Curso de Antenas - Nokia
Short Description
Descripción: Curso de Antenas - Nokia...
Description
CMO LAT NI SE CoDe SISTEMA DE ANTENAS
NOKIA NODE-B SITE
Antenna Systems Power Systems
Cellular Transmission Systems For internal use 2 © Nokia Siemens Networks
Shelters, Towers, Masts, Poles
Site
Base Stations
Presentation / Author / Date
Installation Materials
ANTENNA LINE
For internal use 3 © Nokia Siemens Networks
Presentation / Author / Date
PRODUCTOS DE SISTEMA DE ANTENAS Antenna
Jumper cable Mast Head Amplifier and BiasT
Connector
Feeder clamps Grounding kit Combiners diplexers
Feeder cable
For internal use Nokia©Auxiliary Product Management v. 1.0 04.2002 Nokia Siemens Networks Presentation / Author / Date
4 4
EMP protector
ANTENNA LINE Instalación de Antenas TM 3G Antenna:
• CS72761.08 (K742212) XPol F 1710-2170M 65deg 18dBi 0-8T • CS72761.11 (K742215) XPol F 1710-2170M 65deg 18dBi 0-10T • CS72191.14 DT-kit for A, F & Euro panel • CS72196 Clamp 50-115mm for A, F & Euro panel
For internal use 5 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Downtilt Electrico Ajustable
Combina las ventajes de poder ajustar el downtilt sin afectar el patron de radiación de la antena.
Downtilt es ajustado usando un rotary knob en la parte inferiro de la antena.
For internal use 6 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE MHA (Mast Head Amplifier)
Incrementa la cobertura Balancea enlace Rx-Tx Mejora la sensibilidad del sistema Disminuye la potencia de transmisión del equipo movil. BTS RX sin MHA BTS RX con MHA
For internal use 7 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Nokia Mast Head Amplifier
Antenna
2 MHAs mounted backto-back
Jumper
Mast Head Amplifier
Bias T Drenaje
For internal use 8 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Beneficios del MHA
Totalmente integrado y probado de acuerdo a los requerimeintos de los sistemas. Compacto y facil de instalar Compensa la perdida por cable y combinadores en el uplink Disminuye la potencia de transmisión del equipo movil. Reduce la interferencia inter-cell e intra-cell For internal use 9 © Nokia Siemens Networks
Presentation / Author / Date
2 MHAs instalados backto-back
Diagrama de Bloques del Mast Head Amplifier BTS
ANTENNA
TX FILTER
Internal BIAS TEE
BYPASS PATH
RXin FILTER
RXout FILTER
DC CURRENT
Current Sense, Bypass & Alarm Control Circuit For internal use 10 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Bias-T
Energiza el MHA atravez de la linea de transmisión. Maneja las alarmas del MHA y del Bias-t
BTS port
Fwd. power coupler
Alarm out DC pwr in
For internal use 11 © Nokia Siemens Networks
DC block (capacitor)
Rvrs. power coupler
Broadband detectors level comparators alarm-sense logic
RF choke (inductor)
Presentation / Author / Date
Lightning protection
ANT port
Lightning protection (MHA + BiasT) BiasT)
ANT. Jumper
MHA
Ant. port
Transorber (fast)
/4 Large area quarter wave stub (>25mm2) (for imped.matching)
LNA LNA
Gas-tube (spark gap) (high energy)
BTS port Jumper Feeder
PTFE tube
BiasT BTS
RF band pass filter DC-Input with large conducting areas For internal use 12 © Nokia Siemens Presentation / Author / Date andNetworks high DC isolation
/4
ANTENNA LINE Instalación del MHA
For internal use 13 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Instalación del MHA Installation con bracket especial
Braket montado en mastil (40-110 mm diameter)
For internal use 14 © Nokia Siemens Networks
Presentation / Author / Date
3 MHAs instalados en el mastil
ANTENNA LINE Colocando el downtilt y orientando las antenas Esta ok??
