Ducted Split Unit

May 15, 2018 | Author: Eric Chin | Category: Air Conditioning, Mechanical Fan, Insulator (Electricity), Epoxy, Gas Compressor
Share Embed Donate


Short Description

Download Ducted Split Unit...

Description

INDOOR UNIT (SINGLE SKIN) INDOOR UNIT (DOUBLE SKIN)* OUTDOOR UNIT Btu/h W INPUT POWER W RUNNING CURRENT - 1Ø [3Ø]  A POWER SOURCE V/Ph/Hz REFRIGERANT TYPE / CONTROL l/s / CFM INDOOR AIR FLOW Pa(in.wg.) INDOOR FAN ESP (H/M/L) SOUNDPRESSURELEVEL(H/M/L) dBA UNIT DIMENSION, INDOOR UNIT mm HxWxD OUTDOOR UNIT mm INDOOR UNIT UNIT WEIGHT kg OUTDOOR UNIT

YSB 40B -

MODEL

YSL 35D 35,000 10,258 3,493 16.42 220-240/1/50

TOTAL COOLING CAPACITY

LIQUID GAS

COPPER PIPE SIZE

LIQUID GAS

LIQUID GAS

COPPER PIPE SIZE

50 95

LIQUID GAS

COPPER PIPE SIZE

mm/in mm/in

61 572 x 1,502 x 761

104 9.5 / 3/8

55 104

85 108 12.7 / ½

19.1 / 3/4

YSB 80B YDSB 80B MYSS 72C* 70,000 20,516 7,109 [13.58]

MYSS 80C 80,000 23,447 8,083 [16.07]

1,180 / 2,500 100 / 0.4 56 572 x 1,502 x 761 946 x 1,300 x 500 92 145 12.7 / ½ 25.4 / 1

YSB 200B2 YDSB 200B2 MYS S10 0B x 2 200,000 58,617 20,710 [38.7]

3,021 / 6,400 158 / 0.6 61 945 x 1,894 x 980 (946 x 939 x 1,116) x 2 220 164 x 2

mm/in mm/in

INDOOR UNIT (SINGLE SKIN) MODEL INDOOR UNIT (DOUBLE SKIN)* OUTDOOR UNIT Btu/h TOTAL COOLING CAPACITY W INPUT POWER W RUNNING CURRENT - 1Ø [3Ø]  A POWER SOURCE V/Ph/Hz REFRIGERANT TYPE / CONTROL INDOOR AIR FLOW l/s / CFM INDOOR FAN ESP (H/M/L) Pa(in.wg.) SOUNDPRESSURELEVEL(H/M/L) dBA UNIT DIMENSION, INDOOR UNIT mm HxWxD OUTDOOR UNIT mm INDOOR UNIT UNIT WEIGHT kg OUTDOOR UNIT

944 / 2,000 100 / 0.4

53 852 x 1,030 x 400

mm/in mm/in

INDOOR UNIT (SINGLE SKIN) MODEL INDOOR UNIT (DOUBLE SKIN)* OUTDOOR UNIT Btu/h TOTAL COOLING CAPACITY W INPUT POWER W RUNNING CURRENT - 1Ø [3Ø]  A POWER SOURCE V/Ph/Hz REFRIGERANT TYPE / CONTROL INDOOR AIR FLOW l/s / CFM INDOOR FAN ESP (H/M/L) Pa(in.wg.) SOUNDPRESSURELEVEL(H/M/L) dBA UNIT DIMENSION, INDOOR UNIT mm HxWxD OUTDOOR UNIT mm INDOOR UNIT UNIT WEIGHT kg OUTDOOR UNIT

755 / 1,600

572 x 892 x 761

MODEL

COPPER PIPE SIZE

YSB 60B YSL 61D 61,000 17,878 6,672 [10.46]

