21 – AIR CONDITION NOTE: reset C/B´s during 10 sec, at least, unless otherwise specific
ECAM WARNING
SYSTEM RESET
AIR PACK 1(2) FAULT or OVHT or OFF PACK 1 + 2 FAULT
OVHT temp’s Pack outlet temp. ≥ 95 C Pack compres. Outlet temp. ≥ 26 C FAULT LIGHT goes out when OVHT disapears
PACK 1(2) REGUL FAULT
For all of these ECAM WARNING’s (FAULTs) PACK 1 and 2 OFF. After 30 sec. reset C/B’s during 2 min Pack 1→ X21, X22, Y18, Y19 Pack 2→ W21 W22, Y20, Y21 AUTO TEST 30 sec. PACK 1 and 2 ON
FWD CRG VENT FAULT (if installed)
C/B’s: C7, T22 AUTO TEST 30 sec. C/B’s: C7, S22 AUTO TEST 30 sec.