SIMPLE DESIGN CHART & SAMPLE CALCULATIONS INDEX
DESIGN CONSIDERATIONS SIMPLE DESIGN LOAD AND SPAN CHARTS FOR CORCON
P2
SAMPLE CALCULATION
P6
BEAM DESIGN
P15
REFERENCE FIGURES FOR DESIGN
P24
Appendix IX. SIMPLE DESIGN CHART & SAMPLE CALCULATIONS
Created with novaPDF Printer (www.novaPDF.com)
P3
P1
CORCON Design, Construction and Technical Information Manual
DESIGN CONSIDERATIONS CORCON is a hybrid moltiribbed slab +beam system using the best properties of a slab coupled with all the advantages of the beam used to stiffen the slab in deflection. CORCON is a flexible system that can be applied to any span and loading configuration by the use of inserts which can be used to vary the depth of the CORCON rib beams - from a nominal 50 m2 depression to 300 m2 deep for extra heavy loads and or long Spam over 8 to 9m. Also by reducing the (c to c) centre to centre spacing from 1200 m2 and continuity the spam can be increased to 26m using post-tensioning. Small spans - say 3m- use CORCON with "FLAT" insert mould (see the Figure below):
If require structural primary beams could always use upstand beams subject to requirements. (see the Figure below):
This upstand systems allows continuous layting of CORCON ribs.
Appendix IX. SIMPLE DESIGN CHART & SAMPLE CALCULATIONS
Created with novaPDF Printer (www.novaPDF.com)
P2
CORCON Design, Construction and Technical Information Manual
SIMPLE DESIGN LOAD AND SPAN CHARTS FOR CORCON Beams @ 1200 Centres Single Span Allowable superimposed live load (KPa) Reqd Avg Conc C to C spans metres Beam bar Total . Depth size depth vol d mm overla mm 4.0 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 10.0 11.0 14.0 m3/ p m2* 50 2Y12 0.12 184 3 75 2Y12 0.12 209 5 .5^ 100 2Y12 0.12 234 5 1.5 150 2Y12 0.12 284 5 2.5 1 200 2Y12 0.12 334 4 4 2 1^ 250 2Y16 0.13 384 5 5 3.5 300 2Y16 0,14 414 5 5 1.5 hour fire rating, stc 49, min cover 85mm, f62 mesh top & 1/250 deflection * based on 20m2 room ^ roof loads ** post tensioned *** continuous post tensioned built in primary beam
2 4
0.3 3** 2 1^ 5** 3** 2***
Single Span Avg Total Allowable superimposed live load (KPa) Beam Reqd bar Conc. C to C spans metres Depth depth vol d mm size mm 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 overlap m3/m2* 50 2Y12 0.10 164 5 5 3 100 2Y12 0.10 214 5 150 2Y12 0.10 264 200 2Y12 0.11 314 250 2Y16 0.11 364 300 2Y16 0.12 414 0.5-hour fire rating, min cover 65mm, f62 mesh top & 1/250 deflection * based on 20m2 room ^ roof loads
1 4.5 2.5 .05 5 3.5 1.5 4 2 5
1
1 5 5
4 5
2 5
1.5 0.5 3.5 2 1
Continuous Span
Appendix IX. SIMPLE DESIGN CHART & SAMPLE CALCULATIONS
Created with novaPDF Printer (www.novaPDF.com)
P3
CORCON Design, Construction and Technical Information Manual
Beam Depth d mm
50
Allowable superimposed live load (KPa) and Reqd Avg Total deflection to span ratio. bar Conc. depth C to C spans metres size vol mm 10. 10. 11. overlap m3/m2* 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 0 5 0
2Y12
0.12*
2 184 1/2 70
75
2Y12
0.12*
209
100
2Y12
0.12*
234
150
2Y12
0.12*
284
200
