REPUBLIC OF THE PHILIPPINES
OFFICE OF THE BUILDING OFFICIAL GENERAL NOTES:
B
A
ALL ELECTRICAL WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH THE PROVISION OF THE LATEST APPROVE EDITION OF THE PHILIPPINE ELECTRICAL CODE, THE LAWS AND ORDINANCES OF THE LOCAL CODE ENFORCING AUTHORITIES AND REQUIREMENTS OF THE LOCAL POWER AND TELEPHONE COMPANY. 1. SERVICE POWER SHALL BE 230V, SINGLE PHASE, 2-WIRES WITH GROUND, 60Hz SYSTEM.
A
B
C
D
C
D
E
E District/City/Municipality
WCO
t
PARENT'S BEDROOM
1
CO
WH
1
3. SMALLEST BRANCH CIRCUIT WIRE SHALL BE 3.5mm² THHN FOR LIGHTING AND POWER SYSTEM, UNLESS OTHERWISE STATED IN THE PLAN, IN RACEWAY 15mm TRADE SIZE CONDUIT, WIRE SHALL BE INSULATED FOR 600 VOLTS.
T&B-1
WCO
2
CO
CO
HALLWAY CO
CO
LP-7
KITCHEN
LP-18 CO
6. ALL FLUORESCENT LAMP SHALL BE PRE-HEAT TYPE, WITH HIGH POWER FACTOR BALLAST, CAPACITOR AND SPRING LOADED LAMP HOLDERS.
CO
Sb Sg
3
S3Wg
CO
m
7. ALL LIGHT-CONTROLLED SWITCHES SHALL BE RATED 15 AMPS, 220 VOLTS AC ONLY, SWITCHES SHALL BE INSTALLED FOR WITH HORIZONTAL MOTION.
m
LIVING AREA
LIVING AREA
KITCHEN
LP-2
Srs Spq
p
k
DINNING AREA
u
PORCH
Skl
LP-1
S3Wmn
LP-4
DINNING AREA
b
g
CO CO
c
Sa
2
CO
CO
HANNAH'S BEDROOM
S3e
HANNAH'S BEDROOM
CO
RA
3
5. WHENEVER NECESSARY PULLBOX OF PROPER SIZE AND DIMENSION SHALL BE PROVIDED ALTHOUGH NOT INDICATED IN THE PLAN. ALL JUNCTION BOXES SHALL BE PROVIDED WITH METAL PLATE COVER.
CO
CO
S3e
a
CO
4. ALL BRANCH CIRCUIT HOMERUN SHALL BE INSTALLED AS INDICATED IN THE PLAN. EXPOSED CIRCUIT RUN SHALL BE PARALLEL TO OR PERPENDICULAR WITH THE BUILDING LINE AND SUPPORTED BY CONDUIT CLAMPS EVERY 1.5 METERS. DIAGONAL CONDUIT RUN SHALL NOT BE ACCEPTED.
Sc
e
PARENT'S BEDROOM
W.I.C.
CO
LP-11
W.I.C.
T&B-1
CO
CO
CO
CO
WCO
2. WIRINR METHOD SHALL BE DONE IN PVC CONDUIT FOR LIGHTING, POWER, TELEPHONE AND AUXILIARY SYSTEM UNLESS OTHERWISE INDICATED IN THE PLAN.
r
PORCH
g
q
LP-5 LP-6
4 LP-13
BEDROOM 1
CO
CO
BEDROOM 1
LP-12
5
LP-3
S3Wg
HALLWAY
6
a. LIGHT-CONTROLLED SWITCHES ---------- 1.40 M. ABOVE FLOOR FINISH AT CENTER b. DUPLEX CONVENIENCE OUTLET ---------- 0.30 M. ABOVE FLOOR FINISH AT CENTER c. TELEPHONE OUTLET --------------------------- 0.30 M. ABOVE FLOOR FINISH AT CENTER d. PANELBOARDS ----------------------------------- 1.40 M. ABOVE FLOOR FINISH AT CENTER UNLESS OTHERWISE INDICATED BY THE FIELD CONDITIONS.
