Table Of Contents General Verification

2

Delivery of material

2

Suggested installation schedule

3

Installation procedure

4-12

Maintenance requirements

13-14

Valve adjustment

15-20

Operation instruction

21

Trouble shooting procedure

21

Safety Test Procedure

22

Cable/Wedge Socket Installation Procedure

23

Seals Replacement Procedure

24

Pump Unit Drawings

25

Warranty

26

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-1-

General Verification INSTALLATION MANUAL V3.3

Verify the following before commencing the installation: C Check the hoistway is square and plumbed C Check the actual dimensions of the hoistway against the general layout drawing supplied(width and depth) C Check the total travel (distance from floor level to floor level) C Check the pit depth C Check overhead C Check overhead space (the measurement from the top floor level to the underside of the ceiling) C Check the fixing points in hoistway where rail brackets mount. Before installing guide rail brackets, establish the cylinder and pillar bracket locations following dimensions shown on drawings. Ensure that they will not interfere with the rail brackets.

The Normal Operating Pressures For This Elevator Are: Capacity 600LBS 1000LBS

Static Psi 450 590

Working Psi 550 690

Relief Valve Psi 680 860

Delivery of material THESE ARE ESTIMATED READINGS AND ARE ONLY A GUIDE. READINGS MAY VARY FROM ABOVE VALUES ON EACH INSTALLATION.

Federal Elevator has taken every care to ensure that the equipment delivered to you will arrive in good condition. We recommend that you compare all components in the shipment against the shipping list. Should you find any shortages please call 1-905-458-4015 and ask for shipping. Any damage to crating should be reported to carrier immediately and a memo sent to us as soon as possible listing the damaged equipment.

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

- 2-

Federal Elevator Handicap Lift or Residence Lift -Suggested Installation Schedule The time taken to install these units will vary from project to project and will be dependent upon the following factors. C The number of floors served C The orientation of the unit, (Type A, B, C, OR D) C If auto or manual door operation is selected C The site conditions, and the experience of the installing team C Whether entrances are installed by elevator contractor or by others. It is very important that supervisors visit the site to verify all dimensions are correct and all services are available before the installing crew commences. If scaffold and power are not available then the job should not be started. Normally scaffold is required on day one and power is required to run the unit at the end of day one or beginning of day two. If possible make sure the contractor will be available to frame in around the entrances when required (usually day three - four). Following is a typical installation schedule using a two man team on a roped hydraulic unit serving two levels with front entry on both floors and having a manual door operation. Day one 1. Plumbing of hoistway 2. Installation of guide rail brackets 3. Installation of guide rails. Wash rails before installing car frame 4. Installation of hydraulic cylinder 5. Installation of controller 6. Installation of hydraulic power unit 7. Install hydraulic hose line from tank to cylinder 8. Wiring of power unit to controller Day two 1. Installation of car frame 2. Roping of car frame 3. Temporary running 4. Adjustment and test of safeties 5. Installation of platform 6. Wiring and piping of hoistway Day three 1. Start installing entrances 2. Finish installing entrances 3. Building of cab 4. Wiring of controller 5. Finishing of cab Day four 1. Adjusting locks and stops 2. Final adjustments

Persons 1 1 1&2 2 2 1&2 1 2 1&2 1&2 1&2 1 1&2 1&2 1&2 1&2 1&2 2 1&2 1&2 1&2

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-3-

Installation Procedure Install the guide rail brackets in the hoistway. The rails are attached with through bolts or anchors. For anchors, solid or concrete filled blocks are required. Through bolting can be used on concrete blocks or wooden structures.There are a minimum of three rail brackets, if installing a cable-hydraulic unit, plus two small ones of special design. One of these brackets is designed to attach near the top of the pillar and the other is designed to hold the top of the hydraulic cylinder. All the brackets are to be positioned at the spacings shown on the shop drawings. A plan view of the location of the brackets is shown on the shop drawings.

