Ercisson Comm Detail

September 20, 2017 | Author: mamshadmm | Category: N/A
Share Embed Donate


Short Description

ericsson commands...

Description

TO FIND RALT rlmbp:id=all; rlmtp:id=all,cell=46481; rlmbi:id=50,code=34,gs=3,lang=1,NUMPAGES=1,MODE=MML; RLMBI:ID=50,CODE=34,GS=3,CELL=46481; RLMBC:ID=50,CODE=34,GS=3,TEXT="HABTOOR GRAND RESORT & SPA"; RLMTI:ID=50,CODE=34,GS=3,REP=60; RLMTP:ID=ALL,CELL=46481; RLMBE:CELL=46481,ID=50,CODE=21,GS=3; ............................................................. RLUMC:CELL=11181,ADD/"REM",UMFI=10612-405-NODIV; RLNRI/"E":CELL=11181,CELLR=U28272,SINGLE; .................................................. OSF-Report directory:/home/cfd/om ..................................................... STDEP:DEV=RBLT-673; BLODI:DEV=RBLT-673;

##cna export## cna_export NW=AXE, MSC=all, MSC_REF=none, BSC=all, BSC_REF=none, SITE=all,SITE_REF=none, CELL=all, CELL_REF=bsic_bcch_lac, OUTPUT=st2 ....................................................................... ###CBC Definition#### rlmtp:id=all rlmbp:id=all,cell=all rlmbi:cell=1234,id=50,code=1,gs=3,mode=mml rlmbc:cell=1234,id=50,code=1,gs=3,text="mahmood" rlmti:id=50,code=1,gs=3,rep=60 rlmbe:cell=1234,id=50,code=1,gs=3 rlmte:id=50,code=1,gs=3 ........................................................................ Repei:emg=sabkhatalhairya,str=a; remei:emg=sabkhatalhairya,pcb=strp,mag=str-a; recei:emg=sabkhatalhairya,str=a; ....................................................................... EXRPP:RP=ALL TO PRINT ALL RP DEV repri:rp=106; remri:rp=106,pcb=RPPS1; recri:rp=106; ......................................................................... RXMSP:MO=RXOTRX-27-0&&-11;

RXMFP:MO=RXOCF-21; RXELP:MO=RXOTG-27; ......................................................................... . RLSTP:CELL=ALL,STATE=HALTED; ......................................................................... .. IMLIT:SPG=0 SDTDP:RPTID=132,INT=15,OBJTYPE=CLSDCCH,OBJ=CELL ID SDTDP:RPTID=130,INT=15,OBJTYPE=CELTCHF,OBJ=CELL ID END ......................................................................... . RXMSP:MO=RXOTRX-12-0&&-11; ......................................................................... . TO CHECK ALL STATE SD TCH SUC IMLIT:SPG=0 SDTDP:INT=15,RPTID=230; END ..................................................... TCH 130 ............................ SDDCH 132 ......................... HOW TO CHECK TCH SET+HO% AND THE CONG

IMLIT:SPG=0; SDTDP:RPTID=130,INT=15,OBJTYPE=CELTCHF,OBJ=45022; END; ................................................................. FOR FORLOOP RELES rxmop:mo=rxotg-; syfri:fid=h'000-h'890,filenum=1,block=rxotgd,ind=tg#; ................................................................ NTCOP:SNT=ETRALT STDEP:DEV=233&&3234; ......................................................................... .......

HOW TO RESET THE LINK IN CASE OF NETWORK SYNCHRONIZATION FAULT? EXSCP:NAME=ALL; ............................................................. RP SUPRATION: ................................................................. RXMDP:MO=RXOTRX-TG-0&&-11; RADRP:DEV=RHDEV-#; FCRWS:RP=23,WS=SEP; SELECT RP ONE BY ONE IF MORE THAN ONE RP BLRPE:RP=23; TO DEBLOCK THE RB AND TRX WILL USE DIFFRENT DEV ................................................................. TO CHECK UP LINK QUALITY IMLIT:SPG=0; SDTDP:RPTID=126,INT=1,PER=PREV; END; ......................................................................... ...... TO CONNECT THE TG TO THE CELL RXTCI:MO=RXOTG-#,CELL=43214,chgr=0; RXTCE:MO=RXOTG-#,CELL=4342; TO DISSCONNECT THE TG FROM CELL ........................................................................ GSSTP; TO CHECK THE TSM ........................................................................ RRGBP; TO CHECK ALL GB LINK RLGRP; TO CHECK GB LINK IN THE CELL ........................................................................ RXPLI:MO=RXOTG-#,UC; TO RELOAD THE SOFT WARE TO LOAD THE NEW SOFT WARE.....RXMSC:MO=RXOTG-71,SWVER=B1922R002H; AFTER CHANGE WE SHOUD DO ....RXPLI:MO=RXOTG-#,UC; ......................................................................... .. DTSTP:DIP=ALL; TO CHECK ALL DEVICE BLODI: TO BLOCK THE DEVICE ......................................................................... ...... rxapp:mo=rxotg-; to check rblt dev which cell using rxape:mo=rxotg-,dcp=; to delet the rblt dev rxapi:mo=rxotg-,dcp=; to add the dev; IN CASE OF COSENTRATION EVRY 3 TRU USE ONE DCP FOR SYNGRONYSATION AND 2D DCP FOR SPEECH .....WITH OUT COSENTRATION EACH TRU USE 3 DCP.EACH RBLT HAVE 28 DCP ......................................................................... ............... rxmoi:mo=rxotg-; to define rxmoe:mo=rxotg-; to un define ......................................................................... ...................................

HOW TO TAKE BACKUP SYBUE; SYBUP:FILE; SETUP 1 AT WILL TAKE AROUND 20 MIN AND WE WILL GET ON CHA BACKUP INFORMATION OUT PUT EXECUTED ; SYTUC; SYBUI:DISC SETUP 2 AT WILL TAKE 30 SECOND ......................................................................... ................................... rxmsc:mo=rxotg-#,swver=b1921r0086; to change software version in case if site on service after that we will do rxpli. rxpli:mo=rxotg-#,uc; to load the software ....................................................... rxmoc:mo=rxotg-#,swver=b1921r0086; we used in case if the site out of service and no need to load the soft ware it will load when we deblock. rxmoc:mo=rxocf-#,swver=b1921r0086 or default ; rxmoc:mo=rxotrx-30-1-#,swver=b1921r0086 or default ; rxmoc:mo=rxotrx-30-2,swver=b1921r0086 or default ; rxmoc:mo=rxotrx-30-3,swver=b1921r0086 or default ; rxmoc:mo=rxotrx-30-4,swver=b1921r0086 or default ; rxmoc:mo=rxotrx-30-5,swver=b1921r0086 or default ; ....in service ....deblock ......................................................................... .......................... rllhp:cell=33454; to check layerthreshod .layerhyst.psstemp.ptimtemp.layer rllhc:cell=4562,layerthrshod=45; this coomand to change all this parametars ................................................................... rlcpp:cell=; to print BSPWRB BSPWT MSTXPWR. RLCPC:CELL=, BSPWT=12.....TO CHANGE THE PRAMETER .................................................................. RLSSP:CELL= 21312; TO PRINT CCHPWR CRH DTXU RLSSC:CELL= TO CHANGE THIS PARAMETER ...................................................................... RLMFP:CELL=32; TO CHECK THE ACTIVE AND IDEL LIST. RLCFP:CELL= TO SEE THE FREQUNCY THAT CONNECTED TO THE CELL rlccc:cell=4256,sdcch=2or3or4,chgr=0 or 1; ......................................................................... ............. rlcfi:cell=4646,dchno=17; to add freqency rlcfe:cell=4324,dchno=45; to delet frequency if more than on chanell group we have to to writ channel group no after frequency . ................................................... GSSTP:TSM=12-B TO SEE THE STATE OF TSM GSBLI:TSM= TO BLOCK THE TSM GSTEI:TSM= TO TEST THE TSM GSBLE:TSM= TO DEBLOCK THE TSM

