TRUE OR FALSE PLEASE ANSWER THE FOLLOWING QUESTIONS BY CIRCLING "T" FOR TRUE AND "F" FOR FALSE
1.
CRUDE heaters are force draft furnaces T F
2.
CRUDE furnaces are also designed for natural draft T F
3.
CRUDE furnace can run without ID fan T F
4.
CRUDE furnace have four main flame detectors in each pass T F
5.
CRUDE furnace have individual pilot gas flame detectors T F
6.
In normal furnace operation, furnace will trip if all pilot gas flame detector fails T F
7.
Pilot gas pressure low will trip the furnace. T F
8.
Velocity steam may is injected in four locations T F
9.
Emergency steam to coil will open when heater trips. T F
10.
Emergency trip of heater from control room cut off the pass flows, furnace firing and open emergency steam to furnace coil. T F
11.
Furnace will trip if any of the two pass flow measurement for ESD become zero. T F
12.
Leak test is must before re-lighting the burners. T F
13.
Furnace damper operation is either full open or full close. T F
14.
There are 14 nos of soot blowers in each furnace. T F
15.
Soot blowers can be operated from control room. T F
16.
FO/FG valves of individual burner should be fully open. T F
17.
Less atomizing steam will make the FO burner flame short. T F
18.
High skin temperature of the furnace tube indicate scale formation on the tube. T F
21.
Pigging operation cannot be done on-line. T F
22.
Every fired heater is provided with two explosion doors . T F
23.
Flue gas temperature below 177OC can cause corrosion.. T F
25.
VR is measured by Wedge meter. T F
26.
Flue gas leaves the radiant setion at 7250C. T F
27.
CRUDE heatres are equipped with combination type burners. T F
28.
CRUDE heaters have Pre-mix type burners T F
29.
Velocity steam to the radiation inlet is only DCS controlled T F
30.
At the start up of the heater snuffing steam is used to creat draft inside the furnace. T F MP steam is used as snffing steam in the Heaters . T F
31.
B.
MULTIPLE CHOICE PLEASE ANSWER THE FOLLOWING QUESTIONS BY CIRCLING THE BEST ANSWER
Tick the correct answer 1 BMS stands for A Burner material system B Burner management system C Burner Main supply D Burning material smoke 2
Most efficient furnace is A Natural draft furnace B Force draft furnace C Balance draft furnace D Induced draft furnace
3
Most heat transfer zone in the furnace is A B C D
Convection zone Radiation zone Stack Burner floor
4
Heater trip means A Pass flows cut off B Pilot burner put off C Combustion air cut off D Fuel supply cut off
5
Soot blowing is done to A improve furnace efficiency B reduce stack temperature C to remove soot deposited on the tubes D do all the above
6
Excess air in the furnace stack is due to A poor combustion of the fuel B low furnace draught C High box temperature D Air ingress in the furnace
7
In fuel oil burner, more of the atomizing steam
A B C D
Less of the consumption of fuel oil Burner flame will be long Burner flame will be short Burner flame will be Smokey
8
Pilot burner trips on A Low pass flow B FD fan disch flow low C pilot gas pressure low D fuel gas pressure low
9
Maximum coke is removed from heater tubes during A Spalling operation B steam air decoking C On line decoking D Water flushing
10
Heater tubes are due for decoking when A inlet pressure is more B discharge pressure is more C skin temperatures are more than limit D A and C are true
11.
Total nos of heaters tubes in each pass A 22 B 25 C 32 D 29
12.
Total nos of heater tubes in EACH radiation zone A 120 B 110 C 121 D 101
14
Nos. of burners in each zone in crude heaters A 16 B 18 C 14 D 12
15
Velocity steam is injected into the each furnace coil in FO2 at
A B C D
1 point 2 points 3 points 4 points
16
Emergency steam is injected into the each furnace coil at A 1 point B 2 points C 3 points D 4 points
17
Number of skin thermocouple in each pass is A 7 B 3 C 4 D 5
18
Nitrogen leak test facility is provided in the BMS for A Pilot gas header B Fuel Gas header C Fuel Oil Header D Non of the above
19
Velocity steam to the coil should vary as A Increase with the increase in pass flow B Decrease with the decrease in pass flow C Increase with the decrease in the pass flow D All the above
20
First step to take when heater trips A Open emergency steam to coil B Close all the FO/FG burners valves C Reset FG?FO SDV D Purge the furnace
21
Furnace is efficient when oxygen in stack is A 15 m3 / hr B >24 m3 / hr C >30 m3 / hr D >35 m3 / hr
46
Excess air should not be more than A 20 % B 28 % C 30 % D 10 %
48
Coke build up in the heater tube is indicated by high vale of A Skin Temperature B Inlet Pressure C Fuel Consumption D All the Above