00 0:05:00

0 01:00 01:00 01:00 01:00 01:00

2110.0 2216.0 2321.0 2428.0 2534.0 2640.0

Total : Average: 0.00 106.00 105.00 107.00 106.00 106.00

278.00 55.600 0.00 106.00 105.00 107.00 106.00 106.00

#DIV/0! #DIV/0! 0.00 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

300

0 1 2 3 4 5 6 7 8 9 10

0:00:00 0:01:00 0:02:00 0:03:00 0:04:00 0:05:00

0 01:00 01:00 01:00 01:00 01:00

3400.0 3452.0 3505.0 3559.0 3612.0 3665.0

Total : Average: 0.00 52.00 53.00 54.00 53.00 53.00

530.00 106.000 0.00 52.00 53.00 54.00 53.00 53.00

#DIV/0! #DIV/0! 0.00 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

0 1 2 3 4 5 6 7 8 9 10

0:00:00 0:01:00 0:02:00 0:03:00 0:04:00 0:05:00

0 01:00 01:00 01:00 01:00 01:00

4060.0 4107.0 4153.0 4200.0 4247.0 4293.0

Total : Average: 0.00 47.00 46.00 47.00 47.00 46.00

265.00 53.000 0.00 47.00 46.00 47.00 47.00 46.00

#DIV/0! #DIV/0! 0.00 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

Total : Average:

233.00 46.600

#DIV/0! #DIV/0!

150

TEST RESULTS

Lugeon Value Curve

Net Pressures

Flow vs. Pressure

0

2

4

6

8

10

FILE: insert file path / file name

120.0

P2

#DIV/0!

P3

#DIV/0!

P4

#DIV/0!

P5

#DIV/0!

140.1

P1

283.7

P2 Stage No. P3 P4

106.0

100.0

Gauge Pressure

Flow Rate (L/min) 80.0

521.5

60.0

285.9

40.0

H LOSS

47.5 46.6

55.6 53.0

32.95

Stage No.

c:

1

c:

1

Finish Date & Time : 04:08 March 17, 2011

kPa Average

300

kPa

Q

61.74

L/min

H

28.0

m

#DIV/0!

uL

P5

140.8

20.0

Interpreted Result

0.0

Reported Permeability at Stage Average #DIV/0!

Flow Type DILATION

Supervisor de Construcción Mota-Engil FIRMA NOMBRE FECHA

Supervisor de CQC

Supervisor de CQA

Supervisor de

Mota-Engil

Golder

Antamina

1

1

Interpreted Result & Hydraulic Conductivity

100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 550.0

12

1

c:

K = Q/2HL * ln(L/r), from Cedergren, 1989, where:

Net Interval Pressure (kPa)

Lugeon Value

#DIV/0!

Start Date & Time : 03:35 March 17, 2011 c:

where PMAX = 20 kPa/m depth below overburden/bedrock interface to a maximum of 800 kPa.

Lugeon Value

P1

Remarks c:

0 01:00 01:00 01:00 01:00 01:00

1/3 PMAX

10 76.2 1 de 2

Discharge (L/min)

0:00:00 0:01:00 0:02:00 0:03:00 0:04:00 0:05:00

2/3 PMAX

0.75

Date : Volume (L)

0 1 2 3 4 5 6 7 8 9 10

PMAX

P4

Litres

Water Meter Readings Reading (Litres) 800.0 848.0 895.0 943.0 990.0 1038.0 1085.0

150

2/3 PMAX

P3

Time Intervals (min) 0 01:00 01:00 01:00 01:00 01:00 01:00

175.00

Casing Inner Diameter (mm ) :

0 1 2 3 4 5 6 7 8 9 10

1/3 PMAX

P2

Water Meter Reading in :

Actual Time (h:m:s) 0:00:00 0:01:00 0:02:00 0:03:00 0:04:00 0:05:00 0:06:00

Used in analysis (m bgl) :

Checked By :

Rock tested :

Date : March 18, 2011

P1

Immediately prior to test (m bgl) :

Hole Diameter (m) :

Computed By :

Pressure Stage

Vertical depth to Groundwater

Drilling Method :

-90

Tested By :

Stage No.