......................................... to check the pannel with nark to start allti:ali=0; for end allte:ali=0; ........................................ ntbli: to block the snt ntble:to dblock the snt stdep:dev=; to check the device ntcop:snt= to print the dev; rrtbi:dev=,force; to block the device rrtbe:dev= to d block the dev ........................................ EXRPP:RP=98 TO CHECK THE STATE OF RP BLRPI:RP=; BLOCK THE RP BLRPE:RP=; DBLOCK ......................................... RXESE: TO PUT OUT OF SERVICE RXESI: TO PUT IN SERVICE ..................................... ALLIP:ALCAT=PROC; RXMOP:MO=RXOTG-;

TO CHECK RP FAULT TO SEE THE SOFT WARE NAME

............................................................ C7LTP:LS=ALL; TO CHECK ALL C7 LINK. EXSCP:NAME=ALL TO CHECK SLC UNDER WHICH RALT C7SUE:LS=2-563; TO BLOCK C7 LINK C7SUC:LS=2-456,DMI=0,ACL=A1,LVA=2; TO CHANGE THE ALARM LEVEL C7SUI:LS=2-876; TO D BLOCK THE C7LINK ................................................................. OUT STANDING FAULT OPS...FILE OPEN...HOME...CFD.....DIALY FAULTS.....RUN FILE FROM TOP. OPEN FROM EXEL...SELECT 10.16.40.129...HOME ..CFD...OM...04021006 YEAR MONTH DATE TIME....COPY PAST TO OUT STANDING. .................................................................. DIALY FAULT SUMMARY 1-first we run file from alb and saved in the path or folder name /home/cfd/dfs THE FILE IS ON /HOME/CFD/DFS >PWD >CD space .. >CD cd/dfs >CD DFS >DFS ENTER INPUTFILE NAME MO_DATE MO-091204 in input file we will save the which we putit on alb

ENTER OUT FILE NAME DFS_DATE from exel-home-cfd-dfs

we will put the name which we will open it

FROM EXCEL HOME..CFD...DFS and writ file name after that copy this file to daily fault summrey master then past that on input after that writ mouse and refrish the dialy fault summery will be on shared folder -omcdxb&aan-reportdialey fault summery ......................................................................... .................................... FORMELA FOR SERVICE INTRUPTION (=G+H-E-F) ENDDATE+ENDTIME-STARTDATESTARTTIME. ......................................................................... .................. IN CASE OF CP FAULT 1-REPCI 2-REMCI: PCB=POWC,MAG=CPU-B; 3-RECCI ............................................................. NTSTP:SNT=ALL........ TO PRINT ALL SNT ......................................................................... .... .......................................... TCH AND SDH LIMIT VALUE 1-IF NUMBER OF DCH FREQUENCY 1 OR 2 HE SDCCH WILL BE 1 IF 3 OR -4-5-6 THE SDCCH WILL BE 2 IF 7 OR 8-9-10-11-12- THE SDCCH WILL 3. 2-SDCCH LIMIT VALUE= NUMBER OF SDCCH X 8. 3-TCHFR LIMIT VALUE=NUMBER OF DCH X 8 - SDCCH -1. 4-TCHEFR=TCHFR VALUE/2 -4. ...................................................................... IMLCT:SPG=0; MCSAP:FILE=TRLOG1FILE,COMMAND="fcrws",SDATE=20040410,STIME=0000,EDATE=200 40410,IO1=ALL; ...... to cheack the command in the bsc. END; ......................................................................... ....................................... RX DIVERSITY LOST: WE HAVE TWO RX IN EACH CELL THEIS TWO RX TRY TO GET BEST DIVERSITY FOR CALL IF THIS RX DIDNT RECIVE GOOD SIGNAL THAT MEAN WE HAVE PROBLEM ON RX.

RF LOOP TEST: NORMALY DXU CHECK DO RF TEST TO TRX AND ALL HARDWARE UNDER DXU IF ONE IF THIS HARDWARE HAVE PROBLEM IT WILL GIVE AS RF LOOP TEST FAULT. NON-VOLATILE MEMORY CORRUPTED: IN THE DXU WE HAVE MEMORY CALLED VOLATILE IN THIS INFORMATION CORUPT WE WILL GET THIS ALARM SO AFTER DXU RESET IT WILL CLEAR. VSWR: IT'S LIKE RATIO THE SIGNAL WILL GO FROM BTS TO ANTENA ON 1 DB AND IT WILL REFLACT BACK TO BTS THE RATIO , IT'S SHOUD NOT BE BIG DIFFRENT BETWEEN SENDING AND RECIVING IF THERE WAS BIG DIFFRENT WE WILL GET THIS ALARM. ......................................................................... ............................. HOW TO CHECK IF LINK IS CASSCATED OR NOT?? GCELL RBLT NUMBER SPACE | SPACE GREP SPACE BSC5 ......................................................................... ............... HOW TO REMOVE THE TG AND CELL?? RXMOE:MO=RXOtG-220&-221; RXMOE:MO=RXOtS-220-11-0&&-7; RXMOE:MO=RXOtS-220-10-0&&-7; RXMOE:MO=RXOtS-220-9-0&&-7; RXMOE:MO=RXOtS-220-8-0&&-7; RXMOE:MO=RXOtS-220-7-0&&-7; RXMOE:MO=RXOtS-220-6-0&&-7; RXMOE:MO=RXOtS-220-5-0&&-7; RXMOE:MO=RXOtS-220-4-0&&-7; RXMOE:MO=RXOtS-220-3-0&&-7; RXMOE:MO=RXOtS-220-2-0&&-7; RXMOE:MO=RXOtS-220-1-0&&-7; RXMOE:MO=RXOtS-220-0-0&&-7; RXMOE:MO=RXOTX-220-0&&-11; RXMOE:MO=RXORX-220-0&&-11; RXMOE:MO=RXOTRX-220-0&&-11; RXMOE:MO=RXOTF-220; RXMOE:MO=RXOIS-220; RXMOE:MO=RXOCON-220; RXMOE:MO=RXOCF-220; RXAPE:MO=RXOTG-220,DCP=ALL; RXTCE:MO=RXOTG-220,CELL=,CHGR=; RXMOE:MO=RXOTG-220

