http://www.oracle.com/technetwork/articles/oem/exadata-commands-part1-402441.html http://www.oracle.com/technetwork/articles/oem/exadata-commands-part2-402442.html http://www.oracle.com/technetwork/articles/oem/exadata-commands-part3-402445.html http://www.oracle.com/technetwork/articles/oem/exadata-commands-part4-402446.html
Oracle Exadata Commands Reference
Part 1: Jumpstarting on Exadata by Arup Nanda Know your Oracle Exadata Database Machine and understand the building blocks where commands will be applied. > Back to Series TOC (Note: The purpose of this guide is educational; it is not intended to replace official Oracle-provided manuals or other documentation. The information in this guide is not validated by Oracle, is not supported by Oracle, and should only be used at your own risk.)
Let's begin with a whirlwind tour of the Oracle Exadata Database Machine. It comes in a rack with the components that make up a database infrastructure: disks, servers, networking gear, and so on. Three configuration types are available: full rack (see below), half rack, or quarter rack. The architecture is identical across all three types but the number of components differs.
Figure 1 Exadata Components, high-level view, at time of writing
Now let's dive into each of these components and the role they play. The following list applies to a full rack; you can also view them contextually via a really neat 3D demo. • Database Nodes – The Exadata Database Machine runs Oracle Database 11g Real Application Cluster. The cluster and the database run on the servers known as database nodes or compute nodes (or simply “nodes”). A full rack has 8 nodes running Oracle Linux or Oracle Solaris. • Storage cells - The disks are not attached to the database compute nodes, as is normally the case with the direct attached storage, but rather to a different server known as the storage cell (or just “cell”; there are 14 of them in a full rack). The Oracle Exadata Server Software runs in these cells on top of the OS. • Disks – each cell has 12 disks. Depending on the configuration, these disks are either 600GB high performance or 2TB high capacity (GB here means 1 billion bytes, not 1024MB). You have a choice in the disk type while making the purchase. • Flash disks – each cell also has 384GB of flash disks. These disks can be presented to the compute nodes as storage (to be used by the database) or used a secondary cache for the database cluster (called smart cache). • Infiniband circuitry – the cells and nodes are connected through infiniband for speed and low latency. There are 3 infiniband switches for redundancy and throughput. Note: there are no fiber switches since there is no fiber component. • Ethernet switch – the outside world can communicate via infiniband, or by Ethernet. There is a set of Ethernet switches with ports open to the outside. The clients may connect to the nodes using Ethernet. DMAs and others connect to the nodes and cells using Ethernet as well. Backups are preferably via infiniband but they can be done through network as well. • KVM switch – there is a keyboard, video, and mouse switch to get direct access to the nodes and cells physically. This is used initially while setting up and when the network to the system is not available. In a normal environment you will not need to go near the rack and access this KVM, not even for powering on and off the cells and nodes. Why not? You’ll learn why in the next installment. (Not all models have a KVM switch.) The nodes run the Oracle Clusterware, the ASM instances, and the database instances. You may decide to create just one cluster or multiple ones. Similarly you may decide to create a single database on the cluster or multiple ones. If you were to create three databases – dev, int and QA - you would have two choices:
•
One cluster – create one cluster and create the three databases
•
Three clusters – create three different clusters and one database in each of them
The first option allows you to add and remove instances of a database easily. For instance, with 8 nodes in a full rack, you may assign 2 nodes to dev, 2 to int, and 4 to QA. Suppose a full-fledged production stress test is planned and that temporarily needs all 8 nodes in QA to match 8 nodes in production. In this configuration, all you have to do is shut down the dev and int instances and start the other four instances of QA on those nodes. Once the stress test is complete, you can shut down those 4 QA instances and restart the dev and int instances on them. If you run multiple production databases on a single rack of Exadata, you can still take advantage of this technique. If a specific database needs additional computing power temporarily to ride out a seasonal high demand, just shut down one instance of a different database and restart the instance of the more demanding one in that node. After the demand has waned, you can reverse the situation. You can also run two instances in the same node but they will compete for the resources – something you may not want. At the I/O level, you can control the resource usage by the instances using the IO Resource Manager (IORM). On the other hand, with this option, you are still on just one cluster. When you upgrade the cluster, all the databases will need to be upgraded. The second option obviates that; there are individual clusters for each database – a complete separation. You can upgrade them or manipulate them any way you want without affecting the others. However, when you need additional computational power for other nodes, you can’t just start up an instance. You need to remove a node from that cluster and add the node to the other cluster where it is needed – an activity more complex compared to the simple shutdown and startup of instances. Since the cells have the disks, how do the database compute nodes access them - or more specifically, how do the ASM instances running on the compute nodes access the disks? Well, the disks are presented to cells only, not to the compute nodes. The compute nodes see the disks through the cells. For the lack of a better analogy,
this is akin to network-attached storage. (Please note, the cell disks are not presented as NAS; this is just an analogy.) The flash disks are presented to the cell as storage devices as well, just like the normal disks. As a result they can be added to the pool of ASM disks to be used in the database for ultra fast access, or they can be used to create the smart flash cache layer, which is a secondary cache between database buffer cache and the storage. This layer caches the most used objects but does not follow the same algorithm as the database buffer cache, where everything is cached first before sending to the end user. Smart flash cache caches only those data items which are accessed frequently – hence the term “smart” in the name. The request for data not found in the smart flash cache is routed to disks automatically. The Secret Sauce: Exadata Storage Server So, you may be wondering, what’s the “secret sauce” for the Exadata Database Machine’s amazing performance? A suite of software known as Exadata Storage Server, which runs on the storage cells, is the primary reason behind that performance. In this section we will go over the components of the storage server very briefly (not a substitute for documentation!).
Cell Offloading The storage in the Exadata Database Machine is not just dumb storage. The storage cells are intelligent enough to process some workload inside them, saving the database nodes from that work. This process is referred to as cell offloading. The exact nature of the offloaded activity is discussed in the following section.
Smart Scan In a traditional Oracle database, when a user selects a row or even a single column in a row, the entire block containing that row is fetched from the disk to the buffer cache, and the selected row (or column, as the case may be) is then extracted from the block and presented to the user’s session. In the Exadata Database Machine, this process holds true for most types of access, except a very important few. Direct path accesses – for instance, full table scans and full index scans – are done differently. The Exadata Database Machine can pull the specific rows (or columns) from the disks directly and send them to the database nodes. This functionality is known as Smart Scan. It results in huge savings in I/O. For instance your query might satisfy only 1,000 rows out of 1 billion but a full table scans in a traditional database retrieves all the blocks and filters the rows from them. Smart Scan, on the other hand, will extract only those 1,000 rows (or even specific columns from those rows, if those are requested) – potentially cutting I/O by 10 million times! The cell offloading enables the cells to accomplish this. Not all the queries can take advantage of Smart Scan. Direct buffer reads can. An example of such queries is a full table scan. An index scan will look into index blocks first and then the table blocks – so, Smart Scan is not used.
iDB How can storage cells know what columns and rows to filter from the data? This is done by another component inherently built into the storage software. The communication between nodes and cells employ a specially developed protocol called iDB (short for Intelligent Database). This protocol not only request the blocks (as it happens in an I/O call in a traditional database) but can optionally send other relevant information. In those cases where Smart Scan is possible, iDB sends the names the table, columns, predicates and other relevant information on the query. This information allows the cell to learn a lot more about the query instead of just the address of the blocks to retrieve. Similarly, the cells can send the row and column data instead of the traditional Oracle blocks using iDB.
Storage Indexes How does Smart Scan achieve sending only those relevant rows and columns instead of blocks? A special data structure built on the pattern of the data within the storage cells enables this. For a specific segment, it stores the minimum, maximum, and whether nulls are present for all the columns of that segment in a specified region of the disk, usually 1MB in size. This data structure is called a storage index. When a cell gets a Smart Scanenabled query from the database node via iDB, it checks which regions of the storage will not contain the data. For instance if the query predicate states where rating = 3, a region on the disk where the minimum and maximum values of the column RATING are 4 and 10 respectively will definitely not have any row that will match the predicate. Therefore the cell skips reading that portion of the disk. Checking the storage index, the cell
excludes a lot of regions that will not contain that value and therefore saves a lot of I/O. Although it has the word “index” in its name, a storage index is nothing like a normal index. Normal indexes are used to zero in on the locations where the rows are most likely to be found; storage indexes are used just for the opposite reason – where the rows are most likely not to be found. Also, unlike other segments, these are not stored on the disks; they reside in memory.
Smart Cache Database buffer cache is where the data blocks come in before being shipped to the end user. If the data is found there, a trip to the storage is saved. However, if it not found, which might be the case in case of large databases, the I/O will inevitably come in. In Exadata Database Machine, a secondary cache can come in between the database buffer cache and the storage, called Smart Cache. The smart cache holds frequently accessed data and may satisfy the request from the database node from this cache instead of going to the disks – improving performance.
Infiniband Network This is the network inside the Exadata Database Machine – the nervous system of the machine through which the different components such as database nodes and storage cells. Infiniband is a hardware media running a protocol called RDP (Reliable Datagram Protocol), which has high bandwidth and low latency – making the transfer of data extremely fast. Disk Layout The disk layout needs some additional explanation because that’s where most of the activities occur. As I mentioned previously, the disks are attached to the storage cells and presented as logical units (LUNs), on which physical volumes are built. Each cell has 12 physical disks. In a high capacity configuration they are about 2TB and in a high performance configuration, they are about 600GB each. The disks are used for the database storage. Two of the 12 disks are also used for the home directory and other Linux operating system files. These two disks are divided into different partitions as shown in Figure 2 below.
Figure 2 Disk Layout The physical disks are divided into multiple partitions. Each partition is then presented as a LUN to the cell. Some LUNs are used to create a filesystem for the OS. The others are presented as storage to the cell. These are called cell disks. The cell disks are further divided as grid disks, ostensibly referencing the grid infrastructure the disks are used inside. These grid disks are used to build ASM Diskgroups, so they are used as ASM disks. An ASM diskgroup is made up of several ASM disks from multiple storage cells. If the diskgroup is built with normal or high redundancy (which is the usual case), the failure groups are placed in different cells. As a result, if one cell fails, the data is still available on other cells. Finally the database is built on these diskgroups. These diskgroups are created with the following attributes by default: Parameter
Description
Value
_._DIRVERSION
The minimum allowed version for directories
11.2.0.2.0
COMPATIBLE.ASM
The maximum ASM version whose features can use this diskgroup. For instance ASM Volume Management is available in 11.2 only. If this parameter is set to 11.1, then this diskgroup can’t be used for an ASM volume.
11.2.0.2.0
IDP.TYPE
Intelligent Data Placement, a feature of ASM that allows placing data in such a way that more frequently accessed data is located close to the periphery of the disk where the access is faster.
dynamic
CELL.SMART_SCAN_CAPABLE
Can this diskgroup be enabled for Exadata Storage TRUE Server’s Smart Scan Capability?
COMPATIBLE
The minimum version of the database that can be 11.2.0.2 created on this diskgroup. The far back you go back in version number, the more the message passing between RExadata Database MachineS and ASM instances causing performance issue. So, unless you plan to create a pre-11.2 database here (which you most likely do not plan on), leave it as it is.
AU Size
The size of Allocation Unit on this disk. The AU is the least addressable unit on the diskgroup.
On two of the 12 disks, the operating system, Oracle Exadata Storage Server software, and other OS related filesystems such as /home are located. They occupy about 29GB on a disk. For protection, this area is mirrored as RAID1 with on another disk. The filesystems are mounted on that RAID1 volume. However, this leaves two cell disks with less data than the other ten. If we create an ASM diskgroup on these 12 disks, it will have an imbalance on those two disks. Therefore, you (or whoever is doing the installation) should create another diskgroup with 29TB from the other 10 cell disks. This will create same sized ASM disks for other diskgroups. This “compensatory” diskgroup is usually named DBFS_DG. Since this diskgroup is built on the inner tracks of the disk, the performance is low compared to the outer tracks. Therefore instead of creating a database file here, you may want to use it for some other purpose such as ETL files. ETL files need a filesystem. You can create a database filesystem on this diskgroup – hence the name DBFS_DG. Of course, you can use it for anything you want, even for database files as well, especially for less accessed objects. Now that you know the components, look at the next section to get a detailed description of these components. Detailed Specifications As of this writing, the current (third) generation of Exadata Database Machine comes in two models (X2-2 and X2-8); various sizes (full rack, half rack, and quarter rack); and three classes of storage (high performance, high capacity SAS, and high capacity SATA). For detailed specifications, please see the configuration specs on the Oracle website: X2-2, X2-8, X2-2 Storage Server. Summary In this installment you learned what Exadata is, what different hardware and software components it is made of, what enables its fast performance, and what you should be managing. A summary is provided below. In the next installment, you will learn about command categories and initial commands. Term
Description
Cell Offloading
The ability of the storage cells to execute some part of the processing of a query, and in the process filter the unnecessary data at the storage level.
Smart Scan
The feature that allows the cells to search for data only in relevant cells; not all
iDB
Intelligent Database protocol that allows database nodes to pass along information on the query, e.g. the predicate. It enables Smart Scan.
Node
Also known as Database Node or Compute Node. This is where the database, ASM and clusterware are run. The clients connect to this. Runs Oracle Enterprise Linux.
Cell
Also known as Storage Cells, which run the Exadata Storage Server software. The disks for database are attached to this. Runs Oracle Enterprise Linux.
Smart Flash
Flash memory based storage to be used as a disk, or as a secondary cache for frequently accessed segments to reduce disk access.
> Back to Series TOC
Arup Nanda (
[email protected]) has been an Oracle DBA for more than 14 years, handling all aspects of database administration, from performance tuning to security and disaster recovery. He is an Oracle ACE Director and was Oracle Magazine's DBA of the Year in 2003.
Oracle Exadata Commands Reference
Part 2: Command Categories, Configuration, and Basic Commands by Arup Nanda
Learn different categories of commands and what to do after your new Exadata Database Machine is powered on. > Back to Series TOC (The purpose of this guide is educational; it is not intended to replace official Oracle-provided manuals or other documentation. The information in this guide is not validated by Oracle, is not supported by Oracle, and should only be used at your own risk.)
In Part 1, you learned about the composition of the Oracle Exadata Database Machine and its various components. Figure 1 shows the different components again and what types of commands are used in each.
•
• • •
Figure 1 Command categories Linux commands - Let’s start with the lowest-level component – the physical disk. The physical disk, as you learned from the previous installment, is the actual disk drive. It has to be partitioned to be used for ASM and regular filesystem. Normal disk management commands come here, e.g. fdisk. The storage cells are Linux servers; so all the regular Unix server administration tasks – shutdown, ps, etc., are relevant here. (For a refresher on Linux commands, you can check out my five-part series on advanced Linux commands.) CellCLI - Let’s move on the next stack in the software: the Exadata Storage Server. To manage this, Oracle provides a command line tool: CellCLI (Cell Command Line Interpreter). All the cell-related commands are entered through the CellCLI. DCLI - The scope of the CellCLI command is the cell where it is run, not in other cells. Sometimes you may want to execute a command across multiple cells from one command prompt, e.g. shutting down multiple nodes. There is another command line tool for that: DCLI. SQL – Once the cell disks are made available to the database nodes, the rest of the work is similar to what happens in a typical Oracle RAC database, in the language you use every day: SQL. SQL*Plus is an interface many DBAs use. You can also use other interfaces such as Oracle SQL Developer. If you
• • •
have Grid Control, there are lots of commands you don’t even need to remember; they will be GUI based. ASMCMD – ASMCMD this is the command line interface for managing ASM resources like diskgroups, backups, etc. SRVCTL – SRVTCL is a command-line interface to manage Oracle Database 11.2 RAC Clusters. At the database level, most of the commands related to cluster, e.g. starting/stopping cluster resources, checking for status, etc. can be done through this interface. CRSCTL – CRSCTL is another tool to manage clusters. As of 11.2, the need to use this tool has dwindled to near zero. But there is at least one command in this category.
These are the basic categories of the commands. Of these only CellCLI and DCLI are Exadata specific. The rest, especially SQL, should be very familiar to DBAs. Now that you know how narrow the scope of the commands is, do you feel a bit more relaxed? In the next sections we will see how these commands are used. (Note: Since CellCLI and DCLI are Exadata-specific commands, most DBAs making the transition to DMA are not expected to know about them. The next installment of the series – Part 3 –focuses on these two command categories exclusively.) Configuration Let’s start with the most exciting part: Your shiny new Exadata Database Machine is here, uncrated, mounted on the floorboards and connected to power. Now what? Fortunately, the machine comes pre-imaged with all the necessary OS, software and drivers. There is no reason to tinker with the software installation. In fact, it’s not only unnecessary but dangerous as well, since it may void the warranty. You should not install any software on storage cells at all, and only the following on the database servers themselves:
•
Grid Control Agent (required for management through Grid Control, explained in Part 4)
•
RMAN Media Management Library (to back up to tape)
•
Security Agent (if needed)
You are itching to push that button, aren’t you? But wait; before you start the configuration you have to have the following information handy:
•
Network – you should decide what names you will use for the servers, decide on IP addresses, have them in DNS, etc.
•
SMTP and SNMP information - for sending mails, alerts, etc.
•
Storage layout to address your specific requirements – for instance do you want Normal or High Redundancy, how many diskgroups do you want, what do you want to name them, etc.?
Once all these are done, here are the rough steps: 1.
Storage configuration
2.
OS configuration
3.
Creation of userids in Linux or Oracle Solaris
4.
ASM configuration
5.
Clusterware installation
6.
Database creation
Let’s examine the steps. Please note with several models, capacity classes, and types of hardware, it is not possible to provide details about all the possible combinations. Your specific environment may be unique as well.
The following section shows a sample configuration and should be followed as an illustration only. For simplicity, the OS covered here is Oracle Linux.
Configuration Worksheet Oracle provides a detailed configuration worksheet that allows you to enter specific details of your implementation and decide on exact configuration. This worksheet is found in Exadata storage server in the following directory : opt/oracle/cell/doc/doc The exact file you want to open is e16099.pdf, which has all the worksheets to guide you how to configure. Here is an excerpt from the worksheet:
Figure 2 Worksheet excerpt The configuration worksheet creates the following files in the directory /opt/oracle.SupportTools/onecommand. Here is a listing of that directory: # ls all_group cell_group config.dat patches all_ib_group cell_ib_group dbs_group priv_ib_group all_nodelist_group checkip.sh dbs_ib_group tmp These files are very important. Here is a brief description of each file: File Name
Description
all_group
List of database nodes and storage cells in this Exadata Database Machine. Here is an excerpt:
proldb01 proldb02 proldb03 proldb04 These are the database server nodes. all_ib_group
All host names of the private interconnects, both of cell servers and database nodes. Here is an excerpt from this file: proldb01-priv proldb02-priv proldb03-priv proldb04-priv proldb05-priv
all_nodelist_group
All host names – public, hosts, private interconnects – of both storage and database nodes. Here is an excerpt from this file: proldb07 proldb08 prolcel01 prolcel02 prolcel03
cell_group
Host names of all cell servers. Here is an excerpt from this file: prolcel01 prolcel02 prolcel03 prolcel04 prolcel05
cell_ib_group
Hostnames of private interconnects of all cell servers. Here is an excerpt from this file: prolcel01-priv prolcel02-priv prolcel03-priv prolcel04-priv prolcel05-priv
config.dat
The data file that is created from the configuration worksheet and is used to create the various scripts. Here is an excerpt from this file: customername=AcmeBank dbmprefix=prol cnbase=db cellbase=cel machinemodel=X2-2 Full rack dbnodecount=8 cellnodecount=14
dbs_group
Hostnames of the database nodes, similar to the cell servers. Here is an excerpt from the file: proldb01 proldb02 proldb03 proldb04
dbs_ib_group
Hostnames of private interconnects of the database nodes, similar to the cell servers. Here is an excerpt from the file: proldb01-priv proldb02-priv proldb03-priv proldb04-priv
priv_ib_group
All private interconnect hostnames and their corresponding IP addresses are listed in this file. This is used to populate /etc/hosts file. Here is an excerpt from the file: ### Compute Node Private Interface details 172.32.128.1 proldb01-priv.test.prol proldb01-priv 172.32.128.2 proldb02-priv.test.prol proldb02-priv 172.32.128.3 proldb03-priv.test.prol proldb03-priv 172.32.128.4 proldb04-priv.test.prol proldb04-priv
checkip.sh
This is a shell script to validate the accuracy of the network configuration. This is one of the most important files. The chckip script is called at multiple places with different parameters as you will see to perform validation at multiple places.
