RecoverPoint Version 4.4

boxmgmt Guide 302-002-829 REV 01

Copyright © 2016 EMC Corporation. All rights reserved. Published in the USA. Published April, 2016 EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. The information in this publication is provided as is. EMC Corporation makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. EMC², EMC, and the EMC logo are registered trademarks or trademarks of EMC Corporation in the United States and other countries. All other trademarks used herein are the property of their respective owners. For the most up-to-date regulatory document for your product line, go to EMC Online Support (https://support.emc.com). EMC Corporation Hopkinton, Massachusetts 01748-9103 1-508-435-1000 In North America 1-866-464-7381 www.EMC.com

2

RecoverPoint 4.4 boxmgmt Guide

CONTENTS

Tables

5

Chapter 1

Installation Manager (boxmgmt)

7

Chapter 2

Installation

9

Chapter 3

Setup

11

Modify settings............................................................................................. 12 Enter cluster details......................................................................... 12 Number of virtual ports per port....................................................... 12 WWN node/port pair addresses....................................................... 12 Enable/disable initiator-only mode.................................................. 12 Number of VMware ITLs needed....................................................... 12 MTU configuration............................................................................12 Configure repository volume .........................................................................13 Get remote settings....................................................................................... 13 Retrieve previous settings............................................................................. 13 Apply settings............................................................................................... 13 View settings.................................................................................................13 Reset settings changes..................................................................................13 Advanced options......................................................................................... 13 Clear reservations............................................................................ 13 Unregister reservations.................................................................... 13 Reboot Regulation............................................................................14 Security options............................................................................... 14 Appliance Config Params................................................................. 15 Run Scripts...................................................................................... 15 Remove host from SSH known host file............................................ 15 Storage device customizations.........................................................15 Register with ESRS gateway..............................................................16 Set time via NTP............................................................................... 16 Enable/Disable logging of incoming FC headers............................... 16 Clear reservations............................................................................ 16 Unregister reservations.................................................................... 16 BMC support.................................................................................... 16 Console configuration .................................................................................. 17

Chapter 4

Diagnostics

19

IP diagnostics................................................................................................20 Cluster connectivity tests................................................................. 20 View IP details................................................................................. 20 View routing table............................................................................ 20 Test throughput............................................................................... 20 Ports diagnostics............................................................................. 20 System connectivity......................................................................... 20 SAN diagnostic..............................................................................................21 Run SAN diagnostics........................................................................ 21 RecoverPoint 4.4 boxmgmt Guide

3

CONTENTS

View RPA ports................................................................................. 21 View target LUNs.............................................................................. 21 Perform I/O to a LUN........................................................................ 21 Synchronization diagnostics......................................................................... 22 Collect system information............................................................................ 22 Run internal command..................................................................... 23

Chapter 5

Cluster operations

25

Detach/Attach RPA from/to cluster................................................................26 Prepare this cluster for connection to an existing cluster............................... 26 Connect a new cluster to this system.............................................................26 Remove a cluster from the system................................................................. 26 Configure connection types to the other clusters in the system......................26 Remove the link between two clusters...........................................................26

Chapter 6

Shutdown/Reboot operations

27

Reboot RPA................................................................................................... 28 Shutdown RPA...............................................................................................28

4

RecoverPoint 4.4 boxmgmt Guide

TABLES

1

BMC interface ports....................................................................................................... 16

RecoverPoint 4.4 boxmgmt Guide

5

TABLES

6

RecoverPoint 4.4 boxmgmt Guide

CHAPTER 1 Installation Manager (boxmgmt)

The Installation Manager, also known as “boxmgmt,” allows you to modify and manage existing RPA configurations and test and diagnose the settings and connectivity of RPAs before and after they are attached to RPA clusters. Accessing Installation Manger To access the Installation Manager, use an ssh client. Create an ssh session to the IP address of the RPA, user = boxmgmt. Using Installation Manager To select a menu option, enter the number of the desired selection. To accept the current value or the default if there is no current value, press Enter.