......................................................................... ...................... RXMOI:MO=RXOTG152,COMB=HYB,RSITE=PALMSTRPSHPCPLX,SWVER=B0531R0808,TRACO=POOL; RXMOC:MO=RXOTG-152,FHOP=BB; RXMOI:MO=RXOCF-152,TEI=62; RXMOI:MO=RXOIS-152; RXMOI:MO=RXOTF-152,TFMODE=SA; RXMOI:MO=RXOTRX-152-0,TEI=0,DCP1=128,DCP2=129&130; RXMOI:MO=RXOTRX-152-1,TEI=1,DCP1=131,DCP2=132&133; RXMOI:MO=RXOTRX-152-2,TEI=2,DCP1=134,DCP2=135&136; RXMOI:MO=RXOTRX-152-3,TEI=3,DCP1=137,DCP2=138&139; RXMOI:MO=RXOTRX-152-4,TEI=4,DCP1=140,DCP2=141&142; RXMOI:MO=RXOTRX-152-5,TEI=5,DCP1=143,DCP2=144&145; RXMOI:MO=RXOTX-152-0&&-5,BAND=GSM900,MPWR=33; RXMOI:MO=RXORX-152-0&&-5,BAND=GSM900,RXD=AB; RXMOI:MO=RXOTS-152-0-0&&-7; RXMOI:MO=RXOTS-152-1-0&&-7; RXMOI:MO=RXOTS-152-2-0&&-7; RXMOI:MO=RXOTS-152-3-0&&-7; RXMOI:MO=RXOTS-152-4-0&&-7; RXMOI:MO=RXOTS-152-5-0&&-7; RXAPI:MO=RXOTG-152,DCP=1&&18,DEV=RBLT-4865&&-4882; !RXTCI:MO=RXOTG-152,CELL=47432,CHGR=0; ......................................................................... ................................................ how to check the palm start test:ALLTI:ALI=0; END TEST ALLTE:ALI=0; ......................................................................... .......................

radep:dev=rtth1d-965; 1 ntcop:snt=rtth1s-30;

to check the dev under wiche snt to print the dev under this snt

rrtbi:dev=rtth1d-962&&-991,FORCE;

to block the dev

ntbli:snt=rtth1s-30; to block the snt

FIRST STEP-

SECOND STEP-2 THIRD STEP

-3

FORTH STEP-4

ntTEi:snt=rtth1s-30; to block the snt TO TEST SNT FIFTH-5 ntble:snt=rtth1s-30; to dblock the snt

SIX STEP-6

rrtbe:dev=rtth1d-962&&-991;to dblock the dev

SEVNTH STEP -7

......................................................................... ................... HOW TO GET THE PERSENTAGE% WHIL CHECKING THE SDCCH SUC WE WILL TAKE THE SUC ATTEMT% BY ALL ATEMTS THEN * 100= WE WILL GET THE PERSENTAGE. FOR EXAMPLE :

CELL SDCCH 41962

SDTCONG 0 CNRLCNG 0

SDDROP 0.3

ERLANG 2.1

CCALLS CMSESTB 1630 1044

CNDROP SDAVAIL 3 100

1044 /1630 * 100 =74% THIS WILL BE SDCCH SUC RATE. ......................................................................... .......................... HOW TO CHECK IF THE LINK USED OR NOT NTCOP:SNT=ETRBLT-6; STDEP:DEV=RBLT-6523&&-6985; IF WE GET CONFIG LINK USED.

NP THAT MEAN LINK NOT USED AND IF WE GET P THAT MEAN

......................................................................... ...............................

HOW TO TAKE BACKUP: 1-FORMAT THE OD. INMCT:SPG=0; INVOL:NODE=A,IO=OD-1,VOL=B34041131; END; 2-MOUNT THE OD. INMCT:SPG=0; INVOL:NODE=A,IO=OD-1; END;

3-TRANSFER THE FILE. INMCT:SPG=0; SYMTP:FILE1=RELFSW2,NODE=A,IO2=OD-1,DIR=OUT,SPG=0; ; ......................................................................... .................................. HOW TO CHECK NEIGHBOUR RELATION. RLNRP:CELL=24711,CELLR=ALL; ......................................................................... FOR UMTS SITE HOW TO ACTIVED AND HALTED

1-ACT CELL AFTER THAT PRESS ENTER THEN PUT CELL ID AND F9 TO EXCUTE THE COMMAND. 2-DEA TO HALT THE CELL. 3- F7 TO SEE LAST COMMAND YOU DID. ...................................................................... HOW TO CONNECT TO THE IOG WHILE BSC NOT CONECTING IN THE TOP WE WILL WRITE ((NE=BSC2,NODE=A)) APLOC: YOU WILL DEAL WITH THE BSC LIKE DOS PROGRAM HOSTNAM ...IT WILL TELL YOU IN WHICH NODE Y R WORKING

PRCSTATE...IT WILL TELL YOU WHICH NODE ACTIVE FCCRESTART OTHER...THIS COMMENT WILL RESTART OTHER NODE . LIKE IF NODE B NOT WORKING YOU CAN CONNECT TO NODE A AND RESTART NODE B. ......................................................................... ........................................................ HOW TO TEST ALARM IN ALV AND GENERAT ALARM test system; end test; ......................................................................... ............ IN CASE OF THE RBLT IS ETM....WE CAN NOT DEBLOCKED BY DTBLE WE CAN DO -TPCOP:SDIP=ALL;...WE CAN CHECK THIS RBLT UNDER WHICH ETM. SDIP 5ETM2

SNT ETM2-4

MS MS-0 MS-1

CLREF

HP VC4-0

LP VC12-0 VC12-1 VC12-2 VC12-3 VC12-4 VC12-5 VC12-6 VC12-7 VC12-8 VC12-9 VC12-10 VC12-11 VC12-12 VC12-13 VC12-14 VC12-15 VC12-16 VC12-17 VC12-18 VC12-19 VC12-20 VC12-21 VC12-22 VC12-23 VC12-24 VC12-25

K 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2

L 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 1 1 1 2 2

M 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2

DIP RBLT126 RBLT127 RBLT128 RBLT129 RBLT130 RBLT131 RBLT132 RBLT133 RBLT134 RBLT135 RBLT136 RBLT137 RBLT138 RBLT139 RBLT140 RBLT141 RBLT142 RBLT143 RBLT144 RBLT145 RBLT146 RBLT147 RBLT148 RBLT149 RBLT150 RBLT151

FOR EXAMPLE THE RBLT FROM 126 UNTEL151 ALL THIS UNDER SDIP 5ETM2. 2-TPBLE:SDIP=5ETM2,LP=(WE CAN WRIT ANY RBLT LP FOR EXAMPLE FOR RBLT126 THE LP WILL BE VC12-0; THE COMMAND WILL BE.

