COMMERCIAL OFFER Company

:

M/s. Bilt Middle East.

Sender

:

Ajith Sadanandan

Attention

:

Mr. Milap Doshi. (Asst. General Manager) [email protected]

Email

:

[email protected]

Mobile No.

:

+971 55 4557974

Mob. No.

:

+971-50-8138897

Tel No.

:

+ 971 4 3439798

Tel No.

:

+971-4-2544774

Date

:

Tuesday, November 29, 2016

Tyco Ref.

:

ASF/16/OPT 00516422/14972

Dear Sir, With reference to the below mentioned Scope of Work, please find attached is the Commercial Offer for Air Field & Infrastructure for EK Flight Training Organization Facilities at DWC Dubai. 1. Scope of Work The Scope of work includes the following systems for this proposed package:      

Automatic Sprinkler System Stand Pipe System & Fire Extinguishers Low Level High Expansion Foam system with Electric actuation (Detection) for Hangar Area Foam-Water Spray Deluge System with Heat Detection (5 Rooms). FM200 Clean Agent Fire Suppression System with Photo Electric Smoke Detection (13nos. Rooms). Fire alarm & detection system.



Design, Supply, Installation and Testing & Commissioning for above mentioned Systems. 2. Commercial Offer: Commercial Offer : Main Offer (Based on the design drawing issued) #

Total Price (in AED)

Description

Design, Supply, Testing and Commissioning of Equipment’s for following systems for Air Field & Infrastructure project for EK Flight Training Organization Facilities at DWC Dubai. 1

Automatic Sprinkler System Equipment.

307,687.00

2

Standpipe System Equipment and Fire Extinguishers.

419,755.00

3

High Expansion Foam system equipment with Electric actuation (Detection) for Hangar Area.

1,516,299.00

4

Deluge Foam-Water Spray System equipment with Heat Detection.

647,634.00

5

FM200 Clean Agent Fire Suppression System equipment with Photo Electric Smoke Detection.

1,162,576.00

6

Fire alarm& Detection system.

765,279.00

7

Spares & Extra materials as per specification.

473,602.00

8 9

Supply of Pipes (GI Seamless ASTM A 53 Gr. B; Sch. 40, GRE Pipes), Fittings, Supports, Cables, and Conduits & Accessories , Labor for installation Charges Complete Fire Protection, Detection & Alarm systems. Supply of Fire Station Foam Equipment’s - 2nos. 800 Gallon Foam Bladder Tank with 1595 Gallon of ANSULITE 3% AFFF (AFC-3A) Grand Total

3,309,225.00 197,829.00 8,799,886.00

(AED EIGHT MILLION SEVEN HUNDRED NINETY NINE THOUSAND EIGHT HUNDRED EIGHTY SIX.) Page 1 of 13 Head Office : P.O. Box 3333, Abu Dhabi, U.A.E. / (T) 00971 2 6777776 / (F) 00971 2 6768746 / (E) [email protected] --------------------------------------------Branch Office : P.O. Box 38163, Dubai, U.A.E. / (T) 00971 4 3805252 / (F) 00971 4 3805251 / (E) [email protected] Website : www.tycofireuae.com

3. Optional Offer: ( Not shown in the Drawings.) Commercial Offer : Optional Offer # 1 2

Total Price (in AED)

Description Design, Supply, Installation, Testing & Commissioning of FM 200 System for Unprotected Rooms – 7 Nos. Actual Discharge Test For Hangar Area High Expansion foam system, Smallest room of FM 200 system.

351,323.00 70,356.00

3

Extended Warranty for Additional 4 Years.

228,409.00

4

Design, Supply, Installation, Testing & Commissioning of Seismic Supports.

329,526.00

Grand Total

979,614.00

4. Bill Of Material for the above proposed systems: Automatic Sprinklers System Bill Of Materials # 1

Product Description

K115, Upright Sprinkler, 3/4" NPT, 93⁰C - Fast Response, Brass, UL/ FM Concealed Pendent Sprinkler Heads Concealed Pendent Sprinkler, K80, 1/2" NPT, 68⁰C - Quick Response, Chrome, C/w Series RFII Cover Plate, UL listed

3

Make

No s No s No s

414

Tyco

330

Tyco

246

Tyco

3

Tyco

6

Tyco

1

Tyco

1

Tyco

1

Tyco

1

Tyco

1

Tyco

1

NIBCO

1

Tyco

1

Tyco

1

Tyco

1

Tyco

1

Tyco

1

NIBCO

1

Tyco

Spare Sprinkler Head Cabinet & Wrench Spare Sprinkler Cabinets Standard Wrench for 1/2" NPT sprinklers

4

Quanti ty

Upright Sprinkler Heads K80, Upright Sprinkler, 1/2" NPT, 68⁰C – Fast Response, Brass, UL/ FM