Tomando un punto de referencia
For internal use 15 © Nokia Siemens Networks
Presentation / Author / Date
Direccionando la antena Iaquierda...Dere cha...-10 grados
ANTENNA LINE Colocando el downtilt y orientando las antenas OK pongamos lo a -6 grados
Vertical
REQUIREMENT +/- 0,5° Antenna Tilting Angle (Mechanical)
For internal use 16 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Mejora del funcionamiento de la Red
Eveluación de las inclinaciones de las antenas
Triple band 824-960 MHz 1710-1880 MHz 1920Dual band 2170 MHz 824-96 & 17102170MHz Broadband 17102170MHz Single band Tilt 1920electrico 2170MHz Polarización ajustable Cruzada Polarización
Tilt Electrico
Vertical Tilt Mecanico
Eficiencia For internal use 17 © Nokia Siemens Networks
Presentation / Author / Date
Nokia RealTil t
ANTENNA LINE Downtilt Mecanico
Antena inclinada fisicamente de tal manera que el lobulo principal se deforma en el piso. La reducción de la señal en la dirección principal pero no cambia el angulo de apertura de la antena. El planeaminto de la red Se dificulta al alterarse el patron de radiación. For internal use 18 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Downtilt Electico
Antena permanece vertical
La fase de la señal que van a los dipolos varia causando el tilt electrico. El patron de radiación no se altera Se agura un exacto planeamiento de red For internal use 19 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Instalación Antenna Ajustando el downtilt mecanico (Kathrein)
• Usar la escala en el kit de downtilt para medir la inclinación. •Confirmar con un medidor de angulo •Si la escala no existe usar un medidor de agulo
For internal use 20 © Nokia Siemens Networks
Presentation / Author / Date
Ajustando el downtilt electrico (Kathrein)
ANTENNA LINE Antenna Line System Item
Descripción
Las antenas pueden ser de polarización vertical, cruzada y direccionales u omni-direccionales Los jumpers son cables flex de ½”, y son usados en los extremos de los coaxiales. Estos protegen los conectores ante posibles movimientos bruscos de los coaxiales. Los conectores 7/16 tienen la clasificación IP68.
1
El kit de tierra asegura que la linea de transmisión tenga protección de DC ante posibles descargas.
2 3
El cable coaxial de RF puede ser de diferentes medidas, ejem. 1/2”, 7/8” , 1 5/8”, etc, dependiendo de la altura de la torre clamps son de acero y plastico. Son facil de instalar. El diseño de los clamps evita que se puedan ajustar demasiado y dañar el cable.
4 5 6 7
Un compacto EMP protégé la BTS ante posibles descargas. (opcional)
Antenna Line System without MHA For internal use 21 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE
Note:The photo shows the “Antenna system” at outdoor site in Singapore.
For internal use 22 © Nokia Siemens Networks
Presentation / Author / Date
Detail
Detail
Detail
Detail
Detail
Detail
Detail
Detail
Detail
SOLUCION DE INSTALACION DE ANTENA
1 SECTOR (X+0+0 (X+0+0) X+0+0) X= cantidad de TRX For internal use 23 © Nokia Siemens Networks
Presentation / Author / Date
2 SECTOR (X+X+0 (X+X+0) X+X+0) X= cantidad de TRX
3 SECTOR (X+X+X X+X+X) (X+X+X) X= cantidad de TRX
ANTENNA LINE Sencillo
OUTDOO R
INDOOR
Revisar el rango de frecuencia del material utilizado Se deben usar conectores aprobados Los conectores deben ser los adecuados de acuerdo al tipo de cable (fabricante) Los cables deben estar etiquetados a ambos extremos Se deben emplear adecuadas herramientas para ensamblar los conectores. Todos los cables deben estar ajustados adecuadamente. For internal use 24 © Nokia Siemens Networks
Presentation / Author / Date
EMP
ANTENNA LINE Con MHA
OUTDOO R
INDOOR
Bias-T
Revisar el rango de frecuencia del material utilizado Se deben usar conectores aprobados Los conectores deben ser los adecuados de acuerdo al tipo de cable (fabricante) Los cables deben estar etiquetados a ambos extremos Se deben emplear adecuadas herramientas para ensamblar los conectores. Todos los cables deben estar ajustados adecuadamente. For internal use 25 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Calculo de la atenuación del coaxial Atenuación en Jumper cable 0.68dB (2 jumpers con 4 conectores) Atenuación en conector de antena ( 2 conectores ) ≤ 0.10 dB Atenuación en EMP dB Atenaución en coaxial
≤ 0.10 RF 7/8“ 5.53 dB 100m RF 1 5/8“ 3.36 dB 100m
Ejemplo: Se tiene un recorido de 36 m. La atenuación limite es Que cable se deb usar? 0.1 + 0.1 + 0.68 + 36m X 0.0553 = ≤ 3 dB -> 7/8" feeder cable
For internal use 26 © Nokia Siemens Networks
Presentation / Author / Date
3 dB.