TPBLE:SDIP=5ETM2,LP=VC12-0;

......................................................................... ........................................................... RLSBP:CELL=ALL>>>>>>>>>> TO CHECK THE CELLS IS BARING OR NOT.. RLSBC:CELL=ALL,ALL,ACC=CLEAR,MAXRET=4>>>>>>>>TO CLEAR ALL BARING CELL. ......................................................................... ........................................... HOW TO NO THE TYPE OF CABNET BY RXOCF .....

IF YOU ARE GETTING SHALF 1 THAT MEAN 2101........IF YOU ARE GETING SHALF 7 THAT MEAN 2202.....IF YOU ARE GETTING-3229-TAHT MEAN 2301 IF YOU ARE GETTING 3696 OR 3678 THAT MEAN 2302....... ......................................................................... .......................................... RLSLC:CELL=31640,CHTYPE=TCH,LVA=27; TO CHANGE THE ALARM LEVEL. ......................................................... HOW TO RESET THE PORT WHEN THERE IS NO CONNECTION TO THE BSC IMLIT:SPG=0; ILNPP:PORT=ALL;.......TO CHECK ALL THE PORT ILBLI:NP=1-1-2-4; TO BLOCK THE PORT ILBLE:NP=1-1-2-4; TO DBLOCK THE PORT END; THE RATE WILL START WITH 64000; ......................................................................... .................

RLCFI:CELL=45023,DCHNO=979,CHGR=1;

HOW TO ADD ONE FREQ

RLCFE:CELL=45023,DCHNO=1011,CHGR=1; HOW TO REMOVE ONE FREQ

......................................................................... ........................................ C7LAE:LS=2-540,SLC=11;

TO BLOCK THE SLC IN C7LINK

......................................................................... ..................... HOW TO KNOW THE TYPE OF CDU RXMFP:MO=RXOCF-11; IF THE REVISION 135/1 THE CDU C+E......123/1 CDU C

THE CDU C+......113/1

THE

......................................................................... .............. HOW TO CHECK THE ALARM FROM PC IN CASE OF APG BSC DOWN.. 1-FIRST OPEN COMMAND PROMPT FROM ACCESSORIES 2-THEN TYPE TELNET AND CLUSTOR NUMBER OF BSC ( TELNET 10.50.2.18) 3- USER NAME:BSSOSS PASSWORD: INIT THEN BSC NUMBER LIKE (INIT23) 4- TYPE MML 5- THEN DO ALLIP OR ANY COMMAND YOU WANT ...................................................................... .................................... THE CLUSTER OF BSC 10.50.2.18 FOR BSC21 10.154.35.47 FOR BSC22 10.50.2.25 FOR BSC23 10.55.102.23 FOR BSC24 10.154.35.54 FOR BSC 25 10.153.14.17 FOR BSC37 ......................................................................... ............ WHEN BSC FULL WE WILL GET ALARM SAAEP:SAE=500,BLOCK=ALL;

EPORTED TO CHECK THE VALUE OF THE CP

SAAII:SAE=500,BLOCK=RXOLE,NI=10000; SAAII:SAE=500,BLOCK=RXO3EP,NI=10000; SAAII:SAE=500,BLOCK=RXO3OM,NI=10000; SAAII:SAE=500,BLOCK=RXOABH,NI=10000; SAAII:SAE=500,BLOCK=RXOFH,NI=10000; SAAII:SAE=500,BLOCK=RXOIFH,NI=10000; SAAII:SAE=500,BLOCK=RXOPL,NI=10000; SAAII:SAE=500,BLOCK=RXOADE,NI=10000; THIS COMMAND TO INCREAS THE VALUE OF THE CP; ......................................................................... .......................... HOW TO CHECK THE ACTIVE AND IDEL LIST RLMFP:CELL=24512: HOW TO ADD THE FREQ TO THE CELL RLMFC:CELL=40862,MBCCHNO=538,MRNIC; ................................................................... HOW TO RESET THE LINK IN CASE OF NETWORK SYNCHRONIZATION FAULT?? FIRST WE HAVE TO PRINT NSSTP; NSBLI:RCM=RCM-0; NSTEI:RCM=RCM-0; NSBLE:RCM=RCM-0; NSSTP; NSBLI:SDIP=2ETM1,MS=MS-0; NSTEI:RCM=RCM-0; NSBLE:SDIP=2ETM1,MS=MS-0; ......................................................................... ..... HOW TO CHECK THE SLC UNDER WHICH RALT(CCITT7 SIGNALLING LINK FAILURE) -REPORT TO TEMC C7LTP:LS=ALL; C7LDP:LS=ALL; IF THE SLC NUMBER 5 YOU WILL GET X05-5 IF 6 YOU WILL GET XO5-6 RADEP:DEV=RALT2-513 ; NTCOP:SNT=ETM2-0; EXSCP:NAME=ALL;

......................................................................... ...... ..................................................................... HOW TO CHECK THE STATE IF THE NODE A AND B IS WO OR SB?? IMMCT:SPG=0; IMCSP; END; ......................................................................... ...... TO CLEAR THE NODE RESTART ALARM IMMCT:SPG=0; IMRDP:NODE=A,FORM=SMALL; END; ......................................................................... .................... HOW TO DELET AND REDEFINE THE NSVCI THE GPRS... NSVCI=41501 ----------rrvbi:nsvci=41501; RRNSE:nsvci=41501;

!BLOCK NSVCI! !DELETE NSVCI!

RRNSI:NSVCI=41501,DLCI=130,DEV=RTGLT-1,NUMDEV=6; rrvbe:nsvci=41501; !DEBLOCK NSVCI!

!DEFINE NSVCI!

NSVCI=41502 ----------rrvbi:nsvci=41502; RRNSE:nsvci=41502;

!BLOCK NSVCI! !DELETE NSVCI!

RRNSI:NSVCI=41502,DLCI=131,DEV=RTGLT-33,NUMDEV=6; rrvbe:nsvci=41502; !DEBLOCK NSVCI!

!DEFINE NSVCI!