Hardware Profile The next thing to do is to check the hardware profile. Oracle provides a tool for that as well. This is the command you should use: # /opt/oracle.SupportTools/CheckHWnFWProfile The output should be: [SUCCESS] The hardware and firmware profile matches one of the supported profiles If you see something different here, the message should be self-explanatory. The right thing to do at this point is to call up Exadata installation support since some hardware/software combination is not as expected.
Physical Disks Next, you should check the disks to make sure they are up and online. Online does not mean they are available to ASM; it simply means the disks are visible to the server. To check the disks are visible and online, use this command: # /opt/MegaRAID/MegaCli/MegaCli64 Pdlist -aAll |grep "Slot \|Firmware" Here is truncated output: Slot Number: 0 Firmware state: Online, Spun Up Slot Number: 1 Firmware state: Online, Spun Up … Output truncated …
Slot Number: 11 Firmware state: Online, Spun Up If a disk is not online, you may want to replace it or at least understand the reason.
Flash Disks After checking physical disks you should check flash disks. The Linux command for that is lsscsi, shown below.
# lsscsi |grep -i marvel [1:0:0:0] disk ATA MARVELL SD88SA02 D20Y /dev/sdm [1:0:1:0] disk ATA MARVELL SD88SA02 D20Y /dev/sdn [1:0:2:0] disk ATA MARVELL SD88SA02 D20Y /dev/sdo [1:0:3:0] disk ATA MARVELL SD88SA02 D20Y /dev/sdp [2:0:0:0] disk ATA MARVELL SD88SA02 D20Y /dev/sdq [2:0:1:0] disk ATA MARVELL SD88SA02 D20Y /dev/sdr [2:0:2:0] disk ATA MARVELL SD88SA02 D20Y /dev/sds [2:0:3:0] disk ATA MARVELL SD88SA02 D20Y /dev/sdt [3:0:0:0] disk ATA MARVELL SD88SA02 D20Y /dev/sdu [3:0:1:0] disk ATA MARVELL SD88SA02 D20Y /dev/sdv [3:0:2:0] disk ATA MARVELL SD88SA02 D20Y /dev/sdw [3:0:3:0] disk ATA MARVELL SD88SA02 D20Y /dev/sdx [4:0:0:0] disk ATA MARVELL SD88SA02 D20Y /dev/sdy [4:0:1:0] disk ATA MARVELL SD88SA02 D20Y /dev/sdz [4:0:2:0] disk ATA MARVELL SD88SA02 D20Y /dev/sdaa [4:0:3:0] disk ATA MARVELL SD88SA02 D20Y /dev/sdab By the way, you can also check the flashdisks from the CellCLI tool as well. TheCellCLI tool is explainedin detail in the next installment in this series. #cellcli CellCLI: Release 11.2.2.2.0 - Production on Sun Mar 13 12:57:24 EDT 2011 Copyright (c) 2007, 2009, Oracle. All rights reserved. Cell Efficiency Ratio: 627M CellCLI> list lun where disktype=flashdisk 1_0 1_0 normal 1_1 1_1 normal 1_2 1_2 normal 1_3 1_3 normal 2_0 2_0 normal 2_1 2_1 normal 2_2 2_2 normal 2_3 2_3 normal 4_0 4_0 normal 4_1 4_1 normal 4_2 4_2 normal 4_3 4_3 normal 5_0 5_0 normal 5_1 5_1 normal 5_2 5_2 normal 5_3 5_3 normal To make sure the numbering of the flashdisks is correct, use the following command in CellCLI. Note that there is a hyphen (“-“) after the first line, since the command is too long to fit in one line and the “-“ is the continuation character. CellCLI> list physicaldisk attributes name, id, slotnumber > where disktype="flashdisk" and status != "not present" [1:0:0:0] 5080020000f21a2FMOD0 "PCI Slot: 4; FDOM: 0" [1:0:1:0] 5080020000f21a2FMOD1 "PCI Slot: 4; FDOM: 1"
[1:0:2:0] 5080020000f21a2FMOD2 "PCI Slot: 4; FDOM: 2" [1:0:3:0] 5080020000f21a2FMOD3 "PCI Slot: 4; FDOM: 3" [2:0:0:0] 5080020000f131aFMOD0 "PCI Slot: 1; FDOM: 0" [2:0:1:0] 5080020000f131aFMOD1 "PCI Slot: 1; FDOM: 1" [2:0:2:0] 5080020000f131aFMOD2 "PCI Slot: 1; FDOM: 2" [2:0:3:0] 5080020000f131aFMOD3 "PCI Slot: 1; FDOM: 3" [3:0:0:0] 5080020000f3ec2FMOD0 "PCI Slot: 5; FDOM: 0" [3:0:1:0] 5080020000f3ec2FMOD1 "PCI Slot: 5; FDOM: 1" [3:0:2:0] 5080020000f3ec2FMOD2 "PCI Slot: 5; FDOM: 2" [3:0:3:0] 5080020000f3ec2FMOD3 "PCI Slot: 5; FDOM: 3" [4:0:0:0] 5080020000f3e16FMOD0 "PCI Slot: 2; FDOM: 0" [4:0:1:0] 5080020000f3e16FMOD1 "PCI Slot: 2; FDOM: 1" [4:0:2:0] 5080020000f3e16FMOD2 "PCI Slot: 2; FDOM: 2" [4:0:3:0] 5080020000f3e16FMOD3 "PCI Slot: 2; FDOM: 3" Auto-configuration While it is possible to configure Exadata Database Machine manually, you don’t need to. In fact, you may not want to. Oracle provides three shell scripts for automatic configuration in the directory /opt/oracle.SupportTools/onecommand (these steps may change in later versions):
•
check_ip.sh – for checking the configuration at various stages
•
applyconfig.sh – to change the configuration
•
deploy112.sh – for final deployment
First, you should check the configuration for validity. To do that execute: # check_ip.sh -m pre_applyconfig Exadata Database Machine Network Verification version 1.9 Network verification mode pre_applyconfig starting ... Saving output file from previous run as dbm.out_17739 Using name server xx.xxx.59.21 found in dbm.dat for all DNS lookups Processing section DOMAIN : SUCCESS Processing section NAME : SUCCESS Processing section NTP : SUCCESS Processing section GATEWAY : SUCCESS Processing section SCAN : ERROR - see dbm.out for details Processing section COMPUTE : ERROR - see dbm.out for details Processing section CELL : ERROR - see dbm.out for details Processing section ILOM : ERROR - see dbm.out for details Processing section SWITCH : ERROR - see dbm.out for details Processing section VIP : ERROR - see dbm.out for details Processing section SMTP : SMTP "Email Server Settings" standardrelay.acmehotels.com 25:0 SUCCESS One or more checks report ERROR. Review dbm.out for details If you check the file dbm.out, you can see the exact error messages. Running in mode pre_applyconfig Using name server xx.xxx.59.21 found in dbm.dat for all DNS lookups Processing section DOMAIN test.prol Processing section NAME GOOD : xx.xxx.59.21 responds to resolve request for proldb01.test.prol GOOD : xx.xxx.59.22 responds to resolve request for proldb01.test.prol Processing section NTP GOOD : xx.xxx.192.1 responds to time server query (/usr/sbin/ntpdate -q)
Processing section GATEWAY GOOD : xx.xxx.192.1 pings successfully GOOD : xx.xxx.18.1 pings successfully Processing section SCAN GOOD : prol-scan.test.prol resolves to 3 IP addresses GOOD : prol-scan.test.prol forward resolves to xx.xxx.18.32 GOOD : xx.xxx.18.32 reverse resolves to prol-scan.test.prol. ERROR : xx.xxx.18.32 pings GOOD : prol-scan.test.prol forward resolves to xx.xxx.18.33 GOOD : xx.xxx.18.33 reverse resolves to prol-scan.test.prol. ERROR : xx.xxx.18.33 pings GOOD : prol-scan.test.prol forward resolves to xx.xxx.18.34 GOOD : xx.xxx.18.34 reverse resolves to prol-scan.test.prol. ERROR : xx.xxx.18.34 pings Processing section COMPUTE GOOD : proldb01.test.prol forward resolves to xx.xxx.192.16 GOOD : xx.xxx.192.16 reverse resolves to proldb01.test.prol. ERROR : xx.xxx.192.16 pings GOOD : proldb02.test.prol forward resolves to xx.xxx.192.17 GOOD : xx.xxx.192.17 reverse resolves to proldb02.test.prol. ERROR : xx.xxx.192.17 pings GOOD : proldb03.test.prol forward resolves to xx.xxx.192.18 GOOD : xx.xxx.192.18 reverse resolves to proldb03.test.prol. ERROR : xx.xxx.192.18 pings … output truncated … It will report all issues that must be addressed. After addressing all issues, execute the actual configuration: # applyconfig.sh After it completes, connect the Exadata Database Machine to your network and check for the validity: # check_ip.sh -m post_applyconfig It will report the output in the same manner as the pre_applyconfig parameter and will report any issue, if present. After fixing the issues, run the deployment script. That script actually executes several steps inside it – 29 in all. The most prudent thing to do is to first list out all the steps so that you can be familiar with them. The option l (that’s the letter “l”; not the numeral “1”) displays all the steps in the list. # deploy112.sh –l To run all the steps you should issue # deploy112.sh –i If you would prefer, you can run steps one by one, or groups at a time. To run steps 1 through 3, issue: # deploy112.sh –i -r 1-3 Or, to run only step 1: # deploy112.sh -i -s 1 The steps are listed here. (Please note: the steps can change without notice. The most up-to-date list will always be found in the release notes that come with an Exadata box.) Step
Description
0
Validate this server setup
1
Setup SSH for the root user.
2
Validate all nodes.
3
Unzip files.
4
Update the /etc/hosts directory.
5
Create the cellip.ora and cellinit.ora files
6
Validate the hardware.
7
Validate the InfiniBand network.
8
Validate the cells.
9
Check RDS using the ping command.
10
Run the CALIBRATE command.
11
Validate the time and date.
12
Update the configuration.
13
Create the user accounts for celladmin and cellmonitor.
14
Set up SSH for the user accounts.
15
Create the Oracle home directories.
16
Create the grid disks.
17
Install the grid software.
18
Run the grid root scripts.
19
Install the Oracle Database software.
20
Create the listener.
21
Run Oracle ASM configuration assistant to configure Oracle ASM.
22
Unlock the Oracle Grid Infrastructure home directory.
23
Relink Reliable Data Socket (RDS) protocol.
24
Lock Oracle Grid Infrastructure.
25
Set up e-mail alerts for Exadata Cells.
26
Run Oracle Database Configuration Assistant.
27
Set up Oracle Enterprise Manager Grid Control.
28
Apply any security fixes.
29
Secure Oracle Exadata Database Machine.
Here is the output of the script (amply truncated at places to conserve space): # ./deploy112.sh -i Script started, file is /opt/oracle.SupportTools/onecommand/tmp/STEP-0-proldb01-20110331154414.log =========== 0 ValidateThisNodeSetup Begin =============== Validating first boot... This step will validate DNS, NTS, params.sh, dbmachine.params, and all the files generated by the DB Machine Configurator In Check and Fix Hosts... INFO: This nslookup could take upto ten seconds to resolve if the host isn't in DNS, please wait.. INFO: Running /usr/bin/nslookup prol-scan... INFO: Running /usr/bin/nslookup proldb02... SUCCESS: SCAN and VIP found in DNS... Looking up nodes in dbmachine.params and dbs_group... SUCCESS: proldb01 has ip address of xx.xxx.192.16..A_OK SUCCESS: proldb02 has ip address of xx.xxx.192.17..A_OK … output truncated … SUCCESS: proldb08 has ip address of xx.xxx.192.23..A_OK SUCCESS: prol01-vip has ip address of xx.xxx.18.24..A_OK SUCCESS: Found IP Address xx.xxx.18.24 for prol01-vip using ping... SUCCESS: Based on bondeth0:xx.xxx.18.16 and NetMask:255.255.255.0 we picked bondeth0 as the appropriate VIP interface SUCCESS: prol02-vip has ip address of xx.xxx.18.25..A_OK SUCCESS: Found IP Address xx.xxx.18.24 for prol01-vip using ping... SUCCESS: Based on bondeth0:xx.xxx.18.16 and NetMask:255.255.255.0 we picked bondeth0 as the appropriate VIP interface … output truncated … SUCCESS: prol08-vip has ip address of xx.xxx.18.31..A_OK SUCCESS: Found IP Address xx.xxx.18.24 for prol01-vip using ping... SUCCESS: Based on bondeth0:xx.xxx.18.16 and NetMask:255.255.255.0 we picked bondeth0 as the appropriate VIP interface Checking blocksizes... SUCCESS: DB blocksize is 16384 checks out checking patches checking patches and version = 11202 SUCCESS: Located patch# 10252487 in /opt/oracle.SupportTools/onecommand/patches... INFO: Checking zip files INFO: Validating zip file /opt/oracle.SupportTools/onecommand/p10098816_112020_Linux-x8664_1of7.zip... Archive: Length
/opt/oracle.SupportTools/onecommand/p10098816_112020_Linux-x86-64_1of7.zip Date
Time
Name
--------
----
----
----
0
11-16-10 03:10
database/
0
11-16-10 03:03
database/install/
182
11-16-10 03:03
database/install/detachHome.sh
… output truncated … 41092
11-16-10 03:03
database/doc/install.112/e17212/concepts.htm
1892
11-16-10 03:03
database/doc/install.112/e17212/contents.js
44576
11-16-10 03:03
database/doc/install.112/e17212/crsunix.htm
ERROR: /usr/bin/unzip -l /opt/oracle.SupportTools/onecommand/p10098816_112020_Linux-x86-64_1of7.zip did not complete successfully: Return Status: 80 Step# 1 Exiting... Time spent in step 1
= 1 seconds
INFO: Going to run /opt/oracle.cellos/ipconf /opt/oracle.SupportTools/onecommand/preconf-11-2-1-22.csv -verify -ignoremismatch -verbose to validate first boot... INFO: Running /opt/oracle.cellos/ipconf -verify -ignoremismatch -verbose on this node... Verifying of configuration for /opt/oracle.cellos/cell.conf Config file exists
: PASSED
Load configuration
: PASSED
Config version defined
: PASSED
Config version 11.2.2.1.1 has valid value
: PASSED
Nameserver xx.xxx.59.21 has valid IP address syntax
: PASSED
Nameserver xx.xxx.59.22 has valid IP address syntax
: PASSED
Canonical hostname defined
: PASSED
Canonical hostname has valid syntax
: PASSED
Node type defined
: PASSED
Node type db is valid
: PASSED
This node type is db
: PASSED
Timezone defined
: PASSED
Timezone found in /usr/share/zoneinfo
: PASSED
NTP server xx.xxx.192.1 has valid syntax
: PASSED
NTP drift file defined
: PASSED
Network eth0 interface defined
: PASSED
IP address defined for eth0
: PASSED
IP address has valid syntax for eth0
: PASSED
Netmask defined for eth0
: PASSED
Netmask has valid syntax for eth0
: PASSED
Gateway has valid syntax for eth0
: PASSED
Gateway is inside network for eth0
: PASSED
Network type defined for eth0
: PASSED
Network type has proper value for eth0
: PASSED
Hostname defined for eth0
: PASSED
Hostname for eth0 has valid syntax
: PASSED
Network bondeth0 interface defined
: PASSED
IP address defined for bondeth0
: PASSED
IP address has valid syntax for bondeth0
: PASSED
Netmask defined for bondeth0
: PASSED
Netmask has valid syntax for bondeth0
: PASSED
Gateway has valid syntax for bondeth0
: PASSED
Gateway is inside network for bondeth0
: PASSED
Network type defined for bondeth0
: PASSED
Network type has proper value for bondeth0
: PASSED
Hostname defined for bondeth0
: PASSED
Hostname for bondeth0 has valid syntax
: PASSED
Slave interfaces for bondeth0 defined
: PASSED
Two slave interfaces for bondeth0 defined
: PASSED
Master interface ib0 defined
: PASSED
Master interface ib1 defined
: PASSED
Network bondib0 interface defined
: PASSED
IP address defined for bondib0
: PASSED
IP address has valid syntax for bondib0
: PASSED
Netmask defined for bondib0
: PASSED
Netmask has valid syntax for bondib0
: PASSED
Network type defined for bondib0
: PASSED
Network type has proper value for bondib0
: PASSED
Hostname defined for bondib0
: PASSED
Hostname for bondib0 has valid syntax
: PASSED
Slave interfaces for bondib0 defined
: PASSED
Two slave interfaces for bondib0 defined
: PASSED
At least 1 configured Eth or bond over Eth interface(s) defined
: PASSED
2 configured Infiniband interfaces defined
: PASSED
1 configured bond over ib interface(s) defined
: PASSED
ILOM hostname defined
: PASSED
ILOM hostname has valid syntax
: PASSED
ILOM short hostname defined
: PASSED
ILOM DNS search defined
: PASSED
ILOM full hostname matches short hostname and DNS search
: PASSED
ILOM IP address defined
: PASSED
ILOM IP address has valid syntax
: PASSED
ILOM Netmask defined
: PASSED
ILOM Netmask has valid syntax
: PASSED
ILOM Gateway has valid syntax
: PASSED
ILOM Gateway is inside network
: PASSED
ILOM nameserver has valid IP address syntax
: PASSED
ILOM use NTP servers defined
: PASSED
ILOM use NTP has valid syntax
: PASSED
ILOM first NTP server has non-empty value
: PASSED
ILOM first NTP server has valid syntax
: PASSED
ILOM timezone defined
: PASSED
Done. Config OK INFO: Printing group files.... ###################################################### This is the list of Database nodes... proldb01 … output truncated … proldb08 This is the list of Cell nodes... prolcel01 … output truncated … prolcel14 This is the list of Database Private node names... proldb01-priv … output truncated … proldb08-priv This is the list of Cell Private node names... prolcel01-priv … output truncated … prolcel14-priv This is the list all node names... proldb01 … output truncated … prolcel14 This is the list all private node names... proldb01-priv … output truncated … prolcel14-priv
This is the template /etc/hosts file for private nodes... ### Compute Node Private Interface details 172.32.128.1
proldb01-priv.test.prol proldb01-priv
… output truncated … 172.32.128.8
proldb08-priv.test.prol proldb08-priv
### CELL Node Private Interface details 172.32.128.9
prolcel01-priv.test.prol
prolcel01-priv
… output truncated … 172.32.128.22
prolcel14-priv.test.prol
prolcel14-priv
### Switch details # The following 5 IP addresses are for reference only. You may # not be able to reach these IP addresses from this machine # xx.xxx.192.60 prolsw-kvm.test.prol
prolsw-kvm
# xx.xxx.192.61 prolsw-ip.test.prol
prolsw-ip
# xx.xxx.192.62 prolsw-ib1.test.prol
prolsw-ib1
# xx.xxx.192.63 prolsw-ib2.test.prol
prolsw-ib2
# xx.xxx.192.64 prolsw-ib3.test.prol
prolsw-ib3
Creating work directories and validating
required files
ERROR: Please review and fix all ERROR's, we appear to have 1 errors... Exiting... Time spent in step 0 ValidateThisNodeSetup = 1 seconds Script done, file is /opt/oracle.SupportTools/onecommand/tmp/STEP-0-proldb01-20110331154414.log Check post-deployment configuration for IP addresses. # ./checkip.sh -m post_deploy112 Exadata Database Machine Network Verification version 1.9 Network verification mode post_deploy112 starting ... Saving output file from previous run as dbm.out_772 Using name server xx.xxx.59.21 found in dbm.dat for all DNS lookups Processing section DOMAIN
: SUCCESS
Processing section NAME
: SUCCESS
Processing section NTP
: SUCCESS
Processing section GATEWAY : SUCCESS Processing section SCAN
: SUCCESS
Processing section COMPUTE : SUCCESS Processing section CELL
: SUCCESS
Processing section ILOM
: SUCCESS
Processing section SWITCH
: SUCCESS
Processing section VIP
: SUCCESS
Processing section SMTP
: SMTP "Email Server Settings" standardrelay.acmehotels.com 25:0
SUCCESS
If everything should come back OK, your installation and configuration was successful. Basic Commands
Power Let’s start by understanding some very first commands you will need: powering on and off. The command for that is IPMITOOL. To power on a cell or database server, issue this from another server:
# ipmitool -H prolcel01-ilom -U root chassis power on IPMI – short for Intelligent Platform Management Interface - is an interface standard that allows remote management of a server from another using standardized interface. The servers in the Exadata Database Machine follow that. It’s not an Exadata command but rather a general Linux one. To get all the options available, execute: # ipmitool –h
To stop a server, use the shutdown command. To stop immediately and keep it down, i.e. not reboot, execute: # shutdown -h -y now To shut down after 10 minutes (the users will get a warning message) # shutdown -h -y 10 To reboot the server (the “-r” option is for reboot) # shutdown –r –y now Or, a simple: # reboot Sometimes you may want to shutdown multiple servers. The DCLI command comes handy that time. To shut down all the cells, execute the command: # dcli -l root -g all_cells shutdown -h -y now The –g option allows you to give a filename containing all the cell servers. For instance all_cells is a file as shown below: # cat all_cells prolcel01 prolcel02 prolcel03 prolcel04 prolcel05 prolcel06 prolcel07 prolcel08 You could use a similar file for all database servers and name it all_nodes. To shutdown all database servers: # dcli -l root -g all_nodes shutdown -h -y now You will learn the DCLI command in detail in the next installment.