2Y12
0.13*
334
250
2Y16
0.13*
384
300
2Y16
0.13*
2 1/2 75 2 1/3 00 2 1/2 75
434
2 1/2 75 2 2 1/3 1/3 50 00 2 2 2 1/3 1/3 1/2 50 00 50
1.5 hour fire rating, stc 49, min cover 85mm, f62 mesh & y16 @ 1200mm top
Appendix IX. SIMPLE DESIGN CHART & SAMPLE CALCULATIONS
Created with novaPDF Printer (www.novaPDF.com)
P4
CORCON Design, Construction and Technical Information Manual
SELECTED SECTION PROPERTIES B
d D
b= B= D= d= Fck = Fy = Conc. Cover = Rib Spacing =
110mm 155Mm 485mm 300mm 30N/mm2 460N/mm2 25mm 900mm
Cross sectional Area = 177954.57mm2 Moment of Inertia Ixx = 2468.22E6 mm4 Reinforcement at Mid-Span = 2 * T16 mm Dia. Reinforcement at Supports = 3 T 12mm Dia. Moment Capacity at Mid Span = 69.08KN-m Section Capacity at Support = 81.03 Actual Deflection = 1.14mm Shear Capacity = 0.86N/Sq.mm Shear Reinforcement = Please check CORCON test Results. Concrete Volume per Sq.m of Plan Area = 0.15Cub.m Reinforcement per Sq.m of Plan Area = 0.26Kg
Appendix IX. SIMPLE DESIGN CHART & SAMPLE CALCULATIONS
Created with novaPDF Printer (www.novaPDF.com)
P5
CORCON Design, Construction and Technical Information Manual
SAMPLE CALCULATION PROJECT
JOB REF
The Sukhothai Bangkok DECOIN PTY LTD ACN 008 625 590 ABN 30 008 625 590
CALCULATION BY Upul Perera PART OF STRUCTURE
Appendix IX. SIMPLE DESIGN CHART & SAMPLE CALCULATIONS
Created with novaPDF Printer (www.novaPDF.com)
CHECKED BY
CALC SHEET
PRINTED BY Decoin Pty Ltd
DATE 09/02/2003
P6
CORCON Design, Construction and Technical Information Manual
MEMBER REF
LOAD CALCULATIONS
OUT PUT
Loading (Guest Room Area) (A) Rib Self weight kN/m2 Screed + Finishes kN/m2 Services kN/m2 Ceilings kN/m2
= 3.36 = 1.177 = 0.225 = 0.225
References to BS 8110
Partitions
=
kN/m2 - DL Imposed Lead kN/m2 - LL
3.434 8.421
1.962
n= 14.93 kN/m2 Udl for Ribs
(ult)
DL = 8.421 x 1.2 = 10.1 kN/m LL = 1.962 x 1.2 = 2.4 kN/m
(B) Plant Room Area Rib Self wt. Screed
= 3.36 = 1.1772 0.225 = 4.7622
Services
kN/m2
- DL Live Leads kN/m2 - LL
= 7.35 8
N= 18.439 kN/m2 (ULT) Udl for Ribs
(C )
Storage Room, Rib self wt. Screed Services
kN/m2 - DL Imposed Load 2 kN/m - LL
DL = 5.715 kN/m LL = 8.829 kN/m = 3.36 kN/m2 = 1.177 0.225 = 4.7622
Appendix IX. SIMPLE DESIGN CHART & SAMPLE CALCULATIONS
Created with novaPDF Printer (www.novaPDF.com)
4.905
-
P7
CORCON Design, Construction and Technical Information Manual
UDL for Ribs, MEMBER REF
DL = 5.715 kN/m LL = 5.886 kN/m
Specimen Calculation Y20
OUT PUT
Y20 125 Area=140561 mm2 = 0.14 m2
400
66
References to BS 8110
Loading for [live load of 300 kg/m2 Area] Ribbed slab self wt = 0.14 x 24 = 3.36 kN/m2 Screed = 1.18 Services = 0.225 Ceilings = 0.225 4.99 kN/m2 – DL = 2.943 kN/m2 -
Live Load LL Design Ultimate Load x 1.6
n = 4.99 x 1.4 + 2.943 = 11.69 kN/m2
Uniformly Distributed Load on a Rib DL = 1.2 x 4.99 = 5.88 kN/m LL = 1.2 x 2.943 = 3.53 kN/m (service load) Three load combinations were considered. Please refer Prokon print out sheets #01 to #03. The rib beam is designed for max. sagging and hogging moment for each span, considering BM and SF envelopes.