......................................................................... ................... GSSTP; TO PRINT ALL GROUP SWITCH STATE EXRPP:RP=ALL;

TO PRINT ALL RPS

CLM,SPM,TSM

BLRPI:RP=296,FORCED;

TO BLOCK THE RP

GSBLE:TSM=TSM-A-41;

TO DEBLOCK THE TSM

GSBLI:TSM=TSM-A-41;

TO BLOCK THE TSM

GSTEI:TSM=TSM-A-41;

TO TEST THE TSM

NTCOP:SNTP=TSM-13-1; TO CHECK THE TSM TO WHICH SNT CONNECTED NTBLI:SNT=ETRALT-40; TO BLOCK THE RALT BEFOR BLOOKING WE HAVE TO BLOCK THE DEV BY BLODI:DEV=1425&&542; ......................................................................... ................ HOW TO KNOW IF THE LINK NOT USED??? BY USING STDEP:DEV= RBLT-1953&&-1983; IF WE GET CONFIG STATE NP THAT MEAN LINK NOT USED. ......................................................................... ....... TO CLEAR THE COMMAND LOG BLOCKED FAULT IN APG BSC SYCLI; ......................................................... HOW TO GIVE APG RESTART? FIRST WE HAVE TO CHECK WHICH NODE ACTIVE.. 1-NE=BSC24,NODE=A 2-PRCSTATE TO CHECK ACTIVE NODE A OR B 3- PRCBOOT TO GIVE RESTART. ......................................................................... ........................ HOW TO CLEAR HEARTBEAT FAILURE

CLUSTER RES MCS-ADH-ADM /OFF LINE/ WAIT CLUSTER RES MCS-ADH-ADM /ON LINE/ WAIT ......................................................................... .............................. HOW TO CLEAR AP FAULT AND AP REPOT

-CHECK WHICH NODE - ALIST - ACEASE 6012:0 THIS NUMBER WILL BE ALARM IDENTIFIER ......................................................................... ............................. IN CASE IF NO CONNECTION TO THE APG BSC WE CAN LOG ON IN WINFIOL USERNAME:ADMINISTRATOR PASS:BSC(NUMBER)ADMIN ......................................................................... ........ HOW TO SWITCH FROM 1 ETM TO OTHER IN CASE OF SLC FAILURE PWNSP:SDIP=1ETM1; PWMSI:SDIP=1ETM1,MS=MS-1; ......................................................................... ...................................... TO ADD FREQ ON BA LIST RLMFP:CELL=31751; RLMFC:CELL=31753,MBCCHNO=77,MRNIC; ......................................................................... ................... IN CASE OF IO FAULT IOBLI:IO=AT-5; IOBLE:IO=AT-5; ......................................................................... ........................... DPWSP;......................................TO CHECK THE CP STATE SHOUD BE...IN CASE OF CP FAULT OR SYSTEM RESTART WE HAVE TO CHECK THIS COMMAND

MAU NRM

SB B

SBSTATE WO

......................................................................... ................. SYRIP:SURVEY;..........TO CHECK THE BSC RESTART TIME AND TYPE SMALL OR LARGE.

......................................................................... ......................... impact .........we are using this word in alex to cheak all new figiher ......................................................................... ...................................................... I ZONE SITE for the router the password will be (etpwlanpublic) for the access point the password will be (etpwlanprivate) ROUTER=R

ACCESS POINT=AP

......................................................................... ................................................... TO CHECK IF THE HARDWARE SUPORT GSM BAND OR NOT RXCAP:MO=RXOTX-87-0&&-1;

......................................................................... ............... RLBCP:CELL=25941;

TO PRINT POWER CONTROL

RLBCE:CELL=25941;

TO DACTIVE POWER CONTROL

RLBCI:CELL=25941:

TO

ACTIVE

POWER CONTROL

..................................................................... RAEPP:ID=ALL; TO PRINT BSC LEVEL PRAMETERS RAEPC:PROP=MCCSUPPORT-2; TO DO THE CHANGE .............................................. TO MAKE PROYERTY FOR OL SUB CELL.

RLLLP:CELL=3293; RLLLC:CELL=3293,SCLDLUL=100;

......................................................................... ..

RLSLC:CELL=32102,SCTYPE=OL; RLLLC:CELL=32102,SCLDSC=UL; RLSBP:CELL=Y51118; RLSBC:CELL=Y51118,CRO=5; RXBLI:MO=RXOTRX-365-7,SUBORD,FORCE; RXESE:MO=RXOTRX-365-7,SUBORD; RXMOE:MO=RXOTS-364-7-0&&-7; RXMSP:MO=RXOTRX-364-0&&-11;

RLCPP:CELL=Z51280; RLCPC:CELL=Z51280,BSPWRB=41, BSPWRT=41; SAAEP:SAE=1153; RLDEP:CELL=Z51270; RXTCP:MO=RXOTG-256; RXMOP:MO=RXOTX-341-0; DTSTP:DIP=RBLT364; SAAEP:SAE=1153; RXTCP:MO=RXOTG-341; RXMSP:MOTY=RXOTX; RXBLE:MO=RXOTRX-185-0&&-11; RXMSP:MO=RXOTRX-341-0&&-11; RXBLI:MO=RXOTRX-341-11,SUBORD,FORCE; RXESE:MO=RXOTRX-341-11,SUBORD; RXMOE:MO=RXOTS-341-11-0&&-7; RXMOI:MO=RXOTRX-365-4,TEI=4,DCP1=214,DCP2=215&&222,SIG=CONC; RXMOI:MO=RXOTRX-365-5,TEI=5,DCP1=223,DCP2=224&&231,SIG=CONC; RXMOI:MO=RXOTRX-365-6,TEI=6,DCP1=232,DCP2=233&&240,SIG=CONC; RXMOI:MO=RXOTRX-365-7,TEI=7,DCP1=241,DCP2=242&&249,SIG=CONC; RXMOI:MO=RXOTX-365-4&&-7,BAND=GSM900,MPWR=47; RXMOI:MO=RXORX-365-4&&-7,BAND=GSM900,RXD=AB; RXMOI:MO=RXOTS-365-7-0&&-7; RXESI:MO=RXOTG-365,SUBORD;

RXBLE:MO=RXOTG-365,SUBORD; RXMSP:MO=RXOTRX-365-1,SUBORD; RXBLE:MO=RXOTX-365-0; RLSTC:CELL=Z51270,STATE=ACTIVE; RLSLP:CELL=Z51270; RXCDP:MO=RXOTG-365; RXMFP:MO=RXOCF-365,SUBORD,FAULTY; RLCFP:CELL=Z51270; RXMSP:MO=RXOTRX-365-0&&-11; ******************* NETWORK SYCHRONIZATION FAULT************************* NSBLI:SDIP=4ETM2,MS=MS-0; NSTEI:SDIP=4ETM2,MS=MS-0; NSBLE:SDIP=4ETM2,MS=MS-0; ********************* GB LINK **************************** RRGBP; DTSTP:DIP=RTGLT0&RTGLT1; ******************** RP FAULT****************************** ALLIP; REPRI:RP=135; REMRI:RP=135,PCB=RPG2; ( OR REMRI:RP=986,PCB="GARP2-GPH B"; ) RECRI:RP=13; ************************************************************************* ********************************************************* HAMMADS COMMANDS ---------------cfind BSCN7 -date 2008-10 | grep 4999 more h_a_13oct_2008.txt ******HEART BEAT FAILURE*********** HOW TO KNOW IP ADDRESS OF BSC 1ST METHOD. IN GCELL WRITE eac_esi_config -ne BSCN6 IT WILL GIVE U PRINT OUT OF 3 IP ADDRESS FIRST IS IP, 2 & 3 IS SIDE A & B 2ND METHOD

