Cps Terminal Rg-1000 User Manual

April 15, 2017 | Author: SmartPTT | Category: N/A
Share Embed Donate


Short Description

Download Cps Terminal Rg-1000 User Manual...

Description

"Terminal RG-1000" Customer Programming Software User Guide August 2016 R4.3

Table of Contents

Table of Contents Introduction

2

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

3

1.1 Software installation

3

1.2 Connecting the RG-1000 GATEWAYs to the computer's USB port

3

1.3 RG-1000 CPS interface and main features

4

1.3.1 RG-1000 CPS control panels

4

1.3.2 Operation with configuration files

5

1.3.3 Getaway panel

6

1.3.3.1 Network section

6

1.3.3.2 Radio section

11

1.3.3.3 Statistics section

21

1.3.3.4 Monitor section

23

1.3.3.5 Info section

24

2 MOTOTRBO radio settings

25

3 SmartPTT Radioserver settings

30

3.1 Radioserver configuration to interact with the remote control stations in direct communication mode or with the use of single repeater (IP Site Connect network)

30

3.2 Radioserver configuration to interact with the remote control stations in the Capacity Plus Legacy mode

35

3.3 Radioserver configuration to interact with the remote control stations in the NAI Capacity Plus and NAI Linked Capacity Plus hybrid modes

36

Appendix I Manual installation of RG-1000 GATEWAY's driver in Windows 8/8.1/10

"Terminal RG-1000" Customer Programming Software

39

Introduction

Introduction This guide describes the following features: · how to install RG-1000 CPS, · how to connect the RG-1000 GATEWAY to the computer's USB port, · RG-1000 CPS interface and main features, · MOTOTRBO radio parameters to work with a RG-1000 GATEWAY, and · SmartPTT Radioserver settings to work with a RG-1000 GATEWAY.

"Terminal RG-1000" Customer Programming Software

2

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

3

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS) RG-1000 CPS is intended for the specialist engineers who perform the RG-1000 GATEWAY configuration for remote management of the control radio station. When reading the RG-1000 GATEWAY configuration, RG-1000 CPS defines the gateway type automatically. RG-1000 CPS enables you to perform the following basic features: · To gain access to the RG-1000 GATEWAY's configuration (download, read, write) and its modification. · To update and recover the RG-1000 GATEWAY's processor program. · To control the remote radio stations over the IP network. RG-1000 CPS is designed for operation in Windows XP, Windows 7, Windows 8/8.1, Windows 10. Note: RG-1000 CPS R4.3 can be used only for the RG-1000 GATEWAYs with firmware version R4.3.

Attention! The examples shown in the figures below correspond to the standard RG-1000 GATEWAY configuration for control of one radio station of DM 46xx, XiR M86xx, XPR 5xxx series or DGM 8xxx/ DGM 5xxx series connected to the RG-1000 GATEWAY via the RADIO interface.

1.1 Software installation To install RG-1000 CPS, copy the Program folder from the unpacked distribution kit to your local disk and run the RG-1000-XVXX.exe file. When copying the folder with the program, the program does not change the settings of the computer's operation system, except for the installation of the gateway driver for the USB port.

1.2 Connecting the RG-1000 GATEWAYs to the computer's USB port Before connecting the gateway make sure that the computer and gateway have a common ground or one of them is disconnected from the ground. If the RG-1000 GATEWAY and computer are connected to different grounding mats, damage to the USB ports may occur.

"Terminal RG-1000" Customer Programming Software

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

4

When you connect the RG-1000 GATEWAY to a USB port for the first time, the computer's operation system will define the connection of the new device. Now you should install the new device driver. You can install the device driver in two ways (depends on Microsoft Windows OS): · installing the setup driver files from the Driver folder, which is located in program home directory, or · performing Update Driver Software via PC Device Manager. Having installed the driver, you are able to modify the RG-1000 GATEWAY configuration via the computer's USB port. When installing the USB driver in Windows 7/8/8.1/10 operating systems, you must have the computer's administrator rights. Note: In Windows 8 or later, you need to install the USB driver manually after disabling the digital signature verification for the drivers. A step by step installation procedure is provided in Appendix I.

1.3 RG-1000 CPS interface and main features 1.3.1 RG-1000 CPS control panels RG-1000 CPS has two panels: · The RG-1000 (getaway) panel for operation with the RG-1000 GATEWAY configuration. · The Report panel for program messages output. · The File panel allows you to create, open and save the configuration files by clicking the Create , and Save

or Save as

, Open

buttons correspondingly.

