Data Recovery From 0 GB Barracuda 7200.11

December 11, 2016 | Author: afgdbhnaf | Category: N/A
Share Embed Donate


Short Description

Solution for Barracuda 7200.11 drives stays BUSY (LBA detected as 0) with Salvation Data software...

Description

SalvationDATA™ Repair Flow for Barracuda 7200.11 with 0 LBA

Page |1

Solution for Barracuda 7200.11 drives stays BUSY (LBA detected as 0) The new feature for Barracuda 7200.11 has been tested for two months and is proved to be effective in repairing such malfunction of Barracuda 7200.11. Now as usual we release the update for free. Please follow the procedures below: 1. First you need to remove the PCB from HDA case and connect it to the HD Doctor Console. Power supply to the PCB should be on

2. Go to CMD mode, use command “Ctrl+Z” to switch the command line prompt to be F3 T>, as follow:

© 2001-2008 SalvationDATA Technology, LLC. Unauthorized copy or distribution of this document is prohibited.

Technical Support: [email protected] http://www.salvationdata.com

SalvationDATA™ Repair Flow for Barracuda 7200.11 with 0 LBA

Page |2 3.

Input command “/2”, press Enter; switch the drive to Level 2.

4.

Input command “Z” and press Enter to stop spindle motor.

5.

Then mount the PCB back to HDA case; DO NOT power off or disconnect the PCB from the HD Doctor Console when doing this step.

© 2001-2008 SalvationDATA Technology, LLC. Unauthorized copy or distribution of this document is prohibited.

Technical Support: [email protected] http://www.salvationdata.com

SalvationDATA™ Repair Flow for Barracuda 7200.11 with 0 LBA

Page |3 6.

In CMD mode, under F3 2> prompt, input command “U” and press “Enter” to start spindle motor.

7.

Input command “/1” and press “Enter” to switch back to Level 1.

8.

Input command “N1” and press Enter.

9.

Perform a power reset, you will see the drive stayed BUSY before is showing READY now.

© 2001-2008 SalvationDATA Technology, LLC. Unauthorized copy or distribution of this document is prohibited.

Technical Support: [email protected] http://www.salvationdata.com

SalvationDATA™ Repair Flow for Barracuda 7200.11 with 0 LBA

Page |4 10. Finally go to New Feature tab specially designed for Seagate 7200.11, Click “Repair LBA=0” button to fix the problem that made the drive’s LBA detected with 0.

For Seagate 7200.11 drives with SMART error, users can make use of the “Repair SMART Error” button to have it fixed. All the above operations won’t damage the data on the patient drive.

© 2001-2008 SalvationDATA Technology, LLC. Unauthorized copy or distribution of this document is prohibited.

Technical Support: [email protected] http://www.salvationdata.com

SalvationDATA™ Repair Flow for Barracuda 7200.11 with 0 LBA

Page |5 For further information, please contact us:

----- America Continent ----Tel: (+86) 28 68599758 Fax: (+86) 28 68107757 Email: [email protected]

----- Europe and Africa ----Tel: (+86) 28 68599759 Fax: (+86) 28 68107757 Email: [email protected]

----- Asia and Oceania ----Tel: (+86) 28 68107757 Fax: (+86) 28 68107757 Email: [email protected]

© 2001-2008 SalvationDATA Technology, LLC. Unauthorized copy or distribution of this document is prohibited.

Technical Support: [email protected] http://www.salvationdata.com