OPEN OSSNETWORK EXPLORER IN RIGHT CLICK THEN ONRM_ROOTMO THEN SELCT BSCN6(ANY BSC) RIGHT CLICK MODIFY YES THEN NEXT NEXT TILL U GOT IP ADDRESS ***************************

12tru * 8 ts =96 , minus 3 for sdcch & 1 for bcch BSC PROCESSOR LOAD - IN CENTRAL DIRECTORY FILE NAME plldp.cfd.bak.bak ( run in ops) barring files (central directory barring- BSC6(FIRTS APPLY 20%) 1765 copier password CLEARING BARRING SERVER IP 10.48.155.34 checking stats http://10.66.105.50/Servint/hourly_stats.asp browser)

(checking stats in windows

IZONE http://10.99.91.152/CSCOnm/servlet/login/login.jsp(IZONE CHECKING dxb_hamad,Hammad22) SERVICEI INTRUPTION http://dxb00020124/serviceinterruption/ MNO FOLDER \\oasisj\MNO\VIP-FTR SMS SENDING https://smsb.etisalat.corp.ae:1117/Login.jsp? Myjsessionid=B9D35B52FA7D12A566E07C7B44E822EC.worker2 *********HOW TO CHECK IF LINK IS CASSCATED OR NOT??**** GCELL RBLT NUMBER SPACE | SPACE GREP SPACE BSC5 GCELL RBLT15 | grep BSC33GCELL RBLT15 | grep BSC33

****************** RALTS -- DIGITAL - FAULT SUPERVISION****

C7LDP:LS=ALL; (SHOWS LINK SET DATA) RADEP:DEV=RALT-1281; (SHOW DEVICE DATA IN BSC) ETRALT=40 REPORT LIKE THIS 3001+40 30041 IF ERROR ON LINK REPORT TO TRANIMISSION SYSTEM NO 3001 + 80 = 3081 BSC6 - X29 THIS FORMAT TO BE REPORTED. ****************************** WO = WORKING , ABL = AUTOMATIC BLOCK, MBL= MANUALLY BLOCK AIS= ALARM INDICATION SIGNAL (ALL 1'S) ACWL= AIRCRAFT WARNING ALARM CBI = CLEARED BYITSELF MCB = MAIN CIRCUIT BREAKER (ELCB) RDI = REMOTE DEVICE INDICATION RBO = RESET BY OMCR LOS = LOSS OF SIGNAL 1A 1A 1A 1A 1A 1A 1a 1A 1A 1A 1A 1A 1A 1A 1A 1A 1A 1A 1A 1A 1A 1A 1a 1A

1 1 2 4 5 5 7

ON CF POWER failure on trx "Reset, Power On" on cf & TRX "Reset, Switch" ON CF = DXU SOFTWARE FAULT ON TRX = "Reset, RAM Fault" ON CF = RAM FAULT ON CF on cf = bts in NOOP STATE 8 on cf Timing Unit VCO Fault 8 fault on trx Timing Reception Fault 9 FAULT on cf = TIME DISTRIBUTION FAULT 9 fault on trx = Signal Processing Fault 10 FAULT ON CF = INDOOR TEMP OUT OF RANGE 10 ON TRX = toora dona communication fault 11 ON TRX FAULT = DSP CPU COMMUNICATION FAULT 12 fault on cf DC Voltage Out Of Range 13 FAULT ON TRX = RX LOOP TEST FAULT 14 fault on cf Bus Fault 14 fault on trx RU DATABASE CORRUPTED 17 fault on cf HW And IDB Inconsistent 17 fault on trx = X-Interface Fault 18 ON TRX = DSP Fault 19 on trx "Reset, DXU Link Lost" 21 FAULT = ON CF HW FAULT 21 fault on trx Internal Configuration Failed

1A 22 ON TRX =Voltage Supply Fau 1A 23 on trx Air Time Counter Lost

1A 25 ON TRX FD=TX/RX Communication Fault 1A 30 ON TRX FD=DSP RAM Soft Error 1B 1 ON RXOTF DXU-Opt EEPROM Checksum Fault 1B 1 ON TRX INDOOR TEMP OUT OF SAFE RANGE 1B 0 FAULT = CDU NOT USABLE (ON TX) 1B 0 ON TRX = CDU COMBINER NOT USABLE 1B 2 fault on tx CDU Output Power Limits Exceeded 1B 3 fault on trx DC Voltage Out Of Range 1B 4 fault ON TRX LOCAL MODE /Indoor Temp Above Safe Range 1B 4 fault on tx TX Antenna VSWR Limits Exceeded EXTERNAL1B 4 ON CF FD=L/R SWI '('BTS In Local Mode')' EXTERNAL1B ON CF 4 FD=L/R SWI '('TRU In Local Mode')' 1B 1B 1B 1B 1B 1B 1B 1B

5 external on cf L/R TI (Local to Remote while Link Lost) 5 ON RXORX RX Synthesizer A/B Unlocked 7 fault on RX Communication Fault 13 FAULT = TX Output Power Limits Exceeded 8 FAULT = TX SYNTHESIZER A/B UNBLOCKED 9 ON TRX FD=Y Link Communication Lost 9 ON RX = RX CABLE DISCONNECTED 27 ON TX = TX MAX POWER RESTRICTED

1B 10 fault on tx TX Communication Fault 1B 10 fault on RX RX Initiation Fault 1B 10 ON TRX TIMING RECEPTION FAULT 1B 14 ON TX= TX Saturation 2B 10 FAULT = REPORTED TO POWER 2B 9 FAULT = DOOR ALARM external 2b 4 CXU TRU RXB CABLE fcode external 1B 4