You can also perform these actions via the File menu in the main menu of the program. · The Tasks panel allows you to read and write the gateway configuration, by clicking the Read

, Write

buttons correspondingly. It also allows you to update the RG-1000 GATEWAY firmware, by clicking the Download firmware

button (available in the Service mode only).

You can also perform these actions via the Tasks menu in the main menu of the program or via the Tasks menu on the gateway panel.

"Terminal RG-1000" Customer Programming Software

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

5

To open the required panel, click Panels in the main menu of the program or right click in the area of the main menu and click the corresponding panel name. When downloading the RG-1000 GATEWAY configuration, the corresponding panel is opened automatically. To hide the panel, click its Cross button or click Panels or right click in the area of the main menu and click the required panel name.

1.3.2 Operation with configuration files RG-1000 CPS enables you to work with a gateway configuration file in MCD format contains the settings defining the RG-1000 GATEWAY operation via the RG-1000 (getaway) panel. You can perform the following actions with the configuration files: · create configuration file with the default settings, · open configuration file, · save configuration file, · read configuration from the RG-1000 GATEWAY, and · write configuration to the RG-1000 GATEWAY. To create a configuration file: 1. Click File > Create, or click Create in the File panel, or press Ctrl+N together. At that, the RG-1000 CPS window will open. 2. In case of gateway configuration file creation, click Yes in the window that opened. To open the configuration file: 1. Click File > Open, or click Open in the File panel, or press Ctrl+O together. At that, the Open file window will open. 2. Select the required file and click Open. To save the configuration file: 1. Click File > Save, or click Save in the File panel, or press Ctrl+S together. At that, the RG-1000 CPS window will open. 2. Specify the file name in the corresponding field and click Save. You can also save the configuration file by clicking File > Save as, or clicking Save as in the File panel. In this case, you will need to select the type of the configuration file in the Save file window in the File type field. To read the configuration from the RG-1000 GATEWAY, click Tasks > Read, or click Read in the Tasks panel. To write the configuration to the RG-1000 GATEWAY, click Tasks > Write, or click Write in the Tasks panel.

"Terminal RG-1000" Customer Programming Software

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

6

1.3.3 Getaway panel The Getaway panel has the tree structure, which is created when creating the RG-1000 GATEWAY configuration file or reading the configuration from the RG-1000 GATEWAY. This tree structure combines the sections of gateway devices with various RG-1000 GATEWAY configuration operations. The Getaway panel helps to perform the following RG-1000 GATEWAY configuration operations: · reading / writing configuration files and updating the RG-1000 GATEWAY firmware, · modifying the settings, and · getting statistic reports on the operation of gateway modules. To perform these operations, double-click the corresponding section in the panel tree: · the Tasks section contains the operations listed in the Tasks panel description, · the Network section, · the Radio section, · the Statistics section, · the Monitor section, · the Info section.

1.3.3.1 Network section The Network section contains the following gateway network parameters: · eight IP channels, · IP channel connection to the RG-1000 GATEWAY interfaces in the Mux subsection, and · Ethernet port operation mode in the Driver subsection.

IP channel The IP channel window contains the network parameters of the corresponding IP channel. Note: When the RG-1000 GATEWAY uses several IP channels, the TCP and UDP port number values must not coincide.

"Terminal RG-1000" Customer Programming Software

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

7

To open the IP Channel window, double-click the required IP Channel on the RG-1000 panel.

The RG-1000 GATEWAYs have the following parameters: · Mode/connection protocol, has following values - Server mode, the mode for operation with SmartPTT Radioserver. - TCP / RTP, the protocol for operation with SmartPTT Radioserver. - Client mode, the mode is not used with SmartPTT Radioserver. - M-270/LCP, the protocol is not used with SmartPTT Radioserver. Client mode and M-270/LCP are used when Radio Interface Mode is defined as Repeater. See chapter 1.3.3.2 Radio section / Settings. See an additional document how to configure RG-1000 GATEWAYs to use Radio ports in Repeater mode.

· Getaway settings - IP address, Subnet mask, Gateway: The network parameters. - XCMP port protocol: UDP / TCP control command ports in accordance with the connection protocol. - RTP thread ports - Audio: The port of audio signal transmission from radio station to radioserver and backwards over the RTP streams. This port is used for operation with the TCP / RTP connection protocol.