Maintenance From time to time you will need to maintain the servers. (Remember, you are the DMA now, not the DBA.) One of the most common tasks is to install new software Images. Let’s see some of the related commands. To learn what software image is installed, use the following: # imageinfo Kernel version: 2.6.18-194.3.1.0.3.el5 #1 SMP Tue Aug 31 22:41:13 EDT 2010 x86_64 Cell version: OSS_11.2.0.3.0_LINUX.X64_101206.2 Cell rpm version: cell-11.2.2.2.0_LINUX.X64_101206.2-1 Active image version: 11.2.2.2.0.101206.2 Active image activated: 2011-01-21 14:09:21 -0800 Active image status: success Active system partition on device: /dev/md5 Active software partition on device: /dev/md7 In partition rollback: Impossible Cell boot usb partition: /dev/sdac1 Cell boot usb version: 11.2.2.2.0.101206.2 Inactive image version: undefined Rollback to the inactive partitions: Impossible You can glean some important information from the output above. Note the line Active image version: 11.2.2.2.0.101206.2, which indicates the specific Exadata Storage Server version. It also shows the date and time the software image was activated, which can be used to troubleshoot. If you see problems occurring from a specific date and time, you may be able to correlate.
On the heels of the above, the next logical question could be, if a new image was installed (activated), what was the version before this. To find out the history of all the image changes, you can use the imagehistory command. # imagehistory Version : 11.2.2.2.0.101206.2 Image activation date : 2011-01-21 14:09:21 -0800 Imaging mode : fresh Imaging status : success This is a fresh install, so you don’t see much of history. Managing Infiniband For the newly minted DMA nothing is as rattling as the networking commands. It’s like being given a stick-shift car when all you have ever driven is an automatic. As DBAs you probably didn’t have to execute anything other than ifconfig and netstat. Well, they still apply; so don’t forget that. But let’s see how to extend that knowledge to infiniband.
Status To get the status of the Infiniband services. First to check the status of the infiniband devices, use the ibstatus command. # ibstatus Infiniband device 'mlx4_0' port 1 status: default gid: fe80:0000:0000:0000:0021:2800:01a0:fd45 base lid: 0x1a sm lid: 0xc state: 4: ACTIVE phys state: 5: LinkUp rate: 40 Gb/sec (4X QDR) Infiniband device 'mlx4_0' port 2 status: default gid: fe80:0000:0000:0000:0021:2800:01a0:fd46 base lid: 0x1c sm lid: 0xc state: 4: ACTIVE phys state: 5: LinkUp rate: 40 Gb/sec (4X QDR) … output truncated … If it comes out OK, the next step is to check the status of the Infiniband Link, using the iblinkinfo. Here is a truncated output to save space. # iblinkinfo Switch 0x0021286cd6ffa0a0 Sun DCS 36 QDR switch prolsw-ib1.test.prol: 1
1[
] ==( 4X 2.5 Gbps
Down/Disabled)==>
[
] "" ( )
1
2[
] ==( 4X 2.5 Gbps
Down/Disabled)==>
[
] "" ( )
… output truncated … 1
17[
] ==( 4X 2.5 Gbps
Down/Disabled)==>
[
] "" ( )
1
18[
] ==( 4X 2.5 Gbps
Down/Disabled)==>
[
] "" ( )
1
19[
] ==( 4X xx.0 Gbps Active/
1
20[
] ==( 4X 2.5 Gbps
1
21[
] ==( 4X xx.0 Gbps Active/
LinkUp)==>
12
32[
11
32[
] "Sun DCS 36 QDR switch
localhost" ( ) Down/Disabled)==> LinkUp)==>
[
] "" ( ) ] "Sun DCS 36 QDR switch
prolsw-ib2.test.prol" ( ) … output truncated … 1
36[
] ==( 4X 2.5 Gbps
Down/Disabled)==>
[
] "" ( )
Switch 0x0021286cd6eba0a0 Sun DCS 36 QDR switch localhost: 12
1[
] ==( 4X xx.0 Gbps Active/
LinkUp)==>
43
2[
] "prolcel02 C
172.32.128.10 HCA-1" ( ) … output truncated … 12
11[
] ==( 4X 2.5 Gbps
12
12[
] ==( 4X xx.0 Gbps Active/
Down/Disabled)==>
[
LinkUp)==>
17
2[
LinkUp)==>
11
17[
LinkUp)==>
20
1[
] "" ( ) ] "proldb04 S 172.32.128.4
HCA-1" ( ) … output truncated … 12
18[
] ==( 4X xx.0 Gbps Active/
] "Sun DCS 36 QDR switch
prolsw-ib2.test.prol" ( ) 12
19[
] ==( 4X xx.0 Gbps Active/
] "prolcel13 C
172.32.128.21 HCA-1" ( ) … output truncated … 12
29[
] ==( 4X 2.5 Gbps
12
30[
] ==( 4X xx.0 Gbps Active/
Down/Disabled)==> LinkUp)==>
6
[ 1[
] "" ( )
31[
] ==( 4X xx.0 Gbps Active/
LinkUp)==>
11
31[
] "Sun DCS 36 QDR switch
LinkUp)==>
1
19[
] "Sun DCS 36 QDR switch
] "proldb05 S 172.32.128.5
HCA-1" ( ) 12
prolsw-ib2.test.prol" ( ) 12
32[
] ==( 4X xx.0 Gbps Active/
prolsw-ib1.test.prol" ( ) 12
33[
] ==( 4X 2.5 Gbps
Down/Disabled)==>
[
] "" ( )
Down/Disabled)==>
[
] "" ( )
… output truncated … 12
36[
] ==( 4X 2.5 Gbps
Switch 0x0021286ccc72a0a0 Sun DCS 36 QDR switch prolsw-ib2.test.prol: 11
1[
] ==( 4X xx.0 Gbps Active/
LinkUp)==>
42
1[
] "prolcel02 C
LinkUp)==>
14
1[
] "proldb02 S 172.32.128.2
172.32.128.10 HCA-1" ( ) … output truncated … 11
10[
] ==( 4X xx.0 Gbps Active/
11[
] ==( 4X 2.5 Gbps
HCA-1" ( ) 11
Down/Disabled)==>
[
] "" ( )
… output truncated … 11
28[
] ==( 4X xx.0 Gbps Active/
LinkUp)==>
3
2[
] "proldb07 S 172.32.128.7
11
29[
] ==( 4X 2.5 Gbps
11
30[
] ==( 4X xx.0 Gbps Active/
LinkUp)==>
7
2[
31[
] ==( 4X xx.0 Gbps Active/
LinkUp)==>
12
31[
] "Sun DCS 36 QDR switch
32[
] ==( 4X xx.0 Gbps Active/
LinkUp)==>
1
21[
] "Sun DCS 36 QDR switch
HCA-1" ( ) Down/Disabled)==>
[
] "" ( ) ] "proldb05 S 172.32.128.5
HCA-1" ( ) 11 localhost" ( ) 11
prolsw-ib1.test.prol" ( ) 11
33[
] ==( 4X 2.5 Gbps
Down/Disabled)==>
[
] "" ( )
11
34[
] ==( 4X 2.5 Gbps
Down/Disabled)==>
[
] "" ( )
11
35[
] ==( 4X 2.5 Gbps
Down/Disabled)==>
[
] "" ( )
11
36[
] ==( 4X 2.5 Gbps
Down/Disabled)==>
[
] "" ( )
Topology To get the topology of the infiniband network inside Exadata, use an Oracle supplied tool verify-topology, available in the directory /opt/oracle.SupportTools/ibdiagtools # ./verify-topology. [ DB Machine Infiniband Cabling Topology Verification Tool ] [Version 11.2.1.3.b] Looking at 1 rack(s)..... Spine switch check: Are any Exadata nodes connected ..............[SUCCESS] Spine switch check: Any inter spine switch connections............[SUCCESS] Spine switch check: Correct number of spine-leaf links............[SUCCESS] Leaf switch check: Inter-leaf link check..........................[SUCCESS] Leaf switch check: Correct number of leaf-spine connections.......[SUCCESS] Check if all hosts have 2 CAs to different switches...............[SUCCESS] Leaf switch check: cardinality and even distribution..............[SUCCESS] Cluster Operations
To manage the Oracle Clusterware you use the same commands as you would in a traditional Oracle 11g Release 2 RAC database cluster. The commands are:
•
CRSCTL – for a few cluster related commands
•
SRVCTL – for most cluster related commands
CRSCTL is not used much but you need it for some occasions – mostly to shut down the cluster and to start up (if is not started automatically during the machine startup). Remember, you have to be root to issue this command. However, the root user may not have the location of this tool in its path. So, you should use its fully qualified patch while issuing the command. Here is the command to stop the cluster on all nodes: # /bin/crsctl stop cluster –all You don’t need to shutdown the cluster on all nodes; sometimes all you need is to shut down the cluster on only one node. To shut down the cluster on one node alone, use: # /bin/crsctl stop cluster –n Similarly to start the cluster on one of the nodes where the cluster was initially stopped, # /bin/crsctl start cluster –n Finally, you may want to make sure all the cluster resources are running. Here is the command for that. The status command does not need to be issued by root. # /bin/crsctl status resource –t -------------------------------------------------------------------------------NAME
TARGET
STATE
SERVER
STATE_DETAILS
-------------------------------------------------------------------------------Local Resources -------------------------------------------------------------------------------ora.DBFS_DG.dg ONLINE
ONLINE
proldb01
ONLINE
ONLINE
proldb02
ONLINE
ONLINE
proldb03
ONLINE
ONLINE
proldb04
ONLINE
ONLINE
proldb05
ONLINE
ONLINE
proldb06
ONLINE
ONLINE
proldb07
ONLINE
ONLINE
proldb08
ONLINE
ONLINE
proldb01
ONLINE
ONLINE
proldb02
ONLINE
ONLINE
proldb03
ONLINE
ONLINE
proldb04
ONLINE
ONLINE
proldb05
ONLINE
ONLINE
proldb06
ONLINE
ONLINE
proldb07
ONLINE
ONLINE
proldb08
ONLINE
ONLINE
proldb01
ONLINE
ONLINE
proldb02
ONLINE
ONLINE
proldb03
ONLINE
ONLINE
proldb04
ONLINE
ONLINE
proldb05
ONLINE
ONLINE
proldb06
ONLINE
ONLINE
proldb07
ONLINE
ONLINE
proldb08
ONLINE
proldb01
ora.PRODATA.dg
ora.PRORECO.dg
ora.LISTENER.lsnr ONLINE
ONLINE
ONLINE
proldb02
ONLINE
ONLINE
proldb03
ONLINE
ONLINE
proldb04
ONLINE
ONLINE
proldb05
ONLINE
ONLINE
proldb06
ONLINE
ONLINE
proldb07
ONLINE
ONLINE
proldb08
ONLINE
ONLINE
proldb01
Started
ONLINE
ONLINE
proldb02
Started
ONLINE
ONLINE
proldb03
Started
ONLINE
ONLINE
proldb04
Started
ONLINE
ONLINE
proldb05
Started
ONLINE
ONLINE
proldb06
Started
ONLINE
ONLINE
proldb07
Started
ONLINE
ONLINE
proldb08
ora.asm
ora.gsd OFFLINE OFFLINE
proldb01
OFFLINE OFFLINE
proldb02
OFFLINE OFFLINE
proldb03
OFFLINE OFFLINE
proldb04
OFFLINE OFFLINE
proldb05
OFFLINE OFFLINE
proldb06
OFFLINE OFFLINE
proldb07
OFFLINE OFFLINE
proldb08
ora.net1.network ONLINE
ONLINE
proldb01
ONLINE
ONLINE
proldb02
ONLINE
ONLINE
proldb03
ONLINE
ONLINE
proldb04
ONLINE
ONLINE
proldb05
ONLINE
ONLINE
proldb06
ONLINE
ONLINE
proldb07
ONLINE
ONLINE
proldb08
ONLINE
ONLINE
proldb01
ONLINE
ONLINE
proldb02
ONLINE
ONLINE
proldb03
ONLINE
ONLINE
proldb04
ONLINE
ONLINE
proldb05
ONLINE
ONLINE
proldb06
ONLINE
ONLINE
proldb07
ONLINE
ONLINE
proldb08
ONLINE
ONLINE
proldb01
ONLINE
ONLINE
proldb02
ONLINE
ONLINE
proldb03
ONLINE
ONLINE
proldb04
ONLINE
ONLINE
proldb05
ONLINE
ONLINE
proldb06
ONLINE
ONLINE
proldb07
ONLINE
ONLINE
proldb08
ora.ons
ora.registry.acfs
-------------------------------------------------------------------------------Cluster Resources -------------------------------------------------------------------------------ora.LISTENER_SCAN1.lsnr 1
ONLINE
ONLINE
ora.LISTENER_SCAN2.lsnr
proldb07
1
ONLINE
ONLINE
proldb02
ora.LISTENER_SCAN3.lsnr 1
ONLINE
ONLINE
proldb05
ONLINE
ONLINE
proldb02
ONLINE
proldb01
ONLINE
proldb02
ONLINE
proldb03
ONLINE
proldb04
ONLINE
proldb05
ONLINE
proldb06
ONLINE
proldb07
ONLINE
ONLINE
proldb08
1
ONLINE
ONLINE
proldb01
Open
2
ONLINE
ONLINE
proldb02
Open
3
ONLINE
ONLINE
proldb03
Open
4
ONLINE
ONLINE
proldb04
Open
5
ONLINE
ONLINE
proldb05
Open
6
ONLINE
ONLINE
proldb06
Open
7
ONLINE
ONLINE
proldb07
Open
8
ONLINE
ONLINE
proldb08
Open
ONLINE
ONLINE
proldb01
ONLINE
ONLINE
proldb07
ONLINE
ONLINE
proldb02
ONLINE
ONLINE
proldb05
ora.cvu 1
ora.proldb01.vip 1
ONLINE
ora.proldb02.vip 1
ONLINE
ora.proldb03.vip 1
ONLINE
ora.proldb04.vip 1
ONLINE
ora.proldb05.vip 1
ONLINE
ora.proldb06.vip 1
ONLINE
ora.proldb07.vip 1
ONLINE
ora.proldb08.vip 1 ora.prolrd.db
ora.oc4j 1 ora.scan1.vip 1 ora.scan2.vip 1 ora.scan3.vip 1
This output shows clearly the status of the various resources. A complete explanation of all the options of CRSCTL is not possible to give. Here is an abbreviated list of the options. To know the exact parameters required for each resource, simply call it with -h option. For instance, to know about the backup option, execute # crsctl backup -h Usage: crsctl backup css votedisk Backup the voting disk. Here is the list of the options for CRSCTL: crsctl add crsctl crsctl crsctl crsctl crsctl crsctl
backup check config debug delete disable
- add a resource, type or other entity - back up voting disk for CSS - check a service, resource or other entity - output autostart configuration - obtain or modify debug state - delete a resource, type or other entity - disable autostart
crsctl discover - discover DHCP server crsctl enable - enable autostart crsctl get - get an entity value crsctl getperm - get entity permissions crsctl lsmodules - list debug modules crsctl modify - modify a resource, type or other entity crsctl query - query service state crsctl pin - Pin the nodes in the nodelist crsctl relocate - relocate a resource, server or other entity crsctl replace - replaces the location of voting files crsctl release - release a DHCP lease crsctl request - request a DHCP lease crsctl setperm - set entity permissions crsctl set - set an entity value crsctl start - start a resource, server or other entity crsctl status - get status of a resource or other entity crsctl stop - stop a resource, server or other entity crsctl unpin - unpin the nodes in the nodelist crsctl unset - unset a entity value, restoring its default Another command SRVCTL performs most of the server-based operations including resource (such as service) relocation. This is nothing different from the tool on a traditional Oracle RAC 11g Release 2 Cluster. To know more about the options in this tool, execute this command: # srvctl -h Usage: srvctl [-V] Usage: srvctl add database -d -o [-c {RACONENODE | RAC | SINGLE} [-e ] [-i ] [-w ]] [-m ] [-p ] [-r {PRIMARY | PHYSICAL_STANDBY | LOGICAL_STANDBY | SNAPSHOT_STANDBY}] [-s ] [-t ] [-n ] [-y {AUTOMATIC | MANUAL}] [-g ""] [-x ] [-a ""] [-j ""] Usage: srvctl config database [-d [-a] ] [-v] Usage: srvctl start database -d [-o ] [-n ] Usage: srvctl stop database -d [-o ] [-f] Usage: srvctl status database -d [-f] [-v] … output truncated …
IPMI Tool Earlier in this article you saw a reference to the IPMI tool. We used it to power the servers on. But that is not the only thing you can do with this tool; there are plenty more options. If you want to find out what options are available, issue the command without any arguments. # ipmitool No command provided! Commands: raw i2c spd lan chassis power event mc sdr sensor fru sel pef sol
Send a RAW IPMI request and print response Send an I2C Master Write-Read command and print response Print SPD info from remote I2C device Configure LAN Channels Get chassis status and set power state Shortcut to chassis power commands Send pre-defined events to MC Management Controller status and global enables Print Sensor Data Repository entries and readings Print detailed sensor information Print built-in FRU and scan SDR for FRU locators Print System Event Log (SEL) Configure Platform Event Filtering (PEF) Configure and connect IPMIv2.0 Serial-over-LAN
tsol Configure and connect with Tyan IPMIv1.5 Serial-over-LAN isol Configure IPMIv1.5 Serial-over-LAN user Configure Management Controller users channel Configure Management Controller channels session Print session information sunoem OEM Commands for Sun servers kontronoem OEM Commands for Kontron devices picmg Run a PICMG/ATCA extended cmd fwum Update IPMC using Kontron OEM Firmware Update Manager firewall Configure Firmware Firewall shell Launch interactive IPMI shell exec Run list of commands from file set Set runtime variable for shell and exec hpm Update HPM components using PICMG HPM.1 file It’s not possible to explain each option here. Let’s examine one of the most used ones. The option sel shows System Event Log, one of the key commands you will need to use. # ipmitool sel SEL Information Version : 2.0 (v1.5, v2 compliant) Entries : 96 Free Space : 14634 bytes Percent Used : 9% Last Add Time : 02/27/2011 20:23:44 Last Del Time : Not Available Overflow : false Supported Cmds : 'Reserve' 'Get Alloc Info' # of Alloc Units : 909 Alloc Unit Size : 18 # Free Units : 813 Largest Free Blk : 813 Max Record Size : 18 The output is summary only. To know the details of the Event Log, you can use an additional parameter: list. # ipmitool sel list 1 | 01/21/2011 | 07:05:39 Asserted 2 | 01/21/2011 | 08:59:43 3 | 01/21/2011 | 08:59:44 4 | 01/21/2011 | 08:59:44 Asserted 5 | 01/21/2011 | 08:59:44 Asserted 6 | 01/21/2011 | 08:59:44 initialization | Asserted 7 | 01/21/2011 | 08:59:49 8 | 01/21/2011 | 08:59:52 9 | 01/21/2011 | 08:59:53 Asserted a | 01/21/2011 | 08:59:53 Asserted b | 01/21/2011 | 08:59:53 initialization | Asserted c | 01/21/2011 | 08:59:54 Asserted d | 01/21/2011 | 08:59:55 Asserted e | 01/21/2011 | 08:59:55
| System ACPI Power State #0x26 | S5/G2: soft-off | | System Boot Initiated | System Restart | Asserted | Entity Presence #0x54 | Device Present | System Boot Initiated | Initiated by hard reset | | System Firmware Progress | Memory initialization | | System Firmware Progress | Primary CPU | Entity Presence #0x58 | Device Present | Entity Presence #0x57 | Device Present | System Boot Initiated | Initiated by warm reset | | System Firmware Progress | Memory initialization | | System Firmware Progress | Primary CPU | System Boot Initiated | Initiated by warm reset | | System Firmware Progress | Memory initialization | | System Firmware Progress | Primary CPU
initialization | Asserted f | 01/21/2011 | 09:00:01 | Entity Presence #0x55 | Device Present ... truncated ... The output has been shown partially to conserve space. This is one of the key commands you should be aware of. In a troubleshooting episode, you should check the system even log to make sure the components have not failed. If they did, of course, you would have to replace them before going further. If you get a clean bill of health from IPMITOOL, you should go to the next step of making sure you have no issues with the cluster, then no issues with the RAC database and so on. ASMCMD Tool You can manage the ASM instance in three different ways:
•
SQL – traditional SQL commands are enough for ASM but may not be the best for scripting and quick checks such as checking for free space
•
ASMCMD – a command line tool for the ASM operations. It’s very user-friendly, especially for the SysAdmin-turned-DMA since it does not need knowledge of SQL
•
ASMCA – ASM Configuration Assistant; has limited functionality
Of these, ASMCMD is the most widely used. Let’s see how it works. You invoke the tool by executing asmcmd at the linux command prompt. $ asmcmd –p The -p parameter merely shows the current directory in the prompt. At the ASMCMD prompt, you can enter the commands. To now the free space in diskgroups, you issue the lsdg command. ASMCMD [+PRORECO] > lsdg State
Type
Rebal
Offline_disks MOUNTED
NORMAL
N
1896475 MOUNTED
Sector
Voting_files
512 0
NORMAL
N
512
29400845 MOUNTED 5850296
Block
AU
Total_MB
Free_MB
Req_mir_free_MB
4096
4194304
4175360
4172528
379578
N
DBFS_DG/
4096
4194304
67436544
64932284
6130594
23374656
21800824
4249936
0 HIGH
N
Usable_file_MB
Name
N 512
0
PRODATA/
4096
4194304
Y
PRORECO/
The command such as ls and cd works just like their namesakes in the Linux world. ASMCMD [+] > ls DBFS_DG/ PRODATA/ PRORECO/ ASMCMD [+] > cd PRORECO To know the space consumed by each file, you issue ls –ls command. ASMCMD [+PRORECO/PROLRD/ONLINELOG] > ls -ls Type Redund Striped Time Bytes Space Name ONLINELOG HIGH COARSE MAR 31 19:00:00 12910067712 group_1.257.744724579 ONLINELOG HIGH COARSE MAR 31 19:00:00 12910067712 group_xx.277.744725199 ONLINELOG HIGH COARSE MAR 31 19:00:00 12910067712 group_11.278.744725207 ONLINELOG HIGH COARSE MAR 31 19:00:00 12910067712 group_12.279.744725215 ONLINELOG HIGH COARSE MAR 31 19:00:00 12910067712 group_13.270.744725161
Sys
Block_Size
Blocks
Y
512
8388609
4294967808
Y
512
8388609
4294967808
Y
512
8388609
4294967808
Y
512
8388609
4294967808
Y
512
8388609
4294967808
ONLINELOG HIGH COARSE MAR 31 19:00:00 Y 12910067712 group_14.272.744725169 … output truncated … To get a complete listing of all the ASMCMD commands, use help.