VERY IMPORTANT NOTE BECAUSE OF THE CLOSE TOLERANCES REQUIRED WITH THIS EQUIPMENT THE PLACEMENT OF THE GUIDE RAIL BRACKETS IS CRITICAL AS THERE IS LITTLE OR NO ADJUSTMENT ONCE THE RAILS ARE ATTACHED, THEREFORE YOU SHOULD PLUMB THE RAIL BRACKETS AS ACCURATELY AS POSSIBLE BEFORE THE INSTALLATION OF THE GUIDE RAILS.

Plumbing Of Rail Brackets To plumb the rails one must first determine the tightest point in the hoistway from the centre of the bracket to the hoistway wall. This will ensure that the car will have a clear hoistway when it is installed later. A plumb line is then dropped down this point the entire length of the hoistway and marked. At the same time the centre of all the rail brackets are also marked. The bracket centre points are lined up with the plumb line in the hoistway at their respective heights(see shop drawings) and installed. NOTE: After the installation is complete but before it is given to the owner for its use, the rails should be pinned to all the brackets by drilling and inserting a 1/4" bolt with flat washer, lock washer and nut at each bracket location.

2. Install the pit baseplate. This plate is to be secured to the floor after the installation of the car frame and fixing of the guide rails, ensure floor is clean and level before placing. Installation Of Rails 3. Install and plumb the guide rails. There is little adjustment on the brackets as per the above instructions.VERY IMPORTANT: You have been provided with 2 sets of rail dead stops. The set with the chain attached to them must be installed at approximately 5’6” from the bottom of the pit. The other set has to be installed at the highest point of the rails. THIS MUST BE DONE AT THIS POINT PRIOR TO CONTINUING WITH THE INSTALLATION.

4. Place the pillar on the pillar base and clamp to the pillar bracket provided. A more detailed view of this assembly can be seen in figure 1. Note: If the travel, pit and overhead are the same as those in the shop drawings, sheet 3 of 4, then the pillar has been already cut to the correct size needed for roping. If the pit or travel are significantly different then the pillar height may have to be altered accordingly.

Fig.1

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

- 4-

5. By inserting the cylinder mounting attachment (pillar cap) into the top of the pillar the cylinder is now ready to be installed. This pillar cap is manufactured off-centre. Install it so that the cylinder is closer to the wall and to the right when looking at it from the platform. 6. Attach the flow control valve and the oil line hose; note that the outlet is to be facing to the rear and towards the dead end of the ropes as seen in Figure 2. This must be done prior to installing the cylinder. Free flow must go to the cylinder and controlled flow to the pump unit. As well, ensure that the air bleeder at the top of the cylinder is facing to the front and to the side so as not interfere with the car frame. 7.

Fig.2

Install the cylinder on to the pillar cap. Attach the top of

the cylinder to the cylinder/rail bracket provided (see Figure 3.) ensuring that the clamp is approximately 5 inches below the cylinder head. Hand tighten the clamp but do not plumb the cylinder yet. Install the sheave assembly. Note that this assembly must be installed so that the cylinder is off-centre towards the wall and to the right (see note 5 above). Adjust the pillar bracket as necessary to plumb the cylinder. Tighten up the cylinder bracket. 8.

Before roping, the finished sling will have to be located at the under travel distance below the lowest landing. This distance is where the sling should be blocked off at for roping later on. (See Figure 4.)

Fig.3

9. The next item to install are the cross braces on the bottom of the sling. The guide shoes should have a clearance of 1/32" between each guide and rail face. Once the clearances are checked the cross braces and cross pieces can be tightened. Ensure that both legs of the sling are level and that the distance between the legs is constant. 10. Check to ensure the piston follower guide shoes are correctly adjusted. We recommend that they not be tightened until after the elevator has been ran up and down the hoist way a few times.

