E-terraControl V3.4 & PACIS V4.2_A
Short Description
e-terra...
Description
CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
E-terraControl V3.4 & PACiS V4.2 Integration Guide
DISTRIBUTION Confidentiality Category Restricted
Control Category
Normal
Controlled
Not Controlled
Identification number
Identification letters
Issue
Transmission & Distribution
2059660
IG
A
AREVA T&D PCL, Avenue de Figuières – BP75 34975 Lattes Cedex - France
CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
Intended blank page
AREVA PACIS E-terraControl V3.4 & PACIS V4.2_A Installation & Configuration Guide - Issue A – 17/11/06
Identification Number: 2059660
Page: 2 / 21
CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
APPROVAL SIGNATURES
NAME
POSITION
J-M BOISSET
PACIS PROJECT MANAGER
M. VERNEY
R&D GROUP MANAGER VALIDATION & SUPPORT
DATE
SIGNATURE
RECORD OF REVISION
ISSUE
DATE
Z A
COMMENTS
24/02/06
AUTHOR JP. MALRIC
17/11/06
JP. MALRIC
First issue
AREVA PACIS E-terraControl V3.4 & PACIS V4.2_A Installation & Configuration Guide - Issue A – 17/11/06
Draft
Identification Number: 2059660 Page: 3 / 21
CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
TABLE OF CONTENTS 1.
INTRODUCTION .........................................................................................................................................6
1.1 1.2 1.3 1.4 1.5 1.6 2.
DOCUMENT OBJECTIVE ........................................................................................................................6 WHO SHOULD USE THIS DOCUMENT ...........................................................................................................6 OPERATING SYSTEM SUPPORT .....................................................................................................................6 REFERENCE DOCUMENTS ....................................................................................................................6 ABBREVIATIONS ....................................................................................................................................7 COMPATIBILITY ...........................................................................................................................................7 INSTALLATION ..........................................................................................................................................8
2.1 E-TERRACONTROL V3.4...............................................................................................................................8 2.2 PACIS COMMUNICATIONS AGENCY V3.22A ...............................................................................................8 2.2.1 Installing the communications Agency ...................................................................................................8 2.2.2 Installing SISCO MMS driver software ..................................................................................................8 2.2.3 IEC61850 Client needs Anonymous RPCs with Service Pack 2 ...........................................................10 3.
CONFIGURATION ....................................................................................................................................11
3.1 PURPOSE ....................................................................................................................................................11 3.2 IEC 61850 .................................................................................................................................................11 3.2.1 Agency application ...............................................................................................................................11 3.2.2 IEC 61850 Configuration .....................................................................................................................12 3.2.3 IEC 61850 Client ..................................................................................................................................14 3.3 E-TERRACONTROL V3.4 ............................................................................................................................15 3.3.1 Scada Server – Datasets and Dataitems...............................................................................................15 3.3.1.1 3.3.1.2
3.3.2 3.3.3
Scada server – Electric view.................................................................................................................18 E-terraBrowser.....................................................................................................................................19
3.3.3.1 3.3.3.2 3.3.3.3
3.3.4
Description for each datasets:.......................................................................................................................16 Description for each data items: ...................................................................................................................17
Analog Measurement I .................................................................................................................................19 Circuit Breaker POS.....................................................................................................................................19 Circuit Breaker Control (Open/Close)..........................................................................................................20
C264 configuration with PACiS SCE V4.33 .........................................................................................21
AREVA PACIS E-terraControl V3.4 & PACIS V4.2_A Installation & Configuration Guide - Issue A – 17/11/06
Identification Number: 2059660 Page: 4 / 21
CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
FIGURES Figure 1 : Installation SISCO MMS driver software................................................................ 9 Figure 2 : General architecture .............................................................................................11 Figure 3 : IEC61850 Configuration Server(s) tab ..................................................................12 Figure 4 : IEC61850 Configuration Model Download tab ......................................................13 Figure 5 : IEC61850 Configuration Settings..........................................................................13 Figure 6 : IEC 61850 Client ..................................................................................................14 Figure 7 : SCADA Datasets C264 ........................................................................................16 Figure 8 : Scada Database IEC61850ClientDS dataset........................................................16 Figure 9 : Scada Database Measurements...........................................................................17 Figure 10 : Scada Database Double Point Status.................................................................17 Figure 11 : Scada Database Single Point Status ..................................................................17 Figure 12: Scada Database Point control .............................................................................17 Figure 13 : Scada Electric view ............................................................................................18 Figure 14 : Webfgviewer Analog measurement ....................................................................19 Figure 15 : Webfgviewer Circuit Breaker position .................................................................19 Figure 16 : Popup dialog Trip / Close ...................................................................................20 Figure 17 : Electrical topology from PACiS SCE...................................................................21 Figure 18 : Electrical topology from E-terraSCADA..............................................................21
AREVA PACIS E-terraControl V3.4 & PACIS V4.2_A Installation & Configuration Guide - Issue A – 17/11/06
Identification Number: 2059660 Page: 5 / 21
CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
1. INTRODUCTION
1.1 DOCUMENT OBJECTIVE This document specifies the installations and configurations required allowing correct link between a C264 and E-terraControl system. The scope of this integration guide is to provide guidance to projects on approaches to integrating E-terraControl V3.4 and PACiS system V4.2.1.