512
8388609
4294967808
ASMCMD [+] > help commands: -------md_backup, md_restore lsattr, setattr cd, cp, du, find, help, ls, lsct, lsdg, lsof, mkalias mkdir, pwd, rm, rmalias chdg, chkdg, dropdg, iostat, lsdsk, lsod, mkdg, mount offline, online, rebal, remap, umount dsget, dsset, lsop, shutdown, spbackup, spcopy, spget spmove, spset, startup chtmpl, lstmpl, mktmpl, rmtmpl chgrp, chmod, chown, groups, grpmod, lsgrp, lspwusr, lsusr mkgrp, mkusr, orapwusr, passwd, rmgrp, rmusr volcreate, voldelete, voldisable, volenable, volinfo volresize, volset, volstat To get help about a specific command, use help ASMCMD [+] > help chkdg. chkdg Checks or repairs the metadata of a disk group. chkdg [--repair] diskgroup The options for the chkdg command are described below. --repair - Repairs the disk group. diskgroup - Name of disk group to check or repair. chkdg checks the metadata of a disk group for errors and optionally repairs the errors. The following is an example of the chkdg command used to check and repair the DATA disk group. ASMCMD [+] > chkdg --repair data
Task(s)
Command Category
Manage the operating system and servers – nodes as well as cells
Linux Commands such as shutdown fdisk, etc.
Power off and check status of components
IPMITOOL (Linux Tool)
Manage the Exadata Storage Server and cell related command
CellCLI Tool
Manage multiple cells at one time
DCLI
Manage ASM resources like diskgroup
SQL commands (can be SQL*Plus) or ASMCMD
Manage Clusterware
CRSCTL
Manage cluster components
SRVCTL
Manage the database
SQL commands (can be SQL*Plus)
Next Steps Now that you know the different categories of commands, you should know about the specific ones. In the next installment, will exclusively explore the commands in these two categories to complete your transition to a DMA. > Back to Series TOC
Arup Nanda (
[email protected]) has been an Oracle DBA for more than 14 years, handling all aspects of database administration, from performance tuning to security and disaster recovery. He is an Oracle ACE Director and was Oracle Magazine's DBA of the Year in 2003.
Oracle Exadata Commands Reference
Part 3: Storage Management by Arup Nanda A detailed explanation of the CellCLI and DCLI commands, all their parameters and options, and how they are used for managing storage cells > Back to Series TOC (The purpose of this guide is educational: to jump-start the transition from DBA to DMA and serve as a quick reference for practicing DMAs. It is not intended to replace official Oracle-provided manuals or other documentation. The information in this guide is not validated by Oracle, is not supported by Oracle, and should only be used at your own risk.)
In the previous two installments, you learned how the Oracle Exadata Database Machine works, about its various components, and the categories of commands applicable to each of those components. One such component is the storage cells, which manage the disks. For many DBAs transitioning into the role of DMAs, perhaps the biggest challenge is becoming comfortable with storage operations, something many DBAs never had to address. The storage cells in Exadata Database Machine are managed via two tools called CellCLI and DCLI. You had a glimpse of the CellCLI commands in action in Part 2, when configuring Exadata for the first time. In this installment, you will learn the detailed commands of these tools. In doing so, hopefully you will appreciate that it is not as difficult as you thought it would be. Basics The cellcli command is invoked from the Linux command line in the storage cells, not in the compute nodes. Similar to SQL*Plus showing SQL> prompt, CellCLI show the CellCLI> prompt where you will enter the commands. # cellcli CellCLI: Release 11.2.2.2.0 - Production on Fri Apr 01 10:39:58 EDT 2011 Copyright (c) 2007, 2009, Oracle. All rights reserved. Cell Efficiency Ratio: 372M This will display the CellCLI prompt where you are expected to enter the commands. CellCLI> … enter your commands here …
HELP The first command you may want to enter is know about all the other commands available. Well, get some help: CellCLI> help HELP [topic] Available Topics:
ALTER ALTER ALERTHISTORY ALTER CELL … output truncated … If you want to get more context sensitive help on a specific command, CellCLI> help list By the way, you don’t need to be in the CellCLI command prompt to give a command. If you know the command you want to give, you call it directly from Linux command prompt with the -e option. # cellcli -e help Or, you can use the typical Linux type command terminators, as shown below: [celladmin@prolcel14 ~]# cellcli list cell > EOF CellCLI: Release 11.2.2.2.2 - Production on Sat May 14 16:28:43 EDT 2011 Copyright (c) 2007, 2009, Oracle. All rights reserved. Cell Efficiency Ratio: 160M CellCLI> list cell prolcel14 online [celladmin@prolcel14 ~]# To exit from CellCLI, use the commands exit or quit.
Recording the Output Like SQL*Plus, CellCLI also has a spool command that records the output to a file. Here is an example where you want to record the output to a file named mycellcli.txt CellCLI> spool mycellcli.txt To append to a file you already have, use append CellCLI> spool mycellcli.txt append Or, if you want to overwrite the file, use replace CellCLI> spool mycellcli.txt replace To stop spooling, just issue SPOOL OFF. What if you want to know what file the output is being written to? Use SPOOL without any argument. It will show the name of the file. CellCLI> spool currently spooling to mycellcli.txt
Continuation Character You will learn later in the article that you can issue complex queries in CellCLI. Some of these queries might span multiple lines. Since there is no command terminator like “;” in SQL, ending a line makes CellCLI to start interpreting it immediately. To make sure CellCLI understands the line extends beyond the current line, you can use the continuation character “-“, just as you would have done in SQL*Plus. CellCLI> spool > mycellcli.txt Note the continuation prompt “>” above. However, unlike SQL*Plus, CellCLI does not show line numbers for the continued lines.
Scripting When you want to execute a standard command in CellCLI, you can create a script file with the commands and execute it using STARTor @ commands. For instance, to execute a script called listdisks.cli, you would issue one of the following:
CellCLI> @listdisks.cli CellCLI> start listdisks.cli Note that the there is no restriction on the extension. I used cli merely as a convenience, it could have been anything else. You can also use the routine Linux redirection command. Here is an example where you put all the commands in the file mycellci.commands and you want to spool the results to mycellci.out. This is good for automatic monitoring systems. # cellcli mycellci.out
Comments You can put comments in scripts as well. Comments start with REM, REMARK or "--", as shown below: REM This is a comment REMARK This is another comment -- This is yet another comment list physicaldisk
Environment You can define two environmental settings
•
dateformat – to show the format of the date when it is displayed. CellCLI> set dateformat local Date format was set: Apr 1, 2011 3:35:17 PM. CellCLI> set dateformat standard Date format was set: 2011-04-01T15:35:30-04:00.
•
echo – to toggle the display of commands within scripts. CellCLI> set echo on CellCLI> set echo off
I am sure you can find resemblance of the control commands with SQL*Plus, a tool you are undoubtedly familiar with. The learning curve should not be tat difficult. Now that you know about the basic commands, let’s dive down to more advanced ones. General Structure The CellCLI commands have the following general structure:
•
A verb is what you want or the action, e.g. display something.
•
An object is what you want the action on, e.g. a disk.
•
A modifier (optional) shows how you want to operation to be modified, e.g. all disks, or a specific disk, etc.
•
A filter (optional) is similar to the WHERE predicate of a SQL statement, used with WHERE clause.
There are only a few primary verbs you will use mostly and need to remember. They are:
•
LIST – to show something, e.g. disks, statistics, Resource Manager Plans, etc.
•
CREATE – to create something, e.g. a cell disk, a threshold
•
ALTER – to change something that has been established, e.g. change the size of a disk
•
DROP – to delete something, e.g. a dropping a disk
•
DESCRIBE – to display the various attributes of an object
There are more verbs but these five are the most common ones among the CellCLI commands. Let’s see how they are used in common operations. In the following sections you will learn how to perform the management operations – View, Creation, Deletion and Modification – of various components of the storage, e.g. Physical Disks, Grid Disks, LUN, etc. Physical Disk Operations Storage cell is all about disks. As you learned in first two installments, each storage cell has 12 physical disks. To display the physical disks in this particular cell, you execute the following command: CellCLI> list physicaldisk 34:0 E1K5JW normal 34:1 E1L9NC normal … output truncted … [4:0:2:0] 5080020000f3e16FMOD2 normal [4:0:3:0] 5080020000f3e16FMOD3 normal You can notice that there is no heading above the output, making it difficult to understand what these values mean. Fortunately we can fix that as we will see later. For now let’s focus on something else: To know more detail about each disk, you can use the detailmodifier. It will show details on each disk. Here is a partial output: CellCLI> list physicaldisk detail name: 34:0 deviceId: 33 diskType: HardDisk enclosureDeviceId: 34 errMediaCount: 0 errOtherCount: 0 foreignState: false luns: 0_0 makeModel: "SEAGATE ST360057SSUN600G" physicalFirmware: 0805 physicalInsertTime: 2011-01-21T14:32:35-05:00 physicalInterface: sas physicalSerial: XXXXXX physicalSize: 558.9109999993816G slotNumber: 0 status: normal name: 34:1 deviceId: 32 diskType: HardDisk enclosureDeviceId: 34 errMediaCount: 0 errOtherCount: 0 foreignState: false luns: 0_1 makeModel: "SEAGATE ST360057SSUN600G" physicalFirmware: 0805 physicalInsertTime: 2011-01-21T14:32:40-05:00 physicalInterface: sas physicalSerial: XXXXXX physicalSize: 558.9109999993816G slotNumber: 1 status: normal … output truncated … The output shows the details of every disk, making it somewhat unreadable. Many times when you encounter issues with specific disks you may want to find the details of a particular disk. For that, use the name of the disk as another modifier. The name is shown in both types of commands, normal and detail.
CellCLI> list physicaldisk 34:0 CellCLI> list physicaldisk 34:0 detail
Attributes While the above command is useful for reading, it lacks a few things.
•
You still don’t get a lot of other details. For instance the RPM of the disk is not shown.
•
The results are not in a tabular format, if you want to see more than one disk.
To get these details you can specify named “attributes” in the listing. You can specify these attributes after the modifier attribute. In this example, we have type of the disk (hard disk, or flash disk), model, RPM, Port, and status: CellCLI> list physicaldisk attributes name, disktype, makemodel, physicalrpm, physicalport, status 34:0 HardDisk "SEAGATE ST360057SSUN600G" normal 34:1 HardDisk "SEAGATE ST360057SSUN600G" normal … output truncated … [4:0:2:0] FlashDisk "MARVELL SD88SA02" normal [4:0:3:0] FlashDisk "MARVELL SD88SA02" normal This is a much better output that shows the details against each disk. This type of output is quite useful in scripts where you may want to pull the details and format them in certain pre-specified manner or parse them for further processing.
Describe While you may appreciate the above output where using attributes specifically increased the readability of the output, you may also wonder what the valid names of these attributes are. The attribute names vary with the object as well. (For example, diskType is relevant in case of disks only, not in cells.) Do you need to remember all of them and the context in which they are relevant? Not at all. That’s where a different verb DESCRIBE comes handy; it shows the attributes of an object, similar to what the describe command in SQL*Plus command does for a table to display the columns. Here is how you display the attributes of the physicaldisk object. Remember, unlike SQL*Plus, the command isdescribe; it cannot be shortened to desc. CellCLI> describe physicaldisk name ctrlFirmware ctrlHwVersion deviceId diskType enclosureDeviceId errCmdTimeoutCount errHardReadCount errHardWriteCount errMediaCount errOtherCount errSeekCount errorCount foreignState hotPlugCount lastFailureReason luns makeModel notPresentSince physicalFirmware physicalInsertTime physicalInterface physicalPort
physicalRPM physicalSerial physicalSize physicalUseType sectorRemapCount slotNumber status What if you want to display all the attributes of the physical disks; not just a few? You can list all the attribute names explicitly; or – as an easier way – you can just use the option all, as shown below. CellCLI> list physicaldisk attributes all 34:0
33
0 0805 0
34
0_0
2011-01-21T14:32:35-05:00
0 "SEAGATE ST360057SSUN600G"
sas
E1K5JW
558.9109999993816G
normal 34:1
32
0
HardDisk false
0805 1
HardDisk false
34
0_1
2011-01-21T14:32:40-05:00
0 "SEAGATE ST360057SSUN600G"
sas
E1L9NC
558.9109999993816G
normal
… output truncated … [1:0:0:0] 21T14:33:32-05:00 4; FDOM: 0"
FlashDisk sas
4_0
5080020000f21a2FMOD0
"MARVELL SD88SA02"
D20Y
22.8880615234375G
2011-01"PCI Slot:
normal
[1:0:1:0] 21T14:33:32-05:00
FlashDisk sas
4_1
5080020000f21a2FMOD1
"MARVELL SD88SA02"
D20Y
2011-01-
22.8880615234375G
… output truncated …
This output may not be very useful for reading but if you want to write a script to parse these details and take corrective action, it becomes extremely useful. However, in many cases you may want to see only a certain attributes; not all. In the previous subsection you saw how to select only a few of these attributes.
Checking for Errors Let’s see a practical use of the named attributes clause. From time to time you will see errors popping up on disk drives, which may have to be replaced. To show the error related attributes, you may choose a script to select only a few attributes related to errors, as shown below: CellCLI> list physicaldisk attributes name,disktype,errCmdTimeoutCount,errHardReadCount,errHardWriteCount 34:0 HardDisk … output truncated … 34:11 HardDisk [1:0:0:0] FlashDisk … output truncated … [4:0:3:0] FlashDisk There is no error on any of these disks; so you see those fields remaining unpopulated.
Filtering What if you are interested in only a certain type of disk, or filter on some attribute? You can use the SQL-esque predicate WHERE clause. Here you want to see some attributes for all hard disks. CellCLI> list physicaldisk attributes name, physicalInterface, physicalInsertTime > where disktype = 'HardDisk' 34:0 sas 2011-01-21T14:32:35-05:00 34:1 sas 2011-01-21T14:32:40-05:00 34:2 sas 2011-01-21T14:32:45-05:00 34:3 sas 2011-01-21T14:32:50-05:00 34:4 sas 2011-01-21T14:32:55-05:00 34:5 sas 2011-01-21T14:33:01-05:00
34:6 34:7 34:8 34:9 34:10 34:11
sas sas sas sas sas sas
2011-01-21T14:33:06-05:00 2011-01-21T14:33:11-05:00 2011-01-21T14:33:16-05:00 2011-01-21T14:33:21-05:00 2011-01-21T14:33:26-05:00 2011-01-21T14:33:32-05:00
If you want to change the way the date and time are displayed, you can set the dateformat environmental variable. CellCLI> set dateformat local Date format was set: Apr 1, 2011 4:05:54 PM. CellCLI> list physicaldisk attributes name, physicalInterface, physicalInsertTime > where disktype = 'HardDisk' 34:0 sas Jan 21, 2011 2:32:35 PM 34:1 sas Jan 21, 2011 2:32:40 PM … output truncated … Filtering can also be specified with negation, i.e. !=. CellCLI> list physicaldisk where diskType='Flashdisk' [1:0:0:0] 5080020000f21a2FMOD0 normal [1:0:1:0] 5080020000f21a2FMOD1 normal … output truncated … CellCLI> list physicaldisk where diskType!='Flashdisk' 34:0 E1K5JW normal 34:1 E1L9NC normal … output truncated …
Modifications Now that you know how to display the objects, let’s see how you can modify the properties. The properties of the physical disks are not modifiable, except one: the display of service LED. You can turn on or off the service LED of disks 34:0 and 34:1 by issuing the following commands. CellCLI> alter physicaldisk 34:0,34:1 serviceled on CellCLI> alter physicaldisk 34:0,34:1 serviceled off To turn service LED on all the hard disks of that cell, use the following command: CellCLI> alter physicaldisk harddisk serviceled on On all disks (hard disks and flash disks): CellCLI> alter physicaldisk all serviceled on
Creation There is no creation operation of physical disks because they come with the Exadata machine.