Fig.4

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-5-

11. Next install the rope shackles through the holes provided in the steel tee section on the pit base plate and lace the two 3/8" cables through the shackles, leaving 8" to 10" of rope tails, attach crosbies and cotter pins provided (See page 23 of this manual). 12. Pass the ropes over the sheave on the piston and back down behind the car sling to rest on the pit floor. Do not connect the ropes to the car sling at this stage. Should You Wish To Install The Carframe And Ropes Before Operating The Pump/ Motor The Piston May Have To Be Extended Manually And A Spacer Will Need To Be Placed To Obtain The Required Height. 13. Install the hydraulic power unit (see drawing on page 25) and fix the electric control panel to the machine room wall. Verify that the electrical supply is as required by the specifications and is compatible with the supplied equipment. Be sure to connect the neutral. Connect temporary controls to the temporary connections provided in the controller. 14. Read the wiring diagram before connecting motor and other equipment to the supply. A disconnect switch must be installed in the machine room to local requirements. Connect motor and valve to controller as shown on electrical prints. Connect main power and power to controller. 15. Connect the hydraulic hose line to the tank unit. It is recommended that you use Teflon tape on all fittings. Be careful not to block passage of oil with excess tape. 16. Fill the tank unit with Grade 32 hydraulic oil making sure the oil will cover the pump/motor unit completely. Check oil level again after the oil is pumped to the hydraulic cylinder *** Before Starting The Pump *** Close the gate valve on the tank unit Set the pressure relief valve to the minimum Ensure all the hydraulic line fittings are correctly attached Check that the motor is rotating in right direction 17. Push the contactors on the controller briefly to establish correct rotation of motor/pump unit. It is important to note that prolonged running of the pump in the wrong direction will cause damage to the pump unit.

WARNING It Is Advisable To Have More Than One Person On Site During This Start-Up Stage To Observe When The Cylinder Commences To Move Or If Any Line Joint Leakage Is Apparent.

18. With the gate valve still closed start motor, and slowly adjust pressure relief valve until it reads 25 kpa. Stop the motor and open the gate valve on the tank unit. Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

- 6-

19. Start the motor once again and slowly the oil will be pumped to the cylinder from the tank, the time taken for the oil to reach the cylinder can vary with each installation. 20. To bleed the air from the cylinder, with the system under pressure and the cylinder collapsed, slowly open the bleeder screw which is located at the top of the cylinder, close when all the air has been evacuated and the oil starts to exit. Caution: if the bleeder is opened too fast a rush of oil will come out of it. 21. Install the two rope shackles through the holes provided on the attachment plate and lace the cables through the cables leaving 8" to 10" (203mm to 254mm) of rope tails, do not cut the excess cable at this stage (See page 23 of this manual). 22. The first bottom rail dead stop should have already been installed prior to this point as per item 3 of the manual, to prevent any accidents. To drill the second hole drop the sling onto the first rail dead stop.Measure and drill the second hole and install the second unit.

IMPORTANT NOTES: The Car Sling Will Reach The Upper Most Floor Level With Some Over Travel Run The Car Up Slowly Until Sheave Assembly Hits The Rail Stops Car Sling And Follower Should Not Touch At Top Landing Car Sling And Follower Should Not Extend Past Top Of Rails

23. The next step is to install the top rail dead stops. These will prevent the sheave assembly from traveling past the top of the rails. 24. Lower the car by turning the emergency down valve located on the valve control block, you may wish to run the unit up and down the hoistway a few times to eliminate any remaining air. Bleed the cylinder again. 25. With the car at a comfortable working height near the pit, the adjustment of the safety device can be carried out. The safety rollers and block, although checked and preset in our factory before shipment may require further adjustment on site.

NOTE: DO NOT INSTALL CAB UNTIL THE SAFETIES ARE FULLY OPERATIONAL AND WEDGE SOCKETS IN CAB ARE ADJUSTED. Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-7-

26. (a)To adjust the safety device a load is required on the car sling, this is to compress the rope springs and allow the safety activating plate to be fully returned to its normal position. With the springs compressed and the plate in the normal position there should be a gap of around 1/16" between the knurled roller and the face of the guide rail, this should be the same for both sides. If any adjustment is required this can be achieved by loosening the screw and rotating until the required gap is attained. On completion of the adjustment make sure the screws are tightened. (b)Fix and adjust the safety/ slack cable switch bracket under the car sling to activate when rope extends and operates the lever arm. The sling requires a load until the car walls are installed. Otherwise the safety device may activate.The safety/slack cable switch is attached and prewired to the control wall. (c)To test the safety device run the car down and gently pull down lever arm, this will activate safety rollers and elevator will stop. To release safety device run car in the up direction. (d)With the springs fully collapsed, the threaded rods on the wedge sockets should be no more than 3/8" from the safety activating plate. 27.