1.2 Who Should Use This Document The audience for this document is as follows: • Systems integrators/engineers who are responsible for installing and configuring E-terraControl system with a C264 computer.
1.3 Operating System Support E-terraControl is certified on Windows Server 2003 and supported on Windows XP. • The Windows XP platforms had Service Pack 1 and Service Pack 2 applied, generally with the latest Microsoft critical updates.
1.4 REFERENCE DOCUMENTS •
Display Builder 5.5 Beta Release Notes.
•
E-terraControl 3.4 Beta Release Notes.
•
PACiS_Release Note_V4.2 Issue B.doc
AREVA PACIS E-terraControl V3.4 & PACIS V4.2_A Installation & Configuration Guide - Issue A – 17/11/06
Identification Number: 2059660 Page: 6 / 21
CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
1.5 ABBREVIATIONS BI CRA CT/VT DB DE DP FR FSS GPS IED I/O LBUS OI OWS PC RCP SBO SCE SMT SP TBC TI TPI XML SCADA
: Bus Interface : Change Request Analysis : Current Transformer/Voltage Transformer : Database : Direct Execute : Double Point : Fault Report : Force Suppress Substitute : Global positioning System : Intelligent Electronic Device : Input/output : Legacy Bus : Operator Interface : Operator WorkStation : Personal Computer : Remote Control Point : Select Before Operate : System Configuration Editor : System Management Tool : Single Point : To Be Completed : Telecontrol interface : Tap Position Indication : Extensible Markup Language : Supervisory Control and Data Acquisition
1.6 Compatibility
EterraControl V3.4
CMT V4.33A – E12
SMT J.01.04
AREVA PACIS E-terraControl V3.4 & PACIS V4.2_A Installation & Configuration Guide - Issue A – 17/11/06
PACIS V4.2.1 SCE Agency 4.37.F V3.22A
OI G.00.30
SCADA 2000 M4-RC37
Identification Number: 2059660 Page: 7 / 21
CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
2. INSTALLATION
2.1 E-terraControl v3.4 E-terrabrowser should be installed prior to E-terracontrol in order to guarantee that the shortcuts are properly created. If there is a problem with WebFG Viewer shortcut -- please run "Create WebFG Viewer Shortcut" from the 'E-terraControl\samples\Fix WebFG' start menu. If there is a problem with WebFG Viewer configuration -- please run "Fix WebFG Viewer Configuration" from the ‘E_terracontrol\samples\Fix WebFG' start menu.
2.2 PACiS Communications Agency V3.22a Kit packaged with E-terracontrol v3.4, in the “\areva\e_terracontrol\bin” directory corresponds to PACiS Communications Agency V3.18. Do not install this version. Agency V3.22a has to be installed. The IEC61850 Communications Agency is used by the IEC61850Config and IEC61850Client applications. This section describes installation and configuration of the Communications Agency and MMS driver infrastructure. 2.2.1 Installing the communications Agency The Communications Agency may need to be installed separately. The beta installation kit provides the communications agency installation kit within the SMP\bin directory. -
Run Agency_3.22a.exe – this will install the IEC61850 Communications Agency software in a folder named PACiS. Install it in disk:\areva\pacis folder using the same disk as the e-terracontrol and follow the instructions, accepting the default values.
2.2.2 Installing SISCO MMS driver software The IEC61850 Communications Agency application requires installation of a SISCO provided OSI device driver. AREVA PACIS E-terraControl V3.4 & PACIS V4.2_A Installation & Configuration Guide - Issue A – 17/11/06
Identification Number: 2059660 Page: 8 / 21
Follow the following steps to install the OSI LLC Protocol Driver :
CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
1. Select Start → Settings → Control Panel → Network and Dial-up Connection, then double click the Local Area Connection; click the Properties button, then the Install button. Select the network component type of Protocol and click the Add button. 3. From the Select Network Protocol Dialog Box, click the Have Disk... button. 4. From the Insert Disk Dialog Box, select the location of the “osillc.inf” file and click on OK to accept the path. The “.inf” file was installed with the agency in the following location [installation folder]\UCA2Agency\osillc\win2000 (or \winxp). 5. From the Select Network Protocol Dialog Box, click on OK. Click the Close button and restart your computer.