ANTENNA LINE Atenuación en Coaxiales
CABLE
FREQUENCIA 900 MHz
FREQUENCIA 1800 MHz
FREQUENCIA 2000 MHz
RFF 3/8”-50
13.9 dB/100m
20.5 dB/100m
21.8 dB/100m
RFF 1/2”-50
10.6 dB/100m
15.6 dB/100m
16.7 dB/100m
RF 1/2”-50
6.88 dB/100m
10.1 dB/100m
10.7 dB/100m
RF 7/8” 7/8”-50 !!
3.53 dB/100m
5.04 dB/100m
5.53 dB/100m AVA
RF 1 1/4”-50
2.74 dB/100m
4.12 dB/100m
4.39 dB/100m
RF 1 5/8” 5/8”-50 !!
2.11 dB/100m
3.05 dB/100m
3.36 dB/100m AVA
NOTE: Given values are for NK Cables feeder cables except 7/8” and 15/8” are for Andrew AVA cable type, other manufacturers’ may have different values, check the proper values before implementation from manufacturer’s data sheets For internal use 27 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Intrucciones de instalación de antenas.
1.
Verificar que el soporte de antena este colocado en la posición correcta.
2.
Izar la antena hasta el soporte Nota: Prevenir los problemas que se puedan encontrar debido a condiciones climaticas para evitar que la antena sufra daños.
3.
Instalar la antena totalmente vertical o con la inclinación indicada por planning.
4.
Usar las especificaiones de la antena para tener en cuanta la separación vertical y horizontal con otras antenas.
5.
Conectar el Jumper en la antena, el otro extremo quedara desconectado momentaneamente Nota: proteger el conector libre con cinta.
6.
Colocar clamps en el jumper hacia la antena
For internal use 28 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Curvatura de cables
La curvatura de los cables deben seguir las esécificaciones deNSN para evitar daños y aumentar la perdida en el cable. No permitido: MAL
MAL
For internal use 29 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Curvatura de cables
CABLE
CURVATURA MINIMA PARA UNA SOLA CURVA
CURVATURA MINIMA PARA VARIAS CURVAS
RFF 3/8”-50
13 mm
25 mm
RFF 1/2”-50
15 mm
30 mm
RF 1/2”-50
80 mm
160 mm
RF 7/8”-50
120 mm
250 mm
RF 1 1/4”-50
200 mm
350 mm
RF 1 5/8”-50
250 mm
500 mm
NOTE: Given values are for NK Cables feeder cables, other manufacturers’ may have different values, check the proper values before implementation from manufacturer’s data sheets For internal use 30 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Curvatura de cables
FEEDER TYPE REPEATED
REPEATED BENDING RADIUS
SINGLE BENDING RADIUS
RF 1 5/8”
500mm
250mm
RF 1 1/4”
350mm
200mm
RF 7/8”
250mm
120mm
RF 1/2”
160mm
80mm
RFF 1/2”
30m m 25m m
RFF 3/8”
For internal use 31 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Distancia entre clamps
Seguir las especificaciones de los cables. Cable
Distancia entre clamps Optima
Maxima
1/4” Superflex
150mm
200mm
3/8” Superflex
150mm
200mm
1/2” Superflex
250mm
300mm
1 /2” Feeder
500mm
600mm
7/8” Feeder
900mm
1000mm
1-5/8” Feeder
1000mm
1400mm
NOTE: Given values are for NK Cables feeder cables, other manufacturers manufacturers’ cturers’ may have different values, check the proper values before implementation from manufacturer’ manufacturer’s data sheets For internal use 32 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Distancia entre clamps
Seguir las especificaciones de los cables. RF 1/4” superflex
150mm
200mm (Max)
RF 3/8” superflex
150mm
200mm (Max)
RFF 1/2” superflex
250mm
300mm (Max)
RF 1/2”
RF 7/8”
RF 1 5/8”
For internal use 33 © Nokia Siemens Networks
500mm
600mm (Max)
900mm
1000mm
Presentation / Author / Date
1000mm (Max)
1400mm (Max)
ANTENNA LINE Instalación de coaxial y jumper
For internal use 34 © Nokia Siemens Networks
Presentation / Author / Date
Detail
Detail
Detail
Detail
Detail
Detail
Detail
Detail
Detail
ANTENNA LINE Instalación de cables coaxiales
Tener cuidado con: • Minimo radio de curvatura • Maxima fuerza al jalar los cables • Manejo del carrete de en el que viene el cable • Correcto manejo de las herramientas
For internal use 35 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Herramientas y conectorización
Usar guantes! Revisar el estado de las herramientas Revisar los conectores y su protecció protección contra el agua Revisar las instrucciones de instalació instalación: medición correcta para cortar, etc. Usar las herramientas con cuidado, no ajustar demasiado antes de cortar. cortar. Usar el torque correcto en todas las conexiones.