Installation Manager (boxmgmt)

7

Installation Manager (boxmgmt)

8

RecoverPoint 4.4 boxmgmt Guide

CHAPTER 2 Installation

Installation through the Installation Manager is intended for use in troubleshooting by authorized EMC personnel only. Only Deployment Manager is supported for RecoverPoint installations. For RecoverPoint with VNX or RecoverPoint with VNXe, using SE licenses, the RecoverPoint Customer Installation Kit is available on the EMC Online Support site (https://support.emc.com/).

Installation

9

Installation

10

RecoverPoint 4.4 boxmgmt Guide

CHAPTER 3 Setup

The Setup menu allows you to execute deployment activities independent of the various Deployment Manager wizards. l l l l l l l l l

Modify settings..................................................................................................... 12 Configure repository volume .................................................................................13 Get remote settings............................................................................................... 13 Retrieve previous settings..................................................................................... 13 Apply settings....................................................................................................... 13 View settings.........................................................................................................13 Reset settings changes..........................................................................................13 Advanced options................................................................................................. 13 Console configuration .......................................................................................... 17

Setup

11

Setup

Modify settings To change RPA setting, first detach the RPA from the RPA cluster. You must apply (or reapply) the modified configuration to each of the RPAs in the installation. If you have changed the cluster name or time zones, you must format (or reformat) the repository volume in both clusters. Then re-attach the RPA to the RPA cluster.

Enter cluster details The Configure ETH auto-negotiation option is used to adjust the Ethernet speed of the RPA’s WAN and LAN interfaces. Log in to each RPA to enable, disable, or change the auto-negotiation values. Valid values are 10 Mb Full duplex, 100 Mb Full duplex, or 1 Gb full duplex. To prevent communication problems between RPAs, ensure that all RPAs in all clusters are configured to the same setting. The values set for the RPAs and the values on the switches to which the RPAs are connected must also be identical. First change the LAN speed for all of the RPAs in the environment. Then change the LAN speed on the relevant ports on the switch. Configuring the value for an RPA’s LAN interface may disable the RecoverPoint session momentarily.

Number of virtual ports per port To associate an RPA Fibre Channel port with multiple storage groups simultaneously, use the Number of virtual ports per port option to specify the number of virtual ports (up to 16) per actual port for each RPA. Every switch port to which a RecoverPoint port is connected must be set to FL (Fibre loop or public loop) topology.

WWN node/port pair addresses Generally, you do not need to change the WWN node and port addresses. WWN node/ port pair addresses can also be changed through the Deployment Manager RPA Replacement wizard.

Enable/disable initiator-only mode The Enable/disable initiator-only mode option is used to designate some of the RPA ports as “initiator-only” (rather than “target or initiator”), which is required when working with certain types of storage.

Number of VMware ITLs needed To support replicating VMware data volumes with RecoverPoint (physical) using splitters running on virtual machines, you must set the option Number of VMware ITLs . This option must be set to the largest number of VMware virtual machines that will be running on any one ESX server in this cluster. Refer to the Replicating VMware with EMC RecoverPoint Technical Notes for details. If you set the number too low, you will not be able to replicate all the desired virtual machines. If you set it too high, you may trigger unnecessary system discovery, which may affect system performance.

MTU configuration The MTU configuration option is used to view or change the maximum transmission unit (MTU) packet size (in bytes) of an RPA’s LAN, WAN, and iSCSI interfaces. To prevent 12

RecoverPoint 4.4 boxmgmt Guide

Setup

communication problems, the MTU value must be the same on all RPAs in the environment. The default MTU value is set by the RPA operating system.

Configure repository volume Using this option is not supported.

Get remote settings To copy the settings of another RPA, follow the instructions on screen.

Retrieve previous settings After upgrading software, instead of entering all system parameters again, run Retrieve previous settings to restore all previous settings. Then, execute the following commands: Run SAN Diagnostics, Apply, and Attach. It is preferable to use Auto-Upgrade instead of this command.