2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2a 2A 2A 2A 2A

0 ON TRX=RX CABLE DISCONNETED 1 FAULT ON CF = RESET POWER ON 1& 2 ON TRX FAULT = RX Path Loss 3 on trx RX Synthesizer Unlocked 4 ON TRX RX Internal Voltage Fault 5 ON TRX RX Communication Fault 6 on cf "Reset, Internal Function Change" 6 TX COMMUNICATION FAULT 8 FAULT = ON CF/VSWR Limits Exceeded 9 on cf Power Limits Exceeded 12 on cf TX Output Power Limits Exceeded 12 ON TRX TX Output Power Limits Exceeded 13 ON TRX TX Saturation 14 on cf Supervision/Communication Lost 14 ON TRX Voltage Supply Fault 15 VSWR/Output Power Supervision Lost 16 faukt ON CF = indoor temp out of SAFE RANGE 16 ON TRX = NON VOLITILE MEMORY CORRUPTED 16 on cf Indoor Temp Out Of Normal Conditional Range 17 on trx Loadfile Missing in TRU 18 ON CF DC Voltage Out Of Range

2A 19 on cf Power and Climate System in Standalone Mode 2A 12 FAULT = RX Maxgain/Mingain Violated 2A 2A 2a 2A 2A 2A 2A 2A 2A 2A

23 FAULT = ON CF CLIMATE CAPICITY REDUCED 23 ON TRX Default Values Used 22 fault on trx voltage supply fault 22 fault on cf Battery Backup Capacity Reduced 21 FAULT = INTERNAL POWER CAPACITY REDUCED 25 FAULT ON TRX, TX Max Power Restricted 26 FAULT ON CF Climate Sensor Fault 26 Fault ON RXOTRX DB parameter fault 25 fault on cf Loadfile Missing in DXU or ECU 28 fault on cf A/D Converter Fault

2A 2A 2A 2A 2A

29 30 31 32 33

FAULT fault FAULT fault FAULT

2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A 2A

36 37 38 39 39 46 41 40 40 42 43 45 46 53 54

fault= on cf RU Data Base Corrupted fault on cf Circuit Breaker Tripped or Fuse Blown fault on cf Default Values Used FAULT = on trx RF Loop Test Fault, Degraded RX" FAULT ON CF RX CABLE DISCONNECTED FAULT = ON CF/DB PARAMETER FAULT / INSTALL IDB FAULT = ON CF/LOST COMM TO TRU FAULT = DXU LINK LOST FAULT ON TRX MEMORY FAULT. fault on cf Lost communication to ECU on cf Internal Configuration Failed ON CF HIGH TEMP on cf DB parameter fault ON CF H/W & IDB INCONSISTENT ON CF TIMING BUS FAULT

on cf = VARISTOR FAULT (CABINET) = on CF Bus Fault ON CF High Frequency Software Fault oncf Non-Volatile Memory Corrupted = RX DIVERSITY LOST

DFNF PROBLEM (DISK FILE NOT FOUND) OPERATIONAL SOFTWARE NOT PRESENT IN APG OR IOG OR NOT PROPERLY INSTALLED IDB TO BE INSTALLED AGAIN ************ CHEKING GPRS******** RRGRP; GSSTP; RLGSP:CELL=44711; RLGRP:CELL=44711; RLBDP:CELL=44711; RLPDP:CELL=44711; raepp:id=all; raepc:prop=CHCODING-1;

rlgsc:cell=44711,FPDCH=8; rlcfp:cell=44711; rlstc:cell=44711,state=ACTIVE; RLCRP:CELL=44711; RRGBP; CHECKING GRPS LINKS . RLGSP:CELL=13611; IF FPDCH=1 THEN GRPS IS THERE IF =0 THEN NO GPRS RLGRP:CELL=13591; RLGSC:CELL=21332,FPDCH=1; ( TO CHANGE FPDCH VALES BUT BEFORE MAKE GPRS OFF) RLGSE:CELL=13611; RLGSI:CELL=13611;

BLOCK DEBLOCK

GPRS ANY SITE NOT CARRYING TARFFICE & RP RESET. RLGRP:CELL=41591; TAKE RP AND RESET *******************DYNAMIC BTS POWER CONTROL CELL DATA***************** RLACP:CELL=40092; (STATE ON OR OFF SDCCH MORE OR LESS ACCORDING TO TRAFIC) RLBCP:CELL=14161; (Radio Control Cell, Dynamic BTS Power Control, End) RLBCE:CELL=14161; (INACTIVE OR OFF) RLBCP:CELL=14161; (ACTIVE OR ON) RLBCI:CELL= rlssp:cell=32021; ( to check nccperm ) RLDGP:CELL=31021;(GROUP) RLDEP:CELL=31021;(DESCRIPTION DATA) RLLHP:CELL=31021;(LAYERS) RLLHC:cell=4562,layerthrshod=45; this coomand to change all this parametars RLCFP:CELL=31021; FREQUENCIES (CONFIGRATION FREQUENCY DATA) RLCFI:CELL=31021,DCHNO=17; (TO ADD FREQUENCY) RLCFE:CELL=31021,SDCCH=2OR 3 OR 4 ,CHGR=0,1; (TO DELETE FREQUENCY) RLCPP:CELL=31021; (POWER DATA) RLCPC:CELL=, BSPWRT=12, BSPWRT= & BSPWRB .....TO CHANGE THE PRAMETER RLSSP:CELL= 21312; TO PRINT ACCMIN CCHPWR,CRH,DTXU,RLINKT,NECI,MBCR,NCCPERM RLSSC:CELL=

TO CHANGE THIS PARAMETER

RLNRP:CELL=24711,CELLR=ALL ( ALL BEIGHBOURING RELATIONS)

RRGBP;

(TO CHECK ALL GB LINK)

RLGRP:CELL=ALL; BACKB RLMFP:CELL=26261;

( TELLS IN CELLS GPRS POSITION) (TELLS BCCHNO OF NEIGHBOUR)

***************** HOW TO DEFINE NEIGHBOURING REALTIONS******* RLNRP:CELL=24711,CELLR=ALL RLNRE:CELL=31721,CELLR=3622; RLNRI:CELL=31721,CELLR=3622;

! DELETING ! DEFINING

*************** NETWORK SYSNCHORONIZATION FAULT ****************** NSBLI:SDIP=2ETM1,MS=MS-0; NSTEI:SDIP=2ETM1,MS=MS-0; NSBLE:SDIP=2ETM1,MS=MS-0; NSSTP; NSBLI:DIP=RALT64; NSTEI:DIP=RALT16; NSBLE:DIP=RALT16; ********** GPRS/EGPRS ****************** RBS2101,2308,2302 NOT SUPPORT EGPRS ONLY SUPPORT GPRS 2 ONLY

CODING SCHEME 1 &

RBS2202 SUPORT GRPS&EGPRS FOR EGPRS IT REQUIRE STRU RBS2206 SUPORT GRPS&EGPRS FOR EGPRS IT REQUIR EDTRU BOTH 2202 & 2206 REQUIR CODING SCHEME 0 TO 4 *********************** TO CHANGE LVA VALUE IN RLSLP **************** eaw BSC15 ( WE CAN CHECK ALL STATUS IN GCELL SCRIPT INSTEAD OF COMMAND HANDLER) RLSLP:CELL=4722; RLSLC:CELL=4722,CHTYPE=TCH,LVA=83; ( 82 OR 83 ANY VALUES TO BE CHANGED)

