Download Example Calculations for Purlins [Ver 1.1 1098]...
Description
Example Calculations for Purlins [ver 1.1 1098]
Example Calculations for Purlins REQUIREMENTS Select Z-section member size for Dead + Live and Dead + Wind load combinations for metal building purlins. Select sections for each of the following lateral stability conditions: both flanges continuously braced through-fastened (See pages I-B-1 to I-B-3 for a definition of through-fastened condition.) both flanges laterally braced at intervals specified in four span Laterally Braced Capacities tables in Part III. Deflection and web crippling will not be considered in this example. DESIGN INFORMATION For this example, purlins are designed as continuous over all interior supports with pinned supports at the endwalls. Because web crippling is ignored in this example, forces from supports must be transferred directly to the web of the purlin sections by way of a clip that bolts to the purlin web. DETERMINE UNIFORM WIND LOAD 2 16 25
ft. ft.
Roof slope Sidewall height Purlin span
5 125
ft. sq. ft.
Tributary length supported by purlin Support area for purlin
Determine support area for purlin
Determine external pressure coefficients GCp Reference BOCA, Figure 1609.8.1(2), page 175, using area 1. Positive values are toward the surface. BOCA has no provisions for positive wind pressure to purlins for buildings with roof slopes of less than 30 degrees. -1.2 Negative external pressure coefficient Determine internal pressure coefficients GCpi Reference BOCA, Table 1609.7(6), page 173. .25 VIII-C-3 Figure VIII-C-1: PRESSURE COEFFICIENTS
Arch or dome with rise of 1/8 of span or less than 3/8 of span Rise 12 inches per foot(1:1) and greater Arch or dome with rise 3/8 of span or greater
20
Example Calculations for Purlins [ver 1.1 1098]
Trial section: 8 X 2.5 Z 16 G Compute member loads for current trial section 5 2.796 0.559
ft. lb/ft. psf
Purlin spacing Purlin weight Purlin dead load
0.92 107.396
psf lb/ft.
Panel weight Uniform purlin positive load
-67.041
lb/ft.
Uniform purlin negative load
VIII-C-5
15 October 1998
CHECK CAPACITIES AGAINST APPLIED LOADS Successful sections are indicated by Bold Italics. Condition
Load Direction
Continuously braced
Section Capacity (lb/ft.)
Throughfastened
Laterally braced
page III-K-44
109
page III-K-44
0 33 11 33 0
**
0 33 11 33 0
109
Positive (down) Negative (up)
Reference
109
Positive (down) Negative (up)
Laps
Positive down Negative (up)
Applied Load (lb/ft.)
89
0 33 11 33 0
89
page III-N-109
** Apply .7 reduction factor for through-fastened. The trial section has a capacity greater than the applied load in the continuously braced and through-fastened conditions. Therefore, the section passes for these conditions. The section capacity is less than the applied for the laterally braced condition. Additional trials are necessary to find an adequate section for this condition. Laterally braced: It is necessary to find a section that will carry 107.396 ignoring differences in dead load of the section. Options are: 8 X 2.5 Z 14 G @ 374 lb 8 X 3.0 Z 15 G @ 379 lb 8 X 3.5 Z 16 G @ 367 lb Trial section: 8 X 3.5 Z 16 G Condition Laterally braced
RECOMPUTE LOADS FOR CURRENT TRIAL SECTIONS Use exact section weights. Continuously braced: Trial section: 8 X 2.5 Z 16 G (no change from initial trial)