For internal use 36 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Instalación de cables coaxiales
CRITICO: Tener cuidado al izar los cables, se podria dañar la protección del cable EVITAR: Izar el cable con fuerzas desiguales. USAR: Izamiento con cuidado. TENER CUIDADO CON: Superficies que puedan dañar el cables, curvaturas excesivas, etc
For internal use 37 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Tipo de cable por ditancia
0 m < L < 8 m -RF 1/2" 9 m < L < 35 m
-RF 7/8"
36 m < L < 50 m L > 50m adicionar MHA 5/8"
-RF 1-5/8"
¡Este ejemplo puede variar dependiendo del proyecto.!
For internal use 38 © Nokia Siemens Networks
Presentation / Author / Date
RF 1-
ANTENNA LINE Instalación de clamps
Tener cuidado con superficies con filo ! Clamps AJUSTADOS AL MAXIMO pueden afectar el cable y originar perdidas en el. Tengan cuidado en NO PERDER los anillos de plastico Los cables debern tener como terminación una impedancia de carga (o fuente) resistiva igual a una impedancia caracteristica, generalmente 50 Ω.
For internal use 39 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Instalación del jumper
Incorrecta curvatura
Correcta curvatura
El jumper es fijado Con clamps
Cables sueltos, sueltos, sin fijació fijación
OK For internal use 40 © Nokia Siemens Networks
Presentation / Author / Date
NOK :
ANTENNA LINE Instalación de jumper La distancia de clamps en un jumper es de 500mm Para un jumper de 1.5m , se deben colocar minimo 2 clamps y para un jumper de 3m , se deben colocar minimo 4 clamps. clamps
Jumper de 1.5m 2 clamps ( minimo) minimo)
For internal use 41 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Instalación de jumper
Los jumpers se deben instalar los mas rectos posible Evitar curvas adicionales. Se deben usar las herramientas adecuadas. Los cables deben ser fijados apropiadamente. De preferencia se deben usar cables prefabricados.
For internal use 42 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Conexión de jumpers
Usar las herramientas correctas La conexión de los jumpers deben tener el torque correcto • Conector 7/16” ---- 25Nm
For internal use 43 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Prueba de laboratorio en cables flojos
Efectos de cables flojos: flojos: Tambien los conectores 7/16 son sensibles a los torques correctos. Cuando se afloja un conector, al principio se tendran problemas de intermodulación, luego se perderan valores de retorno. Facilmete se pueden tener perdidas de 6...12dB en los valores de retorno, cuando un conector es ajustado muy suave ( 5...10Nm). Casi toda la potencia pasara atravez del cable, pero se tendran alarmas de VSWR y la perdida por insersión puede llegar a aumentar en 1..2dB.
For internal use 44 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Instalación de jumpers
NOK
OK
OK Jumpe r
For internal use 45 © Nokia Siemens Networks
Jumpe r
Presentation / Author / Date
NOK
ANTENNA LINE Instalación de jumpers
OK
NOK
O K
OK Jumper
For internal use 46 © Nokia Siemens Networks
Jumper
Presentation / Author / Date
NOK
ANTENNA LINE Vulcanizado de conectores
Almecenar cables bajo techo Revisar los extremos de los cables Proteger el extremo del cable despues de cortarlo; de preferencia con cinta vulcanizante Kits de tierra: Sellado IP 67. Terminal del cable de tierra de ser revisado. Revisar que este bien ajustado.
For internal use 47 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Instalación del jumper en BTS
For internal use 48 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Instalación del jumper en BTS
Shorter jumper
Longer jumper
For internal use 49 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Kits de tierra
Detail
Note:The photo shows the “Ground system” at outdoor site in Singapore.
For internal use 50 © Nokia Siemens Networks
Presentation / Author / Date
Detail
Detail
Detail
Detail
Detail
Detail
Detail
Detail
ANTENNA LINE Kits de tierra
“EMP” EMP” para cada linea es opcional Si se usa MHA , solo se usaran kits de tierra Si el tramo vertical es mayor a 40m , se necesita un kit de tierra en la parte central Kit de tierra
Barra de tierra For internal use 51 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Kits de tierra
El kit de tierra siempre se deb ubicar en el tramo recto del cable, nunca en una curva.
