Crouzet-M2

November 16, 2017 | Author: shadi2010 | Category: Relay, Power Supply, Automation, Modem, Hvac
Share Embed Donate


Short Description

Download Crouzet-M2...

Description

Logic controller

Provides a wealth of solutions for your applications

Your

tailor-made solution provides a wealth of solutions for your applications. Automation functions such as timing, counting, supervision, temperature control, backup, etc. are now even easier to manage.

Even more preprogrammed functions Millenium II+ integrates the largest function library on the market, now enhanced with even more functions (high-speed counting, tachometer, PID temperature controller, data storage, etc). In addition, Crouzet can also design functions specific to your requirements.

More accessories and extensions adapted to your applications The new Millenium II+ range has been enhanced with accessories and extensions making it easier to communicate with the outside world. From the remote display to the GSM modem, the Millenium II+ simplifies the design of your automation systems.

More adaptations for the perfect solution Already a strong contender with its extensive high-performance generic range, Crouzet can offer you more by adapting its products to your specific requirements. This fits in perfectly with Crouzet’s global customisation policy. Crouzet has the technical expertise to ensure you get the right product to match your exact requirements... at just the right price! 2

Real advantages for your applications!

Machines When it is incorporated in small machines, Millenium II+ brings both greater adaptability and ease of installation. You can take advantage of its communication and accessibility capabilities with its new remote displays and integrate additional functions into your equipment with the greatest of ease.

Building automation With its preprogrammed function blocks, analogue inputs, Motor Control version and its powerful calendar clock, Millenium II+ makes controlling your installations easy, covering heating, air conditioning, pumping and lighting applications as well as access control (gates, management of safety devices, etc).

Discover

our kits

Heating/cooling control lighting control

pumping

heating/ air conditioning

access control

Page 14

STN or GSM modem External and onboard equipment Available in 12 and 24 VDC, Millenium II+ can be used to manage automatic control functions on your industrial vehicles, as well as on your external equipment with its new Clima + version which operates from - 30 to + 70°C

3

An expandable configuration

A 10 volt

Temperature convertor

0

Inputs

Programming

UP DOWN

PWM

Outputs

4

PID

Inputs

Human/Machine interfaces

GSM RTC SMS Modems

MODBUS® Contiguous and Local extensions

10 volt

0

“An optimised range for a tailored solution” 5

The most innovative software on the market Supervise the installation

1

2

3

Select your function Build your program

Function toolkit FBD functions 27 preprogrammed functions are available for counting, timing, comparison, multiplexing, time-based programming and display, etc.

6

BOOLEAN Used to create logic equations between connected inputs.

TIMER BW Timer - BW function (pulse on a rising or falling edge).

GAIN Used to convert an analogue value by changing the scale and offset.

PID Temperature controller.

SET - RESET Bistable memory - Priority assigned to either SET or RESET.

PRESET H-METER Hour Counter (preselection of hour, minute).

DISPLAY Display of digital and analogue data, date, time, messages for man-machine interface.

STORE Storage of data values with an average value.

TIMER A/C Timer - A/C function (Delay on/Delay off).

TIMER Li Pulse generator (ON setting, OFF setting).

TIME PROG Daily, weekly and yearly time programmer.

H-SPEED COUNT High-speed counting 1 kHz for UP-DOWN, 500 Hz for PHASE TACHOMETER function as standard.

UP DOWN COUNT Up/down counter.

TIMER B/H Timer. B/H function. (Adjustable pulsed signal).

BISTABLE Impulse relay function.

PRESET COUNT Preselection up/down counter.

TRIGGER Defines an activation zone with Hysteresis.

MUX Multiplexing functions on 2 analogue values.

COMP IN ZONE Zone comparison (MIN ≤ VALUE ≤ MAX).