2

Un it

No s No s

Alarm Check Valve Assembly Ø8" Alarm Check Valve, G X G, 300Psi, UL/ FM Ø8" Alarm check valve trim, Vertical Installation, UL/ FM Retard chamber 1/2" NPT, UL/ FM Water motor alarm Alarm pressure switch, Single contact, UL/ FM Ø8" Gate Valve, OS&Y Flange Type, UL/ FM, C/w Supervisory switch Ø6" Alarm Check Valve, G X G, 300Psi, UL/ FM Ø6" Alarm check valve trim, Vertical Installation, UL/ FM Retard chamber 1/2" NPT, UL/ FM Water motor alarm Alarm pressure switch, Single contact, UL/ FM Ø6" Gate Valve, OS&Y Flange Type, UL/ FM, C/w Supervisory switch Ø2-1/2" Alarm Check Valve, G X G, 300Psi, UL/ FM

No s No s No s No s No s No s No s No s No s No s No s No s No

Page 2 of 13 Head Office : P.O. Box 3333, Abu Dhabi, U.A.E. / (T) 00971 2 6777776 / (F) 00971 2 6768746 / (E) [email protected] --------------------------------------------Branch Office : P.O. Box 38163, Dubai, U.A.E. / (T) 00971 4 3805252 / (F) 00971 4 3805251 / (E) [email protected] Website : www.tycofireuae.com

Ø2-1/2" Alarm check valve trim, Vertical Installation, UL/ FM Retard chamber 1/2" NPT, UL/ FM Water motor alarm Alarm pressure switch, Single contact, UL/ FM

5

Ø2-1/2" Gate Valve, OS&Y Flange Type, UL/ FM, C/w Supervisory switch Zone Check valve Unit Ø8" Zone control valve Unit Ø8" Butterfly Valve, Grooved, Gearbox operated, UL/ FM Ø8" Water Flow switch UL/ FM approved Ø1" Test & Drain valve, NPT threaded, 1/2" Orifice, UL/ FM Water pressure gauge, C/w globe valve Ø1" Inspector test Connection, UL/ FM approved Ø8" Check Valve, Flanged, UL/ FM

s No s No s No s No s No s

No s No s No s No s No s No s

1

Tyco

1

Tyco

1

Tyco

1

Tyco

1

NIBCO

1

NIBCO

1

Tyco

1

Tyco

1

Tyco

1

Tyco

1

NIBCO

3

NIBCO

3

Tyco

3

Tyco

3

Tyco

3

Tyco

3

NIBCO

1

NIBCO

1

Tyco

1

Tyco

1

Tyco

1

Tyco

1

NIBCO

1

NIBCO

1

Tyco

1

Tyco

1

Tyco

1

Tyco

1

NIBCO

Ø6" Zone control valve Unit Ø6" Butterfly Valve, Grooved, Gearbox operated, UL/ FM Ø6" Water Flow switch UL/ FM approved Ø1" Test & Drain valve, NPT threaded, 1/2" Orifice, UL/ FM Water pressure gauge, C/w globe valve Ø1" Inspector test Connection, UL/ FM approved Ø6" Check Valve, Flanged, UL/ FM

No s No s No s No s No s No s

Ø3" Zone control valve Unit Ø3" Butterfly Valve, Grooved, Gearbox operated, UL/ FM Ø3" Water Flow switch UL/ FM approved Ø1" Test & Drain valve, NPT threaded, 1/2" Orifice, UL/ FM Water pressure gauge, C/w globe valve Ø1" Inspector test Connection, UL/ FM approved Ø3" Check Valve, Flanged, UL/ FM

No s No s No s No s No s No s

Ø2-1/2" Zone control valve Unit Ø2-1/2" Butterfly Valve, Grooved, Gearbox, UL/ FM Ø2-1/2" Water Flow switch UL/ FM approved Ø1" Test & Drain valve, NPT threaded, 1/2" Orifice, UL/ FM Water pressure gauge, C/w globe valve Ø1" Inspector test Connection, UL/ FM approved Ø2-1/2" Check Valve, Flanged, UL/ FM

No s No s No s No s No s No s

Page 3 of 13 Head Office : P.O. Box 3333, Abu Dhabi, U.A.E. / (T) 00971 2 6777776 / (F) 00971 2 6768746 / (E) [email protected] --------------------------------------------Branch Office : P.O. Box 38163, Dubai, U.A.E. / (T) 00971 4 3805252 / (F) 00971 4 3805251 / (E) [email protected] Website : www.tycofireuae.com

6

Breeching Inlet & Cabinet Single breeching inlet cabinet Surface Mounted Wired Glass Complete Stainless steel ( Brush316) Size:600x600x300 Breeching Inlet Ø6" X 4 way, Red painted, Kite mark Ø6" Check Valve, Flanged, UL/ FM

7

Ø8" Backflow Preventer Ø2-1/2" Gate Valve, OS&Y Flange Type, UL/ FM, C/w Supervisory switch Ø2-1/2" Check Valve, Flanged, UL/ FM

1" Ball Valve Water pressure gauge, C/w globe valve

3

NAFFCO

3

NIBCO

No s No s No s No s

3

NIBCO

3

AMES

1

NIBCO

1

NIBCO

No s No s No s

6

Tyco

6

Tyco

6

Tyco

13

Tyco

Drain Valves No s

2" Ball Valve 1 0

NAFFCO

Air Release Valve 1" Automatic Air Release Valve, UL/ FM approved

9

3

Building Isolation Valve Ø8" Gate Valve, OS&Y Flange Type, UL/ FM, C/w Supervisory switch

8

No s No s No s

Pipes, Fitting & Other accessories Supply of Pipes (Above ground: GI Seamless, Sch.40 ASTM A 53 Gr. B, Underground: GRE), Fittings, Supports, Painting and other consumables, Labor for installation, Supervision, Engineering, testing & Commissioning Charges.