"Terminal RG-1000" Customer Programming Software

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

8

- ARS: The transmission port of data on registration of MOTOTRBO subscribers in the network. This port is used for operation with the TCP / RTP connection protocol. - TMS: The transmission port of text messages between the MOTOTRBO subscribers and readioserver. This port is used for operation with the TCP / RTP connection protocol. - Location: The transmission port of requests and messages about the location of MOTOTRBO subscribers (GPS). This port is used for operation with the TCP / RTP connection protocol. - Telemetry: The transmission port of requests and messages about the state of MOTOTRBO radio stations telemetry contacts (GPS). This port is used for operation with the TCP / RTP connection protocol. If you need to separate the streams of transmitting data, you must assign different values to the UDP port numbers. · Remote getaway settings. It is not used with SmartPTT Radioserver. - IP address, the address of remote RG-1000 GETAWAY - XCMP port protocol, the port of remote remote RG-1000 GETAWAY. These settings are used when Radio Interface Mode is defined as Repeater. See chapter 1.3.3.2 Radio section / Settings. See an additional document how to configure RG-1000 GATEWAYs to use Radio ports in Repeater mode).

Mux The Mux window serves for the IP channel distribution between the RG-1000 GATEWAY interfaces. The IP channels, not connected to any interface, are considered to be disabled and are not used by the RG-1000 GATEWAY. The IP channels that are not used by the RG-1000 GATEWAY must be disabled. To open the Mux window, double-click Mux on the RG-1000 panel.

"Terminal RG-1000" Customer Programming Software

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

9

In the given example of the Mux window you can see that: · Radio 1 interface is connected to IP channel 1. · Radio 2 interface is connected to IP channel 2. You may assign several IP Channels for Radio 1 and Radio 2. For instance, two SmartPTT radioservers may communicate with Radio 1 via IP Channel 1 and IP Channel 3. For this case you should check boxes IP Channel 1 and IP Channel 3 for Radio 1 in the Mux window.

Driver The Driver window serves for the management of the following LAN RG-1000 GATEWAY operation modes: · MDI/MDIX: The type of the connecting Ethernet cable, straight-through or crossed cable. · Auto-Negotiation: Auto-negotiation of data transmission speed and mode. · Fixed values of data transmission speed and mode.

"Terminal RG-1000" Customer Programming Software

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

10

To open the Driver window, double-click Driver on the RG-1000 panel.

When the Ethernet interface operates, side emission from the local network cable can penetrate into the radio station receiver antenna. On some frequencies it can lead to radio station receiving of interference from the RG1000 GATEWAY Ethernet interface. To reduce side emissions, the RG-1000 GATEWAY enables the user to control the Ethernet interface transmitter power. Power reduction decreases the emission level from the Ethernet cable. But it also can lead to the error increase in the Ethernet packets reception depending on the connected network equipment. You must check experimentally the compatibility and operational reliability of network equipment in partial operation mode. You can set the transmitter power for operation with 5 meter cable only in exceptional cases, and you must control the processes of reception and transmission of the Ethernet packets.

"Terminal RG-1000" Customer Programming Software

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

11

1.3.3.2 Radio section The Radio section contains the interface parameters for the radio station connection to the RG-1000 GATEWAY.

The parameter control is performed via the following subsections: · Radio 1: It serves for operation mode control of digital lines and analog inputs/outputs of the RG-1000 GATEWAY RADIO connector. · Radio 2: It serves for operation mode control of digital lines and analog inputs/outputs of the RG-1000 GATEWAY ACCESSORY connector. · Decoders microphone: It serves for operation mode control of the audio decoder of the corresponding IP channel. · Recorder: It serves for operation mode control of the recorder of the corresponding IP channel. Both the Radio 1 and Radio 2 subsections have the Settings, Receiver input, Encoder reciever, Microphone output settings panels, which are described below.

Settings The Settings window defines operation modes of the RG-1000 GATEWAY interface lines depending on the type of connecting control panel or radio station model. RG-1000 GATEWAY general settings include the following components: · Selection of the interface operation mode. · Disabling / enabling of synchronization of control command transmission over IP channels. · Synchronization timer.

"Terminal RG-1000" Customer Programming Software

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

12

To open the Settings window, double-click Settings on the RG-1000 panel in the Radio section.

