Esfuerzos ultimos en Zap.Ext. y Viga Pu1=142.2 Ton 0.25 Wuv(ton/m)=
1.62 2
1
Wnu= 121.39 0.650
6.46
RNu(ton)= 157.81
54.11
Momentos 13.50 0.96
5.14 Cortantes
112.26
ZAP.EXT. d(cms)= recub.= h(mts)=
45.0 7.0 0.52
Verificación por flexión y diseño
Sec.1-1
Sec.2-2
Diseño por flexión Muact= 33.46 ton-m As(cm2)= 22.89 Ø(pulg)= 5/8 s(cms)= 9 Verificación por cortante Vdact= 36.42 to n ΦVc= 38.15 ton Diseño por flexión Muact= 38.85 ton-m As(cm2)= 45.79 Ø(pulg)= 5/8 s(cms)= 4 Verificación por cortante Vdact= 42.49 to n ΦVc= 76.30 ton