Lot

1

Pipes: Shield, Fittings: National / Equivalen t

Un it

Quanti ty

Make

Stand Pipe System Bill Of Materials #

Product Description

1

Breeching Inlet & Cabinet Single breeching inlet cabinet Surface Mounted Wired Glass Complete Stainless steel ( Brush316) Size:600x600x300 Breeching Inlet Ø6" X 4 way, Kite mark approved Ø6" Check Valve, Flanged, UL/ FM

2

3

NAFFCO

3

NAFFCO

3

NIBCO

2

NIBCO

1

NIBCO

Stand Pipe riser isolation valve Ø6" Gate Valve, OS&Y Flange Type, UL/ FM, C/w Supervisory switch

3

No s No s No s

Ø2-1/2" Gate Valve, OS&Y Flange Type, UL/ FM, C/w Supervisory switch Surface mounted type Fire Hose Cabinets -FHC-1 Double vertical hose reel cabinet, surface type solid door, stainless steel 316 Facia (Mirror) 1-1/2" Landing Valve, Double female, Chrome - UL Listed 1-1/2" X 30 Mtrs Fire Hose C/W polished chrome coupling UL listed + 1 1/2" Fire Hose Rack polished Chrome finish + Rack nipple - polished chrome finish. 1-1/2" Cadmium Plated Escutcheon

No s No s No s No s

17

NAFFCO

17

ELKHART

No s

17

ELKHART

No

17

ELKHART Page 4 of 13

Head Office : P.O. Box 3333, Abu Dhabi, U.A.E. / (T) 00971 2 6777776 / (F) 00971 2 6768746 / (E) [email protected] --------------------------------------------Branch Office : P.O. Box 38163, Dubai, U.A.E. / (T) 00971 4 3805252 / (F) 00971 4 3805251 / (E) [email protected] Website : www.tycofireuae.com

1-1/2" Nozzle Polished Chrome Finish - UL 2-1/2" Landing valve double female, chrome - UL Listed 2-1/2" Female BS 336 Instantaneous Adaptor 2-1/2" X 30 Mtrs Fire Hose C/W light alloy couplings - UL Listed 2-1/2" Connecting adopter for hose & nozzle 2-1/2" nozzle chrome finish - UL Ø3" Water Flow switch UL/ FM approved 10Lbs CO2 Fire Extinguisher 10Lbs ABC with hose & horn Fire Extinguisher 4

Surface mounted type Fire Hose Cabinets -FHC-2 Double vertical hose reel cabinet, surface type solid door, stainless steel 316 Facia (Mirror) 2-1/2" Landing valve double female, chrome - UL Listed 2-1/2" Female BS 336 Instantaneous Adaptor 2-1/2" X 30 Mtrs Fire Hose C/W light alloy couplings - UL Listed 2-1/2" Connecting adopter for hose & nozzle 2-1/2" nozzle chrome finish - UL Ø3" Water Flow switch UL/ FM approved 10Lbs CO2 Fire Extinguisher 10Lbs ABC with hose & horn Fire Extinguisher

5

10Lbs ABC with hose & horn Fire Extinguisher 20Lbs CO2 Fire Extinguisher, Trolley type

1" Ball Valve Water pressure gauge, C/w globe valve

17

ELKHART

17 17 19

Local make Walker fire Local make

17

ELKHART

17

TYCO

17

AMEREX

17

AMEREX

1

NAFFCO

1

ELKHART

1 1 1

Local make Walker fire Local make

1

ELKHART

1

TYCO

1

AMEREX

1

AMEREX

No s No s No s

41

AMEREX

41

AMEREX

2

AMEREX

No s No s No s

6

Tyco

6

Tyco

6

Tyco

3

Tyco

1

Pipes: Shield, Fittings: National / Equivalen t

Drain Valves 2" Ball Valve

8

ELKHART

Air Release Valve 1" Automatic Air Release Valve, UL/ FM approved

7

No s No s No s No s No s No s No s No s No s

17

Fire Extinguishers 10Lbs CO2 Fire Extinguisher

6

s No s No s No s No s No s No s No s No s No s

No s

Pipes, Fitting & Other accessories Supply of Pipes (Above ground: GI Seamless, Sch.40 ASTM A 53 Gr. B, Underground: GRE), Fittings, Supports, Painting and other consumables, Labor for installation, Supervision, Engineering, testing & Commissioning Charges.