COMPARE Comparison of 2 analogue values using the =, >, 22 +/- 5 % +/- 3 LSB 2.2 kΩ / 0.5 W

24 V DC input Current drain Input current Input impedance Pull-in voltage at logic state 1 Drop-out voltage at logic state 0 Response time Galvanic isolation Sensor type Status indicator

24 (+20 % -15 %) V DC 3.2 mA / 5.5 mA max. 6.8 kΩ ≥ 15 V DC ≤ 5 V DC 10 ms No Contact or 3-wire PNP or 3-wire NPN On LCD screen for SA12, SA20 and XT20

12 V DC input Input voltage Input current Input impedance Pull-in voltage at logic state 1 Drop-out voltage at logic state 0 Response time Sensor type Galvanic isolation Status indicator

12 (+30 % -15 %) V DC (except XT20R +30 % -11 %) 1.9 mA / 2.3 mA max. 6.45 kΩ ≥ 8 V DC ≤ 3 V DC 10 ms Contact or 3-wire PNP or 3-wire NPN No On LCD screen for SA12, SA20 and XT20

Analogue input (12 V DC model only) CN12 - SA12 - EC12 CN20-SA20-EC20-XT20 Measurement range Resolution Conversion time (ms) Max input voltage Input impedance (kΩ) Precision Temp. dependent derating Potentiometer control

4 inputs I5 to I8 8 inputs I5 to I12 0 ➞ 10 V 8 bits 10 15.6 V DC > 10 (14 typical) ±5% ± 3 LSB 2.2 kΩ / 0.5 W

Relay output Max. breaking voltage Breaking current Service life Minimum load Response time Status indicator

250 V AC / 30 V DC 8A 8 A / 250 V AC resistive (100.000 operations) 10 mA ➞ 5 V DC 10 ms On LCD screen for SA12, SA20 and XT20

TOR / PWM solid state output PWM solid state output Breaking current Breaking voltage Min. load Maximum inductive load Maximum incandescent load Leakage Response time Insulation PWM frequency PWM cyclic ratio PWM precision at 120 Hz PWM precision at 500 Hz Status indicator

SA12-EC12-CN12 : O1 to O4 SA20-XT20-EC20-CN20 : O1 to O6 5-28.8 V DC 0.7 A / 5-28.8 V DC 1 mA 0.7 A 0.1 A 0.1 mA / 24 V DC 1 ms No 113 Hz to 1807 Hz (user-definable) 0 to 100 % (256 steps) < 5 % (from 15 % to 85 %) load at 10 mA < 10 % (from 20 % to 80 %) load at 10 mA On LCD screen for SA12, SA20 and XT20

13

Starter kit ■ Discover the benefits of Millenium II+ ■ Each kit includes : - a standard (SA) or expandable (XT) Millenium II+ - a PC/Millenium II connection interface - an interactive CD-ROM including the software workshop, tutorial, application library and technical brochures plus for the STN or GSM kits - an STN or GSM modem - a PS24 power supply

Specifications Type SA 12 kit Kit SA 20 Kit XT 20 STN modem kit GSM modem kit

Input 8 PNP 8 12 PNP 12 12 PNP 12 8 PNP 8 PNP

Output 4 relays 4 relays 8 relays 8 relays 8 relays 8 relays 4 relays 4 relays

Supply 24 V DC 100 - 240 V AC 24 V DC 100 - 240 V AC 24 V DC 100 - 240 V AC 24 V DC 24 V DC

Code 88 950 070 88 950 071 88 950 072 88 950 073 88 950 074 88 950 075 88 950 818 88 950 819

Supply 24 V AC 24 V DC

Code 88 950 076 88 950 077

Special starter kits ■ Discover the benefits of Millenium II+ with all the extras needed for your application

■ Each kit includes :

- a Millenium II+ - a programming software CD-ROM - a programming cable plus for the Level Control kit - a level sensor adaptor - 4 S7 level sensors plus for the Temperature Control kit - a PS24 power supply - a -10➞ +150°C remote temperature sensor - a 25A solid state relay with heatsink

Specifications Type Designation Level control kit Level control Temperature Control kit Heating, cooling and air conditioning

14

Standard ■ Intuitive programming via function block (FBD) or grafcet (SFC)

■ Function : timing, counting, etc ■ Application-specific functions : rotation, cam timers, ■ ■ ■ ■ ■ ■ ■

calculation, etc Discrete, analogue or potentiometer inputs Relay, solid state or PWM outputs Backlit LCD display Program password protection Integral calender and clock User-definable from the front panel Non-expandable