Mode tab: · Interface mode: This mode defines the interface operation mode for data exchange and radio station management. In the current version it can operate in the following modes: o Disabled: The RG-1000 GATEWAY does not use the given interface. o Motorola DM: The RG-1000 GATEWAY lines are set to operate with MOTOTRBO radio station (see the supported models in the "RG-1000—Radio Remote Gateway" user guide, Table 1 RG-1000 GATEWAY Technical parameters). o Repeater: This mode allows for several RG-1000 GATEWAYs communicate directly to each other and create simplest distributed radio networks. See an additional document how to configure RG-1000 GATEWAYs to use Radio ports in Repeater mode. Note: The Transit audio, Radio ID, Motorola GM modes are not supported. · Sync IP channels: This mode enables to synchronize command transmission when operating with several radioservers. The commands are transmitted serially, after receiving the command reception confirmation from all remote radio stations. If the confirmation is not received from at least one radio station, the other command transmission will be blocked for The synchronization timer IP channels time. · The synchronization timer IP channels: This mode sets the hold time of the command reception confirmation from all remote radio stations. Recommended value is 500 ms. · Transmitting Mic Audio to selected IP channels (while PTT is active): This option allows to share Radio 1 (or Radio 2) voice traffic between multiple SmartPTT radioservers. For instance, SmartPTT radioserver 1 is

"Terminal RG-1000" Customer Programming Software

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

13

connected to Radio 1 via IP Channel 1 and SmartPTT radioserver 2 is connected to Radio 1 via IP channel 3. To share all voice traffic from Radio 1 between both radioservers you should check proper boxes. Note: for correct voice sharing operation you should also configure Encoder microphone section. The Settings tab defines the additional gateway interface settings accordance with the selected operation mode.

PTT control mode: The selection of control mode between the discrete line or XCMP command transmission via USB. It is recommended to use the Discrete output mode. Ports network service radio: The radio station UDP port numbers, used for data transmission of corresponding services. These port numbers must coincide with ports of services which are written in the MOTOTRBO Customer Programming Software (CPS) and radioserver settings for the given connection (see step 4 in the MOTOTRBO radio settings section).

"Terminal RG-1000" Customer Programming Software

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

14

Receiver input The Receiver input window defines settings of the RG-1000 GATEWAY analog inputs. To open the Receiver input window, double-click Receiver input on the RG-1000 panel in the Radio section.

· Input: o Main: It is a line level and unbalanced input that is connected to the radio station Rx Audio output. Recommended setting when connecting the MOTOTRBO radio station is –12 dB. o Additional: It is a balanced input with external attenuator for receiver signal input from the radio station speaker. It corresponds to the radio station Spkr- and Spkr+ outputs. · Amplifier: If it is required, it can provide the input signal gain. Rated input signal level without gain is 330 mV. Recommended gain gateway value for the MOTOTRBO radio stations is 6 dB. Input overload control is performed on the base of input oscillograms in the Monitor > Audio input section of the corresponding interface.

Encoder reciever The Encoder Receiver windows define the settings of the input audio signal coding (for Radio 1 and Radio 2 independently).

"Terminal RG-1000" Customer Programming Software

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

15

To open the Encoder Receiver window, double-click Encoder Receiver on the RG-1000 panel in the Radio 1 or Radio 2 section.

· Control: o Fixed: The continuous audio processing. o Control from CSQ: The audio processing on condition that radio station is in receive/rest mode. This mode is recommended and used to reduce traffic, transmitted into IP network. · The encoding mode: o Mu-Law / A-Law 64 kbps: The audio processing by G.711 standard. SmartPTT supports only Mu-Law 64 kbps encoding mode. Note: Only when Radio Interface Mode is defined as Repeater (standalone mode without SmartPTT radioserver using) the 6.0...18.2 kbps, 128 kbps modes may be used. · Duration audio package: The total duration of audio data in the generated packet, recommended setting is 20 ms.

Microphone output The Microphone output window defines the analog output parameters. Selector signals enables the connection of signals from different audio channels to the output.

"Terminal RG-1000" Customer Programming Software

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

16

To open the Microphone output window, double click Microphone output on the RG-1000 panel in the Radio section.

Recommended settings for MOTOTRBO mobile radios are –11 dB for Microphone outputs and 0 dB of gain value for Amplifier.

Encoder microphone The Encoder Microphone windows define the settings of the audio stream using for voice traffic sharing between multiple SmartPTT radioservers. (for Radio 1 and Radio 2 independently).

"Terminal RG-1000" Customer Programming Software

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

17

To open the Encoder Microphone window, double-click Encoder Microphone on the RG-1000 panel in the Radio 1 or Radio 2 section.

