Distance between water and power points Regulations,Kitchen sinks and tapware,Kitchen appliances,Plumbing,Bath,Shower,Vanity,Toilet,Bathroom,Kitchen,Laundry

Water is a great conductor of electricity, which can be very dangerous in places like the kitchen, the bathroom or the laundry. There are certain rules and regulations in Australia that govern how switches and outlets can be placed in relation to water outlets and †xtures. Knowing them will help you to decide where the safest places to put your general power outlets (GPOs) are when you begin planning the layout of your bathroom or your kitchen. If you have any doubt about where things should go, consult a licensed electrician - they will know these rules all too well, and MUST be employed to do any electrical work.  

Zones for positioning electrical †ttings around the bath.

Bathroom zones For the purpose of wiring regulations, bathrooms are divided into four zones, in accordance with the Australian/New Zealand Wiring Rules (AS/NZS 3000:2007). These are as follows:

http://www.build.com.au/distance­between­water­and­power­points

1/9

1/5/2016

Distance between water and power points | BUILD

Zone 0 - This covers interior area of the base of the bath or shower. Zone 1 - This zone is divided into three sections, depending on what you have installed: Bath - For a bathtub, Zone 1 is the vertical area from the inner rim of the bath to the ceiling, or 2.5m above the rim, whichever is lower (this usually encompasses zone 0 too). Shower over a bath - The area with a horizontal radius of 1.2m from the †xed plumbing connection of the shower (i.e. 1.2m out from the shower outlet). Shower - The area with a horizontal radius of 1.2m from the †xed plumbing connection of the shower. The vertical boundaries of this area extend from the †oor to the ceiling, or up to 2.5m above the †oor, whichever is lower. Zone 2 - This is the area with a horizontal radius of 0.6m out from Zone 1, and a height of 2.25m above the †oor (or to the ceiling, whichever is lower). Zone 3 - This is the area with a horizontal radius of 2.4m out from Zone 2. The vertical boundaries of this area extend from †oor to ceiling or up to 2.5m above the †oor, whichever is lower.   Testing electrical safety  If you have a hand held shower in your bathroom that has a barrier (like a door or a shower curtain), a good tip to test electrical safety is to test the distance of the water spray when the barrier is in place. If it can reach a power outlet or a switch, then the switch or power outlet probably needs to be relocated.

Zones for positioning electrical †ttings in bathrooms with a shower. Left is a shower with a barrier and †xed wall, right is a shower with only a barrier.

  Zone wiring regulations (sockets) Where you can place sockets and switches in a bathroom depends on the zone: Zone 0 - No sockets are permitted. Zone 1 - No sockets are permitted. Zone 2 - No sockets are permitted unless they're incorporated into a shaver supply unit OR are protected by Residual Current Detectors (RCD) with a †xed rating of not more than 30mA, and in a cupboard (e.g. a vanity http://www.build.com.au/distance­between­water­and­power­points

2/9

1/5/2016

Distance between water and power points | BUILD

cabinet) that maintains the enclosure of the socket outlet during normal operation of the connected equipment. Zone 3 - Sockets are permitted provided that they're installed at more than 0.3m above the bathroom †oor, and †tted with RCD protection. Advertisement

  Zone wiring regulations (switches) Zone 0 - No switches are permitted. Zone 1 - No switches are permitted unless they're installed higher than 0.3m above the bathroom †oor with IPX4 speci†cation. Zone 2 - No switches are permitted unless they're installed higher than 0.3m above the bathroom †oor with IPX4 speci†cation. Zone 3 - No switches are permitted unless they're installed higher than 0.3m above the bathroom †oor. No speci†c IP rating is required.   Light †ttings with an IPX4 speci†cation are only permitted in Zones 1 and 2, while those in Zone 3 don't require a speci†c IP rating.   Kitchen and laundry zones Slightly diဠerent rules apply in other areas of the house like kitchens and laundries around sinks, basins or other †xed water containers. The distance that electrical outlets (GPOs) can be from a sink is determined by how much water it can contain. Sinks, basins or other †xed water containers that hold less than 45 litres have slightly diဠerent rules than those which hold more. For †xed water containers anywhere outside of the bathroom, there are two zones de†ned: Zone 0: The area inside the sink or basin, in which nothing is allowed to be installed. Zone 2: Determined by whether or not the container holds more than or less than 45L - no †ttings are allowed inside zone 2. For containers that hold less than 45L, zone 2 is de†ned as 0.4m above the top of the container, and 0.15m from the edges of the water container. For those that hold more than 45L, it's 1.0m above and 0.5 metres from any given side.