Instalación Aceptable
For internal use 52 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Cableado de kits de tierra
EMP GROUNDING BUSBAR
FEEDER ENTRY GROUNDING BUSBAR
For internal use 53 © Nokia Siemens Networks
Presentation / Author / Date
Los EMP o kits de tierra deben ser conectado a una barra de tierra Los cables coaxiales deben tner un kit de tierra antes del pasamuro. Se deben usar las herramientas adecuadas al instalar los kits de tierra Los cables deben ser fijados correctamente
ANTENNA LINE Cableado de kits de tierra
Los EMP o kits de tierra deben ser conectado a una barra de tierra Los cables coaxiales deben tner un kit de tierra antes del pasamuro. Se deben usar las herramientas adecuadas al instalar los kits de tierra Los cables deben ser fijados correctamente
FEEDER GROUNDING BUSBAR
For internal use 54 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Cableado de kits de tierra
Los EMP o kits de tierra deben ser conectado a una barra de tierra Los cables coaxiales deben tner un kit de tierra antes del pasamuro. Se deben usar las herramientas adecuadas al instalar los kits de tierra Los cables deben ser fijados correctamente
FEEDER GROUNDING BUSBAR
For internal use 55 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Conexión a tierra de los EMP
Barra de tierra aislada
A antena
Jumper a BTS
EMP
Cable de tierra de EMP
Hacia la tierra principal
For internal use 56 © Nokia Siemens Networks
Presentation / Author / Date
aislador
ANTENNA LINE Conexión a tierra de los kits de tierra
A antena
Barra de tierra aislada A BTS
Cable de tierra del kit de tierra
A tierra principal
For internal use 57 © Nokia Siemens Networks
Presentation / Author / Date
aislador
ANTENNA LINE Posición de los conectores
El conector no debe tocar la escalerilla. De no ser posible , aislar la escalerilla con cinta aislante.
For internal use 58 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Weather Proofing
Todas las conexiones de los cables coaxiales que esten a la intemperie, deben ser vulcanizados y encintados. Conexiones a encintar: • Coaxial con jumper • Coaxial con antena y MHA • Coaxial con EMP y combinador (en el caso que este a la intemperie) Los kits de tierra de ber ser sellados de acuerdo a las especificaciones. Los pasamuros deben estar correctamente sellados. Asegurar que los torques en las conexiones sean las correctas antes de encintar!
encintados
For internal use 59 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Conexión Feeder con jumper
1. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA. 2. CONEXION DEBE SER ENCINTADA USANDO CINTA VULCANIZANTE HOMOLOGADA 3. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA 20
50
50
20
1. UNA CAPA DE CINTA AISLANTE
2. DOS CAPAS DE CINTA VULACANIZNATE
For internal use 60 © Nokia Siemens Networks
Presentation / Author / Date
3. TRES CAPAS DE CINTA AISLANTE
ANTENNA LINE Feeder to Antenna, Combiner or MHA connection
1. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA. 2. CONEXION DEBE SER ENCINTADA USANDO CINTA VULCANIZANTE HOMOLOGADA 3. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA TIE WRAP 50
20
1. UNA CAPA DE CINTA AISLANTE 2. DOS CAPAS DE CINTA VULACANIZNATE 1. TRES CAPAS DE CINTA AISLANTE For internal use 61 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Feeder to EMP connection
1. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA. 2. CONEXION DEBE SER ENCINTADA USANDO CINTA VULCANIZANTE HOMOLOGADA 3. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA 20
TIE WRAP
50
50
20
1. UNA CAPA DE CINTA AISLANTE 2. DOS CAPAS DE CINTA VULACANIZNATE
For internal use 62 © Nokia Siemens Networks
Presentation / Author / Date
1. TRES CAPAS DE CINTA AISLANTE
ANTENNA LINE Feeder to Grounding kit connection
2. CONEXION DEBE SER ENCINTADA USANDO CINTA VULCANIZANTE HOMOLOGADA 3. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA * Usar este metodo si los kits de tierra no vienen con cintas o sin instrucciones 20
50
100
20
2. DOS CAPAS DE CINTA VULACANIZNATE
1. TRES CAPAS DE CINTA AISLANTE
For internal use 63 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Pasamuros
• Usar sellos apropiados. •Sellar la entrada de cables apropiadamente.
NOK
For internal use 64 © Nokia Siemens Networks
Presentation / Author / Date
ANTENNA LINE Comisionamiento
• Seguir las intrucciones dadas para las mediciones. • Colocar las mediciones en el Site Folder. • Imprimir las graficas en papel A4 y adjuntar al Site Folder. • Tres graficas por pagina • Adjuntar los archivos en formato electronico ANTENNA LINE
RETURN LOSS
RETURN LOSS
RETURN LOSS
For internal use 65 © Nokia Siemens Networks
Presentation / Author / Date