Apply settings To set a machine's configuration, you must apply the settings that you type in or retrieved from an installed RPA.

View settings Displays cluster settings.

Reset settings changes To cancel any changes that you have made to settings, but which you have not yet applied.

Advanced options Clear reservations This command is useful if the reservation is preventing the RPAs from communicating with that volume. Once you select the command, the Installation Manager presents a list of all volumes available to the RPA. Select the volume from which you want to clear the reservation. The Installation Manager returns a notification stating whether the action has succeeded or failed.

Unregister reservations The Unregister reservations option is for use by EMC Customer Service.

Configure repository volume

13

Setup

When the storage array supports the SCSI-3, the RPA automatically registers with the storage array so that it can perform I/O operations. The RPA also unregisters automatically. In exceptional cases, it may be necessary to unregister manually. To unregister manually, select Unregister reservations. All LUNs that are accessible to the RPA are listed. Select the one you wish to unregister.

Reboot Regulation If Reboot Regulation is enabled, frequent RPA reboots or failures will cause the RPA automatically to detach from its cluster. l

Use the Set parameters command to configure the number of reboots and the time interval.

l

The default values are 6 reboots within 120 minutes. Use Restore default parameters command to reset the parameters to these default values.

After you have identified and corrected the problem, reactivate the RPA by re-attaching it to its RPA cluster.

Security options Change web server mode options https and http The RPA listens both on the HTTP port (port 80) and HTTPS port (port 443). https only The RPA listens only on the HTTPS port (port 443). The RPA will present a certificate when a connection is made. To enforce a consistent security policy requiring HTTPS, HTTPS only must be set on every RPA in the entire system. Change web server certificate To enforce a consistent security policy, Change web server certificate must be used to change to a non-default certificate on every RPA in the entire system. Follow directions on screen. If your certificate is not in Base64 format, you must use FTP. Enable/disable remote connection To enable or disable the use of secure shell (SSH) to connect to this RPA. Only affects the admin and boxmgmt users. To manage remote access of other users to the RPA, change their privileges. Log-on banner options Display log-on banner text The text appears before the user logs on. Enter log-on banner text Enter the text that will appear before the user logs on. Disable log-on banner text To remove the text displayed before the user logs on. Change appliance communication security level Relevant only on RPAs running RecoverPoint 4.1.1 or later. When the RPA is attached to a cluster, this command changes the MPI security level of the entire system. The following MPI security levels are available: 14

RecoverPoint 4.4 boxmgmt Guide

Setup

Accessible Communication between RPAs is not authenticated or encrypted. RPAs can communicate with each other only by adhering to the RecoverPoint proprietary protocol. Authenticated RPA clusters use certificates to authenticate each other before communicating. This option minimally impacts RPA performance. Authenticated and encrypted RPA clusters use certificates to authenticate each other before communicating. All communication between RPA clusters is also encrypted. This option moderately impacts RPA performance. This security level is FIPS compliant. When the WAN connection between clusters is down, changing the RPA communication security level of the cluster will only succeed when cluster isolation mode is enabled. When cluster isolation mode is enabled, changing the RPA communication security level will succeed only at the RPA cluster on which the command is run. The RPA communication security level at the other RPA clusters must be manually changed to match the local RPA cluster security level. View certificate Relevant only on RPAs running RecoverPoint 4.1.1 or later. Change cluster certificate Relevant only on RPAs running RecoverPoint 4.1.1 or later. To change the authentication certificate of the remote RPA clusters. Paste the new remote cluster certificate here. Enable/disable cluster isolation Relevant only on RPAs running RecoverPoint 4.1.1 or later. Enable cluster isolation mode when you need to regenerate a new certificate or change the RPA communication security level and the WAN connection between RPA clusters is down. After enabling cluster isolation, run the CLI command regenerate_encryption_keys. In boxmgmt, select View the certificate. Then log in to boxmgmt at the other cluster and select Change cluster certificate to paste the certificate from the other cluster. Then disable cluster isolation mode.