Se Sm m
d m
T&B-2
u CO
13. MOUNTING HEIGHT NOT SHOWN ON SCHEDULE ARE AS FOLLOWS:
BEDROOM 2
BEDROOM 3
a
Sd Su
BEDROOM 3
CO
CO
CO
12. ALL RECEPTACLE OUTLET SHALL BE PROPERLY GROUNDED TO THE BOX BY MEANS OF GROUNDING LUGS.
p
Sa
WH
11. ALL BOXES SHELL BE MADE OF CODE GAUGE STEEL WITH ZINC CHROMATE PROTECTION.
LP
CO
CO
l
S3Wmn
4
HALLWAY LP-9
WCO
5
CO CO CO CO
CO
LP-6
CO
10. ALL MATERIALS TO BE USED SHALL BE NEW AND APPROVED TYPE FOR THE LOCATION AND PURPOSES.
PB
CO
9. ALL METALLIC CONDUIT, CABINET, BOXES AND EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED.
CO
n
Stuv
WCO
CO
n
LP-8
CO
8. ALL PANELBOARD SHALL BE PROVIDED WITH SOLID GROUNDING BUS WITH TERMINALS.
BEDROOM 2
6
CO
v
s
WCO
14. THE ELECTRICAL CONTRACTOR SHALL SECURE ALL WIRING PERMITS AND ALL FEES REQUIRED FOR THE WORK AND SHALL FURNISH THE OWNER THROUGH THE ENGINEERS FINAL CERTIFICATES OF ELECTRICAL INSPECTION AND APPROVAL FROM PROPER GOVERNMENT AUTHORITIES FOR COMPLETE WORK.
1 CONVENIENCE OUTLET LAYOUT A-2 E-1
2 LIGHTING LAYOUT
1 : 100
A-2 E-1
15. THE ELECTRICAL CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWING FOR THE EXACT LOCATION AND MOUNTING HEIGHT OF ALL VISIBLE WIRING DEVICES, FIXTURES AND THE LIKES.
A
B
C
D
1 : 100
E
16. ALL ELECTRICAL WORKS HEREIN SHALL BE DONE UNDER THE DIRECT AND IMMEDIATE SUPERVISION OF A DULY QUALIFIED LICENSED ELECTRICAL ENGINEER OR MATER ELECTRICIAN. ALL MOUNTING HEIGHTS ARE SUBJECT TO THE APPROVAL OF THE ARCHITECT/OWNER.
1 TEL
T&B-1
W.I.C.
CA
PARENT'S BEDROOM
2
HANNAH'S BEDROOM
CTB
TEL
CA
LEGEND:
TTB
3
CTB
ELECTRICAL FIXTURES LEGEND
RCP LEGEND
CO
PL
CONVENIENCE OUTLET
PINLIGHT WCO
KITCHEN
WEATHERPROOF OUTLET ONE-GANG SNAP SWITCH
Sa
DINNING AREA
RA
LIVING AREA
RANGE OUTLET
PORCH
REF
Sabc
REFRIGERATOR OUTLET
CTB
TEL
CTB
TELEPHONE OUTLET
THREE-GANG SNAP SWITCH
CTB
4
CA
CABLE TV OUTLET
TWO-WAY SNAP SWITCH
LIGHT AND POWER PANEL TTB
POWER LINE
CTB
5
TELEPHONE TERMINAL BOIX
TTB CTB
BEDROOM 1
CA
BEDROOM 3
TEL
CATV TERMINAL BOX
BEDROOM 2 LIGHTING WIRE LINE
T&B-2 TEL
6
CIRCUIT BREAKER
CTB
CA
GROUNDINGS ENTRANCE
3 AUXILIARY LAYOUT A-2 E-1
SEAL
ENGR. PASCUAL P. FERRER PROFESSIONAL ELECTRICAL ENGINEER ENGINEER
ADDRESS
PRC No.:
2757
PTR No.:
1598261
Date:
JAN. 02, 2014
Place:
PAKIL, LAGUNA
REPUBLIC ACT 9266 SEC. 33 THESE DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS, DULY SIGNED, STAMPED OR SEALED AS INSTRUMENT OF SERVICE, ARE INTELLECTUAL PROPERTY AND DOCUMENTS OF THE ARCHITECT, WETHER THE OBJECT FROM WHICH THEY ARE MADE EXECUTED OR NOT, IT SHALL BE UNLAWFUL FOR ANY PERSONS TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS OR BUILDING, EXECUTED PARTLY OR IN WHOLE WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS
1 : 100
PROJECT & LOCATION:
OWNER:
SHEET CONTENTS:
PROPOSED:
FABILA RESIDENCE LOT 152, LO-ONG, CONCEPCION, ILOILO PROVINCE
MS. HANNAH MAE C. FABILA
SHEET NO.:
LIGHTING, CONV. OUTLET, & AUXILIARY LAYOUT, GENERAL NOTES, & LEGEND
DRAWN:
CHECKED:
DATE:
02/05/14
E-1 PROJ. NO.:
0011
FOR BUILDING PERMIT
SW
TEL CA
TO TELEPHONE SERVICE ENTRANCE
CA LP
TO CATV SERVICE ENTRANCE
TTC
02/05/14
TWO-GANG SNAP SWITCH
Sab
L1
REPUBLIC OF THE PHILIPPINES
L2
OFFICE OF THE BUILDING OFFICIAL
LOAD SCHEDULE AND COMPUTATION MAIN:
PANEL: LP MOUNTING: FLUSH MOUNTED LOCATION: KITCHEN
100AT, 2P, 230V, 60HZ. CKT. BREAKER IN NEMA 1 ENCLOSE 2 - 30mm² THHN & 1 - 8.0mm² TW GND. WIRE IN 1 - 25mm DIA. RSC / 32mm DIA. PVC PIPE
USE:
2P, 100AT 2P,15AT
CRK. BREAKER CKT. NO
DESCRIPTION
VOLT
VA
AMP P
AT
AF
SIZE OF CONDUCTOR
SIZE OF CONDUIT
1
LIGHTING OUTLETS (HANNA'S/T&B/PARENT'S
230
250
1.09
2
15
50
2 - 3.5 mm² THHN & 1 - 2.0 mm² TW GND
20mm Ø PVC
2
LIGHTING OUTLETS (LIVING/DINING/PORCH
230
400
1.74
2
15
50
2 - 3.5 mm² THHN & 1 - 2.0 mm² TW GND
20mm Ø PVC
3
LIGHTING OUTLETS (GUEST/BEDROOM 1&2/T&B)
230
250
1.09
2
15
50
2 - 3.5 mm² THHN & 1 - 2.0 mm² TW GND
20mm Ø PVC
4
LIGHTING OUTLETS (KITCHEN/LAUNDRY/UTILITY)
230
350
1.52
2
15
50
2 - 3.5 mm² THHN & 1 - 2.0 mm² TW GND
20mm Ø PVC
5
CONVENIENCE OUTLETS (KITCHEN)
230
540
2.35
2
20
50
2 - 3.5 mm² THHN & 1 - 3.5 mm² TW GND
20mm Ø PVC
6
CONVENIENCE OUTLETS (KITCHEN)
230
720
3.13
2
20
50
2 - 3.5 mm² THHN & 1 - 3.5 mm² TW GND
20mm Ø PVC
7
CONVENIENCE OUTLETS (HANNA'S/T&B/PARENTS)
230
2160
9.39
2
20
50
2 - 3.5 mm² THHN & 1 - 3.5 mm² TW GND
20mm Ø PVC
8
CONVENIENCE OUTLETS (LIVING/DINING)
230
2160
9.39
2
20
50
2 - 3.5 mm² THHN & 1 - 3.5 mm² TW GND
20mm Ø PVC
9
CONVENIENCE OUTLETS (BEDROOM 2/T&B)
230
1080
4.70
2
20
50
2 - 3.5 mm² THHN & 1 - 3.5 mm² TW GND
20mm Ø PVC
10
CONVENIENCE OUTLETS (BEDROOM 1/GUEST)
230
1440
6.26
2
20
50
2 - 3.5 mm² THHN & 1 - 3.5 mm² TW GND
20mm Ø PVC
11
WATER HEATER 1 (T&B)
230
3000
13.04
2
30
50
2 - 3.5 mm² THHN & 1 - 3.5 mm² TW GND
20mm Ø PVC
12
WATER HEATER 2 (BEDROOM 2)
230
3000
13.04
2
30
50
2 - 5.5 mm² THHN & 1 - 5.5 mm² TW GND
20mm Ø PVC
13
ACU 0.75 HP (BEDROOM 1)
230
720
3.13
2
20
50
2 - 5.5 mm² THHN & 1 - 5.5 mm² TW GND
20mm Ø PVC
14
ACU 0.75 HP (BEDROOM 2)
230
720
3.13
2
20
50
2 - 3.5 mm² THHN & 1 - 3.5 mm² TW GND
20mm Ø PVC
15
ACU 0.75 1 HPHP (HANNA'S (GUESTROOM) ROOM)
230
720
3.13
2
20
50
2 - 3.5 mm² THHN & 1 - 3.5 mm² TW GND
20mm Ø PVC
16
ACU 0.75 HP (PARENT'S ROOM)
230
720
3.13
2
20
50
2 - 3.5 mm² THHN & 1 - 3.5 mm² TW GND
20mm Ø PVC
17
ACU 1 HP (HANNA'S ROOM)
230
950
4.13
2
20
50
