Drive Test Problems

August 12, 2017 | Author: Abdullah M. Saleh | Category: Broadcasting, Electronic Engineering, Wireless, Telecommunications Engineering, Electrical Engineering
Share Embed Donate


Short Description

Drive Test Problems...

Description

2010

Mohaned Yousef Ismail Yousef Telecommunication Engineer

Drive Test problems (2G,3G)

Mohaned Yousef Ismail Yousef E-mail: [email protected] Mobile : +2 0104585755

Mohaned Yousef Ismail Yousef Telecom engineer Problem No.1

Different LAC [location area code] (2G). How I can find it : By looking at [GSM current channel] window , I will see that my site have different LAC from its neighbors. How it can be solved : Tell the operator about that problem and they will change it to the right one.

Problem No.2

Shifted azimuth (2G,3G) How I can find it : from the coverage area of the site I find that the azimuth of that site is not logical. How it can be solved : Tell the Technician to check the azimuth of the sectors to be similar to the planned azimuth.

2

Drive Test problems (2G & 3G)

Mohaned Yousef Ismail Yousef Telecom engineer Problem No.3

Handover failure (2G) How I can find it : it happens when a sector in a site is not defined for the other sites around it. How it can be solved : report that to the operator and they will define the sectors to each other and solve the problem.

Problem No.4

Overshooting How I can find it : I will find in the coverage region of a site which should be serve it with good level ,that there are another site server in it with good level and it may cause interference. How it can be solved : down tilt the site which overshoot in that region to avoid interference.

3

Drive Test problems (2G & 3G)

Mohaned Yousef Ismail Yousef Telecom engineer Problem No.5

Gaps (2G) How I can find it : When I test the coverage on a main road sometimes I find a gap between 2 sites because there are far away from each other or one of them is down tilt. How it can be solved : by up tilting one of them to serve this gap.

Problem No.6

Hopping channels problems (2G) How I can find it : In 2G, sometimes the hopping channels technique doesn’t work and I find that from the [hopping channel] window. How it can be solved : Call the integrator to fix this problem.

4

Drive Test problems (2G & 3G)

Mohaned Yousef Ismail Yousef Telecom engineer Problem No.7

Site down (2G,3G) How I can find it : when i call the front office to activate a site it may be down for 2 reasons , down for transmission [E1 down] or power reason. How it can be solved : Report that to the operator to solve the problem by check E1 connection or power of the site.

Problem No.8

Connectivity problem (2G,3G) How I can find it : connectivity problems cause bad level , bad quality ,bad coverage area and blocked calls. How it can be solved: tell technician to check feeders ,connectors and jumbers.

5

Drive Test problems (2G & 3G)

Mohaned Yousef Ismail Yousef Telecom engineer Problem No.9

Wrong configuration (2G) How I can find it : I notice that from the [hopping channels] window that the real configuration different from the planed configuration. How it can be solved : Tell the operator to modify the TCHs to be as the planned.

Problem No.10

Ping pong handover (2G) How I can find it : it happens when there are a small region all sites serve it with the same level so the MS will handle between them quickly and this may cause dropped calls. How it can be solved : Tell the operator to solve this problem by down tilt some sites and reduce other sites .

6

Drive Test problems (2G & 3G)

Mohaned Yousef Ismail Yousef Telecom engineer Problem No.11

Blocked calls (2G,3G) How I can find it : It happens due to RACCH error [due to high traffic] or connectivity problem, How it can be solved : Tell technical to check connectivity.

Problem No.12

No RRC Connection setup (3G) How I can find it : in this case, I can’t access on that site due to hardware problem. How it can be solved: Tell technical team to solve that problem.

7

Drive Test problems (2G & 3G)

Mohaned Yousef Ismail Yousef Telecom engineer Problem No.13

Cross sector [2G, 3G] . How I can find it : two different sectors in the same site serve in the each other area. It happens when the 2 feeders of the TRUs of 2 antennas inversed with each other. How it can be solved : Tell the technical team to inverse the input feeders of these antennas to solve this problem.

8

Drive Test problems (2G & 3G)

Mohaned Yousef Ismail Yousef Telecom engineer Problem No.14

Cross feeder [2G] How I can find it : As an example in site with 2 sectors, I will find that sector A serve in its region and in Sector B region too and the RxLevel will be almost the same in the to regions. It happens when one feeder is inversed in the 2 antennas with each other. How it can be solved : Tell the technical team to inverse the input feeder of these antennas to solve this problem and inform them that there are a cross feeder problem.