MEMBER REF
CALCULATIONS
OUT PUT
A. Durability and Fire Resistance of Rib Slab BS8110 Cl 3.3.4
Exposure conditions: It is assumed that these rib beams are used in areas where the concrete surfaces are protected
Appendix IX. SIMPLE DESIGN CHART & SAMPLE CALCULATIONS
Created with novaPDF Printer (www.novaPDF.com)
P8
CORCON Design, Construction and Technical Information Manual
against weather or aggressive conditions. Therefore treat as mild Exposure Conditions. BS8110 Table 3.4
For Grade 30 Concrete (30 Mpa) the Nominal cover requirement is as 25 mm, for Durability requirement, Note: Above cover requirement is including links
BS 8110 Table 3.5
Nominal cover for Ribbed slab for : 01 hr. Fire Period = 20 mm 02 hr. Fire Period = 35 mm for continuous beams 45 mm for Simply Supported beams
use 35 mm cover for bottom bars BS 8110 Fig. 3.2
Minimum member Dimensions regeared for Ribbed beams, is 125 mm and Slab thickness of 95 mm for 1 hr fire rating? Same for 2-hr fire rating is 125 mm ribs & 125 mm slab thickness.
MEMBER REF
CALCULATIONS
OUT PUT
Design for bending. MaxM + re moment in the span = 71.1 kNm. BS 8110 Cl.3.4.4.4
Effective Depth (d) = 400 – (35+6+15) = 344 mm
Appendix IX. SIMPLE DESIGN CHART & SAMPLE CALCULATIONS
Created with novaPDF Printer (www.novaPDF.com)
P9
CORCON Design, Construction and Technical Information Manual
K=
M 71.1 10 6 =0.017 < k’ = 0.156 bd 2 f cu 1179 344 2 30
Hence Compression R/F is not required. Z=d [0.5 +
k 0.25 ] < 0.95d 0.9
0.017 =344 x [0.5+ 0.25 ] 0.9 =344 x 0.98 >0.95d Z=0.95d=0.95x344=327mm
Depth to Neutral axis ‘x’ = (d-z)/0.45 =(344-327)/0.45 =37.8mm k’=0.156 66 334 2 30
Compression Steel is required.
Z=d [0.5 +
k' 0.25 ] 0.9
= 334[0.5 +
0.156 0.25 ] 0.9
= 334 x 0.776 = 259 mm x= (d-z)/0.45 = (384-259) / 0.45 = 166.6 mm Area of compression Reinforcements: A's=(k-k') fcubd 2/0.87 fy(d-d') 0.285 0.15630 66 334 2 = =261.8 mm2 0.87 450 334 56 Area of tension R/F : As = k' fcu bd2 / 0.87fyz +A's 0.156 30 66 334 2 As = +261.8 = 601.6 mm2 0.87 450 259
Compression steel area at support A's = 261.8 mm2
Tension steel area at support As = 601.6mm2
100 Asmin . =0.26 bwh 0.26 95.5 400 Asmin. = = 99.3 mm2 actual span 7,258 mm
Hence: Deflection is satisfactory.
Appendix IX. SIMPLE DESIGN CHART & SAMPLE CALCULATIONS
Created with novaPDF Printer (www.novaPDF.com)
P13
CORCON Design, Construction and Technical Information Manual
CHECK FOR DEFLECTION (BS8110) DATA Bending moment at mid span =
114 kNm (Ultimate)
Average web width
(b w) =
95.5 mm
Effective Flange width
(b) =
1179 mm
Effective depth at mid span (d) =
394 mm
Actual span of rib
=
7525 mm
Strength of reinforcement (fy)
=
450 N/mm
Area of steel required (Asreq.) =
778 mm
2
Area of steel provided (Aspro.) =
805 mm
2
Moment redisribution ratio
=
1
=
16.76
2
CALCULATIONS Basic Span/Span Depth ratio
The design service stress (fs) = Modification factor
=
Allowable Span
=
271.82 N/mm
2
1.67 11,046
1.673 mm
Deflection is Satisfactory
Table 3.10 of BS8110 See the BS 8110- Table 3.10
b w/b =
0.1
Rectangular Support Conditions Sections
Flanged Beams with bw/b
View more...