· Control: o Fixed: The continuous audio processing. o Control from PTT: The audio processing on condition that Radio 1(2) is transmit mode. · The encoding mode: o Mu-Law / A-Law 64 kbps: The audio processing by G.711 standard. SmartPTT supports only Mu-Law 64 kbps encoding mode. o 128 kbps: Not used with SmartPTT. · Duration audio package: The total duration of audio data in the generated packet, recommended setting is 20 ms.

"Terminal RG-1000" Customer Programming Software

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

18

Decoders microphone The Decoders microphone windows define buffer sizes of audio decoders for jitter compensation of received audio data packets (for each IP Channel independently). To open the desirable IP Channel Decoder microphone window, double-click Decoders microphone on the RG1000 panel in the Radio section, and next double-click required Channel for setting.

In case of big packet jitter in the IP network, it is recommended to change the audio decoder parameters of working IP channels: · Managing the duration of the buffer: Select Adaptive. · Limit duration of the buffer: Select 3-4 times greater than maximum value of packet jitter in the IP network.

Recorder The Recorder section combines the control parameters and regulators of audio signals transmitted to output for communications recorder connection. Note: Attention! The given settings do not influence on the interaction of RG-1000 GATEWAY and radioserver, they are necessary only for third-party devices connection to the RG-1000 GATEWAY. To open the Recorder window, double-click Recorder on the RG-1000 panel.

"Terminal RG-1000" Customer Programming Software

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

19

The Control tab provides a choice of digital signals for audio signal enabling/disabling.

It is recommended to select all check boxes in the Radio 1, the control signals and Radio 2, the control signals sections of the Control tab.

"Terminal RG-1000" Customer Programming Software

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

20

The Signals tab contains the selector of audio signals incoming to the recorder and variable output amplifier with control interval from 0 to 9 Db. The selector channels have variable attenuators with control interval from -78,3 to 0 Db.

To forward to Recorder port audio only from Radio Port, select the Receiver 1 and Microphone 1 check boxes only. To record audio from Accessory Connector, select the Receiver 2 and Microphone 2 check boxes only. You may keep signal levels settings with 0 dB of gain value, as it is shown on the picture above.

"Terminal RG-1000" Customer Programming Software

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

21

1.3.3.3 Statistics section This section provides useful technical information which helps to perform RG1000 GETAWAY configuration. The Statistics section combines statistic reports on the operation of the following components: · controller, · interfaces for connection of radio station or control terminal, · network interface, and · IP channels. To start/stop reporting from the RG-1000 GATEWAY, click the Start or Stop button in the window of corresponding report. The statistic data is updated periodically at 1 second intervals. Statistic counters are of 32 bits, if the counter is overflowed, the counter will be reset and it will continue to count. To reset the counter to "0", click Reset in the report window.

Common The Common window contains the reports on the loading status of the RG-1000 GATEWAY processors and on network interface status. To open the Common window, double-click Common on the RG-1000 panel in the Statistics section. Click Start to see real-time Common information. Click Stop to terminate monitoring process.

Radio The Radio window contains the reports on the interface operation mode, connected IP channels and other data on operation. To open the Radio window, double-click the required Radio on the RG-1000 panel in the Statistics section. Click Start to see real-time information about the selected Radio. Click Stop to terminate monitoring process.

"Terminal RG-1000" Customer Programming Software

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

22

Network The Network window contains the information on: · the operation of network interface driver, · the operation of network protocols, and · received and transmitted data for the Radio interfaces. To open the Network window, double-click Network on the RG-1000 panel in the Statistics section. Click Start to see real-time information about the Network. Click Stop to terminate monitoring process.

IP channel The IP Channel window contains the report on the operation of data transmission protocol and audio decoder of the corresponding IP channel. To open the IP Channel window, double-click the required IP Channel on the RG-1000 panel in the Statistics section.

Click Start to see real-time information about the IP Channel. Click Stop to terminate monitoring process.

"Terminal RG-1000" Customer Programming Software

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

1.3.3.4 Monitor section The Monitor section combines the windows of input and output oscillograms of the RG-1000 GATEWAY interface audio signals. The oscillograms are output in real time at sampling frequency of 8 kHz. To open the oscillogram window, click the required Audio input or Audio output on the RG-1000 panel in the Monitor section. You can see the example of the oscillogram for Audio input 1 below.

"Terminal RG-1000" Customer Programming Software

23

1 "Termnial RG-1000" Customer Programming Software (RG-1000 CPS)

24

1.3.3.5 Info section The RG-1000 Info window contains the RG-1000 GATEWAY model description, serial number and numbers of processor software versions. To open the RG-1000 Info window, double-click RG-1000 Info on the RG-1000 panel.

