VOLUMETRIC MASS TRANSFER COEFFICIENTS (kLa) IN FERMENTATION SYSTEMS
FACTORS AFFECTING THE VALUES OF MASS TRANSFER COEFFICIENTS IN FERMENTATION SYSTEMS •Various operating parameters and physico-chemical properties of fermentation broth affects mass transfer rate, which in turn show effect on kLa.
Factors affecting the value of kLa are: 1. Bubble size
8.Pressure
2.Gas Hold-up 9. Antifoaming agents
3.Gas Velocity 10. Presence of cells 4.Type of gas sparger
11. Surface active solutes 5.Type of agitation 6. Power input to agitator
7.Temperature
1.Bubble size
•Bubble size has great effect on kLa as the gas is sparged discretely into the fermentation broth in the form of small bubbles. •Small bubbles have high interfacial area. No.of bubbles
Bubble volume (mm3)
Bubble Diameter (mm)
Surface Area (mm2)
Increase in area (%)
1
4.19
2
12.57
-
2
2X2.1
1.59
2X7.91
26.0
3
3X1.4
1.39
3X6.0
44.2
Effect of bubble size on interfacial area and various other parameters Bubble Dia
a
kL
Bubble rise velocity
Gas Holdup
Internal recirculation
Bubble rigidity
Big
Small
High
High
Less
Yes
No
Small
High
Small
Low
High
No
Yes
2. Gas Hold-up
Gas Hold-up is the volume fraction of the gas held up in the total volume comprising the liquid and the held-up gas together. e= VG/(VG+VL) = VG/V Higher values of e indicates higher amount of gas held up in the system. Smaller bubbles (dB
Thank you for interesting in our services. We are a non-profit group that run this website to share documents. We need your help to maintenance this website.