2 - 3.5 mm² THHN & 1 -3.5 mm² TW GND
20mm Ø PVC
18
ELECTRIC RANGE (KITCHEN)
230
2680
11.65
2
30
50
2 - 5.5 mm² THHN & 1 - 5.5 mm² TW GND
20mm Ø PVC
19
CONVENIENCE OUTLETS (LAUNDRY AREA/UTILITY)
230
360
1.56
2
20
50
2 - 3.5 mm² THHN & 1 - 3.5 mm² TW GND
20mm Ø PVC
20
SPARE
230
2
15
50
------------
20mm Ø PVC
21
SPARE
230
2
20
50
------------
20mm Ø PVC
22
SPARE
230
2
30
50
------------
20mm Ø PVC
LIGHTING OUTLETS (HANNA'S/T&B/PARENT'S
1 2P,15AT
LIGHTING OUTLETS (GUEST/BEDROOM 1&2/T&B)
TOTAL
22220
CONVENIENCE OUTLETS (HANNA'S/T&B/PARENTS)
CONVENIENCE OUTLETS (BEDROOM 2/T&B)
WATER HEATER 1 (T&B)
ACU 0.75 HP (BEDROOM 1)
ACU 0.75 HP (GUEST ROOM)
ACU 1 HP (HANNA'S ROOM)
8
CONVENIENCE OUTLETS (LIVING/DINING)
10
CONVENIENCE OUTLETS (BEDROOM 1/GUEST)
12
WATER HEATER 2 (BEDROOM 2)
14
ACU 0.75 HP (BEDROOM 2)
16
ACU 0.75 HP (PARENT'S ROOM)
18
ELECTRIC RANGE (KITCHEN)
20
SPARE
22
SPARE
2P,30AT
17 2P,20AT
CONVENIENCE OUTLETS (KITCHEN)
2P,20AT
15 2P,20AT
6
2P,20AT
13 2P,20AT
LIGHTING OUTLETS (KITCHEN/LAUNDRY/UTILITY)
2P,30AT
11 2P,20AT
4
2P,20AT
9 2P,30AT
LIGHTING OUTLETS (LIVING/DINING/PORCH
2P,20AT
7 2P,20AT
2
2P,20AT
5 2P,20AT
District/City/Municipality
2P,15AT
3 2P,20AT
CONVENIENCE OUTLETS (KITCHEN)
2P,15AT
2P,15AT
96.61
CONVENIENCE OUTLETS (LAUNDRY AREA/UTILITY)
LP = (96.61 A x 0.80 DF) + (1.5 x 4.13 A) = 83.84 A (USE 100ATAFCB)
19 2P,20AT
ILp= (96.61A x 0.80DF) +1.5 x4.13A = 83.84A Use 100AT100AFCB
SPARE
2P,30AT
21
POWER SERVICE ENTRANCE 1 DIA. 2 WIRE + GROUND, 230 VAC, 60 HZ
2 - 30 MM THHN COPPER & 1 - 8.0 MM TW COPPER IN 1 - 25 MM DIA. PVC
PANEL LP (KITCHEN)
1 PANEL DETAIL (LP) E-2
02/05/14
KILOWATT - HOUR METER
1700 (VERIFY)
M
NTS
2 - 30 MM THHN COPPER & 1 - 8.0 MM TW COPPER IN 1 - 32 MM DIA. PVC
2 POWER SINGLE LINE DIAGRAM E-2
NTS
SEAL
ENGR. PASCUAL P. FERRER PROFESSIONAL ELECTRICAL ENGINEER ENGINEER
ADDRESS
PRC No.:
2757
PTR No.:
1598261
Date:
JAN. 02, 2014
Place:
PAKIL, LAGUNA
REPUBLIC ACT 9266 SEC. 33 THESE DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS, DULY SIGNED, STAMPED OR SEALED AS INSTRUMENT OF SERVICE, ARE INTELLECTUAL PROPERTY AND DOCUMENTS OF THE ARCHITECT, WETHER THE OBJECT FROM WHICH THEY ARE MADE EXECUTED OR NOT, IT SHALL BE UNLAWFUL FOR ANY PERSONS TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS OR BUILDING, EXECUTED PARTLY OR IN WHOLE WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS
PROJECT & LOCATION:
OWNER:
SHEET CONTENTS:
PROPOSED:
FABILA RESIDENCE LOT 152, LO-ONG, CONCEPCION, ILOILO PROVINCE
MS. HANNAH MAE C. FABILA
SHEET NO.:
SCHEDULE OF LOAD, SIGLE LINE DIAGRAM, & PANEL DETAIL
DRAWN:
CHECKED:
DATE:
02/05/14
E-2 PROJ. NO.:
0011
FOR BUILDING PERMIT
FFL