Specifications Type SA 12

Input 8 PNP 8 8 8 PNP 8 PNP 8 PNP 8 NPN 12 PNP 12 12 12 PNP 12 PNP 12 PNP 12 NPN

SA 20

Output 4 relays 4 relays 4 relays 4 solid state 4 relays 4 solid state 4 relays 8 relays 8 relays 8 relays 8 solid state 8 relays 8 solid state 8 relays

Supply 24 VDC 100 - 240 VAC 24 VAC 24 VDC 12 V DC 12 V DC 24 VDC 24 VDC 100 - 240 VAC 24 VAC 24 VDC 12 V DC 12 V DC 24 VDC

Code 88 950 041 88 950 043 88 950 044 88 950 042 88 950 045 88 950 046 88 950 049 88 950 051 88 950 053 88 950 054 88 950 052 88 950 055 88 950 056 88 950 059

Dimensions SA 12

SA 20 125 mm

A

B

Esc

O1

O2

O3

OK

82 mm

I1 I2 I3 I4 I5 I6 I7 I8

90 mm

82 mm

90 mm

72 mm L1 N

L1 N

I1 I2 I3 I4 I5 I6 I7 I8

A

B

Esc

I9 I10 I11 I12

OK

O4

59,2 mm

60 mm

112,6 mm

60 mm

General characteristics see page 13

15

Blind ■ No display or parameter-setting buttons ■ Intuitive programming via function block (FBD) or grafcet (SFC)

■ Function : timing, counting, etc ■ Application-specific functions : rotation, cam timers, ■ ■ ■ ■

calculation, etc Discrete, analogue or potentiometer inputs Relay, solid state or PWM outputs Program protected by a password Integral calendar and clock

Specifications Type EC12

Input 8 PNP 8 8 8 PNP 8 PNP 8 PNP 8 NPN 12 PNP 12 12 12 PNP 12 PNP 12 PNP 12 NPN

EC 20

Output 4 relays 4 relays 4 relays 4 solid state 4 relays 4 solid state 4 relays 8 relays 8 relays 8 relays 8 solid state 8 relays 8 solid state 8 relays

Supply 24 VDC 100 - 240 VAC 24 VAC 24 VDC 12 V DC 12 V DC 24 VDC 24 VDC 100 - 240 VAC 24 VAC 24 VDC 12 V DC 12 V DC 24 VDC

Dimensions EC 12

EC 20 125 mm

72 mm L1 N

90 mm O1

O2

O3

60 mm

General characteristics

16

I9 I10 I11 I12

O4

59,2 mm

see page 13

I1 I2 I3 I4 I5 I6 I7 I8

82 mm

I1 I2 I3 I4 I5 I6 I7 I8

82 mm

90 mm

L1 N

112,6 mm

60 mm

Code 88 950 021 88 950 023 88 950 024 88 950 022 88 950 025 88 950 026 88 950 029 88 950 031 88 950 033 88 950 034 88 950 032 88 950 035 88 950 036 88 950 039

Expandable ■ Expandable : communication, I/O, etc ■ Can take an XC adjacent extension and an XL local extension

■ Intuitive programming via function block (FBD) or grafcet (SFC)

■ Function : timing, counting, etc ■ Application-specific functions : rotation, cam timers, ■ ■ ■ ■ ■ ■

calculation, etc Discrete, analogue or potentiometer inputs Relay, solid state or PWM outputs Backlit LCD display (XT 20 only) Program password protection Integral calender and clock User-definable from the front panel (XT 20 only)

Specifications Type XT 20

Input 12 PNP 12 12 12 PNP 12 PNP 12 PNP 12 NPN 12 PNP 12 12 12 PNP 12 PNP 12 PNP 12 NPN

EX 20

Output 8 relays 8 relays 8 relays 8 solid state 8 relays 8 solid state 8 relays 8 relays 8 relays 8 relays 8 solid state 8 relays 8 solid state 8 relays

Supply 24 V DC 100 - 240 V AC 24 V AC 24 V DC 12 V DC 12 V DC 24 V DC 24 V DC 100 - 240 V AC 24 V AC 24 V DC 12 V DC 12 V DC 24 V DC