INDOOR CAP. TUBE 590 / 1,250 100 / 0.4 53

mm/in mm/in

INDOOR UNIT (SINGLE SKIN) INDOOR UNIT (DOUBLE SKIN)* OUTDOOR UNIT Btu/h TOTAL COOLING CAPACITY W INPUT POWER W RUNNING CURRENT - 1Ø [3Ø]  A POWER SOURCE V/Ph/Hz REFRIGERANT TYPE / CONTROL INDOOR AIR FLOW l/s / CFM INDOOR FAN ESP (H/M/L) Pa(in.wg.) SOUNDPRESSURELEVEL(H/M/L) dBA UNIT DIMENSION, INDOOR UNIT mm HxWxD OUTDOOR UNIT mm INDOOR UNIT UNIT WEIGHT kg OUTDOOR UNIT

YSB 50B YSL 50D 50,000 14,654 5,457 [9.08] 380-415/3/50

YSL 40D 40,000 11,723 4,833 [7.27]

28.6 / 11 /8

YSB 400B4 YDSB 400B4 MYSS100B x 4 400,000 117,233 40,795 [76.1]

5,664 / 12,000 200 / 0.8 66 1,546 x 2,274 x 1,466 (946 x 939 x 1,116) x 4 513 164 x 4 28.6 / 1 1/8

YSB 100B YDSB 100B MYSS 100B 100,000 29,308 10,790 [19.38] 380-415/3/50 INDOOR TXV 1,510 / 3,200 100 / 0.4 57

102 164

YSB 125B YDSB 125B MYSS 125B 125,000 36,635 11,910 [21.57]

1,982 / 4,200 149 / 0.6 58 8 85 x 1 ,6 40 x1 ,0 40 946 x 939 x 1,116 176 169 15.9 / 5/8

28.6 / 1 1/8

YSB 250B2 YDSB 250B2 MY SS 1 25 Bx 2 250,000 73,271 24,510 [44.30]

YSB 350B3 YDSB 350B3 MYSS 100B

• Penang Tel: 04-331 1670 • Perak Tel: 05-548 2307 • Sarawak Tel: 082-333 299

Service Centre:

• Alor Setar

MYSS 125Bx2 350,000 102,579 36,280 [76.57]

4,956 / 10,500 200 / 0.8 66 1,546 x 2,122 x 1,199 946 x 939 x 1,116 (946 x 939 x 1,116) x 2 440 164 169 x 2 28.6 / 1 1/8

34.9 / 1 3/8

YSB 500B4 YSB 500B4 YSB 600B4 YSB 750B5 YDSB 500B4 YDSB 500B4 M YS S1 00 Bx 2 M YS S1 25 Bx 2 MYSS 125B x 4 MYSS 150C x 4 MYSS 150C x 5 450,000 500,000 600,000 750,000 131,887 146,542 175,850 219,812 46,855 49,715 72,516 89,420 [100.42] [89.34] [136.68] [169.10] 380-415/3/50 INDOOR TXV 7,080 / 15,000 7,080 / 15,000 8,496 / 18,000 10,619 / 22,500 250 / 1.0 250 / 1.0 300 / 1.2 350 / 1.4 68 70 71 1,546 x 2,274 x 1,466 1,978 x 2,274 x 1,905 2,257 x 2,274 x 1,905 ( 94 6 x 93 9x 1, 11 6) 6) x2 ( 94 6x 93 9x 1, 11 6) x2 ( 94 6x 93 9 x 1, 11 6) x4 (1,041 x 939 x 1,116) x 4 ( 1, 04 1x 93 9x 1, 11 6) x5 564 991 1,051 164 x 2 169 x 2 169 x 4 227 x 4 227 x 5 15.9 / 5/8 28.6 / 11 /8 34.9 / 1 1/8 34.9 / 1 3/8

(109719-M)

Head Office: Tel: 03-7718 8388 Fax: 03-7727 4371 Email: [email protected], [email protected] Branches:

2,171 / 4,600 149 / 0.6 59 8 85 x 1 ,6 40 x1 ,0 40 1,041 x 939 x 1,116 189 227 34.9 / 1 3/8