9

Drive Test problems (2G & 3G)

Mohaned Yousef Ismail Yousef Telecom engineer Problem No.15

VSWR [Voltage standard wave ratio] [2G] How I can find it : Under the site we must see the levels of all sectors is the best, when I find Rx-Level of one of the sectors is bad so it will be VSWR problem [connectivity problem]. How it can be solved : Tell the technical team that there are VSWR , please check connectivity

10

Drive Test problems (2G & 3G)

Mohaned Yousef Ismail Yousef Telecom engineer Problem No.16

Faulty DTRU [2G] How I can find it : In the main beam of a sector [In dedicated mode] the TCH channels must be in good levels.. when a level of a TCH is bad , so it’s a faulty DTRU. How it can be solved: Replace the DTRU that have a problem by new one.

11

Drive Test problems (2G & 3G)

Mohaned Yousef Ismail Yousef Telecom engineer Problem No.17

Disconnected DTRU [2G] How I can find it : Before doing any acceptance for any 2G site . I must know the configuration of that site .As an example if the configuration of Cell E is 4 TCH 1800 Band and I found it 3 TCHs and I check with integrator and he tell me that there is not any problem in the assigned frequencies so there is a disconnected DTRU. How it can be solved : Tell the technician that there is a disconnected DTRU on Cell E and he will solve the problem.

12

Drive Test problems (2G & 3G)

Mohaned Yousef Ismail Yousef Telecom engineer

Problem No.18 Co-channel interference How I can find it : By looking at [hopping channel] window I can fine the C/I [carrier over interference ratio] is bad . The Co-channel interference happens when there are two frequencies [the same] interfere with each other. How it can be solved : Tell the operator about that frequency and the will solve the problem. Problem No.19 Adjacent interference How I can find it : By looking at [hopping channel] window I can fine the C/I [carrier over interference ratio] is bad . The Adjacent interference happens when there are two frequencies [closed together] interfere with each other. How it can be solved : Tell the operator about that 2 frequencies and the will solve the problem.

13

Drive Test problems (2G & 3G)

Mohaned Yousef Ismail Yousef Telecom engineer

Problem No.20

Handover intracell failure (2G) How I can find it : in TEMS this alert will appear in Events window How it can be solved : there is no synchronization between 900 TCHs and 1800 TCHs cabins ,So the technical will solve that problem by make synchronization between them by help from the integration office.

14

Drive Test problems (2G & 3G)

Mohaned Yousef Ismail Yousef Telecom engineer

Problem No.21

Wrong position ( Wrong Lat & Long) How I can find it : go to the given co-ordinates and I didn’t find the site . [Survey team mistake] How it can be solved : search for the site in the field around the wrong co-ordinates region .

15

Drive Test problems (2G & 3G)

Mohaned Yousef Ismail Yousef Telecom engineer

Problem No.22

Missing neighbor relations. [3G] How I can find it : in TEMS this alert will appear in Events window and it happens when 2 sites neighbors and didn’t defined to each other. How it can be solved : Tell the operator by the missing neighbors data and the problem will be solved

16

Drive Test problems (2G & 3G)

Mohaned Yousef Ismail Yousef Telecom engineer

Problem No.23

HSDPA failed. [3G] How I can find it : the average speed of HSDPA through put speed didn’t reach for the acceptable range. How it can be solved : it is a problem in hardware or in integration .

17

Drive Test problems (2G & 3G)

Mohaned Yousef Ismail Yousef Telecom engineer

Problem No.24

Shifted azimuth (2G,3G) How I can find it : It appears from the illogical coverage area of the sector which have shifted azimuth. How it can be solved : I ask for the real azimuth and modify it.

18

Drive Test problems (2G & 3G)

Mohaned Yousef Ismail Yousef Telecom engineer

Problem No.25

IRAT failed ( 3G-2G) How I can find it : in dedicated mode , when the call have very bad RSCP and EcNo in 3G, it must go to 2G . If it wasn’t happened so IRAT failed. How it can be solved : The integration office will solve this problem.

19

Drive Test problems (2G & 3G)

Mohaned Yousef Ismail Yousef Telecom engineer

Problem No.26

Reselection Failed(2G-3G) How I can find it : In idle mode, the priority for 3G . if we are on 2G in idle mode and it does not go to 3G so reselection failed. How it can be solved : The integration office will solve this problem.

20

Drive Test problems (2G & 3G)

Mohaned Yousef Ismail Yousef Telecom engineer

Problem No.27

Dropped Calls . How I can find it : it happens due to bad level and quality . How it can be solved : Report the operator about this problem after analyzing it ,depending on its case.

Problem No.28

Bad coverage area due to wrong tilts How I can find it : in the field I will find poor coverage of a sector so there will be a tilts problems [ down tilt] How it can be solved : Tell the Technician to uptilt that sector to get the required coverage area.

Problem No.29

PS [packet switching] doesn’t initiate. How I can find it : when I test the PS browsing of any 2G site , it doesn’t initiate according to hardware problem or integration problem. How it can be solved : Check with integration and if there are a problem there so it will be hardware problem solved by technical team.

21

Drive Test problems (2G & 3G)

View more...

Comments

Copyright ©2017 KUPDF Inc.
SUPPORT KUPDF