Deletion There is no deletion operation of physical disks either because they have to be removed by an engineer. Managing LUN From the earlier installments you learned that the physical disks are carved up into LUNs. Let’s see the common LUN management commands. To show the LUNs in this cell, you use the following command: CellCLI> list lun 0_0 0_0 normal 0_1 0_1 normal 0_2 0_2 normal … output truncated … As in the case of physical disks, you can also display the details of these LUNs by the following command:
CellCLI> list lun detail name: 0_0 cellDisk: CD_00_cell01 deviceName: /dev/sda diskType: HardDisk id: 0_0 isSystemLun: TRUE lunAutoCreate: FALSE lunSize: 557.861328125G lunUID: 0_0 physicalDrives: 34:0 raidLevel: 0 lunWriteCacheMode: "WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU" status: normal name: 0_1 cellDisk: CD_01_cell01 … output truncated … If you want the details for one specific LUN, use its name as the modifier. CellCLI> list lun 0_0 detail Like the previous cases you can show the LUNs in a tabular format by selecting all the attributes as well: CellCLI> list lun attributes all 0_0
CD_00_cell01
557.861328125G
0_0
Cache if Bad BBU"
/dev/sda 34:0
HardDisk 0
0_0
TRUE
FALSE
"WriteBack, ReadAheadNone, Direct, No Write
normal
… output truncated … 0_11
CD_11_cell01
557.861328125G
0_11
Cache if Bad BBU"
/dev/sdl 34:11
HardDisk 0
0_11
FALSE
FALSE
"WriteBack, ReadAheadNone, Direct, No Write
normal
1_0
FD_00_cell01
22.8880615234375G
100.0
/dev/sdq [2:0:0:0]
FlashDisk
1_0
FALSE
FALSE
5_3
FALSE
FALSE
normal
… output truncated … 5_3
FD_15_cell01
22.8880615234375G
100.0
/dev/sdx [3:0:3:0]
FlashDisk normal
If you want to see the available attributes of a LUN, use the describe command. CellCLI> describe LUN name cellDisk deviceName diskType errorCount id isSystemLun lunAutoCreate lunSize lunUID overProvisioning physicalDrives raidLevel lunWriteCacheMode status You can use any of these attributes instead of “all”. CellCLI> list lun attributes name, cellDisk, raidLevel, status 0_0 CD_00_prolcel14 0 normal
0_1 CD_01_prolcel14 0_2 CD_02_prolcel14 … output truncated …
0 0
normal normal
Modification The properties of a LUN are not modifiable, except one. The LUNs are re-enabled after a failure. If one is not automatically re-enabled after the failure is corrected, you can manually re-enable it by the following command: CEllCLI> alter lun 0_0 reenable Sometimes the LUN may be already enabled but may not be shown as such. To resync this reality with the system, you may need to enable it forceably. The force modifier allows that. CEllCLI> alter lun 0_0 reenable force
Deletion There is no delete operation for LUNs in the CellCLI.
Creation Similarly you don’t create LUNs in CellCLI so there is no create lun command. Managing Cells From the previous installments you learned that storage cells, also called simply cells, are where the disks are located and they are presented to the database nodes. A full rack of Exadata contains fourteen such cells. To display the information on cells, you give the list cell command. CellCLI> list cell Cell01 online The output does not say much except the name of the cell and if it is online. To display more information, use the detail modifier. CellCLI> list cell detail name: cell01 bmcType: IPMI cellVersion: OSS_11.2.0.3.0_LINUX.X64_101206.2 cpuCount: 24 fanCount: 12/12 fanStatus: normal id: XXXXXXXXXX interconnectCount: 3 interconnect1: bondib0 iormBoost: 0.0 ipaddress1: 172.32.128.9/24 kernelVersion: 2.6.18-194.3.1.0.3.el5 locatorLEDStatus: off makeModel: SUN MICROSYSTEMS SUN FIRE X4270 M2 SERVER SAS metricHistoryDays: 7 notificationMethod: mail notificationPolicy: critical,warning,clear offloadEfficiency: 372.1M powerCount: 2/2 powerStatus: normal smtpFrom: "Proligence Test Database Machine" smtpFromAddr:
[email protected] smtpPort: 25 smtpPwd: ****** smtpServer: standardrelay.proligence.com smtpToAddr:
[email protected],
[email protected],
[email protected] smtpUser: smtpUseSSL: FALSE
status: online temperatureReading: 24.0 temperatureStatus: normal upTime: 32 days, 4:44 cellsrvStatus: running msStatus: running rsStatus: running You will understand the meaning of all these attributes as you explore the cell modifications later in this section.To display the output in a tabular format in one line, as you saw in the case of the physical disks, use the attribute modifier: CellCLI> list cell attributes all cell01 XXXXXXXX
IPMI
OSS_11.2.0.3.0_LINUX.X64_101206.2
3
bondib0
0.0
off
SUN MICROSYSTEMS SUN FIRE X4270 M2 SERVER SAS
372.1M
2/2
******
standardrelay.proligence.com
normal
24
172.32.128.9/24 7
"Proligence Test Database Machine"
12/12
normal
2.6.18-194.3.1.0.3.el5 mail
critical,warning,clear
[email protected]
25
[email protected],
[email protected],
[email protected] FALSE
online
25.0
normal
32 days, 21:52
running
running
running
The output comes as one line containing all the attributes. Of course, you can use specific attributes as you did in other cases. To see all the available attributes, use the previously explained describe command. CellCLI> describe cell name modifiable bmcType cellNumber modifiable cellVersion comment modifiable cpuCount emailFormat modifiable events modifiable fanCount fanStatus id interconnectCount interconnect1 modifiable interconnect2 modifiable interconnect3 modifiable interconnect4 modifiable iormBoost ipBlock modifiable ipaddress1 modifiable ipaddress2 modifiable ipaddress3 modifiable ipaddress4 modifiable kernelVersion locatorLEDStatus location modifiable makeModel metricCollection modifiable metricHistoryDays modifiable notificationMethod modifiable notificationPolicy modifiable offloadEfficiency powerCount powerStatus realmName modifiable smtpFrom modifiable smtpFromAddr modifiable
smtpPort smtpPwd smtpServer smtpToAddr smtpUser smtpUseSSL snmpSubscriber status temperatureReading temperatureStatus traceLevel upTime cellsrvStatus msStatus rsStatus
modifiable modifiable modifiable modifiable modifiable modifiable modifiable
modifiable
Modification The word modifiable above means that specific attribute can be modified by an ALTER verb. It’s not possible to give all the possible combinations in this short article and not all are used often anyway; so, let’s see the most common ones. A cell runs muliple services, e.g. the Restart Server, the Management Server and Cell Services. To shut down a cell, you can shut down specific services by name or the entire service. To shutdown only one service, e.g. the Restart Server service, execute: CellCLI> alter cell shutdown services rs Stopping RS services... The SHUTDOWN of RS services was successful. To restart that particular service, use the restart modifier, shown below: CellCLI> alter cell restart services rs Stopping RS services... CELL-01509: Restart Server (RS) not responding. Starting the RS services... Getting the state of RS services... Running At any point you can confirm it by checking the status: CellCLI> list cell attributes rsStatus running To shutdown the Management Server, execute: CellCLI> alter cell shutdown services MS To shutdown the Cell Services, execute: CellCLI> alter cell shutdown services CELLSRV What if you want to shutdown the entire cell? The “all” modifier is a shotcut to shutdown all the services: CellCLI> alter cell shutdown services all Stopping the RS, CELLSRV, and MS services... The SHUTDOWN of services was successful. To restart all the services, execute the following command: CellCLI> alter cell restart services all Starting the RS, CELLSRV, and MS services... Getting the state of RS services... running Starting CELLSRV services... The STARTUP of CELLSRV services was successful.
Starting MS services... The STARTUP of MS services was successful. To turn on or off the LED on the chassis of the cell, execute: CellCLI> alter cell led on CellCLI> alter cell led off
Mail Setup The cell can communicate its status by sending emails. So configuration of email is vital for the proper monitoring of cells. In this section you will learn how to do that. First, verify the status of the email configuration in the cell. CellCLI> alter cell validate mail CELL-02578: An error was detected in the SMTP configuration: CELL-05503: An error was detected during notification. The text of the associated internal error is: Could not connect to SMTP host: standardrelay.proligence.com, port: 25, response: 421. The notification recipient is
[email protected]. CELL-05503: An error was detected during notification. The text of the associated internal error is: Could not connect to SMTP host: standardrelay.proligence.com, port: 25, response: 421. The notification recipient is
[email protected]. CELL-05503: An error was detected during notification. The text of the associated internal error is: Could not connect to SMTP host: standardrelay.proligence.com, port: 25, response: 421. The notification recipient is
[email protected].
Please verify your SMTP configuration. The above output shows that the mail setup has not been done properly, meaning the cell will not be able to send accurate mails required for monitoring. Let’s configure the mail correctly. First, let’s configue the address and name of the sender, i.e. the Cell 07 (this cell). We will give it an address of
[email protected]. That address may or may not actually exist in the mail server; it’s not important. When the emails come, this address will be shown as the sender. We will also give a name to the sender, i.e. “Exadata Cell 07”, which helps us indetify the sender in the email. CellCLI> alter cell smtpfromaddr='
[email protected]' Cell cell07 successfully altered CellCLI> alter cell smtpfrom='Exadata Cell 07' Cell cell07 successfully altered Then, we configure the address the cell should the emails to. This is typically the on-call DBA or DMA. You can configure more than one address as well. CellCLI> alter cell smtptoaddr='
[email protected]' Cell cell07 successfully altered The cell can send he mails as text or html, which can be configured as shown below. CellCLI> alter cell emailFormat='text' Cell cell07 successfully altered CellCLI> alter cell emailFormat='html' Cell cell07 successfully altered With all these in place, let’s make sure the email works. You can validate the email setup by executing the following: CellCLI> alter cell validate mail Cell cell07 successfully altered If the setup is correct, you will receive a mail from
[email protected] (The email you configured as the sender). Here is the body of that email. This test e-mail message from Oracle Cell cell07 indicates successful configuration of your e-mail address and mail server. You may wonder what type of emails the cell sends out. Here is an email sent by the cell when there is a hardware failure:
And here is the email on another failure of the cell disk as a result of flashdisk failure.
BMC Management BMC, or Baseboard Management Controller, controls the compoments of the cell. The BMC should be running all the time. You can restart it, if needed by executing the command below. The comamnd also reboots the BMC if it is already running. CellCLI> alter cell restart bmc To make sure the BMC sends the alerts to the cell so that they show up as alerts, execute CellCLI> alter cell configurebmc Cell Cell07 BMC configured successfully The cells can also send SNMP traps. Any monitoring system based on SNMP traps can receive and process these SNMP traps to show the statistics on cells. To validate the SNMP configuration to be use dfor Automatic Service Requests (ASRs), use the following command: CellCLI> alter cell validate snmp type=ASR Cell cell01 successfully altered To enable automatic service request generation by the SNMP, youneed to define a subscriber. Here is an example: CellCLI> alter cell snmpsubscriber=((host='snmp01.proligence.com,type=ASR')) Cell cell01 successfully altered You may want to validate the firmware of the cell at any time by executing CellCLI> alter cell validate configuration Cell cell07 successfully altered Finally, if you want to reset the cell to its factory settings, use: CellCLI> drop cell If you have defined griddisks in this cell, you have to drop them first. Otherwise the following forces them to be dropped.
CellCLI> drop cell force Remember, the drop cell command removes the sell related properties of the server; it does not actually remove the physical server. Creation The cells are created in the beginning of the project, and is usually done via the automatic installation script. Later, you will not likely use this command but it’s shown here briefly for the sake of completeness. The command is create cell. Here is the help on the command: CellCLI> help create cell Usage: CREATE CELL [] [realmname=,] [interconnect1=,] [interconnect2=,] [interconnect3=,] [interconnect4=,] ( ( [ipaddress1=,] [ipaddress2=,] [ipaddress3=,] [ipaddress4=,] ) | ( [ipblock=, cellnumber=] ) ) Purpose: Configures the cell network and starts services. Arguments: : Name to be assigned to the cell. Uses hostname if nothing is specified : Name of the realm this cell belongs to. : Value of the eth interconnect assigned to this network interconnect. : Value of the IP address to be assigned to this network interconnect. : Value of the IP block to determine IP address for the network. : Number of the cell in this ip block. Managing Cell Disks Each physical disk in the cell is further exposed as cell disks. To show all the cell disks in this cell, use the list celldisk command as shown below. CellCLI> list celldisk CD_00_prolcel14 normal CD_01_prolcel14 normal CD_02_prolcel14 normal … output truncated … This is a rather succinct output without much useful detail. The detail modifier allows display of more detailed information on the cell disks. CellCLI> list celldisk detail name: CD_00_prolcel14 comment: creationTime: 2011-04-27T15:11:27-04:00 deviceName: /dev/sda devicePartition: /dev/sda3 diskType: HardDisk errorCount: 0 freeSpace: 0 id: xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx interleaving: none lun: 0_0 raidLevel: 0 size: 1832.59375G status: normal name: CD_01_prolcel14 … output truncated … This output shows all the cell disks one after the other, which makes up a rather long and unreadable list. If you would rather want to show the details in a tabular format with one line per cell disk, use the attribute all modifier shown below:
CellCLI> list celldisk attributes all CD_00_cell01
Mar 1, 2011 6:20:45 PM
HardDisk
0
0
0
528.734375G
/dev/sda
xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx
none
/dev/sda3 0_0
normal
… output truncated … FD_00_cell01 FlashDisk
0
22.875G
normal
Jan 21, 2011 5:07:32 PM 0
/dev/sdq
xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx
none
/dev/sdq 1_0
To know the columns, or rather the attributes shown here, use the describe command to display the attributes of the cell disk. CellCLI> describe celldisk name modifiable comment modifiable creationTime deviceName devicePartition diskType errorCount freeSpace freeSpaceMap id interleaving lun physicalDisk raidLevel size status The output columns are displayed in the same order. You can select only a few attributes from this list instead of all. For instance, let’s see only name of the cell disk and the corresponding Linux partition name. CellCLI> list celldisk attributes name, devicePartition CD_00_prolcel14 /dev/sda3 CD_01_prolcel14 /dev/sdb3 … output truncated … Similarly you can use the attributes for filtering the output as well. The following shows an example where you wanted to see all cell disks larger than 23GB. CellCLI> list celldisk attributes name, devicePartition where size>23G CD_00_prolcel14 /dev/sda3 CD_01_prolcel14 /dev/sdb3 CD_02_prolcel14 /dev/sdc CD_03_prolcel14 /dev/sdd CD_04_prolcel14 /dev/sde CD_05_prolcel14 /dev/sdf CD_06_prolcel14 /dev/sdg CD_07_prolcel14 /dev/sdh CD_08_prolcel14 /dev/sdi CD_09_prolcel14 /dev/sdj CD_10_prolcel14 /dev/sdk CD_11_prolcel14 /dev/sdl
Modification Only two attributes of the cell disks are changeable: the comment and the name. Suppose you want to add a comment “Flash Disk” to the cell disk FD_00_cell01. You need to execute: CellCLI> alter celldisk FD_00_cell01 comment='Flash Disk'
If you want to make the change to comments on all the hard disks, you would issue: CellCLI> alter celldisk all harddisk comment=’Hard Disk’ CellDisk CD_00_cell01 successfully altered CellDisk CD_01_cell01 successfully altered … output truncated … Similarly if you want to change the comment on all the flash disks: CellCLI> alter celldisk all flashdisk comment='Flash Disk'
Deletion This command is rarely used but it may be needed when cell disks fail and you want to drop the cell disks and create them fresh. Here is how to drop the cell disk named CD_00_cell01: CellCLI> drop celldisk CD_00_cell01 If the cell disk contains grid disks, the drop command will fail. Either drop the grid disks (described in the next section) or use the force option. CellCLI> drop celldisk CD_00_cell01 force You can also drop all cell disks of certain types, e.g. hard disks or flash disks. CellCLI> drop celldisk harddisk CellCLI> drop celldisk flashdisk Or, drop them all: CellCLI> drop celldisk all Managing Grid Disks In the previous installments you learned that grid disks are carved out of the cell disks and the grid disks are presented to the ASM instance as disks, which are eventually used to build ASM diskgroups. CellCLI> list griddisk DBFS_DG_CD_02_prolcel14 DBFS_DG_CD_03_prolcel14 DBFS_DG_CD_04_prolcel14 … output truncated … Or you can get the details of a specific grid disk:
active active active
CellCLI> list griddisk DBFS_DG_CD_02_cell01 detail name: DBFS_DG_CD_02_cell01 availableTo: cellDisk: CD_02_cell01 comment: creationTime: 2011-03-01T18:21:41-05:00 diskType: HardDisk errorCount: 0 id: xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx offset: 528.734375G size: 29.125G status: active As with the previous cases, you can also see: CellCLI> describe griddisk name availableTo cellDisk comment creationTime diskType
modifiable modifiable modifiable
errorCount id offset size modifiable status You can use these keywords to display specific – not all – attributes of the grid disks. Here is a command to display the name, the cell disks, and the type of the disk: CellCLI> list griddisk attributes name,cellDisk,diskType DBFS_DG_CD_02_prolcel14 CD_02_prolcel14 DBFS_DG_CD_03_prolcel14 CD_03_prolcel14 DBFS_DG_CD_04_prolcel14 CD_04_prolcel14 … output truncated … You could have also used the following to show all the attributes:
HardDisk HardDisk HardDisk
CellCLI> list griddisk attributes all If you want to show details for a certain type of attribute only, you can use the filter before the attributes modifier. The following shows the command to show all the grid disks of size 476.546875GB: CellCLI> list griddisk attributes name,cellDisk,status where size=476.546875G PRORECO_CD_00_prolcel14 CD_00_prolcel14 active PRORECO_CD_01_prolcel14 CD_01_prolcel14 active PRORECO_CD_02_prolcel14 CD_02_prolcel14 active PRORECO_CD_03_prolcel14 CD_03_prolcel14 active … output truncated …
ASM Status The describe command does not show two important attributes:
•
ASMModeStatus – whether a current ASM diskgroup is using this griddisk. A value of ONLINE indicates this grid disk is being used.
•
ASMDeactivationOutcome – recall that grid disks can be deactivated, which is effectively taking them offline. Since ASM mirroring ensures that the data is located on another disk, making this disk offline does not lose data. However, if the mirror is offline, or is not present, then making this grid disk offline will result in loss of data. This attribute shows whether the grid disk can be deactivated without loss of data. A value of “Yes” indicates you can deactivate this grid disk without data loss. CellCLI> list griddisk attributes name, ASMDeactivationOutcome, ASMModeStatus DBFS_DG_CD_02_cell01 Yes ONLINE DBFS_DG_CD_03_cell01 Yes ONLINE DBFS_DG_CD_04_cell01 Yes ONLINE … output truncated …
Modification Only name, comment, Available To, status and size are modifiable. Let’s see how to change the comment for a specific grid disk: CellCLI> alter griddisk PRORECO_CD_11_cell01 comment='Used for Reco'; GridDisk PRORECO_CD_11_cell01 successfully altered You can change the comment for all the grid disks of a cetain time, e.g. all hard disks: CellCLI> alter griddisk all harddisk comment='Hard Disk'; GridDisk DBFS_DG_CD_02_cell01 successfully altered GridDisk DBFS_DG_CD_03_cell01 successfully altered … output truncated … Making a grid disk inactive effectively offlines its associated ASM disk.