Lot

Page 5 of 13 Head Office : P.O. Box 3333, Abu Dhabi, U.A.E. / (T) 00971 2 6777776 / (F) 00971 2 6768746 / (E) [email protected] --------------------------------------------Branch Office : P.O. Box 38163, Dubai, U.A.E. / (T) 00971 4 3805252 / (F) 00971 4 3805251 / (E) [email protected] Website : www.tycofireuae.com

High Expansion Foam System Protected area Details: Room # Descriptio Level Building n 1

Un it

QT Y

no

1

Design Density CMM/ m2

Area m2

High Expansion Foam System Protected area Details: Hangar Area

Ground Floor

Maintenance, Repair and Overhaul Hangar

3,600.0 0

0.9

High Expansion Foam System Bill Of Materials: # 1

Product Description

Ø8" Deluge valve Electric Trimming Water motor alarm Alarm pressure switch, Double Contact, UL/ FM Solenoid valve 24VDC, 1/2" NPT Ø8" Gate Valve, OS&Y Flange Type, UL/ FM, C/w Supervisory switch

Bladder Tank Fill Pump (includes suction and clear discharge hose)

JET-X-15 Wall Relief Louver, NEMA 4

1

Tyco

1

Tyco

1

NIBCO

No s

2

Tyco/ Ansul

No s No s

2 1

Tyco/ Ansul Tyco/ Ansul

No s

2

Tyco/ Ansul

No s

2

Tyco/ Ansul

No s

2

Tyco/ Ansul

No s

2

Tyco/ Ansul

No s

2

Tyco/ Ansul

No s No s

15 15

Tyco/ Ansul Tyco/ Ansul

JET-X High Expansion Foam Concentrate JET-X 2% High Expansion Foam Concentrate, 55 Gallon Drum

1 1

Tyco

JET-X High Expansion Foam Generators High Expansion Generator, JET-X-15A (UL)

1 0

1

Hydraulic Concentrate Control Valves 2-1/2 in. Hydraulic Concentrate Ball Valve

9

Tyco

Check Valves 2-1/2 in. Swing Check Valve (brass)

8

1

Concentrate Isolation Valves 2-1/2 in. Concentrate Isolation Ball Valve,

7

Tyco

Water Inlet Valves 2-1/2 in. Water Inlet Ball Valve

6

1

Proportioner - Between Flanged Proportioner, 8 in., Flanged, 2% Jet-X

5

No s No s No s No s No s No s

Bladder Tank Accessories Sight Gauge Assembly, for 500-1500 gal. VBT

4

Make

Horizontal Bladder tanks-Foam Bladder Tank, 500 gal. Horizontal, Standard Red

3

Quanti ty

Deluge Valve Assembly Ø8" Deluge Valve, G X G, UL/ FM approved

2

Un it

No s

19

Tyco/ Ansul

36 Gallon Foam Stations Foam Station w/hose reel and nozzle (100 ft. hose), 36 gallon, CR Epoxy Red ANSULITE 3% AFFF (AFC-3A), 55 Gallon Drum

No s No

4 3

Tyco/ Ansul Tyco/ Page 6 of 13

Head Office : P.O. Box 3333, Abu Dhabi, U.A.E. / (T) 00971 2 6777776 / (F) 00971 2 6768746 / (E) [email protected] --------------------------------------------Branch Office : P.O. Box 38163, Dubai, U.A.E. / (T) 00971 4 3805252 / (F) 00971 4 3805251 / (E) [email protected] Website : www.tycofireuae.com

s 1 2

Building Isolation Valve Ø6" Gate Valve, OS&Y Flange Type, UL/ FM, C/w Supervisory switch

1 3

Ø2" Y-Strainer for High expansion Foam generator

1

NIBCO

No s No s

15

Tyco

15

DCD Approved

Drain Valves No s

2" Ball Valve 1 5

No s

Other Valves & Accessories Ø2" Gate Valve, OS&Y, Threaded, 175 psi, UL/ FM, C/w Supervisory switch

1 4

Ansul

4

Tyco

1

Pipes: Shield, Fittings: National / Equivalen t

Pipes, Fitting & Other accessories Supply of Pipes (Above ground: GI Seamless, Sch.40 ASTM A 53 Gr. B, Underground: GRE), Fittings, Supports, Painting and other consumables, Labor for installation, Supervision, Engineering, testing & Commissioning Charges.

Lot

Foam-Water Spray System Protected Rooms List: #

Room Description

Un it

QTY

Area (m2)

Design Density LPM/ m2

Foam Discharge Duration (Min)

Ground Floor

no

1

49.68

12.2

20

Ground Floor

no

1

33.00

12.2

20

no

1

51.94

12.2

20

Room No.

Level

Airfield Electrical Substation Building 1

Generator Room

G01-A

Airport Fire Station Building 2

Generator Room

G20-A

Maintenance, Repair and Overhaul Hangar Building: 3

Generator Room

G19-A

Ground Floor

MRO Hangar Utility Service Building: 4

Thinner Storage Room

G07-A

Ground Floor

no

1

14.00

12.2

20

5

Oil Storage Room

G02-A

Ground Floor

no

1

14.00

12.2

20

(NOTE: The dimension’s mentioned above are as per the drawings forwarded by Client. Any change to dimension’s later-on will bring about changes commercially if necessary.)