"Terminal RG-1000" Customer Programming Software

2 MOTOTRBO radio settings

25

2 MOTOTRBO radio settings This section describes the radio settings that are directly related to the interaction with a RG-1000 GATEWAY and does not cover all other radio settings. Firmware version of the MOTOTRBO radio connected to a RG-1000 GATEWAY can't be older than R02.40.10. Before connecting the MOTOTRBO radio to the RG-1000 GATEWAY in the MOTOROLA DM mode, it is required to configure the following radio parameters in MOTOTRBO CPS: 1. Set up the accessory connector modes. Click the Accessories tab in the radio settings and in the Top section specify the following values: · Select Filtered Squelch in the RX Audio Type field, and · Select Rear PC & Audio in the Cable Type field.

2. In the Top section of the Accessory tab specify the following values for Pin #17: · Select Ext Mic PTT in the Feature column, and

"Terminal RG-1000" Customer Programming Software

2 MOTOTRBO radio settings

· Select Low in the Active Level column.

"Terminal RG-1000" Customer Programming Software

26

2 MOTOTRBO radio settings

27

3. Click the Network tab in the radio settings. In the Radio Network section, select Via USB in the Forward to PC field.

4. In the Network tab, ensure that the UDP ports values of the Telemetry, ARS, TMS and Location services match the corresponding values, configured in the gateway (see the Settings tab of the Settings subsection in the Radio section of the Controller panel). Check the values in the following fields: · the Telemetry UDP Port field in the Radio Network section, · the ARS UDP Port field in the Services section,

"Terminal RG-1000" Customer Programming Software

2 MOTOTRBO radio settings

· the TMS UDP Port field in the Services section, and

"Terminal RG-1000" Customer Programming Software

28

2 MOTOTRBO radio settings

· the Location Server UDP Port field in the Control Station section.

"Terminal RG-1000" Customer Programming Software

29

3 SmartPTT Radioserver settings

30

3 SmartPTT Radioserver settings The SmartPTT Radioserver can be configured in different ways to work with the RG-1000 GATEWAY. It depends on the topology of the MOTOTRBO network to which the radioserver is connected.

3.1 Radioserver configuration to interact with the remote control stations in direct communication mode or with the use of single repeater (IP Site Connect network) Radio network topologies and examples of SmartPTT dispatching systems for this radioserver configuration are described in details in the "RG-1000—Radio Remote Gateway" user guide. See the following sections in the guide: · "Direct Mode communication between the radio stations (Talkaround) in digital or analog mode", and · "System topology with the use of a single repeater or the IP Site Connect network". For connection to each of the preconfigured IP channels on the RG-1000 GATEWAY, a separate connection on the radioserver (remote MOTOTRBO control station) should be created. To create the connection to the RG-1000 GATEWAY in the Direct Mode communication between the radio stations or for working with the repeater, configure the following settings in SmartPTT Radioserver Configurator: 1. Right click Control Stations in the setting tree of SmartPTT Radioserver Configurator. 2. Click Add > Remote MOTOTRBO control station.

"Terminal RG-1000" Customer Programming Software

3 SmartPTT Radioserver settings

31

3. In the window that opens specify the parameters of the connection to the remote control station.

Active: Activates the connection to the remote control station. To disable the remote control station from the connection list, clear the Active check box. Name: Remote control station arbitrary name. Remote gateway IP address: Gateway network IP address. The IP address in this field must match the value specified in the settings of the gateway IP channel for this remote control station. See in RG-1000 CPS, the corresponding IP channel window in the Network section. XCMP port: The gateway port. The XCMP port in this field must match the value specified in the corresponding field in RG-1000 CPS. See the Port XCMP protocol field in the IP channel window of the Network section.