The hoisting cables excess may now be cut off; do not forget to attach the crosbies and cotter pins provided.

NOTE: Your are ready now to start installing the platform and cab. We recommend that this work be done prior to the hall entrances being installed.

28. Raise the sling assembly to a sufficient point where the platform can be lifted onto the cantilever arms with the least of difficulty. 29. Place platform on the cantilever arms with the tabs on the underside of the platform aligned with wall is 10". This should give you a gap of approximately 2" between the platform and the sling upright. 30. Lock the cantilever arms in place by using the rail block provided. 31. From the underside of the platform insert the 3/8" hex head bolts through the tabs on the underside of the platform as they line up with the punched elongated holes on the cantilever arms. 32. Using the above noted bolts, appropriate nuts and washers provided hand tighten the platform to the cantilever arms. Ensure that the platform is level in both directions and the running clearance indicated in the General Layout is achieved at the floor sills. NOTE: Do not firmly tighten the platform at this time as you will have to make adjustments in your running clearances during further installation procedures later.

33. Place the control wall on the platform and line up the pre-drilled holes on the platform with the holes drilled in the 1" tube on the back side at the bottom of the control wall. Release the traveling cable from the back of the car station and drop it to the pit by ensuring that it passes to the left of the safety switch bracket. Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

- 8-

The traveling cable is long enough to go all the way to the controller after being attached to the half-way point in the hoistway. Release the limit switches from the back of the car station. Bring them over the top of the wall to the inside of the cab for now until you have the wall secured in place and then you can mount them on to the brackets provided that are attached to the top of this wall. Ensure that the limit switch wires (or flex for a public building installation) do not cross over the back of the car station as they have been pre-assembled and tested.Attach the safety/slack cable switch to its bracket. Adjust it so that its lever arm is operated when the cables become slack. 34. Align the tabs on the upper portion of the control wall with the tabs welded to the stiles. 35. Using the ½” x 6" threaded rods provided secure a ½” nut and washer on either side of each tab. Adjusting the nuts in or out will allow you to keep the critical 2" clearance between the edge of the platform and the stiles. 36. With the control wall in place you can now set the back wall in place. NOTE: if you have a type B cab go directly to step # 13. 37. Align the pre-drilled holes on the platform with the holes drilled in the 1" tubing on the lower portion of the back wall. Place the 1/4" bolts provided through the 1" tube as well as the platform and secure hand tight. 38. Align the pre-drilled holes on the upper portion of the side wall and the control wall and fasten with the 4" x 1/4" bolts provided. Repeat this procedure for the holes on the lower portion of the wall. 39. You may now attach the side wall by repeating the procedure in item #11. 40. Align the tie bar ceiling angles mounted on the back of the tie bar with the holes drilled in the side wall and control wall ceiling angles. Use the 2" x 1/4" bolts to secure the ceiling tie bar at each end. Repeat this procedure if your platform style is a type B. 41. Once all the fasteners are in place, proceed to square the cab so it is as plumb as possible. At this time secure all the fasteners so the cab is rigid. 42. Install all the switches on top of the cab by matching the legend in the limit switch with the legend in the bracket provided. All switches have been pre-assembled at the shop. Move the limit switches back on to the cab so that they will not be activated by the cams provided until the cams have been assembled.

43. If your cab has a gate, install it at this time. Remember that the gate has been pre-assembled so all holes will line up.