Appliance Config Params For use by authorized EMC personnel only.

Run Scripts To run a signed script provided by EMC Customer Service. Scripts run only for the designated customer in the designated time period. Paste the entire script exactly as received from EMC Customer Service.

Remove host from SSH known host file As shown

Storage device customizations For use by EMC Customer Service only.

Appliance Config Params

15

Setup

Register with ESRS gateway EMC Secure Remote Support (ESRS) allows EMC Customer Service representatives to securely connect to customer RPAs registered with the ESRS gateway, and to provide hands-on support, monitoring and auditing, in the following cases: l

Customers call EMC Customer Service and request to open a Service Request.

l

When a Service Request is automatically opened by the RecoverPoint system alerts mechanism.

How to enable ESRS server To enable ESRS support, register each RPA, in each RPA cluster, with the ESRS gateway as prompted. You will only need to re-register RPAs in the gateway in the following cases: l

An RPA box management IP address is modified.

l

The cluster management IP is modified.

l

An RPA is added or replaced.

This option is not enabled for EMC OEMs.

Set time via NTP Before selecting the Set time via NTP command, you must apply settings.

Enable/Disable logging of incoming FC headers To enable or disable Fibre Channel data tracking.

Clear reservations Do not use this command unless instructed to do so by authorized RecoverPoint Customer Service. This command is useful if the reservation is preventing the RPAs from communicating with that volume.

Unregister reservations The Unregister reservations command is for use by EMC Customer Service. When the storage array supports the SCSI-3, the RPA automatically unregisters reservations. In exceptional cases, it may be necessary to unregister manually.

BMC support BMC support is available for Gen5 and Gen6 RPAs. By default, BMC support is disabled. The Baseboard Management Controller (BMC) may be accessed through the following BMC interface ports: Table 1 BMC interface ports

RPA hardware BMC interface ports Gen5

WAN, LAN, Dedicated BMC port

Gen6

Dedicated BMC port, eth0 (WAN)

The BMC support command has the following options: 16

RecoverPoint 4.4 boxmgmt Guide

Setup

l

View BMC settings

l

Configure BMC

l

Enable/Disable BMC network access

Note

If the LAN or WAN port is shared by the RPA and the BMC server, network issues may affect BMC access.

Console configuration To configure the boxmgmt console.

Console configuration

17

Setup

18

RecoverPoint 4.4 boxmgmt Guide

CHAPTER 4 Diagnostics

The Diagnostic menu allows you to test the functionality and connectivity of your RPA configuration before and after attaching it to the RPA cluster. l l l l

IP diagnostics........................................................................................................20 SAN diagnostic......................................................................................................21 Synchronization diagnostics................................................................................. 22 Collect system information.................................................................................... 22

Diagnostics

19

Diagnostics

IP diagnostics Cluster connectivity tests The following connectivity tests are performed: l

Gateways - for a single vRPA only

l

Primary DNS server

l

Secondary DNS server

l

NTP server

l

Other host

View IP details As shown

View routing table As shown

Test throughput For a single cluster, the Test throughput option does not appear. The system uses iperf to test throughput to another RPA. Enable the iperf server before testing throughput. Disable the iperf server after testing throughput.

Ports diagnostics Procedure 1. Verify that none of the ports used by the RPAs are blocked (for instance, by a firewall). You must test each RPA individually by designating each RPA in turn to be the server. 2. Before selecting the server option, detach the RPA that you intend to designate as the server. 3. After you have designated one RPA as a server, go to another RPA, designated it as a client, and use it to test throughput to the server RPA.

