Servo gauge 854 ATG
A compact, intelligent and reliable Advanced Tank Tank Gauge As tank tank gaugin gauging g has has evolve evolved, d, the the series series 854A 854ATG TG servo servo leve levell gauge gauge has become an industrial standard all over the world. Very reliable, versatile and accurate automatic tank gauge with a minimum of moving parts, meeting all international standards, regulations and recommendations. recomme ndations. A true test of its quality is the dependability and low warranty record that the ATG A TG has has mainta maintained ined for many year years. s. The multi multi-func -functiona tionall instrume instrument nt is mod modularly ularly cons construct tructed. ed. The option slots for additional features allow connecting to a wide range of other instruments e.g. temperature-, temperatur e-, pressure-, interface measurement and more. Obviously the connectivity to various eld busses and tank inventory or host systems can easily be accomplished. Simple conguration and diagnostics are possible through through a hand held device or via conguration software. software.
Technical specications Measuring specifications Measuring range : Standard Optional
Measuring accuracy level Measuring accuracy interface Measuring accuracy density Measuring accuracy temp. Sensitivity Repeatability Wave integration time Mechanical Flange Dimensions Weight
Cable entries Environmental Operating pressure
Ambient temperature Protection class Safety
Materials Housing servo comp. & cover Drum compartment
Finish aluminum parts Measuring drum, drum shaft Measuring wire Magnet cap O-rings Electrical Power supply
Frequency variations Power rating Transmission Type Isolating voltage Lightning protection Protocol Common mode rejection Cabling Transmission to Portable Enraf Terminal (PET) Options Alarm relay outputs Density measurement Analog level output Input boards
Data transmission Cable entries
: : : : : : :
27 m (88 ft) 37 m (121 ft) 35 m (115 ft) (with measuring wire up to 150 m (492 ft)) < ± 0.4 mm (± 0.016 ”) 1) < ± 2 mm (± 0.08 ”) 2) < ± 3 kg/m3 (± 0.19 lb/ft3 ) 3) ± 0.1 °C (± 0.18 °F) 1) 4) ± 0.1 mm (± 0.004 ”) 1) ± 0.1 mm (± 0.004 ”) 1) Programmable, three setpoints, between 0.5 s and 10 s
: See ‘Identication code’, Pos 9, 10 : See back page : Medium pressure version 16 kg (35 lb) Chemical version 21 kg (46 lb) High pressure version 26 kg (57 lb) : 4 pcs ¾” NPT threaded : M and C version : up to 6 bar / 0.6 MPa (90 psi) H version : up to 40 bar / 4 MPa (600 psi) (up to 25 bar / 2.5 MPa in acc. to PED) : -40 °C to +65 °C (-40 °F to +149 °F) : IP 65 according to EN 60529 (NEMA 4) : Explosion proof - II 1/2 G EEx d IIB T6 or EEx de IIB T6 or EEx d [ia/ib] IIB T6 or EEx de [ia/ib] IIB T6 according to ATEX - Class I, Division 1, Groups B, C and D, in acc. to ANSI / NFPA 70 (FM, USA) : All types cast aluminum Int. reg. AA A356 EN1706 AC-AlSi7Mg0.3 : M version cast aluminum Int. reg. AA A356 EN1706 AC-AlSi7Mg0.3 C & H version stainless steel ASTM A351, CF-8M, G-X6 CrNiMo 18 10 (1.4408) : Chromatized according to MIL-C-5541C : Stainless steel (1.4401) EN10088 ≅ AISI 316 : See ’Identication code’, Pos 12 : Stainless steel (1.3953) : Drum cover Silicone / FEP (others NBR 70) : 110/130/220 V (+10% to -20%) and 230 V (±15%), optional 65 V (+10% to -20%), also suitable for 240 V (+10% to -20%) : 50 Hz to 60 Hz (±10%) : 25 VA, Imax = 2 A : : : : : :
Serial, ASCII coded, Bi-Phase Mark modulated (BPM) > 1,500 V Full galvanic separation via isolating transformers Standard Enraf eldbus (GPU protocol) > 150 dB Two conductors, twisted pair, Rmax= 200 Ω / line, Cmax = 1 µF
: Infra-red, serial : : : :
2x SPDT, galvanically isolated, Vmax = 50 Vac or 75 Vdc, I max = 3 A See ’Identication code’, Pos 15 (with density displacer) 4 - 20 mA (accuracy ± 0.1% full scale) Spot RTD, VITO probes for average temperature and/or water measurement, HART® devices : Standard Modbus via RS-232C, RS-485 or Foundation Fieldbus® i.s. output for Tank Side Indicator (TSI) : Adapters available to t other sizes cable glands
HART® is a trademark of the HART Communications Foundation. Foundation Fieldbus® is a trademark of the Fieldbus Foundation. 1) Under reference conditions 2) Difference product density 100 kg/m3 (6.25 lb/ft3 ) 3) (optional) with a density displacer and calibrated for density measurement 4) With VITO temperature probe