Foam-Water Spray System Description: The proposed Deluge Foam-Water Spray System shall be provided for above mentioned rooms. The system to be designed to provide adequate proportioned foam – water solution at Design Density of 12.20 LPM/M² over the entire protected areas with foam discharge duration of 20 minutes. FM200 Clean agent System Protected room details: (As per Design drawings) #

Room Description

Level

Void

Area (m2)

Height (m)

Volume (m3)

Airfield Electrical Substation Building: 1

CCR Room-G07-A

Ground

Room void Trench

77.76 30.00

5.10 1.25

396.58 37.50

2

Control Room-G08-F

Ground

Room void

25.92

5.10

132.19

Room void

77.76

5.10

396.58

Trench Room void

20.30 90.72

1.25 5.10

25.38 462.67

3

MV Room-G02-A

Ground

4

LV Room-G04-A

Ground

Page 7 of 13 Head Office : P.O. Box 3333, Abu Dhabi, U.A.E. / (T) 00971 2 6777776 / (F) 00971 2 6768746 / (E) [email protected] --------------------------------------------Branch Office : P.O. Box 38163, Dubai, U.A.E. / (T) 00971 4 3805252 / (F) 00971 4 3805251 / (E) [email protected] Website : www.tycofireuae.com

FM200 Clean agent System Protected room details: (As per Design drawings) #

Room Description

Level

Void

Volume (m3)

Area (m2)

Height (m)

Trench

46.00

1.25

57.50

Room void

87.12

5.30

461.74

Trench

50.00

1.250

Room void

23.76

5.30

125.93

Trench

16.00

1.25

20.00

Room void

37.29

2.28

85.02

Ceiling Void

37.29

1.13

42.14

Floor Void

37.29

0.70

26.11

Room void

19.47

2.28

44.39

Ceiling Void

19.47

1.13

22.00

Floor Void

19.47

0.70

13.63

Room void

57.50

3.25

186.88

Room void

95.00

5.10

484.50

Trench

42.00

1.25

52.50

Room void

61.74

5.10

314.87

Trench

12.60

1.25

15.75

Airfield Electrical Substation Building: Airport Fire Station Building: 5

LV Room-G19-A

Ground

6

MV Room-G04-A

Ground

7

Equipment Room-F04-H

1st Floor

8

LV Room-F12-H

1st Floor

9

VCR-S01-H

VCR Level

62.50

Maintenance, Repair and Overhaul Hangar Building: 1 0 1 1 1 2 1 3

LV Room-G16-A

Ground

MV Room-G17-A

Ground

Batteries Room-G23-B

Ground

Room void

29.76

5.10

151.78

Dangerous Goods-G25A

Ground

Room void

13.50

5.10

68.85

(NOTE: The dimension’s mentioned above are as per the drawings and Room List forwarded by Client. Any change to dimension’s later-on will bring about changes commercially if necessary.)

FM200 Clean agent System Protected room details: (Optional Rooms) #

Room Description

Level

Void

Area (m2)

Height (m)

4.96

5.30

Volume (m3)

Airport Fire Station Building: 1

Tel. Room-G09-E

Ground

Room void

26.29

Maintenance, Repair and Overhaul Hangar Building: 2

Tel. Room-G03-E

Ground

Room void

17.60

5.10

89.76

3

MV Room-G17-A

Ground

Room void

36.30

5.10

185.13

4

Elec. Room-F06-E

1st Floor

Room void

20.50

3.93

80.57

5

Tel. Room-F21-E

1st Floor

Room void

9.30

3.93

36.55

6

BMS Room-F07-F

1 Floor

Room void

26.68

3.93

104.85

Room void

6.16

5.10

31.42

st

MRO Hangar Utility Service Building: 7

Elec. Room-G06-A

Ground

(NOTE: The dimension’s mentioned above are as per the drawings and Room List forwarded by Client. Any change to dimension’s later-on will bring about changes commercially if necessary.)

FM200 System Description The proposed FM200 Fire Suppression System will protect the above room by Stand Alone System with Main & Reserved Cylinders and the cylinders will be placed inside/outside the protected rooms in an appropriate location. The system proposed is a total flooding, FM200 system designed in accordance with manufacturer standards with Design Concentration of 7.1% and flooding factor of 0.5562 @ 21°C. The FM200 System protected room is provided with a stand-alone (conventional) extinguishing release control panel connected with detectors, abort switch, pull station, alarm bells and sounders / flashers. 1st stage alarm sounders are provided inside the protected risk and 2nd stage flasher outside the room is provided. Page 8 of 13 Head Office : P.O. Box 3333, Abu Dhabi, U.A.E. / (T) 00971 2 6777776 / (F) 00971 2 6768746 / (E) [email protected] --------------------------------------------Branch Office : P.O. Box 38163, Dubai, U.A.E. / (T) 00971 4 3805252 / (F) 00971 4 3805251 / (E) [email protected] Website : www.tycofireuae.com

The release control panel has a fire/fault volt free contact output that can be interface to existing Building FACP by others. The FM200 system can be activated by; Automatic Release from the Releasing Panel & Smoke Detectors Manual Release (Electrical) at the Manual Release Station Addressable Fire Alarm& detection System

1

Main Fire alarm control panel (FACP) with battery& power supply.

UNI T No

2

Sub Fire alarm control panel (FACP) with battery& power supply.