44. Install the limit switch cams on to the rails. They are all marked as to the floor they correspond. By using the temporary controls, move the cab on the constant pressure mode to each level and move the switches out on to the cams so that you ensure that the limit switches are properly activated at each landing. To verify that the anti-creep switch is working properly after all switches and cams have been finally adjusted, place the lift at any floor and lower it by using the manual lowering valve. Elevator should re-level after traveling ½” down. NOTE: At both terminal floors, elevator stops on limit switches. Set the stops by adjusting these switches.

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-9-

45. Install the cab ceiling and the lighting system. 46. If your platform does not have the finished floor attached, proceed to attach it now. Installing Landing Doors Supplied By Federal Elevator Systems Inc. 47. Installation of the landing doors can now be carried out. A maximum running clearance of 5/8" is required between the car sill and the landing sill. 48. If provided by Federal Elevator Systems Inc. the entrances are delivered as a single unit incorporating the door frame, the door, the inter-lock and the built in hall station. It is recommended the car cab be built before installation of the landing doors. This will allow the exact positioning of the doors and frame in relationship with the cab entrance. 49. Bring the elevator to the required floor level. Next move the entrance to the front of the cab and position it, allowing for the running clearance (see shop drawings) between the car sill and door frame, secure the steel sill to the floor with the screws provided. You will note that on the top of the door frame there are two square attachment plates with a hole in each, by inserting a bolt in these you can attach the frame to the supplied mounting brackets which in turn can be secured to the building structure. 50. The distance between the actual interlock and the side of the car frame is around 5/16", ensure you have this as a minimum dimension (see also Fig.5 ) 51. Install the door cam to the car (see Figure 6 next page) and proceed to adjust the door locks, if more than two doors per side, start with the intermediate floors and finish with the terminal floors.

Fig.5 52. Attach the two steel rail dead stop safety blocks to the guide rails in the holes drilled in the rails, for your safety. Use these pins each time when working under the elevator.

ATTENTION DO NOT FORGET TO REMOVE THESE PINS BEFORE RUNNING THE CAR Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-10-

53. Install car ceiling and all stickers as per code. 54. Install full load and check speed of platform lift. 55. Carry out valve adjustments as per instructions in this manual. Keep in mind that dirt is the most common enemy of a properly operating hydraulic circuit. Orifices and internal channels in the valve can be obstructed and impair or severely affect the control valve. 56. Perform A Safety Test as per page 22 of this manual. . 57. If your Pump Unit is provided with Low Pressure Switch, you might have to adjust it if your lift stops intermittently in the down direction. To adjust it, remove wire cap on switch, remove brass screw and insert an Allen key. By turning counterclockwise, you will be able to reduce the cut-off pressure.Do a quarter turn and verify operation. Continue until intermittent operation is no longer present.

Fig.6

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-11-

Handicap Lifts With Automatic Door Openers Fire rated entrance connections: Wire Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

Wire Colour Blue (White) Blue (Black) Orange (Black) Orange (Red) White (Black) White (Red) Black (White) Black (Red) Green (White) Green (Black) White Black Blue Red Orange Blue (Red) Red (Black) Pink (White) Green

Connected To Lock Lock Pre-Lock Pre-Lock Key-Switch N.O. Contact Key-Switch N.O. Contact Call Button N.O. Contact Call Button N.O. Contact Call Button N.O. Contact Call Button N.O. Contact Electric Striker Electric Striker Arrival Light Arrival Light Digital P.I. Or Miscellaneous Digital P.I. Or Miscellaneous Digital P.I. Or Miscellaneous Ground Digital P.I. Or Miscellaneous

NOTES: 1. Depending on the installation features, not all the wires will be connected. e.g.: If power entrances are not provided, then electric striker will not be installed and therefore, not wired. 2. Your entrances have been pre-assembled, tested, and inspected. 3. Report any discrepancies to the factory immediately after receiving the equipment. 4. For special button arrangement, this distribution of wires can be modified.