CellCLI> alter griddisk PRORECO_CD_11_cell01 inactive GridDisk PRORECO_CD_11_cell01 successfully altered In the process of doing so, you can use force, which forces the ASM disk to become offline even there is data on that disk. CellCLI> alter griddisk PRORECO_CD_11_cell01 inactive force The command will wait until the ASM disk becomes offline. If you want the prompt to come back immediately without waiting, you can use nowait clause. CellCLI> alter griddisk PRORECO_CD_11_cell01 inactive nowait You can make it active again: CellCLI> alter griddisk PRORECO_CD_11_cell01 active GridDisk PRORECO_CD_11_cell01 successfully altered
Deletion You rarely have to drop grid disks but some situations may warrant it (if you want to swap disks, for example.) You can do that by dropping the old one and creating a new one. Here is how you drop a specific named grid disk. CellCLI> drop griddisk DBFS_DG_CD_02_prolcel14 Sometimes you may want to drop a number of grid disks. You can drop all grid disks with a specific prefix in their name, e.g. DBFS. CellCLI> drop griddisk prefix=DBFS Or, you can drop all the grid disks from this cell: CellCLI> drop griddisk all Sometimes you may want to drop all the grid disks of only a specific type – hard disks or flash disks. You will then execute one of the following: CellCLI> drop griddisk flashdisk CellCLI> drop griddisk harddisk If the disk is active, it won’t be dropped. Here is an example: CellCLI> drop griddisk PRORECO_CD_11_cell01; CELL-02549: Grid disk is in use and FORCE is not specified for the operation. In that case, you can force drop the disk using the force modifier. CellCLI> drop griddisk PRORECO_CD_11_cell01 force GridDisk PRORECO_CD_11_cell01 successfully dropped
Creation Rarely will you need to create grid disks but you may need to for the same reason you drop them. The create griddisk command does it. Here is an example showing how to create a grid disk from a specific cell disk. CellCLI> create griddisk PRORECO_CD_11_cell01 celldisk=CD_11_cell01 GridDisk PRORECO_CD_11_cell01 successfully created If you want to create a grid disk in each cell disk, you can create them individually, or you can use a shortcut: CellCLI> create griddisk all prefix PRORECO This will create a grid disk in the naming convention _, which is usually the name of the database. But you can also use the type of the disk – hard or flash as a prefix instead of the database name. CellCLI> create griddisk all flashdisk prefix FLASH You can optionally specify a size, which can be less than or equal to that of the celldisk. CellCLI> create griddisk PRORECO_CD_11_cell01 celldisk=CD_11_cell01 size=100M You may want to specify a smaller size to keep less data on the disks.
Managing Flash Disks As you recall, each storage cell comes with several flash disk cards and they are presented to the cells as cell disks. Each cell has only one flash cache, which is made up of the various flash disks as the cell disks. To see the flash cache, use: CellCLI> list flashcache cell01_FLASHCACHE normal Of course the pithy output does not tell us much. The detail modifier takes care of that by displaying a lot more: CellCLI> list flashcache detail name:
cell01_FLASHCACHE
cellDisk: FD_13_cell01,FD_00_cell01,FD_10_cell01,FD_02_cell01,FD_06_cell01,FD_12_cell01,FD_05_cell01,FD_08_cel l01,FD_15_cell01,FD_14_cell01,FD_07_cell01,FD_04_cell01, FD_03_cell01,FD_11_cell01,FD_09_cell01,FD_01_cell01 creationTime:
2011-01-21T17:07:43-05:00
degradedCelldisks: effectiveCacheSize:
365.25G
id:
xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx
size:
365.25G
status:
normal
The output shows various important data on the flash cache configured for the cell:
1. The flash disks configured as cell disks, e.g. FD_00_cell01, FD_01_cell01, etc. You can get information on these cell disks by list celldisk command, as shown previously. Here is another example: CellCLI> list celldisk FD_00_cell01 detail name: FD_00_cell01 comment: "Flash Disk" creationTime: 2011-01-21T17:07:32-05:00 deviceName: /dev/sdq devicePartition: /dev/sdq diskType: FlashDisk errorCount: 0 freeSpace: 0 id: xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx interleaving: none lun: 1_0 size: 22.875G status: normal 2. The total size is 365.25GB. 3. It’s available. You can also get the output in a single line: CellCLI> list flashcache attributes all cell01_FLASHCACHE FD_13_cell01,FD_00_cell01,FD_10_cell01,FD_02_cell01,FD_06_cell01,FD_12_cell01,FD_05_cell01,FD_08_cel l01,FD_15_cell01,FD_14_cell01,FD_07_cell01, FD_04_cell01,FD_03_cell01,FD_11_cell01,FD_09_cell01,FD_01_cell01 05:00
365.25G
2011-01-21T17:07:43-
686510aa-1f06-4ee7-ab84-743db1ae01d8
Like the previous cases, you can see what attributes are available for the flashcache. CellCLI> describe flashcache name cellDisk creationTime degradedCelldisks effectiveCacheSize id
365.25G normal
size status From these you can list only a subset of the attributes: CellCLI> list flashcache attributes degradedCelldisks
Modification There is no modification operation for flash cache.
Creation You create the flash cache using the create flashcache command. You will at least need to specify the cell disks created on the flash disks. CellCLI> create flashcachecelldisk='FD_13_cell01,FD_00_cell01,FD_10_cell01,FD_02_cell01,FD_06_cell01,FD_12_cell01,FD _05_cell01,FD_08_cell01,FD_15_cell01,FD_14_cell01,FD_07_cell01, FD_04_cell01,FD_03_cell01,FD_11_cell01,FD_09_cell01,FD_01_cell01'
If you want to use all the flash-based cell disks, you can use: CellCLI> create flashcache all Flash cache cell01_FLASHCACHE successfully created To specify a certain size: CellCLI> create flashcache all size=365.25G If you want to use only a few cell disks as flash cache and the rest as a grid disks to be ultimately used by ASM diskgroups, you can use only a handful of the cell disks. CellCLI> create flashcache celldisk='FD_00_cell01' Flash cache cell01_FLASHCACHE successfully created The rest of the flash disks can be used as grid disks and then used for ASM disk groups. Note how the flash cache size is reduced now. CellCLI> list flashcache detail name: cellDisk: creationTime: degradedCelldisks: effectiveCacheSize: id: size: status:
cell01_FLASHCACHE FD_00_cell01 2011-05-15T15:03:44-04:00 22.828125G xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx 22.828125G normal
Deletion You generally don’t need to drop the flash cache, except under one circumstance: when you want to use part (or none) of the flash disks as storage and not as flash cache. To drop the flash cache from the cell, use the following command. CellCLI> drop flashcache Flash cache cell01_FLASHCACHE successfully dropped After that you can either create the flash cache with fewer cell disks or not create it at all. Flash Cache Content Remember the purpose of the flash disks? To recap, their purpose is to provide a secondary buffer, known as flash cache. You've already learned how to manage the flash cache, but that brings up a very important point: How do you know if the flash cache has been effective? A simple check is to look for the contents of the flash cache. To display the contents, use the following command. Beware, in a production system where a lot of data may be cached, this output may be very long. You can always press Control-C to break the output.
CellCLI> list flashcachecontent cachedKeepSize: 0 cachedSize: 81920 dbID: 374480170 dbUniqueName: PROPRD hitCount: 5 missCount: 0 objectNumber: 131483 tableSpaceNumber: 729 cachedKeepSize: 0 cachedSize: 65536 dbID: 374480170 dbUniqueName: PROPRD hitCount: 5 missCount: 0 objectNumber: 131484 tableSpaceNumber: 729 … output truncated … The output shows all the contents of the flash cache. In the previous example, it shows some important data:
• • •
dbID and dbUniqueName – DBID and name of the database of whose contents are in the flash cache. Remember, the DBM may contain more than one database so you should know how much is from which database. objectNumber – the DATA_OBJECT_ID (not OBJECT_ID) value from DBA_OBJECTS view for the database object which is in the cache. tableSpaceNumber – the tablespace where the object is stored in the database.
Other data points are self explanatory. If you want to see what all attributes of the flash cache contents are visible, you can use theattribute command shown below. CellCLI> describe flashcachecontent cachedKeepSize cachedSize dbID dbUniqueName hitCount hoursToExpiration missCount objectNumber tableSpaceNumber Let’s see with an example table called MONTEST1. First we need to know its data_object_id, which is the same as object_id in most cases, except where the segments may be different, e.g. in case of partitioned tables, materialized views and indexes. SQL> select object_id, data_object_id from user_objects 2 where object_name = 'MONTEST1'; OBJECT_ID DATA_OBJECT_ID ---------- -------------211409 211409 In this case the data_object_id and object_id are the same, because this is an non-partitioned table. Now, let’s see how many fragments of this table are in the flash cache: CellCLI> list flashcachecontent where objectnumber=211409 detail cachedKeepSize: 0 cachedSize: 1048576 dbID: 374480170 dbUniqueName: PROPRD
hitCount: 48 missCount: 2237 objectNumber: 211409 tableSpaceNumber: 846 … output truncated … The output shows the chunks of the data from this segment in the flash cache. You could also use the same technique to find the objects of a single tablespace in the cache. You need to know the tablespace number, which is something you can get from the table TS$ in the SYS schema. In the output above, we see that the cache chunk is from the tablespace 846. If you want to check the tablespace name, use the following query: SQL> select name 2 from ts$ 3 where ts# = 846; NAME -----------------------------USERS_DATA Conversely, you can get the tablespace number from the name and use it to check the cache entries from CellCLI.
Creation There is no creation operation for flash cache content. Data goes in there by the way of normal operations.
Modification There is no modification operation; the flash cache is managed by the Exadata Storage Server software.
Deletion There is no deletion operation since the entries are deleted from the cache by the Exadata Storage Server software. Group Commands – DCLI So far you have seen all the commands possible through CellCLI, which applies to the cell you are logged into at that time. What if you want to manage something on all the cells? For instance, suppose you want to list the status of all 14 cells in the Exadata full-rack database machine. CellCLI’s list cell command gives that information right away, but for that cell only. You can log on to all the other 13 cells and issue the command to get the status – a process that is not only time consuming but which also may not work very well for scripting purposes, at least not easily. To address that, a new interface is available, named DCLI, which allows you to run commands on all other cells while logged in to single cell. Let’s see the original problem – you are logged in to cell01 and you want to check the status of cells 1 through 14. You then execute the dcli operation as shown below: [celladmin@prolcel01 ~]# dcli -c prolcel01,prolcel02,prolcel03,prolcel04,prolcel05,prolcel06,prolcel07,prolcel08, prolcel09,prolcel10,prolcel11,prolcel12,prolcel13,prolcel14 -l root "cellcli -e list cell" prolcel01: cell01 online prolcel02: cell02 online prolcel03: cell03 online prolcel04: cell04 online … output truncated … Let’s dissect the command.
• •
The last part of the command cellcli –e list cell is what we want to run on all the other cells. The -c option specifies the cells where this command cellcli –e list cell should be run
•
The -l option specifies the user the command should be run as. In this case it’s root. The default is celadmin.
The DCLI interface is not a command but rather a Python script that executes the command on the other cells. This remote execution is done by ssh command, therefore the cells should already have ssh equivalency. If you don’t have it, you can use dcli -k to establish it. Note the use of all the cell names with the -c option. What is you always select the cell names? The need to provide the cell names every time may not be convenient and is prone to mistakes. Another parameter, g (group), allows definition of a group of cells that can be addressed as a whole. First create a file called all_cells with the hostnames of the cells as shown below: [celladmin@prolcel01 ~]# cat all_cells prolcel01 prolcel02 prolcel03 prolcel04 prolcel05 prolcel06 prolcel07 prolcel08 prolcel09 prolcel10 prolcel11 prolcel12 prolcel13 prolcel14 With this file in place, you can pass this file to the group (-g) parameter of DCLI instead of the cell names: [celladmin@prolcel01 ~]# dcli -g all_cells -l root "cellcli -e list cell" If you want to see which cells are used as targets of the execution, you can use the -t option, for “target”. The hostnames of the cells where the commands from DCLI will be executed will be displayed. Suppose you made a mistake by not placing all the cells in that all_cells file but rather only 8, this command will show it clearly. [celladmin@prolcel01 ~]# dcli -g all_cells -t Target cells: ['prolcel01', 'prolcel02', 'prolcel03', 'prolcel04', 'prolcel05', 'prolcel06', 'prolcel07', 'prolcel08'] Only cells up to #8 were displayed. But DCLI is not just to execute CellCLI commands. It’s a remote execution tool. Any command that can be executed from the command line can be given to the DCLI interface to be executed remotely. One such command is vmstat. Suppose you want to get a quick pulse on all the cells by executing vmstat 2 2, you can pass it to the DCLI interface, as shown below: [celladmin@prolcel01 ~]# dcli -l root -g all_cells vmstat 2 2 prolcel01: procs -----------memory---------- ---swap-- -----io---- --system------cpu-----prolcel01: r b swpd free buff cache si so bi bo in cs us sy id wa st prolcel01: 1 0 0 9077396 381232 1189992 0 0 13 12 0 0 1 0 99 0 0 prolcel01: 0 0 0 9121764 381232 1190032 0 0 260 564 1143 25691 3 1 96 0 0 prolcel02: procs -----------memory---------- ---swap-- -----io---- --system------cpu-----prolcel02: r b swpd free buff cache si so bi bo in cs us sy id wa st
prolcel02: 1 0 0 9418412 350612 970424 0 0 7 10 0 0 0 0 99 0 0 prolcel02: 1 0 0 9417852 350612 970424 0 0 0 28 1047 23568 3 1 96 0 0 prolcel03: procs -----------memory---------- ---swap-- -----io---- --system------cpu-----prolcel03: r b swpd free buff cache si so bi bo in cs us sy id wa st prolcel03: 1 0 0 9312432 354948 1049780 0 0 7 12 0 0 0 0 99 0 0 prolcel03: 0 0 0 9313108 354948 1049892 0 0 0 60 1040 19046 0 0 100 0 0 prolcel04: procs -----------memory---------- ---swap-- -----io---- --system------cpu-----prolcel04: r b swpd free buff cache si so bi bo in cs us sy id wa st prolcel04: 0 0 0 9275392 360644 1080236 0 0 21 13 0 0 0 0 99 0 0 prolcel04: 0 0 0 9275788 360644 1080240 0 0 280 68 1093 17136 0 0 100 0 0 prolcel05: procs -----------memory---------- ---swap-- -----io---- --system------cpu-----prolcel05: r b swpd free buff cache si so bi bo in cs us sy id wa st prolcel05: 1 0 0 9200652 361064 1058544 0 0 6 12 0 0 0 0 99 0 0 prolcel05: 1 0 0 9200840 361064 1058544 0 0 0 52 1036 18000 0 4 96 0 0 prolcel06: procs -----------memory---------- ---swap-- -----io---- --system------cpu-----prolcel06: r b swpd free buff cache si so bi bo in cs us sy id wa st prolcel06: 0 0 0 9280912 354832 1057432 0 0 8 11 0 0 0 0 99 0 0 prolcel06: 0 0 0 9281388 354832 1057440 0 0 32 24 1040 18619 0 0 100 0 0 prolcel07: procs -----------memory---------- ---swap-- -----io---- --system------cpu-----prolcel07: r b swpd free buff cache si so bi bo in cs us sy id wa st prolcel07: 0 0 0 9795664 287140 877948 0 0 1 8 0 0 0 0 99 0 0 prolcel07: 0 0 0 9795136 287140 878004 0 0 0 36 1032 21026 0 1 99 0 0 prolcel08: procs -----------memory---------- ---swap-- -----io---- --system------cpu-----prolcel08: r b swpd free buff cache si so bi bo in cs us sy id wa st prolcel08: 0 0 0 9295716 320564 1043408 0 0 6 10 0 0 0 0 99 0 0 prolcel08: 0 0 0 9295740 320564 1043412 0 0 0 4 1014 21830 0 0 100 0 0 The output is useful in many ways. Not only it saved you the need of typing the command on all the cells, it displayed the output on the same page allowing you to compare the results across the cells. For instance, you may notice that the values for blocks out (bo) and blocks in (bi) in the output are not similar across all the cells. They are more in case cell01 and cell04, indicating higher IO activity in those cells.
Here is another example. Suppose you want to make sure that OSWatcher is running on all the cells. You can use the following command to check that. [celladmin@prolcel01 ~]# dcli -l root -g all_cells ps -aef|grep OSWatcher prolcel01: root 557 19331 0 Feb28 ? 00:15:08 /bin/ksh ./OSWatcherFM.sh 168 prolcel01: root 5886 24280 0 21:14 pts/0 00:00:00 grep OSWatcher prolcel01: root 19331 1 0 Feb28 ? 01:08:33 /bin/ksh ./OSWatcher.sh 15 168 bzip2 prolcel02: root 554 17501 0 Feb28 ? 00:14:47 /bin/ksh ./OSWatcherFM.sh 168 To complete the discussion on remote execution, please note that it can be executed on any of cells, where the current cell may be excluded. For instance, you are on cell01 and you want to check the status of a specific physical disk on cell08, you don’t need to logon to that cell to use the command. Right from cell0, you can use the dcli command with the -c option to execute on cell08, as shown below: [celladmin@prolcel01 ~]# dcli -l 20:8 detail" prolcel08: name: prolcel08: deviceId: prolcel08: diskType: prolcel08: enclosureDeviceId: prolcel08: errMediaCount: prolcel08: errOtherCount: prolcel08: foreignState: prolcel08: luns: prolcel08: makeModel: prolcel08: physicalFirmware: prolcel08: physicalInsertTime: prolcel08: physicalInterface: prolcel08: physicalSerial: prolcel08: physicalSize: prolcel08: slotNumber: prolcel08: status:
root -c prolcel08 cellcli -e "list physicaldisk 20:8 11 HardDisk 20 0 1 false 0_8 "SEAGATE ST360057SSUN600G" 0805 2011-01-21T14:23:57-05:00 sas XXXXXX 558.9109999993816G 8 normal
Modification Apart from checking values, DCLI is also useful to set values across a lot of cells at a time. For instance, suppose your mail SMTP server is changed and you need to set up a different value of smtServer for the cells. The alter cell smtpServer=’…’ command in CellCLI does that; but it needs to be executed on all the cells. Instead, we can use DCLI to execute them across all the cells specified as a group in the file all_cells, as shown below. [celladmin@prolcel01 ~]# dcli -l celladmin -g all_cells cellcli -e "alter cell smtpServer=\'smtp.proligence.com\'" prolcel01: Cell cell01 successfully altered prolcel02: Cell cell02 successfully altered prolcel03: Cell cell03 successfully altered prolcel04: Cell cell04 successfully altered prolcel05: Cell cell05 successfully altered prolcel06: Cell cell06 successfully altered prolcel07: Cell cell07 successfully altered prolcel08: Cell cell08 successfully altered Use the same technique to update the other SMTP parameters of the cell as well: [celladmin@prolcel01 ~]# dcli -l root -g all_cells cellcli -e "alter cell smtpToAddr=\'
[email protected]\'" Check up all settings at one place:
[celladmin@prolcel01 ~]# dcli -l root -g all_cells cellcli -e "list cell attributes name,smtpServer,smtpToAddr,smtpFrom,smtpFromAddr,smtpPort" prolcel01: cell01 Machine"
prolcel02: cell02 Machine"
Machine"
Machine"
STCEXCPMB02.xxxx.xxxx STCEXCPMB02.xxxx.xxxx STCEXCPMB02.xxxx.xxxx
[email protected]
"Proligence Test Database
[email protected]
"Proligence Test Database
[email protected]
"Proligence Test Database
[email protected]
"Proligence Test Database
[email protected]
"Exadata Cell 07"
25
STCEXCPMB02.xxxx.xxxx 25
STCEXCPMB02.xxxx.xxxx
[email protected]
"Proligence Test Database
25
[email protected]
prolcel07: cell07
[email protected]
25
[email protected]
prolcel06: cell06
"Proligence Test Database
25
[email protected]
prolcel05: cell05 Machine"
STCEXCPMB02.xxxx.xxxx
[email protected]
prolcel04: cell04
[email protected] 25
[email protected]
prolcel03: cell03 Machine"
STCEXCPMB02.xxxx.xxxx
[email protected]
25
After everything is set up properly, you may want to make sure the email set up is correct by running the alter cell validate command, across all the cells as shown below. [celladmin@prolcel01 ~]# dcli -l root -g all_cells cellcli -e "alter cell validate mail" If you get the email from these cells, then the emails have been configured properly.