No

3

3

Graphic station with PC,BAC net interface, Printer

Lot

1

4

Optical smoke detector with standard base

No

116

5

Optical smoke detector with Void

No

58

6

Response indicator

No

58

7

Intrinsic safe smoke detector

No

1

8

Heat Detector with standard base

No

5

9

#

Description

Quantit y 1

Multi sensor detector

No

14

10

Triple IR Flame detector

No

13

11

Beam detector

No

2

12

Gas detector

No

1

13

Double action manual call point

No

34

14

Double action manual call point W/P

No

25

15

Fire alarm bell

No

42

16

Fire alarm bell Outdoor

No

7

17

Fire alarm sounder

No

12

18

Ceiling strobe S1

No

34

19

Ceiling strobe S2

No

1

20

Ceiling strobe S3

No

1

21

Wall mounted strobe S1

No

17

22

Wall mounted strobe S2

No

4

23

Wall mounted strobe S3

No

9

24

Monitor module

No

186

25

Relay module

No

53

26

Isolator Module

No

49

27

Installation tools

Lot

1

28

Spare parts 2%

Lot

1

29

LHS cable with controller for Hanger area

Lot

1

30

VLF 250 VESDA detector

No

3

31

PIPIES&ACCESSORIES for VESDA

Lot

1

5. Brand offered: Mechanical Hardware: Sprinklers, Alarm valve Stand Pipe equipment Fire Extinguishers FM 200 Gas Suppression Pipes

: Tyco Safety Products, UL/FM Approved. : ELKHART : AMREX, UL/ FM approved : Tyco Safety Products, UL/FM Approved. : Shield, UL / FM Approved.

Electrical Hardware: Fire Detection & Alarm System : Tyco Safety Products, UL Listed. VESDA : Xtralis, UL Listed. Page 9 of 13 Head Office : P.O. Box 3333, Abu Dhabi, U.A.E. / (T) 00971 2 6777776 / (F) 00971 2 6768746 / (E) [email protected] --------------------------------------------Branch Office : P.O. Box 38163, Dubai, U.A.E. / (T) 00971 4 3805252 / (F) 00971 4 3805251 / (E) [email protected] Website : www.tycofireuae.com

6. Terms & Conditions: Payment Price Delivery FF Hardware’s Delivery FA Hardware’s Payment Terms

: : : : :

To be Discussed In UAE Dirham 08 – 12 Weeks (After Official Design Approval) 10 – 12 Weeks (After Official Design Approval) To be confirmed upon credit approval process

This commercial offer is made in accordance with the Tyco UAE Terms and Conditions of Sale, Which can be downloaded from the following web page:http://www.tycofireuae.com/Products-Solutions/solutions-services 7. Reference Drawings List: Fire Fighting System #

Drawing No.

Drawing Title.

1

D14010-0100D-TD-MF-MRO101

Maintenance, Repair and Overhaul Hangar Ground Floor Level FIRE FIGHTING

2

D14010-0100D-TD-MF-MRO102

Maintenance, Repair and Overhaul Hangar First Floor Level FIRE FIGHTING

3

D14010-0100D-TD-MF-MRO103

Maintenance, Repair and Overhaul Hangar Top of Roof Level FIRE FIGHTING

4

D14010-0100D-TD-MF-MRO121

MRO Utility Service Block Plans FIRE FIGHTING

5

D14010-0100D-TD-MF-MRO701

Maintenance, Repair and Overhaul Hangar RISER DIAGRAM FIRE FIGHTING

6

D14010-0100D-TD-MF-AFS-101

Airport Fire Station Ground Floor Level FIRE FIGHTING

7

D14010-0100D-TD-MF-AFS-102

Airport Fire Station First Floor Level FIRE FIGHTING

8

D14010-0100D-TD-MF-AFS-103

Airport Fire Station Intermediate Floor Level FIRE FIGHTING

9

D14010-0100D-TD-MF-AFS-104

Airport Fire Station VCR Floor Level FIRE FIGHTING

10

D14010-0100D-TD-MF-AFS-701

Airport Fire Station RISER DIAGRAM FIRE FIGHTING

11

D14010-0100D-TD-MF-AES-101

Airfield Electrical Substation Plans FIRE FIGHTING

Rev / Date Rev 02/ 20.11.20 15 Rev 02/ 20.11.20 15 Rev 01/ 20.11.20 15 Rev 01/ 12.05.20 15 Rev 01/ 12.05.20 15 Rev 02/ 20.11.20 15 Rev 02/ 20.11.20 15 Rev 01/ 20.11.20 15 Rev 01/ 20.11.20 15 Rev 01/ 20.11.20 15 Rev 00/ 27.04.20 15

Fire Alarm System #

Drawing No.

Drawing Title.

1

D14010-0100D-TD-E-MRO-401

Maintenance, Repair and Overhaul Hangar Ground Floor Level FIRE ALARM LAYOUT

2

D14010-0100D-TD-E-MRO-402

Maintenance, Repair and Overhaul Hangar First Floor Level FIRE ALARM LAYOUT

3

D14010-0100D-TD-E-MRO-702

Maintenance, Repair and Overhaul Hangar ELV schematic diagram sheet 1 of 3

4

D14010-0100D-TD-E-MRO-704

Maintenance, Repair and Overhaul Hangar ELV schematic diagram sheet 3 of 3

Rev / Date Rev 01/ 20.11.20 15 Rev 01/ 20.11.20 15 Rev 00/ 27.04.20 15 Rev 00/ 27.04.20 Page 10 of 13