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-12-

Maintenance Requirements The schedule for maintenance on this unit is to be arranged by the local service company, however, it is recommended that the following inspections and adjustments (if required) be carried out at regular intervals not exceeding 90 days. Check the machine room for the following: Check the tank unit for the following: 1. Oil leakage around the control valve 2. Oil leakage at hydraulic hose joints 3. Minimum oil level when lift is at top floor 4. Tank is clean and dry 5. Check expiry date of hose line Check the controller for the following: 1. Loose terminal connections 2. Burnt or frayed wiring 3. Excessive dust buildup 4. Loose relays and bases 5. Controller is clean 6. Emergency battery has not exceeded expiry date Inspect the hoist way for the following: Check the hoist way for the following: 1. Guide rail brackets are secure 2. Guide rails and clips are secure 3. All limit switches are secure 4. Light and outlet are functioning 5. All piping and fittings are secure 6. Pit is clean and dry 7. Hoisting ropes are undamaged 8. Rope attachments and crosbies are secure 9. Sufficient lubrication for guide rails Inspect the hydraulic piston for the following: 1. Scratches to piston 2. Excessive oil leakage around wiper seal 3. Ensure that oil return hose is connected if one supplied 4. Cylinder and pillar brackets are secure

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-13-

Maintenance Requirements (cont’d) Inspect the piston follower for the following: 1. Piston follower guide shoes are secured 2. Sufficient lubrication to the guide shoes 3. Piston follower is level Test The Safety Device On Each Visit (See page 21 of this manual) Inspect the top of car for the following (if cab top provided): 1. Ensure all attachments are secure 2. Trail cables are hanging properly 3. Conduits and piping are not damaged 4. Car top is clean and dry Inspect the door frames for the following: 1. All frames are secure and not damaged 2. Door lock box is attached firmly 3. Door release roller arm is tightly secured 4. Door hinges are lubricated 5. Door view panel is intact Inspect each landing entrance for the following: 1. Button face plate is secure 2. Call buttons are operating as normal 3. Door lock and keeper are aligned and secure Inspect the inside of the car for the following: 1. Lights are working 2. Face plate secure 3. All indicator lights and buttons are functioning 4. All walls and handrails are secured 5. Telephone (if installed) is working 6. Emergency light works (disconnect power to test) 7. Check floor level stops for accuracy

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-14-

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-15-

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-16-

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-17-

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-18-

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-19-

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-20-

Operation Instructions From Outside The Elevator ·

To run the elevator from the hall station install the key (if applicable) and turn to run position

·

Push and hold the call button until the elevator arrives at the floor

·

Maintain the button in the pressed position (for automatic)

·

Remove the key (if applicable) and enter the elevator

Operation Instructions From Inside The Elevator ·

To run the elevator from the platform install the key (if applicable) and turn to run position

·

Push and hold the required floor button until floor level is reached

·

Push the door open button (automatic door only) remove the key (if applicable)

·

Exit the lift

Trouble Shooting Procedures 1. Locate the building manager for access to lift pump room 2. Locate the elevator and inspect for any damages to the equipment 3. Inspect each key switch for damage and they are in the off position 4. Test the elevator door halls that all are closed and locked 5. With the proper meter determine that the main line voltage is correct and check the main fuses. 6. Check the position of the motor overload device if in the off position, look for poor connections at control or motor or a failure in any of the main contactors. 7. Test all fuses in the controller with the proper meter. If any fuses are open, check the wiring print to determine the cause and location of the circuit and switches. 8. Test the hoistway circuit to determine if any switches are open with the proper meter (do not under any circumstances jump out any part of these circuits with a jumper wire or by any other tool). 9. If the elevator will go down but not up check the ‘UP’ terminal switch. 10. If the elevator will go up but not down check the ‘DN’ terminal switch and down coil. 11. Call Federal Elevator Systems Inc. (1-905-458-4015) if none of the above rectifies the problem. Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-21-