Figure 1 : Installation SISCO MMS driver software
AREVA PACIS E-terraControl V3.4 & PACIS V4.2_A Installation & Configuration Guide - Issue A – 17/11/06
Identification Number: 2059660 Page: 9 / 21
2.2.3 IEC61850 Client needs Anonymous RPCs with Service Pack 2
CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
After installing Windows XP Service Pack 2, a previously working IEC61850Client may not be able to form a connection to the IEC61850 Communications Agency. In this case, the IEC61850Client.log file will report that the Open Session call failed. This failure is because, by default, XP SP2 restricts the use of Remote Procedure Calls (RPCs). You can force RPC to exhibit the same behaviour as earlier versions of Windows by setting the registry key to RPC_RESTRICT_REMOTE_CLIENT_NONE (0). HKEY_LOCAL_MACHINE\SOFTWARE\Policies\Microsoft\WindowsNT\RPC\Restric tRemoteClients Value Set to 0
AREVA PACIS E-terraControl V3.4 & PACIS V4.2_A Installation & Configuration Guide - Issue A – 17/11/06
Identification Number: 2059660 Page: 10 / 21
CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
3. CONFIGURATION
3.1 Purpose • IEC61850 Configuration • IEC61850 Client • E-terraControl database SCADA • E-terraControl Webfg Viewer
OI E-terraControl
IEC61850 Agency
export SCE conf
C264_1
PACiS SCE
Figure 2 : General architecture
3.2 IEC 61850 3.2.1 Agency application The IEC61850Client applications will automatically start and stop the Agency application as needed. When running, the Agency application will place a small icon on the lower right of the machine's console. Double clicking on this icon will cause the agency log to be displayed. A hard copy of the agency log is also created in the directory where the agency executable resides (drive:\areva\pacis\UCA2agency\agency.log).
AREVA PACIS E-terraControl V3.4 & PACIS V4.2_A Installation & Configuration Guide - Issue A – 17/11/06
Identification Number: 2059660 Page: 11 / 21
3.2.2 IEC 61850 Configuration
CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
Before using IEC61850Client to communicate with a new device, the device's model must be obtained using the IEC61850Config application. •
IEC61850 Server(s) tab
All server connected to the IEC61850 Client must be define in the IEC61850 Server tab. For each server you must define the name and the IP Address of the server. All information entered are automatically updated in the lean.cfg and agency.cfg file. Server name is equal to the ARName define in the IEC61850Device Data set in the configuration of scada device.
Figure 3 : IEC61850 Configuration Server(s) tab
•
Model Download tab
By default, the obtained XML file will go into a new IEC61850WORK sub-folder of the E-terracontrol installation location. The integrator will not be able to override this location if desired.
AREVA PACIS E-terraControl V3.4 & PACIS V4.2_A Installation & Configuration Guide - Issue A – 17/11/06
Identification Number: 2059660 Page: 12 / 21
CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
Figure 4 : IEC61850 Configuration Model Download tab
•
Settings
After the model is obtained, a batch file could be launch directly. The batch file path must be selected with the menu -> File -> Settings. The batch file can be found IEC61850Work folder.
Figure 5 : IEC61850 Configuration Settings
AREVA PACIS E-terraControl V3.4 & PACIS V4.2_A Installation & Configuration Guide - Issue A – 17/11/06
Identification Number: 2059660 Page: 13 / 21
3.2.3 IEC 61850 Client
CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
The E-terracontrol IEC61850 application provides E-terracontrol with an interface to IEC61850 compliant devices. The IEC61850 Client applications use the PACiS Agency application to communicate with the IEC61850 devices. The SCADA database objects that are required by the IEC61850 Client application include: •
A hierarchical collection of Data Sets that model the IEC61850 Client's communication subsystem and IEC61850 device model (from the IEC61850 Client itself to the IEC61850 bricks).
•
The measurement definitions and values associated to the Data Sets under the form of Data Item collections.
Figure 6 : IEC 61850 Client
On the left is a tree display of the IEC61850 devices modeled in the E-terracontrol SCADA Server (database). It displays the remote device and the bricks modeled under it. On the right are details of any item selected in the tree. Current data value, quality, and timestamps are displayed in the details.
AREVA PACIS E-terraControl V3.4 & PACIS V4.2_A Installation & Configuration Guide - Issue A – 17/11/06
Identification Number: 2059660 Page: 14 / 21
3.3 E-terraControl V3.4
CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
3.3.1 Scada Server – Datasets and Dataitems SCADA datasets will be modeled in the SCADA database to define the following information to SCADA and the IEC61850Client application. •
IEC61850 client application information
•
IEC61850 device information (name and MMS ARName)
•
IEC61850 device logical devices and bricks to map into SCADA
In addition, a SCADA data source for the IEC61850Client application (type: device) needs to be modeled. The SCADA data source will reference a Dataset defining the IEC61850Client application. This is similar to CfeReader modeling.