Head Office : P.O. Box 3333, Abu Dhabi, U.A.E. / (T) 00971 2 6777776 / (F) 00971 2 6768746 / (E) [email protected] --------------------------------------------Branch Office : P.O. Box 38163, Dubai, U.A.E. / (T) 00971 4 3805252 / (F) 00971 4 3805251 / (E) [email protected] Website : www.tycofireuae.com

15 5

D14010-0100D-TD-E-AFS-401

Airport Fire Station Ground Floor Level FIRE ALARM LAYOUT

6

D14010-0100D-TD-E-AFS-402

Airport Fire Station First Floor Level FIRE ALARM LAYOUT

7

D14010-0100D-TD-E-AFS-403

Airport Fire Station Intermediate Floor Level FIRE ALARM LAYOUT

8

D14010-0100D-TD-E-AFS-703

Airport Fire Station ELV Schematic diagram sheet 2 of 2

Rev 01/ 20.11.20 15 Rev 01/ 20.11.20 15 Rev 01/ 20.11.20 15 Rev 01/ 20.11.20 15

8. Inclusions & Consideration:                



This offer is based on the Drawings and Specifications provided. If it should prove necessary to amend our proposals, when more detailed information becomes available, major changes in comparison with the present information, we reserve the right to amend our quotation accordingly. We are proposing our standard Products as mentioned in section-6, Since Vendor list are not available. Proposed Fire Hose cabinets are solid door type only. Size, thickness and finishing are as per manufacturer’s standard only. Any changes in Drawings and Room Schedule provided and its description type more than our proposal will be consider as additional cost. Room dimension for FM200 Clean agent Fire Suppression System and Foam Water Spray Deluge System are as per the drawings provided along with the enquiry. Any changes on the dimension that will affect our gas calculation and costing, we reserve to amend the quote accordingly. FM200 storage containers (red epoxy polyester finish) are designed to hold FM200 in liquid form and Nitrogen, which is used to super-pressurize the container to 24.8 bar (360 psi) at 20 deg. C We assume that FM200 rooms are sealed to contain the gas inside the risks protected. Closing of all openings into the room and any other openings that might dilute or allow the escape of the extinguishing gas is by others. Extinguishing Panel Enclosure for FM200 System is Surface Mounted, IP30, 1.2mm mild sheet steel, Epoxy powder coated Red RAL 3002, 230 Vac and not IP21 to IEC 60529, enameled steel cabinet 06 Lamps Status Unit indicating/ illuminating status of the system will be provided outside each protected FM200 Space and not a Graphic Annunciator type of panel. Stand by Power for the FM200 Extinguishing Panel is Lead Acid Batteries for 24 Hours only and not 72 Hours. Photoelectric Smoke Detectors has been considered (and not Ionization Type) for the smoke detection part of FM200 Protected Space and Detector, Heat, Rate Compensated, 140º F, Vert. for the Foam Water Spray Deluge System protected space. We have considered the Tie-In connection from existing network is taken from Isolation Valve Outlet. Any live tapping or any draining requirement shall be carried out by additional cost. Proposed above ground pipes for Water based system as GI. Seamless ASTM A. 53 Gr. B Sch. 40, and for Clean agent system GI. Seamless ASTM A 53 Gr. B Sch. 40. We have considered Galvanized 3000 lbs. forged steel fittings for the FM200 System. For interfacing with other systems – only one volt free contacts in extinguishing control panel &Fire alarm panel are available. Interfacing are only available for the below mentioned points A. Common Fire B. Common Fault C. Gas Release Signal D. 1st Stage Alarm E. 2nd Stage Alarm *Any additional interfacing requirements if required can be provided at additional cost. The discharge nozzles for the proposed FM200 System shall be Brass and not Stainless Steel. Page 11 of 13 Head Office : P.O. Box 3333, Abu Dhabi, U.A.E. / (T) 00971 2 6777776 / (F) 00971 2 6768746 / (E) [email protected] --------------------------------------------Branch Office : P.O. Box 38163, Dubai, U.A.E. / (T) 00971 4 3805252 / (F) 00971 4 3805251 / (E) [email protected] Website : www.tycofireuae.com

        

      

Interfacing module for HVAC, Firefighting, Exhaust fans is approximate quantity will be taken in our offer (details not provided) We have Proposed MFACP located at MRO building, other building considered for SUB fire alarm panel. Single graphic station with PC with printer considered for MRO building. VESDA panel considered for telecom room based on the drawings. Interfacing with fire alarm panel. We have considered Fire rated FP200 cables for Fire detection& alarm system. All components are suitable for indoor/ outdoor & safe environment and not flameproof / explosion proof. All equipment proposed is Civil defense approved. Design Documentation like Design Drawing and Technical Submittal, Operation & Maintenance Manual are included in the offer. Room Integrity Test: Any gas extinguishing system should have room integrity to establish the pressure retention properties of the room. This test shall establish the ability of the room to retain the gas & also if a vent is required. We have included for integrity testing for all the FM200 Gas Fire Suppression System protected areas in our offer. However, if the initial test may fail, we shall provide a second Room Integrity Test which shall incur variation. All items quoted in our offer is strictly based on the drawings. Any item not mentioned in our quotation is not part of our offer and will be quoted separately if required. Any interpretation or variation other than the above should be brought to our notice based on which our offer will be revised. Procurement of system equipment’s is after approval of Technical Submittal and Design Drawings & Calculations from Consultants. Our standard warranty will be for 12 months from the date of commissioning the systems against manufacturing defects. Material Submittals and datasheets shall be provided against order confirmation. For approval of System Design Drawings by Civil Defense; our scope is limited to providing all necessary supporting documents and liaising with CD office for such approvals. Any Fees levied for approval shall be paid by the customer at actual to CD. As Built Drawings. 9. Exclusions:

