ECAM WARNING / SYSTEM RESET

21 – AIR CONDITION NOTE: reset C/B´s during 10 sec, at least, unless otherwise specific

ECAM WARNING

SYSTEM RESET

AIR PACK 1(2) FAULT or OVHT or OFF PACK 1 + 2 FAULT

OVHT temp’s Pack outlet temp. ≥ 95 C Pack compres. Outlet temp. ≥ 26 C FAULT LIGHT goes out when OVHT disapears

PACK 1(2) REGUL FAULT

For all of these ECAM WARNING’s (FAULTs) PACK 1 and 2 OFF. After 30 sec. reset C/B’s during 2 min Pack 1→ X21, X22, Y18, Y19 Pack 2→ W21 W22, Y20, Y21 AUTO TEST 30 sec. PACK 1 and 2 ON

FWD CRG VENT FAULT (if installed)

C/B’s: C7, T22 AUTO TEST 30 sec. C/B’s: C7, S22 AUTO TEST 30 sec.

AFT CRG VENT FAULT (if installed)

COND CKPT (FWD CAB) (AFT CAB) (FWD CRG) (if Installed) DUCT OVHT AFT CRG DUCT OVHT (if Installed)

OVHT Temp: Duct Temp. ≥ 80º C FAULT LIGHT goes out when Duct temp.