SAFETY TEST PROCEDURE NOTES: IF THIS IS A FULL LOAD TEST ENSURE THAT THE FULL RATED CAPACITY EQUIVALENT IS ON THE PLATFORM IN THE FORM OF TEST WEIGHTS. IT IS A GOOD IDEA TO REMOVE THE CEILING TILES PRIOR TO COMMENCING THIS TEST. 1) CALL THE ELEVATOR TO THE SECOND LANDING. USING THE HOISTWAY ACCESS DEVICE ENTER THE HOISTWAY AT THE FIRST LANDING. TURN OFF THE PIT SWITCH. 2) PLACE A 4" X 4" WOODEN POST UPRIGHT ON THE PIT FLOOR. THIS POST IS TO BE CUT

TO THE APPROPRIATE TEST LENGTH. LOWER THE ELEVATOR ON TO THE 4" X 4" PROP AND ALLOW THE HOISTING CABLE(S) TO BECOME SLACK BY APPROXIMATELY 6 INCHES. THIS CAN BE ACCURATELY DETERMINED BY MARKING THE SHEAVE GUIDE POSITION ON THE WALL. THE ROPE IS 2:1 THEREFORE WHEN THE PISTON HAS MOVED DOWNWARD INCHES YOU HAVE ACHIEVED 6 INCHES OF SLACK ROPE. 3) EXIT THE HOISTWAY AND SECURE THE LOWEST LANDING DOOR IN THE OPEN POSITION. 4) IF YOU WISH TO MEASURE THE SAFETY STOPPING DISTANCE MARK THE LOCATION OF THE PLATFORM SURFACE ON A CONVENIENT REFERENCE SURFACE ( A PENCIL MARK ON THE DOOR FRAME WORKS WELL AND CAN BE REMOVED). 5) USE ANOTHER LENGTH OF WOOD TO KNOCK THE 4" X 4" SUPPORT OUT FROM UNDER THE CAR SLING BY HITTING THE PROP AT IT’S BASE. THE CAR WILL COME TO REST ALMOST IMMEDIATELY ON THE CAR SAFETIES. THE ROPES WILL REMAIN SLACK. THIS WILL HAVE DEMONSTRATED THE ABILITY OF THE SAFETIES TO STOP AND HOLD THE GROSS LOAD. 6) IF YOU WISH TO MEASURE THE STOPPING DISTANCE MEASURE THE DISTANCE BETWEEN THE “REST” POSITION OF THE PLATFORM AND THE ORIGINAL REFERENCE LINE MADE. 7) RE-SET THE SAFETIES BY DRIVING THE ELEVATOR IN THE UP DIRECTION. THIS WILL ALSO RE-SET THE SAFETY PLANK SWITCH. 8) VERIFY THAT THE CABLE(S), CABLE FASTENING(S), AND SAFETIES HAVE RETURNED TO THEIR PROPER POSITIONS AND REMOVE ALL PLATFORM SUPPORTING PROPS (AND ANY OTHER MATERIALS NOT NORMALLY IN THE PIT) FROM THE PIT. INSPECT ALL EQUIPMENT TO ENSURE THAT PROPER CONDITIONS EXIST. 9) TURN ON THE PIT SWITCH AND CLOSE THE BOTTOM DOOR. TEST THE COMPLETE OPERATION OF THE ELEVATOR AND, WHEN SATISFIED, RETURN THE ELEVATOR TO SERVICE.