Code 88 950 061 88 950 063 88 950 064 88 950 062 88 950 065 88 950 066 88 950 069 88 950 831 88 950 833 88 950 834 88 950 832 88 950 836 88 950 837 88 950 839

Dimensions XT 20

EX 20

A

B

Esc

125 mm L1 N

I9 I10 I11 I12

OK

112,6 mm

60 mm

I1 I2 I3 I4 I5 I6 I7 I8

I9 I10 I11 I12

82 mm

I1 I2 I3 I4 I5 I6 I7 I8

90 mm

82 mm

90 mm

125 mm L1 N

112,6 mm

60 mm

General characteristics see page 13

17

Bare board ■ For mass-production applications ■ Intuitive programming via function block (FBD) or grafcet (SFC)

■ Function : timing, counting, etc ■ Application-specific functions : rotation, cam timers, ■ ■ ■ ■

calculation, etc Discrete, analogue or potentiometer inputs Relay, solid state or PWM outputs Program protected by password Integral calendar and clock

Specifications Type CN 12

Input 8 PNP 8 8 8 PNP 8 PNP 8 PNP 8 NPN 12 PNP 12 12 12 PNP 12 PNP 12 PNP 12 NPN

CN 20

Output 4 relays 4 relays 4 relays 4 solid state 4 relays 4 solid state 4 relays 8 relays 8 relays 8 relays 8 solid state 8 relays 8 solid state 8 relays

Supply 24 V DC 100 - 240 V AC 24 V AC 24 V DC 12 V DC 12 V DC 24 V DC 24 V DC 100 - 240 V AC 24 V AC 24 V DC 12 V DC 12 V DC 24 V DC

Dimensions CN 12

CN 20 125 mm

59,2 mm

42 mm

General characteristics see page 13

18

82 mm

90 mm

82 mm

90 mm

72 mm

112,6 mm

42 mm

Code 88 950 001 88 950 003 88 950 004 88 950 002 88 950 005 88 950 006 88 950 009 88 950 011 88 950 013 88 950 014 88 950 012 88 950 015 88 950 016 88 950 019

Motor control ■ All Millenium II+ functions with, in addition : - control and braking of one or two DC motors - mixed relay and solid state outputs - 15A relay outputs

Specifications Type SA 4R SA 4R2T

Designation 1 DC motor control 2 DC motors control

Input 8 PNP 12 PNP

Output 4 relay outputs (2 mounted in H layout) 4 relay outputs (2x2 mounted in H layout) & 2 PWM outputs

Supply 24 VDC 24 VDC

Code 88 950 880 88 950 881

General characteristics Electrical characteristics Operating voltage Maximum inrush current Immunity from micro power cuts (ms) Absorbed power (W)

24 VDC +20 % / -15 % 7A 1 88 950 880 : 3.5 88 950 881 : 4

Relay output Relay outputs

88 950 880 : 2 x 8A NO, 2 x 15A NO/NC 88 950 881 : 4 x 15A NO/NC 10 mA / 5 VDC (for 8 A relay) 100 mA / 10 VDC (for 15 A relay) 250 VAC 88 950 880 : 8 A / 15 A 88 950 881 : 15 A 30 x 106 53.000 operations 16 A / 250 VAC resistive NC contact 6000 operations 20 A / 250 VAC N/O contact 30.000 operations 20 A / 24 VDC resistive Yes 90/10 AgNi 10

Min. load Maximum breaking voltage Max. current (A) Mechanical life (operations) Electrical life

Insulation Type of contacts Response time (ms) Logic outputs / PWM PWM solid state output Minimum load Breaking voltage Breaking current Maximum inductive load Leakage current Response time (ms) Insulation PWM frequency PWM cyclic ratio PWM precision at 120 Hz PWM precision at 500 Hz Indicator

O5, O6 1 mA 5 - 28.8 VDC 0.7 A / 5 - 28.8 VDC 0.7 A 0.1 mA / 24 VDC 1 No 113 Hz ➞ 1807 Hz 0 ➞ 100 %
View more...