YSB 300B2 YDSB 300B2 MYSS 150C x 2 300,000 87,925 34,688 [66.50] 380-415/3/50 INDOOR TXV 3,776 / 8,000 4,248 / 9,000 200 / 0.8 200 / 0.8 63 66 1,291 x 1,866 x 1,199 (946 x 939 x 1,116) x 2 (1,041 x 939 x 1,116) x 2 343 343 169 x 2 227 x 2 15.9 / 5 /8 34.9 / 1 3 /8

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ARI 210/240. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW: COOLING - 26.7°C DB / 19.4°C WB INDOOR AND 35°C DB / 23.9°C WB OUTDOOR 4) EER CALCULATION IS BASED ON EFFECTIVE POWER INPUT AS PER ARI 210/240. 5) * FOR PROJECT BASIS 6) INDOOR UNIT DIMENSION, INDOOR WEIGHT, INDOOR AIR FLOW AND INDOOR FAN ESP IS FOR SINGLE SKIN ONLY. 7) ESP ON TABLE ABOVE IS WITHOUT THE FILTER.

Group Associated (C&L) Sdn Bhd

YSB 150B1 YDSB 150B1 MYSS 150C 150,000 43,962 16,211 [31.77]

• Johor Tel: 07-557 7788 • Pahang Tel: 09-567 6778 • Melaka Tel: 06-288 1133 • Sabah Tel: 088-722 194 • Negeri Sembilan Tel: 06-768 8969

• Kota Bharu Authorized dealer:

HighDucted Static Split

The Trusted Quality And Name In Air-Conditioning

This unprecedented innovation is brought to you by YORK - the trusted name in air-conditioning for quality and reliable after-sales-service. With a nationwide service network. YORK is ever ready to take you to a new dimension in cooling comfort. 100% coil leak test by helium testing method and every components being used in YORK unit are tested, at R&D test lab, which is registered under ISO standard and recognised by Sirim.

YSB 750B5

YSB 600B4

Copper tubes were tested at burst pressure, where it is at least 3 times the refrigerant operating pressure. Every unit receives a 100% unit run test before leaving the production line in the facrtory, which is registered under ISO standard and recognised by Sirim.

YSB 400B4 /500B4

YSB 350B3

Modular Combination

Insulation

With only 7 different capacities outdoors, YORK ducted split product range is ranking up to an individual indoor unit at 750kBtu/h.

Fire-resistant Polyethylene is used at every possible condensate panel to prevent all forms of water or moisture penetration. Polyethlene, which is also a type a Closed Cell Foam Insulation (CCF) has offered the following advantages: • Durable external surface that resists dirt tough and resilient. • Higher degree of puncture resistance when compared to fiberglass. • Easily cleaned surface (if necessary) to further resist microbial growth.

Cabinet Construction Both indoor and outdoor are coated with weatherproofed electro galvanized mild steel casing, with an epoxy is coated with an epoxy polyester powder costing for severe external conditions. Service panel is available at the convenience side for both indoor and outdoor.

Indoor Air Throw Direction YSB 250B2/ 300B2/ 300B3

With the choices of vertical and horizontal air throw make it versatile to various architectual design.

YSB 200B2

Changeable Drive Package Wide Product Range

YSB 125B/ 150B

YORK ducted split is offering very wide range of product lineup which is applicable from residential, to light commercial or even commercial use. YSB 60B/ 80B/ 100B

Non-standard external static pressure & airflow requirement can be sized by changing the factory fitted drive package. (for belt drive model only)

Easy To Reach Access Valve Discharge line and suction line access valve is accessible without opening the unit casing.

Components • Compressor: Each high efficiency scroll type compressor is hermetically sealed, quiet running and supported on rubber mounts to minimize vibration. • Indoor Fan: A dynamically balanced forward curved fan with a field changeable pulley package, in order to match the designed supply air requirements.

Safety Fearures • High pressure and low pressure protection • Phase sequencer is used to detect for any wrong phase and phase loss during installation and operation. • Compressor & motor current overload protection. Minimum compressor's running time to ensure oil return.

View more...