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-22-

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-23-

INSTRUCTIONS TO REPLACE SEALS IN HYDRAULIC CYLINDER PRIOR TO PROCEEDING TO CHANGE SEALS, LOOK FOR MARKS IN THE PISTON. IF FOUND, SAND THEM UNTIL THE SURFACE OF THE PISTON IS SMOOTH AND FREE OF PROTRUSIONS THAT COULD CUT THE SEALS. ONLY AFTER YOU ARE SATISFIED THAT THIS HAS BEEN DONE, FOLLOW THESE STEPS: 1. LIFT THE CAR UP TO HAVE ENOUGH ROOM FOR REMOVING THE CYLINDER HEAD AND CHANGE THE SEALS. 2. SECURE THE CAR IN PLACE USING THE RAIL STOPS PROVIDED. ONCE THE CAR IS SECURELY IN PLACE, REMOVE POWER TO THE PUMP UNIT BY TURNING POWER OFF AT THE DISCONNECT SWITCH. 3. UNSCREW THE BOLT THAT HOLDS THE PISTON TO THE CAR. 4. OPEN THE MANUAL LOWERING VALVE UNTIL THE PISTON IS FULLY RETRACTED. 5. CLOSE THE SHUT-OFF VALVE AT THE PUMPING UNIT TO ENSURE THAT OIL WILL NOT COME OUT. 6. DISCONNECT THE LEECH CONNECTOR AND LINE. 7. REMOVE THE HEAD: IN CASE OF BOLTED HEAD, USE TWO BOLTS AND SCREW THEM IN THE HOLES LOCATED TO EACH SIDE OF THE HEAD SO THAT IT WILL BE EASY TO REMOVE THE HEAD. IN CASE OF SCREWED HEAD, USE CHAIN ?VISEGRIP? TO UNSCREW COUNTERCLOCKWISE. 8. IN CASE OF SCREWED HEAD, UNSCREW THE BRASS GLAND. 9. REMOVE THE OLD SEALS, INSTALL THE NEW SEALS AND PUT A LOT OF GREASE ON THEM. 10. IN CASE OF SCREWED HEAD, RE-SCREW TO MAXIMUM THE GLAND WITH NO SPACE BETWEEN THE GLAND AND THE HEAD. 11. REPLACE AND GREASE THE O’RINGS. 12. REINSTALL THE HEAD. 13. CLOSE THE MANUAL LOWERING VALVE. 14. REINSTALL LEECH CONNECTOR AND LINE ON THE HEAD. 15. OPEN THE SHUT-OFF VALVE OF THE PUMPING UNIT. 16. TURN POWER ?ON? AT THE DISCONNECT SWITCH. 17. RAISE THE PISTON WITH ADEQUATE HEIGHT. 18. OPEN THE BLEEDER VALVE UNTIL OIL APPEARS AND CLOSE TIGHTLY BY HAND. 19. RE-ATTACH PISTON TO CAR . 20. TEST CYLINDER BY RAISING AND LOWERING CAR AT LEAST 10 TIMES AND VERIFYING THAT NO SIGNIFICANT AMOUNT OF OIL IS COMING THROUGH THE SEALS.

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-24-

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680

-25-

WARRANTY Starting from the date of shipment from the Factory, Federal Elevator will either repair or replace at its option and to the original purchaser only, any part or parts found to be defective in material or workmanship or both for a period of one (1) year. This warranty shall not apply to any part or component found to be defective or inoperative due to normal wear and tear, misuse, accident or neglect, acts of nature, improper installation or maintenance, alterations, or when used in conjunction with materials supplied by others. This warranty shall not apply where the elevator or any component has been used in a manner contrary to that for which it was designed. No warranty is made for another party’s labor or expenses associated with installation, service, maintenance or repair. The installation of the Federal Elevator equipment must be in accordance with the applicable Codes and with Federal Elevator instructions. All equipment furnished by Federal Elevator must be installed, serviced and maintained by a qualified, licensed and insured elevator contractor following Federal Elevator recommendations. Federal Elevator reserves the right to request any Certificates for licenses and insurance at any time. If, in the sole opinion of Federal Elevator, a component is found defective and in need of repair or replacement, said component must be shipped prepaid to the destination selected by Federal Elevator. A repaired or replacement component will be shipped collect to the original purchaser. Federal Elevator will be the sole judge of any remedies required under this Warranty. This Warranty does not cover any installation or travelling costs required to remove and/or replace defective components. This is the exclusive remedy, there is no other express or implied Warranty. Liability for consequential damages under this or any other warranty is specifically excluded to the extent exclusion is permitted by law.

FEDERAL ELEVATOR

Richard Piatti,P.Eng. Director

Federal Elevator 187 Deerhurst Drive Unit #1 Brampton, Ontario Canada L6T 5K3 Ph:(905)458-4015 Fax:905)458-0680