"Terminal RG-1000" Customer Programming Software

3 SmartPTT Radioserver settings

32

Local interface: The local interface used for connection to the RG-1000 GATEWAY. Radio ID: Unique identifier of the remote control station. Radio ID is to be set in the range from 1 to 16776415. CAI Network: CAI network identifier. To be set in the range from 1 to 126. Use the default value of 12. CAI Network for Groups: Group CAI network identifier. To be set in the range from 225 to 239. Use the default value of 225. Transmit Data Only: If selected, the remote control station is used for data transmit only and is not displayed in SmartPTT Dispatcher and is not available for voice calls. Allow Telephone Interconnect: Allows you to enable voice calls to telephone subscribers. GPS: Enables location service which provides coordinates of the subscribers, whose radios are equipped with a built-in GPS receiver. ARS: Enables registration service. When the radio powers up, the radio automatically registers with the server. Port 4005 is used as default. TMS: Enables the service for exchanging text messages between dispatchers and radio subscribers. Port 4007 is used by default. Telemetry Service: Enables the service responsible for transmitting and processing of telemetry signals between SmartPTT Dispatcher and subscriber stations. Port 4008 is used by default. Analog Call Hangtime: Virtual hangtime which is used for uniting analog calls into one. This was done to not overload the event log with too many records of analog calls. During this hangtime the channel is not reserved, anyone can start transmitting. The hangtime applies only if the remote control station is configured to operate in analog mode. GPS Transmission Mode: Allows you to select the way how to transmit location updates: as a data packet in multiple bursts or as a single CSBK (Control Signaling Block). This time select Data. Set local ports: Local ports that can be used for connection to the RG-1000 GATEWAY, if the default ports of the corresponding services are already in use. By default the system occupies local ports automatically, but you can define them manually.

"Terminal RG-1000" Customer Programming Software

3 SmartPTT Radioserver settings

33

4. Add or edit the channels of the remote control station in the Control Station Channels window. These settings allows remote switching between the control station channels and must match with the radio settings in the MOTOTRBO CPS.

Name: Channel alias visible to SmartPTT Dispatcher. Zone: Serial number of a channel group. Information on the maximum possible number of zones and radio station channels is shown in the following table. Model

Maximum number of zones

Maximum number of channels per zone

Maximum total number of channels

Mobile radio station with display

50

160

160

Mobile radio station with seven-segment display

2

32

32

Channel: Channel sequence number. : Selected channel will be set at the control station, when you start the radioserver. Copy: Copies added channels of the remote control station to the clipboard Paste: Pastes copied channels of the remote control station from the clipboard. Add: Adds a new channel. Remove: Deletes the channel from the list. To edit channel name, zone or channel number, place the cursor on the corresponding field and make changes. Note: The maximum number of zones and channels of the MOTOTRBO control station depends on the model and version of the parameter block.

"Terminal RG-1000" Customer Programming Software

3 SmartPTT Radioserver settings

34

5. In the Control Station Talkgroups window, add or edit the talkgroups, which the dispatcher(s) may use for making a call via the remote control station.

To add a talkgroup, click Add. To add All Call (is used in profiles), click All Calls. To change the order of groups in the list, use the Up and Down arrows. The order defined in the window will be used in SmartPTT Dispatcher. Name: Talkgroup alias displayed by the control station. ID: Talkgroup unique identifier used during communications. To be set in the range from 1 to 16776415. Copy: Copies added groups (their names and IDs) to the clipboard. Paste: Pastes copied groups from the clipboard. Remove: Deletes the selected talkgroup. To edit talkgroup name or ID, set the cursor on the corresponding field and make changes. 6. To select audio devices and set up VoIP parameters, click Audio in the setting tree of SmartPTT Radioserver Configurator. At that, the Audio Settings window will open.

"Terminal RG-1000" Customer Programming Software

3 SmartPTT Radioserver settings

35

The Active check box activates transmission and receiving of the audio signals for the remote control station. Codec: Outgoing audio stream compression method. The recommended value is CCITT u-Law. Format: Sampling frequency of an outgoing audio stream and the RTP packet size. The recommended value is 8000 Hz, 20 ms, 64 (86) kbps. 7. If you need to create more than one connection to the remote control stations, repeat steps 1 to 6 for each new remote control station.

3.2 Radioserver configuration to interact with the remote control stations in the Capacity Plus Legacy mode Radio network topology and the example of SmartPTT dispatching system for this radioserver configuration are described in details in the "RG-1000—Radio Remote Gateway" user guide. See the section "Example of system topology in the Capacity Plus Legacy trunking network". The parameters of the connection to the remote control stations in the Capacity Plus Legacy mode are configured in the Capacity Plus Systems section of SmartPTT Radioserver Configurator. This guide does not cover the common settings of the radio networks configuration. For more information about the Capacity Plus systems configuration see the "SmartPTT Radioserver Configurator" software help file. To add connection to the remote control stations in the Capacity Plus Legacy mode, configure the following settings the TX Stations menu item of SmartPTT Radioserver Configurator: 1. Right click TX Stations, then click Add > Remote MOTOTRBO control station.

2. Specify the parameters of connection to the remote control station as it is described in the previous section. 3. If you need to create more than one connection to the remote control stations, repeat steps 1 to 2 for each new remote control station.