***************** TO CHECK THE LOOP **************************** RXLTI:MO=RXOTS-28-10-0&&-11;

********** FOR LOOP RELEASE ********************************** RXMOP:MO=RXOTG-226; (CHECK THE TGFID NUMBER DOWN) SYFRI:FID=H'0000-H'996F,BLOCK=RXOTG,IND=226,FILENUM=1; (FOR LOOP RELEASE) (A command is used for ordering a manual Forlopp release. As parameters the Forlopp ID and the reference to a connected individual must be given. If a number of Forlopp releases are pending, the manual initiated Forlopp release will be the first to be executed. If too many Forlopp releases are pending the command will be rejected. ) RXPLI:MO=RXOTG-226,UC; (FORCE LOADING THE SOFTWARE) ***************HOW TO KNOW BTS TYPE WITHOUT GCELL *************** RLLHP:CELL=42421; IF LAYER =2 MICRO IF LAYER = 3 MACRO BOE 602 14/1 2206 CABINET RXMFP:MO=RXOCF-336; IF DXU ON SHELF 7 = RBS 2202 (CHECK ON DXU) SHELF 8 & 6 = RBS 2206 SHELF 1 = RBS 2101 SH:--& REVISION 3678 === 2302 SHU:-- & REV 32XX & ROA 32XX === 2301 SHU:3 === 2106 e.g IXU >>>>>>>>>> 2308 1--

RUPOSITION C:0 R:C SH: 8 SL: 48

2-- RU RUREVISION 0 ROA 117 3678/1 NOT EDGE

RULOGICAL DX DX DXU_21 R3A

RUSERIALNO A532320165

DXU_21 ==== 2ID ==== 2206 ===== 2301/2302

RLBDP:CELL=42591; (IF EDGE ENABLED THEN ENTRIES SHOULD BE THERE) 1- ROA 117 3229/1 2- ROA 117 3229/2

==== NOT EDGE 1002/2

==== EDGE

DCP1 IF DCP VALUES ARE 2 THEN EDGE DEFINED HOW TO DEFINE EDGE DCP1

232

TEI=0 DCP1=178,DCP=179&&186

rlstc:cell=4692,state=halted; rxbli:mo=rxotg-133,force,subord; rxese:mo=rxotg-133,subord; RXMOE:MO=RXOTRX-133-0; RXMOI:MO=RXOTRX-133-0,TEI=0,DCP1=178,DCP2=179&&186; RXMOC:MO=RXOTRX-133-0,CELL=4692,CHGR=2; RXMOC:MO=RXOTX-133-0,CELL=4692,CHGR=2; rxmoc:mo=rxotrx-133-0,sig=conc; RXAPP:MO=RXOTG-133; RXAPI:MO=RXOTG-133,DEV=RBLT2-4285&&-4287,DCP=29&&31,RES64K; RXMsP:MO=RXOTG-133,SUBORD; rlstc:cell=4692,state=active; rlslp:cell=4693; rlgrp:cell=4693; rlgsi:cell=4692; ***************HOW TO KNOW RBLT WITHOUT GCELL *************** RXTCP:MO=RXOTG,CELL=4671; RXTCP:MOTY=RXOTG,CELL=4671; RXAPP:MO=RXOTG-1; ************* TO SEE THE TG ****************** RXTCP:MOTY=RXOTG,CELL=41653; *******************MASTER & SLAVE ************** RXMOP:MO=RXOCF-203; (IF TEI=61, THEN SLAVE IF TEI=62=MASTER) ALL BELOW 62 ARE SLAVE ************************ BLOCKING AND DE BLOCKING ************ (RADIO X-CEIVER ADMINISTRATION MANUAL BLOCKING OF MANAGED OBJECT, END) BLOCK INITIATED RXBLI:MO=RXOTRX-120-0&&-3!,FORCE; BLOCK END RXBLE:MO=RXOTRX-120-0&&-3!, THEN CHECK TO SEE STATUS

(&& MEANS 3 TRU'S BLOCK)

TO CHECK ON BOARD WHICH TG IS FAULTY***********

RXMFP:=MO=RXOTG-30, SUBORD,FAULTY; RXOTX & RXOCF

(MANAGED OBJECT FAULT INFORMATION)

RXMSP:MO=RXOTX-137-0&&-11; RXELP:MO=RXOTX-137-0&&-11;

( SHOWS BLOCK/OPERATIONAL ) (SHOWS FAULT HISTORY)

*****************TO CHECK STATUS OF BLOCK/WORKING (ETC CARD) ***************** TO CHECK THE LINK CONNETED IN THE ETC CARD IN THE BSC'S NTSTP:SNT=ETRBLT-34;

(SWITCHING NETWORK TERMINAL STATE, PRINT)

RESULT WILL BE >>>>> WHEN ONLY SNT DOWN >>>SWITCHING NETWORK TERMINAL FAULT NTBLI:SNT=RHSNT-1; NTTEI:SNT=RHSNT-1; NTBLE:SNT=RHSNT-1; NSSTP; (FOR CHECKING) C7LTP:LS=ALL; ( CHECKING) 1- NTSTP:SNT=ETRBLT-3;

(CHECK ABL OR WO) IF ABL THEN

2- NTBLI:snt=etrblt-3; 3- NTTEI:snt=etrblt-3; 4- NTBLE:snt=etrblt-3; *************** CHECK WITHOUT G-CELL RBLT OF ONE CELL*********** RXTCP:MOTY=RXOTG,CELL=26591;

(CHECK FIRST TG)

RXAPP:MO=RXOTG-37; FOR TG (GET DEVICE POSITION)Radio X-ceiver Administration Abis Path Status, Print. RXMDP:MO=RXOTRX-219-0

RADEP:DEV=RBLT-1185; (PUT DEVICE HERE ) DEVICE DATA PRINT RXMDP:MO=RXOTRX-337-0; RADEP:DEV=RBLT2-10800; NTCOP:SNT=ETM2-9; RADEP:DETY=ALL;

(IF IT COMMES STM2 )

(SHOWS ALL DEVICES IN BSC)

*************** TO CHECK RBLT IS CONNECTED OR NOT WITHOUT G CELL ********** NTCOP:SNT=ETRBLT-100; STDEP:DEV=RBLT-3201&&-3231; CONNECTED)

( ALL DEVICES SHOULD BE NP I.E NOT

********************* CHECK RXOTG GROUP WITHOUT GCELL ************** RXTCP:MO=RXOTG-92; PRINT)

(RADIO X-CEIVER ADMINISTRATION TG TO CHANNEL GROUP,

RXTCP:MOTY=RXOTG,CELL=47281; RESULT WILL BE
View more...

Comments

Copyright ©2017 KUPDF Inc.
SUPPORT KUPDF