System connectivity Only relevant for physical RPAs System connectivity test l

Full mesh network check test communication between any RPA to any other RPA in the system.

l

Check from local RPA to all other RPAs

Advanced connectivity test Tests the connection from a specific IP address on the local appliance to an IP address and port on another RPA anywhere in the system. Show all results from last connectivity check Shows the messages returned by the connectivity test tool. 20

RecoverPoint 4.4 boxmgmt Guide

Diagnostics

Message

Meaning

Machine is down

No communication at all with RPA:

is down

l

Verify that the firewall permits ping (ICMP echo) to the RPA.

l

Ensure RPA is connected and operating.

l

Verify that required ports are open. For a list of ports that must be open for the RPA to operate correctly, refer to the EMC RecoverPoint Security and Networking Technical Notes.

Host connection exists, but RPA is not responding: l

Verify that the RPA is attached to an RPA cluster.

l

Verify that required ports are open. For a list of ports that must be open for the RPA to operate correctly, refer to the EMC RecoverPoint Security and Networking Technical Notes.

Connection to link: protocol: FAILED.

No connection to host using .

Link () FAILED.

The checked connection failed.

All OK

The system connectivity is fine.

SAN diagnostic Run SAN diagnostics As shown

View RPA ports As shown

View target LUNs As shown

Perform I/O to a LUN As shown

SAN diagnostic

21

Diagnostics

Synchronization diagnostics Output similar to the following appears. remote refid st t when poll reach delay offset jitter ====================================================================== ======== *10.10.0.1 10.254.140.22 4 u 2 64 377 0.141 18.094 4.571

The meaning of columns in this output are as follows: remote Host names or addresses of the servers and peers used for synchronization refid Current source of synchronization st The stratum t The type (u = unicast, m = multicast, l = local, - = not known) when Time, in seconds, since the peer was last heard poll Poll interval, in seconds reach Status of the reachability register (see RFC-1305) in octal delay, offset, jitter Shown in milliseconds The symbol in the left margin displays the synchronization status of each peer * Signifies the currently selected peer + Signifies additional peers acceptable for synchronization Peers marked * and + are included in the weighted average computation to set the local clock, while the data produced by peers marked with other symbols is discarded. The LOCAL(0) entry represents the values obtained from the internal clock on the local machine.

Collect system information Failure to establish an IP connection between RPAs to switches will prevent splitter log retention and prevent EMC Customer Service from being able to collect system logs from customers and provide timely and effective support. GMT is not adjusted for daylight saving (summer) time. The maximum collection time interval is 3 days. 22

RecoverPoint 4.4 boxmgmt Guide

Diagnostics

If the entered interval is from more than 30 days ago, some logs may not be available for collection. When collecting system information, the following error conditions apply l

If connection with an RPA is lost while info collection is in process, no information is collected.

l

If the collection from the remote cluster failed because of a WAN failure, run the process locally in the remote cluster.

l

In the event of simultaneous info collection from the same RPA, only the collector that established the first connection can succeed.

l

FTP failure results in failure of the entire process.

Run internal command Depending on user privileges, Run internal command displays the list of available internal commands you are allowed to use.

Run internal command

23

Diagnostics

24

RecoverPoint 4.4 boxmgmt Guide

CHAPTER 5 Cluster operations

l l l l l l

Detach/Attach RPA from/to cluster........................................................................26 Prepare this cluster for connection to an existing cluster....................................... 26 Connect a new cluster to this system.....................................................................26 Remove a cluster from the system......................................................................... 26 Configure connection types to the other clusters in the system..............................26 Remove the link between two clusters...................................................................26

Cluster operations

25

Cluster operations

Detach/Attach RPA from/to cluster The RPA will be rebooted once it is attached.

Prepare this cluster for connection to an existing cluster Only relevant to vRPAs.

Connect a new cluster to this system As shown

Remove a cluster from the system As shown

Configure connection types to the other clusters in the system As shown

Remove the link between two clusters As shown

26

RecoverPoint 4.4 boxmgmt Guide

CHAPTER 6 Shutdown/Reboot operations

l l

Reboot RPA........................................................................................................... 28 Shutdown RPA.......................................................................................................28

Shutdown/Reboot operations

27

Shutdown/Reboot operations

Reboot RPA As shown

Shutdown RPA As shown

28

RecoverPoint 4.4 boxmgmt Guide