Abbreviated Output You might see that the output from DCLI is not rather large since it shows the output from all the cells. It might be difficult to read, especially for scripting purposes. To address that problem, DCLI has another parameter -n, which simply shows OK after a successful execution and shows the cells where it was successfully executed. For instance, you can execute the email validation shown earlier with the -n option: [celladmin@prolcel01 ~]# dcli -l root -g all_cells -n cellcli -e "alter cell validate mail" OK: ['prolcel01', 'prolcel02', 'prolcel03', 'prolcel04', 'prolcel05', 'prolcel06', 'prolcel07', 'prolcel08']
Regular Expressions Sometimes you want to check something quickly but want to see only exceptions; not all output. For instance, suppose you want to find out which grid disks are inactive. Following command will show the status of the grid disks. [celladmin@prolcel01 ~]# dcli -l root -g all_cells cellcli -e "list griddisk" But it will list all the disks – active or inactive. With hundreds of grid disks, the output may be too overwhelming and less useful. Instead, you may want to see those ones that are inactive. The -r option allows you to enter a regular expression that will not be matched. In this case, we want to see the strings which are not “active”. We can write a command like the following. [celladmin@prolcel01 ~]# dcli -r '.* active' -l root -g all_cells cellcli -e "list griddisk" .* active: ['prolcel01', 'prolcel02', 'prolcel03', 'prolcel04', 'prolcel05', 'prolcel06', 'prolcel07', 'prolcel08'] prolcel01: PRORECO_CD_11_cell01 inactive It clearly showed that the grid disk PRORECO_CD_11_cell01 in cell prolcel01 is inactive. It’s a quick check on abnormal conditions.
Command Scripts You can place cellcli commands inside a script and call that script. Suppose you want to develop an error check script for CellCLI called err.dcl (the extension .dcl is not mandatory; it’s just convenient). Here is how the script looks like:
[celladmin@prolcel01 ~]# cat err.dcl cellcli -e list physicaldisk attributes errCmdTimeoutCount,errHardReadCount,errHardWriteCount,errMediaCount,errOtherCount,e rrSeekCount,errorCount where disktype='HardDisk' You saw earlier how to execute this script from CellCLI. You can execute this script from DCLI as well, using the -x option, as shown below: [celladmin@prolcel01 ~]# dcli -l root -g all_cells -x err.dcl prolcel01: 34:0 0 0 prolcel01: 34:1 0 0 prolcel01: 34:2 0 0 prolcel01: 34:3 0 0 … output truncated … prolcel08: 20:6 0 0 prolcel08: 20:7 0 0 prolcel08: 20:8 0 1 prolcel08: 20:9 0 0 prolcel08: 20:10 0 0 prolcel08: 20:11 0 0 Note how the error is shown in prolcel08 but it is buried under tons of other output, making it less readable and prone to overlook. Here is where the -r option (described in the last subsection) comes handy, to remove the lines containing “active”, as shown below: [celladmin@prolcel01 ~]# dcli -l root -g all_cells -r '.* 0' -x err.dcl .* 0: ['prolcel01', 'prolcel02', 'prolcel03', 'prolcel04', 'prolcel05', 'prolcel06', 'prolcel07', 'prolcel08'] prolcel08: 0 1 This resultant output is short and simple. Summary In summary, the dcli command allows you to execute commands (including cellcli) on other cell servers. The general structure of the command is # dcli Where commands could be CellCLI commands, e.g. cellcli –e list cell, or Linux commands like vmstat 2 2. Here are the most commonly used options and what they do. Optio n
Value Example Usage Expected after the Option
-c
Names of the cell(s)
-g
The file name -g all_cells where the cells are listed
Executes the command on the cells mentioned in the file all_cells.
-l
-l root The OS user that will execute the command
The default user is celladmin; but you can use any other user to use for remote ssh execution. Make sure the user has ssh equivalency across all the cells
-c dwhcel01,dwhcel02
What It Does
Executes the commands only on those cells.
where you run this command -n
Not Applicable
-n
This shows an abbreviated output instead of a long output from each command execution
-r
A regular expression
-r [*. active]
Suppresses the output that matches the regular expression
-t
Not Applicable
-t
Displays the cells where the command will run
-x
A script with executable commands
-x list.dcl
The script will be executed on the target cells
-k
Names of the cell(s)
-k dwhcel01,dwhcel02
Establishes the ssh user equivalency
-f
A filename
-f run.dcl
Copies the files to the other cells but does not execute them. It's useful for copying files and executing them later.
Conclusion The commands CellCLI and DCLI are used to manage the Exadata Storage Server, and most likely are only commands that you are not familiar with as a DBA. In this installment you saw the most useful commands and their example usage. In the next and final installment, you will learn how to use some of these and Oracle Enterprise Manager Grid Control to check on the various components and get detailed reports. > Back to Series TOC
Arup Nanda (
[email protected]) has been an Oracle DBA for more than 14 years, handling all aspects of database administration, from performance tuning to security and disaster recovery. He is an Oracle ACE Director and was Oracle Magazine's DBA of the Year in 2003.
Oracle Exadata Commands Reference
Part 4: Metrics and Reporting by Arup Nanda Learn how to use various metrics and reports available to measure the efficiency and effectiveness of your Exadata Database Machine environment. > Back to Series TOC (The purpose of this guide is educational; it is not intended to replace official Oracle-provided manuals or other documentation. The information in this guide is not validated by Oracle, is not supported by Oracle, and should only be used at your own risk.)
To keep a handle on the Oracle Exadata Database Machine’s reliability and efficiency you will need to measure several health metrics. Monitoring these metrics is likely to be your most common activity, but even so you would probably want a heads-up when something is amiss. In this final installment, you will learn how to check these metrics, either via the CellCLI interface or Oracle Enterprise Manager, and receive alerts based on certain conditions.
Metrics Using CellCLI First, let’s see how to get the metrics through CellCLI. To check the current metrics, simply use the following command: CellCLI> list metriccurrent It will show all the metrics, which quickly becomes impossible to read. Instead you may want to focus on specific ones. For example, to display a specific metric called GD_IO_RQ_W_SM, use it as a modifier. (If you are wondering what this metric is about, you will learn that shortly.) CellCLI> list metriccurrent gd_io_rq_w_sm GD_IO_RQ_W_SM PRODATA_CD_00_cell01 2,665 IO requests GD_IO_RQ_W_SM PRODATA_CD_01_cell01 5,710 IO requests GD_IO_RQ_W_SM PRODATA_CD_02_cell01 2,454 IO requests … output truncated … The metric shows you the I/O requests to the different cell disks. While this may be good for a quick glance at some single parameter, it’s not super-useful for checking up on all the other metrics. To get a longer list of metrics, use the detail option. CellCLI> list metriccurrent gd_io_rq_w_sm detail name: GD_IO_RQ_W_SM alertState: normal collectionTime: 2011-05-26T11:25:33-04:00 metricObjectName: PRODATA_CD_02_cell01 metricType: Cumulative metricValue: 2,456 IO requests objectType: GRIDDISK name: GD_IO_RQ_W_SM alertState: normal collectionTime: 2011-05-26T11:25:33-04:00 metricObjectName: PRODATA_CD_03_cell01 metricType: Cumulative metricValue: 2,982 IO requests objectType: GRIDDISK name: GD_IO_RQ_W_SM alertState: normal collectionTime: 2011-05-26T11:25:33-04:00 metricObjectName: PRODATA_CD_04_cell01 metricType: Cumulative metricValue: 1,631 IO requests objectType: GRIDDISK … output truncated … The output shows the name metric, the object on which this metric is defined (e.g. PRODATA_CD_02_cell01), the type of that object (e.g. grid disk), when the metric was collected, and the current value, among others.
The objects on which the metrics have been defined are wide ranging in types. For instance, here is the metric for rate of reception for I/O packets, which is defined on the object type Cell. CellCLI> list metriccurrent n_nic_rcv_sec detail name: N_NIC_RCV_SEC alertState: normal collectionTime: 2011-05-26T11:23:28-04:00 metricObjectName: cell01 metricType: Rate metricValue: 3.7 packets/sec objectType: CELL
Attributes What other information does current metric show? To know that answer, use the following command. CellCLI> describe metriccurrent name alertState collectionTime metricObjectName metricType metricValue objectType Note the attribute called alertState, which is probably the most important for you. If the metric is within the limit defined as safe, the alertState will be set to normal. You can use this command to display the interesting attributes where the alert has been triggered, i.e. alertState is non-zero: CellCLI> list metriccurrent attributes name,metricObjectName,metricType,metricValue,objectType > where alertState != 'normal' Alternatively you can select the current metrics on other types of objects as well. For instance, here is an example of checking the metrics on the interconnect. CellCLI> list metriccurrent attributes name,metricObjectName, metricType,metricValue,alertState > where objectType = 'HOST_INTERCONNECT' N_MB_DROP proddb01.xxxx.xxxx Cumulative 0.0 MB normal N_MB_DROP proddb02.xxxx.xxxx Cumulative 0.0 MB normal N_MB_DROP proddb03.xxxx.xxxx Cumulative 0.0 MB normal N_MB_DROP proddb04.xxxx.xxxx Cumulative 0.0 MB normal … outout truncated … As always, refer to the describe command to learn about the order of the attributes, since the output does not have a heading. You can also skip naming the attribute and just use ALL, which will show all the attributes. Let’s see the metrics for a cell. Since we are running it on cell01, the metrics of only that cell is shown: CellCLI> list metriccurrent attributes all where objectType = 'CELL' CL_BBU_CHARGE 93.0 %
normal
2011-05-26T11:37:10-04:00
cell01
Instantaneous
normal
2011-05-26T11:37:10-04:00
cell01
Instantaneous
normal
2011-05-26T11:37:10-04:00
cell01
Instantaneous
normal
2011-05-26T11:37:10-04:00
cell01
Instantaneous
CELL CL_BBU_TEMP
41.0 C
CELL CL_CPUT
%
CELL CL_FANS
2.4
12
CELL CL_MEMUT
%
normal
2011-05-26T11:37:10-04:00
cell01
Instantaneous
41
normal
2011-05-26T11:37:10-04:00
cell01
Instantaneous
normal
2011-05-26T11:37:10-04:00
cell01
Instantaneous
normal
2011-05-26T11:36:34-04:00
cell01
Instantaneous
normal
2011-05-26T11:37:28-04:00
cell01
Instantaneous
normal
2011-05-26T11:37:28-04:00
cell01
Rate
3.2
normal
2011-05-26T11:37:28-04:00
cell01
Rate
3.6
CELL CL_RUNQ
0.7
CELL CL_TEMP
25.0 C
CELL IORM_MODE
0
CELL N_NIC_NW
3
CELL N_NIC_RCV_SEC
packets/sec
CELL
N_NIC_TRANS_SEC packets/sec
CELL
Let’s examine the meaning of these metrics in some detail: CL_BBU_CHARGE
Battery charge on the disk controller
CL_BBU_TEMP
Temperature of the disk controller battery
CL_CPUT
CPU utilization
CL_FANS
Number of working fans
CL_FSUT
%age utilization of file systems
CL-MEMUT
%age of memory use
CL_RUNQ
The run queue
CL_TEMP
Temperature of the cell
IORM_MODE
I/O Resource Management mode in effect
N_NIC_NW
Number of interconnects *not* working
N_NIC_RCV_SEC
Rate of reception of I/O packet
N_NIC_TRANS_SEC
Rate of transmission of I/O packet
Speaking of current metrics, what are the names? You saw a few of them previously: N_MB_DROP, etc. To get a complete list, use the following command: CellCLI> list metricdefinition CD_IO_BY_R_LG CD_IO_BY_R_LG_SEC CD_IO_BY_R_SM CD_IO_BY_R_SM_SEC CD_IO_BY_W_LG CD_IO_BY_W_LG_SEC CD_IO_BY_W_SM CD_IO_BY_W_SM_SEC CD_IO_ERRS CD_IO_ERRS_MIN CD_IO_LOAD CD_IO_RQ_R_LG
CD_IO_RQ_R_LG_SEC CD_IO_RQ_R_SM CD_IO_RQ_R_SM_SEC CD_IO_RQ_W_LG CD_IO_RQ_W_LG_SEC CD_IO_RQ_W_SM CD_IO_RQ_W_SM_SEC CD_IO_ST_RQ CD_IO_TM_R_LG CD_IO_TM_R_LG_RQ CD_IO_TM_R_SM CD_IO_TM_R_SM_RQ CD_IO_TM_W_LG CD_IO_TM_W_LG_RQ CD_IO_TM_W_SM CD_IO_TM_W_SM_RQ CG_FC_IO_BY_SEC CG_FC_IO_RQ CG_FC_IO_RQ_SEC CG_FD_IO_BY_SEC CG_FD_IO_LOAD CG_FD_IO_RQ_LG CG_FD_IO_RQ_LG_SEC CG_FD_IO_RQ_SM CG_FD_IO_RQ_SM_SEC CG_IO_BY_SEC CG_IO_LOAD CG_IO_RQ_LG CG_IO_RQ_LG_SEC CG_IO_RQ_SM CG_IO_RQ_SM_SEC CG_IO_UTIL_LG CG_IO_UTIL_SM CG_IO_WT_LG CG_IO_WT_LG_RQ CG_IO_WT_SM CG_IO_WT_SM_RQ CL_BBU_CHARGE CL_BBU_TEMP CL_CPUT CL_FANS CL_FSUT CL_MEMUT CL_RUNQ CL_TEMP CT_FC_IO_BY_SEC CT_FC_IO_RQ CT_FC_IO_RQ_SEC CT_FD_IO_BY_SEC CT_FD_IO_LOAD CT_FD_IO_RQ_LG CT_FD_IO_RQ_LG_SEC CT_FD_IO_RQ_SM CT_FD_IO_RQ_SM_SEC CT_IO_BY_SEC CT_IO_LOAD CT_IO_RQ_LG CT_IO_RQ_LG_SEC
CT_IO_RQ_SM CT_IO_RQ_SM_SEC CT_IO_UTIL_LG CT_IO_UTIL_SM CT_IO_WT_LG CT_IO_WT_LG_RQ CT_IO_WT_SM CT_IO_WT_SM_RQ DB_FC_IO_BY_SEC DB_FC_IO_RQ DB_FC_IO_RQ_SEC DB_FD_IO_BY_SEC DB_FD_IO_LOAD DB_FD_IO_RQ_LG DB_FD_IO_RQ_LG_SEC DB_FD_IO_RQ_SM DB_FD_IO_RQ_SM_SEC DB_IO_BY_SEC DB_IO_LOAD DB_IO_RQ_LG DB_IO_RQ_LG_SEC DB_IO_RQ_SM DB_IO_RQ_SM_SEC DB_IO_UTIL_LG DB_IO_UTIL_SM DB_IO_WT_LG DB_IO_WT_LG_RQ DB_IO_WT_SM DB_IO_WT_SM_RQ FC_BYKEEP_OVERWR FC_BYKEEP_OVERWR_SEC FC_BYKEEP_USED FC_BY_USED FC_IO_BYKEEP_R FC_IO_BYKEEP_R_SEC FC_IO_BYKEEP_W FC_IO_BYKEEP_W_SEC FC_IO_BY_R FC_IO_BY_R_MISS FC_IO_BY_R_MISS_SEC FC_IO_BY_R_SEC FC_IO_BY_R_SKIP FC_IO_BY_R_SKIP_SEC FC_IO_BY_W FC_IO_BY_W_SEC FC_IO_ERRS FC_IO_RQKEEP_R FC_IO_RQKEEP_R_MISS FC_IO_RQKEEP_R_MISS_SEC FC_IO_RQKEEP_R_SEC FC_IO_RQKEEP_R_SKIP FC_IO_RQKEEP_R_SKIP_SEC FC_IO_RQKEEP_W FC_IO_RQKEEP_W_SEC FC_IO_RQ_R FC_IO_RQ_R_MISS FC_IO_RQ_R_MISS_SEC FC_IO_RQ_R_SEC
FC_IO_RQ_R_SKIP FC_IO_RQ_R_SKIP_SEC FC_IO_RQ_W FC_IO_RQ_W_SEC GD_IO_BY_R_LG GD_IO_BY_R_LG_SEC GD_IO_BY_R_SM GD_IO_BY_R_SM_SEC GD_IO_BY_W_LG GD_IO_BY_W_LG_SEC GD_IO_BY_W_SM GD_IO_BY_W_SM_SEC GD_IO_ERRS GD_IO_ERRS_MIN GD_IO_RQ_R_LG GD_IO_RQ_R_LG_SEC GD_IO_RQ_R_SM GD_IO_RQ_R_SM_SEC GD_IO_RQ_W_LG GD_IO_RQ_W_LG_SEC GD_IO_RQ_W_SM GD_IO_RQ_W_SM_SEC IORM_MODE N_MB_DROP N_MB_DROP_SEC N_MB_RDMA_DROP N_MB_RDMA_DROP_SEC N_MB_RECEIVED N_MB_RECEIVED_SEC N_MB_RESENT N_MB_RESENT_SEC N_MB_SENT N_MB_SENT_SEC N_NIC_NW N_NIC_RCV_SEC N_NIC_TRANS_SEC N_RDMA_RETRY_TM
You can use any of these metrics in the metricType. I am sure your next question is on the description of these metrics. To know more about each metric, issue the command with the name and the detail modifiers: CellCLI> list metricdefinition cl_cput detail name: CL_CPUT description: "Cell CPU Utilization is the percentage of time over the previous minute that the system CPUs were not idle (from /proc/stat)." metricType: Instantaneous objectType: CELL unit: % Object Type Not all metrics are available on all objects. For instance the temperature is a metric for cells but not the disks. Note the objectType attribute in the output above; it shows the type of the object. You can learn about metrics on a specific type of object. First, see all the attributes you can choose: CellCLI> describe metricdefinition name
description metricType objectType persistencePolicy unit This will allow you to use attributes all keywords and let you understand the heading of the output. CellCLI> list metricdefinition attributes all where objecttype='CELL' CL_BBU_CHARGE
"Disk Controller Battery Charge"
CL_BBU_TEMP
"Disk Controller Battery
Instantaneous Temperature"
CELL
%
Instantaneous
CL_CPUT
CELL
"Cell CPU Utilization is the percentage of time over the previous minute that the system CPUs were not idle (from
/proc/stat)."
Instantaneous
CELL
%
CL_FANS
"Number of working fans on the
CL_MEMUT
"Percentage of total physical memory on the cell that is currently
cell" used"
Instantaneous Instantaneous
CELL
CL_RUNQ
CELL
Number
%
"Average number (over the preceding minute) of processes in the Linux run queue marked running or uninterruptible (from
/proc/loadavg)."
Instantaneous
CL_TEMP
CELL
Number
"Temperature (Celsius) of the server, provided by the
BMC"
Instantaneous
CELL
C
IORM_MODE
"I/O Resource Manager objective for the
N_NIC_NW
"Number of non-working
cell"
Instantaneous
CELL
interconnects"
Instantaneous
N_NIC_RCV_SEC second"
CELL
Number
"Total number of IO packets received by interconnects per
Rate
CELL
N_NIC_TRANS_SEC second"
Number
packets/sec
"Total number of IO packets transmitted by interconnects per
Rate
CELL
packets/sec
Using this command you can get the description on any metric. Some of the metric values are 0. Let’s see all metrics of Grid Disks which are bigger than 0: CellCLI> list metriccurrent attributes all where objectType = 'GRIDDISK' > and metricObjectName = 'PRODATA_CD_09_cell01' > and metricValue > 0 GD_IO_BY_R_LG
normal
3.9MB
2011-05-26T11:38:34-04:00
PRODATA_CD_09_cell01
Cumulative
2011-05-26T11:38:34-04:00
PRODATA_CD_09_cell01
Cumulative
2011-05-26T11:38:34-04:00
PRODATA_CD_09_cell01
Cumulative
2011-05-26T11:38:34-04:00
PRODATA_CD_09_cell01
Cumulative
2011-05-26T11:38:34-04:00
PRODATA_CD_09_cell01
Cumulative
2011-05-26T11:38:34-04:00
PRODATA_CD_09_cell01
Cumulative
2011-05-26T11:38:34-04:00
PRODATA_CD_09_cell01
Cumulative
2011-05-26T11:38:34-04:00
PRODATA_CD_09_cell01
Cumulative
GRIDDISK GD_IO_BY_R_SM
normal
29.3MB
GRIDDISK GD_IO_BY_W_LG
normal
797MB
GRIDDISK GD_IO_BY_W_SM
normal
73.3MB
GRIDDISK GD_IO_RQ_R_LG
IO requests
normal
GD_IO_RQ_R_SM
normal
1,504 IO requests
GRIDDISK
GD_IO_RQ_W_LG
normal
3,230 IO requests
GRIDDISK
GD_IO_RQ_W_SM 3,209 IO requests
4
GRIDDISK
normal GRIDDISK
Current metrics are like the pulse of the cell – they give you the health and effectiveness of the cell at that time.
