Corrosion Under Insulation

February 9, 2018 | Author: Ashfaq Anwer | Category: Corrosion, Steel, Thermal Insulation, Carbon, Steam
Share Embed Donate


Short Description

Download Corrosion Under Insulation...

Description

Corrosion Under Insulation A practical prevention guide as per API 570

All rights reserved to thepetrostreet.com

Moisture Sources W Water Leaks L k

Mist Spray from

Condensation

Cooling Towers

CUI

Deluge systems

Rains

Leaking Process fluids

All rights reserved to thepetrostreet.com

Common Forms

Localized Corrosion of Carbon Steel

All rights reserved to thepetrostreet.com

Chloride Stress Corrosion of Austenitic Stainless Steels

Susceptible Piping Systems

A Areas exposedd to

Mist of Cooling Towers

St Steam Vents V t

D l Systems Deluge S t

P Process SSpills ill

A id VVapors Acid

Carbon Steel Systems insulated for Human pprotection operating p g between -4 deg C – 120 deg C

Carbon Steel Systems operating above 240 deg d C with ith iintermittent t itt t service i

SSystems t where h operating ti temperatures t t cause frequent condensation and re-evaporation of atmospheric moisture

AAustenitic t iti SS systems t with ith operating ti Temperature between 65 deg C to 204 deg C (Chloride Stress Corrosion)

All rights reserved to thepetrostreet.com

Susceptible Piping Systems

Deadlegs and attachments protruding from insulation

Vibration systems with damaged Insulation and jacketing

Steam tracing systems with tracing leaks

S Systems withh ddeterioratedd coating andd wrapping

All rights reserved to thepetrostreet.com

Susceptible Common Locations

Penetrations/breaches in jacket

Damaged/missing jacketing

Hardened, separated, or missing caulking

Piping low points in systems that have insulation breach

Jacket seams on top of horizontal piping or improperly lapped/sealed jacket

Carbon or low-alloy steel components in high-alloy systems

All rights reserved to thepetrostreet.com

Susceptible Common Locations

Termination in insulation at flanges and other piping components

Termination of insulation in a vertical pipe

Bulges or staining of insulation or jacketing system (bulges may indicate corrosion products)

All rights reserved to thepetrostreet.com

Special Considerations

Insulation damage at higher elevations May cause CUI at lower elevations

Insulation removal, RT may be required

Expand inspection as necessary

Systems may be excluded: 1. 2 2.

All rights reserved to thepetrostreet.com

Remaining life > 10 years Ad Adequately l protectedd externally ll

Piping Service Classes

All rights reserved to thepetrostreet.com

Recommended Inspection Interval

All rights reserved to thepetrostreet.com

CUI Inspection Targets

All rights reserved to thepetrostreet.com

THANKS ‐ thePetroStreet team