"Terminal RG-1000" Customer Programming Software

3 SmartPTT Radioserver settings

36

3.3 Radioserver configuration to interact with the remote control stations in the NAI Capacity Plus and NAI Linked Capacity Plus hybrid modes Radio network topologies and examples of SmartPTT dispatching systems for this radioserver configuration are described in details in the "RG-1000—Radio Remote Gateway" user guide. See the following sections in the guide: · "Example of system topology in the Capacity Plus trunking network with data transmission via the NAI protocol (hybrid mode)", and · "Example of system topology in the Linked Capacity Plus trunking network with data transmission via the NAI protocol (hybrid mode)". The parameters of the connection to the remote control stations in the NAI Capacity Plus and NAI Linked Capacity Plus modes are configured in the corresponding sections in SmartPTT Radioserver Configurator. This guide does not cover the common settings of the radio networks configuration. For more information about the configuration of the NAI - Capacity Plus and NAI - Linked Capacity Plus systems see the "SmartPTT Radioserver Configurator" software help file.

"Terminal RG-1000" Customer Programming Software

3 SmartPTT Radioserver settings

37

To add connection to the remote control stations in the NAI Capacity Plus and NAI Linked Capacity Plus modes, configure the following settings in the NAI Systems section of SmartPTT Radioserver Configurator: 1. In the NAI - Capacity Plus or NAI - Linked Capacity Plus network general settings, select the Voice transmission check box and select Control Stations in list (applicable to the SmartPTT PLUS systems). If you use the SmartPTT Enterprise systems, skip this step.

"Terminal RG-1000" Customer Programming Software

3 SmartPTT Radioserver settings

38

2. In the Slot menu item of the NAI - Capacity Plus or NAI - Linked Capacity Plus sections, right click Control Stations, then click Add > Remote MOTOTRBO control station.

3. Specify the parameters of connection to the remote control station as it is described in the previous section. 4. If you need to create more than one connection to the remote control stations, repeat steps 1 to 2 for each new remote control station.

"Terminal RG-1000" Customer Programming Software

Appendix I Manual installation of RG-1000 GATEWAY's driver in Windows 8/8.1/10

39

Appendix I Manual installation of RG-1000 GATEWAY's driver in Windows 8/8.1/10 Before installing the RG-1000 GATEWAY's driver in Windows 8/8.1/10, you will need to disable the digital signature verification for the drivers. Note: The digital signature verification for the drivers is disabled only once (just for one Windows session). To disable the digital signature verification for the drivers in Windows 8/8.1/10 and then install the RG-1000 GATEWAY's driver manually, perform the following actions: 1. Click Run in the bottom left corner.

2. Click the Power management icon.

3. Holding the Shift key, click Restart. Wait, until a menu with restart options opens.

4. To configure the restart options, preform the following steps: · Click Troubleshoot in the Choose an option section.

"Terminal RG-1000" Customer Programming Software

Appendix I Manual installation of RG-1000 GATEWAY's driver in Windows 8/8.1/10

· Click Advanced options in the Troubleshoot section.

· Click Startup Settings in the Advanced options section.

"Terminal RG-1000" Customer Programming Software

40

Appendix I Manual installation of RG-1000 GATEWAY's driver in Windows 8/8.1/10

· Press F7 to select the Disable driver signature enforcement option for restart. Wait, until PC restarts.

5. After the computer restarts, open Device Manager (Control Panel > System > Device Manager).

"Terminal RG-1000" Customer Programming Software

41

Appendix I Manual installation of RG-1000 GATEWAY's driver in Windows 8/8.1/10

6. Find text string ATIS M-270A,right-click it and click Update Driver Software in the opened menu.

7. Click Browse my computer for driver software in the opened window.

"Terminal RG-1000" Customer Programming Software

42

Appendix I Manual installation of RG-1000 GATEWAY's driver in Windows 8/8.1/10

43

8. Specify the folder where the RG-1000 GATEWAY's driver is located and click Next.

9. If the folder contains correct driver software, the Windows Security notice opens. Click Install this driver software anyway.

"Terminal RG-1000" Customer Programming Software

Appendix I Manual installation of RG-1000 GATEWAY's driver in Windows 8/8.1/10

10. When the driver is successfully installed, the corresponding message appears.

"Terminal RG-1000" Customer Programming Software

44

View more...

Comments

Copyright ©2017 KUPDF Inc.
SUPPORT KUPDF