Metrics History
Sometimes you may be interested in the history of the metrics. For instance you may want to get an idea about the trending of the values. Use the following command: CellCLI> list metrichistory It will get you everything and in fact the output may not be practical. Instead, you may want to examine metrics of a specific object only, since the metrics could be highly context relative. Here is an example where you can see the history of all the metric values for the cells. CellCLI> list metrichistory where objectType = 'CELL' IORM_MODE cell01 0 2011-0526T12:59:39-04:00 CL_BBU_TEMP cell01 41.0 C 2011-0526T13:00:10-04:00 CL_CPUT cell01 0.6 % 2011-0526T13:00:10-04:00 CL_FANS cell01 12 2011-0526T13:00:10-04:00 CL_MEMUT cell01 41 % 2011-0526T13:00:10-04:00 Don’t know what the columns are for? Just give the command describe metrichistory to see the attributes. While the output shows the history of metrics, it’s a little difficult to parse. You may want to examine a single statistic, not a bunch of them. The following example shows the history of the temperature of the cell. CellCLI> list metrichistory where objectType = 'CELL' > and name = 'CL_TEMP' CL_TEMP cell01 25.0 C 2011-05-26T13:00:10-04:00 CL_TEMP cell01 25.0 C 2011-05-26T13:01:10-04:00 CL_TEMP cell01 25.0 C 2011-05-26T13:02:10-04:00 CL_TEMP cell01 25.0 C 2011-05-26T13:03:10-04:00 CL_TEMP cell01 25.0 C 2011-05-26T13:04:10-04:00 CL_TEMP cell01 25.0 C 2011-05-26T13:05:10-04:00 … output truncated … Two of the often forgotten features of CellCLI is that you can invoke it with the –x option, which suppresses the banner, and the –n option, which suppresses the command line. # cellcli -x -n -e "list metrichistory where objectType = 'CELL' and name = 'CL_TEMP'" CL_TEMP prodcel01 24.0 C 2011-05-27T02:00:47-04:00 CL_TEMP prodcel01 24.0 C 2011-05-27T02:01:47-04:00 CL_TEMP prodcel01 24.0 C 2011-05-27T02:02:47-04:00 … output truncated … This output can be taken straight to a spreadsheet program for charting or other types of analysis.
Alerts Now that you learned about metrics, let’s see how you can use them to alert you when something happens. The Exadata Database Machine comes with a lot of predefined alerts out of the box. To see them use the following command. To get more information on them, use the detail modifier. CellCLI> list alertdefinition detail name: ADRAlert alertShortName: ADR alertSource: "Automatic Diagnostic Repository" alertType: Stateless description: "Incident Alert" metricName: name: HardwareAlert alertShortName: Hardware alertSource: Hardware
alertType: Stateless description: "Hardware Alert" metricName: name: StatefulAlert_CD_IO_ERRS_MIN alertShortName: CD_IO_ERRS_MIN alertSource: Metric alertType: Stateful description: "Threshold Alert" metricName: CD_IO_ERRS_MIN name: StatefulAlert_CG_FC_IO_BY_SEC alertShortName: CG_FC_IO_BY_SEC alertSource: Metric alertType: Stateful description: "Threshold Alert" metricName: CG_FC_IO_BY_SEC … output truncated … The alerts are based on metrics explained earlier. For instance, the alert StatefulAlert_CG_FC_IO_BY_SEC is based on the metric CG_FC_IO_BY_SEC. There are a few alerts which are not based on metrics. Here is how you can find them: CellCLI> list alertdefinition attributes all where alertSource!='Metric' ADRAlert ADR "Automatic Diagnostic Repository" Stateless "Incident Alert" HardwareAlert Hardware Hardware Stateless "Hardware Alert" Stateful_HardwareAlert Hardware Hardware Stateful "Hardware Stateful Alert" Stateful_SoftwareAlert Software Software Stateful "Software Stateful Alert" The next step is to define an alert based on a threshold. Here is how you can define a threshold on the metric CD_IO_ERRS_MIN on database called PRODB. You want the alert to be fired when the value is more than 10. CellCLI> create threshold cd_io_errs_min.prodb comparison=">", critical=10 Threshold DB_IO_RQ_SM_SEC.PRODB successfully created When an alert triggers, the cell takes the action on the notification schedule – it either sends an email or an SNMP trap, or both. Here is an example of an alert received via email. It shows that the cell failed to reach either the NTP or DNS server.
You can modify the threshold: CellCLI> alter threshold DB_IO_RQ_SM_SEC.PRODB comparison=">", critical=100 Threshold DB_IO_RQ_SM_SEC.PRODB successfully altered And, when not needed, you can drop the threshold. CellCLI> drop threshold DB_IO_RQ_SM_SEC.PRODB Threshold DB_IO_RQ_SM_SEC.PRODDB successfully dropped When you drop the threshold, the alert (if generated earlier) will be cleared and new alert is generated informing that the threshold was cleared. Here is an example email with that information.
Using Grid Control As you learned previously, you can administer the Exadata Database Machine in several ways: using the command-line tool CellCLI (or a number of cells at the same time by DCLI), using SRVCTL and CRSCTL, and via plain-old SQL commands. But the easiest approach, hands down, is to use Oracle Enterprise Manager Grid Control. The graphical interface simply makes the command interface intuitive and easy to read. If you already have a Grid Control infrastructure, it makes the decision very easy – you just add the Database Machine to it. If you don’t have Grid Control, perhaps you should seriously think about it now. Setup To manage the Database Machine via Grid Control, you need:
•
A plugin for storage server management for GC (download from http://www.oracle.com/technetwork/oem/grid-control/downloads/system-monitoring-connectors082031.html)
•
An agent installed in each of the compute nodes of DBM. No agent need be installed on the storage cells.
•
To configure access to the cells from the Oracle Management Server console machine
Let’s examine each approach in detail. The plugin is a jarfile you download and keep on the OMS server. The grid control agents are installed on the database compute nodes the same way you would have done for a normal database server. You can either push the agents from the Grid Control console, or download the agent software on the database compute nodes and install there. During the installation you will be asked the address and port number of the OMS server, which will complete the installation. The storage plug-in is different. This is not an agent on the storage cells; rather it’s installed as a part of the OMS server. So you need to download the plugin (which is a file with .jar extension) to the machine on which you launched the browser (typically your desktop), not the storage cells. After that, fire up the Grid Control browser and follow the steps shown below.
1. Go to the Setup screen, shown below:
2. 3. 4. 5. 6. 7. 8.
From the menu on the left, choose Management Plug-Ins. You need to import the plug-in to OMS. Click on the Import button. It will ask for a file name. Click on the button Browse, which will open the file explorer. Select the jarfile you just downloaded and click OK. The jarfile is actually an archive of different plug-ins inside. Choose the Exadata Storage Server Plugin. Press the OK button. You will be asked to enter preferred credentials. Make sure the userids and passwords are correct.
9. Click on the icon marked Deploy. 10. Click on the button Add Agents. 11. Click on Next and then Finish. 12. From the top bar menu (shown below) click on the hyperlink Agents. 13. Select the agent where you deployed the system management plug-in.
14. Go to the Management Agents page. 15. Select Oracle Exadata Storage Server target type from the drop down list. 16. Click on Add. 17. The screen will ask for the management IP of the storage server. Enter the IPs.
18. Click on the Test Connection button to ensure everything is working. 19. Click on the OK button. That’s it; the storage servers are now ready to be monitored via Grid Control.
Basic Information Once configured, your Exadata Database Machine shows up in Grid Control. The database compute nodes show up as normal database servers and the cluster shows up as a normal cluster database; there is nothing Exadataspecific in nature on those screens.
You may already be familiar with the normal Oracle RAC database management features on Grid Control, which applies to Exadata compute nodes as well. In this article we will assume you are familiar with the database management via Grid Control. The real benefit comes in looking at the storage cells as an alternative to CellCLI. To check storage cells, go to Homepage > Targets >All Targets. In the Search dropdown box choose Oracle Exadata Storage Server and press Go. The resulting screen that comes up is similar to the picture shown below. Note the names have been erased.
This is a full rack Exadata so there are 14 cells, or storage servers named with a prefix _Cell01 through _Cell14. Clicking on each of the hyperlinked cell names takes you to the information screen of the respective cell (also known as Storage Server). Let’s click on cell#2. It brings up the cell details similar to a screen shown below:
This screen shows you three basic but very important metrics:
•
CPU Utilization %-age
•
Memory Utilization %-age
•
Temperature of the server
The screen gives only a glimpse of these three metrics for the last 24 hours or so. Note that memory utilization has been constant, which is pretty typical. Since this is a storage cell, the only software that runs here is Exadata Storage Server, not the database sessions which tend to fluctuate in memory usage. The temperature has been pretty steady but spiked a little at around 6AM. The CPU however may show a wide fluctuation because of the demand on the ES software as a result of cell offloading (described in detail inPart 1). If you click on CPU Utilization, you will see a dedicated screen for CPU utilization as shown below.
It shows a more detailed graph on the CPU busy-ness across a more granular scale. You can choose to get the refresh frequency of the metric by choosing from the drop-down menu View Data near the top right corner. Here I have chosen "Real Time: 5 Minute Refresh." It will get the data in the real time but refresh only every 5 minutes. That is why you will notice the graph is non-smooth. You can also choose a longer period such as “last 7 days” or even “last 31 days” but that information is no longer real time. You can also choose the same information from Reports (described later in this installment). Clicking on Temperature and Memorygraphs will provide similar data. Cell Information Since the cell contains hard drives, which are mechanical devices and generate a lot of heat, it will fail if the temperature is too high. The cells contain fans to force the hot air out and to reduce the temperature. There are 12 fans in each cell. Are they working? There are two power supplies in the cell for redundancy. Are both working? To know the answer to these questions and get other information on the cell, click on the hyperlink View Configuration to bring up a screen like the following.
The information shown here is pretty similar to what you would have seen in the list cell command in CellCLI. Let’s examine some of the interesting information on this screen and why you would like to know about them:
•
Status – of course you want to know if this cell is even online and servicing traffic.
•
Fan Count – number of working fans
•
Power Count – the number of working power supplies (there should be two)
•
SMTP Server – the email server that is used to send emails. Very important for alerts.
•
IP Address – IP of the cell
•
Interconnect Count – the number of cell interconnects. Default is three.
•
CPU Count – the number of CPU cores.
This is just a summary of the cell. The objective of the cell is to provide a storage platform for the Exadata Database Machine. So far, we have not seen anything about the actual storage in the cell. To know about the storage in the cells, look further down the page. There are five sections:
•
Grid disks
•
Cell disks
•
LUNs
•
Physical disks
•
I/O Resource Manager
Note the set of 5 hyperlinks toward the top of the screen that will direct you to the appropriate section:
Instead of looking at the sections in the way they have been laid out, I suggest you look in the order they are created. For instance a cell contains physical disks, from which LUNs are created, from which cell disks are created, from which grid disks are created. Finally, IORM (I/O Resource Manager) is used on the disks. Let’s look at them in the same logical order. Physical Disks To know about the physical disks available in the cell, this is the section to look at. Here is a partial screenshot.
If this looks familiar, it’s because this is formatted output from the CellCLI command LIST PHYSICALDISK DETAIL or LIST PHYSICALDISK ATTRIBUTES. The important columns here to note are:
•
LUN/s – the LUN which is created on this physical disk
•
Error Count – if there are any errors on these physical disks
•
Physical Interface – SAS for hard disks, ATA for flash disks. Some older Exadata Database Machines may have SATA hard disks and this column will show “sas”.
•
Size – The size in GB of the physical disks
•
Insert Time – the date and timestamp when these records were recorded in the repository.
LUNs Next, let’s look at the LUNs in the cell by clicking on the Cell LUN Configuration hyperlink.
Again, this is the graphical representation of the LIST LUN ATTRIBUTES command. Note that the flash drives are also listed here, toward the bottom of the output. They are named with a prefix FD in the Cell Disk, unlike “CD” in case of regular SAS hard disks. LUNs are created from hard disk partitions, which are presented to the host (the storage cell) as a device. The device ID shows up here, along with the cell disks created on the LUN. The two columns that you should pay attention to are “Status” and “Error Count”. If you see just 10 LUNs, click on the dropdown box and select all 28. Cell Disks Cell disks are created from the physical disks. In CellCLI, you got the list by using the LIST CELLDISK command. In Grid Control, clicking on the hyperlink Celldisk Configuration will give show the list of cell disks in a graphical manner, similar to one shown below. Like the previous section, click on the drop-down list to choose “All 28” to show all 28 cell disks on the same page. Again, you should pay attention to “Error Count” and “Status” columns.
Grid Disks Grid Disks are created from the cell disks, and are used to build the ASM diskgroups. Obviously, these are the actual building blocks of the storage the ASM instance is aware of. Typically there is a one-to-one relationship between cell disk and grid disk, but if there is not one in your case, you may see less available space in your ASM diskgroup. Clicking on the Griddisk Configuration hyperlink brings up the screen similar to the following:
The key columns in this screen to look at are:
•
Status – if the grid disk is active. If inactive, it’s offline and ASM can’t use it.
•
Size – does the size sound right? Or was it created with less size from the cell disk? In that case the ASM instance will see that reduced size as well.
•
Error Count – have there been errors on this grid disk.
This brings us to the end of the basic building blocks of the storage cells, or storage servers. Using these graphical screens or the CellCLI commands you can get most of the information on these building blocks. Now let’s get on to some of the more complex data needs: to gather the performance and management metrics on these components. For example, is the cell disk performing optimally, or are there any issues with the grid disk that may result in data loss? Metrics The best way to examine the metrics for these components is to explore them in the dedicated Metrics page in Grid Control. Note the set of hyperlinks toward the bottom of the page and click on All Metrics. It will bring up a screen as shown below.
Remember, metrics are gathered and stored in the OMS server and then presented as needed. Since they are stored in the OMS server, they affect the performance of the Exadata Database Machine little or none at all. The screen above shows the frequency these metrics are collected (15 minutes, 1 minute, etc.). Some of the metrics are real time (flash cache statistics for example); others do not have any schedule (such as error messages and alerts). The collection frequency is displayed under the column “Collection Schedule”. When the metrics are collected, they are uploaded to the OMS server’s database. The screen above also shows how soon the metrics are uploaded after collection (the column “Upload Interval”), along with the date and time the last upload occurred (“Last Upload”). Metrics can also be used to trigger alerts. For instance, if the cell offload efficiency falls below a certain threshold, you can trigger an alert. We will see how these alerts are set up later but the alerting threshold is shown in this screen as well, under the column “Threshold”.
The screen shows the metrics collected by Grid Control and the frequency of the collection. If you want, you can see all the sub categories and specific metric names by clicking on Expand All. Let’s focus on only one category – Category Statistics. Click on the “+” before the category to show the various metrics; you will see a screen similar to the following:
Click on Category Small IO Requests/Sec.
Click on the eyeglass icon under the column “Details”.
Like all the other screens you saw earlier, you can choose a different refresh frequency by choosing the appropriate value from the drop-down menu “View Data”. Alternatively, you can choose historical records by selecting Last 24 hours, or Last 7 days, etc. Reports Reports are similar to screens reporting metrics but with some important differences. Some reports could be better for viewing certain metrics but the most valuable use of reports is to compare metrics across several components at a glance. From the main Enterprise Manager page, choose the Reports tab from the ribbon of tabs at the top. Click on the Report tab and scroll down several pages to a collection of reports named “Storage”, as shown below:
This section shows all the metrics you might have seen earlier, but with a major difference: The reports are organized as independent entities, which can report the data on any component -- not driven from the details screen of the component itself. For instance, click on the hyperlink Celldisk Performance. It brings up a screen asking you to choose the cell disk you are interested in rather than choosing the cell disk screen first and then going to the performance metrics of that cell disk. You can choose a cell disk from the list by clicking on the flashlight icon (the list of values) and it brings up a screen as shown below.
If you click on one of the hyperlinked cell disks Cell Disk, you will see the data for that cell disk.
Grid Disk Performance As you learned in Part 2 of this series, the grid disks are built from the cell disks and then used for ASM diskgroups. Thus the performance of the grid disks will directly affect the performance of the ASM diskgroups, which in turn will affect database performance. So it’s important to keep a tab on the grid disk performance and examine it if you see any issues in the database. From the report menu shown earlier, go to Storage > CELL > Grid Disk Performance. It will ask you to pick a cell from the list. Choosing Cell 02 will bring up a screen similar to this.
The other important metric to examine is host interconnect performance:
Doing Comparisons Sometimes you wonder how one component such as a cell disk is doing compared to other cell disks. The comparison is a very neat feature in the Grid Control. First get to the page of the metric you are interested in:
Click on the hyperlink just below Related Links shown as Compare Objects Celldisk Name/Cell Name/Realm Name.
Then click on the OK button. The comparison will appear in the screen similar to the one shown below:
The comparison shows that cell disk CD_00_cell01 has a higher write throughput compared to the other two. Metrics on Realms A realm is a set of components enclosed within a logical boundary. Realms are used to separate systems for different usage – for instance you may create a realm each for database A, database B, etc. By default there is a single realm. Since all the cells belong to the realm, metrics for a realm go across the cells and are not limited to the current cell alone. Let’s see an example. If you pull up the LUN Configuration report, you will see the following:
It shows 28 records since there are 28 LUNs in this cell. The scope of this report is the current cell, not the others. When you pull up the Realm LUN Configuration, it will show the LUNs of all the cells, as shown below. Note the difference: 392 rows instead of 28. All the LUNs from all the cells have been shown here.
Choosing realms for reports can allow you to get the picture for a specific realm immediately. If there is only one realm, then all the cells are pulled together in the report. Consider a very important report – Realm Performance, shown below.
It shows you the metrics across all the cells in that realm. This is an excellent way to quickly compare various cells to see if they are uniformly loaded. On the same line of thought, you may want to compare performance of the components of the cells, not just the cells. Choosing Realm Celldisk Performance from the View Report dropdown menu shows the performance of the cell disks across all the cells, not just that cell.
However, with the sheer amount of data in the report (392 rows), it may not be as useful. A better option may be is to compare the Cell Disk #1 of all the cells. You can do that by using a filter in the Celldisk field.
This shows the performance of the first cell disks of all the cells. From the above output, it is clear that Cell 05 is seeing some action while the others are practically idle. Since you don’t operate at the cell level, it can be assumed that the data distribution may not be uniform. Cell #5 may happen to have the most number of storage blocks.
Conclusion In this installment you learned how to examine metrics from the storage cells using two different interfaces: the command-line tool CellCLI and Enterprise Manager Grid Control. Both have their own appeals. While the visual advantage of the Grid Control is undeniable, the command line tool may be useful in developing scripts and repeatable processes. The Exadata Database Machine comes with a lot of predefined alerts that can be
configured via thresholds to make sure they trigger when the metric values fall outside the pre-specified boundary conditions. This brings us to the end of this series. I hope you developed enough skills in this series to make the transition from DBA to DMA easily and quickly! > Back to Series TOC
Arup Nanda (