Enhanced Measuement Reporting Activation
Short Description
This document tell us mainly about measurement processing of gsm Nokia activation foe better planning of second generati...
Description
Nokia Siemens Networks GSM/EDGE BSS, rel. RG10(BSS), operating documentation, issue 03
Activate
Activating and Testing BSS11086: Support for Enhanced Measurement Report DN70263009 Issue 1-0
Activating and Testing BSS11086: Support f or Enhanced Measurement Report
The information in this document i s subject to change without notice and descri bes only the product defined in the introduction of this documentation. This documentation is in tended for the use of Nokia Siemens Networks c ustomers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by pr ofessional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the pr ocess of continuous development and improvement of the documentation. The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or so ftware products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However , Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of m aterial errors and omissions. N okia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues whi ch may not be covered by the document. Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING B UT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUM ENT OR THE INFORMATION IN IT. This documentation and the product it desc ribes are considered protected by copyrights and other intellectual property rights according to the applicable laws. The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG. Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only. Copyright © Nokia Siemens Networks 2009. All rights reserved
f
Important Notice on Product Safety Elevated voltages are inevitably present at specific points in this electrical equipment. Some of the parts may also have elevated operating temperatures. Non-observance of these conditions and the saf ety instructions can result in personal injury or in property damage. Therefore, only trained and qualified personnel may install and maintain the system . The system complies with the standard EN 6 0950 / IEC 60950. All equipment connected has to comply with the applicable safety standards.
The same text in German: Wichtiger Hinweis zur Produktsicherheit In elektrischen Anlagen stehen zwangsläufig bestimm te Teile der Geräte unter Spannung. Einige Teile können auch eine hohe Betri ebstemperatur aufweisen. Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Körperverletzungen und Sachschäden führen. Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die Anlagen installiert und wartet. Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene Geräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.
2
Id:0900d8058059c09e
DN70263009 Issue 1-0
Activating and Testing BSS11086: Support for Enhanced Measurement Report
Table of Contents This document has 8 pages.
DN70263009 Issue 1-0
1
Activating and testing Support for Enhanced Measurement Report . . . . 5
2
Deactivating Support for Enhanced Measurement Report . . . . . . . . . . . 7
Id:0900d8058059c09e
3
Activating and Testing BSS11086: Support f or Enhanced Measurement Report
4
Id:0900d8058059c09e
DN70263009 Issue 1-0
Activating and Testing BSS11086: Support for Enhanced Measurement Report
Activating and testing Support for Enhanced Measurement Report
1 Activating and testing Support for Enhanced Measurement Report Before you start
Support for Enhanced Measurement Report is an application software product. It can be handled with the FIFILE parameter EMR_SUPPORT_IN_BSC , which is by default always set to OFF. You can activate Support for Enhanced Measurement Report at any time. Make sure that the following network elements and mobile stations are available: •
1 MSC
•
1 BSC with S11 software or later
•
1 GSM cell
•
Release '99 MS (or newer) supporting the EMR
•
NetAct supporting the EMR
g Enhanced Measurement Report can be used for reporting if the MS supports EMR and the idle state BCCH allocation list is not used for the serving cell. However, if you have activated Dynamic Frequency and Channel Allocation ( DFCA) in your network, EMR can be used for reporting together with the idle state BA list. For a description of Support for Enhanced Measurement Report, see Support for Enhanced Measurement Report. For deactivation instructions, see Deactivating Support for Enhanced Measurement Report. Steps
Check that you have the required version of the BCF software (EWO). ZEWO:;
Set the EMR_SUPPORT_IN_BSC parameter to ON (WOA). ZWOA:2,776,A;
Check the activation of the EMR_SUPPORT_IN_BSC parameter (WOS). ZWOS:2,776;
When the parameter state is changed, it takes about 16 minutes before the new state is active.
Modify the value of the cell bar qualify (QUA) parameter (EQM). ZEQM:BTS=::QUA=N;
or ZEQM:BTS=::QUA=Y;
After the EMR_SUPPORT_IN_BSC parameter is activated, the new system information messages have to be sent to all the sites. This can be done, for example, by modifying
DN70263009 Issue 1-0
Id:0900d8058059c098
5
Activating and testing Support for Enhanced Measurement Report
Activating and Testing BSS11086: Support f or Enhanced Measurement Report
the value of the cell bar quality (QUA) parameter from N to N (or from Y to Y) in all the cells of the BSC.
Set the FER_USAGE parameter to ON (WOA). ZWOA:2,628,A;
Set the RXQ_HAC_USAGE_P parameter to ON (WOC). ZWOC:10,28,FF;
Modify FER Measurement (TPM). ZTPM:MEASUR,FER:,,;
Start the measurement (TPS). ZTPS:MEASUR,FER:,;
Wait until the measurement is enabled.
Interrogate FER Measurement (TPI). ZTPI:MEASUR,FER;
Establish a call.
The real downlink FER counters of FER Measurement are updated immediately when mobiles use EMR for reporting.
Disconnect the call.
Check the measurement data.
At the end of the measurement period, check the measurement data in Nokia NetAct or in BSC using the MEFICO tool. Check that the real downlink FER counters of FER Measurement are updated. For more information, see: •
•
Reporter and Performance Management Principles in NetAct documentation
Converting BSC Measurement and Observation Files with MEFICO in BSC/TCSM documentation
Stop the measurement (TPE). ZTPE:MEASUR,FER;
6
Id:0900d8058059c098
DN70263009 Issue 1-0
Activating and Testing BSS11086: Support for Enhanced Measurement Report
Deactivating Support for Enhanced Measurement Report
2 Deactivating Support for Enhanced Measurement Report Before you start
For a description of Support for Enhanced Measurement Report, see Support for Enhanced Measurement Report. For activation instructions, see Activating and testing Support for Enhanced Measure ment Report. Steps
Check that the FER Measurement is in the UNLOCKED/ENABLED state (TPI). ZTPI:MEASUR,FER;
Set the EMR_SUPPORT_IN_BSC parameter to OFF (WOA). ZWOA:2,776,D;
Check the deactivation of the EMR_SUPPORT_IN_BSC parameter (WOS). ZWOS:2,776;
The deactivation takes effect during the next 16 minutes.
Modify the value of the cell bar qualify (QUA) parameter (EQM). ZEQM:BTS=::QUA=N;
or ZEQM:BTS=::QUA=Y;
After the EMR_SUPPORT_IN_BSC parameter is deactivated, the new system information messages have to be sent to all the sites. This can be done, for example, by modifying the value of the cell bar quality (QUA) parameter from N to N (or from Y to Y) in all the cells of the BSC.
Establish a call. Expected outcome
The real downlink FER counters of FER Measurement are not updated.
Disconnect the call.
Check the measurement data.
At the end of the measurement period, check the measurement data in Nokia NetAct or in BSC using the MEFICO tool. Check that the real downlink FER coun ters of FER Measurement are updated. For more information, see: •
DN70263009 Issue 1-0
Reporter and Performance Management Principles in NetAct documentation
Id:0900d8058059c09b
7
Deactivating Support for Enhanced Measurement Report
•
Activating and Testing BSS11086: Support f or Enhanced Measurement Report
Converting BSC Measurement and Observation Files with MEFICO in BSC/TCSM documentation
Stop the measurement (TPE). ZTPE:MEASUR,FER;
8
Id:0900d8058059c09b
DN70263009 Issue 1-0
View more...
Comments