                  

All kind of Civil Works, Grouting, Pipe sleeves, Fire sealant, Valve chambers and Pit covers, Escutcheons, Concrete thrust blocks, Hume pipes for Road crossing, Excavation, Backfilling, any type of foundations and Poles. Any Works related Structural, Electrical; any other mechanical which is not comes under fire protection scope. Manlift/Scissor Lift for access above 3 meters height installation works. Crane/Fork Lift Any other equipment/ instrument/ materials other than provided BOQ. Seismic supports and Seismic restrained system, Building expansion joints. Sway bracing supports, Secondary Structural supports for Sprinkler and Firefighting piping. Design, Supply, Installation, Testing & Commissioning of Fire water storage tank & Tank accessories, Fire pump sets, Pump room building, Plinths, etc., Since fire water is tapped from Existing network. Post indicators for External Underground valves. Sprinkler indicator panel. Weight contact device underneath the fire extinguishers in the Fire hose cabinets are excluded. Extract Fan, Pressure Relief, Smoke Clearance Ventilation, Drop/Louver Curtains & Fire/Smoke Damper. Automatic/Magnetic Door Closure/Holder/Release. Pressure Relief / Automatic Fire dampers in air conditioning ductwork are excluded. Pressure reducing station is excluded since not indicated in the design drawings. Actual Discharge Test for FM200 and Foam Water Spray Deluge System & Factory acceptance test. Stand by Power of 72 hours for the Extinguishing/ Release Panels. Temporary Fire Fighting System. Remote annunciation to the building security system and illuminate LED light on graphic annunciator for FM200 and Foam Fire Suppression System. Any type of Pneumatic/ Nitrogen Filled/ Pilot Cylinders for actuation of the FM200 Fire Suppression System. Page 12 of 13 Head Office : P.O. Box 3333, Abu Dhabi, U.A.E. / (T) 00971 2 6777776 / (F) 00971 2 6768746 / (E) [email protected] --------------------------------------------Branch Office : P.O. Box 38163, Dubai, U.A.E. / (T) 00971 4 3805252 / (F) 00971 4 3805251 / (E) [email protected] Website : www.tycofireuae.com



                    

Interfacing and cabling works of FM200 and Foam Fire Suppression System to other third party equipment / Systems (HVAC, Dampers, BMS, SCADA, Discharge of FM200 Gas shall shut down power the equipment within the protected area, Closing of Supply return dampers and local AHU shall be shutdown wherever and whichever is applicable). Any other interfacing requirements other than the point highlighted in Inclusions and Considerations. Containment (Cable trays/ Trunking/MICC Cables) for Fire Alarm has not been considered part of this offer. Incoming power cable, isolator / MCCB and ear thing for extinguishing panel, Fire alarm panel and detection system for Clean Agent System. Earth / Electrical Continuity test for Pipe work within the Firefighting system equipment Water, Power/ Electricity at site required during testing and commissioning of the systems. Interface with existing DWC airport facility Edwards make fire alarm panel shall be excluded from our scope of works. Fire alarm panel having in build Amplifier module& fire telephone modules are not considered. Auto Dialer/ 24 X 7 Civil defense Panel. Interface with CCTV, Security, Access Control, Smoke management station since details is not provided, as per system requirement if any additional modules is required to integrate fire alarm panel with other system will be extra cost applicable. Repeater or Annunciator Panel/MIMIC Panel. Duct Detector, Emergency & exit Light system (Self-contained or Central battery), Voice Evacuation System, Public address system, CO detector, Firefighting Telephone System. Networking & Graphic control station for VESDA Passive Fire Protection (Fire Proof Paint, Fire Doors, Fire Proof Sealant) and Earthling of Fire Fighting Pipes. Maintenance Breathing Apparatus & Personal Safety Equipment. Any type of Government/ Civil Defense fees. Charges related to third party inspection/client inspection, Air fares, travels, boarding/lodging, accommodations, foods, etc. Site office, Site stores for Material storage. QA/ QHSE/ HSC provided by Main contractor. Coordination with other services. Third party consultant approval.

We trust our offer meets with your acceptance and we look forward for your valuable order. Should you need any further assistance, please feel free to contact the undersigned on +971-4-2544774 Regards,

For tyco Fire & Security UAE L.L.C

Ajith Sadanandan Sales Manager

Page 13 of 13 Head Office : P.O. Box 3333, Abu Dhabi, U.A.E. / (T) 00971 2 6777776 / (F) 00971 2 6768746 / (E) [email protected] --------------------------------------------Branch Office : P.O. Box 38163, Dubai, U.A.E. / (T) 00971 4 3805252 / (F) 00971 4 3805251 / (E) [email protected] Website : www.tycofireuae.com