The following SCADA dataset types need to be added to the E-terracontrol database to support this. •
IEC61850ClientDS: This SCADA dataset type will be assigned to the IEC61850Client Dataset.
•
IEC61850DeviceDS: This SCADA dataset type will be assigned to the IEC61850 device datasets.
•
IEC61850LogicalDeviceDS: This SCADA dataset type will be assigned to the IEC61850 logical device datasets.
•
IEC61850BrickDS: This SCADA dataset type will be assigned to the IEC61850 brick datasets.
•
IEC61850ControlDS: This SCADA dataset type will be assigned to the IEC61850 brick control datasets. This is used to model setpoints, Raise/Lower and control data items.
AREVA PACIS E-terraControl V3.4 & PACIS V4.2_A Installation & Configuration Guide - Issue A – 17/11/06
Identification Number: 2059660 Page: 15 / 21
3.3.1.1 Description for each datasets:
CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
IEC61850ClientDS – IEC61850ClientDS AgencyHeartBeat = 3000 NumMissedHeartbeats = 3 HeartbeatMonitor_Freq = 5000 ScanRate=5
C264 – IEC61850DeviceDS ARName = C264
CONTROL – IEC61850LogicalDeviceDS
YPTR1 – IEC61850BrickDS XCBR1/2 – IEC61850BrickDS XCBR1/2Ctrl – IEC61850ControlDS
Figure 7 : SCADA Datasets C264
Figure 8 : Scada Database IEC61850ClientDS dataset AREVA PACIS E-terraControl V3.4 & PACIS V4.2_A Installation & Configuration Guide - Issue A – 17/11/06
Identification Number: 2059660 Page: 16 / 21
3.3.1.2 Description for each data items:
CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
•
Measurements YPTR : MX$val_1$mag$f
Figure 9 : Scada Database Measurements •
Single and Double Point Status XCBR : ST$val_1$stVal
Figure 10 : Scada Database Double Point Status
Figure 11 : Scada Database Single Point Status •
Single Point Control XCBRCtrl: CO$val_1$open / CO$val_1$close
Figure 12: Scada Database Point control
AREVA PACIS E-terraControl V3.4 & PACIS V4.2_A Installation & Configuration Guide - Issue A – 17/11/06
Identification Number: 2059660 Page: 17 / 21
3.3.2 Scada server – Electric view SCADA equipments will be modeled in the SCADA database. Above, dataitems are assigned to equipments link and following equipments are assigned to Webfgviewer. CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
Stations – Stations Root Lattes – Substation CB1 – Circuit breaker CBPOS – Status
Webfgviewer link
CLOSE – TRIP
INC1 I1 – Analog
Figure 13 : Scada Electric view Webfgviewer link
AREVA PACIS E-terraControl V3.4 & PACIS V4.2_A Installation & Configuration Guide - Issue A – 17/11/06
Identification Number: 2059660 Page: 18 / 21
3.3.3 E-terraBrowser
CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
3.3.3.1 Analog Measurement I The picture below shows the partial composite key definition needed to complete the binding of the picture representing a measurement I2.
Figure 14 : Webfgviewer Analog measurement 3.3.3.2 Circuit Breaker POS The picture below shows the partial composite key definition needed to complete the binding of the picture representing a breaker with two switches.
Figure 15 : Webfgviewer Circuit Breaker position AREVA PACIS E-terraControl V3.4 & PACIS V4.2_A Installation & Configuration Guide - Issue A – 17/11/06
Identification Number: 2059660 Page: 19 / 21
3.3.3.3 Circuit Breaker Control (Open/Close)
CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
E-terrabrowser allows a tool tip to be associated with any visible object on a display. The picture below shows the popup dialog witch allow sending a command to the circuit breaker. Trip (binding)
Command : MAIL/USER=control_%disapp%_%disfam% TRIP
Close (binding)
Figure 16 : Popup dialog Trip / Close
Command : MAIL/USER=control_%disapp%_%disfam% CLOSE
AREVA PACIS E-terraControl V3.4 & PACIS V4.2_A Installation & Configuration Guide - Issue A – 17/11/06
Identification Number: 2059660 Page: 20 / 21
3.3.4 C264 configuration with PACiS SCE V4.33
CONFIDENTIAL. All rights reserved. AREVA. Passing on and copying of this document, use and communication of its contents are not permitted without prior written authorization.
The example below shows the comparative electrical topology between PACiS SCE and E-terraSCADA.
Figure 17 : Electrical topology from PACiS SCE
AREVA PACIS E-terraControl V3.4 & PACIS V4.2_A Installation & Configuration Guide - Issue A – 17/11/06
Figure 18 : Electrical topology from EterraSCADA
Identification Number: 2059660 Page: 21 / 21