Identication code Pos 1 Application U General purpose X W&M certied Pos 2 Data transmission E Enraf Biphase mark protocol (standard) I i.s. Output for Tank Side Indicator (TSI) and Enraf BiPhase Mark (BPM) protocol R RS232C GPU protocol (only when Pos 4 = B, C, J, U or Z) S RS485 GPU protocol (only when Pos 4 = B, C, J, U or Z) V RS232C standard Modbus (only when Pos 4 = B, C, J, U or Z) W RS485 standard Modbus (only when Pos 4 = B, C, J, U or Z) O Foundation Fieldbus + BPM Pos 3 Display A With display Pos 4 I/O options B Spot temperature Pt100 Analog level output + VITO temperature and/or W water probe C VITO temperature and/or water probe J VITO temp. and/or water probe + HART device(s) X Analog level output + VITO temperature probe U Spot temperature Pt100 + HART device(s) Analog level output + spot temperature Pt 100 + Y VITO temp. and/or water probe + HART device(s) V Analog level output Z None Pos 5, 6, 7 Instrument designation 8 5 4 Servo gauge ATG Pos 8 Pressure version C Up to 6 bar 0.6 MPa (90 psi) if Pos 9, 10 = 11, 12 or 13 M Up to 6 bar 0.6 MPa (90 psi) if Pos 9, 10 = 21 or 22 H Up to 40 bar 4 MPa (600 psi) if Pos 9, 10 = 51, 52, 53 or 54 (25 bar according PED) Pos 9, 10 Drum compartment & ange 1
1
1
2
1 2
3 1
2
2
5 5
1 2
5
3
5
4
mat. *) ange
acc. to
nish
compatible with
acc. to
ss
2” 150 lbs rf
ANSI B16.5
turning, Ra = 3.2 12.5 μm
DN50, PN20 rf
ISO 70051
ss
NW50 ND6 form D
DIN 2501 DIN 2526
turning, Rz = max. 40 μm
DN50, PN6 rf
ISO 70051
ss
2” 150 lbs ff
ANSI B16.5
turning, Ra = 3.2 12.5 μm
DN50, PN20 ff
ISO 70051
Al
2” 150 lbs ff
ANSI B16.5
turning, Ra = 3.2 12.5 μm
DN50, PN20 ff
ISO 70051
Al
NW50 ND6 form B
DIN 2501 DIN 2526
turning, Rz = 40 160 μm
DN50, PN6 ff
ISO 70051
ss
2” 300 lbs rf
ANSI B16.5
turning, Ra = 3.2 12.5 μm
DN50, PN50 rf
ISO 70051
ss
2” 300 lbs rf
ANSI B16.5
turning, Ra = 3.2 6.3 μm
DN50, PN50 rf
ISO 70051
ss
NW50 ND40 form C
DIN 2501 DIN 2526
turning, Rz = 40 160 μm
DN50, PN40 rf
ISO 70051
ss
NW50 ND40 form E
DIN 2501 DIN 2526
turning, Rz = max. 16 μm
DN50, PN40 rf ISO 70051 *) see also technical specications
Pos 11 Safety approvals A ATEX Europe For other approvals please contact your C CSA Canada nearest Enraf ofce F FM USA Pos 12 Measuring range & wire material 2 27 m (88 ft) AISI 316 K 37 m (121 ft) Hasteloy C22 A 27 m (88 ft) Hasteloy C22 L 37 m (121 ft) Tantalum B 27 m (88 ft) Tantalum M 37 m (121 ft) Invar C 27 m (88 ft) Invar N 37 m (121 ft) Platinum / 20% Iridium D 27 m (88 ft) Platinum / 20% Iridium 35 m (115 ft) AISI 316 9 with 150 m (492 ft) wire length 3 37 m (121 ft) AISI 316 Pos 13 Purge connection * Option not used L 1/4” BSP entry Pos 14 Mains supply A 220 V R 130 V 50/60 Hz 50/60 Hz C 110 V S 65 V 50/60 Hz 50/60 Hz K 230 V 50/60 Hz Pos 15 Density measurement D With servo density measurement * Option not used Pos 16 Alarms W With 2 programmable SPDT alarms Z No alarms U E A Z A
8
5
4 M 2
8
5
4
1
A
2
*
A
*
Z
Typical identication code Your identication code
Dimensional drawing 2 cable entries 3/4" NPT for non i.s. wiring. 436 mm (17 82 mm (3 1/4")
2 cable entries 3/4" NPT for i.s. wiring.
3/16" )
352 mm (13 7/8" )
233 mm (9 3/16")
infra-red coupling
Hoisting eye
" B "
" A "
100 mm (4") free space for IR connection
200 mm (7 7/8" ) (space needed to remove cover) Position of measuring wire with displacer in top position.
44 mm (1 3/4" )
"A"
M and C version H version
Ref. to the instr. code Pos. 9, 10 for the flanges available.
184 mm (7 206 mm (8
"B" 1/4") 1/8")
427 mm (16 13/16") 449 mm (17 11/16")
854 ATG
Cable specications Serial transmission Number of wires : 1 twisted pair (pref. shielded) Resistance : R max = 200 Ω / line Capacitance : C max = 1 µF Outputs • Modbus • 4-20 mA for level • Two relay level alarms • i.s. Output for Tank Side Indictor • Digital transmission to - indicators - systems Inputs • HART® devices • Spot temperature element • VITO probes for average temp. and/or water bottom measurement
Field interface
Honeywell Enraf Delftechpark 39 2628 XJ Delft The Netherlands Tel: +31 (0)15-2701 100 E-mail:
[email protected] www.honeywellenraf.com
PS-4417876-Rev.8-ENG March 2008 © 2008 Honeywell International Inc.
Entis system