http://www.build.com.au/distance­between­water­and­power­points

3/9

1/5/2016

Distance between water and power points | BUILD

Distances to electrical outlets for †xed water containers.

  Note that these rules only apply for GPOs - other 'switches and accessories' aren't allowed within 300mm of a †xed water container at all, and must be IPX4 rated if they're to be installed at a distance greater than or equal to 300mm from the †xed water container inside zone 2. Consult your electrician for exact details.   Safety switches You can never be too careful where something as volatile as electricity is concerned, especially in a high-risk area like the bathroom. Safety switches monitor the †ow of electricity through a circuit and automatically cut the power supply if current is detected leaking from faulty switches or wiring. While they are not a complete guarantee against electrical shocks, they do work to minimise the damage done, and could make all the diဠerence. Since 1992, all new houses in Australia are required by law to have safety switches installed. There are three types of safety switches available: Switchboard mounted safety switches - These are the most basic of safety switches and monitor the †xed wiring and electrical appliances in your household. It is mandatory by law for every home to have these installed by a quali†ed electrician. Safety switches in place of regular power points - These switches replace your standard GPOs and protect any appliances that are plugged into them. They also need to be installed by a quali†ed electrician. Portable safety switches - These can be used both indoors and outdoors, and are essential to use if you are using electrical appliances that are not protected by one of the safety switches listed above.   A †nal caveat: All electrical work in Australia MUST be done by a licensed electrical contractor, who should properly test any electrical work and supply you with a safety certi†cate.

Share this:

9 Like 

Need a tradie? http://www.build.com.au/distance­between­water­and­power­points

4/9

1/5/2016

Distance between water and power points | BUILD

What do you need done? Where is the job?

Get FREE Quotes

You Might Also Like

Where to position electrical outlets

Height and position of power points

How to plan your bathroom

Wet rooms

http://www.build.com.au/distance­between­water­and­power­points

5/9

1/5/2016

Distance between water and power points | BUILD

Bathroom lighting

What to do in an electrical emergency

Email See previous newsletters

Subscribe

Latest blogs

Roof insulation tips

http://www.build.com.au/distance­between­water­and­power­points

6/9

1/5/2016

Distance between water and power points | BUILD

Understanding The Laws Surrounding Pool Fencing In Victoria

Are Modular Homes Future Proof?

http://www.build.com.au/distance­between­water­and­power­points

7/9

1/5/2016

Distance between water and power points | BUILD

Ready for winter? Outdoor Area Maintenance

Properly Preventing Roof Problems

Checklists Download our complete building and renovation checklists – have you forgotten anything?

Maintenance guide Tools, tips, home maintenance schedules & useful advice to help you maintain your home.

http://www.build.com.au/distance­between­water­and­power­points

8/9

1/5/2016

Distance between water and power points | BUILD

Advertisement

Victoria's SecretVictoria’s Secret Seamless Lace Panties Black (2pcs)Shop now­42%RM 58.23RM Copyright © 2016 Connection Magazines About BUILD

Advertise

http://www.build.com.au/distance­between­water­and­power­points

Contact us

Privacy policy

Terms of use

9/9

View more...

Comments

Copyright ©2017 KUPDF Inc.
SUPPORT KUPDF